Abstract
Explainable AI (XAI) maps are often judged by whether they highlight what a human would look at, but this is rarely tested against recorded eye movements. This exploratory benchmark compared the fixations of a single annotator from the open GazeMedSeg dataset (26,832 fixations on 1000 Kvasir-SEG colonoscopy images, recorded while the annotator located and then scanned a polyp present in every image) with seven attribution methods for three polyp segmentation U-Nets (test Dice 0.829 ± 0.004). The first fixation fell on the polyp in 45% of images and the second in 93% of images, and 85–91% of fixations in each later fixation-order group fell inside it. Over the whole image, decoder-layer Grad-CAM agreed best with gaze among the explanations (correlation 0.62; 0.65 at matched resolution), yet the model’s own probability map agreed slightly better (paired difference −0.023, 95% CI −0.032 to −0.013). Inside the lesion, no method showed statistically significant positive residual agreement with gaze after the tested geometry controls. The most faithful methods in deletion–insertion tests (GradientSHAP, Integrated Gradients) were among the least aligned with gaze, but the faithfulness ranking depended on the test protocol, and gradient-based maps failed a model-randomisation check. Gaze-based evaluation of segmentation explanations therefore needs a model-output baseline, resolution-matched maps and geometry-controlled within-lesion analysis; the findings are specific to one annotator, task-directed viewing and one architecture.
1. Introduction
Colonoscopy is the reference standard for colorectal cancer screening, yet a meta-analysis of tandem studies estimated that about one in four adenomas is missed during a single examination [1]. Deep learning models, now applied across medical image analysis [2], are therefore attractive as a second reader for polyp detection and segmentation. Their clinical uptake depends on whether endoscopists can understand and trust what the model is responding to, a recurring barrier to AI adoption in healthcare [3], and post hoc explainable AI (XAI) methods such as Grad-CAM, gradient attribution and occlusion are the usual answer [4].
An explanation can be judged on two different properties. Faithfulness asks whether the map reflects the computation the model actually performed. Plausibility asks whether the map is convincing to a human [5]. The two can diverge: a map can be faithful yet highlight regions a clinician would never consult, or look persuasive yet be insensitive to the model’s parameters [6,7]; widely used post hoc methods such as Grad-CAM and SHAP often fail faithfulness checks in medical imaging [8]. Most medical XAI evaluations approximate plausibility by agreement with expert-drawn masks or bounding boxes [9,10]. A mask records where the lesion is. It does not record how a viewer distributes visual attention across and around the lesion while examining it.
Eye tracking measures where a viewer looks. Work in medical image perception shows that fixation patterns differ systematically with expertise and relate to diagnostic performance [11,12]. In colonoscopy, gaze patterns have been linked to polyp detection rates [13], and eye-tracking data recorded during simulated colonoscopy can identify moments when trainees struggle [14]. Recorded gaze is therefore a behavioural reference against which explanation maps can be compared. In this paper, that comparison is called gaze agreement: an operational proxy for one aspect of plausibility, namely spatial correspondence with where a human looked. It is not a measure of whether a clinician finds an explanation convincing, understandable or useful. Until recently, public medical gaze datasets were concentrated in chest radiography, and the most widely used ones require credentialed access [15]. GazeMedSeg [16] provides openly downloadable fixation sequences for all 1000 images of the Kvasir-SEG polyp dataset [17].
The closest precedent compared radiologists’ gaze on 91 chest radiographs (five readers) with Grad-CAM and attention maps of a classification network, using shuffled metrics to control centre bias and an inter-observer reference as an upper bound [18]. The original GazeMedSeg study used gaze as weak supervision for segmentation rather than to evaluate explanations [16]. This study asks, in an exploratory setting, whether explanations of a polyp segmentation network agree with the gaze of the GazeMedSeg annotator, and what that agreement means. Relative to the precedent, it adds a segmentation task in endoscopy, a model-output baseline that tests whether an explanation agrees with gaze better than the prediction it explains, a within-lesion analysis with a geometry control that tests what gaze adds beyond the lesion outline, and a joint analysis in which annotator gaze is scored by the same faithfulness tests as the explanations. Because the gaze comes from one annotator who was instructed to locate and then scan a polyp known to be present, the study is a methodological benchmark and does not characterise how gastroenterologists search during clinical colonoscopy.
The contributions are:
- A gaze-agreement benchmark of seven attribution methods for polyp segmentation, with chance, empirical-gaze-prior, geometric-centre, model-output, lesion-mask and boundary-distance reference maps, resolution-matched comparisons and variability across three independently trained networks.
- A two-level analysis that reports whole-image and within-lesion agreement separately, and a geometry-controlled within-lesion analysis that tests whether agreement inside the lesion exceeds what lesion shape alone predicts.
- A descriptive analysis of the eye-movement record (fixation counts, durations, entry into the lesion) that links the annotation protocol to the interpretation of gaze agreement.
- A joint gaze-agreement and faithfulness analysis in which annotator gaze, the lesion mask and each XAI map are scored by the same deletion and insertion tests, with an aligned target, an alternative replacement scheme, and sanity and convergence checks of the attribution methods.
Both datasets are public. Code, split files, trained networks, the software environment and per-image results are released (see the Data Availability Statement), so the analyses can be reproduced on a standard CPU.
2. Related Work
2.1. Eye Tracking in Medical Image Interpretation
Eye tracking has been used to study medical image perception since the early work of Kundel and colleagues on pulmonary nodule search, which separated global impression, focal scanning and decision stages [19]. Reviews across radiology, pathology and endoscopy report that experts reach relevant regions faster, use fewer fixations and dwell longer on diagnostically informative areas [11,12,20]. Recent work has linked fixation measures to neurosurgical expertise in brain MRI [21] and scanpath variability to errors in clinical ECG interpretation [22]. In colonoscopy, endoscopists with higher polyp detection rates show more systematic, peripheral search of the bowel wall [13]. Eye movements also serve as an input channel in assistive technology, for example, to steer a wheelchair with the eyes [23].
Public gaze datasets have enabled machine learning work on top of these recordings. EGD-CXR [24] and REFLACX [25] pair chest radiographs with radiologist fixations and dictated reports, and both are distributed under credentialed access. A systematic review counts only a handful of public medical gaze datasets and notes their concentration in chest radiography [15]. GazeMedSeg [16] adds openly downloadable gaze for endoscopic polyp images and prostate MR slices.
2.2. Gaze as Supervision Versus Gaze as Evaluation
Most machine learning studies use gaze as a training signal: as weak labels for classification [26], as an attention prior that guides a network toward clinically relevant regions [27], or as dense weak supervision for segmentation [16]. Using gaze to evaluate explanations of a model trained without gaze is less explored. The distinction matters: when gaze is used for training, agreement between model attention and gaze is partly built in; when it is used only for evaluation, agreement indicates that model and viewer converge on the same image regions without having been trained to do so. Bigolin Lanfredi et al. [18] compared the gaze of five radiologists on chest radiographs with saliency maps of a classifier and found that the maps agreed with gaze less well than radiologists agreed with one another, a reference that the single-annotator data used here cannot provide. Outside medicine, the class activation maps of a network that grades student design work were compared with viewers’ eye-movement heat maps, showing agreement on key focal regions but divergence in background viewing [28]. AI-based attention-prediction tools are also used in place of recorded eye tracking to estimate where viewers look and how much cognitive load a design imposes, for example in online learning materials, digital magazines and retail displays [29,30,31]; predicted-attention maps of this kind raise the same validation question as explanation maps, namely how closely they agree with recorded human fixations. Explainability methods are also increasingly applied to eye-tracking data themselves, for example, SHAP analysis linking drivers’ gaze-based visual load to road-scene features [32].
2.3. Evaluating Saliency and Attribution Maps
Grad-CAM [33] and its segmentation adaptation, Seg-Grad-CAM [34], are the most widely used explanations in medical imaging, and Grad-CAM and occlusion are also used to inspect models of physiological signals [35]. Their reliability has been questioned on two fronts. Sanity checks show that some methods are largely insensitive to model weights [7], and perturbation benchmarks show that attribution rankings depend on the evaluation protocol [36,37]. On the plausibility side, large benchmarks in chest radiography found that saliency maps localise pathology worse than radiologists and worse than model-free baselines in several cases [9,10].
The eye-movement community has mature tools for comparing a predicted map with human fixations [38,39]. Location-based metrics (AUC-Judd, normalised scanpath saliency) score the map at fixated pixels; distribution-based metrics (correlation coefficient, similarity, Kullback–Leibler divergence) compare the map with a smoothed fixation density. These metrics reward central maps because human fixations are biased towards the image centre [40,41,42], so a centre-bias baseline is required for interpretation [39,43]. Data-driven alternatives that compare gaze allocation between conditions with classifiers have also been proposed [44]. This study adopts the standard metric toolkit, defines each implementation choice explicitly (Section 3.7), and adds baselines that address the specific confounds of lesion-focused gaze.
3. Materials and Methods
3.1. Data
Images and masks. Kvasir-SEG [17] contains 1000 colonoscopy images of polyps, each with a pixel-level polyp mask verified by an experienced gastroenterologist. Native image sizes range from 352 to 1072 pixels in height and from 332 to 1920 pixels in width; the median width-to-height ratio is 1.155 (IQR 1.124–1.174). Kvasir-SEG does not release patient identifiers.
Eye-tracking data. GazeMedSeg [16] provides one fixation sequence for each of the 1000 Kvasir-SEG images (26,832 fixations), all from the same annotator. The released files give, for each fixation, normalised image coordinates, duration, pupil size, order and onset time; raw gaze samples are not released.
3.2. Eye-Tracking Acquisition as Reported by the Dataset Authors
Because this is a secondary analysis, acquisition details are taken from the GazeMedSeg publication and its appendix [16] and from the dataset repository; the description below distinguishes between what those sources report and what they do not. Gaze was recorded monocularly from the dominant eye with an EyeLink 1000 Plus (SR Research Ltd., Ottawa, ON, Canada) at 1000 Hz, with a reported tracking error of at most 0.5°. Images were shown one at a time, centred at 768 × 768 pixels on a 21.5-inch monitor running at 1024 × 768 pixels and 60 Hz, at a viewing distance of 46–55 cm with a chin rest. The experiment was built in SR Research Experiment Builder; a 9-point calibration was performed at the start of the session, and viewing was self-paced (the annotator pressed a key to advance), so presentation duration varied by image. The annotator wore no glasses (contact lenses were permitted) and is described as experienced in medical imaging and trained for eye-tracking recordings; no clinical speciality is stated, so endoscopy expertise is not assumed. The annotation followed a two-stage instruction: first locate the polyp, then scan it thoroughly, typically moving from its centre towards its boundary. The repository states that fixations shorter than 50 ms and fixations outside the image were removed.
The sources do not report a validation step after calibration, drift checks, whether a central fixation marker preceded each image, the fixation-detection algorithm or its parameters, the verbatim instruction text, or any screening of visual acuity or colour vision. None of these can be recovered from the downloaded files, which contain fixations rather than samples. Colour-vision status matters in principle because polyps are distinguished from mucosa partly by colour; it is not documented and could not be assessed.
With the reported 21.5-inch screen at 1024 × 768 pixels, one screen pixel measures about 0.427 mm, so the 768-pixel image spanned about 32.8 cm, or 33–39° of visual angle at the reported viewing distance of 46–55 cm. One degree therefore corresponds to 2.45% (at 46 cm) to 2.93% (at 55 cm) of the displayed image width. The reported tracking error of at most 0.5° corresponds to 9.4–11.3 screen pixels, or 1.2–1.5% of image width; at the 192 × 192 resolution used for analysis (one analysis pixel = four displayed pixels), this is 2.3–2.8 pixels. Differences in where fixations fall on a finer spatial scale than this cannot be resolved by these data.
3.3. Preprocessing, Split and Duplicate Screening
Images were resized directly to 192 × 192 pixels with area interpolation and masks with nearest-neighbour interpolation, without cropping or padding. Because the native images are wider than they are tall, this compresses the horizontal axis by about 13% at the median aspect ratio. Fixation coordinates are released normalised to image width and height, so they were mapped to the resized grid by multiplying by 192 and truncating to integer pixel indices from 0 to 191; fixations, masks and images therefore undergo the same anisotropic scaling and remain registered. The black borders and on-screen text present in some Kvasir-SEG images were retained.
Images were split once, using a random permutation with seed 42 (NumPy RandomState), into 700 training, 100 validation and 200 test images; the same split was used for every network, and the image identifiers of each partition are released. All gaze-agreement and faithfulness results are reported on the 200 test images, which were never used for training, model selection or the construction of any reference map.
Because patient identifiers are unavailable, all 1000 images were screened for exact and near-duplicates. Candidate pairs were found with a 64-bit discrete-cosine-transform perceptual hash (Hamming distance ≤ 10; 964 pairs) and verified by the Pearson correlation of the 192 × 192 greyscale images. Four pairs exceeded r = 0.95 (r = 0.978–1.000; the next pair had r = 0.948). Two of these involved a test image paired with a training image (no test–test pairs). All principal contrasts were repeated with these two test images excluded.
3.4. Segmentation Model
A compact four-level U-Net [45] (base width 16 channels, batch normalisation, 1,942,577 parameters) was trained from random initialisation. Inputs were standardised per channel with the mean and standard deviation of all pixels of the 700 training images (in 0–255 units: mean 142.9, 82.6 and 60.6; SD 80.8, 56.1 and 47.4 for red, green and blue). Training used AdamW (peak learning rate 2 × 10−3, weight decay 10−4, one-cycle schedule), batch size 8, 50 epochs and a loss equal to binary cross-entropy plus soft Dice. Augmentation comprised random horizontal and vertical flips, 90° rotations, and brightness and contrast jitter. The checkpoint with the highest validation Dice was retained. Three networks were trained with different random seeds (0, 1, 2) on the same split. No pretrained weights were used.
3.5. Explanation Target and Attribution Methods
Attribution methods explain a scalar, while a segmentation network outputs a map. Following Seg-Grad-CAM [34], the explained scalar was the sum of the output logits over a target region T: the pixels the model labels as polyp on the unperturbed image (logit > 0), or, if fewer than 10 pixels were predicted, the 5% of pixels with the highest logits. This fallback was needed for 2, 1 and 3 of the 200 test images for networks 0, 1 and 2. T was computed once from the original image and then held fixed for every interpolated, noisy, occluded, perturbed or randomised input, so each method explains the same scalar function of the input.
All methods were implemented directly in PyTorch (no attribution library) and run on the frozen network in evaluation mode. Seven methods were compared:
- Grad-CAM (bottleneck) [33,34]: channel weights equal to the spatially averaged gradient of the target with respect to the output of the bottleneck block (module `bott`, 256 channels, 12 × 12); map = ReLU of the weighted channel sum, upsampled bilinearly to 192 × 192.
- Grad-CAM++ (bottleneck) [46]: the same layer with Grad-CAM++ weights (closed-form second- and third-order gradient approximation, positive gradients only), followed by ReLU.
- Grad-CAM (decoder): Grad-CAM at the output of the second decoder block after the bottleneck (module `d3`, 64 channels, 48 × 48). Counting from the bottleneck, the decoder blocks operate at 24, 48, 96 and 192 pixels, so this is the second of four.
- Vanilla gradient [47]: absolute input gradient, summed over the three colour channels.
- Integrated Gradients [48]: 32-step right Riemann sum from a baseline of zero in standardised units, which is the spatially constant image with the training channel means (RGB 142.9, 82.6, 60.6); absolute attribution summed over channels.
- GradientSHAP [49,50]: the expected-gradients estimator as defined in Captum [50], with 32 samples; each sample draws a baseline from N(0, 0.52) independently per pixel and channel (standardised units) and an interpolation coefficient from U(0, 1), and averages gradient × (input − baseline). Absolute attribution was summed over channels. The random generator was seeded (PyTorch seed 0) for each network.
- Occlusion [51]: 32 × 32 patches with stride 16 set to the baseline value; the drop in the target was averaged over overlapping patches and passed through ReLU.
Sign handling therefore differs by family: class-activation and occlusion maps keep positive evidence, whereas the three gradient-based maps use magnitudes, as is common for visualisation. Because this choice could favour one family, the analysis was repeated with positive-only and absolute-of-sum variants of the gradient-based methods (Section 3.11).
3.6. Gaze Maps and Reference Maps
For each image, a binary fixation map marked every pixel that received at least one fixation, and a fixation density map was obtained by adding a unit impulse for every fixation (so repeated fixations on the same pixel add up), convolving with an isotropic Gaussian (σ = 3% of image width, 5.76 pixels at 192 pixels; reflected boundary) and normalising to unit sum. Under the reported geometry (Section 3.2), σ = 3% corresponds to 1.02–1.22° of visual angle, close to the one-degree kernel conventional in saliency evaluation, which approximates the extent of foveal vision and exceeds the 0.5° tracking error [38,39]. Kernel widths of 2% (0.68–0.81°) and 5% (1.70–2.03°) and duration-weighted densities [52] were tested as sensitivity analyses. All analyses ran at 192 × 192 pixels, whereas the annotator viewed the images at 768 × 768 pixels.
Six reference maps bracket the XAI scores:
- Chance: uniform noise smoothed with the gaze kernel. Two quantities are reported: in the agreement and faithfulness tables, one realisation (one random map per test image) with a 95% bootstrap confidence interval over test images, as for the other maps; and in the text, the mean and range of the whole-image CC over 20 independent realisations, which shows the variation between realisations. It is a baseline, not a guaranteed lower bound.
- Empirical gaze prior: the mean fixation density over the 700 training images. It captures the dataset’s central bias and its typical lesion locations [40].
- Geometric centre: an isotropic Gaussian at the image centre with SD equal to the mean SD of all training fixation coordinates (37.3 pixels), which captures centre bias without lesion information.
- Model output: the predicted polyp probability map, which tests whether an explanation agrees with gaze better than the prediction it explains.
- Lesion mask: the ground-truth mask smoothed with the gaze kernel, an oracle for lesion localisation.
- Boundary distance: inside the lesion, the Euclidean distance to the lesion boundary normalised to the range 0–1 per lesion (zero outside), smoothed with the gaze kernel; a geometry-only map that favours the lesion interior.
Attribution maps have very different native smoothness: gradient maps vary from pixel to pixel, whereas Grad-CAM maps are upsampled from 12 × 12 or 48 × 48 grids, and the gaze density is smoothed by construction. Every comparison was therefore made twice: with the raw maps and with resolution-matched maps in which each attribution map and the model output were smoothed with the same Gaussian kernel as the gaze density. Both are reported; conclusions are drawn only where they agree or where the difference is itself the finding.
3.7. Gaze-Agreement Metrics
Let S be a map, G the fixation density and F the binary fixation map over the N = 1922 pixels. Five standard metrics [39] were used, implemented as follows (code released):
- CC: the Pearson correlation between S and G over all pixels.
- NSS: the mean of the z-scored map, (S − mean S)/SD S, over pixels with F = 1.
- AUC-Judd: the area under the ROC curve that separates fixated pixels (F = 1) from all pixels, thresholding at each fixated-pixel value of the min–max-normalised map; ties were broken by adding uniform jitter of amplitude 10−7.
- SIM: the sum over pixels of min(P, Q), where P = S+/ΣS+, Q = G/ΣG and S+ is S with negative values set to zero.
- KL: KL(Q‖P) = Σ Q log(ε + Q/(P + ε)), with ε = 10−12, so that the divergence is measured from gaze to map, as in [39].
Higher is better for all except KL. No map was constant over the whole image. Two mask-based metrics were added for comparison with conventional evaluation: the fraction of non-negative attribution inside the lesion mask (energy), and the pointing game (whether the map’s maximum lies inside the mask). The pointing hit was computed per network and image, averaged over the three networks for each image, and then averaged over images.
CC was designated the primary metric before the revision analyses; the others are reported for completeness.
3.8. Within-Lesion and Geometry-Controlled Agreement
Whole-image agreement mixes two things: whether a map highlights the lesion and how it distributes its values inside the lesion. Two levels of analysis are therefore reported rather than a formal decomposition. Within-lesion CC and NSS were computed only over pixels inside the ground-truth mask. A map that is constant inside the lesion has undefined within-lesion correlation; such cases were set to missing and excluded from that comparison rather than replaced by zero. This occurred only for Grad-CAM (bottleneck), for 5 image–network combinations (4 after resolution matching), when the 12 × 12 map was zero over the whole lesion.
A map can also correlate with gaze inside the lesion simply because both are higher in the lesion interior. To test whether agreement exceeds what lesion geometry alone predicts, a geometry-controlled within-lesion correlation was computed: inside the lesion, both the map and the fixation density were regressed by least squares on a geometry basis consisting of an intercept, the normalised distance to the boundary d, d2 and d3, and the smoothed lesion mask, and the residuals were correlated. A simpler control using only linear distance to the boundary gave the same conclusions and is reported in Table S1.
3.9. Fixation-Order Groups
The annotation protocol had two instructed phases, locating and scanning, but phase boundaries were not recorded. Agreement was therefore compared for operationally defined fixation groups rather than cognitive stages: the first fixation versus all subsequent fixations (primary split); fixations before versus from the first fixation inside the lesion; and fixations 1–3 versus 4 onward (the split used in the original submission). NSS was computed for each group using the binary map of that group’s fixations.
3.10. Faithfulness: Deletion and Insertion
Pixels were ranked by the value of a map; ties were broken randomly by adding uniform jitter of negligible amplitude (10−9) before sorting, independently for each image and map. For deletion, the top-ranked fraction f of pixels was replaced by the baseline (training channel-mean) value; for insertion, the top-ranked pixels of the original image were pasted into a heavily blurred copy (Gaussian σ = 10 pixels). The main analysis used f = 0, 0.1, …, 1 for all 200 test images and three networks. At each step, the score was the mean predicted probability inside the fixed target region T, divided by its value on the original image:
where zf is the logit map of the perturbed image. Faithfulness was the area under s(f) (trapezoidal rule); lower deletion and higher insertion indicate a better ordering. Because the ratio is relative to the original image and probabilities can increase under perturbation, s is not bounded above by 1: an insertion area above 1 means that partially restored images gave the model more confidence in T than the original image did. Normalising by the original value puts images with high and low original confidence on the same scale, at the cost of amplifying changes for images with low original confidence. The same procedure was applied to annotator gaze (pixels ordered by fixation density), the lesion mask, the empirical gaze prior, the model output and the chance map, so that gaze and explanations were scored on one scale.
s(f) = mean_{T} σ(zf)/mean_{T} σ(z_0),
Three checks addressed choices that could drive the ranking (Section 3.11): an aligned score, an alternative replacement scheme and a finer early grid.
3.11. Robustness and Sanity Checks
These checks were added in revision and run on representative subsets to keep computation feasible on a CPU.
- Aligned score, alternative replacement and finer grid (100 randomly selected test images, network 0): the deletion and insertion curves were recomputed on a grid with 17 steps (0, 1, 2, 3, 5, 7.5, 10, 15, 20, 30, …, 100%) with two scores from the same forward passes: the original normalised probability and the summed logit over T, which is exactly the scalar the attribution maps explain. Two replacement schemes were compared: scheme A as above, and scheme B, in which deleted pixels were replaced by the blurred image and insertion started from the baseline image. Areas over the first 10% of pixels were also computed.
- Sign handling (200 test images, network 0): positive-only (ReLU of the channel-summed attribution) and absolute-of-sum variants of the three gradient-based methods.
- Convergence (40 test images, network 0): Integrated Gradients with 8–128 steps and GradientSHAP with 8–128 samples, each compared with a 128-step or 128-sample reference by Spearman correlation; GradientSHAP was also recomputed with three random seeds.
- Model-parameter randomisation (25 test images, network 0): following Adebayo et al. [7], the weights were re-initialised cumulatively from the output layer toward the input (head, then decoder blocks, bottleneck and encoder blocks). The target region T was kept fixed from the trained network, so each randomised network was explained with respect to the same pixels. The Spearman correlation between each map and its trained-network version, and the map’s whole-image CC with gaze, are reported.
- Image content inside the lesion (200 test images, three networks): to test whether gradient-based maps favour edges and specular highlights, the analysis computed inside the lesion the Spearman correlation of each map with the Sobel gradient magnitude of the luminance image, and the share of each map on specular highlights (HSV value > 0.9 and saturation < 0.2) and on a 3-pixel rim inside the lesion boundary, each divided by the corresponding area share (1 = proportional allocation).
3.12. Statistical Analysis
Per-image scores were averaged over the three networks, so each test image contributed one value per map and metric (the robustness subsets used network 0). Means are reported with 95% percentile bootstrap confidence intervals (2000 resamples of test images). These intervals quantify uncertainty over images for a single annotator; they do not quantify variability across observers, which these data cannot estimate.
The principal contrasts compared each XAI method with the model output, as paired per-image differences with bootstrap 95% CIs, the paired effect size dz (mean difference divided by the SD of differences), the proportion of images in which the method was higher, and two-sided Wilcoxon signed-rank tests. Holm correction was applied within each family of seven comparisons (one family per metric and variant: whole-image CC raw and matched, within-lesion CC raw and matched, geometry-controlled CC raw and matched, NSS). Friedman tests across the seven XAI methods were used as omnibus tests. For the fixation-group analysis, the early-versus-late contrast for each of the 11 maps formed a family. For faithfulness, gaze was compared with each other map (Holm over 11 comparisons per test). Associations with segmentation quality and lesion size used Spearman correlation and partial Spearman correlation adjusting for lesion area; significance was computed with the t-approximation, t = ρ√((n − 2 − k)/(1 − ρ2)) with k controlled variables. First-fixation and later-fixation durations were compared within images: for each image, the first fixation duration was paired with the mean duration of its later fixations, and the pairs were compared with the Wilcoxon signed-rank test (rank-biserial effect size). Non-significant differences are reported as such and not interpreted as equivalence. α = 0.05.
Analyses used Python 3.13.16, PyTorch 2.14.1 (CPU build), NumPy 2.5.3, SciPy 1.18.1, pandas 3.0.5, OpenCV 5.0.0 and Matplotlib 3.11.2 on a 2-core Intel Xeon CPU (2.10 GHz, one thread per core). Attribution maps were computed with two PyTorch threads; computation times are wall-clock means per test image, measured around each method call.
3.13. Ethics
This is a secondary analysis of two public, de-identified datasets released for research. No new data were collected from human participants, so institutional review board approval and informed consent were not required.
3.14. Use of Generative AI
Generative AI (Claude Opus 5.5; Anthropic, San Francisco, CA, USA) was used under the author’s direction to assist with developing and executing the analysis code, generating the figures and language editing. All analyses were run on the public data described above; the author reviewed and revised all AI-assisted content, verified the code, results, statistics and references, and takes full responsibility for the content.
4. Results
4.1. The Eye-Movement Record
Across the 1000 images, the annotator made a median of 25 fixations per image (interquartile range [IQR] 20–33; total 26,832) with a median per-image mean fixation duration of 333 ms (IQR 307–368). Over each image’s whole fixation sequence, a median of 90% of fixations (IQR 79–96%) and 92% of dwell time (IQR 82–97%) fell inside the polyp mask. Fixation density alone discriminated polyp from background pixels almost perfectly (median AUC 0.984, IQR 0.970–0.992), and only one image had no fixation on the polyp.
The first fixation behaved differently from the rest (Figure 1). It landed on the polyp in 45% of images; it lay close to the image centre (median distance 9% of image width, versus 19% for polyp centroids), consistent with the central bias of early fixations [41,42], and it hit the polyp in 79% of images where the polyp covered the centre but in 15% of the rest. The second fixation was inside the polyp in 93% of images, and in every later fixation-order group 85–91% of fixations fell inside it, so gaze was concentrated on, but not confined to, the lesion. Within images, the first fixation was shorter than the mean of the later fixations (255 ms versus 350 ms; paired difference 95 ms, 95% CI 87–102 ms; Wilcoxon p < 10−96; rank-biserial r = 0.77; later fixations longer in 86% of images). The number of fixations grew with polyp size (Spearman ρ = 0.74 between polyp area and fixation count; ρ = 0.58 with total dwell time; n = 1000; both p < 10−90 by the t-approximation), consistent with the instruction to scan the whole polyp.
Figure 1.
Eye-movement profile over fixation order (all 1000 images). (a) Percentage of fixations falling inside the polyp mask. (b) Fixation duration. Bars show fixation-weighted means with 95% bootstrap confidence intervals (resampling images); diamonds show image-weighted means. Tick labels give the fixation-order group, the number of images contributing to it and the number of fixations; later groups include only images with sufficiently long sequences. Most fixations from the second onward fell inside the polyp, but 7–15% per group fell outside it.
These properties shape how gaze agreement should be read. Because gaze covers the lesion so completely, a map that simply highlights the polyp will agree well with gaze. Gaze can carry additional information only in how fixations are distributed within and immediately around the lesion, which is why within-lesion agreement is analysed and controlled for lesion geometry (Section 4.4).
4.2. Segmentation Performance
The three networks reached a best validation Dice of 0.851, 0.854 and 0.850 and a test Dice of 0.825, 0.832 and 0.831 (mean 0.829 ± 0.004). Thirteen of the 200 test images had a network-averaged Dice below 0.5; these are analysed as failure cases in Section 4.9. The networks predicted an empty mask for 2, 1 and 2 test images, respectively.
4.3. Whole-Image Agreement with Gaze
Grad-CAM at the decoder agreed best with gaze among the explanations, but no attribution method agreed with gaze better than the model’s own output (Table 1, Figure 2 and Figure 3a; mask-based metrics in Table 2). On raw maps, the seven methods differed strongly in CC (Friedman χ2(6) = 616.8, p < 10−100, n = 200). Grad-CAM (decoder) reached CC = 0.617 and exceeded every other XAI method (Holm-corrected Wilcoxon p < 10−9). Occlusion (0.563) and Grad-CAM at the bottleneck (0.560) followed, then Grad-CAM++ (0.487); the three gradient-based methods agreed the least (0.363–0.405). Every method exceeded the empirical gaze prior (0.311), the geometric centre (0.298) and chance (mean CC 0.000, range −0.009 to 0.009 over 20 independent realisations; the single realisation shown in Table 1 gave −0.003 [95% CI −0.014 to 0.009], within that range).
Table 1.
Whole-image agreement between each map and annotator gaze (200 test images, three networks averaged). Raw: maps as computed; matched: attribution maps and model output smoothed with the gaze kernel. CC is shown with 95% bootstrap confidence intervals. Higher is better except for KL. Reference maps without a model component are identical in both variants. In this table and in the agreement and faithfulness tables that follow, the chance row is a single realisation of the random map (one map per test image) and, like the other rows, its interval is a 95% bootstrap confidence interval over test images; the spread across 20 independent realisations (mean CC 0.000, range −0.009 to 0.009; Section 4.3) is a different quantity, the variation between realisations. Rows labelled Reference (in italics) are reference maps, not explanation methods.
Figure 2.
Examples from network 0 at the 90th, 50th and 10th percentiles of Grad-CAM (decoder) whole-image CC, and one image with good segmentation (Dice ≥ 0.90) but the lowest CC among such images. Row labels give the Kvasir-SEG image identifier (first nine characters), Dice and CC. Orange outline: ground-truth polyp. Column 2: fixation density with the fixation sequence; the yellow dot marks the first fixation and yellow arrows mark the first three saccades. Each map is min–max scaled to 0–1 separately (clipped at its 99.5th percentile) and shown on the common colour scale. In the last two rows, the annotator scanned the whole of a large polyp, whereas the model output covers it uniformly and the explanations concentrate on parts of it.
Figure 3.
Agreement of each map with annotator gaze. (a) Correlation with fixation density over the whole image. (b) Correlation over pixels inside the ground-truth polyp. (c) Within-lesion correlation after controlling for lesion geometry (XAI methods and model output only). Circles: raw maps; diamonds: maps smoothed with the gaze kernel. Blue: XAI methods; grey: reference maps; the dotted line in (a) marks chance. Points are means over 200 test images (three networks averaged); bars are 95% bootstrap confidence intervals.
Table 2.
Mask-based and within-lesion agreement (200 test images, three networks averaged; mean [95% CI]). Energy: fraction of non-negative attribution inside the lesion mask. Point: pointing-game hit rate. Within-lesion CC: correlation with fixation density over lesion pixels only. Geometry-controlled CC: within-lesion correlation after removing the part of both maps explained by lesion geometry (Section 3.8). n = 199 for Grad-CAM (bottleneck) within-lesion values (constant maps excluded). Chance row: a single realisation, with 95% bootstrap confidence intervals over test images (see Table 1). Rows labelled Reference (in italics) are reference maps, not explanation methods.
The model’s probability map reached CC = 0.640. The difference between Grad-CAM (decoder) and the model output was small in absolute terms (−0.023, 95% CI −0.032 to −0.013; dz = −0.33; Grad-CAM higher in 33% of images) but consistent enough to be statistically significant (Holm p = 5.7 × 10−7); all other methods were further below the model output (differences −0.077 to −0.277, dz −0.69 to −2.10; Table 3). Two geometry-only references also scored high: the smoothed lesion mask (0.743) and the boundary-distance map (0.663), which contain no information from the model.
Table 3.
Paired differences from the model output (XAI method minus model output; 200 test images, three networks averaged). Each cell gives the mean difference [95% bootstrap CI]; the paired effect size dz; and the Holm-corrected Wilcoxon p-value (Holm correction within each column). Positive values favour the XAI method. Raw: maps as computed; matched: maps smoothed with the gaze kernel; geometry-controlled: flexible geometry basis (Section 3.8).
Resolution matching raised every attribution method and changed the ranking moderately (Kendall τ = 0.71 between raw and matched rankings). The gradient-based methods gained the most (GradientSHAP 0.405 → 0.547; Integrated Gradients 0.369 → 0.521; vanilla gradient 0.363 → 0.496), so that GradientSHAP and Integrated Gradients overtook Grad-CAM++ (0.502). A substantial part of the raw differences between method families therefore reflects spatial resolution and smoothness rather than where the methods place their evidence. Grad-CAM (decoder) remained the highest method after matching (0.651; Holm p < 10−14 against each other method), and remained below the matched model output (0.674; difference −0.023, 95% CI −0.032 to −0.014). NSS and SIM broadly agreed with CC. On the pointing game, the class-activation methods hit the polyp in 94–98% of images versus 66–80% for gradient methods and occlusion. Grad-CAM variants had high KL divergence on raw maps (3.6–3.9) despite high CC because their maps are exactly zero over background areas that still received occasional fixations, a known sensitivity of KL to sparse maps [39]; matching reduced this to 1.4–1.8. Excluding the two test images with a near-duplicate in the training set changed no contrast by more than 0.002 (Table S2).
4.4. Agreement Inside the Lesion
Inside the lesion, the apparent advantage of class-activation methods was explained by smoothness and lesion geometry (Table 2, Figure 3b,c). On raw maps, the three Grad-CAM variants reached within-lesion CC of 0.194–0.195 and exceeded the model output (0.134; differences +0.060 to +0.061, Holm p ≤ 0.0018; Table 3). Occlusion was also positively associated with gaze inside the lesion (0.103, 95% CI 0.071–0.137) but slightly below the model output (−0.031, Holm p = 0.06), and the three gradient-based methods were slightly negatively correlated with gaze (−0.026 to −0.063).
This pattern did not survive resolution matching. When all maps were smoothed to the gaze kernel, the model output rose to 0.254 and exceeded every XAI method, including Grad-CAM (decoder) (0.224; difference −0.030, 95% CI −0.050 to −0.012, Holm p = 0.007). Two geometry-only maps did at least as well as any explanation: the smoothed lesion mask (0.311) and the boundary-distance map (0.225). Much of the within-lesion agreement therefore reflects a shared preference for the lesion interior that any smooth, lesion-shaped map reproduces.
After controlling for lesion geometry, residual within-lesion agreement was close to zero for every map (Table 2, Figure 3c): between −0.023 and 0.032 for raw maps and between −0.052 and 0.030 for resolution-matched maps. No method was significantly above zero after Holm correction, and none exceeded the model output; the largest differences, for the two bottleneck class-activation maps on raw maps (+0.047 and +0.050; Table 3), were small and not significant after correction (Holm p = 0.06). Integrated Gradients remained slightly negative. With a simpler control for linear distance to the boundary only (Table S1), Grad-CAM (decoder) retained a small positive association (0.071, 95% CI 0.039–0.105), but so did the model output (0.054) and, notably, the smoothed lesion mask (0.197), which carries no image information; a linear distance term therefore does not remove lesion geometry fully, and the flexible control is the appropriate test. Within the resolution of these data, no explanation showed statistically significant positive residual agreement with the annotator’s within-lesion fixations after the tested geometry controls. This does not show that lesion geometry fully explains within-lesion gaze: the controls use a finite geometry basis, and the tracking error limits the spatial detail that can be resolved. Excluding the two test images with near-duplicates did not change any of these contrasts (Table S2).
4.5. Agreement for Early and Later Fixation Groups
The first fixation and the subsequent fixations were matched by different maps (Table S3). The empirical gaze prior predicted the first fixation well (NSS = 3.42) and subsequent fixations poorly (0.88; Holm p < 10−32), and the geometric centre behaved similarly (2.52 versus 0.87). Every lesion-shaped map showed the opposite pattern: the lesion mask (0.86 versus 2.74), the model output (0.72 versus 2.40) and Grad-CAM (decoder) (0.75 versus 2.36) all predicted subsequent fixations much better than the first (all Holm p < 10−15). Splitting at the first fixation inside the lesion (118 test images had at least one fixation before lesion entry) gave the same pattern more sharply: before entry, lesion-shaped maps had NSS near or below zero (Grad-CAM decoder −0.23, model output −0.23, lesion mask −0.09), whereas the empirical gaze prior reached 3.29.
With the split used in the original submission (fixations 1–3 versus 4 onward), no significant difference was detected for Grad-CAM (decoder) (2.30 versus 2.29; Holm p = 1.0) or occlusion (1.91 versus 1.92; Holm p = 1.0), whereas the model output (2.06 versus 2.37; Holm p = 0.002) and lesion mask (2.27 versus 2.71; Holm p < 10−8) predicted the later group better. Because fixations 2 and 3 were already on the lesion in most images, this split dilutes the distinctive first fixation; the first-versus-subsequent contrast is the more informative one in these data.
4.6. Faithfulness of Explanations and of Annotator Gaze
The explanations most aligned with gaze were not the most faithful (Table 4, Figure 4). GradientSHAP had the best mean score on both tests (deletion 0.078, insertion 0.955). Integrated Gradients had the second-best insertion score (0.943), and on deletion its mean (0.087) was almost identical to that of Grad-CAM (bottleneck) (0.086); such small differences in numerical rank are not statistically supported orderings. The Grad-CAM variants ranked comparatively well on deletion (0.086–0.092) and lower on insertion (0.877–0.892, below the gradient-based methods and occlusion); how they compare with annotator gaze is examined per image below. Across the seven methods, the rank correlation between whole-image gaze agreement and faithfulness was weak and non-significant (Spearman ρ = −0.36 with insertion, p = 0.43; ρ = −0.04 with deletion, p = 0.94; n = 7); with seven observations, this cannot establish that the two properties are unrelated.
Table 4.
Faithfulness (deletion and insertion area under the normalised probability curve; mean [95% CI]; 200 test images, three networks). Lower deletion and higher insertion indicate a more faithful ordering. Values above 1 on insertion are possible because the score is a ratio to the original image (Section 3.10). Chance row: a single realisation, with 95% bootstrap confidence intervals over test images (see Table 1). Rows labelled Reference (in italics) are reference maps; annotator gaze (in bold) is the recorded gaze, used as a pixel ordering.
Figure 4.
Faithfulness of XAI maps (blue), annotator gaze (orange) and reference maps (grey), in the row order of Table 4. (a) Deletion and (b) insertion areas under the normalised probability curve, with mean values printed beside each interval. The dotted line in (b) marks 1; insertion values above 1 occur when partially restored images yield a higher probability than the original. Median deletion and insertion curves are shown in Figure S1.
When annotator gaze was used to order pixels, it was clearly more faithful than the empirical gaze prior and chance (Holm p < 10−11 on both tests). Paired comparisons with the XAI methods depended on the test. On insertion, no significant difference was detected between gaze (mean 0.895) and Grad-CAM (bottleneck) (p = 0.38); gaze was better than Grad-CAM++ (p < 10−5) and worse than the other five methods, the lesion mask and the model output (all Holm p < 10−4). The per-image results explain why the two Grad-CAM comparisons differ despite the ordering of the means. Grad-CAM (decoder) gave the higher insertion score in 61% of images (median paired difference +0.008), a small but consistent advantage, whereas the gaze mean (0.895) is raised by a few images in which inserting the most-fixated pixels gave scores far above 1 (two images above 1.2, maximum 4.9). Grad-CAM (bottleneck), in contrast, was higher than gaze in only 47% of images (median paired difference −0.001); its larger gap in means (0.877 versus 0.895) comes from the same few images, so the paired test detects no difference. On deletion, gaze was less faithful than five of the seven methods (Holm p ≤ 3 × 10−5), and no significant difference was detected against Grad-CAM++ (p = 0.45). Against vanilla gradient, the means favoured the gradient (0.123 versus 0.143), yet gaze had the lower deletion score in 63% of images (median paired difference 0.006 in favour of gaze; Holm p = 0.012). The two summaries answer different questions: the Wilcoxon test reflects how consistently gaze was better, whereas the mean and the wide confidence interval of gaze (0.101–0.221) are dominated by a minority of images in which deleting the most-fixated pixels failed to remove the model’s evidence.
4.7. Robustness of the Faithfulness Ranking
On the 100-image subset (network 0), the finer grid reproduced the original ordering closely (Kendall τ = 0.79 with the original-grid ranking of the eight orderings, for both deletion and insertion; Table S4). The ranking was less stable across scoring and replacement choices: the aligned score (summed logit over T) gave τ = 0.36 for deletion and 0.50 for insertion; the alternative replacement scheme with the probability score gave 0.57 and 0.71; and changing both gave 0.43 and 0.07. Most differences between methods arose within the first 10–20% of perturbed pixels (Figure S1). Some results held across all 16 combinations of test, score, scheme and curve range (full area or first 10%): GradientSHAP ranked among the three most faithful of the eight orderings (seven methods and gaze) in 15 of 16 combinations and Integrated Gradients in 11; vanilla gradient ranked last or second last in all eight deletion combinations; and annotator gaze never ranked above fifth. Others did not: occlusion was the first- or second-most faithful ordering for deletion under the aligned score or scheme B but ranked sixth to eighth for early insertion, and the class-activation methods moved between first and eighth place. These summaries use mean per-image ranks, because the logit ratio becomes large and negative for some images once deletion pushes logits below zero. Repeating random tie-breaking with five seeds (20 images) changed method means by at most 0.004.
4.8. Sanity, Convergence and Sign-Handling Checks
Model-parameter randomisation separated the method families sharply (Table S5a). The maps of Grad-CAM (bottleneck and decoder) and occlusion changed as soon as the output layer was re-initialised (Spearman ρ with the trained-network map −0.70 to −0.50 after randomising the head alone) and, after full randomisation, were unrelated to the trained maps (|ρ| ≤ 0.13) and to gaze (CC −0.06 to −0.03). Grad-CAM++ was less sensitive and retained a gaze CC of 0.22 after full randomisation. The three gradient-based maps, by contrast, remained highly similar to their trained-network versions throughout the cascade (ρ = 0.87–0.88 after all layers were re-initialised), and their gaze agreement did not fall (CC 0.39–0.41 for the trained network versus 0.50–0.62 after full randomisation). Because the explained scalar sums the logits over a fixed target region that lies on the lesion, gradient maps of even a random network concentrate around that region; their gaze agreement therefore largely reflects where the target region lies rather than what the network has learned. This failure of the sanity check [7] is a further reason not to read the gaze agreement of gradient-based maps as evidence about the model.
Integrated Gradients had converged at 32 steps (ρ = 0.997 with a 128-step map; Table S5b). GradientSHAP maps were noisier pixel by pixel (ρ = 0.86 with a 128-sample map, and 0.83 between 32-sample maps computed with different seeds), but their gaze agreement varied by at most 0.01 across sample counts, and the per-image SD of CC across seeds had a median of 0.015. Positive-only attributions for the gradient-based methods lowered raw CC (0.24–0.25 versus 0.38–0.40 on network 0) but left resolution-matched CC (0.52–0.54) and within-lesion CC essentially unchanged, and the gradient-based methods remained below Grad-CAM (decoder and bottleneck) and occlusion in every variant (Table S5c).
4.9. Where Inside the Lesion the Maps Concentrate
The image-content analysis supported part of the explanation proposed in the original submission for the within-lesion differences (Table S6). Inside the lesion, annotator gaze was allocated less than proportionally to the 3-pixel rim (rim share ratio, median 0.64), a pattern that is at least partly a consequence of the instruction to scan from the centre toward the boundary, and close to proportionally to specular highlights (1.09; 188 of 200 lesions contained highlight pixels). Integrated Gradients and GradientSHAP over-weighted specular highlights 2.6- and 3.4-fold (medians; both Holm p < 10−26 against gaze) and did not favour the interior over the rim (rim ratios 1.10 and 0.92), and Integrated Gradients was weakly positively correlated with local edge strength (median ρ = 0.07), whereas gaze was weakly negatively correlated with it (ρ = −0.08). Vanilla gradient also lacked an interior preference (rim ratio 1.06) but under-weighted highlights (0.38), so the highlight explanation does not apply to it. The Grad-CAM variants placed even less weight on the rim than gaze (0.32–0.54) and over-weighted highlights modestly (1.15–1.56). Thus, gradient-based maps differ from gaze mainly by lacking the interior emphasis, and two of them also by emphasising specular highlights; these associations are descriptive and do not show what the network uses.
4.10. Agreement and Segmentation Quality
Explanations agreed more with gaze on images the model segmented well. Per-image whole-image CC correlated positively with Dice for every XAI method (Spearman ρ = 0.32–0.50, all p < 10−5), and the association was unchanged after adjusting for polyp area (partial ρ = 0.33–0.52). In the 13 failure cases (Dice < 0.5), Grad-CAM (decoder) agreement fell from 0.64 to 0.26 (Mann–Whitney p < 10−7), with similar drops for all methods. Whole-image agreement also decreased with polyp size (ρ = −0.49 to −0.66), reflecting large polyps that the annotator scanned with fixations spread over the lesion, whereas the maps covered it densely (Figure 2, last two rows). Within-lesion CC, by contrast, was unrelated to Dice (|ρ| ≤ 0.07, p ≥ 0.32). Figure 2 (last row) shows that low agreement can occur despite accurate segmentation.
4.11. Sensitivity and Run-to-Run Stability
The ranking of maps by CC was stable to the gaze kernel width (Kendall τ = 0.96 for σ = 2% and 1.00 for σ = 5% of image width) and to duration weighting (τ = 1.00); resolution matching changed it moderately (τ = 0.71; Section 4.3). Across the three networks, the standard deviation of method-level mean CC was at most 0.021, and Grad-CAM (decoder) ranked first and vanilla gradient last among the XAI methods for every network; the only change in order was a swap between occlusion and Grad-CAM (bottleneck), whose means differ by less than 0.03 (Table S7). Mean computation time per test image (two threads; Section 3.12) was 0.05 s for the Grad-CAM variants, 0.07 s for vanilla gradient, 2.0 s for Integrated Gradients, 2.9 s for GradientSHAP and 4.7 s for occlusion.
5. Discussion
5.1. Principal Findings
This exploratory study compared explanations of a polyp segmentation model with the recorded gaze of one annotator. Three findings stand out.
First, whole-image gaze agreement in this task is mostly a matter of lesion localisation. Grad-CAM at a decoder layer agreed best with gaze among the explanations, but the model’s own probability map agreed slightly better, with or without resolution matching. The absolute gap was small (about 0.02 in CC), so the more important point is not that the explanation was worse but that it was not better: a map that highlights what the model segments will look right against gaze, whether or not it explains anything. Geometry-only maps, such as the smoothed lesion mask and the boundary-distance map, scored higher still. When an explanation is claimed to agree with human attention, the model output and a lesion-shaped baseline are needed to show that the agreement goes beyond the prediction itself.
Second, after the tested geometry controls, the within-lesion analysis found no statistically significant positive residual agreement between any explanation and how the annotator distributed fixations inside the polyp; this is an absence of evidence, not a demonstration that lesion geometry fully explains within-lesion gaze. The original submission interpreted the higher raw within-lesion correlation of the Grad-CAM variants as evidence that they reproduced the annotator’s emphasis on the polyp interior. The revision analyses do not support that interpretation: the advantage reversed when all maps were smoothed to the gaze resolution, a geometry-only map matched the best explanation, and after flexible control for lesion geometry no method retained more than a negligible association with gaze (|CC| ≤ 0.05) or exceeded the model output. The annotator’s fixations favoured the polyp interior over its rim (Section 4.9), but the protocol instructed the annotator to scan from the polyp’s centre toward its boundary, so this pattern is at least partly produced by the instruction rather than being a spontaneous property of expert inspection. The descriptive finding appears to hold for these data, but it should not be generalised to free viewing; and any smooth map that is higher in the interior, including the model output, shares the preference. Gradient-based maps lacked the interior preference, and two of them over-weighted specular highlights (Section 4.9), which is consistent with their slightly negative raw within-lesion correlation, but this is a description of the maps rather than evidence about the features either the network or the annotator used.
Third, gaze agreement and faithfulness ranked the methods differently. GradientSHAP and Integrated Gradients were the most faithful methods by deletion and insertion, yet among the least aligned with gaze. With only seven methods, the non-significant method-level rank correlation between the two properties (ρ = −0.36 with insertion, p = 0.43) is weak evidence either way and does not show that they are unrelated; the observation is the ranking difference itself, which agrees with the view that the two properties must be measured separately [5,7,8,53]. The faithfulness ranking was itself sensitive to how the test was set up: aligning the score with the explained target or changing the replacement scheme reordered several methods, especially occlusion and the class-activation maps, whereas GradientSHAP and Integrated Gradients remained among the most faithful in most configurations. Rankings from a single perturbation protocol should therefore be read as protocol-specific. The randomisation check adds a further caution: the gradient-based maps barely changed when the network’s weights were randomised, so part of their deletion–insertion advantage may come from concentrating on the target region rather than from model-specific evidence. Annotator gaze, used to order pixels, was a moderately faithful explanation of the network: its insertion score was close to those of the Grad-CAM variants, but deleting the most-fixated pixels removed the model’s evidence less reliably than most XAI orderings, failing badly on a minority of images. Spatial overlap and perturbation sensitivity do not, however, establish which visual features the annotator used to reach a judgement.
5.2. Relation to Previous Work
These results agree with chest radiography benchmarks in which saliency maps fell short of radiologist localisation and in which method rankings depended on the evaluation metric [9,10], and with the finding of Bigolin Lanfredi et al. that saliency maps agree with radiologists’ gaze less well than radiologists agree with one another [18]. They also echo the partial overlap between class activation maps and eye-movement heat maps reported for design evaluation [28]. Beyond that work, the present study shows for a segmentation task that a model-output baseline, resolution matching and a geometry control can each change the interpretation of gaze agreement: without them, the within-lesion results would have suggested that class-activation maps capture the annotator’s emphasis. Grad-CAM at a finer decoder layer outperformed the conventional bottleneck layer, consistent with the observation that coarse class-activation maps blur small structures [34].
For eye-movement research, the study shows that the interpretation of gaze agreement depends on the recording protocol. GazeMedSeg’s gaze was task-directed: the annotator was instructed to find and then cover a polyp known to be present. The resulting fixation densities discriminated lesion from background almost perfectly and behaved partly like a soft segmentation. Free diagnostic viewing, as in the chest radiography datasets [24,25] or clinical colonoscopy [13], would include search, rejection of distractors, and dwell on ambiguous regions, and might separate explanation methods more sharply; whether it does is an empirical question these data cannot answer.
The fixation-group analysis makes the same point at a finer grain. The first fixation, which started near the image centre and preceded lesion entry in more than half of the images, was predicted by centre-biased maps; subsequent fixations were predicted by lesion-shaped maps. Pooling all fixations, as standard saliency metrics do, mixes fixations that different maps predict in opposite ways. Where phase boundaries can be estimated, methods that segment scanpaths into phases, developed for reading [54], could make such phase-aware evaluation routine. These are described as fixation groups rather than verified cognitive stages, because phase boundaries were not recorded and 93% of second fixations were already on the lesion.
5.3. Practical Recommendations
For researchers who evaluate explanations of segmentation models against eye-tracking data, these results suggest the following practices:
- Report the model output, a lesion-shaped geometry-only map, an empirical gaze prior and chance alongside the explanations; an explanation that does not exceed the model output does not show agreement with gaze beyond that of the prediction, although it may still be useful for other purposes such as auditing.
- Compare maps at matched spatial resolution, or report both raw and matched results, because smoothness alone changes agreement.
- Report whole-image and within-lesion agreement separately, and control within-lesion agreement for lesion geometry before attributing it to the explanation method.
- Report faithfulness alongside gaze agreement, with the scored quantity aligned to the explained target and at least one alternative perturbation scheme.
- Analyse the first fixation (or fixations before lesion entry) separately when the protocol involves locating a target.
- Report the gaze kernel, duration weighting and their sensitivity, and the acquisition details available for the gaze data.
These recommendations come from one annotator, one architecture and still images that all contain a polyp. They are not recommendations about which method clinicians should see: there was no reader study. Within the tested setting, decoder-level Grad-CAM had the highest gaze agreement among the explanations at negligible cost (0.05 s per image on a CPU), and GradientSHAP and Integrated Gradients were the most consistently faithful across the perturbation protocols tested but failed the model-randomisation check, whereas Grad-CAM passed it; none of these observations should be generalised beyond this model and these tests.
5.4. Limitations
Several limitations qualify these conclusions.
- Single annotator with unspecified clinical expertise. The gaze comes from one annotator described as experienced in medical imaging; no endoscopy speciality is reported. Inter-observer variability could not be estimated, so agreement cannot be expressed relative to a human ceiling, and confidence intervals reflect variation over images only.
- Task-directed gaze. The annotator was instructed to locate and then exhaustively scan a polyp known to be present, so gaze reflects lesion inspection rather than search. The results do not describe clinical colonoscopy, where endoscopists search moving video for lesions that may be absent, and they do not show whether any map improves clinical decisions.
- Undocumented acquisition details and spatial precision. Calibration validation, drift correction, the fixation-detection algorithm, the instruction text and vision screening are not reported for the dataset. The reported tracking error (≤ 0.5°, about 1.2–1.5% of image width) limits how finely within-lesion fixation patterns can be resolved, which is a further reason not to over-interpret small within-lesion differences.
- Every image contains a polyp. Explanations of false-positive detections and of polyp-free frames could not be studied.
- Split without patient identifiers. Images of the same patient or polyp may occur across partitions, whereas patient-grouped splits are needed to rule out leakage [55]. The duplicate screen found two test images with near-identical training images, and excluding them did not change the results, but non-identical images of the same polyp cannot be detected this way. Such dependence could inflate segmentation performance and, by making test images less independent, narrow the image-level confidence intervals.
- One architecture and resolution. The networks were compact U-Nets trained from scratch on a CPU at 192 × 192 pixels, with anisotropic resizing. Larger, pretrained models at full resolution might produce different explanations; the three networks differed only in their random seed.
- Perturbation-based faithfulness. Deletion and insertion create out-of-distribution inputs [36]; one alternative scheme and an aligned score were tested on a subset, not all possible schemes.
- Gaze agreement is a proxy. It measures spatial correspondence with fixations, not whether an explanation is understandable or trusted.
- Prostate MRI not analysed. GazeMedSeg also provides gaze for prostate MRI slices, which were not analysed.
5.5. Future Work
The most valuable next step is gaze recorded during free viewing of colonoscopy frames, and ideally video, by several gastroenterologists, which would allow agreement to be referenced to inter-observer agreement and to include frames without polyps. Extending the analysis to the prostate MRI part of GazeMedSeg and to pretrained segmentation backbones would test generality. A reader study measuring whether explanations with high gaze agreement change endoscopists’ trust and decisions would connect these proxy measures to clinical value.
6. Conclusions
In this exploratory benchmark, the gaze of a single annotator who located and then scanned polyps in still colonoscopy images was compared with seven explanations of a polyp segmentation network. Over the whole image, Grad-CAM computed at a decoder layer agreed best with gaze among the explanations, but the model’s own probability map agreed slightly better, so whole-image agreement mainly reflected lesion localisation. Inside the lesion, raw class-activation maps exceeded the model output, but this advantage did not survive resolution matching or control for lesion geometry, and no explanation showed statistically significant positive residual agreement with the annotator’s within-lesion fixations after the tested geometry controls, although this does not establish that lesion geometry fully explains within-lesion gaze. The most faithful explanations by deletion and insertion were among the least aligned with gaze; the faithfulness ranking depended on the perturbation protocol, and the gradient-based maps failed a model-randomisation check that Grad-CAM and occlusion passed. Gaze-based evaluation of segmentation explanations is therefore most informative when it includes the model output and geometry-only baselines, compares maps at matched resolution, separates whole-image from geometry-controlled within-lesion agreement, and is reported together with faithfulness. Confirming these findings requires gaze from multiple endoscopists, free viewing and other architectures.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/jemr19060132/s1, Figure S1: Median deletion and insertion curves; Table S1: Within-lesion agreement controlled for linear distance to the boundary; Table S2: Principal contrasts with near-duplicate test images excluded; Table S3: Agreement for fixation-order groups; Table S4: Robustness of the faithfulness ranking; Table S5: Model-parameter randomisation, convergence and sign-handling checks; Table S6: Image content inside the lesion; Table S7: Per-network results.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
Kvasir-SEG is available from Simula Research Laboratory (https://datasets.simula.no/kvasir-seg/, accessed on 10 November 2026). GazeMedSeg fixation data are available via https://github.com/med-air/GazeMedSeg (accessed on 10 November 2026). Analysis code, split files, trained network weights, the software environment and per-image results are available at https://doi.org/10.5281/zenodo.23736003.
Acknowledgments
During the preparation of this manuscript, the author used Claude Opus 5.5 (Anthropic, San Francisco, CA, USA) to assist with developing and executing analysis code, generating figures, and language editing. The author subsequently reviewed and revised all AI-assisted content, verified the analyses and outputs, and takes full responsibility for the content of the publication.
Conflicts of Interest
The author declares no conflicts of interest.
References
- Zhao, S.; Wang, S.; Pan, P.; Xia, T.; Chang, X.; Yang, X.; Guo, L.; Meng, Q.; Yang, F.; Qian, W.; et al. Magnitude, risk factors, and factors associated with adenoma miss rate of tandem colonoscopy: A systematic review and meta-analysis. Gastroenterology 2019, 156, 1661–1674.e11. [Google Scholar] [CrossRef] [Scilit]
- Ullah, N.; Javed, A.; Alhazmi, A.; Hasnain, S.M.; Tahir, A.; Ashraf, R. TumorDetNet: A unified deep learning model for brain tumor detection and classification. PLoS ONE 2023, 18, e0291200. [Google Scholar] [CrossRef] [Scilit]
- Maswadi, K.; Alhazmi, A. Towards sustainable health management in the Kingdom of Saudi Arabia: The role of artificial intelligence—A systematic review, challenges, and future directions. Sustainability 2026, 18, 905. [Google Scholar] [CrossRef] [Scilit]
- Tjoa, E.; Guan, C. A survey on explainable artificial intelligence (XAI): Toward medical XAI. IEEE Trans. Neural Netw. Learn. Syst. 2021, 32, 4793–4813. [Google Scholar] [CrossRef] [Scilit]
- Jacovi, A.; Goldberg, Y. Towards faithfully interpretable NLP systems: How should we define and evaluate faithfulness? In Proceedings of the 58th Annual Meeting of the Association for Computational Linguistics; Association for Computational Linguistics: Stroudsburg, PA, USA, 2020; pp. 4198–4205. [Google Scholar]
- Doshi-Velez, F.; Kim, B. Towards a rigorous science of interpretable machine learning. arXiv 2017, arXiv:1702.08608. [Google Scholar]
- Adebayo, J.; Gilmer, J.; Muelly, M.; Goodfellow, I.; Hardt, M.; Kim, B. Sanity checks for saliency maps. In Proceedings of the Advances in Neural Information Processing Systems 31, Montréal, QC, Canada, 2–8 December 2018. [Google Scholar]
- Alhazmi, A. Explainable AI in medical imaging and diagnosis: A critical review of methods, clinical translation barriers, and an integrated evaluation framework. AI Clin. Med. 2026, 2, e36. [Google Scholar] [CrossRef] [Scilit]
- Saporta, A.; Gui, X.; Agrawal, A.; Pareek, A.; Truong, S.Q.H.; Nguyen, C.D.T.; Ngo, V.-D.; Seekins, J.; Blankenberg, F.G.; Ng, A.Y.; et al. Benchmarking saliency methods for chest X-ray interpretation. Nat. Mach. Intell. 2022, 4, 867–878. [Google Scholar] [CrossRef] [Scilit]
- Arun, N.; Gaw, N.; Singh, P.; Chang, K.; Aggarwal, M.; Chen, B.; Hoebel, K.; Gupta, S.; Patel, J.; Gidwani, M.; et al. Assessing the trustworthiness of saliency maps for localizing abnormalities in medical imaging. Radiol. Artif. Intell. 2021, 3, e200267. [Google Scholar] [CrossRef] [Scilit]
- Brunyé, T.T.; Drew, T.; Weaver, D.L.; Elmore, J.G. A review of eye tracking for understanding and improving diagnostic interpretation. Cogn. Res. Princ. Implic. 2019, 4, 7. [Google Scholar] [CrossRef] [Scilit]
- van der Gijp, A.; Ravesloot, C.J.; Jarodzka, H.; van der Schaaf, M.F.; van der Schaaf, I.C.; van Schaik, J.P.J.; Cate, T.J.T. How visual search relates to visual diagnostic performance: A narrative systematic review of eye-tracking research in radiology. Adv. Health Sci. Educ. 2017, 22, 765–787. [Google Scholar] [CrossRef] [Scilit]
- Lami, M.; Singh, H.; Dilley, J.H.; Ashraf, H.; Edmondon, M.; Orihuela-Espina, F.; Hoare, J.; Darzi, A.; Sodergren, M.H. Gaze patterns hold key to unlocking successful search strategies and increasing polyp detection rate in colonoscopy. Endoscopy 2018, 50, 701–707. [Google Scholar] [CrossRef] [Scilit]
- Liu, X.; Zheng, B.; Duan, X.; He, W.; Li, Y.; Zhao, J.; Zhao, C.; Wang, L. Detecting performance difficulty of learners in colonoscopy: Evidence from eye-tracking. J. Eye Mov. Res. 2021, 14, 1–13. [Google Scholar] [CrossRef] [Scilit]
- Moradizeyveh, S.; Tabassum, M.; Liu, S.; Newport, R.A.; Beheshti, A.; Di Ieva, A. When eye-tracking meets machine learning: A systematic review on applications in medical image analysis. arXiv 2024, arXiv:2403.07834. [Google Scholar]
- Zhong, Y.; Tang, C.; Yang, Y.; Qi, R.; Zhou, K.; Gong, Y.; Heng, P.A.; Hsiao, J.H.; Dou, Q. Weakly-supervised medical image segmentation with gaze annotations. In Medical Image Computing and Computer Assisted Intervention—MICCAI 2024; Springer: Cham, Switzerland, 2024. [Google Scholar]
- Jha, D.; Smedsrud, P.H.; Riegler, M.A.; Halvorsen, P.; de Lange, T.; Johansen, D.; Johansen, H.D. Kvasir-SEG: A segmented polyp dataset. In MultiMedia Modeling (MMM 2020); Springer: Cham, Switzerland, 2020; pp. 451–462. [Google Scholar]
- Bigolin Lanfredi, R.; Arora, A.; Drew, T.; Schroeder, J.D.; Tasdizen, T. Comparing radiologists’ gaze and saliency maps generated by interpretability methods for chest x-rays. In Proceedings of the NeurIPS 2022 Workshop on Gaze Meets Machine Learning, New Orleans, LA, USA, 28–29 December 2022. [Google Scholar] [CrossRef] [Scilit]
- Kundel, H.L.; Nodine, C.F.; Carmody, D. Visual scanning, pattern recognition and decision-making in pulmonary nodule detection. Invest. Radiol. 1978, 13, 175–181. [Google Scholar] [CrossRef] [Scilit]
- Lévêque, L.; Bosmans, H.; Cockmartin, L.; Liu, H. State of the art: Eye-tracking studies in medical imaging. IEEE Access 2018, 6, 37023–37034. [Google Scholar] [CrossRef] [Scilit]
- Kumari, P.; Azemi, G.; Russo, C.; Di Ieva, A. Characterizing visual neurosurgical expertise in brain MRI visualization using eye-tracking and 3D fractal dimension analysis. J. Eye Mov. Res. 2026, 19, 62. [Google Scholar] [CrossRef] [Scilit]
- Davies, A.R.; Vigo, M.; Harper, S.; Jay, C. Using simultaneous scanpath visualization to investigate the influence of visual behaviour on medical image interpretation. J. Eye Mov. Res. 2018, 10, 1–11. [Google Scholar] [CrossRef] [Scilit]
- Masud, U.; Almolhis, N.A.; Alhazmi, A.; Ramakrishnan, J.; Ul Islam, F.; Farooqi, A.R. Smart wheelchair controlled through a vision-based autonomous system. IEEE Access 2024, 12, 65099–65116. [Google Scholar] [CrossRef] [Scilit]
- Karargyris, A.; Kashyap, S.; Lourentzou, I.; Wu, J.T.; Sharma, A.; Tong, M.; Abedin, S.; Beymer, D.; Mukherjee, V.; Krupinski, E.A.; et al. Creation and validation of a chest X-ray dataset with eye-tracking and report dictation for AI development. Sci. Data 2021, 8, 92. [Google Scholar] [CrossRef] [Scilit]
- Bigolin Lanfredi, R.; Zhang, M.; Auffermann, W.F.; Chan, J.; Duong, P.-A.T.; Srikumar, V.; Drew, T.; Schroeder, J.D.; Tasdizen, T. REFLACX, a dataset of reports and eye-tracking data for localization of abnormalities in chest x-rays. Sci. Data 2022, 9, 350. [Google Scholar] [CrossRef] [Scilit]
- Saab, K.; Hooper, S.M.; Sohoni, N.S.; Parmar, J.; Pogatchnik, B.; Wu, S.; Dunnmon, J.A.; Zhang, H.R.; Rubin, D.; Ré, C. Observational supervision for medical image classification using gaze data. In Medical Image Computing and Computer Assisted Intervention—MICCAI 2021; Springer: Cham, Switzerland, 2021. [Google Scholar]
- Wang, S.; Ouyang, X.; Liu, T.; Wang, Q.; Shen, D. Follow my eye: Using gaze to supervise computer-aided diagnosis. IEEE Trans. Med. Imaging 2022, 41, 1688–1698. [Google Scholar] [CrossRef] [Scilit]
- Jia, J.; Zhao, T.; Yang, J.; Wang, Q. Intelligent evaluation method for design education and comparison research between visualizing heat-maps of class activation and eye-movement. J. Eye Mov. Res. 2024, 17, 1–34. [Google Scholar] [CrossRef] [Scilit]
- Šola, H.M.; Qureshi, F.H.; Khawaja, S. AI eye-tracking technology: A new era in managing cognitive loads for online learners. Educ. Sci. 2024, 14, 933. [Google Scholar] [CrossRef] [Scilit]
- Šola, H.M.; Qureshi, F.H.; Khawaja, S. Predicting behaviour patterns in online and PDF magazines with AI eye-tracking. Behav. Sci. 2024, 14, 677. [Google Scholar] [CrossRef] [Scilit]
- Šola, H.M.; Gajdoš Kljusurić, J.; Šestanović, A. Predicted visual attention and cognitive demand in luxury beauty retail: An exploratory AI-based neuromarketing study. Front. Commun. 2026, 11, 1933317. [Google Scholar] [CrossRef] [Scilit]
- Ni, J.; Shao, Y.; Guo, Y.; Gu, Y. Interpretable quantification of scene-induced driver visual load: Linking eye-tracking behavior to road scene features via SHAP analysis. J. Eye Mov. Res. 2025, 18, 40. [Google Scholar] [CrossRef] [Scilit]
- Selvaraju, R.R.; Cogswell, M.; Das, A.; Vedantam, R.; Parikh, D.; Batra, D. Grad-CAM: Visual explanations from deep networks via gradient-based localization. In Proceedings of the IEEE International Conference on Computer Vision (ICCV), Venice, Italy, 22–29 October 2017; pp. 618–626. [Google Scholar]
- Vinogradova, K.; Dibrov, A.; Myers, G. Towards interpretable semantic segmentation via gradient-weighted class activation mapping (student abstract). Proc. AAAI Conf. Artif. Intell. 2020, 34, 13943–13944. [Google Scholar] [CrossRef] [Scilit]
- Alhazmi, A. SleepStageNet: A lightweight and explainable deep learning architecture for multi-channel sleep staging. Brain Sci. 2026, 16, 860. [Google Scholar] [CrossRef] [Scilit]
- Hooker, S.; Erhan, D.; Kindermans, P.-J.; Kim, B. A benchmark for interpretability methods in deep neural networks. In Proceedings of the Advances in Neural Information Processing Systems 32, Vancouver, BC, Canada, 8–14 December 2019. [Google Scholar]
- Petsiuk, V.; Das, A.; Saenko, K. RISE: Randomized input sampling for explanation of black-box models. In Proceedings of the British Machine Vision Conference (BMVC), Newcastle upon Tyne, UK, 3–6 September 2018. [Google Scholar]
- Judd, T.; Ehinger, K.; Durand, F.; Torralba, A. Learning to predict where humans look. In Proceedings of the IEEE International Conference on Computer Vision (ICCV), Kyoto, Japan, 27 September–4 October 2009; pp. 2106–2113. [Google Scholar]
- Bylinskii, Z.; Judd, T.; Oliva, A.; Torralba, A.; Durand, F. What do different evaluation metrics tell us about saliency models? IEEE Trans. Pattern Anal. Mach. Intell. 2019, 41, 740–757. [Google Scholar] [CrossRef] [Scilit]
- Tatler, B.W. The central fixation bias in scene viewing: Selecting an optimal viewing position independently of motor biases and image feature distributions. J. Vis. 2007, 7, 4. [Google Scholar] [CrossRef] [Scilit]
- Ioannidou, F.; Hermens, F.; Hodgson, T.L. The central bias in day-to-day viewing. J. Eye Mov. Res. 2016, 9, 1–13. [Google Scholar] [CrossRef] [Scilit]
- Mairon, R.; Ben-Shahar, O. Stimulus center bias persists irrespective of its position on the display. J. Eye Mov. Res. 2025, 18, 77. [Google Scholar] [CrossRef] [Scilit]
- Le Meur, O.; Baccino, T. Methods for comparing scanpaths and saliency maps: Strengths and weaknesses. Behav. Res. Methods 2013, 45, 251–266. [Google Scholar] [CrossRef] [Scilit]
- Prosser, J.; Metzger, A.; Toscani, M. A data-driven approach for comparing gaze allocation across conditions. J. Eye Mov. Res. 2026, 19, 33. [Google Scholar] [CrossRef] [Scilit]
- Ronneberger, O.; Fischer, P.; Brox, T. U-Net: Convolutional networks for biomedical image segmentation. In MICCAI 2015; Springer: Cham, Switzerland, 2015; pp. 234–241. [Google Scholar]
- Chattopadhay, A.; Sarkar, A.; Howlader, P.; Balasubramanian, V.N. Grad-CAM++: Generalized gradient-based visual explanations for deep convolutional networks. In Proceedings of the IEEE Winter Conference on Applications of Computer Vision (WACV), Lake Tahoe, NV, USA, 12–15 March 2018; pp. 839–847. [Google Scholar]
- Simonyan, K.; Vedaldi, A.; Zisserman, A. Deep inside convolutional networks: Visualising image classification models and saliency maps. arXiv 2013, arXiv:1312.6034. [Google Scholar]
- Sundararajan, M.; Taly, A.; Yan, Q. Axiomatic attribution for deep networks. In Proceedings of the 34th International Conference on Machine Learning (ICML), Sydney, Australia, 6–11 August 2017; pp. 3319–3328. [Google Scholar]
- Lundberg, S.M.; Lee, S.-I. A unified approach to interpreting model predictions. In Proceedings of the Advances in Neural Information Processing Systems 30, Long Beach, CA, USA, 4–9 December 2017; pp. 4765–4774. [Google Scholar]
- Kokhlikyan, N.; Miglani, V.; Martin, M.; Wang, E.; Alsallakh, B.; Reynolds, J.; Melnikov, A.; Kliushkina, N.; Araya, C.; Yan, S.; et al. Captum: A unified and generic model interpretability library for PyTorch. arXiv 2020, arXiv:2009.07896. [Google Scholar]
- Zeiler, M.D.; Fergus, R. Visualizing and understanding convolutional networks. In Computer Vision—ECCV 2014; Springer: Cham, Switzerland, 2014; pp. 818–833. [Google Scholar]
- Holmqvist, K.; Nyström, M.; Andersson, R.; Dewhurst, R.; Jarodzka, H.; van de Weijer, J. Eye Tracking: A Comprehensive Guide to Methods and Measures; Oxford University Press: Oxford, UK, 2011. [Google Scholar]
- Kindermans, P.-J.; Hooker, S.; Adebayo, J.; Alber, M.; Schütt, K.T.; Dähne, S.; Erhan, D.; Kim, B. The (un)reliability of saliency methods. In Explainable AI: Interpreting, Explaining and Visualizing Deep Learning; Springer: Cham, Switzerland, 2019; pp. 267–280. [Google Scholar]
- Olivier, B.; Guérin-Dugué, A.; Durand, J.-B. Hidden semi-Markov models to segment reading phases from eye movements. J. Eye Mov. Res. 2022, 15, 1–19. [Google Scholar] [CrossRef] [Scilit]
- Alhazmi, A. Leakage-controlled classification of dataset-derived ordinal p53-signature size categories in fallopian-tube immunohistochemistry. Diagnostics 2026, 16, 2869. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.



