Compilation of a Prediction-Based Validation Dataset for Heat Transfer Modeling of the Paks Spent Fuel Interim Storage Facility

and
1
Doctoral School of Applied Informatics and Applied Mathematics, Obuda University, 1034 Budapest, Hungary
2
EVIG Engineering Co., Ltd., 1103 Budapest, Hungary
3
Department of Natural Science, Institute of Electrophysics, Kando Kalman Faculty of Electrical Engineering, Obuda University, 1034 Budapest, Hungary
*
Authors to whom correspondence should be addressed.

Abstract

This study presents and systematizes a high-reliability measurement and technological dataset suitable for prediction-based validation of the Spent Fuel Interim Storage Facility (SFISF) of the Paks Nuclear Power Plant. The primary objective of this dataset is not the validation of a general-purpose software tool, but to establish a reproducible experimental basis for the objective and quantitative validation of a three-dimensional, facility-scale heat transfer and buoyancy-driven flow model of the SFISF, developed using the finite difference method (FDM), in a passively cooled system where heat conduction, thermal radiation, and natural convection simultaneously occur. The applied measurement systems (SMAS, CTRS, and the in-house developed CFEPR), their spatial arrangement, accuracy characteristics, as well as data post-processing and the generation of model execution inputs are described in detail. Special emphasis is placed on the functional separation of the available data into initialization data, model execution data, and independent validation datasets, ensuring that model assessment does not rely on calibration or parameter fitting. Furthermore, the estimation of decay heat generated by the stored fuel assemblies is presented using both a standard correlation method (ANSI/ANS-5.1) and isotope inventory-based calculations, and the discrepancies between these approaches are treated as input uncertainties and sensitivity analysis factors. The spectral solar load is considered based on the ASTM G-173 reference spectrum, while during cloudy periods an effective irradiance estimation derived from on-site lux measurements is applied. The results indicate that the available measurement and technological information is sufficient for supporting reproducible, transparent, and quantitative validation studies of the three-dimensional numerical model of the SFISF, as well as for assessing the impact of dominant input uncertainties.

1. Introduction

Due to past nuclear accidents, public perception of nuclear energy is often characterized by fear and concern. People question whether nuclear power plants are sufficiently safe and whether the industry is capable of properly managing spent nuclear fuel and radiation-contaminated equipment. The nuclear industry, however, does not underestimate the inherent hazards of nuclear energy. On the contrary, the use of nuclear energy is subject to the strictest regulatory and supervisory frameworks at both international and national levels.
For both newly designed and existing facilities and systems, national nuclear authorities require comprehensive pre-design studies and the demonstration of operational safety already during the design phase. A primary requirement in this process is to guarantee that radioactive isotopes cannot be released into the environment, while simultaneously ensuring that the collective radiation dose to the public and operating personnel is kept as low as reasonably achievable (ALARA principle). Engineering design activities are therefore accompanied by detailed studies that, in almost all cases, rely on numerical simulations.
High-accuracy numerical analyses in the nuclear industry have traditionally involved complex and time-consuming manual calculations. With the advent of digital computing, these calculations have been automated through software tools; nevertheless, they remain computationally intensive and time-demanding tasks. Typical examples include fuel burnup calculations, reactor power distribution and optimization analyses, and the determination of cooling capacities for spent fuel storage systems.
Within the framework of our research, a self-developed three-dimensional heat transport modeling software based on the finite difference method (FDM) has been developed to support nuclear engineering design activities. This software is capable of simulating the coupled physical phenomena of heat conduction, thermal radiation, and convection, including both naturally induced and forced flows, within a three-dimensional computational domain.
The primary objective of the present study is to present a high-quality experimental dataset that establishes the experimental and technological basis for the future validation of the thermal and flow model developed for the Hungarian Spent Fuel Interim Storage Facility (SFISF). The validation is based on in-situ measurements performed directly on the facility, with the aim of obtaining a software-based representation of the spent fuel cooling technology at Paks that is characterized by high reliability and quantified numerical uncertainty. The present paper focuses on data compilation, documentation, and structuring, while the detailed quantitative validation and performance assessment will be presented in subsequent publications.
As a longer-term benefit of the research, two main outcomes are anticipated. First, the model, once validated, is expected to provide a reliable and uncertainty-aware computational tool for future calculations related to the expansion of the SFISF and for subsequent safety reviews. The intention is not to replace the currently applied finite volume method (FVM) model, which has not been validated against measurements, but rather to provide a parallel and methodologically independent computational approach to support regulatory safety demonstrations. In safety assessment procedures, it is often a formal requirement that conclusions are not based on a single computational method; therefore, the validated FDM-based building model presented here can supply additional confirmatory results alongside the existing FVM model.
Second, the present study, together with subsequent publications that will present model execution results and their quantitative comparison with measurement data, may serve as a methodological reference for the validation of thermal models of other existing or newly designed dry storage facilities.
In general terms, in computer science, the purpose of validation is to examine whether a numerical model describes the real physical system with adequate accuracy. In the demonstration of software and model operations and the quality of their performance, two main stages are typically distinguished [1,2,3,4,5]: (1) verification, aimed at checking the correctness of the numerical solution and its implementation; and (2) validation, based on comparison with high-reliability experimental measurements.
The verification of our software has already been partially carried out in our heat conduction publication [6]; however, the flow-related components, including convective flow, as well as our thermal radiation solution, will be published at a later stage, in parallel with simulation campaigns.
In the following, in order to implement a consistent and reproducible validation framework in the course of our research, the available data are clearly separated according to their role in the modeling and validation process. The complete available dataset is divided into initialization data, model execution data, and independent validation data. Each data group contains measurements obtained on the selected reference system for validation, as well as mechanical, design, and engineering parameters derived from the mechanical configuration. The initialization and model execution data serve exclusively to define the initial and boundary conditions of the numerical model, while the validation data are used exclusively for the future evaluation of model accuracy.
The separation of the datasets in this manner enables the future application of a prediction-based validation approach. In this approach, the evaluation of the numerical model is performed on the basis of experimental measurements that do not participate in either the calibration of the model or the fitting of model parameters. At a later stage, the comparison between the model results and the measurement data will be carried out in a quantitative manner, and—where possible—both measurement and numerical uncertainties will be taken into account, thereby allowing the model accuracy to be assessed in an objective way [7,8].
The selected reference system is the Spent Fuel Interim Storage Facility (hereinafter referred to as SFISF) operating at Paks, which serves for the interim dry storage of spent nuclear fuel discharged from the nuclear power plant [9,10,11]. The building consists of so-called modules, and the modules are further subdivided into chambers. Depending on their type (and the date of the build), each chamber contains 450, 527, or 703 individual storage tubes into which the spent fuel assemblies are placed. The system has been architecturally designed in such a way that the storage tubes are cooled in a completely passive manner by the naturally flowing air between them, utilizing the principle of the chimney effect (otherwise known as stack effect). A side-view layout of one storage chamber of the SFISF is shown in Figure 1. The figure illustratively presents the flow path of the air circulating inside the building.
Figure 1. Cross-sectional schematic of the conceptual layout of the storage chambers of the Spent Fuel Interim Storage Facility (SFISF), clearly illustrating the airflow path.
The architectural and cooling design of the SFISF is unique. Although similar passively cooled storage concepts exist, they are not identical to the system implemented at the Paks site. Consequently, the thermal analysis of the facility, the development of its numerical model, and its quantitative validation constitute a case-specific and non-transferable research task.
The data required for the future validation of the thermal model of the SFISF can be divided into two parts according to their source: measurement data and technological parameters. The provided datasets can also be further classified according to their use, distinguishing between model initialization parameters, model execution data (e.g., measured time-dependent boundary conditions), and data used for the validation of the model results. In the following sections, the data considered necessary for validation are listed and grouped, and the methods applied for the post-processing of the measurement results are presented.

2. Technological Parameters

2.1. Model Parameters and Boundary Conditions

In the present modeling task, the technological parameters comprise two elements: architectural data and the heat power of the heat sources; i.e., the heat generation rates of the individual spent fuel assemblies. With regard to the architectural data, it can generally be stated that all major elements required for the construction of the three-dimensional model—such as the reinforced concrete structures, the roof, the storage tubes, the steel support grids, the collimators, and the fuel assemblies—together with their architectural and mechanical design drawings, including dimensions and material specifications, were available to us.
A graphical representation of the three-dimensional model assembled from these data is shown in Figure 2, where different colors are used to indicate different material properties.
Figure 2. Three-dimensional building model of storage chamber 21 of the Spent Fuel Interim Storage Facility. The model is geometrically identical to the actual building section; i.e., it is constructed at a 1:1 scale.
In Figure 2, it may appear that the top of the chimney is “floating in the air”; i.e., it not supported by any structure. This is, however, merely a visual artifact resulting from the intentional simplification of the three-dimensional model. In order to reduce model complexity, components that do not influence—or only negligibly influence—the behavior of the heat transport processes were omitted from the model.
Among the omitted elements is, for example, the steel structure supporting the roof at the chimney, which serves a purely load-bearing function. If this steel structure were included in the model, it would be expected to affect only the local temperature distribution in the upper part of the chimney, owing to the high thermal conductivity of steel. From the perspective of model validation and operation, the primary quantities of interest are the characteristics of the air flow—including velocity and temperature—and the temperatures of the storage tubes containing the spent fuel assemblies, as well as the concrete structures located directly adjacent to them.
In addition, among the larger components, the wildlife protection grilles located at the air inlet openings were also neglected and therefore omitted from the model. These grilles are expected—due to their low density—not to affect, or only to a very limited extent, the flow pattern at the air inlet openings.
The three-dimensional building model shown in Figure 2 is imported into our CHeTMoS software (internal version v0.3, November 2025 build). The numerical model represents a 1:1 geometric mapping of the real facility. For legal and security reasons, the exact dimensions of the structure cannot be disclosed; therefore, only the overall extents of the reinforced concrete structure along the principal axes of the Cartesian coordinate system are provided, as indicated in Figure 2.
The effective airflow cross-section at the inlet is 5.654 m 2 ( 0.992 m × 5.700 m ), while at the outlet it is 6.27 m 2 ( 1.100 m × 5.700 m ). Consequently, the air velocity at the outlet is expected to be lower than that at the inlet due to the increased cross-sectional area.
In finite-difference-method (FDM)-based numerical models, spatial and temporal resolution are governed by the spatial discretization step and the time step, respectively. When explicit time integration is applied, numerical stability is constrained by a stability criterion that depends on the material properties—such as thermal conductivity, density, and specific heat capacity—as well as on the spatial and temporal discretization parameters. This stability criterion is upper bounded, and numerical stability can only be ensured if the discretization parameters do not exceed this limit.
In the present study, the model time step is fixed to a one-minute resolution, consistent with the available measurement data. Under this constraint, numerical stability can only be ensured through the appropriate selection of the spatial grid spacing. In general, the Courant–Friedrichs–Lewy (CFL) condition is widely accepted for controlling numerical stability, as compliance with the CFL condition guarantees stable temporal evolution of the computed numerical values.
For the development of the SFISF model, however, a stricter, internally defined stability criterion is applied for grid resolution selection. This criterion, previously introduced in our earlier publication as the No-Sway threshold, imposes a more restrictive condition than the classical CFL criterion. Its application has already been demonstrated to ensure that the temporal evolution of temperature remains strictly monotonic in all cases, in contrast to the CFL condition, under which oscillatory—but damped—temperature fluctuations may occur. Such oscillatory behavior is typically observed when model parameters are selected close to the stability limit. By applying the No-Sway threshold, a more physically realistic temperature distribution is expected in both solid and gaseous domains.
A uniform spatial discretization step is applied throughout the entire computational domain; thus, the grid spacing is constant everywhere. As a consequence, all grid elements appear cubical, and their effective size may be larger or smaller than the corresponding physical geometry due to discretization-induced rounding. To account for this effect at material interfaces (solid–solid and solid–gas), a mass-weighting approach is applied. In this method, grid cells retain identical geometric dimensions, while their mass is adjusted to match the actual amount of material present.
More specifically, if a material interface between materials k and l is located within a given grid cell, the cell (A) is initialized using the material occupying the larger volume fraction. The mass of cell A is then scaled according to its physical occupancy, such that m A = n · m l , n < 1 . For the adjacent cell (B), the contribution of material l present in cell A is taken into account, resulting in a mass of m B = ( 1 + ( 1 − n ) ) · m k . The boundary conditions applied in the model are classified into three groups: heat transfer boundary conditions, flow boundary conditions, and radiative boundary conditions. For both solid and gaseous materials, numerically open boundary conditions are applied, whereby the medium beyond the computational domain is implicitly assumed to continue with identical material properties. Consequently, both conductive heat transfer and flow transport processes are allowed across the model boundaries. At all domain boundaries, the material on the boundary matches the implicitly assumed external medium, resulting in concrete–concrete and air–air transitions at the domain limits.
With respect to heat transport, the following boundary conditions are applied in the model: heat conduction occurs between solid–solid and solid–gas materials; convective flows develop within the gaseous domains; and thermal radiation occurs exclusively between solid surfaces treated as gray bodies, while the air is considered perfectly transparent and radiatively non-participating. Accordingly, heat transfer between materials of different phases (solid–gas) is not prescribed through fixed temperatures, but is governed by heat transfer mechanisms dependent on the local air state.
The primary flow-related boundary condition is that convective motion within the model is driven by temperature differences between different locations in the gaseous domain. The resulting three-dimensional local flow vectors are computed using a finite-difference formulation derived from the Navier–Stokes equations. The actual gas motion, that is, the spatial displacement of gaseous elements, is represented through advection along the locally computed flow vectors on the three-dimensional grid. This approach can therefore be interpreted as a buoyancy-driven flow model based on a finite-difference approximation of the Navier–Stokes equations. Accordingly, the airflow primarily develops between the storage tubes, and it affects the entire internal flow domain of the facility as well as certain regions of the surrounding free space. Accordingly, from the perspective of the model behavior, the airflow patterns of primary importance and interest develop mainly between the storage tubes. Although airflow also occurs in the space above the loading deck, its behavior is not relevant to the present analysis and is therefore not addressed in detail.
At the inlet boundary, air temperature, relative humidity, and pressure are prescribed as time-dependent, measurement-based values, thereby implementing a time-dependent Dirichlet boundary condition. In contrast, the outlet boundary is treated as a pressure-controlled open boundary, with neither velocity nor mass flow explicitly prescribed. Under the assumption of an infinite external domain, air exiting the model at any boundary location is replaced by air whose properties are defined by the time-dependent measured model execution data.
For radiative boundary conditions, the fundamental assumption is that thermal radiation occurs exclusively between solid surfaces, while the emissive and absorptive properties of air are neglected. Accordingly, the gaseous medium is treated as radiatively transparent. Solid surfaces in the model are not defined as ideal black bodies; instead, material-specific emissivity and absorptivity values are assigned. Solar radiation is also considered as an external, time-dependent radiative load. Its magnitude is determined partly from measurement data and partly from the incidence angle derived from the Earth–Sun geometric configuration, together with the corresponding spectral irradiance.
Solar radiation is expected to primarily affect the air temperature in the enclosed space above the loading deck, while its influence on the temperatures of the storage tubes and the flowing air is considered negligible. To verify this assumption, a dedicated analysis is conducted in parallel with the validation process, in which the effect of solar radiation as a thermal contribution is evaluated for both the storage tubes and the airflow through the building. In this analysis, fuel assemblies with zero heat generation are assumed, and the calculated inlet and outlet air temperatures are compared. Excluding fuel heat generation from this investigation provides insight into the intrinsic cooling capability of the building and supports the quantification of numerical uncertainty arising from the solar radiation and cloud-cover approximations applied in the heat transport model.

2.2. Heat Generation Due to Radioactive Decay

As mentioned earlier, the technological parameters also include the thermal power data of the spent nuclear fuel. From the operator, the Public Limited Company for Radioactive Waste Management (hereinafter referred to, according to its official abbreviation, as PURAM), we received the delivery data of the fuel assemblies loaded into the two investigated chambers, provided in separate files and broken down by individual transport containers. These files contain data previously generated and transferred by the Paks Nuclear Power Plant, which were minimally sufficient for obtaining the authorization for transferring the fuel assemblies to the SFISF and for their registration in the PURAM database.
Based on the transport data, we compiled the complete fuel inventory data for storage chamber 12 and storage chamber 21. Table 1 presents, through several examples, the intermediate database derived from the received files. For security reasons, data critical for the identification of individual fuel assemblies were modified. The unique identifiers were removed, and data related to loading into the SFISF (such as the start of storage and storage coordinates) were also altered.
Table 1. Fuel lifecycle data.
Columns of Table 1 contain the fuel assembly type (Column 2), the date of loading of the fuel assembly into the reactor (Column 3), the durations of the individual irradiation cycles (Columns 4–7), the known average burnup value (Column 8), the date of final discharge from the reactor (Column 9), the duration of cooling in the spent fuel pool at the power plant (Column 10), the date of transfer to the SFISF (Column 11), the exact storage position within the SFISF (Column 12), and finally the residual heat power of the fuel assembly at the time of transfer to the SFISF (Column 13).
It should be noted that the term residual heat is used to refer to the resulting heat power assigned to a fuel assembly at a given time and used as input to the thermal model. In the present study, residual heat is entirely determined from calculated decay heat by the authors.
The main stages of the fuel assemblies’ life cycle are known; however, the residual heat power provided corresponds only to the value at the time of loading into the SFISF. Considering that up to 18 years may have elapsed between the time of storage and the present investigation, the actual heat power in the storage chambers differ due to the decay of short- and medium-lived isotopes.
For these reasons, in order to refine the input data of the three-dimensional heat transport model, it was considered necessary to determine the temporal evolution of the decay heat of the individual fuel assemblies. Several approaches are available for calculating the residual heat power corresponding to the conditions observed during the measurement period. In engineering practice, a commonly applied method is the standard correlation approach, in which empirical or semi-empirical correlations are used to determine the residual heat power of a spent fuel assembly based on its irradiation history. One of the most widely used examples is the ANSI/ANS-5.1 calculation procedure [12,13] applied for LWRs. Its main advantage is computational efficiency; however, due to its empirical nature, it does not represent a physically explicit model, and its accuracy may vary depending on the specific fuel history.
More accurate results can be obtained using isotope inventory-based depletion and decay codes, which explicitly track the nuclide generation during irradiation on a cycle-by-cycle basis and calculate the radioactive decay of the isotopes during cooling and storage periods. Compared to standard correlation methods, this approach requires significantly higher computational resources but yields more accurate results due to the use of fuel-assembly-specific isotopic inventories. Such isotope inventory-based solutions include ORIGEN [14,15], Serpent [16], and OpenMC [17]. Additional approaches are provided by lattice and core physics codes, which are primarily used for accurate modeling of neutron physics states, from which residual heat can be derived indirectly. Examples of such lattice and core physics codes include CASMO [18,19], HELIOS [20], DRAGON [21], and SIMULATE [22,23].
Inventory- and activation-focused codes, libraries, and programs primarily aim at determining isotopic inventories, activities, and radiation source parameters—such as flux and spectrum. This group includes tools such as FISPACT-II [24,25], DARWIN [26,27], and ACAB [28,29].
The criteria for selecting among the above-described options were as follows: ease of use, including the ability to provide relevant data without reliance on additional external codes or programs; the capability to run on a personal computer while delivering results within a reasonable time; and, most importantly for our purposes, availability free of charge for educational and research applications. Based on these criteria, the range of applicable methods was narrowed down to two options: the ANSI/ANS-5.1 correlation method and the OpenMC software library. (Other programs are also available free of charge for education institutions; however, their use is subject to registration and personnel screening, which would have introduced delays to the research).
For the determination of the residual heat power, as a first approximation, the equations and coefficients defined by ANSI/ANS-5.1 were applied and implemented in our developed C# code. The equations fitted to the available data are summarized in Appendix A of the present publication. Throughout the calculation, it was taken into account that, for all irradiation cycles, only a single average burnup value is available for each fuel assembly. Since the durations of the maintenance outages between irradiation cycles are not known, the time intervals between loading and cooling were partitioned into equal-length segments by considering the total number of days elapsed and the total irradiation time, and these were distributed uniformly among the cycles.
Subsequently, in order to calculate the residual heat power with sufficient accuracy, it was necessary to know the initial uranium mass contained in the fuel assemblies; however, this information was not included in the source data received from PURAM. The uranium content by fuel type was obtained from publicly available sources [30] (the Austrian Federal Environment Agency, Umweltbundesamt—UBA), and the relevant values used in our calculations are summarized in the table provided in Appendix B. Using our software, the heat power values were calculated with daily resolution over a time span of 50 years. It should be noted that such a 50-year time series is not required for the validation of the heat transport model; however, anticipating future modeling tasks, these data were generated already at this stage.
In parallel with the above work, we developed our own Python-based program utilizing the OpenMC code, in which two different modeling approaches were implemented: a simplified and a more complex fuel assembly representation. The purpose of this dual approach was to investigate the effect of geometrical detail on computational requirements, with the expectation that the more detailed model would demand increased computational resources. Both approaches aim to determine the complete irradiation history and global isotopic composition of the fuel assemblies using different levels of geometric resolution, thereby enabling mutual verification and validation of the results.
In the simplified pellet stack model, the entire fuel assembly is represented as a single continuous uranium dioxide cylinder, assuming axially and radially homogeneous fuel distribution. The model does not explicitly include the cladding, assembly structure, or inter-rod spaces; instead, the fuel is treated as an effective volume. The pellet stack volume is determined from the total uranium mass obtained from tabulated operational data and the density of UO 2 , ensuring mass balance consistency. The geometry is embedded in a water moderator environment and bounded by vacuum or reflective boundary conditions, which limit artificial neutron leakage. This approach describes the average neutronic behavior of the assembly and primarily provides a fast and computationally efficient estimate of the total isotopic inventory and decay heat.
In contrast, the detailed assembly model explicitly represents the full cross-sectional geometry of a VVER-440 fuel assembly. The model includes 126 fuel rods arranged in a hexagonal lattice, along with the central instrumentation tube (Zr-1%Nb), cladding (Zr-2.5%Nb), and moderator regions. Each fuel rod is subdivided into separate fuel, cladding, and moderator regions, allowing for a detailed calculation of the spatial neutron flux distribution and the resulting reaction rates. Lateral reflective boundary conditions are applied to approximate an infinite lattice, thereby implicitly accounting for the influence of neighboring assemblies. Axial reflective or closed boundaries are used to minimize global neutron leakage.
For both models, the total fuel mass and enrichment are determined from available operational data. The average assembly power is introduced as an effective constant value calculated from the specified burnup (MWd/kgU), uranium mass, and total irradiation time. The irradiation history is constructed from the durations of reactor cycles and the intervening shutdown periods, during which the power is set to zero. The maintenance periods between cycles are assumed to be of equal length. Neutron transport and fuel depletion are calculated using the coupled transport–depletion method implemented in OpenMC, which updates reaction rates and isotopic compositions at each time step.
Decay heat was evaluated at three characteristic time points: immediately after reactor shutdown, at the time of loading into the spent fuel interim storage facility (SFISF), and at the time of the reference measurement. To reduce computational effort, the number of evaluated time points was limited to these three selected dates. This approach provided sufficient data for comparing the different fuel assembly models. Table 2 presents a comparison of the decay heat values obtained for five fuel assemblies per storage chamber using the three modeling approaches discussed above.
Table 2. Comparison of decay heat values obtained with different approaches.
An examination of Table 2 shows that, relative to the reference values, all approaches yield results that are partly consistent, while significant deviations can also be observed. For example, in the case of fuel assembly No. 1, the difference in thermal power reaches the order of tens of watts. In this case, the reference value is higher than the values obtained from all applied models.
Another important observation is that fuel assemblies No. 8 and No. 9 were assigned identical irradiation cycle lengths and burnup values; however, the date of loading into the reactor is earlier for fuel assembly No. 8. As a consequence of estimating the maintenance outage durations between irradiation cycles, small deviations appear in the calculated heat power values for all of our models. It is likely that the reactor was loaded with fuel assemblies in two separate campaigns and was only started up after completion of the second campaign. Within the applied models, the approximately three-month difference between the reactor loading dates resulted in some deviation between the residual heat powers of fuel assemblies with identical burnup values; however, due to the small magnitude of this effect, the deviation can be considered negligible.
Based solely on the dataset received from PURAM and available to us, it is difficult to determine which model result is closer to reality. This is because the quality and origin of the PURAM data source are not fully known for us. However, from the presence of identical data values within this dataset, it can be inferred that these values are not derived from measurements but are calculated. This conclusion follows from the fact that even for fuel assemblies with identical enrichment, some level of variation in residual heat power should be expected, as minor manufacturing differences, reactor control non-uniformities, and the residual heat of neighboring spent fuel assemblies would lead to larger differences in the resulting residual heat power. A quantitative evaluation of Table 2 indicates that, relative to the ANSI/ANS-5.1 results, the OpenMC pellet-level model deviates typically within approximately ± 5 % at the start of storage and within + 3 % to + 11 % on 27 November 2025. The OpenMC assembly-level model exhibits systematically lower values, with deviations ranging from approximately − 8 % to − 14 % at the start of storage and from − 2 % to − 7 % at the later reference time. These deviation ranges are therefore adopted as an estimate of the uncertainty of the decay heat input data, and the three fuel assembly models will be used to perform a sensitivity analysis of the heat transfer model and of the outlet air temperature.
Considering the principle commonly applied in the nuclear industry that “a conservative approach should be applied,” it is reasonable to assume that the residual heat values provided for fuel transfer purposes are overestimated. Taking this into account, the lower residual heat values obtained in the present calculations are likely to provide a more realistic representation of the actual thermal power.
It is important to emphasize that all calculations were performed using the specified irradiation cycle lengths and average burnup values. Since the residual heat results obtained from the three models do not fully coincide, all results derived from the standard correlation model as well as from both OpenMC-based models will be examined in the validation of the thermal model. However, in the remainder of the present publication, only the residual heat data provided by the standard correlation model are analyzed, owing to the significant differences in computational time between the investigated depletion and decay models.
In the case of the approximate method, the program calculated daily resolved data for 977 fuel assemblies over a 50-year period in 13.3 min. In contrast, the OpenMC software (internal version v0.3, November 2025 build) requires between 25 and 40 min to calculate decay heat data for a single fuel assembly at three time points. Extrapolated to all 977 fuel assemblies, this corresponds to approximately 24 days of continuous computation, which was still ongoing at the time of writing this article.
The data obtained from the standard correlation model were aggregated on a per-storage-chamber basis in order to assess whether the daily temporal resolution applied is sufficient for the validation of the heat transport model. By comparing the thermal state at the completion of loading into the SFISF with the thermal state on the last day of the investigated time interval—that is, considering a time span of five years and four months—for the fuel assemblies stored in chamber No. 21, the residual heat power decreased from 135,774 W to 92,169 W, corresponding to an approximate reduction of 43 kW. This decrease indicates that, on an annual time scale, a significant reduction in thermal power occurs during interim storage, primarily due to the decay of short- and medium-lived radioisotopes.
When considering a shorter time scale—namely, the entire November 2025 interval modeled in parallel with the measurement campaign—the reduction in thermal power in storage chamber No. 21 amounted to 249 W over this period, which corresponds to 0.27% of the total thermal power calculated for the beginning of November. Expressed on a daily basis, this represents an average decrease of 9.6 W in the total thermal power of the storage chamber, corresponding to 0.01% of the total thermal power at the beginning of November 2025. The accuracy of the temperature sensors lies between ±0.10 and ±0.15 °C, which, relative to the expected temperature measurement range of approximately 50 °C, corresponds to a deviation (measurement uncertainty or error) of ±0.20–0.30% with respect to the real value. This magnitude is therefore comparable to the percentage decrease in thermal power over the investigated month.
For these reasons, it can be stated that, for validation purposes, the daily resolved results obtained from the standard correlation model are of sufficient accuracy. Moreover, from the perspective of temporal resolution, even the single time-point data provided by the OpenMC calculations can be considered adequate.
Figure 3 below shows the thermal power distribution of SFISF storage chamber No. 21 at two different points in time. The thermal power distribution is non-uniform both along the flow direction and in the direction perpendicular to it. Based on this observation, it is expected that the results obtained from the heat transport model calculations will show that the temperature of the flowing air is not uniform along the horizontal axis perpendicular to the main flow direction. As the difference between the minimum and maximum fuel assembly thermal powers decreases over time—from a difference of Δ 278.62 W to Δ 122.12 W—the measured storage chamber temperature does not represent a purely local value. Instead, it corresponds to an average outlet air temperature taken along the horizontal axis perpendicular to the main flow direction, which is higher than the inlet air temperature. Determining whether the storage chamber temperature measurement represents a local value or an average over the entire outlet air cross-section—that is, deciding whether the previously installed instrumentation measures a local or an averaged quantity, which is an important aspect from an operational perspective—can only be accomplished after running the heat transport model.
Figure 3. Top-view thermal power map of storage chamber No. 21 of the SFISF, based on data obtained from the standard correlation model, at the end of the fuel loading period and on the last day of the control measurement interval. The colored circles represent the individual storage tubes, while the color intensity indicates the thermal power of the fuel assembly contained in each tube. The color corresponding to the thermal power is defined by the scale shown on the right-hand side of the figure. The arrow located at the center of the figure indicates the airflow direction, which allows the relative position of the fuel assemblies to be interpreted with respect to the flow path.
The axial residual heat power distribution of a fuel assembly is inherently non-uniform along its length. This axial inhomogeneity originates from two coupled physical effects. First, the uranium mass per unit length ( m U / Δ l ) decreases toward both axial ends of the fuel rod. Second, as a direct consequence of neutron leakage and scattering effects, the local neutron flux is reduced near the ends of the fuel rods during irradiation. This leads to a locally lower burnup of the terminal fuel pellets compared to the central region of the rod. As a result, the peripheral fuel pellets exhibit a different isotopic composition and decay heat contribution than those located in the middle section. In the present heat transport model, this axial inhomogeneity is explicitly taken into account by scaling the calculated decay heat distribution using experimentally derived axial flux profiles. This approach ensures that the non-uniform burnup and isotope production along the fuel rod are consistently reflected in the applied residual heat power model.
In the heat transport model, this axial inhomogeneity is represented by scaling the calculated total heat power using an axially varying distribution derived from measured axial neutron flux profiles. Based on a literature review [31,32,33,34,35], our axial distribution approximation was developed using the work of P. Kirchknopf and co-authors as a reference [36]. Their study presents several axial distributions of the 137Cs isotope for different fuel assemblies. By selecting the case with the lowest cesium inventory, a heat power distribution was derived and used as a proportionality function. In this approximation, it was assumed that other high-activity fission products exhibit a similar axial distribution within the fuel assembly.
The heat transport model applies this proportionality function to axially scale the simulated thermal heat sources, starting from the residual heat power determined for the fuel assembly as a whole.
For VVER-440 fuel assemblies manufactured by TVEL (Moscow, Russia), two main groups can be distinguished based on their mechanical design: working (operational) fuel assemblies and control fuel assemblies. According to the mechanical design documentation provided by the manufacturer, the active lengths of the fuel rods—i.e., the regions containing fuel pellets—differ between these two types. For standard fuel assemblies, the active length is 2420 mm, whereas for control fuel assemblies it is 2320 mm.
In Figure 4 below, the axial heat power distribution function of the standard fuel assembly (RK) is shown in purple, while that of the control fuel assembly (ARK) is shown in green, both plotted as a function of the axial position along the fuel assembly.
Figure 4. Approximate heat power distribution ratio curves of the working (RK, purple solid line) and control (ARK, green dashed line) fuel assemblies. The black circle indicates the assumed location of the compensation volume at the upper part of the fuel rods.
In the axial 137Cs distribution figure presented by P. Kirchknopf and co-authors, a short segment can be observed that is parallel to the x-axis. Over this segment, the gamma flux distribution appears excessively uniform. We therefore assume that this unusually uniform distribution may indicate the presence of easily mixing, likely gaseous isotopes generated within the fuel rod, and that this region is labeled as 137Cs solely due to measurement uncertainty. From a mechanical design perspective, this straight segment most likely corresponds to the gas compensation volume located above the active part of the fuel rod.
Based on this interpretation, and using the known active and total lengths of the fuel rods as well as the overall dimensions of the fuel assembly, we were able to define an approximate thermal power distribution curve along the full axial coordinate. Most of the gaseous radioisotopes produced during fission have half-lives on the order of a few hours to a few days, with the notable exception of 85Kr, which has a half-life of 10.7 years. It is therefore likely that this isotope was still present both at the time of loading into the SFISF and during the investigated storage period. Consequently, as a first approximation, the segment of the relative thermal power distribution curve corresponding to the gas compensation volume was retained.
Based on these results, it can be concluded that, for the axial residual thermal power distribution presented in Figure 4 and summarized in tabular form in Appendix C, the assumption of zero heat generation in those axial regions of the fuel assemblies containing only structural materials is physically justified and quantitatively validated.
The main data points of the graph shown in Figure 4 are summarized in Appendix C, thereby enabling the accurate and transparent reproduction of the proposed approximation in subsequent and independent studies. Quantitative results supporting this assumption, including the relative activity of structural components, are summarized in Appendix D.
In the case of the axial distribution curve presented in Figure 4, the function assumes non-zero values only along the axial segment containing the fuel pellets and within the gas plenum volume located above them. Along those axial regions of the fuel assembly where only structural materials are present, the residual heat power was approximated as zero. Both the negligibility of the structural materials and the assumed equivalence between the axial burnup distribution and the 137Cs distribution were first supported by literature data and subsequently confirmed by targeted verification calculations.
These verification calculations were also performed using the OpenMC code, focusing on the axial distribution of the residual thermal power and isotopic composition of a representative fuel assembly. Figure 5 presents three vertically stacked plots that clearly illustrate the individual verification steps and allow a clear distinction between the obtained results.
Figure 5. Results of the verification calculations for the axial heat power distribution of a fuel assembly. The upper plot shows the 137Cs axial distribution derived from the measurements of P. Kirchknopf et al. and the corresponding burnup-related axial function inferred from it. The middle plot presents the axial residual heat power distributions calculated by OpenMC for different time points. The bottom plot illustrates the correlation between the axial residual heat power distribution of a fuel assembly at the time of loading into the SFISF and the corresponding axial 137Csinventory distribution.
In the first step, an axial residual heat power function divided into 19 axial segments was derived based on the known 137Cs axial ratio function, while the contribution of the gas plenum volume was neglected. In the upper plot of Figure 5, the 137Cs ratio function derived from the data published by Kirchknopf et al. is shown in purple, while the corresponding stepwise axial heat power distribution derived from it is shown in green.
In the second step, a three-dimensional fuel assembly burnup calculation was performed using OpenMC. In this model, the same axial segmentation scheme—defined by the authors for the residual heat power function—was applied. For these axial zones, OpenMC emergently determined the local isotopic compositions, activities, and residual heat powers at three different time points based on the locally calculated neutron flux.
The fuel assembly model was constructed using known mechanical design data. The fuel rod cladding was defined as a Zr + 1 wt.% Nb alloy, while the assembly wrapper was modeled as Zr + 2.5 wt.% Nb. Except for the central rod, helium filling inside the rods and the presence of primary coolant water between the rods were taken into account. The surrounding medium of the fuel assembly was modeled as light water enclosed within an external reflective cylindrical boundary.
The results of the burnup and subsequent cooling calculations are shown in the middle plot of Figure 5. The residual heat power distribution immediately after reactor discharge is depicted in purple, where the dominant contributor to activity at this early time point is 239U, originating from short-lived activation products.
The residual heat power distribution calculated for the time of loading into the Spent Fuel Interim Storage Facility (SFISF) is shown in green in the middle plot of Figure 5. A very similar distribution was obtained for the time point corresponding to our validation measurements, which is shown in blue. According to the isotopic inventories calculated by OpenMC, in both the loading and measurement time points the dominant contributor to activity is 137Cs.
In the bottom plot of Figure 5, the axial residual heat power distribution at the time of loading into the SFISF (purple) is compared directly with the axial distribution of the 137Cs inventory calculated for the same time point. The zone-wise residual heat power distribution obtained from the OpenMC three-dimensional, transport-coupled burnup calculations for cooling times exceeding five years shows a strong agreement with the axial 137Cs distribution. This is consistent with the fact that, at such cooling times, a significant fraction of the decay heat is generated by long-lived fission products whose production is approximately proportional to the cumulative burnup. The remaining discrepancy can be handled using an industry-standard proportional scaling approach, whereby a constant C is defined to improve the numerical overlap between the 137Cs distribution and the residual heat power function.
Two axial distribution approximations will be applied during the model validation, and the uncertainty associated with these approximations will be treated as part of a sensitivity analysis. In the first approach, the axial residual heat power distribution for each fuel assembly is determined directly from the OpenMC model for a selected time instant within the validation measurement interval and is implemented into the SFISF model. In the second approach, the heat power distribution is derived from the 137Cs axial distribution measured by P. Kirchknopf and co-workers, using the proportionality constant C determined from the OpenMC calculations of the first approach.

3. Measurement Data

The measurement data were provided by three different systems. Two of these systems have been in long-term operation at the Spent Fuel Interim Storage Facility (SFISF) and are used for monitoring technological conditions. One additional system was temporarily installed by us. The locations of the sensors of the systems listed below within the flow domain are indicated in Figure 6.
Figure 6. Locations of the measurement systems and their instruments used during data acquisition within the SFISF. Combined cross-sectional view of the SFISF chambers (SMAS = Storage Pipe Monitoring and Data Acquisition System, CFEPR = Compact Flow and Environmental Parameter Recorder, CTRS = Chamber Temperature Registration System).

3.1. Storage Pipe Monitoring and Data Acquisition System

The first system presented is the Storage Pipe Monitoring and Data Acquisition System, abbreviated as SMAS. Its function is to measure the pressure in the storage pipes and to determine nitrogen leakage while taking environmental parameters, such as temperature and atmospheric pressure, into account. The system has a distributed intelligence system: one data acquisition unit is installed in each SFISF chamber group (chambers 1–11, 12–16, 17–20, 21–24, and 25–28), and these data acquisition units are queried by a central computer located in the operator room.
In addition to the pressure sensors of the storage pipes, each data acquisition unit is equipped with its own ambient temperature sensor and atmospheric pressure sensor. From the measured signals, minute- and hourly-averaged values are calculated, and based on the averaged and normalized values, leakage rates are computed for the individual pipe groups. From these systems, the signals of a total of five temperature sensors are used for the whole validation process of our heat transport model.
The SMAS associated with chambers 1–11, the ambient temperature measurement is performed directly at the air inlet point. The sensor is located at chamber 4 in a position protected from solar radiation. The sensor is an PT100 with accuracy class A1 (±0.15 °C interchangeability error [37]). It is assumed that the parameters of the incoming air—such as temperature, atmospheric pressure, and humidity—are identical for all chambers. Consequently, for the modeling of chambers 12 and 21, the minute-resolved data recorded by this sensor are used as model execution data. Among the 28 storage chambers, Chambers 12 and 21 were selected for this study because their residual heat powers differ significantly, as also confirmed by the calculations presented in Section 2. Since both the power of individual fuel assemblies and the total thermal power of each chamber vary slowly over time, the effect of power decay on the induced airflow can be taken into account in the subsequent model validation by analyzing two chambers that were loaded at different times. Furthermore, within their respective chamber groups, Chambers 12 and 21 were selected because the CTRS measurement probes are currently installed in these locations. Relocating the probes to other chambers would involve work under elevated radiation exposure conditions and is therefore considered a high-radiation-risk operation. From an engineering and radiation protection perspective, such relocation, together with the associated additional personal dose burden, is not technically justified.
In the case of the other chamber groups, the ambient temperature sensors are located on the loading deck, inside the service shaft. Their signals are used partly to set the initial air temperature of the enclosed space above the storage tubes—i.e., for model initialization—and partly at later stages for validation, by comparing calculated and measured local temperatures. The atmospheric pressure sensors of the local SMAS units are also located in the service shaft; based on their measurement range settings, their accuracy is ±0.28 mbar [38,39]. Expansion joints were implemented between the building modules and the internal structural units to allow relative movement of building parts in the event of an earthquake. Through these expansion joints, air can flow to a limited extent; therefore, the atmospheric pressure measured on the loading deck is equal to the external ambient atmospheric pressure. Within the set of model execution data, the ambient atmospheric pressure is applied using minute-resolved records.

3.2. Chamber Temperature Registration System

The second already existing measurement system is the Chamber Temperature Registration System, abbreviated as CTRS. This system consists of a portable data logging unit and a measurement probe. As shown in Figure 6, the 4.2 m long probe is located at the chamber outlet, in the center of the flow domain. The probe contains three PT100 temperature sensors of accuracy class A1 (±0.15 °C interchangeability error), positioned at intervals of 1.15 m along the probe. One such probe is available per module group, and these probes can be relocated between individual storage chambers. This measurement system is not operated continuously; it is typically used only during the loading of a given storage chamber to verify the expected temperature conditions.
The data logging unit calculates minute-averaged values; however, the output file is closed, i.e., it cannot be edited using third-party software, and the manufacturer’s freely available software allows only data visualization. Due to this limitation, hourly temperature values were read manually from the displayed graphs, and these extracted data were interpolated to minute resolution using the Piecewise Cubic Hermite Interpolating Polynomial (hereinafter: PCHIP) method [40]. Figure 7 shows the extracted and interpolated temperature data as a function of the exact measurement time for all six sensors. The numbering of the sensors follows the vertical orientation of the probe from bottom to top: sensor No. 1 is located at the lower end of the probe, sensor No. 2 above it, and sensor No. 3 at the top. The different temperature sensors and their corresponding temperature data are represented by different colors in Figure 7.
Figure 7. Evolution of the outlet air temperature of storage chambers 12 and 21 during November 2025. The different temperature sensors and their corresponding temperature data are represented by different colors.
Figure 7 summarizes the measurement results obtained in November 2025 and presents them in graphical form. Temperature values measured by the probes located in storage chamber 12 are plotted in purple, green, and light blue, while those measured in storage chamber 21 are shown in orange, lemon yellow, and dark blue. In the case of both chambers, the structure of the measurement probe is clearly reflected in the data; in other words, moving upward across the flow cross-section, the temperature increases according to the measurements. This result is consistent with the physical principle that air at higher temperature tends to rise above air at lower temperature.
In addition, Figure 7 also shows that the temperature increase in storage chamber 12 is lower than that observed in storage chamber 21, as indicated by the lower position of the curves. The reason for this difference is that storage chamber 12 contains fuel assemblies that have been cooling since 2003 and therefore exhibit lower residual heat power, whereas storage chamber 21 typically contains assemblies that were discharged only since 2013 (i.e., approximately ten years later), and thus have shorter cooling times. Following this, Figure 8 compares the temperatures measured at the outlet of storage chamber 21 with the temperature of the incoming air at the inlet. This comparison is clearly illustrated in Figure 8.
Figure 8. Air temperatures measured in the flow domain of storage chamber 21 at four characteristic positions. The temperature of the incoming air at the inlet, measured in °C, is indicated in red, while the other colors (orange, yellow, and light blue) represent the outlet air temperatures at the end of the storage chamber, measured by temperature sensors located at different heights within the flow domain.
Figure 8 shows that the temporal variation of the incoming air temperature, indicated by the purple curve, has a shape similar to that of the three curves characterizing the outlet air temperature. However, the magnitude of the integrating effect of the building and the thermal system itself on the flowing air cannot be precisely determined, since the outlet air temperature values shown in Figure 8 were interpolated to minute resolution from hourly measurement data using the PCHIP method. Nevertheless, the thermal inertia resulting from the building mass is clearly visible from the slower response to daily temperature fluctuations. In other words, during the early morning hours, the temperature difference between the inlet and outlet air is on average larger, whereas at daily peak temperatures this relative temperature difference is smaller.
The temperature values measured by the CTRS are intended to be used as validation data for our thermal model. However, based on the trends of the curves shown in Figure 8, it can be stated that these interpolated temperature values would be suitable for model evaluation only if the temporal resolution of the original data were of the same order of magnitude as the temporal resolution of the model execution parameters and the model time-stepping. In other words, for proper model validation, either the model performance must be examined on an hourly time scale, or the outlet air temperature must be provided at minute resolution. Otherwise, due to the integrating effect introduced into the temperature signal by the interpolation, the accuracy of the data obtained from the thermal model cannot be unambiguously assessed. Rather than quantifying the uncertainty introduced by the interpolation of validation data, the validation procedure is defined such that the model execution and the validation data are consistent in temporal resolution. Therefore, the validation simulations are carried out by selecting one of the two previous approaches.

3.3. Compact Flow and Environmental Parameter Recorder

The third measurement unit is an device developed by the authors and referred to as the Compact Flow and Environmental Parameter Recorder (CFEPR), the design of which has already been presented in a previous publication [41]. Two CFEPR units were manufactured and installed; these devices were placed at the air inlets of the storage chambers on the so-called wildlife protection grilles. Each unit contains six sensors that record temperature [42,43,44,45], atmospheric pressure [44], relative humidity [43,44], illuminance [46], and air flow velocity [42,47,48]. In total, the sensor set measures and locally records four temperature values, two relative humidity values, one atmospheric pressure value, two air flow velocity values, and one illuminance value.
Among the available measurements, the air flow velocity and relative humidity data are primarily relevant for the validation of the thermal model, while the remaining sensor data provide supplementary information on the local environmental conditions. It has already been established that the temperature values measured by the temperature sensors are strongly influenced by direct solar radiation. To compensate for the effects of solar irradiation, two approaches are currently under development by us. In the first approach, the model corrects the temperatures measured by the CFEPR based on a compensation function surface derived from the temperature sensor and illuminance sensor signals installed in storage chamber 4. In the second approach, the model calculates the thermal disturbance signal caused by irradiation of the temperature sensor’s surface using the signal of the illuminance sensor.
In the case of storage chamber 4, a temperature sensor is installed at a location fully protected from direct solar radiation and provides continuously reliable, accurate, and relevant data. This article and the validation of the thermal model does not aim at the validation or application of the compensation models, because the temperature data from the chamber 4’s sensor are free from solar irradiation effects and are therefore suitable for direct use in the validation process.
Our three-dimensional heat transport model includes the loading deck located above the storage chambers in order to assess, based on the model execution results, the extent to which the residual heat power of the spent fuel assemblies stored in the tubes affects the air temperature in the enclosed space above them. In addition to the ambient air temperature, the building is also influenced by direct solar radiation from the external environment. Accordingly, solar radiation is incorporated into the heat transport model as an irradiation source, for which the standardized ASTM G-173 dataset [49] is applied as the spectral irradiance function.
In the selected spectral dataset, the spectrum of direct solar radiation is provided for a plane perpendicular to the direction of the incident sunlight. Since the exact geographical coordinates and orientation of the SFISF are known, the angle of incidence of solar radiation and the corresponding total spectral irradiance can be determined. Furthermore, the timestamps of the measurements are available, which enables the incidence angle to be calculated on a minute-by-minute basis within the heat transport model.
The ASTM G-173 dataset defines the spectral irradiance under completely clear-sky conditions; however, cloudy and foggy periods were also observed during the parallel measurement campaign. One possible approach to account for meteorological conditions is to determine an approximate attenuation factor between 0 and 1 based on satellite images and to apply it as a scaling coefficient to the irradiance. However, the uncertainty associated with this empirical approach is difficult to quantify and therefore renders it unsuitable for model validation.
The CFEPR unit installed by us is equipped with a ROHM BH1750FVI ambient light sensor (ROHM Semiconductor, Kyoto, Japan) capable of measuring illuminance in the range of 0–65,535 lx. By utilizing this sensor, an effective irradiance value for the solar spectrum can be determined even during cloudy periods of the on-site SFISF measurements. The calculations presented in Appendix E are based on the work of Kokhanovsky [50] (2004), who investigated the optical properties of different cloud types.
In this study, two findings are particularly relevant for the present work. First, in the visible spectral range—corresponding to the 450–650 nm sensitivity range of our sensor—cloud absorption is negligible, while intensity losses originate primarily from reflection and scattering. Second, cloud absorption is approximately identical to that of liquid water; therefore, by applying the Beer–Lambert law, the irradiance transmitted through clouds can be determined beyond the visible spectral range.
Based on the optical behavior of clouds, the illuminance values measured and recorded by the CFEPR can be converted, using the procedure described in Appendix E, into the solar radiation intensity required for model execution. The uncertainty of this value arises mainly from the selection of the assumed effective cloud droplet size within its known realistic range.
The relatively large scale uncertainty of the BH1750 sensor originates from factory calibration tolerances and spectral mismatch. However, in the present study, the sensor is used primarily as a relative indicator of cloud attenuation. Absolute irradiance values are derived using the ASTM G-173 reference spectrum and site-specific solar geometry, which significantly reduces the impact of the intrinsic sensor gain uncertainty.
For the currently investigated period—November of the year 2025—the data of the second air flow sensor are unfortunately missing. The second air flow sensor, operating on a thermal dissipation principle, was retrofitted by soldering it onto a custom-made circuit board and subsequently installed in the data acquisition unit; however, this sensor did not withstand the more humid environmental conditions encountered during the autumn period. As a result, only a single (not redundant) air flow velocity measurement is available at both chambers, obtained using the Pitot-tube-based flow sensor. From the complete measurement campaign, the air flow measurement results of 27 November 2025 were selected and are presented in Figure 9.
Figure 9. Air flow velocities in storage chamber 21 measured in m/s during 27 November 2025. The flow velocities were normalized by applying a Bézier filter to the raw measured data.
Since the measuring instrument is located in a semi-open area, the measured air flow velocity values are significantly influenced by wind effects, which is also visible in Figure 9. The curve indicated in grey represents the raw measurement data as a function of the time of day. This curve clearly shows rapid, high-amplitude fluctuations in the flow velocity. In order to suppress the effect of wind, a Bézier filter with a window size of 21 and a tension parameter of 0.5 was applied. The resulting filtered flow velocity values are shown in Figure 9 as a blue curve.
The Bézier filter is applied to suppress the high-frequency components; i.e., wind effects and the associated local turbulent flow components. Due to the large size of the building, the presence of collimators within the flow channel, and the fact that the internal airflow is driven by temperature differences, the flow behavior is expected to be drived primarily by thermal effects. This temperature difference depends mainly on the ambient temperature, since the decrease in the heat power of the fuel assemblies is relevant on an annual time scale. Consequently, variations in the air flow velocity are expected to be slow, and their temporal evolution is anticipated to follow a time-dependent function of similar shape to that of the ambient air temperature. It should be emphasized that the present airflow measurements are not intended to characterize the entire flow field of the storage chamber. Instead, they are used exclusively for local, pointwise comparison at the measurement location, where the numerical model outputs are evaluated against the corresponding experimental data.
Figure 10 presents the results of the FFT analysis of the time-dependent inlet air velocity signal in its raw form and after Bézier filtering. In addition, the FFT spectrum of the inlet air temperature is shown for comparison in order to evaluate the effectiveness of the filtering procedure. For the raw airflow signal, indicated in purple, it can be observed—consistently with the temporal behavior shown in Figure 9—that the FFT spectrum contains significant components with both minute-scale and hour-scale periods. In the case of the signal processed using the Bézier filter, indicated in green, the amplitudes of the short-period (high-frequency) components are substantially reduced, whereas the magnitudes of the multi-hour components remain largely unchanged. For comparison, the FFT analysis of the inlet air temperature, shown in blue, indicates that its temporal variation is slow and that its spectrum is dominated by components with periods of several hours. Considering that the temperature variation of the fuel assemblies can be regarded as negligible over the investigated time interval, the temperature difference driving the airflow through the facility is primarily governed by the inlet air temperature. Since the variation in the ambient temperature is slow according to the measurement data, and only long-period components exhibit non-zero amplitudes in the FFT spectrum, it can be demonstrated that the Bézier-filtered airflow signal mainly removes high-frequency components that are not associated with temperature-driven natural convection. These rapidly varying components can therefore be interpreted as disturbances originating primarily from wind effects and other local turbulent flow phenomena.
Figure 10. Results of the FFT analysis of the airflow velocity–time signal processed using a Bézier filter. The raw airflow velocity is indicated in purple, the Bézier-filtered airflow signal is shown in green, and the FFT spectrum of the inlet air temperature is presented in blue.
It is assumed that the filtered measurement data obtained in this way are free from local disturbing effects and more realistically reflect the temporal variation of the actual air flow velocity. During the measurement campaign, the option of relocating the data logging device further downstream along the inlet flow path was considered; however, this option was ultimately discarded due to local radiation conditions. Based on the readout of our personal dosimeters, it was established that during equipment installation and inspection activities, work was performed in radiation fields with dose rates exceeding 600 μSvh. This elevated dose rate relative to background was not caused by radiation penetrating directly through the concrete structure, but rather by bremsstrahlung photons reflecting back and forth from the walls of the inlet duct.
If the device were relocated to a position along the air flow path that is better protected from direct solar radiation and direct wind exposure, the local dose rate would be expected to increase. For radiation fields of such magnitude, no available data exist regarding the radiation tolerance of the semiconductor-based sensors used in our data recorder. In other words, no manufacturer data are available on the level of ionizing irradiation these sensors can withstand prior to failure.
The types and accuracies of the applied sensors, grouped by measurement system, are summarized in Appendix F.

4. Summary

The presented procedure constitutes the compilation of a dataset required for empirical, prediction-based model validation, as the outputs of the numerical model will be compared, in a subsequent publication related to the present research, with experimental measurements that are independent of the model construction. For the sake of transparency, all elements of the applied datasets are summarized in Table 3 according to their mode of use.
Table 3. Overview of datasets according to their role in the modeling and validation process.
It is important to emphasize that the temperatures measured by the SMAS sensors in chambers No. 12 and No. 21 on the loading deck are used only once during the initialization of the heat transport model. Specifically, only the first value of the measurement time series is applied in order to establish realistic initial temperature conditions within the building. Although these temperature values are also designated for validation purposes, they are treated only as secondary Quantities of Interest (QoIs). Since the initial conditions of the heat transport model are fixed a priori, this dual use of selected dataset elements does not violate the principles of prediction-based validation.
By comparing the current CTRS temperature values with the inlet air temperature measured by the SMAS system in storage chamber No. 4, it was established that, in addition to measurement uncertainty, the interpolation process introduces an additional numerical error into the validation data. This error can, however, be eliminated either by increasing the sampling density of the existing measurements or by increasing the differentiation time step of the model. Given that the measurement uncertainties are known and the applied instrumentation is well characterized, it can be stated that their use is appropriate for the validation purposes described above.
With respect to the model execution parameters, three different models were applied to calculate the residual heat of the fuel assemblies, and differences were observed among their results. All three datasets will be introduced separately into the numerical model during individual model runs as estimated values. The results obtained from these three different decay/depletion models are treated as input quantities subject to uncertainty. Nevertheless, in each validation case the heat generation rate remains fixed and is not adjusted a posteriori to improve agreement with measurement results. By substituting the different thermal power estimates into the SFISF storage chamber model, the impact of uncertainty originating from the estimation of fuel residual heat power is interpreted as a sensitivity study. This approach allows assessment of the extent to which discrepancies between model predictions and measurements can be attributed to uncertainty in the fuel heat generation.
In Table 3, two additional elements are shown in parentheses that were not discussed in the preceding chapters. These elements do not form part of the core validation dataset but can be applied optionally. Wind speed and wind direction, listed as model execution data, can be incorporated into the model as disturbance inputs affecting the system. The technological limits listed as validation-related technological parameters can be applied for worst-case testing of the system after completion of the validation process, or as the validation’s final step.
In the present manuscript, the uncertainty of the decay heat input is quantified through a comparative analysis of the ANSI/ANS-5.1 correlation and two OpenMC-based approaches, as presented in Table 2. Based on this comparison, an effective input uncertainty range of approximately −14% to +11% is identified and explicitly discussed in the text. It is important to emphasize that the primary objective of the present work is the compilation, systematization, and documentation of a high-quality dataset for future prediction-based validation, rather than the execution of full-scale thermal model validation runs. Consequently, no complete heat transport simulations with propagated input uncertainties have yet been performed within the scope of this study. The quantified decay heat uncertainty range is therefore introduced as a key input uncertainty parameter for subsequent validation and sensitivity analyses. The propagation of this uncertainty to output quantities, such as air and tube temperatures, and the determination of differential sensitivity coefficients (e.g., Δ T / Δ Q ) are planned to be addressed in a follow-up publication, in which full thermal model simulations will be presented.
In this context, the present study establishes the necessary quantitative basis for such future sensitivity and validation analyses by providing a transparent and reproducible characterization of the dominant input uncertainties.

Author Contributions

Conceptualization, A.É.; methodology, A.É.; software, A.É.; validation, E.R.; formal analysis, A.É.; investigation, A.É.; resources, A.É.; data curation, A.É.; writing—original draft preparation, A.É.; writing—review and editing, E.R.; visualization, A.É.; supervision, E.R.; project administration, A.É. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The data presented are available on a limited basis. Access to the data may be obtained from the corresponding authors upon request.

Acknowledgments

The authors gratefully say thank you very much for the support of Obuda University, Doctoral School of Applied Informatics and Applied Mathematics. We also thank the staff of PURAM for enabling the placement of our measuring instruments at the SFISF, as well as for providing access to the related additional data.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

The following abbreviations are used in this manuscript:
FDMFinite Differences Method
SFISFSpent Fuel Interim Storage Facility
CHeTMoSComplex Heat Transfer Modeling Software
SMASStorage Pipe Monitoring and Data Acquisition System
CTRSChamber Temperature Registration System
CFEPRCompact Flow and Enviromental Parameter Recorder
PCHIPPiecewise Cubic Hermite Interpolating Polynomial
LWRLight Water Reactor
ANSIAmerican National Standards Institute
ANSAmerican National Standard
ISOInternational Organization for Standardization
QoIQuantity of Interest
NPPNuclear Power Plant
PURAMPublic Limited Company for Radioactive Waste Management
RKRabocha Kasetta (Working Assembly)
ARKAkteevbaya Rehgyooleerooyushya Kasetta (Control Assembly)

Appendix A

The present appendix summarizes the calculation sequence that was used to determine the temporal variation of the residual heat of spent nuclear fuel. It is based on the ISO 10645 (ANS 5.1) standard and contains only such refinements as were necessary in order to adapt it to the available data.
P T ( t , T ) = P F ( t , T ) + P C ( t , T ) + P E ( t , T ) + P A ( t , T ) + P S ( t , T )
P T ( t , T ) —total remanent heat of the spent fuel assembly
P F ( t , T ) —heat generated by fission products
P C ( t , T ) —heat generated by 134Cs produced by neutron capture
P E ( t , T ) —heat generated by other nuclides originating from neutron capture
P A ( t , T ) —heat generated by actinides
P S ( t , T ) —heat generated by activation of structural materials
P F ( t , T ) = m U · S avg ∑ i = 1 4 w i 1 Q i ∑ k = 1 n ∑ j = 1 23 α i j λ i j 1 − e − λ i j · T k · 86,400 e − λ i j · t k · 86,400
m U —total uranium mass of the fuel kgU
S avg —specific thermal operating power W kgU
w i —power fraction of nuclide i  1
Q i —fission energy of nuclide i  MeV
α i j —j-th coefficient of nuclide i  MeV s
λ i j —j-th decay constant of nuclide i  1 s
T k —fuel irradiation time during cycle k  day
t k —time elapsed since the end of fuel irradiation in cycle k  day
S avg = B tot T sum · 10 6
B tot —average burnout MW day / kgU
T sum —fuel irradiation time day
P C ( t , T ) = m U · Y · E · λ 4 · S avg Q 1 − e − ( λ 4 + σ 4 ϕ ) T sum · 86,400 λ 4 + σ 4 ϕ + e − σ 3 ϕ T − e − ( λ 4 + σ 4 ϕ ) T sum · 86,400 σ 3 ϕ − ( λ 4 + σ 4 ϕ ) e − λ 4 t · 86,400
t—time elapsed since the start of cooling day
Y—effective cumulative yield of 133Cs per fission 0.0638
λ 4 —decay constant of 134Cs 1.071 × 10 − 8 s − 1
σ 3 —spectrum-averaged ( n , γ ) cross section of 133Cs 11.3 × 10 − 24 cm 2
σ 4 —spectrum-averaged absorption cross section of 134Cs 11.3 × 10 − 24 cm 2
E—recoverable energy per decay of 134Cs 1.721 MeV
ϕ —average neutron flux n cm 2 s
Q = ∑ i = 1 4 w i Q i
ϕ = S avg E s 2 + 1 · 2.58 · 10 10
E s —initial fuel enrichment
P E ( t , T ) = H ( t ) · P F ( t , T )
H ( t ) —time-dependent correction factor for other neutron capture nuclides, derived from the tabulated values of ANSI/ANS-5.1 as a function of cooling time.
P A ( t , T ) = m U · 1.82 · S avg − 0.06 ∑ n = 1 7 β ^ n e − λ n t
β ^ 1 = β 1 − β 2 E 1 E 2 λ 1 λ 1 − λ 2
β ^ 2 = β 2 1 + E 1 E 2 λ 1 λ 1 − λ 2
β ^ n = β n , n = 3 , … , 7
β n —actinide coefficient W kgU
E 1 —thermal energy per decay of 241Am 5.629 MeV
E 2 —thermal energy per decay of 241Pu 5.361 × 10 − 3 MeV
P S ( t , T ) = A ( t ) · P F ( t , T )
A ( t ) —time-dependent correction factor for the activation of structural materials, derived from the tabulated values of ANSI/ANS-5.1 as a function of cooling time.

Appendix B

Below, the manufacturer’s data of TVEL-fabricated fuels used at the Paks Nuclear Power Plant are summarized, which are relevant for the calculation of residual power.
Table A1. Fuel parameters.

Appendix C

The present appendix contains, in tabulated form, the data points of the power ratio curve prepared by us on the basis of the measurements of P. Kirchknopf et al. and used in our heat transport model, for both the working fuel assembly and the control fuel assembly.
Table A2. Table of heat power factor coordinates for work (RK) and control (ARK) fuel assemblies.

Appendix D

This appendix summarizes the results of the verification calculations performed to quantify the activity contribution of structural components relative to the fuel pellets. The calculations were carried out using the OpenMC code for five representative fuel assemblies. Activities were evaluated at the start of storage and at the target evaluation date (27 November 2025), corresponding to the validation measurement campaign.
Table A3. Calculated activities of fuel pellets and structural components for representative fuel assemblies at the start of storage and at the target evaluation date (27 November 2025).
The results demonstrate that the activity contribution of structural components remains below 0.3% at the start of storage and decreases to the order of 10 − 3 % by the target date. Consequently, the assumption of negligible heat generation in structural-only axial regions of the fuel assemblies is quantitatively justified.

Appendix E

This appendix summarizes the approximate calculation used in the heat transport model to estimate the spectral irradiance incident on the building under cloudy conditions in the wavelength range from 300 to 2500 nm. The derivation is based on the work of Kokhanovsky, who demonstrated, among others, that the spectral absorption behavior of clouds is approximately identical to that of liquid water. In the visible spectral range, cloud absorption is close to zero, while radiative losses primarily originate from reflection and scattering processes.
Within the CFEPR system, a lux sensor sensitive in the wavelength range of 450–650 nm is available, for which both the spectral sensitivity function and the angular response characteristic are known. The fundamental principle of the method is that, instead of directly determining the cloud liquid water thickness from the lux measurements, an effective optical thickness is derived in the visible range and subsequently extended to the full solar spectrum based on the physical properties of clouds.
L clear = 683 ∫ E e , λ ( λ ) V ( λ ) d λ
where
L clear —illuminance under clear-sky conditions [lux]
E e , λ ( λ ) —spectral irradiance from ASTM G-173 AM1.5 spectrum [W·m]
V ( λ ) —sensor’s photopic spectral sensitivity function [–]
683—photometric conversion factor [lm·W]
λ —wavelength [nm]
R = L meas L clear
where
R—dimensionless illuminance ratio [–]
L meas —measured illuminance [lux]
L clear —calculated clear-sky illuminance [lux]
This ratio represents the cloud extinction in the visible spectral range. Based on this quantity, an effective optical thickness can be defined, characterizing the scattering-dominated cloud effects between 450 and 650 nm.
τ vis = − ln ( R )
where
τ vis —effective extinction optical thickness in the visible range [–]
The cloud liquid water path (LWP) can be estimated using a standard cloud microphysical approximation as:
LWP ≈ 2 3 ρ w r eff τ vis
where
LWP —liquid water path [ kg · m − 2 ]
ρ w —density of liquid water (≈ 1000 kg · m − 3 )
r eff —effective cloud droplet radius [m]
τ vis —visible optical thickness [–]
κ w ( λ ) = α w ( λ ) ρ w
where
κ w ( λ ) —mass-specific absorption coefficient [ m 2 · kg − 1 ]
α w ( λ ) —volumetric absorption coefficient [ m − 1 ]
ρ w —water density [ kg · m − 3 ]
τ abs ( λ ) = κ w ( λ ) LWP
where
τ abs ( λ ) —absorption optical thickness at wavelength λ [ − ]
E e , λ eff ( λ ) = E e , λ ( λ ) C e − τ abs ( λ ) μ 0
where
E e , λ eff ( λ ) —effective spectral irradiance reaching the ground below clouds [ W · m − 2 · nm − 1 ]
C—“gray cloud” factor, approximately C ≈ R [ − ]
τ abs ( λ ) —spectral absorption optical thickness [ − ]
μ 0 = cos θ ⊙ —cosine of the solar zenith angle [ − ]
μ 0 = cos θ ⊙
where
θ ⊙ —solar zenith angle [ rad or ° ]
E e cloud = ∫ 300 2500 E e , λ eff ( λ ) d λ
where
E e cloud —effective total irradiance reaching the ground under cloudy conditions [ W · m − 2 ]
The calculations can be performed in advance for the entire investigated time interval using the CFEPR measurement data, and the results can be summarized in a minute-resolution database. During model execution, the program substitutes the corresponding instantaneous irradiance values into the heat transport model to represent the effect of direct solar radiation.
The primary source of uncertainty of this approximation originates from the uncertainty of the effective droplet radius r eff , which can be quantified through a parametric sensitivity analysis performed over a realistic parameter range.

Appendix F

This appendix summarizes, by measurement system, the types and accuracies of the instruments used in compiling the model validation dataset.
Table A4. Summary of measurement uncertainties of the sensors used in the validation dataset.

References

  1. Oberkampf, W.L.; Roy, C.J. Verification and Validation in Scientific Computing; Cambridge University Press: Cambridge, UK, 2010; Chapter 2; pp. 32–35. Available online: https://www.researchgate.net/publication/237076931_Verification_and_Validation_in_Scientific_Computing (accessed on 6 February 2026).
  2. Murray-Smith, R. Testing and Validation of Computer Simulation Models; Springer: London, UK, 2015; Chapter 2; pp. 19–31. [Google Scholar]
  3. American Society of Mechanical Engineers (ASME). Guide for Verification and Validation in Computational Solid Mechanics; ASME V&V 10-2006; ASME: New York, NY, USA, 2006. [Google Scholar]
  4. Oberkampf, W.L.; Trucano, T.G. Verification and Validation in Computational Fluid Dynamics. Prog. Aerosp. Sci. 2002, 38, 209–272. [Google Scholar] [CrossRef] [Scilit]
  5. Roache, P.J. Verification and Validation in Computational Science and Engineering; Hermosa Publishers: Albuquerque, NM, USA, 1998; Available online: https://scispace.com/pdf/verification-and-validation-in-computational-science-and-52t7f4iqq8.pdf (accessed on 6 February 2026).
  6. Érchegyi, A.; Rácz, E. Heat Conduction Model Based on the Explicit Euler Method for Non-Stationary Cases. Entropy 2025, 27, 994. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. American Society of Mechanical Engineers (ASME). Standard for Verification and Validation in Computational Fluid Dynamics and Heat Transfer; ASME V&V 20-2009; ASME: New York, NY, USA, 2009. [Google Scholar]
  8. Trucano, T.G.; Swiler, L.P.; Igusa, T.; Oberkampf, W.L.; Pilch, M. Calibration, Validation, and Sensitivity Analysis: What’s What. Reliab. Eng. Syst. Saf. 2006, 91, 1331–1357. [Google Scholar] [CrossRef] [Scilit]
  9. Hungarian Atomic Energy Authority (HAEA). First National Report under the Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management; Hungarian Atomic Energy Authority (HAEA): Budapest, Hungary. Available online: https://www.oah.hu/web/v3/HAEAportal.nsf/web?OpenAgent&menu=05&submenu=5_2 (accessed on 14 January 2026).
  10. International Atomic Energy Agency (IAEA). Guidebook on Spent Fuel Storage Options and Systems; IAEA: Vienna, Austria, 2024; Available online: https://www-pub.iaea.org/MTCD/Publications/PDF/DOC_010_240_web.pdf (accessed on 6 February 2026).
  11. International Atomic Energy Agency (IAEA). Survey of Wet and Dry Spent Fuel Storage; IAEA-TECDOC-1100; IAEA: Vienna, Austria, 1999; Available online: https://www-pub.iaea.org/mtcd/publications/pdf/te_1100_prn.pdf (accessed on 6 February 2026).
  12. American Nuclear Society. ANSI/ANS-5.1-2014, Decay Heat Power in Light Water Reactors; American Nuclear Society: La Grange Park, IL, USA, 2014; Available online: https://www.ans.org/store/item-700169/ (accessed on 14 January 2026).
  13. U.S. Nuclear Regulatory Commission (NRC). Decay Heat Power in Light Water Reactors: Regulatory Guide 1.157, Rev. 2; U.S. NRC: Washington, DC, USA, 2019. Available online: https://www.nrc.gov/docs/ML1613/ML16139A215.pdf (accessed on 4 February 2026).
  14. Rearden, B.T.; Jessee, M.A. (Eds.) SCALE Code System; Report ORNL/TM-2005/39; SCALE 6.2.3; Oak Ridge National Laboratory: Oak Ridge, TN, USA, 2018. Available online: https://info.ornl.gov/sites/publications/Files/Pub107333.pdf (accessed on 8 February 2026).
  15. Wieselquist, W.A.; Lefebvre, R.A.; Jessee, M.A. (Eds.) SCALE Code System; Report ORNL/TM-2005/39; SCALE 6.2.4; Oak Ridge National Laboratory: Oak Ridge, TN, USA, 2020. Available online: https://info.ornl.gov/sites/publications/Files/Pub186165.pdf (accessed on 8 February 2026).
  16. Leppänen, J. Serpent—A Continuous-Energy Monte Carlo Reactor Physics Burnup Calculation Code, User’s Manual; VTT Technical Research Centre of Finland: Espoo, Finland, 2015; Available online: https://serpent.vtt.fi/download/Serpent_manual.pdf (accessed on 14 January 2026).
  17. Romano, P.K.; Forget, B. The OpenMC Monte Carlo Particle Transport Code. Ann. Nucl. Energy 2013, 51, 274–281. [Google Scholar] [CrossRef] [Scilit]
  18. U.S. Nuclear Regulatory Commission. Final Safety Evaluation for Studsvik Scandpower Inc. CASMO5 Code System; U.S. NRC: Washington, DC, USA, 2017.
  19. Studsvik. CASMO5—Software Product Description/Flysheet (Vendor Documentation); Studsvik: Nyköping, Sweden, 2023. [Google Scholar]
  20. Studsvik. HELIOS-2 Nuclear Fuel Analysis Software—Flysheet (Vendor Documentation); Studsvik: Nyköping, Sweden, 2023. [Google Scholar]
  21. Marleau, G.; Hébert, A.; Roy, R. A User Guide for DRAGON, Version 5; Technical Report; Polytechnique Montréal: Montréal, QC, Canada, 2018. [Google Scholar]
  22. Studsvik. SIMULATE5—Software Product Description (Vendor Documentation); Studsvik: Nyköping, Sweden, 2024; web publication; Available online: https://www.studsvik.com/wp-content/uploads/2024/08/SIMULATE5_Flysheet_2024_V0-Final.pdf (accessed on 8 February 2026).
  23. Bahadir, T. Fixed-Source and Ex-Core Detector Calculations with SIMULATE5. In Proceedings of the MC2017 International Conference, Jeju, Korea, 16–20 April 2017; Available online: https://www.kns.org/files/int_paper/paper/MC2017_2017_6/P311S06-11BahadirT.pdf (accessed on 8 February 2026).
  24. Sublet, J.-C.; Eastwood, J.W.; Morgan, J.G.; Gilbert, M.R.; Fleming, M.; Arter, W. FISPACT-II: An Advanced Simulation System for Activation, Transmutation and Material Modelling. Nucl. Data Sheets 2017, 139, 77–137. [Google Scholar] [CrossRef] [Scilit]
  25. Sublet, J.-C. FISPACT-II User Manual; Report UKAEA-R(11)11 (Issue 8); United Kingdom Atomic Energy Authority: Culham, UK, 2016. [Google Scholar]
  26. Rizzo, A.; Vaglio-Gaudard, C.; Noguère, G.; Martin, J.-F.; Vallet, V.; Eschbach, R. Nuclear Data Adjustment Based on the Interpretation of Post-Irradiation Experiments: Application to the DARWIN2.3 Package. Epj Nucl. Sci. Technol. 2018, 4, 27. [Google Scholar] [CrossRef] [Scilit]
  27. San-Felice, L.; Eschbach, R.; Bourdot, P. Experimental Validation of the DARWIN2.3 Package for Fuel Cycle Applications. Nucl. Technol. 2013, 184, 217–232. [Google Scholar] [CrossRef] [Scilit]
  28. OECD Nuclear Energy Agency (NEA) Data Bank. ACAB-2008, ACtivation ABacus Code (NEA-1839); Code Abstract; OECD/NEA: Paris, France, 2011. Available online: https://www.oecd-nea.org/tools/abstract/detail/nea-1839/ (accessed on 2 January 2026).
  29. Umweltbundesamt Österreich. Hungary’s National Programme for the Treatment of Spent Fuels and Radioactive Waste—Strategic Environmental Assessment; Umweltbundesamt: Vienna, Austria, 2015; Available online: https://www.umweltbundesamt.at/fileadmin/site/themen/energie/kernenergie/verfahren/ungarn/entsorgungsprogramm/hunational_programme_rad_waste_de.pdf (accessed on 2 January 2026).
  30. Nguyen, C.T.; Almási, I.; Hlavathy, Z.; Zsigrai, J.; Lakosi, L.; Nagy, P.; Parkó, T.; Pós, I. Monitoring Burn-Up of Spent Fuel Assemblies by Gamma Spectrometry. IEEE Trans. Nucl. Sci. 2013, 60, 1107–1110. [Google Scholar] [CrossRef] [Scilit]
  31. Hegyi, G.; Keresztúri, A.; Maráczy, C. Calculation Method for 2nd Generation Fuel of VVER-440 and Some Application. In Proceedings of the International Conference Nuclear Energy for New Europe (NENE 2008), Portorož, Slovenia, 8–11 September 2008; Paper 206. pp. 206.1–206.8. [Google Scholar]
  32. Závorka, J.; Lovecký, M.; Škoda, R. Basic Design of the TEPLATOR Core—Construction. In 29th International Conference Nuclear Energy for New Europe (NENE 2020); Nuclear Society of Slovenia: Ljubljana, Slovenia, 2020; pp. 402.1–402.7. [Google Scholar]
  33. Brady-Raap, M.C.; Nomura, Y.; Sartori, E. Overview of the Burnup Credit Activities of the OECD/NEA. RAMTRANS 2001, 12, 213–224. [Google Scholar]
  34. Grahn, P.; Morén, L.; Wiborgh, M. Spent Nuclear Fuel for Disposal in the KBS-3 Repository; SKB Technical Report, no. TR-10-13; Svensk Kärnbränslehantering AB (SKB): Stockholm, Sweden, 2010; Available online: https://www.skb.com/publication/2151488/TR-10-13.pdf (accessed on 14 January 2026).
  35. Šnírer, M.; Krištofová, K.; Farkas, G.; Hausner, P.; Slugeň, V.; Borák, J. Advanced Approach to the Induced Activity Determination of VVER-440 Structural Components. Nucl. Eng. Des. 2022, 386, 111571. [Google Scholar] [CrossRef] [Scilit]
  36. Kirchknopf, P.; Almási, I.; Radócz, G.; Nemes, I.; Völgyesi, P.; Szalóki, I. Determining Burnup, Cooling Time and Operational History of VVER-440 Spent Fuel Assemblies Based on In-Situ Gamma Spectrometry at Paks Nuclear Power Plant. Ann. Nucl. Energy 2022, 170, 108975. [Google Scholar] [CrossRef] [Scilit]
  37. Emerson. Product Data Sheet: Rosemount 65 DIN-Style Temperature Sensors and Thermowells (Metric); Emerson Automation Solutions, Document No. 00813-0200-2654, Rev. MC. Emerson: Singapre, 2025. Table 1. p. 32. Available online: https://www.emerson.com/documents/automation/product-data-sheet-rosemount-din-style-temperature-sensors-thermowells-metric-en-73416.pdf (accessed on 8 February 2026).
  38. Emerson. Product Data Sheet: Rosemount 3051 Pressure Transmitter; Emerson Automation Solutions, Document No. 00813-0100-4001, Rev. WG; Emerson: Singapre, 2025; pp. 75–80. Available online: https://www.emerson.com/documents/automation/product-data-sheet-rosemount-3051-pressure-transmitter-en-73134.pdf (accessed on 8 February 2026).
  39. Emerson. Manual: Rosemount 3051 Pressure Transmitter (4–20 mA HART® Protocol); Emerson Automation Solutions, Document No. 00809-0100-4007, Rev. BG; Emerson: Singapre, 2024; p. 86. Available online: https://www.emerson.com/documents/automation/manual-rosemount-3051-pressure-transmitter-en-89452.pdf (accessed on 8 February 2026).
  40. Fritsch, F.N.; Carlson, R.E. Monotone Piecewise Cubic Interpolation. SIAM J. Numer. Anal. 1980, 17, 238–246. [Google Scholar] [CrossRef] [Scilit]
  41. Érchegyi, A.; Rácz, E. Recording Environmental Parameters for the Validation of the Thermal Model of the Spent Fuel Interim Storage Facility in Paks. In Proceedings of the 2025 IEEE 25th International Symposium on Computational Intelligence and Informatics (CINTI), Budapest, Hungary, 18–20 November 2025; IEEE Hungary Section; IEEE: New York, NY, USA, 2025; pp. 601–606. [Google Scholar]
  42. Sensirion AG. SDP3x-Digital: Digital Differential Pressure Sensor Datasheet. Technical Data Sheet (PDF), rev. 1.1, Nov. 2022. Available online: https://sensirion.com/media/documents/4D045D69/6375F34F/DP_DS_SDP3x_digital_D1.pdf (accessed on 6 February 2026).
  43. Sensirion AG. Datasheet SHT85: Humidity and Temperature Sensor. Datasheet (PDF), Version 4, Dec. 2021. Available online: https://sensirion.com/media/documents/4B40CEF3/640B2346/Sensirion_Humidity_Sensors_SHT85_Datasheet.pdf (accessed on 6 February 2026).
  44. Bosch Sensortec GmbH. BME280: Combined Humidity, Pressure and Temperature Sensor Datasheet. Document No. BST-BME280-DS001-23, rev. 1.23, Jan. 2022. Available online: https://www.bosch-sensortec.com/media/boschsensortec/downloads/datasheets/bst-bme280-ds002.pdf (accessed on 11 January 2026).
  45. Analog Devices Inc. LM75: Digital Temperature Sensor and Thermal Watchdog with Two-Wire Interface. Technical Data Sheet (PDF), rev. 3. Available online: https://www.analog.com/media/en/technical-documentation/data-sheets/lm75.pdf (accessed on 11 January 2026).
  46. ROHM Semiconductor. BH1750FVI: Digital 16-bit Serial Output Ambient Light Sensor IC. Technical Data Sheet (PDF), rev. D, Nov. 2011. Available online: https://www.mouser.com/datasheet/2/348/bh1750fvi-e-186247.pdf (accessed on 11 January 2026).
  47. Sensirion AG. Flow Element—SEK-SDP31 Evaluation Kit for SDP3x Differential Pressure Sensors. Application Note (PDF), ver. 0.2, Nov. 2022. Available online: https://sensirion.com/media/documents/62B8253D/63874BED/Sensirion_Differential_Pressure_Application_Note_SEK-SDP31_Flow_Elem.pdf (accessed on 6 February 2026).
  48. Renesas Electronics. FS3000 Datasheet. Technical Data Sheet (PDF). Available online: https://www.renesas.com/en/document/dst/fs3000-datasheet (accessed on 11 January 2026).
  49. National Renewable Energy Laboratory (NREL). Reference Air Mass 1.5 Spectra (ASTM G-173); NREL: Golden, CO, USA, 2012. Available online: https://www.nrel.gov/grid/solar-resource/spectra-am1.5 (accessed on 4 February 2026).
  50. Kokhanovsky, A.A. Optical Properties of Terrestrial Clouds. Earth-Sci. Rev. 2004, 64, 189–241. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.