Abstract
In finite-control-set model predictive current control (FCS-MPCC) of permanent magnet synchronous motors (PMSMs), errors in the nominal motor parameters and delays in applying switching commands can degrade current tracking. The proposed controller combines a two-step predictor with an adaptive composite sliding mode disturbance observer (ACSMDO). The plant model groups parameter deviations and load changes into electrical and mechanical disturbance channels. At each sample, the observer supplies one-step estimates of the currents, electrical speed, and disturbances. The predictor starts from these estimates, evaluates candidate voltages using the predicted speed and disturbances, and holds the current references in the synchronous frame. MATLAB/Simulink version 2024b tests across eight parameter-mismatch cases yielded a 28.6% reduction in the mean joint current-tracking root mean square error relative to conventional FCS-MPCC. In the matched-gain comparison under increased combined mismatch, the adaptive reaching law also reduced the peak q-axis tracking error.
1. Introduction
1.1. Motivation
Permanent magnet synchronous motors (PMSMs) combine a compact structure with high power density and fast dynamic response [1]. Their use in electric traction [2,3] motivates control strategies that maintain the commanded response as operating conditions change. Recent traction studies have considered both predictive and field-oriented control [4,5].
1.2. Related Research
The electrical and mechanical dynamics of a PMSM are nonlinear and coupled. In field-oriented control (FOC), the current loop is nested inside the speed loop, and proportional–integral (PI) regulation supports accurate tracking in steady state [6]. Tracking errors can increase if the plant parameters or load depart from those used for tuning. Direct torque control (DTC) selects an inverter state from hysteresis decisions on estimated torque and flux, providing a fast response with a simple controller. Its switching decisions can also cause current and torque ripple. Duty-cycle control has been used to alleviate torque and flux ripple [7]. Alternative designs include internal model control [8,9], sliding mode control [10,11], and predictive control [12,13].
The cited internal-model designs use a fuzzy adaptive speed regulator or a generalized inverse model. Sliding-mode speed controllers have modified the reaching law and have used smooth super-twisting disturbance estimation [14]. The present observer places the switching injection inside the current-prediction loop, where its effect can be isolated through a matched-gain comparison.
Model predictive control (MPC) forecasts the drive response to feasible inputs using a sampled model. Minimizing a cost over the available actions lets the designer account for constraints and dynamic performance [15]. The choice of controlled variables distinguishes model predictive torque control (MPTC) from model predictive current control (MPCC). In MPTC, the objective typically weights torque error against flux-linkage error [16,17]. The choice of input set is a separate distinction. Continuous-set MPC (CCS-MPC) optimizes a continuous command [18,19] and can use a modulator at fixed switching frequency. Finite-control-set MPC (FCS-MPC) evaluates discrete inverter actions [1]. Selecting a single voltage vector per sample allows space-vector pulse-width modulation to be omitted. The switching frequency is generally variable, and the available voltage vectors affect current and torque ripple [1].
Continuous-set variants incorporate disturbance estimation into the commanded voltage or flux. Reduced-order observation has been used for deadbeat stator-flux control [18], and extended state observers and augmented prediction models have been investigated for dual three-phase machines [20,21,22]. Continuous-set controllers for asymmetrical six-phase drives have also addressed system nonidealities [23] and fault-tolerant operation [24].
For FCS-MPC, virtual voltage vectors can refine the available actuation [25], while a fast vector search can reduce the cost of two-step prediction [26]. Multistep prediction has also been studied for drives with reduced dc-link capacitance [27]. A separate implementation issue is the delay between computation and application of an inverter state. In standard two-step compensation, the first prediction uses the state already committed to the inverter [28]. These changes affect the voltage used for prediction or the set available for selection. Errors in the motor model can still propagate through both steps.
When the motor resistance, inductance, or magnet flux linkage differs from its nominal value, model-based control can lose accuracy and stability margins. The incremental MPCC predictor in [29] cancels the permanent-magnet flux term and uses a disturbance observer to compensate for inductance mismatch. Its prediction was reported to be more sensitive to inductance errors than to resistance errors. Another incremental MPCC design accounts for inductance variation and synthesizes a virtual voltage vector to improve steady-state behavior [30]. Cancellation of the flux-linkage term in these models leaves separate effects from resistance and inductance. Current-error compensation has been paired with online inductance or parameter identification in deadbeat current controllers [31,32]. Cascaded predictive control has also addressed parameter errors in both the speed and current loops [33]. Other approaches estimate inductance online [34] or model machine parameters using physics-informed methods [35].
A model-free predictive current controller replaces the parameterized motor equations with an ultralocal model and uses an extended state observer to estimate the unmodeled dynamics [36]. That design was assessed in terms of current harmonics, tracking error, and transient overshoot. Related work has used cascaded extended state observers [37] and has compensated for inverter nonlinearity and time-varying parameters [38]. Other predictive designs address harmonic suppression [39,40], loss minimization [41], or adjustment of the prediction horizon [42].
Model-free current prediction has also been combined with virtual-vector modulation in surface-mounted and dual three-phase machines [43,44]. In dual three-phase drives, other objectives include modulation-pattern optimization [45], harmonic back-EMF identification [46], and torque enhancement [47]. Sensorless predictive control has separately addressed the estimation of speed or position [48,49,50] and operation without current sensors [51]. The observer in this study uses the sampled current and electrical speed to estimate lumped disturbances.
A composite sliding-mode observer has been used to estimate disturbances for a delay-compensated deadbeat controller, with a modulator applying the corrected voltage command [52]. A compensated deadbeat predictive current controller (CDPCC) likewise uses a composite sliding mode disturbance observer (CSMDO). It assigns parameter and load deviations to lumped terms in the current and speed loops and compensates for their estimates to improve tracking and robustness [53]. Moving-horizon estimation has also been used in dual three-phase current control with harmonic suppression [54]. Changes in magnet flux linkage, rotor inertia, or load torque can affect the one-step electrical-speed estimate. Section 5.4 evaluates how the speed used in the second step affects current prediction.
In observer-based FCS-MPCC, EV2-MPCC with an improved sliding-mode observer uses electrical disturbance estimates to correct the reference voltage before extended-vector selection [55]. Adaptive integral extended state observation has been combined with sector-based multistep prediction and inductance estimation [56]. The present method estimates the electrical and mechanical disturbances within the same observer, keeps the eight basic switching states, and propagates the one-period actuation schedule using the applied voltage in the first step. The second step evaluates the voltage candidates in the predicted rotor frame against synchronous current commands. Section 5 separates the influence of the reaching law, the reference treatment, and the actuation delay. It also quantifies the effect of predicted electrical speed on the same trajectory.
1.3. Contributions
This article establishes a composite mathematical model that treats parameter mismatch and load torque changes as lumped disturbances. The ACSMDO supplies the next-step current and disturbance estimates to the delay-compensated predictor. These disturbance estimates are included in the second-step current calculation. The switching decision evaluates the existing current-error cost with reference currents held in synchronous coordinates.
This work makes four contributions.
- (1)
- The FCS-MPCC control strategy based on ACSMDO constructed in this paper retains direct selection among the eight basic switching states and accounts for a one-period actuation delay.
- (2)
- The composite model collects parameter errors and variations in load torque into lumped terms used in the two-step current prediction.
- (3)
- A discrete ACSMDO supplies next-step current and disturbance estimates for the delay-compensated predictor. These estimates were incorporated into the predictive current calculation, which accounts for the applied voltage in the first prediction step and the candidate voltage in the second step. The observer analysis establishes continuous-time convergence for constant lumped disturbances and a local sampled-data error bound under the stated conditions.
- (4)
- Compared with conventional CSMDO, ACSMDO uses an adaptive sliding mode approach law, whose switching term is continuous at the sliding surface. Matched-gain simulation isolates its contribution to tracking after a load step.
1.4. Article Organization
2. Mathematical Model of PMSM
For the surface-mounted PMSM (SPMSM), the model uses the same effective inductance on both axes, L = Ld = Lq. The model assumes balanced windings and sinusoidal back electromotive force. The simulations represent the inverter by ideal switching states and vary the effective motor parameters within this model. Pronounced magnetic saturation, spatial harmonics, and inverter dead time require additional modeling. Equation (1) gives the stator current dynamics.
In the dq frame, ix and ux are the stator current and voltage for axis x, with x equal to d or q. The parameters L and R denote stator inductance and resistance. The symbols ψf and ωe denote permanent-magnet flux linkage and electrical angular velocity, respectively.
The rotor dynamics relate electrical angular acceleration to the electromagnetic torque, load torque, and viscous damping. This balance is given by (2).
where Pn, J, B and TL represent the number of pole pairs, rotational inertia, damping coefficient, and load torque, respectively.
Combining Equations (1) and (2), the composite mathematical model of SPMSM in this paper is expressed as
3. Finite Set MPCC
3.1. Traditional FCS-MPCC
Conventional FCS-MPCC starts from the electrical subsystem in (3). The forward-Euler update in (4) advances the sampled currents from k to k + 1.
The index k identifies the present sample. The prediction at k + 1 lies one sampling interval Ts later.
At each control interval, the two-level voltage source inverter (2L-VSI) admits eight switching states. Figure 1 shows the corresponding basic voltage vectors u0 through u7.
Figure 1.
Basic voltage vector diagram.
For the nominal implementation schedule, the switching state selected at sample k is applied at k + 1 [28]. The two-step prediction accounts for this one-period actuation delay.
Equation (4) propagates the measurements at sample k to the first-step currents id(k + 1) and iq(k + 1). A second update yields the current prediction at k + 2 given in (5).
In the conventional FCS-MPCC approach, the assumptions regarding the reference current are as follows:
Equation (7) evaluates the delay-compensated predictions against the reference currents.
The controller selects the basic voltage vector that minimizes (7). Figure 2 shows how this decision fits into the conventional delay-compensated controller.
Figure 2.
Conventional FCS-MPCC with one-period actuation-delay compensation.
For the update from k + 1 to k + 2, the conventional predictor in (5) and Figure 2 uses the electrical speed sampled at k, ωe(k).
3.2. Parameter Sensitivity Analysis
Equation (8) extends the composite model in (3) to include deviations in motor parameters and load torque.
The quantities ∆R, ∆L, ∆J, ∆B, and ∆ψf describe deviations in resistance, inductance, rotor inertia, viscous damping, and magnet flux linkage, in that order.
Rewrite Equation (8) as
In (9), fd and fq aggregate the electrical model errors along the two axes. The term fω collects deviations in the speed dynamics, including the effect of load variation. Equation (10) gives the expressions for these disturbances.
Equation (10) gives the electrical and mechanical components of the lumped disturbance due to parameter mismatch and load variation.
At the same sampled state and applied voltage, the mismatched and nominal first-step Euler current predictions differ by . Resistance mismatch changes the current-dependent terms in both axes. Inductance mismatch also changes the voltage-to-current gain, so the electrical disturbance can change abruptly at inverter switching. Flux-linkage mismatch affects the back EMF in the q axis and the electromagnetic torque.
The sensitivity of the two-step current prediction to the electrical speed follows by evaluating the second Euler step at two speed inputs while holding the first-step current estimates, the candidate synchronous-frame voltage, and the electrical disturbance estimates fixed. The resulting current difference is
where δidq(k + 2) and δωe(k + 1) denote the differences in the predicted current vector and the speed input, respectively, taken in the same order. The first-step current estimates and in the d and q axes are common to both evaluations. Variations in inertia, damping, or load torque perturb the mechanical disturbance by δfω(k), changing the first-step electrical speed by Tsδfω(k). Under the same fixed-input conditions, this perturbation contributes to the two-step current prediction through (11) at order .
4. Extended Set FCS-MPCC with ACSMDO
Figure 3 shows the overall controller structure. At sample k, the ACSMDO uses the sampled currents and electrical speed together with the applied voltage for the first prediction step. The second step evaluates the eight candidate switching states against the current reference held in the synchronous frame. The selected state is applied at sample k + 1.
Figure 3.
Signal flow in the proposed observer-based predictive controller with a one-period actuation delay.
4.1. Proposed ACSMDO
According to Equation (9), considering the lumped disturbance, the prediction equation for current and electrical angular velocity is expressed as
The quantities Fd, Fq, and Fω denote the time derivatives of their respective disturbance components. The observer in (13) adds correction terms to estimate the currents, electrical speed, and disturbances in (12).
A hat denotes an estimate. The terms Vdsmo, Vqsmo, and Vωsmo are the sliding-mode injections. The gains Cd, Cq, and Cω scale those injections in the respective disturbance channels.
Subtracting the plant dynamics in (12) from the observer dynamics in (13) gives the error model in (14).
The current, speed, and disturbance errors in (14) are defined by , , , , , and . The observer uses the linear sliding surfaces given by (15).
The reaching law shapes the approach to the sliding surface and affects both the observer estimates and closed-loop tracking. Equation (16) gives the fixed-gain law used for the CSMDO baseline.
With fixed gains in (16), the switching term remains discontinuous near the sliding surface. The ACSMDO uses an adaptive reaching term that is continuous at zero. For j ∈ {d,q,ω}, let xd = id, xq = iq, and xω = ωe. Define and , with sd = ed, sq = eq, and sω = eω. Let ad = aq = R/L and aω = 0. In the current channels, (13) uses the estimated current in the resistive term. The adaptive injection is
where rj = |sj|/s0j, k1j,k2j > 0, 0 < α < 1, and β > 0. The scales s0d = s0q = 1A and s0ω = 1 rad/s reproduce the numerical convention used in the controller. The switching gain of the second term in (17) is N(sj) = k2j|sj|/h(rj), with N(0) = 0. The term N(sj)sgn(sj) is continuous at zero. Since h(0) = 1, it is locally proportional to sj. The comparison with the fixed reaching law in (16) depends on both terms in (17), including its error-dependent denominator and the selected gains.
4.2. Observer-Error Analysis
The lumped disturbance fj in (10) is bounded on operating regions with bounded currents, speed, applied voltages, load torque, and parameter deviations, provided that the actual inductance and inertia are bounded away from zero. On intervals where fj is differentiable, let .
Subtracting (9) from (13) gives and . At sj = 0, the state-error derivative is . For Cj > aj, set bj = Cj(Cj − aj) and introduce . Differentiating this coordinate gives , and the coupled error dynamics are
where . Since h(r) ≤ 1 + r for r ≥ 0, the coefficient multiplying sj in ϕj(sj) is bounded below by . When , .
Consider the quadratic Lyapunov function:
Differentiating (19) along (18) gives
For constant lumped disturbances, Fj = 0 and the bound in (20) is negative definite under the stated gain conditions. The origin of (18) is therefore asymptotically stable, and the disturbance-estimation error converges to zero.
For the noiseless sampled observer, write the actual plant update as xj(k + 1) = xj(k) + Ts[gj(k) + fj(k)] + ϵj(k), where ϵj(k) denotes the one-step plant residual and gj(k) is the nominal drift in (9) evaluated at the sampled state and applied voltage. The Euler update of (13) gives
where is the transformed error vector, Δfj(k) = fj(k + 1) − fj(k) is the disturbance increment, and is extended continuously to zero sliding error. The increment includes changes at inverter switching and load steps. The matrix I in (21) is the identity of order two.
On |sj| ≤ Sj, let mj ≤ γj ≤ Mj, with mj > 0, and choose with 0 < η < 1. The endpoint conditions for contraction in the induced norm are
where γ ∈ {mj,Mj},0 < ρj < 1.The inequalities in (22) use the positive-semidefinite matrix order. Since Φj is affine in γ and the induced matrix norm is convex, (22) bounds the induced norm by ρj throughout the sector. Let and suppose that and . The ellipsoid of radius rP,j lies within the sector because . The contraction and residual bounds preserve the radius under (21) by the triangle inequality. Iteration of (21) yields
The disturbance-estimation error is also bounded by (23) through the identity .
For the controller gains in Table III, the lower bounds are approximately 925.06 s−1 in the electrical channels and 992.10 s−1 in the speed channel. Both exceed the corresponding gains of 522.36 and 765.73 s−1. At a control period of 20 μs and with η = 0.15, the endpoint checks give conservative contraction factors of 0.9931 for each electrical channel and 0.9980 for the speed channel. The electrical sector is 402–5224 s−1 on |sd|,|sq| ≤ 2A, and the speed sector is 226–5598 s−1 on |sω| ≤ 2rad/s. The upper bounds follow from h(r) ≥ e−βr + αr. The minimum of the right-hand side is approximately 0.29753 for the selected parameters. Applying (23) to a switched trajectory also requires the stated initial-error and residual bounds. Section 5 evaluates the large-disturbance, loaded-start, and measurement-noise cases in simulation.
4.3. ACSMDO+FCS-MPCC
Discretizing (13) by forward Euler, with the injection specified in (17), gives the observer update in (24).
The update in (24) supplies the one-step state and disturbance estimates. The delay-compensated current predictor then advances to sample k + 2.
4.4. One-Step Delay Compensation Calculation Method
At sample k, the observer propagates the state with the voltage already applied to the inverter. The candidate voltages for the second step are transformed from the stationary frame to the synchronous frame using θe(k) + Tsωe(k), where θe is the electrical rotor angle. The two-step current prediction for each candidate is computed using its transformed voltage as follows:
The predicted speed in (25) determines the cross-coupling terms. The angle extrapolation determines the voltage transformation. The current reference is already expressed in synchronous coordinates and is held over the two-step horizon:
The speed loop updates at the next actual sample. The controller selects the candidate with the minimum cost:
In Figure 3, the reference, prediction, cost, and observer blocks correspond to (26), (25), (27), and (24), respectively. The selected state is stored for application at k + 1. The effect of each design element is evaluated in Section 5.4.
4.5. Computational Burden and Update Deadline
The ACSMDO is updated once per control period, and all eight candidate evaluations share its first-step estimates. The adaptive injection requires three scalar exponentials, three divisions, and three cubic terms per update.
With one-period actuation, the selected switching command must be ready before the next control update. A digital implementation at the 20 μs period used in the simulations must accommodate signal acquisition, controller execution, and command writing within this period, with allowance for timing variation. Section 5 evaluates sensitivity to deviations from the assumed actuation delay in simulation. Timing on the target platform remains to be measured.
5. Simulation Results
5.1. Simulation Setup and Comparison Methods
Four controllers were compared in MATLAB/Simulink under identical operating conditions using the same SPMSM and ideal two-level inverter. Table 1 specifies the motor parameters.
Table 1.
PMSM system parameters.
Plant integration used the midpoint method with a 5 μs step. The control period was 20 μs, and waveforms were recorded every 10 μs. All runs started with zero stator currents, electrical speed, rotor angle and observer estimates. The speed PI integrator was initialized to zero, and the inverter queue was initialized to the zero-voltage switching state. The shared speed PI used Kp = 0.17756A/(r/min) and Ki = 8.8782A/[(r/min)s], with conditional integration and a q-axis reference limit of ±30 A. The default actuation delay was one control period. The delay sensitivity tests varied the implemented delay independently of the compensation model.
The tests include a nominal case, six cases with one electrical parameter varied, and two cases with simultaneous changes. The specified multipliers are applied to the plant from startup, while each controller retains its nominal motor model. For these tests, the speed reference is 1500 r/min. Starting from 5 N·m, the load torque steps to 15 N·m at 0.4 s and to 10 N·m at 0.8 s. Each simulation runs for 1.2 s with noise-free measurements. Table 2 gives the multipliers for resistance, inductance, flux linkage, inertia, and damping, in that order.
Table 2.
Plant parameter multipliers in the main comparison.
Conventional FCS-MPCC used the nominal prediction model with one-period delay compensation. CSMDO-based FCS-MPCC used a fixed reaching law in the composite observer. The proposed ACSMDO-based FCS-MPCC used the adaptive reaching law. The quantized EV2-MPCC + ISMO adaptation used the published electrical ISMO reaching-law parameters and the twelve-sector extended voltage set from [55]. Its pulse count was quantized to one or two 10 μs subintervals in the shared control period. A one-subinterval pulse used the closest basic active vector and a zero state. A two-subinterval pulse used either the same basic vector twice or the two adjacent basic vectors of a virtual vector.
Only the ACSMDO gains were selected by searching 158 candidate settings over eight parameters. The baseline controllers retained fixed settings and were not subjected to this search. The objective was the mean joint current-tracking RMSE across four separate training cases. Their speed references were 1400, 1250, 1750 and 1825 r/min, respectively. The corresponding plant multipliers were (1, 1, 1, 1, 1), (0.72, 0.63, 0.91, 0.72, 1.10), (1.60, 1.58, 1.09, 1.42, 1.30) and (1.10, 0.95, 0.94, 1.08, 1.00), in the order of Table 2. The fourth case included current and electrical-speed noise with standard deviations of 0.065 A and 1.0 rad/s. Candidates had to satisfy the continuous gain conditions and the local sampled contraction conditions in Section 6. Mean THD and mean peak-to-peak ripple in each current axis could not exceed those of the starting setting on the training cases. The lowest-RMSE candidate that passed these constraints and completed the low-inductance, combined-mismatch and delay checks was selected. The gains of all controllers were then fixed throughout the reported tests. Table 3 reports the rounded values.
Table 3.
Observer gains used in the simulations.
The ACSMDO uses α = 0.335636 and β = 3.892866. The fixed reaching law used for the CSMDO-based baseline is k1jsj + k2jsgn(sj).
Tracking error was defined as the simulated current minus its reference. The current-tracking RMSE was computed from 0.2 to 1.2 s. Joint RMSE equals the square root of the sum of squared d- and q-axis RMSE values. Mean tracking error and peak-to-peak ripple were evaluated from 1.02 to 1.2 s. Phase-A current THD was calculated from harmonics 2–50 over complete electrical revolutions in the interval from 1.0 to 1.2 s, resampled at 512 uniformly spaced electrical-angle points per revolution. The reported switching frequency is the mean equivalent switching-cycle rate per inverter leg, calculated by dividing the total number of transitions of the three upper gates by six times the duration of the same interval. Speed settling after the first load change was evaluated using a ±1% band around the reference speed. The response had to remain inside the band through 0.6 s for a minimum of 20 ms.
5.2. Current Tracking Under Parameter Mismatch
Figure 4 and Figure 5 show the four controllers under increased combined mismatch and reduced inductance, respectively. Across the eight mismatch cases, the mean joint current RMSE was 1.745 A for ACSMDO-based FCS-MPCC, 2.443 A for conventional FCS-MPCC, 1.754 A for CSMDO-based FCS-MPCC, and 4.264 A for the quantized EV2-MPCC + ISMO adaptation. The reduction relative to conventional FCS-MPCC was 28.6%. Relative to CSMDO-based FCS-MPCC, the proposed controller reduced the eight-case mean by 0.49%, with lower joint RMSE in five of the eight cases. This small difference compares the searched ACSMDO setting with a fixed CSMDO setting and does not isolate the effect of the reaching law. Table 4 reports the two representative cases. The ISMO disturbance integrator gains cd = cq = 400 s−1 were retained from the SPMSM implementation because numerical values were unavailable in the reference. The published ISMO reaching-law settings were k1 = k2 = 2000, α = 0.3, β = 5 and δ = 0.3. Pulse quantization reduces the extended-vector resolution, and the disturbance-integrator gains were assigned for this adaptation. The switching frequencies in Table 4 are also higher for this implementation. These results characterize the tested adaptation and do not establish superiority over the original modulated method in [55].
Figure 4.
dq current tracking under increased combined parameter mismatch at 1500 r/min. (a) Conventional FCS-MPCC. (b) CSMDO-based FCS-MPCC. (c) ACSMDO-based FCS-MPCC. (d) EV2-MPCC + ISMO (quantized adaptation).
Figure 5.
dq current tracking at half the nominal inductance and 1500 r/min. (a) Conventional FCS-MPCC. (b) CSMDO-based FCS-MPCC. (c) ACSMDO-based FCS-MPCC. (d) EV2-MPCC + ISMO (quantized adaptation).
Table 4.
Current tracking in the two representative cases.
In the increased combined mismatch case, the proposed method produced peak-to-peak d- and q-axis ripple of 3.125 and 3.199 A, respectively. Its mean tracking errors were -0.038 and -0.020 A in the two axes. The speed entered and remained within the ±1% band after 30.00 ms. Table 5 summarizes these steady-state current measures and speed-settling times.
Table 5.
Steady-state and settling measures under increased combined mismatch.
In the low-inductance case, the proposed method reduced the joint RMSE from 5.175 to 3.074 A relative to conventional FCS-MPCC, while the phase-A THD increased from 4.099% to 8.885%. In the main comparison under increased combined mismatch, the THD was 2.844% for the proposed method and 2.893% for CSMDO-based FCS-MPCC.
5.3. Parameter Sensitivity and Disturbance Reconstruction
Table 6 quantifies the individual parameter effects on the proposed controller. The two-step prediction for the selected switching state was compared with the simulated current two control periods later on the same trajectory. Prediction RMSE was evaluated at control instants from 0.2 s wherever both samples were available. Each mismatch row changes only the indicated plant parameter.
Table 6.
Single-parameter sensitivity of two-step prediction.
Inductance mismatch produced the largest prediction deviations among the single-parameter cases. The changed voltage-to-current slope contributes an electrical disturbance that varies with the actual inverter state. Flux-linkage mismatch primarily affected the q-axis prediction in these simulations. The isolated inertia and damping variations had small effects on the two-step current prediction at the tested step size and operating point.
The simulated disturbance reference was calculated as the difference between the actual state derivative and the nominal observer drift, evaluated at the same state and applied voltage. Figure 6 shows the true and estimated disturbances with 2 ms window means, the min–max ranges of the true electrical disturbances, and the sampled q-axis values near the first load step. The observer primarily recovers the mean electrical disturbance over the 2 ms windows. The instantaneous switching component remains unresolved, as shown by the raw samples and large same-sample errors. Over the control samples from 0.2 to 1.2 s, the d- and q-axis same-sample reconstruction RMSE values were 49.26 and 52.96 kA/s for the ACSMDO and 49.83 and 52.82 kA/s for the CSMDO. The corresponding mechanical disturbance RMSE values were 402.3 and 415.2 rad/s2. The observers produced nearly equal electrical reconstruction errors, and the ACSMDO gave the lower mechanical reconstruction error in this case. Figure 7 summarizes the joint current-tracking RMSE and phase-A current THD for the nominal case and all eight mismatch cases. The proposed controller reduced the joint RMSE relative to conventional FCS-MPCC in all eight mismatch cases. The THD ranking depended on the operating point.
Figure 6.
Disturbance reconstruction under increased combined parameter mismatch. Panels (a–c) show 2 ms means for the electrical and mechanical disturbances. Panel (d) shows raw q-axis samples near the first load step, with the switching component unresolved.
Figure 7.
Current performance under nominal conditions and eight parameter-mismatch conditions. (a) Joint d- and q-axis tracking RMSE. (b) Phase-A current THD over harmonics 2–50.
5.4. Contribution of Each Design Element
Figure 8a shows that rotating the reference introduced a nonzero d-axis component of up to 0.669 A in the cost function under increased combined mismatch. Holding the synchronous dq reference removed this component and reduced the d-axis tracking RMSE from 0.662 to 0.544 A. In Figure 8b, the adaptive reaching law decreased the peak absolute q-axis tracking error from 4.297 to 2.307 A over the first 50 ms after the load step. The fixed-law variant used the same gain coefficients, and the joint RMSE changed from 0.813 to 0.770 A.
Figure 8.
Design ablations under increased combined parameter mismatch. (a) d-axis command used in the cost function with synchronous reference holding and reference rotation. (b) q-axis tracking error with adaptive and fixed reaching laws. (c) Joint tracking RMSE for five simulated actuation delays.
Under increased combined mismatch, the simulated actuation delay was set to 0, 10, 20, 30 or 40 μs. The two-step predictor remained configured for one control period. At a delay of one period, the two-step compensation reduced the joint RMSE from 1.454 to 0.770 A in the increased combined mismatch case. The compensated RMSE increased to 1.757 and 1.703 A at delays of 1.5 and 2 periods. In the low-inductance case at the nominal one-period delay, the joint RMSE was 9.800 A for the one-step variant and 3.074 A for the compensated method. These results characterize the sensitivity of the simulated controller to deviations in actuation timing. Figure 8c compares the two compensation settings across all five tested delays.
Using the predicted electrical speed and the sampled plant speed on the same nominal-parameter simulation trajectory, with a rotor inertia of 0.00277 kg·m2, gave d-axis prediction RMSE values of 0.01741 and 0.01742 A, respectively. The corresponding q-axis values were 0.01659 and 0.01658 A, respectively. The maximum relative change in electrical speed between consecutive control samples after 0.2 s was 0.0496%. The close agreement shows that the choice of speed input had little effect on the two-step prediction under this operating condition.
5.5. Changes in Speed and Measurement Noise
Figure 9 compares the controllers at 750 and 2250 r/min, under two synthetic measurement-noise levels, and under a moderate combined parameter variation. The speed and noise tests used the increased combined mismatch set. The noise levels were defined by current and electrical-speed standard deviations of 0.05 A and 0.8 rad/s, and 0.10 A and 1.6 rad/s, respectively. The moderate case used plant multipliers of 1.25, 0.85, 0.90, 1.15, and 1.00 in the order given in Section 5.1. The same two load changes were applied in all cases. Zero-mean uniform noise was added to the sampled currents and electrical speed at each control update. Each method used the same generator seed (71537).
Figure 9.
Simulated robustness under two speeds, two synthetic measurement-noise levels, and moderate parameter mismatch. (a) Joint current RMSE. (b) Speed RMSE.
The wider parameter sweep was used as a stress test. The combined variations and noise levels are specified simulation settings.
At 750 and 2250 r/min, the joint RMSE of the proposed method was 0.801 and 0.836 A, compared with 1.151 and 1.808 A for conventional FCS-MPCC. The proposed method produced 1.082 A of joint RMSE at the higher noise level, compared with 1.704 A for conventional FCS-MPCC, 1.092 A for CSMDO-based FCS-MPCC and 2.730 A for the quantized EV2-MPCC + ISMO adaptation. The corresponding speed RMSE of the proposed method was 6.83 r/min. In the moderate mismatch case, the joint current RMSE was 1.823 A for the proposed method and 1.834 A for CSMDO-based FCS-MPCC, while their phase-A THD values were 4.948% and 4.813%.
6. Conclusions
The proposed FCS-MPCC combines a two-step predictor with an ACSMDO for an SPMSM drive with a one-period actuation delay. The observer supplies the first-step estimates of current, electrical angular velocity, and lumped disturbances. Using the predicted electrical speed in the second step yielded nearly the same current-prediction RMSE as using the sampled plant speed on the same simulation trajectory.
An adaptive sliding mode approach law is employed in the ACSMDO to vary the switching injection with the observer error. Under increased combined mismatch, the adaptive law decreased the peak q-axis tracking error after the first load step from 4.297 to 2.307 A in the matched-gain comparison. With the synchronous current reference held in both variants, two-step delay compensation reduced the joint RMSE from 1.454 to 0.770 A at a one-period actuation delay. The validation was conducted in MATLAB/Simulink. Across eight parameter-mismatch cases, the mean joint RMSE was 28.6% lower relative to conventional FCS-MPCC and 0.49% lower relative to the fixed-gain CSMDO baseline. Only ACSMDO was subjected to the gain search. Under low inductance, the proposed controller had lower joint RMSE and higher phase-current THD than conventional FCS-MPCC. Future work will implement the controller on a digital control platform and evaluate current tracking and disturbance rejection on an SPMSM test bench under load steps and controlled parameter mismatch. Timing measurements will cover signal acquisition, worst-case controller execution, and command writing to assess whether the complete update meets the 20 μs control deadline.
Author Contributions
Supervision, F.L.; writing—original draft preparation, H.S.; writing—review and editing, F.L. and H.S. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the “Unmanned” Intelligent Equipment and Technology Popularization and Application Project for Main Production Links of Rice-Wheat Rotation, grant number NJ2021-59.
Data Availability Statement
The raw simulation data underlying the results of this study are available from the authors on request.
Conflicts of Interest
The authors declare no conflict of interest.
References
- Li, T.; Sun, X.D.; Lei, G.; Yang, Z.B.; Guo, Y.G.; Zhu, J.G. Finite-control-set model predictive control of permanent magnet synchronous motor drive systems—An overview. IEEE/CAA J. Autom. Sin. 2022, 9, 2087–2105. [Google Scholar] [CrossRef] [Scilit]
- Shi, Z.; Sun, X.; Yang, Z.; Cai, Y.; Lei, G.; Zhu, J.; Lee, C.H.T. Design optimization of a spoke type axial-flux PM machine for in-wheel drive operation. IEEE Trans. Transp. Electrif. 2024, 10, 3770–3781. [Google Scholar] [CrossRef] [Scilit]
- Shi, Z.; Sun, X.; Cai, Y.; Yang, Z. Robust design optimization of a five-phase PM hub motor for fault-tolerant operation based on taguchi method. IEEE Trans. Energy Convers. 2020, 35, 2036–2044. [Google Scholar] [CrossRef] [Scilit]
- Mastanaiah, A.; Ramesh, T.; Isradani, T.; Bonthagorla, P.K. A unified computationally efficient model predictive control for multilevel inverter–fed multiphase PMSM drives for electric vehicles. IEEE Open J. Veh. Technol. 2026, 7, 1021–1035. [Google Scholar] [CrossRef] [Scilit]
- Sambhavi, Y.V.; Vijayapriya, R. Modified field-oriented control scheme for a 5-level knight inverter in PMSM-based electric vehicle applications. IEEE Access 2025, 13, 199846–199863. [Google Scholar] [CrossRef] [Scilit]
- Carmona, F.P.; Rivas, J.J.R.; Garduño, D.M.; González, R.O.; Castillo, O.C. Comparative analysis of PI and LQR control for PMSM in electric traction system. IEEE Access 2025, 13, 198991–199005. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Y.; Zhu, J. A novel duty cycle control strategy to reduce both torque and flux ripples for DTC of permanent magnet synchronous motor drives with switching frequency reduction. IEEE Trans. Power Electron. 2011, 26, 3055–3067. [Google Scholar] [CrossRef] [Scilit]
- Li, S.; Gu, H. Fuzzy adaptive internal model control schemes for PMSM speed-regulation system. IEEE Trans. Ind. Informat. 2012, 8, 767–779. [Google Scholar] [CrossRef]
- Liu, G.; Chen, L.; Zhao, W.; Jiang, Y.; Qu, L. Internal model control of permanent magnet synchronous motor using support vector machine generalized inverse. IEEE Trans. Ind. Informat. 2013, 9, 890–898. [Google Scholar] [CrossRef] [Scilit]
- Wang, Y.; Feng, Y.; Zhang, X.; Liang, J. A new reaching law for antidisturbance sliding-mode control of PMSM speed regulation system. IEEE Trans. Power Electron. 2020, 35, 4117–4126. [Google Scholar] [CrossRef] [Scilit]
- Junejo, A.K.; Xu, W.; Mu, C.; Ismail, M.M.; Liu, Y. Adaptive speed control of PMSM drive system based a new sliding-mode reaching law. IEEE Trans. Power Electron. 2020, 35, 12110–12121. [Google Scholar] [CrossRef] [Scilit]
- Wu, M.; Sun, X.; Zhu, J.; Lei, G.; Guo, Y. Improved model predictive torque control for PMSM drives based on duty cycle optimization. IEEE Trans. Magn. 2021, 57, 8200505. [Google Scholar] [CrossRef] [Scilit]
- Tu, W.; Luo, G.; Chen, Z.; Cui, L.; Kennel, R. Predictive cascaded speed and current control for PMSM drives with multi-timescale optimization. IEEE Trans. Power Electron. 2019, 34, 11046–11061. [Google Scholar] [CrossRef] [Scilit]
- Rahman, T.U.; Ullah, A.; Ullah, S.; Pan, J.; Alghamdi, B.; Rehman, A.; Ouyang, Z. Fast smooth super-twisting SMC and super-twisting disturbance estimation for PMSM speed control. IEEE Trans. Consum. Electron. 2025, 71, 10161–10171. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Y.; Xu, D.; Liu, J.; Gao, S.; Xu, W. Performance improvement of model-predictive current control of permanent magnet synchronous motor drives. IEEE Trans. Ind. Appl. 2017, 53, 3683–3695. [Google Scholar] [CrossRef] [Scilit]
- Gong, C.; Hu, Y.; Ma, M.; Gao, J.; Shen, K. Novel analytical weighting factor tuning strategy based on state normalization and variable sensitivity balance for PMSM FCS-MPTC. IEEE/ASME Trans. Mechatron. 2020, 25, 1690–1694. [Google Scholar] [CrossRef] [Scilit]
- Xie, W.; Wang, X.; Wang, F.; Xu, W.; Kennel, R.; Gerling, D. Dynamic loss minimization of finite control set-model predictive torque control for electric drive system. IEEE Trans. Power Electron. 2016, 31, 849–860. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Zhang, Y.; Lei, G.; Guo, Y.; Zhu, J. An improved deadbeat predictive stator flux control with reduced-order disturbance observer for in-wheel PMSMs. IEEE/ASME Trans. Mechatron. 2022, 27, 690–700. [Google Scholar] [CrossRef] [Scilit]
- Hanke, S.; Wallscheid, O.; Bocker, J. Continuous-control-set model predictive control with integrated modulator in permanent magnet synchronous motor applications. In Proceedings of the 2019 IEEE International Electric Machines & Drives Conference (IEMDC), San Diego, CA, USA, 12–15 May 2019; IEEE: Piscataway, NJ, USA, 2019; pp. 2210–2216. [Google Scholar]
- Sun, X.; Lin, X.; Han, S.; Wang, Y. An improved continuous-control-set model predictive control for dual three-phase PMSMs based on extended state observer. IEEE Trans. Ind. Electron. 2025, 72, 3449–3459. [Google Scholar] [CrossRef] [Scilit]
- Su, Z.; Sun, X.; Lei, G.; Yao, M.; Zhang, L. Augmented continuous-control-set model predictive current control for dual three-phase PMSM drives. IEEE/ASME Trans. Mechatron. 2025, 30, 2367–2378. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Lin, X.; Guo, D.; Lei, G.; Yao, M. Improved deadbeat predictive current control with extended state observer for dual three-phase PMSMs. IEEE Trans. Power Electron. 2024, 39, 6769–6782. [Google Scholar] [CrossRef] [Scilit]
- Lim, C.S.; Lee, S.S.; Levi, E. Continuous-Control-Set Model Predictive Current Control of Asymmetrical Six- Phase Drives Considering System Nonidealities. IEEE Trans. Ind. Electron. 2023, 70, 7615–7626. [Google Scholar] [CrossRef] [Scilit]
- Navarro-Temoche, A.; Jugo, J.; Ibarra, E.; Kortabarria, I.; Matallana, A. Fault tolerant CCS-MPC for asymmetrical DTP-PMSM drives assisted by fault detection algorithm. IEEE Access 2025, 13, 165263–165275. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Li, T.; Yao, M.; Lei, G.; Guo, Y.; Zhu, J. Improved finite-control-set model predictive control with virtual vectors for PMSHM drives. IEEE Trans. Energy Convers. 2021, 37, 1885–1894. [Google Scholar] [CrossRef] [Scilit]
- Li, T.; Sun, X.; Yang, Z.; Lei, G. Simplified two-step model predictive control with fast voltage vector search. IEEE Trans. Ind. Electron. 2025, 72, 3303–3312. [Google Scholar] [CrossRef] [Scilit]
- Yeganeh, M.S.O.; Oshnoei, A.; Mijatovic, N. Online learning-based multistep predictive control for PMSM drives with a small DC-link capacitor. IEEE Trans. Ind. Electron. 2026, 73, 3649–3661. [Google Scholar] [CrossRef] [Scilit]
- Cortés, P.; Rodríguez, J.; Silva, C.; Flores, A. Delay compensation in model predictive current control of a three-phase inverter. IEEE Trans. Ind. Electron. 2012, 59, 1323–1325. [Google Scholar] [CrossRef] [Scilit]
- Zhang, X.; Zhang, L.; Zhang, Y. Model predictive current control for PMSM drives with parameter robustness improvement. IEEE Trans. Power Electron. 2019, 34, 1645–1657. [Google Scholar] [CrossRef] [Scilit]
- Li, T.; Sun, X. Improved model predictive robust current control for permanent magnet synchronous hub motor. In Proceedings of the 2021 IEEE International Conference on Predictive Control of Electrical Drives and Power Electronics (PRECEDE), Jinan, China, 20–22 November 2021; IEEE: Piscataway, NJ, USA, 2021; pp. 147–151. [Google Scholar]
- Sun, X.; Zhang, S.; An, X.; Su, Z.; Li, F. A robust DPCC and inductance identification method for SPMSM based on incremental model and current error compensation. IEEE Trans. Ind. Electron. 2026, 73, 219–229. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Zhang, S.; Yang, Z.; Lei, G.; Li, T. Improved DPCC and parameter identification for permanent magnet synchronous motors with current error compensation. IEEE Trans. Ind. Electron. 2025, 72, 9911–9921. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Su, Z.; Lei, G.; Yao, M. Robust predictive cascaded speed and current control for PMSM drives considering parameter variations. IEEE Trans. Ind. Electron. 2024, 71, 10235–10245. [Google Scholar] [CrossRef] [Scilit]
- Bui, M.X.; Nguyen, H.-N.; Nutkani, I.; Fernando, N.; Dutta, R.; Rahman, M.F. Reinforcement learning-based online estimation of the inductances of the permanent magnet synchronous machines. IEEE Trans. Instrum. Meas. 2025, 74, 3003212. [Google Scholar] [CrossRef] [Scilit]
- Beltrán-Pulido, A.; Aliprantis, D.; Bilionis, I.; Munoz, A.R.; Chase, N. Physics-informed neural networks for parametric modeling of permanent magnet synchronous machines. IEEE Trans. Energy Convers. 2026, 41, 648–661. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Y.; Jin, J.; Huang, L. Model-free predictive current control of PMSM drives based on extended state observer using ultralocal model. IEEE Trans. Ind. Electron. 2021, 68, 993–1003. [Google Scholar] [CrossRef] [Scilit]
- Kapita, K.; Sun, X.; Xu, H.; Li, T.; Lei, G. Adaptive Model-free predictive current control of SPMSM using cascade extended state observers for enhanced disturbance rejection. IEEE Trans. Ind. Electron. 2026, 73, 12752–12762. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Huang, Z.; Yang, Z.; Lei, G.; Li, T. Improved model-free predictive current control for suppressing inverter nonlinearity and parametric time-varying of PMSM drive systems. IEEE Trans. Ind. Electron. 2025, 72, 9866–9875. [Google Scholar] [CrossRef] [Scilit]
- Li, T.; Sun, X.; Su, Z.; Zha, X.; Dianov, A.; Prakht, V.; Demidova, G.; Ma, J. Model-free predictive control for harmonic suppression of PMSMs based on adaptive resonant controller. IEEE Trans. Energy Convers. 2025, 40, 3104–3114. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Shen, Z.; Huang, Z.; Su, Z.; Li, F. Finite-time gradient method based adaptive model-free predictive current control with harmonic suppression. IEEE Trans. Ind. Electron. 2026, 73, 9751–9761. [Google Scholar] [CrossRef] [Scilit]
- Mousavi, M.S.; Davari, S.A.; Zolfagharian, R.; Garcia, C.; Flores-Bahamonde, F.; Wang, F. Gradient descent algorithm based on extended state observer for loss minimization of ultralocal model predictive controlled PMSM drives. IEEE Trans. Transp. Electrif. 2026, 12, 1198–1208. [Google Scholar] [CrossRef] [Scilit]
- Su, Z.; Sun, X.; Lei, G.; Yao, M. Improved model-free predictive current control for SPMSM drives with adaptive prediction horizon strategy. IEEE Trans. Ind. Electron. 2025, 72, 5705–5715. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Su, Z.; Lei, G.; Cai, Y.; Yao, M. Adaptive model-free predictive current control for SPMSM drives with optimal virtual vector modulation. IEEE/ASME Trans. Mechatron. 2024, 29, 2569–2578. [Google Scholar] [CrossRef] [Scilit]
- Agoro, S.; Husain, I. Model-Free Predictive Current and Disturbance Rejection Control of Dual Three-Phase PMSM Drives Using Optimal Virtual Vector Modulation. IEEE J. Emerg. Sel. Top. Power Electron. 2023, 11, 1432–1443. [Google Scholar] [CrossRef] [Scilit]
- Su, Z.; Sun, X.; Lei, G.; Yao, M. Model-free predictive current control for dual three-phase PMSM drives with an optimal modulation pattern. IEEE Trans. Ind. Electron. 2024, 71, 10140–10149. [Google Scholar] [CrossRef] [Scilit]
- Su, Z.; Sun, X.; Ortombina, L.; Bianchi, N. Model-Free predictive current control with virtual harmonic back-EMF identification for dual three-phase PMSM drives. IEEE Trans. Ind. Electron. 2026, 73, 8379–8391. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Lin, X.; Zhang, L.; Yao, M.; Cai, Y. An improved torque enhancement strategy for dual three-phase PMSM based on model-free predictive current control. IEEE Trans. Transp. Electrif. 2025, 11, 176–187. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Zhang, H.; Lin, X.; Su, Z.; Yao, M. Speed sensorless control based on model -free predictive controller for dual three-phase PMSMs. IEEE Trans. Ind. Electron. 2025, 72, 11110–11119. [Google Scholar] [CrossRef] [Scilit]
- Davari, S.A.; Mousavi, M.S.; Nikmaram, B.; Flores-Bahamonde, F.; Wang, F.; Wheeler, P. Sensorless model-free predictive control of permanent magnet synchronous motor. IEEE Trans. Ind. Electron. 2026, 73, 1571–1581. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Li, T.; Zhu, Z.; Lei, G.; Guo, Y.; Zhu, J. Speed sensorless model predictive current control based on finite position set for PMSHM drives. IEEE Trans. Transp. Electrif. 2021, 7, 2743–2752. [Google Scholar] [CrossRef] [Scilit]
- Sarajian, A.; Guan, Q.-X.; Harbi, I.; Khaburi, D.A.; Kennel, R.; Flores-Bahamonde, F.; Rodríguez, J. Efficient current sensorless model predictive control for matrix converter-fed PMSM drives. IEEE Trans. Ind. Electron. 2025, 72, 12504–12515. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Cao, J.; Lei, G.; Guo, Y.; Zhu, J. A robust deadbeat predictive controller with delay compensation based on composite sliding-mode observer for PMSMs. IEEE Trans. Power Electron. 2021, 36, 10742–10752. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Zhang, Y.; Cai, Y.; Tian, X. Compensated deadbeat predictive current control considering disturbance and VSI nonlinearity for in-wheel PMSMs. IEEE/ASME Trans. Mechatron. 2022, 27, 3536–3547. [Google Scholar] [CrossRef] [Scilit]
- Sun, X.; Liu, Y.; Su, Z.; Lei, G.; Zhu, J. Robust DPCC for dual three-phase pmsms based on moving horizon estimator with harmonic suppression. IEEE Trans. Ind. Electron. 2025, 73, 8197–8207. [Google Scholar] [CrossRef] [Scilit]
- Li, T.; Sun, X.; Yao, M.; Guo, D.; Sun, Y. Improved finite control set model predictive current control for permanent magnet synchronous motor with sliding mode observer. IEEE Trans. Transp. Electrif. 2024, 10, 699–710. [Google Scholar] [CrossRef] [Scilit]
- Wang, J.; Liu, Y.; Yang, J.; Wang, F.; Rodríguez, J. Adaptive integral extended state observer-based improved multistep FCS-MPCC for PMSM. IEEE Trans. Power Electron. 2023, 38, 11260–11276. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |