Skip to Content
EnergiesEnergies
  • Article
  • Open Access

24 November 2026

23 Pages

Mapping Relative Urban Thermal Intensity with Thermal Remote Sensing: A Thermal Intensity Index Approach for Sustainable Urban Planning

,
and
1
Department of Urbanism, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain
2
Department of Advanced Urbanism, Faculty of Architecture, Gdansk University of Technology, Gabriela Narutowicza 11/12, 80-233 Gdansk, Poland
*
Author to whom correspondence should be addressed.
Energies2026, 19(23), 5687;https://doi.org/10.3390/en19235687 
(registering DOI)
This article belongs to the Special Issue Smart Cities and Energy Efficiency: Spatiotemporal Big Data Analytics for Sustainable Urban Development

Abstract

Improving energy efficiency is a significant challenge for sustainable urban development, and thermal remote sensing offers opportunities to examine urban thermal characteristics. However, studies relating spatial patterns of relative thermal intensity to urban, socio-economic, and environmental characteristics remain limited. Using Gdynia (Poland) as a case study, this research examines what a relative thermal index derived from a colour-mapped 3D thermographic model provided by OPEC can reveal about spatial thermal patterns across its 21 districts and how they relate to urban structure. The model is based on night-time aerial thermal imagery acquired over three nights in March 2021. A relative Thermal Intensity Index (TII, 0–100), derived from ordinal colour-palette positions rather than calibrated temperatures or direct measurements of heat loss, was developed at the tile level (approximately 300 m). The TII was related to urban structural, socio-economic, and environmental characteristics using Spearman correlations, Moran’s I, and Local Indicators of Spatial Association (LISA). At the district level, the relative TII was most strongly associated with building footprint coverage (ρ = 0.74) and negatively associated with forest cover (ρ = −0.54). Strong spatial autocorrelation was observed (Moran’s I = 0.673), with higher relative TII values in Śródmieście and Kamienna Góra. The main patterns were stable across processing choices but depended on spatial scale. The findings demonstrate the potential of existing 3D thermographic products for exploratory urban thermal screening while highlighting the need for independent, calibrated measurements before drawing conclusions about building-level energy performance or selecting retrofit measures.

1. Introduction and Background

Urban areas account for a significant proportion of global energy consumption and greenhouse gas emissions, making energy efficiency improvements a key objective of sustainable urban development [1,2]. The spatial organization of cities, including building density, land-use patterns, transport infrastructure, and green spaces [3], significantly influences urban thermal behavior, thereby impacting energy demand, environmental quality, and climate change resilience [4,5,6]. Therefore, understanding how thermal characteristics vary across urban environments is increasingly recognized as a fundamental element of evidence-based urban planning. Rather than simply indicators of building performance, spatial thermal patterns provide valuable information about the interaction between urban form and environmental conditions, supporting the design of more energy-efficient and climate-responsive urban structures [7].
The need for such planning approaches is particularly important in Poland, where the existing building sector faces significant energy efficiency challenges. The country has over 15.2 million buildings, covering a usable land area of approximately 2.53 billion square meters, most of which were constructed before 1990 according to standards that did not prioritize thermal efficiency [8]. It is estimated that roughly 6.5 to 7.5 million buildings require thermal modernization, including improvements to insulation and heating systems, to reduce energy consumption and greenhouse gas emissions [9]. These challenges are especially pronounced in urban areas, where dense urban sprawl, aging infrastructure, and diverse land-use patterns result in significant spatial variations in energy demand and thermal conditions.
The implementation of the revised Energy Performance of Buildings Directive (EPBD) further emphasizes the need for effective strategies supporting urban energy transformation [10]. The Directive requires Member States to accelerate building renovation, improve energy performance, and progressively achieve zero-emission buildings, while the Polish National Building Renovation Plan (Krajowy Plan Renowacji Budynków, KPRB) estimates that approximately 200,000 single-family houses, 13,000 multi-family buildings, and 16,000 public buildings should undergo thermal renovation annually to meet national objectives. Achieving these targets requires investments estimated at approximately PLN 550 billion by 2035 [9]. However, implementation is constrained by the scale of the building stock, financial limitations, conservation requirements in historic areas, and the practical difficulty of conducting detailed energy assessments across entire cities. Consequently, urban planners require spatial decision-support approaches capable of identifying priority areas where more detailed investigations and future interventions may be most beneficial.
Thermal remote sensing has become an important tool for analyzing the thermal properties of urban environments [11,12], enabling the monitoring of spatial variations in Earth’s surface temperature over large areas [13,14]. Airborne thermal images, in particular, provide suitable spatial resolution for studying differences between urban areas and neighborhoods, offering information that complements traditional urban and environmental datasets [15]. Numerous studies have used thermal remote sensing to investigate urban heat islands, Earth’s surface temperature dynamics, and the impact of urban form on thermal conditions [6,13,16]. More recently, thermal datasets have also been explored as supporting information for urban energy planning by identifying areas exhibiting distinctive thermal characteristics that may warrant further investigation [17,18].
Previous work falls into three strands, each with a different limitation for the present purpose. Satellite land-surface temperature, retrieved from calibrated radiances with emissivity and atmospheric corrections, offers city-wide coverage and a mature methodology, but at resolutions of tens of metres to about one kilometre it describes surface urban heat islands rather than neighbourhood contrasts or building energy [14,16]. Calibrated airborne thermography resolves individual roofs and can support city-scale building energy modelling [15], but depends on radiometric data and building-level inputs. Recent thermal-based mapping and retrofit-prioritisation studies combine thermal data with building or population information, but use calibrated or purpose-built datasets. Good practice across these strands includes radiometric calibration, emissivity correction, documented acquisition conditions, pixel-level georeferencing and validation against measured data [13,14,15,19].
However, thermal information alone provides only a partial understanding of energy-related processes in cities. Its interpretation becomes more meaningful when analyzed alongside urban environmental characteristics, including building density, population distribution, land cover, vegetation, and spatial configuration [19]. Such integrated analyses enable planners to better understand how urban structure influences thermal behavior and how these relationships can support the development of more energy-efficient urban environments. A further gap concerns municipal thermographic products such as the one available for Gdynia, which are delivered as colour-mapped visualisations (a textured 3D city model) without radiometric values, calibration or flight records. Such products are mainly used for visual inspection, and it is unclear what quantitative information they can support, at which spatial scale, and how sensitive any derived measure is to processing choices. A few studies examine how such a product can be used for spatial analysis. It meets few of the good-practice conditions above (Section 2.2), so the question is not how to follow best practice but what can responsibly be extracted from a product that falls short of it, and with which safeguards: an ordinal index, tile-scale analysis, sensitivity tests and exploratory treatment of all associations. In Gdynia specifically, no comprehensive neighborhood-level assessment has been conducted to examine how heat intensity varies across city neighborhoods and how these variations relate to urban environmental characteristics. This knowledge gap limits the application of thermal information as a planning tool for identifying areas that warrant closer investigation of possible heat loss and prioritizing future energy efficiency interventions.
Gdynia provides an appropriate case study for addressing this gap because its urban structure is characterized by considerable diversity, ranging from densely developed central districts to suburban residential areas and extensive forest complexes. This heterogeneity creates substantial spatial variability in built-up density, population distribution, land cover, and environmental conditions, offering an opportunity to investigate how these characteristics relate to thermal intensity patterns across the city.
This study aims to explore the thermal characteristics of 21 areas in Gdynia and examine their relationships with selected urban, social, economic, engineering, and environmental characteristics. Using aerial thermal images acquired during the 2021 heating season, a Thermal Intensity Index (TII) was developed to characterize the thermal properties of the urban environment and enable comparisons between areas. Statistical correlation analyses and spatial statistics, including Moran’s I and Local Indicators of Spatial Association (LISA), were then applied to examine spatial relationships and clustering patterns. The study addresses one main question: To what extent can a relative thermal index reconstructed from a colour-mapped municipal 3D thermographic product provide robust, scale-aware information on spatial thermal patterns and their association with urban structure in Gdynia, and what can it not support? Three sub-questions structure the analysis: (RQ1) How sensitive is the index to processing and aggregation choices? (RQ2) Does it show coherent spatial structure at tile level, and does this persist after controlling for building morphology? (RQ3) Which district-level indicators are associated with it, and how stable are these associations?
The study makes three contributions. It presents a reproducible procedure for reconstructing a relative index from the colour scale of a municipal product and tests its sensitivity (RQ1); it shows that the index has strong spatial structure that persists after controlling for building morphology, and that its associations with urban structure depend on scale (RQ2-RQ3); and it states what such an index cannot support: unlike land-surface temperature it is not a physical temperature, and unlike calibrated airborne thermography it cannot be attributed to individual buildings.

2. Materials and Methods

The methodological framework was designed to investigate the spatial distribution of thermal intensity across Gdynia and to examine its relationships with selected urban, socio-economic, geometric characteristics at the district level. The workflow consisted of two sequential phases: (1) the development of a Thermal Intensity Index (TII) based on aerial thermal imagery, and (2) the spatial and statistical analysis of the relationships between thermal intensity and district characteristics (Figure 1). The content of the Figure 1 was prepared by the authors, while the graphical form was developed with the assistance of ChatGPT-6.
Figure 1. The methodology scheme.
The analysis covered all 21 administrative districts of Gdynia. Thermal data were obtained from the municipal heating company OPEC and were derived from aerial thermal imagery collected during three nighttime flights conducted in March 2021 under comparable meteorological conditions. Nighttime acquisition was selected to minimize the influence of solar radiation and to better capture heat emitted from buildings and urban surfaces. The imagery was delivered as a textured three-dimensional city model partitioned into tiles of approximately 300 × 300 m, which served as the basic spatial unit.
In the first phase, a Thermal Intensity Index (TII) was developed to provide a standardized measure of the thermal characteristics of the built environment. The index was normalized to a scale ranging from 0 to 100, where higher values denote a warmer position on the color ramp of the rendering. Calculating the index at the tile level enabled spatially consistent comparisons within and between districts despite differences in their size, morphology, and land-use composition. District-level TII values were subsequently derived by aggregating the tile-based results.
In the second phase, district-level TII values were compared with a set of urban, socio-economic, geometric characteristics. These indicators were derived primarily from standardized open geospatial datasets, including the Polish Head Office of Geodesy and Cartography (GUGiK), supplemented by official demographic statistics where required. The use of openly available datasets was intended to ensure methodological transparency.
The statistical analysis aimed to identify relationships between thermal intensity and district characteristics. Pearson’s correlation coefficient was applied to examine linear relationships between continuous variables, while Spearman’s correlation coefficient was used to assess monotonic relationships that might not satisfy the assumptions of normality. Spatial dependence in thermal intensity was evaluated using Global Moran’s I, providing a measure of overall spatial autocorrelation across the study area. To identify statistically significant local clusters and spatial outliers, Local Indicators of Spatial Association (LISA) were calculated. Together, these analyses enabled the identification of districts exhibiting consistently high or low thermal intensity and revealed how thermal patterns relate to urban morphology, and socio-economic characteristics.
The overall methodological framework combines thermal remote sensing, spatial statistics, and open geospatial data within a reproducible workflow. By relying on standardized data sources and widely applicable analytical methods, the framework is designed to be transferable to other urban contexts, supporting comparative analyses and evidence-based planning for improving urban energy efficiency and identifying areas for further building-level investigation.

2.1. Case Study

The study area is the city of Gdynia (Figure 2), a port city on the southern Baltic coast in the Pomeranian Voivodeship, northern Poland, forming part of the Tricity metropolitan area together with Gdańsk and Sopot. Gdynia combines a dense central core and port infrastructure with extensive residential districts, industrial and logistic zones, and large peri-urban areas bordering the Tricity Landscape Park. The municipality is administratively divided into districts, which constitute the reporting units used in this study. This administrative division (21 districts) is used as the interpretive spatial frame for the analysis and is consistent across the district boundary layer and the socio-economic indicator source. Building footprints and attributes are taken from the national topographic database (BDOT10k) [20].
Figure 2. Functional structure of Gdynia.

2.2. Data Sources

The analysis is built on an existing thermographic product rather than on raw radiometric measurements. Night-time aerial thermographic imagery of Gdynia and neighbouring municipalities was acquired in March 2021 for the municipal district heating company OPEC (Okręgowe Przedsiębiorstwo Energetyki Cieplnej) and flown by MGGP Aero, and processed into a textured three-dimensional city model, delivered as 3MXB tiles in ETRS89/Poland CS2000 zone 6 (EPSG:2177) and dated June 2021. According to the project documentation that accompanies the dataset, the survey was flown on three nights with sub-zero air temperatures, using a nadir-looking thermal camera, with acquisition extending over several hours each night. The provider mosaicked the three nights into a single colour-mapped product draped onto a pre-existing photogrammetric mesh, in which roofs and ground are textured at approximately 0.2 m per pixel. No per-night radiometric data, flight logs or meteorological records were delivered, so no further harmonisation was possible.
The delivered scene covers both Gdynia and the neighbouring municipality of Rumia; the analysis was restricted to the administrative extent of Gdynia. Three conceptual constraints follow from this and define the scope of the study:
  • The source is radiometric and the delivered product is colour-mapped. The underlying capture is infrared (thermal) imagery, but the values available for analysis are extracted from colour-mapped, JPEG-compressed textures.
  • No direct pixel-level georeferencing. The textures are mapped to three-dimensional geometry through UV parameterisation. Each spatial tile is georeferenced as a discrete unit, but individual texture pixels are not directly georeferenced rasters, which precludes robust per-building pixel attribution without reconstructing the full texture–geometry–coordinate relationship.
  • Night-time surface thermal intensity reflects multiple factors (material thermal inertia, emissivity, geometry, and infrastructure) in addition to envelope heat loss. The index is therefore treated as a relative thermal intensity proxy.
District-level socio-economic indicators for 2024 were compiled from the Gdynia open-data sources. The official district boundary layer was used to define the administrative extent. Table 1 summarises the datasets used.
Table 1. Datasets used for the research.
The thermographic survey represents 2021 conditions, whereas the municipal socio-economic indicators refer to 2024. The bibliographic year 2026 for BDOT10k identifies the cited data source and does not establish the observation or construction year of every building polygon. A date-matched 2021 building inventory and complete feature-level historical update records were not available in the supplied analytical data. Therefore, changes to the building stock, vegetation, land cover and resident population between source dates cannot be excluded. Associations across these datasets are interpreted as exploratory spatial comparisons, not temporally synchronized measurements, causal effects or evidence of change over time.

2.3. Analytical Units and Construction of the Thermal Intensity Index

Two nested spatial units are used. The primary analytical unit is the thermal tile (approximately 300 × 300 m), the discrete georeferenced spatial cell into which the thermographic 3D model is partitioned. The analysis is computed at tile level, and the tile is the unit of statistical modelling, because, as noted in Section 2.2, the tile is the smallest georeferenced unit of the product. Thermal textures were extracted from the 3MXB tiles using the texture offsets recorded in each file.
The TII was constructed in three steps. (1) The JPEG textures of the most detailed level of detail available for at least 80% of the tiles (LOD 18) were extracted from the 3MXB files using the byte offsets declared in the file headers. (2) Pixels whose highest RGB channel value was ≤30 were excluded as near-black background or untextured gaps (e.g., occlusion by trees); this threshold lies far below the darkest colour of the thermal ramp (highest channel value 139), so no ramp colour is removed. (3) Because the thermal textures were provided in false colour without an accompanying temperature-to-colour calibration, a relative colour scale was reconstructed from the available imagery. Exploratory RGB diagnostics, including k-means clustering (k = 12), were performed to examine the colour distribution of the extracted textures. Eight RGB anchor colours (#0367C3, #10A959, #0CDF0A, #7BF109, #AAF606, #F6EE03, #F7C803, and #E83404) were arranged in an assumed cold-to-warm sequence, consistent with colour palettes used in thermographic and scientific visualization [22,23]. These colours were linearly interpolated in RGB space to generate a 256-level lookup table (LUT). Blue-start and cyan-start palette configurations were compared using normalized RGB-distance residuals, and the blue-start LUT was retained for the definitive analysis. During this exploratory reconstruction, pixels with max(R,G,B) ≤ 40 were excluded. The tile-level TII was calculated as the arithmetic mean of all sampled pixel scores pooled across the textures associated with each tile. Additional descriptive statistics, including the median and the 10th and 90th percentiles, were retained. District-level TII values were subsequently calculated as the unweighted arithmetic mean of the tiles assigned to each district.
Tiles are indivisible statistical units, so each tile was assigned in full to a single district. Assignment was performed by spatial overlay: a tile intersecting more than one administrative district was allocated to the district containing the largest area of intersection. Kamienna Góra illustrates the situation (Figure 3). The rule was checked against two alternatives, allocation by the district containing the tile representative point and a fractional allocation in which each tile contributes to every intersected district in proportion to the overlapping area. District means were effectively unchanged (Spearman ρ = 1.000 against the representative-point rule and ρ = 0.991 against fractional allocation). The maximum-overlap rule was therefore retained.
Figure 3. Tile geometry and building footprints in Kamienna Góra, the smallest district.
Individual building footprints from BDOT10k are used as an intermediate unit. They are required to derive the tile-level morphological indicators and to support descriptive summaries at district level.
The secondary analytical unit is the administrative district, used primarily for reporting and contextual interpretation because the 2024 socio-economic indicators available from the Gdynia municipal open-data portal are reported at this scale. District-level TII values were calculated as the unweighted mean of the tile TII across all tiles assigned to each district, so that every valid tile contributed equally. Several municipal indicators are absolute counts of facilities or entities, such as cinemas, theatres, libraries, and hospitals. These counts have no direct physical correspondence with the mixed surfaces represented by the tile-level TII and may also reflect district size, population, centrality, or administrative function. They were therefore included only in exploratory district-level screening and interpreted as contextual characteristics rather than as direct thermal factors.
After restricting the dataset to the administrative extent of Gdynia, the final analytical universe comprises 1107 thermal tiles and 26,789 building footprints. Of these tiles, 848 contain building footprints (built tiles).

2.4. Indicators at Tile and District Scales

Two distinct sets of indicators were used, corresponding to the two analytical scales of the study. Tile-level indicators describe local building morphology and composition, while district-level indicators represent broader structural and socio-economic characteristics.

2.4.1. Tile-Level Indicators

Morphological and compositional indicators were derived per tile from the building set: building count, footprint area statistics, footprint perimeter, built-up density, that is total footprint area divided by tile area (the tile-scale equivalent of the building footprint coverage used at district level), and the within-tile proportion of each building class. The 23-candidate tile-level indicators, together with the target variable, are listed in Table 2.
Table 2. Indicators derived from building dataset and thermal intensity index for the research.

2.4.2. District-Level Indicator Aggregation

District-level indicators combined morphological aggregates derived from the building dataset with socio-economic and land-cover indicators reported for 2024 through the Gdynia municipal open-data portal [21]. The district-level thermal target was calculated as the arithmetic mean of the tile-level ordinal thermal index across all unique tiles assigned to each district. Each tile therefore contributed equally to the district mean.
Four structural indicators were emphasised in the primary district-level interpretation because they describe the physical intensity or broader spatial context of urban development: building footprint coverage, forest cover, population density, and district area. Other municipal indicators, including demographic characteristics, housing-market variables, and counts of facilities or economic entities, were retained as contextual variables and examined only descriptively (Table 3).
Table 3. District-level indicators used in the interpretive analysis.

2.5. Correlation and Collinearity Screening

Screening for redundancy was applied only to the tile-level predictor set, since these are the variables that may enter a regression control in the next analysis step. The district-level indicators are used for description and interpretation rather than as predictors in a model, so they were not subjected to collinearity screening. The 23-candidate tile-level predictors were screened using pairwise correlation, interpretive redundancy and the variance inflation factor (VIF) [24]. Pairwise Pearson correlations were examined first to identify predictors carrying substantially overlapping information; when two variables were strongly correlated, the one with the clearer urban interpretation and lower redundancy against the remaining indicators was retained. VIF was then used to quantify how strongly the variance of each regression coefficient could be inflated by linear dependence among predictors: values close to 1 indicate little multicollinearity, whereas values above 5 are commonly treated as potentially problematic. The correlation structure of the screened set is shown in Figure 4.
Figure 4. Pairwise Pearson correlation matrix of the 14 screened tile-level predictors.
Screening reduced the 23 candidates to a final set of 14 tile-level predictors (Table 4). Within this set the maximum VIF is 2.54 and the largest absolute pairwise correlation is 0.636, so no predictor pair reaches 0.70 and multicollinearity is low.
Table 4. Variance inflation factors for the final 14-variable tile-level predictor set.

2.6. Spatial Autocorrelation and Regression Control

Global spatial autocorrelation of the tile-level index was measured with Moran’s I [25] over all 1107 tiles. Moran’s I summarises whether tiles with similar values are located near one another: values near zero indicate a random spatial arrangement, whereas positive values indicate that warm tiles adjoin warm tiles and cool tiles adjoin cool tiles. Local indicators of spatial association (LISA) [26] were computed with the same weights and permutation scheme, classifying each tile as high–high, low–low or a spatial outlier where the local statistic reached p < 0.05. Because LISA performs one test per tile, these local classifications are treated as exploratory rather than confirmatory. Spatial weights were defined using the eight nearest neighbours (k = 8) of tile representative points, row-standardized, with significance assessed through 999 permutations.
To establish whether building morphology accounts for the observed spatial structure, the 14 screened tile-level predictors were standardised and entered into an ordinary least squares regression of the tile-level TII over the 848 built tiles. The residuals of that regression, that is the part of each tile’s value not accounted for by its building morphology, were then tested for spatial autocorrelation using the same procedure, with the nearest-neighbour weights recomputed for this subset. The regression is used as a diagnostic control, not as a causal or predictive model.

3. Results

3.1. Spatial Pattern of the Thermal Index

The spatial distribution of the tile-level ordinal thermal index shows a broad dense centre and green periphery gradient across Gdynia. Higher ordinal values concentrate in the compact central as well as port and industrial areas, which at district level is characterised by greater building footprint coverage and population density. Lower values occur predominantly in larger peripheral districts with lower built-up density and more extensive forest and open-land coverage (Figure 5).
Figure 5. Tile-level ordinal thermal palette index across Gdynia (n = 1107 tiles), with district boundaries and building footprints for context. Relative index, not calibrated temperature.

3.2. Tile-Level Spatial Structure and Regression Control

At the tile scale, the ordinal thermal index shows strong and significant global spatial autocorrelation (Moran’s I = 0.673, p = 0.001), indicating that higher and lower index tiles form coherent spatial clusters rather than being randomly distributed (Figure 6).
Figure 6. Moran scatterplot of the tile-level ordinal thermal index.
Local indicators of spatial association (LISA) identify 247 high–high tiles, concentrated in the dense central and port districts, and 276 low–low tiles in the larger peripheral districts, together with 27 spatial outliers; the remaining 557 tiles are not significant at p < 0.05 (Figure 7). Because LISA involves one test per tile, these local classifications are treated as exploratory and are not interpreted as confirmatory inference.
Figure 7. Exploratory LISA cluster map of the tile-level ordinal thermal index.
To test whether building morphology accounts for this spatial structure, the final 14-variable tile-level predictor set was entered into an ordinary least squares control regression of the tile-level index over the 848 built tiles, and the spatial autocorrelation of the residuals was examined. The residual autocorrelation remains strong and significant (Moran’s I = 0.602, p = 0.001), indicating that substantial spatial structure persisted after controlling for the available building-morphology variables. This indicates that these predictors capture only part of the spatial variation represented in the ordinal thermal index and that additional spatially structured influences not included in the model may contribute to the remaining pattern. This regression is used solely as a control to assess residual spatial structure and is not presented as a predictive model.

3.3. District-Level Patterns

Tile-level TII values were aggregated to the 21 administrative districts. At this scale, the TII was positively associated with building footprint coverage (Spearman’s ρ = 0.74; 95% BCa CI: 0.39–0.90) and negatively associated with forest cover (ρ = −0.54; 95% BCa CI: −0.83 to −0.01). Associations with population density (ρ = 0.48) and district area (ρ = −0.46) were less certain, with confidence intervals including zero (Figure 8; Table 5).
Figure 8. District-level associations between the TII and four structural indicators (n = 21). Spearman’s ρ and exploratory 95% BCa bootstrap confidence intervals are shown. The intervals do not account for spatial dependence.
Table 5. Building-class composition and building footprint coverage across the 21 administrative districts of Gdynia.District-level associations between the Thermal Intensity Index (TII) and selected structural indicators in Gdynia (n = 21).
The association with building footprint coverage remained positive in leave-one-district-out analyses (ρ = 0.70–0.81). However, district-level TII values also exhibited spatial autocorrelation (Moran’s I = 0.30, p = 0.014). As the bootstrap confidence intervals do not account for spatial dependence, these findings are interpreted as exploratory spatial associations rather than causal relationships or evidence of building heat loss.

3.4. Building-Class Composition

Building-class composition was examined separately, but the interpretation of any class-related pattern is constrained by how much of each tile is actually occupied by buildings. Building footprint coverage, the share of a tile’s area covered by building footprints, is low throughout the city: across the municipality buildings cover 4.91% of the surface (Table 6), and among the 848 tiles that contain buildings the median coverage is 0.083, meaning that buildings occupy roughly 8% of the tile area while the remaining 92% is street, yard, parking area, bare ground or vegetation.
Table 6. Building-class composition and building footprint coverage across the 21 administrative districts of Gdynia.
Class shares were tested under the two definitions: by building count and by footprint area. The definition substantially changes how much territory is attributed to each class: the number of tiles in which multi-family residential buildings account for at least half of the composition rises from 90 under count share to 179 under footprint share. The associated thermal values, however, barely move. Therefore, no robust independent association with residential composition was detectable.
This finding is consistent with the spatial nature of the thermal product described in Section 2.2. Because the index summarizes all valid texture pixels associated with a tile, it cannot isolate the contribution of building roofs from that of paved surfaces, vegetation, infrastructure, or possible operational heat sources within the same tile. A building-specific assessment would therefore require georeferenced thermal information at a spatial resolution such as the pixel level that allows individual building surfaces to be isolated, together with building-level information on construction age, materials, heating systems, and energy use. Roof-level thermal information would improve attribution to individual buildings, although analysis of façades would also be desirable for a more complete assessment of building-envelope thermal behaviour.

3.5. Relative Thermal Intensity

The highest district-level ordinal thermal indices were recorded in Śródmieście (67.2) and Kamienna Góra (67.1), followed by Chylonia (60.6), Pogórze (60.2) and Wzgórze św. Maksymiliana (60.1). These districts represent compact central or consolidated urban profiles with comparatively high building footprint coverage. The lowest indices occurred in Wielki Kack (36.6), Pustki Cisowskie-Demptowo (40.4), Mały Kack (43.7) and Obłuże (44.7), which are larger or more peripheral districts with lower footprint coverage and greater forest or open-land cover (Figure 9). The pattern therefore reflects a broad contrast between dense central urban fabric and less densely developed peripheral areas. These relationships are interpreted as exploratory spatial associations rather than causal or inferential effects.
Figure 9. District-level relative thermal intensity, Gdynia.

3.6. Robustness and Sensitivity Analyses

Table 7 summarises the sensitivity of the TII to alternative processing and analytical choices. Texture-processing variants showed high agreement with the reference index (Spearman’s ρ = 0.97–0.99), including changes in the near-black pixel threshold, JPEG re-encoding, and the use of all valid pixels instead of random subsampling. Alternative district aggregation methods also produced similar rankings (ρ = 0.93–0.99), while fractional tile allocation showed strong agreement with the original assignment (ρ = 0.99). Spatial autocorrelation remained positive under different nearest-neighbour specifications, with Moran’s I ranging from 0.625 to 0.721 for the TII and from 0.558 to 0.659 for the OLS residuals. Overall, these results indicate that the main spatial patterns are relatively stable across the tested methodological choices.
Table 7. Sensitivity of the TII and of the main associations to processing and analytical choices.

4. Discussion

4.1. Spatial Structure and Urban Determinants of TII

The results indicate that TII in Gdynia is characterized by a pronounced spatial structure rather than a random distribution across the city. The global Moran’s I value of 0.673 indicates substantial positive spatial autocorrelation, meaning that areas with relatively high TII tend to be located near other high-intensity areas, while lower-intensity areas form their own spatial concentrations. This finding is important from a planning perspective, as it suggests that thermal characteristics should not be interpreted solely as properties of individual observations, but as part of broader spatial patterns associated with the organization of the urban environment. The identified clustering therefore supports the use of spatially explicit approaches when incorporating thermal remote-sensing information into district-scale urban and energy planning.
The district-level analysis further indicates that these spatial patterns correspond to broader differences in urban structure and land cover. Higher TII is most clearly associated with greater building footprint coverage, and lower values with greater forest cover; associations with population density and district area were weaker and less certain (Section 3.3). Taken together, these relationships suggest that the thermal index captures, at least in part, the contrast between more intensively urbanized and less intensively developed or more extensively vegetated parts of the city, consistent with the broader understanding that urban morphology, development intensity, and land cover contribute to spatial differentiation in urban thermal conditions [3,6,13].
These relationships should be interpreted as exploratory contextual associations rather than causal effects, given the limited number of districts (n = 21) and the ordinal nature of the thermal index. Relative thermal intensity may be influenced by building and ground materials, vegetation, thermal inertia, acquisition conditions and human activity as well as by envelope heat loss (Section 4.2); the index cannot separate these contributions.
At the district level, the approach is useful for identifying spatial clusters, comparing areas with different urban and social characteristics, and highlighting locations that may warrant further investigation, corresponding to the potential role of thermal remote sensing as a screening and decision-support tool in urban energy planning, rather than as a substitute for detailed building-energy assessment. In this sense, the contribution of the proposed framework lies primarily in connecting the spatial distribution of TII with the broader urban context and providing a reproducible method for prioritizing areas for subsequent analysis. The present district-scale framework and future building-scale analysis should therefore be regarded as complementary rather than interchangeable analytical levels: the former provides a city-wide overview capable of revealing spatial organization and relationships with urban structure, while the latter would enable investigation of the physical and energy-performance mechanisms underlying these patterns. The direction of the district-level associations is consistent with established findings from satellite and airborne studies, in which denser development is associated with higher surface temperatures and vegetation with lower ones [3,6,13,16]. The study does not present this relationship as new. Its contribution is the evidence on a colour-mapped, uncalibrated municipal product, whose index is stable across processing and aggregation choices (ρ = 0.93–0.99; Table 7), and on the scale dependence of its associations (Section 3.4; contributions listed in Section 1). This consistency with earlier work is a plausibility check, not a validation. To our knowledge, no comparable neighbourhood-level analysis exists for Gdynia.

4.2. Other Factors Influencing the Observed Thermal Patterns

The TII reflects the apparent surface radiance of everything visible in a tile, not only building envelopes, and several factors other than heat loss may independently shape the observed patterns.
Building materials and surface properties: Roof and ground materials differ in emissivity, colour and thermal conductivity, so two surfaces at the same physical temperature can be rendered differently, and a well-insulated dark or metallic roof may appear different from a poorly insulated one for reasons unrelated to insulation. These properties were not available for individual buildings in this study.
Vegetation and land cover: Vegetation, bare ground, water and paved surfaces differ in thermal inertia, moisture content and emissivity. The negative association between the TII and forest cover (ρ = −0.54) may therefore reflect the thermal behaviour of vegetated surfaces, and tree canopy may also hide the surfaces beneath it. Pixels were excluded where textures were missing, so occlusion by trees may contribute to the lower values in forested districts. The association should not be read as an effect of building envelopes. Thermal inertia and acquisition conditions. Night-time surfaces release stored heat at different rates depending on their mass and exposure. The three survey nights were mosaicked without per-night radiometric data, flight logs or meteorological records, so differences in time of acquisition, air temperature, wind, surface moisture or snow cover between parts of the city cannot be excluded as contributors to the spatial pattern.
Human activities and infrastructure: In dense or industrial areas, warm surfaces may result from traffic, port and industrial operations, ventilation outlets, heated yards, parking areas or buried or exposed district-heating infrastructure, none of which is envelope heat loss. Two results in this study are consistent with these cautions. First, spatial autocorrelation of the residuals remained strong after controlling for 14 building-morphology variables (Moran’s I = 0.602), indicating that spatially structured influences not captured by building geometry contribute to the pattern. Second, no robust association with building-class composition was detected (Section 3.4), and buildings cover only about 8% of the median built tile, so the index is dominated by non-building surfaces. The associations reported here should therefore be read as descriptions of where relative surface thermal signals are higher or lower, not as evidence that building envelopes are the cause, and they cannot be separated from these other factors with the present data.

4.3. Implications for Screening and Prioritisation in Energy-Efficient Planning

The TII reflects the factors discussed in Section 4.2 as well as envelope heat loss. The suggestions below are therefore hypothetical uses of the index as a screening layer. The TII can help identify districts where more detailed investigation may be worthwhile, but it cannot on its own determine which buildings need energy-efficiency interventions or which measures (insulation, glazing, thermal-bridge reduction, heating upgrades) are appropriate. This analysis does not validate any specific retrofit recommendation.

4.3.1. Energy-Efficient Urban Planning

GIS-based approaches are effective for assessing urban retrofit processes and environmental performance across large areas using remote-sensing data [27]. The TII could be added as a thermal screening layer within Gdynia’s GIS-based planning infrastructure, alongside zoning, land-registry and building-age data, to support revisions of local spatial development plans (Miejscowy Plan Zagospodarowania Przestrzennego). Districts of elevated relative thermal intensity, such as Kamienna Góra, Śródmieście and Chylonia, could then be prioritised for more detailed assessment. Because the TII is ordinal and relative, any screening categories (e.g., low, medium, high, very high) would need limits defined from its distribution, for example quartiles of tile or district values, rather than absolute thresholds. These categories would indicate priority for further assessment only; they do not indicate that any building requires intervention [28]. The ranking also needs care at the top end: Kamienna Góra (67.1) is among the highest districts but comprises only nine tiles (Figure 3), so its value rests on few observations.
Compared with existing planning inputs, such as energy audits, energy performance certificates, and metered district-heating consumption, the TII provides a complementary city-wide, spatially continuous layer derived from an existing municipal thermal survey. Its added value lies in supporting preliminary spatial screening rather than replacing established energy assessment methods. The study did not evaluate whether TII-based prioritisation corresponds to or improves upon prioritisation based on these existing sources. Validation against metered energy consumption or energy performance certificate data, as proposed in Section 6, would therefore be an essential first step towards assessing its practical applicability.

4.3.2. Use in Retrofit Prioritisation

Where building-level audits in districts of elevated relative thermal intensity confirm envelope losses, retrofit programmes could consider additional wall and roof insulation in line with WT 2021 [29,30], replacement of old glazing, and treatment of thermal bridges. The U-values in these sources are regulatory benchmarks and were not compared with any building in this study.
Previous studies have used high-resolution surface temperature data to identify buildings at risk of thermal stress and prioritise them for energy audits [28], and have developed composite indices combining thermal performance, population density and building characteristics for city-level modernisation planning [27]. In future work, the TII could be combined with population density and building age and type data in a framework of this kind, after validation against building-level data.
The Czyste Powietrze (Clean Air) programme supports thermal modernisation, in-cluding wall insulation, window and door replacement and heating-source replace-ment [31]. Previous research has examined the economic and ecological benefits of thermal modernisation investments financed through support programmes in Poland [32]. TII-based screening could help the municipality decide where to focus information and outreach for the programme, with eligibility and measures determined at building level.

4.3.3. Sustainable Urban Development

From a sustainable urban development perspective, this study supports two modest uses: indicating where greening and monitoring could be considered for later testing, and providing a basis for repeated, comparable screening over time.
The evidence on vegetation is indirect. The TII was negatively associated with forest cover (ρ = −0.54; 95% BCa CI −0.83 to −0.01), and the lowest values occurred in Wielki Kack, Pustki Cisowskie-Demptowo, Mały Kack and Obłuże, which combine low footprint coverage with extensive forest or open land (Section 3.5). However, the interval nearly reaches zero, the sample is small (n = 21), and the index also mixes vegetation with other surfaces and with tree occlusion (Section 4.2). The association therefore does not show that vegetation lowers thermal intensity, and no cooling effect can be quantified here. Evidence that green infrastructure can reduce surface and air temperatures [33] is context, not support for a specific intervention. The results support only a hypothesis for later testing with calibrated data: that the effect of additional greening could be examined in districts with among the highest TII values (Section 3.5) and comparatively high footprint coverage (Śródmieście, Kamienna Góra, Chylonia; Table 6). The choice between ground-level planting, green roofs or vertical greening would depend on local conditions not analysed here.
At tile level, the 247 high–high tiles are concentrated in the central and port districts (Figure 7), so a first round of detailed assessment could start there. Because residual autocorrelation remained strong after controlling for building morphology (Moran’s I = 0.602), cluster membership should not be attributed to building characteristics.
Finally, the study used a single survey (March 2021), mosaicked from three nights without per-night radiometric data, flight logs or meteorological records. Using the TII as a longitudinal indicator would therefore require repeat surveys with calibrated, pixel-georeferenced imagery and documented acquisition conditions, validated against independent data such as metered district-heating consumption or energy performance certificates (Section 6). Used in this way, the TII can help planners decide where to direct limited assessment resources first.

5. Limitations

The TII is reconstructed from a colour-mapped, JPEG-compressed rendering rather than from radiometric measurements. As the original colour-to-temperature mapping was not provided, the preservation of relative thermal ordering is assumed rather than established. It is therefore ordinal and combines surface temperature with emissivity, viewing geometry and wind exposure, and it cannot be interpreted as calibrated temperature or heat loss. Building materials, roof colour and emissivity, vegetation and surface moisture, thermal inertia, snow cover and human or infrastructure heat sources (Section 4.2) may independently affect the index, and none could be controlled. Because the textures are not georeferenced at pixel level, the tile (≈300 m) is the smallest analytical unit; the index mixes roofs, paved and ground surfaces and vegetation, and building-level attribution is not possible. The datasets refer to different reference dates (2021, 2024 and 2026). This mainly affects year-specific socio-economic conditions, which are used only as context. The district-level analysis was limited to 21 spatially autocorrelated units. Although BCa bootstrap confidence intervals and leave-one-district-out analyses were used to assess uncertainty and stability, the confidence intervals do not account for spatial dependence. Therefore, the reported associations should be interpreted as exploratory rather than as evidence of causal relationships or building heat loss. Finally, because no calibrated temperatures or building-level energy-consumption data were available, the index could not be validated and the study does not validate any specific retrofit measure.
As the thermal dataset was processed into a single colour-mapped mosaic, the absence of original radiometric data, flight logs, and meteorological records limited the ability to account for variations in acquisition conditions across the three survey nights. A building-level assessment would require radiometrically calibrated, pixel-georeferenced imagery with documented acquisition times, combined with information on construction period, materials, renovation status, heating systems and energy use.

6. Conclusions

The study demonstrates a procedure for deriving and analysing a relative Thermal Intensity Index from an existing municipal 3D thermographic product. The resulting index supports exploratory identification of spatial thermal patterns across the surveyed urban areas and their comparison with urban structural characteristics. However, the observed associations depend on the scale of analysis and should not be interpreted as evidence of building-level thermal performance. In answer to the research questions, the index was stable to processing choices (RQ1), showed strong spatial structure that persisted after controlling for building morphology (RQ2), and was associated mainly with building footprint coverage and forest cover at district level, with wide uncertainty (RQ3); these associations are consistent with earlier work, and the contribution lies in showing how far a colour-mapped municipal product supports such analysis, and at which scale.
District-scale and tile-scale thermal screening can help identify spatial contrasts, relate them to urban structure and environmental context, and narrow the areas requiring closer investigation. Building-level assessment, using radiometrically calibrated, pixel-georeferenced thermal data together with detailed building information, remains necessary to evaluate thermal performance, determine which buildings need intervention and decide which measures are appropriate. The two levels are complementary, and the wider value of the approach lies in enabling city-wide screening while keeping the limits imposed by spatial scale and data structure explicit.
Accordingly, high-TII areas such as Śródmieście and Kamienna Góra are candidates for further investigation, but the index alone cannot show whether a high value stems from building envelopes, thermal bridges, heating systems, surface materials, vegetation, paved surfaces, human activity or other processes.
Future work should validate the TII against calibrated thermal data or independent building-energy information, such as metered district-heating consumption or energy performance certificates, and should use pixel-georeferenced imagery combined with building-level data, to move from the recognition of urban thermal patterns to the assessment of building-specific thermal performance.

Author Contributions

Conceptualization, R.H.-C., B.B.K. and D.K.-Z.; methodology, R.H.-C. and D.K.-Z.; software, R.H.-C.; formal analysis, R.H.-C.; resources, D.K.-Z.; data curation, R.H.-C.; writing—original draft preparation, R.H.-C., B.B.K. and D.K.-Z.; writing—review and editing, R.H.-C., B.B.K. and D.K.-Z.; visualization, R.H.-C.; supervision, D.K.-Z. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The aerial thermographic data used in this study were made available for research purposes and are subject to provider restrictions; therefore, they are not publicly available. The municipal and national open datasets used in the analysis are available from the respective sources cited in the manuscript.

Acknowledgments

The authors thank OPEC (Okręgowe Przedsiębiorstwo Energetyki Cieplnej) and Konrad Klepacki for granting access to the aerial thermographic data used in this research. The content was prepared by the authors, while the graphical form of the Figure 1 was developed with the assistance of ChatGPT-6.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. United Nations. Transforming Our World: The 2030 Agenda for Sustainable Development. 2015. Available online: https://docs.un.org/en/A/RES/70/1 (accessed on 9 July 2026).
  2. International Energy Agency. Buildings. 2024. Available online: https://www.iea.org/energy-system/buildings (accessed on 9 April 2026).
  3. Rodríguez-Gómez, F.; Fernández-Cañero, R.; Pérez, G.; Del Campo-Ávila, J.; López-Rodríguez, D.; Pérez-Urrestarazu, L. Detection of unfavourable urban areas with higher temperatures and lack of green spaces using satellite imagery in sixteen Spanish cities. Urban For. Urban Green. 2022, 78, 127783. [Google Scholar] [CrossRef] [Scilit]
  4. Oke, T.R. The energetic basis of the urban heat island. Quart. J. R. Meteoro Soc. 1982, 108, 1–24. [Google Scholar] [CrossRef] [Scilit]
  5. Arnfield, A.J. Two decades of urban climate research: A review of turbulence, exchanges of energy and water, and the urban heat island. Int. J. Climatol. 2003, 23, 1–26. [Google Scholar] [CrossRef] [Scilit]
  6. Santamouris, M. Recent progress on urban overheating and heat island research. Integrated assessment of the energy, environmental, vulnerability and health impact. Synergies with the global climate change. Energy Build. 2020, 207, 109482. [Google Scholar] [CrossRef] [Scilit]
  7. Prata, A.J.; Caselles, V.; Coll, C.; Sobrino, J.A.; Ottlé, C. Thermal remote sensing of land surface temperature from satellites: Current status and future prospects. Remote Sens. Rev. 1995, 12, 175–224. [Google Scholar] [CrossRef] [Scilit]
  8. Ministry of Development and Technology. Long-Term Renovation Strategy for Buildings: Supporting the Renovation of the National Building Stock. 2022. Available online: https://www.gov.pl/attachment/5720cb23-15d2-473d-829f-ff1010c89ecc (accessed on 9 July 2026).
  9. Ministry of Development and Technology. Krajowy Plan Renowacji Budynków [National Building Renovation Plan] (Draft). 2024. Available online: https://www.gov.pl/web/rozwoj-technologia (accessed on 9 July 2026).
  10. European Parliament and Council of the European Union. Directive (EU) 2024/1275 of the European Parliament and of the Council of 24 April 2024 on the Energy Performance of Buildings (Recast). Official Journal of the European Union, L 2024/1275. 2024. Available online: https://eur-lex.europa.eu/eli/dir/2024/1275/oj (accessed on 9 July 2026).
  11. Weng, Q.; Quattrochi, D.A. Thermal remote sensing of urban areas: An introduction to the special issue. Remote Sens. Environ. 2006, 104, 119–122. [Google Scholar] [CrossRef] [Scilit]
  12. Kuenzer, C.; Dech, S. (Eds.) Thermal Infrared Remote Sensing: Sensors, Methods, Applications. In Remote Sensing and Digital Image Processing; Springer: Dordrecht, The Netherlands, 2013; Volume 17. [Google Scholar] [CrossRef] [Scilit]
  13. Voogt, J.A.; Oke, T.R. Thermal remote sensing of urban climates. Remote Sens. Environ. 2003, 86, 370–384. [Google Scholar] [CrossRef] [Scilit]
  14. Weng, Q. Thermal infrared remote sensing for urban climate and environmental studies: Methods, applications, and trends. ISPRS J. Photogramm. Remote Sens. 2009, 64, 335–344. [Google Scholar] [CrossRef] [Scilit]
  15. Bitelli, G.; Conte, P.; Csoknyai, T.; Franci, F.; Girelli, V.; Mandanici, E. Aerial Thermography for Energetic Modelling of Cities. Remote Sens. 2015, 7, 2152–2170. [Google Scholar] [CrossRef] [Scilit]
  16. Zhou, D.; Xiao, J.; Bonafoni, S.; Berger, C.; Deilami, K.; Zhou, Y.; Frolking, S.; Yao, R.; Qiao, Z.; Sobrino, J.A. Satellite Remote Sensing of Surface Urban Heat Islands: Progress, Challenges, and Perspectives. Remote Sens. 2018, 11, 48. [Google Scholar] [CrossRef] [Scilit]
  17. Reinhart, C.F.; Davila, C.C. Urban building energy modeling—A review of a nascent field. Build. Environ. 2016, 97, 196–202. [Google Scholar] [CrossRef] [Scilit]
  18. Chen, L.; Zheng, Y.; Yu, J.; Peng, Y.; Li, R.; Han, S. A GIS-Based Approach for Urban Building Energy Modeling under Climate Change with High Spatial and Temporal Resolution. Energies 2024, 17, 4313. [Google Scholar] [CrossRef] [Scilit]
  19. Oltra-Carrió, R.; Sobrino, J.A.; Franch, B.; Nerry, F. Land surface emissivity retrieval from airborne sensor over urban areas. Remote Sens. Environ. 2012, 123, 298–305. [Google Scholar] [CrossRef] [Scilit]
  20. Główny Urząd Geodezji i Kartografii, “Baza Danych Obiektów Topograficznych (BDOT10k): Gdynia (TERYT 2262)” 2026. Available online: https://www.gov.pl/web/rozwoj-technologia/prekonsultacje-projektu-krajowego-planu-renowacji-budynkow (accessed on 9 July 2026).
  21. City of Gdynia, “Otwarte Dane Gdynia: Wskaźniki Dzielnicowe”. 2024. Available online: https://otwartedane.gdynia.pl/ (accessed on 14 May 2026).
  22. Sousa, M.J.; Moutinho, A.; Almeida, M. Thermal Infrared Sensing for Near Real-Time Data-Driven Fire Detection and Monitoring Systems. Sensors 2020, 20, 6803. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Ware, C.; Stone, M.; Szafir, D.A. Rainbow Colormaps Are Not All Bad. IEEE Comput. Graph. Appl. 2023, 43, 88–93. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. Salmerón Gómez, R.; Rodríguez Sánchez, A.; García, C.G.; Pérez, J.G. The VIF and MSE in Raise Regression. Mathematics 2020, 8, 605. [Google Scholar] [CrossRef] [Scilit]
  25. Yamada, H. Moran’s I for Multivariate Spatial Data. Mathematics 2024, 12, 2746. [Google Scholar] [CrossRef] [Scilit]
  26. Anselin, L. Local Indicators of Spatial Association—LISA. Geogr. Anal. 1995, 27, 93–115. [Google Scholar] [CrossRef] [Scilit]
  27. Kazemian, A.; Xiang, C. City-scale rooftop retrofit prioritization: Linking thermal performance, energy impacts, urban morphology, and population exposure. Appl. Energy 2026, 406, 127304. [Google Scholar] [CrossRef] [Scilit]
  28. Alsharif, A.M.; Almajadiah, A.M.; Alzahrani, M.; Lagebo, M.L.; Andiye, Y.M. Deep learning-based thermal mapping for enhanced urban heat management and cooling energy reduction in Arid Saudi Arabian environments. Sci. Rep. 2026, 16, 19260. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Choromański, J. “New Energy Performance Standards for Buildings—Standard WT 2021,” Miller Canfield. Available online: https://millercanfield.pl/en/new-energy-performance-standards-for-buildings-standard-wt-2021/ (accessed on 9 July 2026).
  30. Polish Residential Energy Efficiency Financing Facility (Institutional Mode Toggle), “Docieplenie Ścian, Dachu i Podłóg,” PolREFF. Available online: https://ebrdgeff.com/poland_facilities/ (accessed on 9 July 2026).
  31. Ministerstwo Rozwoju i Technologii. Narodowy Program Mieszkaniowy (National Housing Program). 2025. Available online: https://www.gov.pl/web/rozwoj-technologia/narodowy-program-mieszkaniowy (accessed on 9 July 2026).
  32. Adamczyk, J.; Dylewski, R. Economic and Ecological Benefits of Thermal Modernization of Buildings Related to Financing from Aid Programs in Poland. Energies 2026, 19, 260. [Google Scholar] [CrossRef] [Scilit]
  33. Lin, H.; Li, X. The Role of Urban Green Spaces in Mitigating the Urban Heat Island Effect: A Systematic Review from the Perspective of Types and Mechanisms. Sustainability 2025, 17, 6132. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.