Next Article in Journal
Digital Image Correlation for Measuring Full-Field Residual Stresses in Wire and Arc Additive Manufactured Components
Previous Article in Journal
Properties Evaluations of Topology Optimized Functionally Graded Lattice Structures Fabricated by Selective Laser Melting
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Electric Cable Construction Parameter and Its Potential to Foresee the Cable Fire Properties

by
Katarzyna Kaczorek-Chrobak
* and
Jadwiga Fangrat
*
Fire Research Department, Instytut Techniki Budowlanej, Filtrowa 1, 00-611 Warszawa, Poland
*
Authors to whom correspondence should be addressed.
Materials 2023, 16(4), 1689; https://doi.org/10.3390/ma16041689
Submission received: 5 October 2022 / Revised: 7 February 2023 / Accepted: 14 February 2023 / Published: 17 February 2023
(This article belongs to the Section Construction and Building Materials)

Abstract

A cable parameter related to the volume of effective non-combustible content, Ω, is proposed, which depends on the ratio of non-metallic, non-combustible component volume to non-metallic, combustible component volume, and the effective area of heat transfer within the cable during the combustion process. The correctness of the proposed cable parameter for circular cables is confirmed by tests and the determination of Spearman’s correlation. High Spearman’s correlation factors (close to −1) were obtained for total heat release and total smoke production as a function of the Ω cable parameter. The Ω cable parameter might be used in selecting cable samples for large geometric-scale fire testing within the same cable family.
Keywords: cable parameter; cable fire properties; reaction to fire of cables; fire safety cable parameter; cable fire properties; reaction to fire of cables; fire safety

Share and Cite

MDPI and ACS Style

Kaczorek-Chrobak, K.; Fangrat, J. Electric Cable Construction Parameter and Its Potential to Foresee the Cable Fire Properties. Materials 2023, 16, 1689. https://doi.org/10.3390/ma16041689

AMA Style

Kaczorek-Chrobak K, Fangrat J. Electric Cable Construction Parameter and Its Potential to Foresee the Cable Fire Properties. Materials. 2023; 16(4):1689. https://doi.org/10.3390/ma16041689

Chicago/Turabian Style

Kaczorek-Chrobak, Katarzyna, and Jadwiga Fangrat. 2023. "Electric Cable Construction Parameter and Its Potential to Foresee the Cable Fire Properties" Materials 16, no. 4: 1689. https://doi.org/10.3390/ma16041689

APA Style

Kaczorek-Chrobak, K., & Fangrat, J. (2023). Electric Cable Construction Parameter and Its Potential to Foresee the Cable Fire Properties. Materials, 16(4), 1689. https://doi.org/10.3390/ma16041689

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop