Abstract
In line with the International Marine Organisation (IMO) Net Zero 2050 strategy and its emphasis on improving shipboard energy efficiency, this project conducts a system analysis of a marine ICE exhaust gas, waste heat recovery system using ORC technology to quantify exergy efficiency and SFOC at varied ICE loads. A Wärtsilä 6L25 2 MW marine ICE in the diesel generation configuration is used for the case study and a commercial ORC system, selected based on calculated engine exhaust gas thermal energy. A high temperature heat exchanger design is calculated from first principles using the analytical NTU method, to give base geometry requirements to assess feasibility. Finally, exergy efficiency and combined ORC-DG system SFOC is quantified. Key results indicated exergy efficiency ranges from to , with highest exergy efficiency being at 50% ICE load and lowest at 100% ICE load. Combined SFOC was shown to be lowest at 85% ICE load, representing a reduction from DG SFOC. The analysis indicated a usable ORC power output, ranging from to . The main conclusions drawn are that research and ORC systems suitable for ICEs similar to the Wärtsilä 6L25 2 MW in the DG configuration are underreported, partially owing to a lack of suitable real-world data for research. Exergy efficiency and combined SFOC support the presented ORC-DG waste heat recovery system as an effective way to utilise exhaust gas waste heat that would otherwise be lost. However, when selecting and optimising an ORC system for waste heat recovery, designers should consider both real vessel operational profiles and lowest DG SFOC to maximise exergy recovery and efficiency with a high degree of accuracy. Similarly, optimising heat exchangers for actual DG operational profiles rather than theoretical 100% would avoid underutilisation and a larger physical heat exchanger footprint than necessary. This research should be considered as a first step system analysis of exhaust gas, waste heat recovery systems using ORC, as well as a contribution to critical research surrounding emissions reductions from shipping. Future studies should validate and expand upon the study by software modelling utilising full operational data from a suitable case study of vessels and manufacturers’ equipment data.
1. Introduction
The project aligns with the global maritime industries’ efforts to reduce greenhouse gas (GHG) emissions. To address the challenges of climate change, the International Maritime Organisation (IMO) has set an ambitious strategy to combat the international maritime sector’s contributions to global GHG emissions. As the IMO is a UN organisation, the UN sustainable development goals [1] are core drivers of the strategy. The strategy aims for net zero GHG emissions by or around 2050 and striving for GHG emissions reductions of 30% by 2030 and 80% by 2040 compared to 2008 levels [2]. The Fourth IMO GHG Study in 2020 indicated that in 2018, shipping accounted for 2.89% of global anthropogenic GHG emissions. By 2050, the study estimates a 90–130% increase in GHG emissions from 2008 levels [3]. Unless rapid change is forthcoming, the IMO strategy will potentially fail to deliver. Regionally, countries including the UK and Norway are looking to domestic fleets to lead maritime decarbonisation [4,5]. Both nations have substantial fleets operating in the offshore and short sea sector. The UK has identified the offshore wind sector to act as a potential “springboard” to decarbonise the maritime industry, with a focus on service operations vessels (SOV) and other offshore support vessels (OSV) [6].
Ship owners already face a volatile environment from fossil fuel price fluctuations, rapid regulatory changes and uncertainty about what GHG reduction measures to adopt. Long-term decarbonisation will heavily rely on zero-carbon and alternative fuels. In the short term, improving the energy efficiency of ships’ systems is an effective decarbonisation strategy. Energy efficiency can improve specific fuel oil consumption (SFOC); the fuel flow rate per unit of power output [7] and recover exergy; the maximum theoretical work obtainable [8] from a system. The global classification society DNV reports that improving energy efficiency and therefore SFOC can lead to a direct reduction in emissions, saving fuel and helping ship owners comply with regulations [9].
Energy efficiency improvement measures range from hull coatings to optimised propellers, wind assistance, and WHR [10] Marine diesel power plants are only able to utilise around 50% of supplied total fuel energy to do work [10,11] and the remainder is lost to the atmosphere, primarily contained as thermal energy in the exhaust gas (EG). WHR recovery in the form of ICE exhaust gas boilers for steam production is a mature maritime technology familiar to ship owners [12]. A review of maritime WHR technology by Singh and Pedersen [11] explored numerous WHR sources and technologies, concluding that engine EG offered the highest WHR potential from a heat quality and quantity perspective. Approximately 26% of the fuel energy is lost as heat in the EG [13]. WHR functions by utilising the potential exergy of the exhaust gas to do actual useful work instead of it being lost to the atmosphere, therefore improving the whole system exergy efficiency.
Of the WHR technologies available, Rankine Cycle (RC) and its variations, Kalina Cycles (KC), EG turbines and thermo-electric generators and the Organic RC (ORC) have gained much attention. ORC offers effective efficiency recovery values [11]. ORC can use low to high grade heat sources, all of which comprise the majority of WH sources onboard ships. ORC system research has primarily focused on industrial applications; however, maritime research remains underrepresented [13].
ORC WHR systems studies agree that ORC has potential as an effective way to improve energy efficiency, lower SFOC, recover exergy and reduce CO2 emissions. Additionally, many vessels must comply with MARPOL, Annex IV, Regulation 13 Tier III NOx emissions requirements [14] and must have exhaust aftertreatment, typically a Selective Catalytic Reactor (SCR). It is important to factor in an SCR when considering a WHR system.
This project will broadly address the gaps in research and take the practical challenges faced by ship owners into account. The project will expand upon the research conducted on diesel electricity powered by four-stroke ICE in the DG configuration. A commercial ORC system integrated with EG WHR of a marine ICE, typical of those installed on SOVs and OSVs operating in the UK and Norwegian offshore sectors, will be investigated. The project aims to quantify the effects on exergy efficiency and power generation SFOC of a Wärtsilä 6L25 2 MW DG [15] with SCR aftertreatment at varied load points when incorporating a commercially available exhaust gas WHR ORC system. The focus on commercially available systems will attempt to reduce the knowledge gap between theoretical study and practical implementation, highlighting potential routes to speed up adoption of the technology.
As with any installation onboard ship, design approval and certification by the shipowners’ selected classification society, for example DNV, is required for new builds and refits. Design approval and certification must be in line with class society rules and regulations, which themselves follow the IACS unified requirements [16] and interpretations [17] of IMO conventions, in particular SOLAS [18]. Installations not covered by existing rules will follow SOLAS Chapter II-1, Regulation 55, Alternative design and arrangements [19].
Shipowners require much needed clarity on feasible GHG emissions reduction solutions to make informed decarbonisation strategy decisions.
2. Literature Review
Research generally covers ICE waste heat from either EG or combined EG and ancillary systems such as jacket water (JW) heat recovery. Song, Song and Gu [20] conducted a thermodynamic and performance optimisation analysis of a dual ORC system to recover heat from EG and JW of a 996 kW marine four-stroke ICE, finding a total net power output of 101 kW from the combined ORC, which correlates to a 10.2% increase in power compared to the baseline ICE power output. Zhang et al. [21] carried out a thermodynamic and economic study using a combined ORC and KC for WHR of two common marine two-stroke ICEs. The results indicated that the combined cycle can deliver power up to 25% of the respective ICE power rating with a system payback period of 8.1 to 8.5 years when R123 is utilised as the ORC and KC working fluid. Sabir, De and Modal [22] studied WHR from EG and JW of a 68,640 kW marine two-stroke ICE using three multi-pressure trans-critical regenerative ORCs to reduce vessel emissions. Their study concluded fuel savings of between 8.5% and 9.48%, resulting in reduced emissions of 13,000 t to 14,000 t annually.
Lebedevas and Čepaitis [23] conducted a numerical investigation of a Freon R134a ORC system using both high and low temperature WH from a Wärtsilä 12V46F four-stroke ICE. They reported that across the engine load range of 25% to 100%, energy efficiency increased by 13.5% to 21%. The researchers noted the individual waste heat sources energy efficiency ranged from 3% to 8%, highlighting the potential benefits of utilising combined WHR sources. Based on the engine type approval cycles, average energy efficiency with the ORC ranged from 8–15% compared to 3–6.5%.
In the context of WHR from EG only, much research effort is towards WHR covering optimal ORC component and system design and working fluids selection by thermo-economic, techno-economic, energy efficiency and exergy analysis. Understandably, many studies cover marine two-stroke ICE due to the bulk source of the global fleets’ GHG emissions being from container, bulk carriers and tanker vessels propelled by two-stroke [3]. Four-stroke marine ICE studies have slightly lower representation, reflecting the need to assess ORC applications for WHR from both engine types.
Lyu et al. [24] carried out an analysis of exergy, energy and environmental impact of ORC WHR fitted to a two-stroke ICE-propelled container vessel. Using voyage cycle data and assessing three working fluids, the highest net ORC system power was 605.75 kW at 90% engine load using cyclohexane. Exergy flow losses from within the ORC system at 80% engine load using cyclohexane were evaporator—159.8 kW, condenser—94 kW, expander—91 kW and pump—1.7 kW. The exergy results indicated the importance of optimising all components, particularly the evaporator. Total emissions over the voyage cycle of the combined ICE and ORC WHR equalled 60.99 t for toluene, 96.32 t for benzene and 99.68 t for cyclohexane. The results indicated that the working fluid capable of the highest net power output is not necessarily the most environmentally sound.
Shu et al. [25] conducted a thermal-economic analysis of an ORC system based on operational data of a cruise vessel over a 4-week period. The vessel is installed with four 5.85 MW Wärtsilä 6L45B four-stroke ICEs for main propulsion and four 2.76 MW Wärtsilä 6L32 DG providing electrical power. The study set a range of conditions based on the operational profile and assessed multiple working fluids. The results indicated that R123 was suitable for higher engine loads, comparable to a container ship profile, and R365mc was suitable for lower engine load profiles, comparable to tankers and bulk carriers. Nominally, all the working fluids assessed, except RC318, could meet a 5-year ORC system payback period.
Novelty has been introduced by expanding case studies to four-stroke ICE diesel electric vessels, which are prevalent in the offshore and short sea sector. Improving energy efficiency via electrification using hybrid battery and diesel electric systems is increasing [13]. Diesel electric systems produce power for both propulsion and auxiliary systems via common four-stroke diesel generators (DG). Ng, Tam and Wu [26] presented a techno-economic performance case study of ORC WHR using a diesel electric OSV powered by four Wärtsilä 6L26 1.95 MW DGs. The study investigated ORC thermodynamic performance by evaluating five working fluids at vessel operational load points and system economic assessment. The study reports a net ORC output of 160 kW and a thermal efficiency of 17–20% using cyclopentane and methanol working fluids. An annual fuel saving of 5–9% was shown for 75% and 85% load points. A simple methanol ORC was shown as having the shortest payback period. The study provides real-world operational data indicating indicative ICE load points and times in each mode, as shown in Figure 1 and Table 1.
Figure 1.
OSV load data as per operational mode graph [26].
Table 1.
OSV load data as per operational mode [26].
Sánchez-Lazano et al. [13] conducted techno-economic research into an ORC WHR unit using a diesel electric shuttle tanker powered by four Wärtsilä 12V46DF 14.4 MW DGs as the case vessel. The study vessel used a DC diesel electric architecture, differing from Ng, Tam and Wu’s [26] research that was based on an AC diesel electric vessel architecture. DC diesel electric is gaining momentum due to the system’s benefits over AC in terms of flexibility and simplicity, mitigating AC pitfalls including synchronous running of generators, reactive power management and large consumer current control transformer units [27]. The study concluded that at 85% DG load, the ORC system demonstrated a net electrical efficiency of 8.45%, a thermodynamic cycle efficiency of 18.73%, an estimated 18.59% reduction in fuel consumption and therefore reduced emissions compared to conventional systems. Finally, a payback period of 11.7 years was estimated for the ORC system.
The literature acknowledged the need for ORC system studies based on real operational data and the need to assess the economic implications of ORC WHR. Operational profiles vary significantly based on ship type and routing, complicating ORC feasibility based on only a small number of case studies. It is particularly apparent that gaps appear in the research addressing WHR from offshore vessels powered by lower power output four-stroke ICE. Real-world operational data for OSV is limited in the literature. Results of working fluid selection show a large variance, indicating that no single working fluid is universally suitable for all ORC systems. A balance of thermal efficiency, exergy change and environmental impact is likely required when selecting working fluids.
Commercial ORC systems in maritime are not widespread; to identify options, an inventory of available ORC systems suitable for maritime use is presented in Table 2. ORC systems are categorised by power output, thermal energy absorption requirements and hot water input range. All the ORC systems identified require a hot water intermediate loop to transfer thermal energy from exhaust gas to the ORC unit. It is noted that research predominantly favours using ICE exhaust gas directly as the heating medium for ORC evaporators, With the exception being the research conducted by Sánchez-Lazano et al. [22], in which an intermediate heat transfer loop was utilised. An intermediate heat transfer loop adds flexibility to OCR system installation and minimises the risk of chemical instability and overheating of the ORC [13].
Table 2.
Commercial ORC inventory.
The increase of NOx Tier III compliance requirements under Regulation 13 of MARPOL Annex VI [14] adds an additional layer consideration. Many vessels, including newbuilds operating in the UK and Norwegian offshore sectors, are fitted with SCR systems in the exhaust line. SCR systems’ effect on EG WHR has not been addressed in the literature.
The literature demonstrates significant potential for ORC systems to recover waste heat from marine ICEs, with previous studies reporting improvements in electrical output, thermal efficiency, fuel consumption and emissions. However, several limitations remain within the existing research. Firstly, the literature is weighted towards large marine two-stroke engines, particularly those used in container ships, tankers and bulk carriers, while comparatively less attention has been given to lower-power four-stroke engines used in offshore and short-sea applications. This limits the extent to which existing findings can be directly applied to the operational characteristics and waste-heat availability of these vessels.
Secondly, although some studies have incorporated real operational data, the literature indicates that vessel load profiles vary considerably according to vessel type, routing and operational mode. Consequently, conclusions based on a limited number of case studies may not be representative of the wider offshore vessel sector. The existing studies also demonstrate substantial variation in the most suitable ORC working fluid, suggesting that selection cannot be based solely on maximum power output or thermal efficiency. A more comprehensive assessment must consider the trade-offs between thermal performance, exergy behaviour and environmental impact.
A further limitation is the relatively limited consideration of practical integration issues associated with marine ORC systems. The literature predominantly considers direct use of engine exhaust gas as the ORC heating medium, whereas an intermediate heat-transfer loop can provide greater installation flexibility and reduce the risks associated with chemical instability and ORC working-fluid overheating. In addition, the increasing application of selective catalytic reduction (SCR) systems to meet IMO MARPOL Annex VI Tier III NOx requirements introduces an important interaction between exhaust-gas treatment and waste-heat recovery that has not been addressed in the reviewed literature. The present study addresses these gaps by focusing on waste-heat recovery from a four-stroke diesel-electric marine application, thereby extending the existing research beyond the predominantly studied large two-stroke propulsion engines. This is particularly relevant to offshore vessels, where diesel-electric architectures and hybridisation are becoming increasingly important. Previous work has demonstrated the value of using real operational load data for assessing ORC feasibility, but the relatively limited availability of such data for offshore vessels remains a recognised research gap.
The unique contribution of this work is therefore its application of ORC waste-heat recovery analysis to a lower-power four-stroke diesel-electric marine system while considering the vessel’s operational characteristics and the practical constraints associated with marine integration. In particular, the study contributes to the under-represented area of offshore/short-sea four-stroke ICE waste-heat recovery and provides a more application-specific assessment of ORC feasibility than studies based primarily on large two-stroke engines or idealised operating conditions. Furthermore, consideration of the interaction between exhaust-gas waste-heat recovery and SCR-equipped engines provides an additional practical dimension that is absent from the reviewed literature. The work consequently helps bridge the gap between demonstrating the theoretical thermodynamic potential of ORC systems and evaluating their suitability for realistic marine applications.
3. Methodologies and Methods
The approach and research methodology schematic for this project, created using Mind View, is shown in the Figure 2.
Figure 2.
Research methodology.
A schematic of the study ORC WHR equipment layout and components is presented in Figure 3. Following the layout, the ICE mechanically drives (orange arrow) a three-phase electrical alternator, which in turn supplies (green arrow) electrical power to the vessel switchboard. The vessel switchboard supplies (yellow arrow) electrical power to the propulsion azimuth thruster and the rest of the vessel. Exhaust (grey arrows) exits the ICE to the atmosphere via an SCR and the HTHX with integrated bypass. EG waste heat is transferred to the ORC unit via an intermediate circuit (blue arrows) with a circulating feed pump. Finally, the waste heat is utilised in the ORC unit to provide electrical power to the vessel switchboard.
Figure 3.
ORC WHR equipment layout [38,39,40,41,42,43,44].
3.1. Case Study ICE Data
Wärtsilä produces a medium-speed, four-stroke ICE for maritime and energy industry use. As a case study ICE, the Wärtsilä 6L25 2 MW marine DG was selected. Wärtsilä engines have been widely reported in literature, and the 6L25 2 MW is comparable in power output to the case vessel OSV studied by Ng, Tam and Wu [26].
Table 3 lists the technical specifications of the Wärtsilä 6L25 2 MW. The engine runs on light fuel oil (LFO), referring to the distillate fuel grades listed in ISO 8217:2024 [45]. Ultra-low sulphur marine gas oil (ULSMGO) is selected as the LFO for the project and represents the fuel being used by the majority of UK offshore wind support vessels [6] and accounts for 21.1% of global fuel demand [46].
Table 3.
Wärtsilä 6L25 2 MW technical data.
3.2. Exhaust Gas Thermal Energy Calculations
Calculating EG thermal energy (kW) is based on the 6L25 dataset provided by Wärtsilä [47] at load points of 50%, 75%, 85% and 100%. Table 4 lists exhaust gas parameters of a Wärtsilä 6L25. For simplicity purposes, the study will assess the WHR potential from a single 6L25 EG stream. Diesel electric OSV and SOV vessels are commonly fitted with 3–4 DG; however the variable vessel operational profile dictates that not all DG will be online concurrently.
Table 4.
6L25 Exhaust parameters at reported load points.
The exhaust gas thermal energy calculation will follow:
where
- ;
- ;
is defined as
where
Exhaust gas composition is variable based on engine loading. For simplification of calculations across all load points, is adopted [20]. The assumption is made that the engine will be fitted with an SCR system and installed on a vessel capable of operating in the North Sea SOx and NOx emissions control area (ECA) [48] and will be subject to NOx Tier III requirements [14]. The SCR is fitted after the engine T/C in the exhaust system and before the WHR high temperature heat exchanger (HTHX). In their study of a high-pressure SCR fitted to a two-stroke marine ICE, Xia et al. [49] reported an EG post SCR temperature drop of 20 °C at 25% load and a 10 °C increase at 100% load. SCR EG temperature drop data is limited for SCR fitted to a four-stroke marine ICE, as such a conservative 10 °C EG temperature drop across the SCR is assumed across all engine load levels. To prevent sulphuric acid formation in the exhaust system, EG temperature is kept above the acid dew point [24,26]. As fuel is ULSMGO, the minimum EG can be lower [26] and is set at 120 °C [13], .
3.3. ORC System Selection and Analysis
Selection of a suitable ORC system from those listed in Table 1 will be based on calculated EG thermal power. WHR from EG to the ORC system evaporator for this study will be via an intermediate heat transfer circuit. The heat transfer fluid temperature range will be determined by the selected ORC system. Figure 4 presents a schematic of an ORC WHR system with an intermediate heat transfer circuit. In the schematic, EG waste heat to the evaporator is supplied by an intermediate hot fluid (HF) circuit. The intermediate heater is the HG to hot fluid HTHX. Hot fluid is circulated via a feed pump to the ORC evaporator and back to the HTHX in a closed circuit. The ORC condenser is cooled via a cooling water circuit, either sea water, low temperature (LT) cooling water or another means. The ORC feed pump circulates the working fluid from the condenser to the evaporator and into the turbo generator in a closed system. The turbo generator produces the ORC electrical output.
Figure 4.
ORC system schematic [26].
Temperature loss across the heat transfer loop to the atmosphere via pipework and components is negated. As HF circulation is controlled via a pump, to maintain the required hot fluid flow mass flow rate at a given load point, a variable frequency drive is expected to be fitted to the pump. ORC working fluid is not reported due to variation between manufacturer selection.
The maximum hot fluid (water) inlet temperature is between 105 °C and 150 °C. To prevent boiling in the intermediate fluid loop, the water must be kept under pressure. To limit pressure requirements, 120 is selected as the maximum hot fluid temperature. Allowing a +7.5 tolerance, the hot fluid loop working pressure is set at 1.5 barG (2.5 BarA); under 1.5 barG, water will boil off at 127.5 . Hot fluid temperatures are set across all load points. The minimum hot fluid temperature is estimated based on an indicated of 45 across the evaporator hot fluid inlet and outlet of the ElectraTherm PM75 ORC [31]. The from the ElectraTherm PM75 ORC is used due to the large thermal input range of this model, 600–1600 kW, adopting the assumption that hot fluid will be similar to the other ORC units inventoried.
To establish the ORC net power output at each load point, it is necessary to calculate ORC thermal efficiency. ORC thermal efficiency can be calculated as follows:
where
is defined by the following energy equation:
where
is calculated as follows:
where
must be established at each thermal input point, as is not constant across the manufacturer-reported thermal input and power output ranges. Using the correlation between the minimum thermal input/power output and maximum thermal input/power output, power output at any thermal input can be calculated using the straight-line between two points equation:
where
- ;
3.4. High Temperature Heat Exchanger Calculations
A tube coil, crossflow, single pass HTHX design is selected for EG WHR, similar in construction to the cross-section of an Aalborg XW [50], shown in Figure 5. In this arrangement, there is a bank of plain tubes serpentine within an insulated enclosure. The tube is not a single continuous coil but several tubes connected at extreme ends via a common inlet and common outlet manifold. The number of transverse tubes is constrained by the HX width, and the length of each tube per row is constrained by the HX length. The HX height is determined by the total required heat transfer area. The HF passes through the tubes at a flow rate controlled via the HF loop circulation pump. EG gas passes over the tubes within the enclosure before exiting to the atmosphere.
Figure 5.
Aalborg XW tube coil construction [50].
Operational data presented by Ng, Tam and Wu [26] for their OSV study recorded that the highest load point was 85% for 2 DG online in Dynamic Positioning light mode, accounting for 30% of the total operational mode. An 85% load constitutes the lowest SFOC for the 6L25 study ICE, and accordingly, the HTHX is optimised for 85% load conditions.
Parameters for analytical calculations for EG and HF are presented in Table 5 and are taken at mean temperature values of HF; EG parameters are adopted from literature or approximated as air at mean temperature across HTHX at 85%, 1barA. It is assumed that there is ideal insulation with no heat loss to the atmosphere and a negligible fouling factor on heat transfer surface area. Additionally, pressure drop across the HTHX is negated, as inlet pressure is dependant on exhaust flue size and length, which is beyond the scope of the study.
Table 5.
EG and HF properties for HTHX modelling.
316L stainless steel [53] is selected as the tube material due to high corrosion resistance and good thermal conductivity, which make it suitable for use in the marine environment. Table 6 lists the initial geometry restrictions and 316L martial properties selected for the HTHX. Aluminium was considered but deemed unsuitable due to the high temperature, highly corrosive exhaust gas, marine environment and far higher coefficient of expansion than stainless steel, which could induce excessive material stress and fatigue.
Table 6.
HTHX geometry and material properties.
Calculations will be governed by the energy balance equation:
Expanding the equation gives the following:
is constant across the HTHX EG inlet and outlet at the corresponding load point. is an unknown variable and can be calculated by rearranging the equation:
In this scenario, as energy balance is maintained by variation in . remains constant at 45 . and will remain fixed at 75 and 120 respectively, as is varied at each load point and controlled by the circulation pump. Pump rating is commonly quoted in , and is converted to by the following equation:
HTHX design will follow the analytical NTU method widely adopted and presented in Incropera [51], using the NTU relationship as a function of HX effectiveness ( relating to crossflow, tubed heat exchangers [51]. NTU is estimated following the relationship graph; figure 11.14 is presented in Incropera for a single-pass, cross-flow heat exchanger with both fluids unmixed. NTU estimation requires calculation of and using the below equations, respectively.
where
and are calculated respectively as follows:
where
- is equal to the lowest heat capacity rate of or
- is equal to the highest heat capacity rate of or
Heat transfer area () is an unknown variable and must be calculated based on the geometry restrictions presented in Table 5 and NTU estimation. is calculated using the rearranged NTU formula for any HX:
represents the overall heat transfer coefficient in , referenced to the tube outer ( wall per unit area and is calculated by the following:
where
is calculated using the following:
and are calculated using the same fundamental convection heat transfer equation:
where
For , the EG Nusselt number () is calculated from the Zukaukas correlation formula to enable to be calculated as the average heat transfer coefficient over the entire tube bank of the HX [51]. The Zukaukas correlation formula is as follows:
where
- [51]
- [51].
Equation constants and are dependent on the calculated Reynolds . is calculated with the following formula:
is calculated as the maximum velocity over the tube bank using the following formula:
represents the EG velocity at the frontal entry region of the HX and is calculated as follows:
is calculated by the following formula:
can now be calculated using the following formula:
follows the same convective heat transfer formula in the following form:
is calculated using the formula for flow in plain tubes where the fluid is being heated:
is calculated from the following equation:
follows the same Prandtl number formula as for in the following form:
The overall geometry and final tube length can be calculated once the heat transfer area () has been found. Total tube length is calculated by the following:
must be able to coil within the constraints of and . The number of tubes able to fit transversely () is calculated by the following:
The number of tube rows () is established by the following formula:
Finally, the total height of the HX () required to fit is calculated by the following:
HX geometry will be evaluated to ensure reasonable size for the application. Through an iterative process using the above calculation methodology, HX geometry will be redefined to a reasonable size. Space constraints are unknown as available space varies depending on ship design; therefore, external surface area will be used as a metric for comparison. HTHX external surface area is calculated as follows:
3.5. Exergy Efficiency Calculations
Exergy analysis will encompass the exergy flow from EG to ORC output to quantify the overall exergy efficiency of the combined ICE-ORC system at stated load points.
Exergy efficiency can be defined as follows:
where
is calculated for each load point to quantify the at that specific load point. Dead state conditions for EG exergy calculations follow International Standard Atmosphere (ISA) properties at 0 m elevation. Exergy flow of individual ORC system components will not be reported on due to the inadequate data presented by commercial manufactures’ literature. Temperatures are converted from to Kelvin for exergy flow calculations.
The total exergy potential of the EG is calculated using the following formula:
In simplified terms,
Exergy flow is defined by the following formula:
value at the specified load point has been fixed as the mass flow rate reported by Wärtsilä.
3.6. SFOC Change
Table 2 reports ICE SFOC ( data from Wärtsilä at indicative load points and acts as the baseline data. To assess electrical power output from the ICE in the diesel generator configuration, an electrical efficiency factor of 0.96 [54] is applied. will be scaled to account for the efficiency reduction when converting mechanical power to electrical power to give . will then be compared with the calculated SFOC for the combined power output of the Wärtsilä 6L25 in DG configuration and ORC system. ICE power output is reported as mechanical power output ( at the flywheel [15]. Fuel consumption remains constant at each load point and is calculated based on mechanical power output. ORC electrical power output ( is completely dependent on WHR and requires no additional ICE fuel consumption.
SFOC for a given load point is calculated using the following equation:
where
is calculated using the following formula:
for a given load point is calculated using the following equation:
where
To establish the constant at each load point, the formula is rearranged as follows:
The constant will be calculated for load points at 50%, 75%, 85% and 100%.
The SFOC for combined and electrical output at a given load level is calculated by the following:
where
4. Results and Analysis
4.1. EG Thermal Energy
Following the equations presented in Section 3.2, EG energy is highest at 100% load, 962 , and lowest at 50% load, 50. This result is logically expected, as more fuel is combusted to maintain higher loads. Figure 6 presents a graph of EG energy and ICE energy as a function of ICE load.
Figure 6.
EG and ICE energy as a function of ICE load.
As Figure 1 shows, increases with load as expected. Table 7 shows the full data set of parameters and calculated thermal energy with corresponding temperatures and .
Table 7.
EG thermal energy calculated data.
EG temperature post SCR ranges from 310 to 355 ; however the lowest EG temperatures are at 75% and 85% load, both at 310 . The temperature data indicates that temperature does not increase linearly with load, suggesting that is more dependent on than temperature change. does increase with load, being highest at 100% at 3.72 and lowest at 2.28 for 50% load. The 6L25 is designed for a fixed 900 RPM operation across all load levels; therefore, is fixed at each load level, preventing further increases in EG energy. It is important to note that is constant. If was taken at each load point temperature mean value, will vary more than the values calculated.
4.2. ORC Selection and Power Output Analysis
The calculated EG energy range is from 501.6 to 961.62 kW. A review of ORC systems inventory from Table 1 shows that only the Orcan eP M 050.100 [30] has a suitable thermal input range corresponding to the calculated 6L25 EG energy range. The thermal input range of the Orcan eP M 050.100 is 500–1200 kW, and it has a reported power output of 50–100 kW. As 500 kW is the minimum thermal input, and at 50% load, the EG energy is 502 kW, the eP M 050.100 is incapable of producing power < 50%. At the ORC upper limit of 1200 kW thermal input, the max thermal input is ≈240 kW higher than the 962 kW EG energy at 100% load, meaning the ORC will theoretically produce power across the whole 50% to 100% EG energy range. Assuming a similar operational profile to the OSV profile presented by Ng, Tam and Wu [21], ICE DG will predominantly be loaded between 50 and 85%, with the bulk of ICE DG loading in the 75–85% range. The assumption indicated that the Orcan eP M 050.100 has the potential to produce power most of the time. Given the favourable thermal input range and power generation potential, the eP M 050.100 is feasible for the project continuation.
ORC power output and ORC efficiency at load points of 50%, 75%, 85% and 100% are presented in Figure 7. Power output ranges from 50.16 at 50% load to the maximum of 79.81 at 100% load. ORC efficiency ranges from 8.3% at 100% load to 10% at 50% load. At the 85% HTHX optimisation point, ORC power output is 66.19 with an efficiency of 9.10%. The results show a trend of decreasing efficiency as ORC power output increases; the highest efficiency is recorded at 50% load, whilst lower efficiency is at 100% load.
Figure 7.
ORC power and efficiency as a function of engine load.
4.3. HTHX Calculation Analysis
4.3.1. NTU Calculations
The 85% load point was used as the HTHX optimisation point. Using the NTU method, parameters of , , , and were calculated and are indicated in Table 8. These constants are independent of geometry parameters and used to estimate NTU, which is used in subsequent geometry iteration calculations.
Table 8.
HTHX NTU calculation variables.
was found as , meaning the minimum heat capacity rate was in the EG, which would be expected for a gas/water heat exchanger. , which is a result that indicates a high HT effectiveness, as is an ideal scenario. From , and an was corelated. For the crossflow, gas to water, single-pass HTHX where both fluids remain unmixed, an is acceptable. is generally undesirable due to a larger size increase with low efficiency gains [42]. The calculated is therefore within a realistic range and valid for use as a constant for HTHX geometry iteration calculations.
4.3.2. Iteration 1 Geometry Calculations
Finding , the initial geometry iteration calculation to find , then and finally was conducted. is dependent on , with requiring calculation of and . For iteration 1, and are set to 1.5 m, therefore giving . With set, was established using the calculated variables listed in Table 9.
Table 9.
heg1 calculated variables.
With established, followed using the variables calculated in Table 10. and are not dependant on . calculated variables are indicated in Table 11.
Table 10.
hhf calculated variables.
Table 11.
Rwall calculated variables.
, significantly larger than ; however this is expected due to being a liquid and being a gas. above is unusual for water in forced convection without a phase change. However, within the parameters defined for HF in Section 4.3, water is maintained under pressure to prevent boiling below 127.7 . A of the calculated magnitude is feasible given the fully developed high turbulent flow indicated by [51]. Calculated and presents minimal resistance to heat transfer from EG to HF.
From the above, calculated , and subsequently calculated . Using , calculated . appears very large and represents the total length of a single tube of ; however, the tube is not a single length fitted within the HTHX. The final bare HTHX geometry, and , are indicated in Table 12 alongside calculated and values.
Table 12.
HTHX iteration 1 geometry.
4.3.3. Iteration 2 Geometry Calculations
For iteration 2, and are set to 1 m, therefore giving . With set, was established using the calculated variables listed in Table 13.
Table 13.
heg2 calculated variables.
With , can be established as and variables are unchanged from iteration 1 as reported in Section 4.3.2. Calculated , and with remaining constant for both iterations, was defined as . From , . Iteration 2 final bare HTHX geometry, and , is indicated in Table 14 alongside calculated and values.
Table 14.
HTHX iteration 2 geometry.
4.3.4. HTHX Iteration Comparison
Results from geometry iterations 1 and 2 indicated that varying and has a significant effect on and the resultant and . Iteration 2 with a smaller produces much higher EG velocity values: and , being 8.53 higher than iteration 1 . The result is as higher degree of turbulent flow as , whereas iteration 1 . Correspondingly, for iteration 2, and , but for iteration 1, and . For iteration 2, is much higher and therefore required is lower. Iteration 1 requires more heat transfer surface area than iteration 2, which is a significant requirement in physical geometry and practical construction.
Both iteration 1 and 2 HTHX geometries are relatively compact; however, the physical dimensions of the iteration 2 HTHX geometry require less physical space. Iteration 2 whereas iteration 1 . That is a difference of in favour of iteration 2, which reflects the lower heat transfer surface area requirement.
4.4. Exergy Efficiency Analysis
Enthalpy, entropy, and at each load point were calculated as the required variable to calculate exergy flow input to the ORC. , and vary at each load point due to and changes, across all load points and remains constant. Figure 8 indicates the exhaust gas and at each load point. As expected, and are significantly larger due to higher than . The highest alongside the highest , both being at 100% load.
Figure 8.
EG exergy and exergy flow against engine load.
In terms of , the highest is at 100% load, a logical expectation. At the optimised 85% load point, , a difference of between 100% and 85% load. Figure 9 presents and (ORC power output) at the corresponding load points. ranges from at 50% load to 79.81 for 100% load with at 85% load. The range from 50% to 100% load is relatively narrow at only .
Figure 9.
ORC exergy flow input and output against engine load.
Figure 10 indicates the overall of the combined ICE WHR-ORC system and the corresponding at that load point. reduces with increased output, reducing from 24.5% at 50% load to 23.1% at 85% load and then 19.5% at 100% load. This constitutes a small change in of 5%.
Figure 10.
ORC exergy output and exergy efficiency against engine load.
As ORC efficiency reduces, power output increases as shown in Figure 6, the same trend would be expected for . The results show that for this ORC system, thermodynamic efficiency reduces with increased thermal input within the specified range. The reduction effect therefore impacts , as while the EG exergy increases with engine load, the ORC is less efficient at converting the energy into useful work, in this case electrical . The result indicates the importance of design optimisation and ORC selection for the expected ICE operating load range to recover as much exergy as possible to offset the relatively low factior.
4.5. SFOC Change Analysis
The SFOC of the combination DG-ORC system as compared to DG SFOC at each load point is presented in Figure 11. The highest SFOC combined is 189.91 at 50% load, following the highest DG SFOC of 197.40 at 50%. The lowest SFOC combined is 181.83.82 at 85% load, mirroring the lowest DG SFOC, which is at 85%. At the 85% load point, SFOC reduces by , showing a small improvement due to the additional power produced by the ORC system.
Figure 11.
SFOC ICE and combined against engine load.
The cause of the deceased SFOC combined is due to the additional power produced by the ORC despite no additional fuel being required by the ICE to produce that power. As the thermal energy of the EG is being turned into useful work, more fuel energy is essentially converted, although not directly in combustion, hence the mass of fuel required to produce a of work reduces. Despite ORC efficiency reducing with thermal input increases, from a SFOC combined perspective, 85% load remains the optimum level to utilise as much fuel mass in combustion to do useful work.
4.6. Results Calculations Summary
A summary of key results is presented in Table 15 and Table 16. Table 15 indicates a summary of iteration 1 and 2 HTHX heat transfer area using NTU and HTHX geometry. Table 16 presents key data relating to EG energy, exergy and SFOC corresponding to the applicable ICE load point.
Table 15.
Summary of key results of HTHX calculations.
Table 16.
Key results corresponding to ICE load of EG energy, exergy and SFOC.
5. Discussion
5.1. Findings
The project was able to quantify both exergy efficiency and SFOC change, and the results highlight several key findings and broader outcomes in marine ICE WHR via ORC systems. At the 85% load optimisation point, reasonable ORC power output of 66.19 kW is attained at and the lowest combined SFOC of 181.83 , a reduction of from DG SFOC. Whilst optimisation at 100% load would increase ORC power and cause only a slight increase in combined SFOC to , the operational data from Ng, Tam and Wu [25] shown in Figure 2 indicates that 100% load is never achieved, nor is 100% load operation common practice. Therefore, from a system analysis perspective, it would not be realistic to design a WHR ORC system based on ICE operation as 100% load.
In terms of the HTHX, iteration 2 with a reduced EG frontal area produced a lower heat transfer area requirement, , compared to iteration 1, resulting in a smaller geometry and a lower HTHX external surface area, . Had the HTHX been optimised for 100% load and therefore the increased EG thermal energy, a larger HTHX would be required, but as discussed, 100% ICE load is rare, and it would make little logic to optimise for a situation that has little operational occurrence. In this scenario, however, again from a system analysis perspective, an EG HTHX bypass would be required to managed EG flow to maintain 85% load conditions at the HTHX if loading does temporarily increase. Additionally, the was based on the ElectraTherm PM75 ORC. The assumption detailed in Section 3.3 is that the will be similar to the other ORC units inventoried. The HTHX results shown are based on this assumption and should be used as an initial reference. A detailed design HTHX applicable for selected Orcan eP M 050.100 may vary the HTHX requirements based on manufacturer data.
The results indicate that is highest at 50% load, , and lowest at 100% load, . The opposite is the case for combined SFOC, being highest at 50% load and only marginally higher at 100% load, 187.91 and , respectively. This is important as the higher exergy efficiency is effectively offset by the higher combined SFOC. To what extent, however, is not within the results reported. An ideal circumstance would be to have the highest at the lowest combined SFOC, but it is generally a compromise between these two factors. It should be noted that the efficiency 0.96 when converting from ICE mechanical power to electrical power increases SFOC in the DG configuration, as relatively less fuel is used for useful work. Regardless, the ORC is still able to produce at 50% load, recovering exergy that would otherwise be lost despite the higher SFOC. The exergy efficiency is representative of the ORC efficiency, in this case the Orcan eP M 050.100, which was selected purely based on thermal input range. Alternative ORC systems, operating with different working fluids or different thermal transfer methods, may improve upon the reported . When evaluating an ORC system, it would be sound engineering practice to consider both thermal input range and ORC efficiency when undertaking a system analysis.
The ORC net power output results show that from 50% to 100% ICE load, EG thermal energy can be harnessed to produce usable power from to 79.81 . While the ORC net power output is reported, accounting for the ORC internal feed pump, the electrical power required to run the hot fluid circuit feed pump is not included. This leads to an overestimation of usable ORC net power. Power required to run the hot fluid circuit feed pump is variable and is not reported in this study.
When these results are applied to Ng, Tam and Wu [26]’s OSV case study data presented in Figure 2, the load range at which the ORC can produce power matches the load range the case study OSV ICEs primarily operate in: 50% to 85%. The finding shows that when selecting an ORC as part of a WHR system, operational data is of extreme importance to ensure that the ORC can produce power that aligns to the actual ICE load points. A noteworthy factor is that the project presents a single DG paired with a single ORC WHR system, whereas in the OSV case’s vessel [26], multiple DGs run in parallel, typically two or four. In such installations, multiple or combined EG WHR ORC systems could operate, recovering more exergy and producing additional useable power.
5.2. Method Validation
The project methods were able to produce results that are sensible given the limited data available. The results were obtained under ideal circumstances and assumptions based on the range of data available. The results are valid when applied to the Wärtsilä 6L25 marine ICE in combination with the Orcan eP M 050.100 via the WHR HTHX presented in this project. Under the ideal circumstances, 100% thermal energy transfer between the exhaust gas and hot fluid was maintained by calculation of required hot fluid mass flow rate using the energy balance principle. The HTHX calculations did not factor in a fouling factor and heat losses to the atmosphere. No HTHX is 100% efficient in practice, and heat losses to the atmosphere occur depending on the quality of insulation used, which is a design and cost choice. Fouling occurs from EG particulate matter buildup and heat transfer surfaces; however, marine EG economisers feature steam or ultrasonic soot blowers to minimise fouling. Similarly, heat loss and frictional losses in the heat transfer loop were ignored, as these are dependent on pipework layout and material choice. HF circulation pump power demand was not factored in for the same reason. The added complexity of such factors was beyond the scope of the project.
The main equation sets utilised are well established. Energy balance is a core principle of thermodynamics, and the NTU method is the common method of heat exchanger calculations where software is not used. SFOC is a key metric to quantity fuel consumption of marine ICE and has been adopted as a comparative metric to assess the combined ICE WHR ORC system presented in this study. Exergy efficiency calculations follow standard methods. Best engineering judgement was used to assist in evaluation of non-standard outcomes such as HTHX geometry evaluation and quantifying ORC metrics of power output at the given thermal input and efficiency using the available data.
5.3. Contributions
The project aimed to incorporate an element of practicality in the implementation of WHR ORC systems for smaller ICE-powered vessels in system analysis studies. The project and results provide a starting point for OSV and SOV shipowners wishing to retrofit or fit ORC-based EG WHR systems. By quantifying exergy efficiency and combined SFOC using a commercial ICE and ORC, shipowners can evaluate the potential of the technology from equipment available to them or similar to that already installed on their vessels. The complexity of WHR systems is addressed in large part by this project, allowing shipowners to make rough evaluations for their own system analysis. By providing base data and results, shipowners’ technical teams can have a clearer understanding of EG WHR ORC systems in preparation for working with shipyards and equipment suppliers. The projects adds to the increasing research into smaller EG WHR ORC systems for not only SOVs and OSVs but other diesel electric vessels or smaller vessels utilising ICE similar in power output to the Wärtsilä 6L25.
The limitations of the project, however, will require study to optimise retrofits and realise losses and actual potential of EG WHR once full datasets and design specifications are established. Similarly, the theoretical heat exchanger design lacks the complexity of commercial designs that would be used by shipowners and should be for guidance for commercial HTHX selection. Full real-world vessel operational profiles and vessel design are missing as a basis for the project, which have restricted the potential to produced optimised and further realistic results.
6. Conclusions
This project presents a system analysis of an ORC system utilising EG waste heat from a marine four-stroke ICE, a Wärtsilä 6L25, in the diesel generator configuration typical of the type installed in offshore, diesel electric vessels. The project aim was to quantify the ORC-DG WHR system exergy efficiency and combined system SFOC at varied loads.
The main conclusions are as follows:
- ORC WHR systems combined with smaller power output marine ICE are underreported compared to two-stroke ICE, seemingly owing to a lack of real-world operational data and use cases. As such, it appears from the completed ORC inventory that systems compatible for use with the EG thermal input ranges of these ICE are limited in the market.
- The HTHX was optimised for 85% ICE loading rather than a theoretical 100%. The decision was based on lowest ICE SFOC and OSV operational data indicating that actual ICE loading predominately sits between 75% and 85%. Optimisation of HTHX should therefore be sized on actual expected loading conditions and ideal SFOC with a suitable EG bypass, which will reduce size and underutilisation of the HTHX.
- Exergy efficiency was highest at 50% load and lowest at 100% load, and respectively, representing a minimal variance. At 75% and 85%, and , with an ORC and . Despite the relatively low , a respectable is achieved, showing that exergy recovery is potentially feasible by the system presented in the project.
- The lowest combined ORC-DG SFOC was indicated at 85% load, 181.83 , a reduction of from DG SFOC, which is a relatively small decrease; however, combined SFOC could be improved with an increase in . The trend does correlate with 85% load producing the lowest DG SFOC, suggesting that optimisation of the ORC system should consider both real operational profiles and lowest SFOC to maximise exergy recovery and efficiency.
The results suggest the suitability of integrating the ORC system presented to provide additional electrical power, improve exergy efficiency and lower SFOC. The project aims were purely to quantify these changes using available data, but the results are a positive indication of ORC systems for smaller four-stroke ICE EG WHR in the DG configuration. The findings presented are based on theoretical analysis with limited real operational data. Future research should advance and validate the study by software modelling utilising full operational data from suitable case study vessels and manufacturers’ equipment data from Orcan.
Author Contributions
Conceptualization, J.J.T.H.-F. and U.A.; methodology, J.J.T.H.-F.; validation, J.J.T.H.-F. and U.A.; formal analysis, J.J.T.H.-F.; investigation, J.J.T.H.-F.; resources, W.M.C.; data curation, J.J.T.H.-F.; writing—original draft preparation, J.J.T.H.-F.; writing—review and editing, U.A. and W.M.C.; supervision, U.A.; project administration, W.M.C. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding authors.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| DG | diesel generator |
| DNV | Det Norske Veritas |
| DynPos | Dynamic Positioning |
| ECA | emissions control area |
| EG | exhaust gas |
| GHG | greenhouse gas |
| HF | hot fluid |
| HTHX | high temperature heat exchanger |
| IACS | International Association of Class Societies |
| ICE | internal combustion engine |
| IMO | International Marime Organisation |
| LFO | light fuel oil |
| LMTD | Log Mean Temperature Difference |
| NTU | Number Transfer Units |
| ORC | Organic Rankine Cycle |
| OSV | offshore support vessel |
| O and M | operation and maintenance |
| SCR | Selective Catalytic Reactor |
| SFOC | specific fuel oil consumption |
| SOLAS | Safety of Life at Sea |
| SOV | service operations vessel |
| T/C | turbo charger |
| ULSMGO | ultra-low sulphur marine gas oil |
| UN | United Nations |
| WHR | waste heat recovery |
References
- UN. TRANSFORMING OUR WORLD: THE 2030 AGENDA FOR SUSTAINABLE DEVELOPMENT. 2015. Available online: https://sdgs.un.org/sites/default/files/publications/21252030%20Agenda%20for%20Sustainable%20Development%20web.pdf (accessed on 13 May 2026).
- IMO. MEPC.377(80); International Maritime Organisation: London, UK, 2023. [Google Scholar]
- International Maritime Organisation. Fourth IMO GHG Study 2020. 2021. Available online: https://wwwcdn.imo.org/localresources/en/OurWork/Environment/Documents/Fourth%20IMO%20GHG%20Study%202020%20-%20Full%20report%20and%20annexes.pdf (accessed on 21 February 2026).
- Section for Maritime Management. The Government’s Action Plan for Green Shipping. Available online: https://www.regjeringen.no/contentassets/2ccd2f4e14d44bc88c93ac4effe78b2f/the-governments-action-plan-for-green-shipping.pdf (accessed on 17 March 2026).
- Department for Transport. Maritime Decarbonisation Strategy. Available online: https://assets.publishing.service.gov.uk/media/67f4dcb3c2fea2548f4eff64/dft-maritime-decarb-strategy-25.pdf (accessed on 17 February 2026).
- Offshore Renewable Energy Catapult. Decarbonising Maritime Operations in North Sea Offshore Wind O&M. Available online: https://www.gov.uk/government/publications/decarbonising-offshore-wind-operations-and-maintenance-roadmap (accessed on 17 February 2026).
- ScienceDirect. Specific Fuel Consumption—An Overview. Available online: https://www.sciencedirect.com/topics/engineering/specific-fuel-consumption (accessed on 27 May 2026).
- ScienceDirect. Potential Exergy—An Overview. Available online: https://www.sciencedirect.com/topics/engineering/potential-exergy (accessed on 27 May 2026).
- DNV AS. Energy Efficiency Measures and Technologies. 2025. Available online: https://www.dnv.com/maritime/publications/energy-efficiency-report-download/ (accessed on 8 March 2026).
- Ma, R.; Zhao, Q.; Wang, K.; Cao, J.; Yang, C.; Hu, Z.; Huang, L. Energy efficiency improvement technologies for ship in operation: A comprehensive review. Ocean Eng. 2025, 331, 121258. [Google Scholar] [CrossRef] [Scilit]
- Singh, D.V.; Pedersen, E. A review of waste heat recovery technologies for maritime applications. Energy Convers. Manag. 2016, 111, 315–328. [Google Scholar] [CrossRef] [Scilit]
- Konur, O.; Colpan, C.O.; Saatcioglu, O.Y. A comprehensive review on organic Rankine cycle systems used as waste heat recovery technologies for marine applications. Energy Sources Part Recovery Util. Environ. Eff. 2022, 44, 4083–4122. [Google Scholar] [CrossRef] [Scilit]
- Sánchez-Lozano, D.; Aguado, R.; Escámez, A.; Hernández-Torres, J.A.; Torreglosa, J.P.; Vera, D. Integrating organic Rankine cycles for waste heat recovery from onboard diesel generators in the maritime sector: Simulation and techno-economic assessment. Energy Convers. Manag. 2025, 339, 119859. [Google Scholar] [CrossRef] [Scilit]
- IMO. MEPC.328(76); International Maritime Organisation: London, UK, 2021. [Google Scholar]
- Wärtsilä. Wärtsilä 25 Product Guide. Wärtsilä Finland Oy, 5 February 2025. Available online: https://brandhub.wartsila.com/m/69562bb533b47695/original/Wartsila-25-Product-guide.pdf (accessed on 21 February 2026).
- IACS. Unified Requirements: Minimum Safety Standards for Ships, Safer and Cleaner Shipping—IACS. Available online: https://iacs.flumeserver.co.za/unified-requirements/ (accessed on 10 September 2026).
- IACS. Clearer IMO Regulations for Ships: Unified Interpretations—IACS, Safer and Cleaner Shipping—IACS. Available online: https://iacs.flumeserver.co.za/unified-interpretations/ (accessed on 10 September 2026).
- IMO. International Convention for the Safety of Life at Sea (SOLAS), 1974. Available online: https://www.imo.org/en/about/conventions/pages/international-convention-for-the-safety-of-life-at-sea-(solas),-1974.aspx (accessed on 10 September 2026).
- IImo, M.S.C. 1-Circ.1212-Rev.1—Revised Guidelines On Alternative Design And Arrangements For Solas Chapters Ii-1 And Iii (Secretariat); International Maritime Organisation: London, UK, 2019; Available online: https://www.crclass.org/wp-content/uploads/ti-tc/106/2-1%20MSC.1-Circ.1212-Rev.1%20-%20Revised%20Guidelines%20On%20Alternative%20Design%20And%20Arrangements%20For%20Solas%20Chapters%20Ii-1%20And%20Iii%20(Secretariat).pdf (accessed on 10 September 2026).
- Song, J.; Song, Y.; Gu, C. Thermodynamic analysis and performance optimization of an Organic Rankine Cycle (ORC) waste heat recovery system for marine diesel engines. Energy 2015, 82, 976–985. [Google Scholar] [CrossRef] [Scilit]
- Zhang, X.; Cao, M.; He, M.; Wang, J. Thermodynamic and Economic Studies of a Combined Cycle for Waste Heat Recovery of Marine Diesel Engine. J. Therm. Sci. 2022, 31, 417–435. [Google Scholar] [CrossRef] [Scilit]
- Sabir, S.; De, S.; Mondal, S. Enhanced waste heat recovery from a marine diesel engine with multi-pressure transcritical regenerative ORCs for reduced carbon emissions. Energy Sources Part Recovery Util. Environ. Eff. 2025, 47, 2541871. [Google Scholar] [CrossRef] [Scilit]
- Lebedevas, S.; Čepaitis, T. Complex Use of the Main Marine Diesel Engine High- and Low-Temperature Waste Heat in the Organic Rankine Cycle. J. Mar. Sci. Eng. 2024, 12, 521. [Google Scholar] [CrossRef] [Scilit]
- Lyu, L.; Kan, A.; Chen, W.; Zhang, Y.; Fu, B. Energy, Exergy and Environmental Analysis of ORC Waste Heat Recovery from Container Ship Exhaust Gases Based on Voyage Cycle. J. Mar. Sci. Eng. 2023, 11, 2029. [Google Scholar] [CrossRef] [Scilit]
- Shu, G.; Liu, P.; Tian, H.; Wang, X.; Jing, D. Operational profile based thermal-economic analysis on an Organic Rankine cycle using for harvesting marine engine’s exhaust waste heat. Energy Convers. Manag. 2017, 146, 107–123. [Google Scholar] [CrossRef] [Scilit]
- Ng, C.; Tam, I.C.K.; Wu, D. Thermo-Economic Performance of an Organic Rankine Cycle System Recovering Waste Heat Onboard an Offshore Service Vessel. J. Mar. Sci. Eng. 2020, 8, 351. [Google Scholar] [CrossRef] [Scilit]
- Zahedi, B.; Norum, L.E.; Ludvigsen, K.B. Optimized efficiency of all-electric ships by dc hybrid power systems. J. Power Sources 2014, 255, 341–354. [Google Scholar] [CrossRef] [Scilit]
- Alfa Laval. E-PowerPack. Available online: https://www.alfalaval.com/globalassets/documents/products/heat-transfer/power-generator/e-powerpack/alfa-laval-e-powerpack_product-leaflet_en.pdf (accessed on 27 April 2026).
- Climeon. The Climeon HP 150. Available online: https://climeon.com/wp-content/uploads/2020/04/Climeon-HP-150-3.4_web.pdf (accessed on 27 April 2026).
- Climeon. The Climeon HP 300. Available online: https://climeon.com/heatpower-300-technology/ (accessed on 27 April 2026).
- ElectraTherm. ElectraTherm PM75. Available online: https://electratherm.com/wp-content/uploads/2025/07/PM75_web.pdf (accessed on 27 April 2026).
- ElectraTherm. ElectraTherm 6500B. Available online: https://electratherm.com/wp-content/uploads/2025/07/6500B_web.pdf (accessed on 27 April 2026).
- Enogia. ORC EN0-40LT. Available online: https://enogia.com/wp-content/uploads/2025/01/40LT-EN-1.pdf (accessed on 27 April 2026).
- Enogia. ‘ORC EN0-100LT’. Available online: https://enogia.com/wp-content/uploads/2025/01/100LT-EN-1.pdf (accessed on 27 April 2026).
- Orcan Energy. Orcan eP M 050.100. Sveadiesel AB. Available online: https://sveadiesel.se/en/turbines-orc-modules-2/orc-module/orcan-ep-m-050-100/orcan-ep-m-050.100-epm050-100/#/beskrivning|tekniska-data|dokument (accessed on 13 April 2026).
- Orcan Energy. Orcan eP M 150.200. Orcan Energy. Available online: https://sveadiesel.se/en/turbines-orc-modules-2/orc-module/orcan-ep-m-150-200/orcan-ep-m-150.200-epm150-000/#/beskrivning|tekniska-data|dokument (accessed on 27 April 2026).
- PanAsia. Pan-ORC1. Available online: https://www.worldpanasia.com/upload_files/board/CATALOG/o_1j9ed07vekr03ofp837lc1427a.pdf (accessed on 27 April 2026).
- Kongsberg. Switchboard. Available online: https://www.kongsberg.com/contentassets/0e467f974d7946968596bfdd2423651e/image6vvs.png?w=1500 (accessed on 2 June 2026).
- ABB. Three-Phase Alternator AMG Series. Available online: https://www.directindustry.com/prod/abb-motors-drives-power-electronics/product-30286-2320964.html (accessed on 2 June 2026).
- Wartsila. NOx Reducer. Available online: https://www.wartsila.com/images/default-source/products/engines-generating-sets/wartsila-nox-reducer-banner.tmb-1920x690.jpg?sfvrsn=58742343_1 (accessed on 2 June 2026).
- Desmi, M.V. Multistage Centrifugal Pump. Available online: https://www.desmi.com/media/ngldjdwf/desmi_mv25b_v2_new_open_blue-new.png?width=640&height=448&format=webp&quality=80&v=1dcb2c879170f70 (accessed on 2 June 2026).
- Kongsberg. US Type Azimuth Thruster. Available online: https://www.kongsberg.com/contentassets/5ac8de0e9ff144f0a65081a8f9015dd2/collar_main.jpg (accessed on 2 June 2026).
- Wartsila. Wartsila 6L25 44. Majesty, Exhaust Control Valve. Available online: https://www.wartsila.com/images/default-source/products/engines-generating-sets/medium-speed-engines/wartsila-25-engine.png?sfvrsn=327b2b43_3 (accessed on 2 June 2026).
- Majesty. Exhaust Control Valve. Available online: https://images.nexusapp.co/assets/2e/4e/4a/22789744.jpg (accessed on 2 June 2026).
- BS ISO 8217:2024; Products from Petroleum, Synthetic and Renewable Sources. Fuels (Class F). Specifications of Marine Fuels. BSI: Hong Kong, China, 2024. Available online: https://bsol.bsigroup.com/Bibliographic/BibliographicInfoData/000000000030419787 (accessed on 19 March 2026).
- IRENA. A Pathway to Decarbonise the Shipping Sector by 2050. Available online: https://www.irena.org/-/media/Files/IRENA/Agency/Publication/2021/Oct/IRENA_Decarbonising_Shipping_2021.pdf (accessed on 21 March 2026).
- Wärtsilä. 6L25 EngineData. 5 February 2025. Available online: https://www.wartsila.com/marine/engine-configurator?Application=Generating+set+auxiliary&Frequency=60&Fuel+type=Marine+diesel+oil&Power=740%2C2543&Emission=IMO+Tier+3 (accessed on 21 February 2026).
- IMO. Circular Letter No.5085; International Maritime Organisation: London, UK, 2025. [Google Scholar]
- Xia, C.; Zhu, Y.; Zhou, S.; Peng, H.; Feng, Y.; Zhou, W.; Shi, J.; Zhang, J. Simulation study on transient performance of a marine engine matched with high-pressure SCR system. Int. J. Engine Res. 2023, 24, 1327–1345. [Google Scholar] [CrossRef] [Scilit]
- Alfa Laval. Aalborg XW. Available online: https://www.alfalaval.com/products/heat-transfer/boilers/exhaust-gas-economizer/aalborg-xw/ (accessed on 7 May 2026).
- Bergman, T.L.; Incropera, F.P.; DeWitt, D.P.; Lavine, A.S. Incropera’s Principles of Heat and Mass Transfer, Global Edition, 8th ed.; Wiley: Hoboken, NJ, USA, 2017. [Google Scholar]
- Çolak, K.; Ölmez, H. Thermodynamic and feasibility analysis of using diesel generator exhaust gases for ship main engine preheating at port periods. Appl. Therm. Eng. 2023, 235, 121429. [Google Scholar] [CrossRef] [Scilit]
- AZO Materials. Stainless Steel—Grade 316 (UNS S31600). Available online: https://www.azom.com/properties.aspx?ArticleID=863 (accessed on 14 May 2026).
- Wärtsilä. Wärtsilä Genset Solutions – W25. Available online: https://www.wartsila.com/marine/products/engines-and-generating-sets/generating-sets/wartsila-gensets (accessed on 25 March 2026).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.