Skip to Content
SensorsSensors
  • Article
  • Open Access

27 November 2026

19 Pages

Chitosan-Derived Carbon Dots for Fluorescence Detection of Hg2+: Selectivity, Real-Water Assessment, and Computational Insights

,
,
and
1
Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
2
Department of Chemistry, Facultyof Science, University of Jeddah, Jeddah 21959, Saudi Arabia
*
Author to whom correspondence should be addressed.
This article belongs to the Section Chemical Sensors

Abstract

Carbon dots (CDs) were prepared from chitosan by a one-step hydrothermal route without dopants or post-synthetic modification and assessed as fluorescent probes for aqueous Hg2+. Characterization revealed mostly disordered carbonaceous nanodomains bearing nitrogen- and oxygen-containing surface groups, with an apparent BET surface area of 223.18 m2 g−1. The intrinsic fluorescence remained stable for 120 h and after six months at 4 °C; the storage stability of the Hg2+ response was not evaluated. Hg2+ caused the strongest quenching among the tested metals (65.22%). Coexisting Ni2+, Cu2+, and Pb2+ attenuated this quenching from 65.72% to 19.53–34.36%, whereas Fe3+ had little effect. The response was linear over 0.5–5 µM (quantification range 0.956–5 µM), and 0.1 µM Hg2+ was clearly detected. Hg2+-induced quenching was retained in well water, wastewater, and tap water, although its magnitude was matrix-dependent. Illustrative density functional theory calculations on neutral-atom carbon quantum dot (CQD) models showed weaker adsorption for Hg@CQD (−0.60 eV) than for Cr@CQD but the smallest HOMO–LUMO gap (0.211 eV); because these models do not represent aqueous Hg2+ and Cr(VI), they cannot establish the quenching mechanism or selectivity. Chitosan-derived CDs are a fast-responding fluorescent platform for Hg2+, although recovery studies and matrix-matched calibration are required for quantitative use.

1. Introduction

Mercury contamination is still a major environmental issue due to its toxicity, persistence, and tendency to build up within aquatic food webs [1]. Conventional analytical techniques that provide sensitive and precise trace mercury detection include atomic absorption spectroscopy, inductively coupled plasma mass spectrometry, and inductively coupled plasma optical emission spectrometry. However, these techniques require specialized equipment, trained personnel, and laboratory-based analysis [2]. Alternative approaches include electrochemical stripping methods and colorimetric assays based on metal nanoparticles [3,4], as well as fluorescent probes, which offer rapid, low-cost, and sensitive detection [5]. Molecular fluorescent probes for Hg2+ often rely on Hg2+-triggered reactions or coordination. For example, a fluorescein acetone hydrazone probe showed a turn-on response through spirolactam ring opening with an LOD of 7 nM [6], and a carbazole-based Schiff base probe showed a turn-off response with an LOD of 84 nM in DMSO/water (1:1, v/v) [7]. Such probes, however, often require organic synthesis and partially organic media, which motivates the use of water-dispersible nanomaterial probes. Carbon dots (CDs) are bright carbonaceous nanomaterials with strong water dispersibility, tunable photoluminescence, and surface chemistries that can interact with dissolved analytes [5,8]. Photoluminescence may involve contributions from surface states, conjugated carbon domains, and structural defects, whereas functional groups containing oxygen and nitrogen may provide interaction sites for metal species [8]. These characteristics have led to substantial research on CDs as fluorescent probes for heavy-metal ions, including Hg2+ [9,10]. Nevertheless, the fluorescence response of CD-based probes toward Hg2+ may be greatly influenced by precursor composition, surface chemistry, synthesis conditions, probe concentration, pH, and analyte–probe contact time [9,10]. Therefore, optimizing both CD preparation and sensing conditions is still necessary to achieve consistent analytical results.
During hydrothermal carbonization, chitosan, a renewable amino polysaccharide with a large number of amino and hydroxyl groups, can act as a precursor that contains both carbon and nitrogen [11]. A reasonably straightforward pathway to fluorescent nanomaterials with possible metal-binding sites is provided by the resultant chitosan-derived CDs, which may preserve heteroatom-containing surface functions without needing extra post-synthetic functionalization [11,12]. As a result, CDs generated from chitosan and other biomass have been investigated for Hg2+ sensing; systems have been reported to exhibit responses spanning micromolar concentration ranges and, in certain instances, sub-micromolar detection limits [12,13]. The promise of CD-based systems for mercury detection in increasingly complicated aqueous matrices has been further shown in more recent investigations [14,15]. However, due to variations in precursor chemistry, surface modification, calibration method, quenching analysis, and matrix validation, direct comparison amongst reported sensors is still challenging.
This work used a one-step hydrothermal method to create chitosan-derived CDs without the need for external dopants or post-synthetic surface modification. The resultant CDs were analyzed for their concentration-dependent quenching, response duration, and preferred fluorescence response toward Hg2+ after the impacts of hydrothermal conditions and fluorescence measurement settings were methodically assessed. The overall quenching behavior was initially evaluated using conventional Stern–Volmer analysis, and when departure from a single linear response was seen, the modified Stern–Volmer (Lehrer) model was then employed to better characterize heterogeneous fluorophore accessibility. Additionally, the fluorescence response caused by Hg2+ was assessed in various water matrices. In order to compare Hg–CQD and Cr–CQD interactions and investigate whether variations in electronic perturbation may be responsible for the empirically observed fluorescence behaviors, density functional theory simulations were utilized as a supplementary qualitative method. Rather than seeking improved sensitivity over earlier chitosan-derived probes [12], this work characterizes the practical response of unmodified chitosan-derived CDs, including the nonlinear concentration dependence, the effect of coexisting ions, optical interference from Cr(VI), and matrix-dependent quenching in real water samples.

2. Materials and Methods

2.1. Materials and Instrumentation

Chitosan (purity >95%, molecular weight 600–800 kDa, degree of deacetylation ≥90%, viscosity 50–200 mPa·s; Thermo Scientific, Acros Organics, Geel, Belgium, product 42885) was used as the carbon precursor, and glacial acetic acid (≥99.7%, Sigma-Aldrich, St. Louis, MO, USA) was used for its dissolution. HgCl2, Pb(NO3)2, Cu(NO3)2, Ni(NO3)2, Fe(NO3)3, and K2Cr2O7 were used to prepare the investigated metal solutions. HCl and NaOH (0.1 M) were used for pH adjustment. All reagents were of analytical grade and used without further purification.
UV–Vis spectra were recorded using a Lambda 35 spectrophotometer (PerkinElmer, Waltham, MA, USA), and fluorescence measurements were performed using a Cary Eclipse spectrofluorometer (Agilent Technologies, Santa Clara, CA, USA). Structural and morphological characterization was conducted by FTIR (Spectrum 100, PerkinElmer), SEM (JSM-6510LV, JEOL, Tokyo, Japan), TEM (Talos F200i, Thermo Fisher Scientific, Waltham, MA, USA), and XRD (D8 DISCOVER, Bruker, Karlsruhe, Germany). Nitrogen adsorption–desorption measurements were performed using a Nova Touch LX4 analyzer(Quantachrome Instruments, Boynton Beach, FL, USA), and the specific surface area and pore characteristics were evaluated using the BET and BJH methods, respectively. For N2 physisorption at 77.35 K, 10.1 mg of the freeze-dried sample was degassed under vacuum at 180 °C for 6 h; the BET surface area was obtained from seven points between P/P0 = 0.05 and 0.30. Thermogravimetric analysis (10.1 mg sample) was performed from 30 to 595 °C at 20 °C min−1 under nitrogen flow (Linseis, Selb, Germany).

2.2. Synthesis and Optimization of Chitosan-Derived CDs

Carbon dots were synthesized by a one-step hydrothermal method without external dopants or post-synthetic surface modification. Chitosan (1.0 g) was dissolved in 100 mL of 1% (v/v) acetic acid with overnight stirring. A 60 mL portion of the solution was transferred to a 100 mL Teflon-lined autoclave (60% filling) and heated under the optimized conditions (180 °C, 10 h). After cooling, the suspension was filtered through a 0.22 µm membrane and centrifuged at 4000 rpm for 60 min to remove insoluble residues and large aggregates. The concentration of the purified supernatant, determined gravimetrically by freeze-drying a known volume, was 0.5 mg mL−1; the 1:3 (v/v) dilution used for sensing corresponds to 0.125 mg mL−1. Because no dialysis or size-exclusion step was applied, soluble low-molecular-weight fluorescent by-products were not separated from the CDs, and the reported optical and sensing properties refer to the purified supernatant as a whole. The recovered supernatant was used for fluorescence studies, while a portion was freeze-dried for solid-state characterization (Figure 1). The effects of synthesis temperature and reaction time were evaluated at 180, 200, and 220 °C for 10 h and at 180 °C for 6, 8, 10, and 12 h, respectively. All samples were purified under identical conditions. The temperature series was measured after a 1:3 (v/v) dilution, whereas the reaction-time series was measured on the undiluted suspensions on a different day.
Figure 1. Schematic representation of the hydrothermal synthesis of chitosan-derived carbon dots (CDs) at 180 °C for 10 h, followed by purification and their application for fluorescence-based Hg2+ sensing.

2.3. Optical Properties and Optimization of Fluorescence Conditions

UV–Vis absorption spectra were recorded over the wavelength range of 200–800 nm. Excitation-dependent fluorescence was investigated at excitation wavelengths ranging from 300 to 400 nm in 10 nm increments. The effect of CD concentration on fluorescence intensity was evaluated using the undiluted CD suspension and CD-to-water volume ratios of 1:1, 1:3, 1:8, and 1:10 (v/v). The effect of pH was examined over the range of pH 1–12, with the pH adjusted using 0.1 M HCl or NaOH. Fluorescence stability was monitored for up to 120 h and after six months of storage at 4 °C in the dark, while thermal stability was evaluated following exposure to temperatures ranging from 15 to 100 °C.
The fluorescence quantum yield (QY) of the CDs was determined using the comparative method with fluorescein in 0.1 M NaOH as the reference standard (Φref = 0.925). A series of diluted fluorescein and CD solutions with low absorbance at the excitation wavelength (340 nm) were prepared. For each series, the integrated fluorescence intensity was plotted against the corresponding absorbance, and the slope of the resulting linear regression was obtained. The quantum yield of the CDs was calculated according to:
Φ CDs = Φ ref × mCDs m   ref × ( nCDs nref ) 2  
where ΦCDs and Φref are the fluorescence quantum yields of the CDs and reference standard, respectively; m_CDs and m_ref are the slopes obtained from the plots of integrated fluorescence intensity versus absorbance; and n_CDs and n_ref are the refractive indices of the respective solvents. Because both the CD and reference solutions were prepared in aqueous media with comparable refractive indices, the refractive-index correction term, (n_CDs/n_ref)2, was approximated as unity.

2.4. Fluorescence Sensing of Hg2+

The CD stock (0.5 mg mL−1) was diluted 1:3 (v/v) with deionized water. For each measurement, 1 mL of the diluted CDs was mixed with 1 mL of the analyte solution at pH 7.0 (final volume 2 mL; final CD concentration 0.0625 mg mL−1). Hg2+ was tested at 0, 0.1, 0.2, 0.5, 1, 2, 3, 4, 5, 7, and 10 µM. All Hg2+ and metal-ion concentrations in this work are expressed as concentrations in the analyte solution before 1:1 (v/v) mixing with the CD dispersion; the corresponding final concentrations in the cuvette are half of these values. After incubation for 2 min at room temperature, emission spectra were recorded with excitation at 340 nm, and the intensity at 436 nm was used for analysis (excitation and emission slits 5 and 10 nm; PMT voltage medium, 600 V; uncorrected spectra). The blank contained 1 mL of deionized water in place of the analyte. All measurements were performed in triplicate using independently prepared samples, and results are reported as mean ± standard deviation.
The preferential response was evaluated against Hg2+, Cr(VI), Cu2+, Ni2+, Pb2+, and Fe3+ (each at 100 µM) at pH 7.0 using an excitation wavelength of 340 nm. The same 1:1 (v/v) mixing procedure was used, but with a different CD dilution and sample volume from those of the calibration series (Section 3.7). The relative fluorescence response was calculated as
F − F 0 / F 0  
where F0 and F are the fluorescence intensities before and after the addition of the tested species, respectively. The response was multiplied by 100 and expressed as a percentage. Measurements were performed in triplicate. Competitive interference was evaluated by measuring the response to 100 µM Hg2+ in the presence of 1 mM Ni2+, Cu2+, Pb2+, or Fe3+ (10-fold excess) under the same conditions.
The time-dependent response to Hg2+ was monitored after the addition of 100 µM Hg2+ (single measurement series), with fluorescence measurements collected at predetermined intervals. Concentration-dependent quenching was evaluated over 0–10 µM Hg2+ using the fluorescence ratio F0/F. The overall response was first assessed using the Stern–Volmer relationship:
F 0 / F = 1 + K SV H g 2 +
Because the full concentration range deviated from a single linear relationship, the data were further analyzed using the modified Stern–Volmer (Lehrer) model:
F 0 F 0 − F = 1 f a + 1 f a K a H g 2 +
where fa is the fraction of fluorescence accessible to Hg2+ and Ka is the corresponding apparent quenching constant. The linear portion of the F0/F response was used for analytical calibration. The LOQ was calculated as 10σ/S, where σ is the residual standard deviation of the calibration regression and S is its slope.

2.5. Evaluation in Water Samples

The fluorescence response toward Hg2+ was examined in deionized, tap, well, and wastewater samples. Samples were filtered through a 0.22 µm membrane, adjusted to approximately pH 7 where required, and spiked with Hg2+ at 1, 3, and 5 µM. Quenching efficiency was calculated as
FQE % = F 0 − F F 0 × 100
and all measurements were performed in triplicate.

2.6. Computational Calculations

Density functional theory (DFT) calculations were performed using ORCA 6.1.0 with a C38H18N6O6 carbon quantum dot CQD model containing nitrogen sites and terminal –COOH and –NH2 groups [16]. Geometry optimizations were carried out using the r2SCAN-3c composite method, which incorporates the mTZVP basis set, D4 dispersion correction, and geometrical counterpoise (gCP) correction. To confirm that the obtained geometries represent stable minima, a vibrational frequency analysis was carried out at the same level for all optimized structures, demonstrating the absence of imaginary frequencies. Aqueous solvation was represented using the conductor-like polarizable continuum model (CPCM) [17,18,19]. Both metals were modeled as neutral atoms in the zero oxidation state, which do not represent the aqueous Hg2+ and Cr(VI) species. Hg(0) (5d106s2) is closed-shell, and Hg@CQD was treated in the singlet state. Neutral Cr(0) has a 7S (3d54s1) septet ground state with a low-lying quintet, so Cr@CQD was evaluated in both the quintet and septet states. Adsorption energies for both spin states were referenced to the septet ground-state Cr atom. Adsorption energies were calculated as:
E_ads = E(M@CQD) − E(CQD) − E(M)
where E(M@CQD) is the total energy of the metal–CQD complex, E(CQD) is the energy of the isolated CQD model, and E(M) is the energy of the isolated metal species. Frontier molecular orbital energies of the unbound CQD model and the optimized complexes were also analyzed. All systems were treated as neutral (total charge 0). The computational details, the Cartesian coordinates of all optimized structures, and the ORCA input files are provided in the Supplementary Information (Table S1 and Section S2).

3. Results and Discussion

3.1. Structural and Morphological Characterization

The XRD pattern exhibited a single broad diffraction feature centered at approximately 2θ = 23–24°, corresponding to a d-spacing of approximately 3.786 Å (Figure 2a). The broad profile is consistent with predominantly disordered carbonaceous domains with limited short-range graphitic ordering rather than well-stacked crystalline graphite [20,21,22]. The relatively large d-spacing may be associated with structural disorder and the presence of heteroatom-containing surface functionalities within the carbonaceous structure. For both the CDs and the fluorescein reference, the integrated fluorescence intensity increased linearly with absorbance at 340 nm (Figure S7), with slopes of 3.992 × 107 (R2 = 0.9983) and 4.458 × 108 (R2 = 0.9735), respectively. Using fluorescein in 0.1 M NaOH as the reference (Φref = 0.925), the fluorescence quantum yield of the CDs was 8.28%.
Figure 2. (a) CDs’ XRD pattern, which shows a wide diffraction feature centered around 23–24°, suggesting a mostly disordered carbonaceous structure and (b) FTIR spectra of pristine chitosan and the chitosan-derived carbon dots (CDs), displaying the distinctive absorption bands linked to their surface functional groups.
FTIR analysis indicated changes in the chemical structure of chitosan following hydrothermal treatment, as evidenced by differences in the characteristic absorption bands (Figure 2b). Pristine chitosan exhibited characteristic bands at 3312.92 cm−1, assigned to O–H/N–H stretching, 2868.33 cm−1 to C–H stretching, and 1659.60 and 1583.13 cm−1 to amide-related vibrations and N–H bending. Following hydrothermal treatment, a broad O–H/N–H band remained at 3315.68 cm−1, together with bands at 1644.09, 1225.50, and 1192.67 cm−1. In contrast, the characteristic polysaccharide bands near 1063 and 1026 cm−1 were markedly diminished. These spectral changes are consistent with disruption of the original chitosan structure during hydrothermal carbonization, while the remaining bands indicate the presence of nitrogen- and oxygen-containing surface functionalities in the resulting CDs [20,21].
SEM imaging showed irregular surface features with pronounced aggregation of the CDs (Figure 3a–d). TEM observations further revealed predominantly rounded to quasi-spherical nanoscale domains (Figure 3e–h), which were largely aggregated. Because the CDs were largely aggregated, only particles with clearly resolved boundaries at the aggregate edges could be measured (n = 19, from two non-overlapping images). Their diameters, determined by fitting a circle to each particle edge, ranged from 10.8 to 28.3 nm, with a mean of 20.4 ± 4.9 nm (Figure S6). Given the small number of particles and their selection from aggregate edges, these values are a limited estimate of the size of the resolvable particles rather than a representative size distribution of the CDs. These morphological observations confirm the nanoscale characteristics of the prepared CDs. In addition, the TEM findings, together with the broad XRD feature, support the formation of structurally disordered carbon domains.
Figure 3. SEM (a–d) and TEM (e–h) images of chitosan-derived carbon dots.
The N2 adsorption–desorption isotherm (Figure S8a) showed no distinct monolayer knee and resembled a type III isotherm, with a BET C constant of 2.2, indicating weak adsorbent–adsorbate interactions. The apparent BET surface area was 223.18 m2 g−1, which should be regarded as an approximate value for this isotherm type [23,24]. BJH analysis [25] of the adsorption branch gave a pore volume of 0.180 cm3 g−1 and a BJH surface area of 96.79 m2 g−1, with most of the pore volume in pores smaller than about 15 nm and the largest contribution at the smallest resolved diameter (≈3.85 nm) (Figure S8b). The average pore diameter, estimated as 4V/S from the total pore volume (0.206 cm3 g−1 at P/P0 = 0.997) and the BET surface area, was 3.69 nm, consistent with a mesoporous texture. A hysteresis loop extending to low relative pressures was observed (Figure S8a), which may reflect swelling or slow equilibration of the soft carbonaceous material rather than capillary condensation in rigid mesopores; the textural parameters are therefore treated as approximate.

3.2. Thermal Behavior

With almost 78% of the original mass preserved, the TGA profile (Figure S9) revealed an initial mass-loss region between roughly 30 and 130–150 °C. Desorption of moisture and weakly bound volatile species from the hydrophilic carbonaceous material is consistent with this initial loss [22]. About 74% of the starting mass remained at the conclusion of the experiment, showing very low thermal degradation of the remaining carbon framework under the applied conditions. Only a modest further mass loss was seen above about 150 °C.

3.3. Optical Properties

The UV–Vis spectrum showed a prominent absorption peak at approximately 220 nm and, for a diluted sample, a band with a maximum at approximately 305 nm and a shoulder near 330 nm (Figure 4). The wider feature at longer wavelengths is typically ascribed to n–π* transitions involving carbonyl-containing and related surface states, whereas the higher-energy band is typically linked to π–π* transitions inside conjugated carbon domains [8,26]. These characteristics are compatible with a carbonaceous structure that has both chemically functionalized surface sites and conjugated domains. Additionally, the CDs showed wide excitation-dependent photoluminescence. The CD dispersion appeared pale yellow under ambient light and showed blue-green fluorescence under a UV lamp (Figure S13). The emission maximum shifted gradually from approximately 428 nm to 472 nm as the excitation wavelength increased from 320 to 400 nm, and the strongest emission was obtained with excitation at 340 nm (maximum at 436 nm) (Figure S10). Many CDs exhibit excitation-dependent emission, which has been linked to heterogeneous emissive environments that include conjugated carbon domains, surface states, and structural flaws [8,26]. The structural disorder shown by XRD and the functionalities, including nitrogen and oxygen, found by FTIR in the current CDs are compatible with the existence of many emissive environments that might be responsible for the observed behavior. Because soluble molecular fluorophores were not removed during purification (Section 2.2), they may also contribute to the observed emission.
Figure 4. UV–Vis absorption and photoluminescence emission spectra of the chitosan-derived carbon dots (CDs), showing the characteristic absorption features in the UV region and a broad fluorescence emission band centered at approximately 430–440 nm.

3.4. Optimization of Hydrothermal Synthesis Conditions

The fluorescence properties of the chitosan-derived CDs were strongly affected by hydrothermal synthesis conditions. At a constant reaction time of 10 h, increasing the temperature from 180 to 200 and 220 °C decreased the fluorescence intensity from 683.62 to 297.11 and 144.82, corresponding to reductions of approximately 56.5% and 78.8%, respectively (Figure 5). Hydrothermal temperature influences precursor dehydration, carbonization, surface chemistry, and the formation of emissive states; excessive thermal treatment may promote further carbonization at the expense of fluorescence-active surface environments [22,27]. Accordingly, 180 °C was selected for subsequent experiments.
Figure 5. Effect of hydrothermal synthesis conditions on the fluorescence intensity of chitosan-derived carbon dots (CDs): (a) synthesis temperature (10 h; measured after 1:3 dilution) and (b) reaction time (180 °C; measured undiluted, on a different day). Absolute intensities are comparable only within each series.
At 180 °C, reaction time produced a non-monotonic fluorescence response, with intensities of 235.35, 80.77, 274.23, and 281.12 a.u. after 6, 8, 10, and 12 h, respectively (Figure 5b). A similar decrease followed by a recovery of fluorescence intensity with treatment time has been reported and attributed to the interplay of carbonization, structural reorganization, and particle dispersibility [28]. Comparable processes may account for the minimum at 8 h, although the present fluorescence data cannot identify its specific origin. Reaction time can alter the extent of precursor conversion, carbonization, and development of surface-related emissive states [21,22,27]. Although the highest intensity was obtained at 12 h, it exceeded that at 10 h by only approximately 2.5%. Therefore, 10 h was selected because it provided comparable fluorescence with a shorter processing time. The optimized synthesis conditions were thus established as 180 °C for 10 h. The temperature series was measured after 1:3 (v/v) dilution, whereas the reaction-time series was measured on undiluted suspensions on a different day; absolute intensities are therefore compared only within each series. Because the undiluted suspensions are subject to self-absorption and inner-filter effects (Section 3.5), the minimum at 8 h may partly reflect differences in sample absorbance and is interpreted with caution.

3.5. Fluorescence Stability and Measurement Optimization

The fluorescence of the CD suspension remained stable during storage. The intensity changed from 603.29 initially to 640.38 after 120 h (Figure 6a), corresponding to an increase of approximately 6.1%, with no measurable fluorescence loss. After six months of storage at 4 °C in the dark, an intensity of 638.63 was retained. Because temporal variations in the probe’s intrinsic emission may potentially lead to variability in analytical data, this stability is beneficial for fluorescence sensing [29]. These data describe the stability of the intrinsic CD fluorescence; the Hg2+ response of stored CDs was not evaluated and will be examined in future work.
Figure 6. Optimization of the fluorescence response of the CDs: (a) stability of the CD fluorescence during storage; (b) effect of CD dilution on the fluorescence intensity at various CD:H2O ratios; and (c) effect of pH (1–12) on the emission intensity. Error bars in (b,c) represent the standard deviation (n = 3).
The measured fluorescence intensity depended strongly on CD concentration. The undiluted suspension gave 208.90 ± 0.70 a.u., which increased to 405.28 ± 0.77, 728.30 ± 0.44, and 810.76 ± 0.64 a.u. at CD:H2O ratios of 1:1, 1:3, and 1:8, respectively, before decreasing to 648.59 ± 0.70 a.u. at 1:10 (n = 3). Aggregation, self-absorption, and inner-filter effects are examples of concentration-dependent processes that might be responsible for the decreased emission at higher CD concentrations [30,31]. The 1:3 ratio was used for subsequent sensing because it retained about 89.8% of the maximum signal while keeping a higher CD concentration (Figure 6b).
After being exposed to temperatures between 15 and 100 °C, the CDs continued to exhibit detectable fluorescence. The fluorescence intensity was 339.11 at 100 °C, or around 79% of the starting value. Changes in surface-associated emissive states and thermally triggered non-radiative relaxation pathways can cause temperature-dependent variations in CD emission [22,32]. Nevertheless, no particular thermal-quenching process was established by the current observations.

3.6. Effect of pH

The fluorescence intensity showed a strong pH dependence over pH 1–12, with a maximum of 816.56 ± 1.51 a.u. at pH 7 (Figure 6c). Increasing the pH from 7 to 12 decreased the intensity to 393.72 ± 0.58 a.u., a reduction of approximately 51.8%. Protonation and deprotonation of surface groups containing nitrogen and oxygen can alter the electrical environment of emissive surface states, which is consistent with this behavior [33,34,35]. pH 7 was chosen for further Hg2+ sensing studies because it produced the greatest fluorescence intensity. However, the precise chemical source of the pH response cannot be determined by the fluorescence data alone.

3.7. Preferential Response, Interference, and Response Time Toward Hg2+

The CDs’ fluorescence response differed significantly among the metal species under investigation. Hg2+ produced the greatest quenching, reducing the fluorescence intensity by 65.22 ± 0.30% (from 341.83 ± 0.75 to 118.90 ± 1.01 a.u.). This quenching was visible to the naked eye under a UV lamp (Figure S12). By contrast, Cr(VI) and Fe3+ decreased the fluorescence intensity by only 18.61 ± 0.16% and 2.05 ± 0.14%, respectively, whereas Cu2+, Ni2+, and Pb2+ increased it by 4.22 ± 0.19%, 10.82 ± 0.23%, and 16.48 ± 0.25%, respectively (Figure S3; each ion at 100 µM, n = 3). Because this series was prepared with a different CD dilution and sample volume from the calibration series (blank intensity 341.83 vs. 601.81 a.u.), the quenching percentages are not directly comparable with those in Section 3.8. Cr(VI) absorbs strongly near the 340 nm excitation wavelength (absorbance ≈ 0.29 at 100 µM; Figure S5). The estimated inner-filter attenuation in the cuvette (≈17%) is close to the observed decrease (18.61%), indicating that the apparent quenching by Cr(VI) arises largely from an inner-filter effect. In line with other studies of Hg2+-responsive carbon-dot systems [10,14,36,37,38,39,40,41], the results therefore show preferential sensitivity toward Hg2+ among the investigated species. The strong Hg2+ response might be caused by interactions with the FTIR-identified surface functionalities that comprise nitrogen and oxygen. These surface interactions have the potential to disrupt the CDs’ emissive states and aid in the quenching of fluorescence [38,39,40,41]. Nevertheless, a particular quenching process cannot be established by the fluorescence and FTIR data alone; consequently, this interpretation is taken into account in conjunction with the computational results given below. Additionally, the response to Hg2+ (100 µM) was rapid. In a single measurement series (n = 1; Figure S14), the fluorescence intensity at 436 nm decreased from 579.17 to 330.02 a.u. within two minutes (43.02% quenching) and varied only between 344.00 and 349.69 a.u. from 10 to 120 min. Similar reports of quick Hg2+ responses in a few minutes have been made for various CD-based probes [42,43,44]. Because this experiment was not replicated, the 2 min incubation time was adopted as an operational condition for subsequent measurements.
To examine the interaction between Hg2+ and the CDs, FTIR and UV–Vis spectra were recorded before and after Hg2+ exposure. In the FTIR spectra, the broad O–H/N–H stretching band shifted from 3315.68 to 3346.70 cm−1, and the band at 1644.09 cm−1 shifted to 1634.84 cm−1 (Figure S1). In the UV–Vis spectrum, the band near 330 nm, associated with n–π* transitions of surface states, became less pronounced after Hg2+ addition (Figure S2). These changes indicate that Hg2+ perturbs the local environment of the nitrogen- and oxygen-containing surface groups. They support an interaction between Hg2+ and the CD surface, although the specific fluorescence-quenching pathway remains a proposed interpretation.
The effect of coexisting ions was examined by measuring the response to 100 µM Hg2+ in the presence of 1 mM Ni2+, Cu2+, Pb2+, or Fe3+. In this independent series, Hg2+ alone produced 65.72 ± 0.53% quenching. Ni2+, Cu2+, and Pb2+, which enhanced the CD fluorescence when tested alone, reduced the quenching to 34.36 ± 0.18%, 19.53 ± 0.41%, and 21.25 ± 0.21%, respectively, whereas Fe3+ had little effect (64.77 ± 0.23%) (Figure S4). Hg2+-induced quenching therefore persisted in all binary mixtures, but its magnitude was substantially attenuated by the fluorescence-enhancing ions. Cr(VI) was excluded because it absorbs strongly near the 340 nm excitation wavelength (Figure S5), which would introduce an inner filter effect and prevent the decrease in emission from being attributed to Hg2+. The preferential response observed in single-ion tests should therefore be distinguished from interference tolerance, and quantitative determination of Hg2+ in samples containing Ni2+, Cu2+, or Pb2+ would require matrix-matched calibration or a masking strategy.

3.8. Concentration-Dependent Hg2+ Quenching and Analytical Performance

As the Hg2+ concentration increased from 0 to 10 µM, the fluorescence intensity progressively decreased (Figure S11), while the F0/F ratio increased from 1.00 to 7.41. Similar concentration-dependent fluorescence quenching has been reported for other CD-based Hg2+ sensors [13,14,37,38,39,40,41,45,46]. A single linear Stern–Volmer relationship did not adequately describe the entire concentration range. However, a linear relationship was obtained over 0.5–5 µM using the means of triplicate measurements (Equation (7)):
F0/F = 0.6438[Hg2+] + 4.0027
with R2 = 0.9976. All calibration samples, including the blank, were prepared with identical final CD concentration, total volume, and pH, and the measured F0/F at zero Hg2+ was 1.00. The intercept therefore does not reflect quenching before Hg2+ addition. It arises from extrapolating the approximately linear 0.5–5 µM segment to zero concentration, below which the response rises steeply (Figure 7a). Accordingly, the slope of 0.6438 µM−1 was treated as an empirical calibration sensitivity rather than a conventional Stern–Volmer constant (KSV). Above 5 µM, the response approached a plateau, indicating that a single linear quenching model did not adequately describe the full concentration range. Such nonlinear Stern–Volmer behavior may be associated with heterogeneous emissive environments or differences in quencher accessibility [10]. The modified Stern–Volmer (Lehrer) model was therefore applied to further evaluate the nonlinear response (Equation (8); Figure 7b). Linear regression of F0/(F0 − F) versus 1/[Hg2+] gave:
F0/(F0 − F) = 0.04701(1/[Hg2+]) + 1.17990
with R2 = 0.9688. Under the assumptions of the Lehrer model, the accessible fraction was fa = 0.8475, corresponding to approximately 84.8% of the fluorescence being accessible to Hg2+. The associated apparent quenching constant was Ka = 2.51 × 107M−1. These parameters provide a quantitative description of heterogeneous fluorophore accessibility but do not, by themselves, establish a specific molecular quenching mechanism [10].
Figure 7. (a) F0/F of the CDs as a function of Hg2+ concentration (0–10 µM; mean ± SD, n = 3), with the linear 0.5–5 µM region and Equation (7) shown in the inset; (b) modified Stern–Volmer (Lehrer) plot of F0/(F0 − F) versus 1/[Hg2+], used to estimate the accessible fluorophore fraction and apparent quenching constant.
σ was taken as the residual standard deviation of the linear regression over 0.5–5 µM (σ = 0.0616). With the calibration slope of 0.6438 µM−1, the LOQ (10σ/S) was 0.956 µM (Table S2), which lies within the fitted range; the response is therefore linear over 0.5–5 µM, and quantitative determination is valid over 0.956–5 µM. A detection limit was not derived from this regression because 3.3σ/S falls below the lower end of the linear range, where the response is nonlinear, and the two concentrations tested below 0.5 µM are insufficient to define a separate low-concentration calibration. Detection was instead verified experimentally: at 0.1 µM, the lowest concentration tested, the emission intensity decreased from approximately 601 to 236 a.u. (F0/F ≈ 2.5; Table S2), a response clearly distinguishable from the blank. The detection capability is therefore reported as ≤0.1 µM, based on the lowest tested concentration, rather than as a statistically derived LOD; a dedicated calibration below 0.1 µM with replicate blank measurements is required to determine a formal LOD. This value lies within the range of LODs reported for CD-based Hg2+ probes (approximately 0.001–2.5 µM; Table 1). The present CDs require no dopants or post-synthetic modification, and their value lies in the characterization of the nonlinear, interference-sensitive, and matrix-dependent response rather than in superior sensitivity. However, direct comparison should consider differences in precursor composition, surface chemistry, calibration procedures, and sensing conditions.

3.9. Hg2+ Response in Water Samples

The applicability of the CDs in more complex matrices was examined using DI water, well water, wastewater, and tap water spiked with 1, 3, and 5 µM Hg2+. At 1 µM, the fluorescence quenching efficiency was 85.30% in DI water compared with 71.43%, 74.32%, and 75.51% in well water, wastewater, and tap water, respectively, demonstrating a clear matrix-dependent response. At 5 µM Hg2+, quenching efficiencies were approximately 90% in DI water and 81.55%, 75.04%, and 78.21% in well water, wastewater, and tap water, respectively (Table 2). The retained Hg2+ response in all matrices indicates that the fluorescence response persisted under more complex aqueous conditions, although its magnitude depended on the water matrix. Similar matrix effects have been observed in CD-based Hg2+ sensing studies using environmental or spiked water samples [47,48,49]. Importantly, these experiments demonstrate retention of the fluorescence response in real-water matrices rather than quantitative analytical recovery. To determine quantitative accuracy in environmental samples, further recovery tests, matrix-matched calibration, and interference investigations would be necessary.
The well water had a pH of 6.0 and an electrical conductivity of 1.14 mS/cm, indicating a substantial dissolved-salt content. The lower response in this matrix may arise from dissolved cations competing with Hg2+ for surface binding sites, from anions such as chloride complexing Hg2+, or from the higher ionic strength altering the CD surface environment. Because hardness, TOC, and alkalinity were not determined, the observed differences are attributed to matrix effects, in general, rather than to a specific constituent.
The FQE values in deionized water were obtained in a separate series that included filtration and pH adjustment and are therefore not directly comparable with the calibration in Equation (7) (e.g., 85.30% vs. 78.58% at 1 µM). Because recovery experiments were not performed, these results demonstrate retention of the Hg2+ response in real water matrices rather than quantitative determination.
Table 1. Comparison of LODs of carbon-dot fluorescent probes for Hg2+.
Table 2. CDs’ fluorescence quenching efficiency (FQE) against mercury in various water matrices. Values are mean ± SD (n = 3); FQE was calculated relative to the CDs in the same water matrix.

3.10. Hg– and Cr–CQD Interactions: Computational Interpretation

The interactions of Hg and Cr with a representative carbon quantum dot (CQD) model were compared using DFT calculations to examine whether differences in adsorption and electronic structure could be related to the different fluorescence responses observed experimentally. Cr was selected for comparison because Cr(VI) produced the second-largest decrease in fluorescence (18.61%) after Hg2+ (65.22%), whereas Cu2+, Ni2+, and Pb2+ enhanced the fluorescence and Fe3+ had a negligible effect. The calculations therefore contrast the two species that decreased the fluorescence (the decrease caused by Cr(VI) arising largely from an inner filter effect; Section 3.7) and do not address the responses to the other metals.
The calculations were interpreted qualitatively since simplified neutral Hg and Cr atoms were used instead of the actual Hg2+ and Cr(VI) species. The r2SCAN-3c approach was used with CPCM water solvation, as described in Section 2.6 [16,17,18,19].
Different metal–CQD interactions were obtained by geometry optimization. The Hg@CQD model had interaction lengths of around 3.47–3.56 Å and an adsorption energy of −0.60 eV, whereas the Cr@CQD models produced adsorption values of −2.23 eV for the quintet state and −0.91 eV for the septet state (Figure 8). Therefore, in the simpler models, Cr adsorption was more favorable energetically than Hg adsorption. Similar computational methods have been used to study metal-carbon-dot interactions and the role of surface chemistry in metal-ion sensing [52,53,54]. Importantly, this adsorption-energy pattern did not match the actual fluorescence response: Hg2+ caused far more quenching than Cr(VI). Within these simplified models, the calculated adsorption strength therefore does not follow the experimental quenching trend.
Figure 8. Optimized adsorption configurations and calculated adsorption energies of Hg@CQD, Cr@CQD (M = 5), and Cr@CQD (M = 7) at the r2SCAN-3c/CPCM(water) level.
Frontier molecular orbital analysis revealed a further difference between the models. Relative to the unbound CQD model (HOMO–LUMO gap 1.517 eV; Table S3), the Hg@CQD model showed the smallest gap (0.211 eV), compared with global spin-polarized gaps of 0.384 eV (M = 5) and 0.402 eV (M = 7) for the Cr@CQD models, whose individual spin-channel gaps ranged from 0.402 to 0.824 eV (Table S3). In Hg@CQD, the HOMO was mostly distributed across the π-conjugated CQD framework, whereas the LUMO showed increased density around the Hg contact point (Figure 9). Such redistribution is congruent with electrical interaction between Hg and the CQD framework and may allow changes in charge distribution relevant to fluorescence quenching [55,56,57]. Similarly, computational studies of Hg-responsive carbon-dot systems have used orbital redistribution and changes in frontier electronic structure to evaluate fluorescence responses seen in experiments [52,54,55,56,57].
Figure 9. Frontier molecular orbital distributions of the optimized Hg@CQD and Cr@CQD systems calculated at the r2SCAN-3c/CPCM(water) level. Note: The orange and green isosurfaces represent the positive and negative phases of the molecular orbital wavefunctions.
Within these simplified neutral-atom models, Hg@CQD combined weaker adsorption with the smallest frontier-orbital gap and a redistribution of orbital density, which may tentatively indicate electronic perturbation of the CQD framework. However, ground-state orbital analysis cannot establish a quenching pathway, and the models do not represent the aqueous Hg2+ and Cr(VI) species; confirmation would require ionic models with explicit solvation, excited-state calculations, and time-resolved spectroscopy [10,54,57].

4. Conclusions

Chitosan-derived CDs were prepared by a one-step hydrothermal route without external dopants or post-synthetic surface modification. The optimized synthesis conditions of 180 °C for 10 h produced fluorescent, predominantly disordered carbonaceous nanostructures bearing oxygen- and nitrogen-containing surface functionalities. The CDs exhibited excitation-dependent emission and maintained their fluorescence during storage and under the investigated thermal conditions. Under the selected sensing conditions, Hg2+ generated the highest fluorescence quenching among the examined species, with a 65.22% decrease in fluorescence intensity and a response within two minutes. The analytical response was linear over 0.5–5 µM (R2 = 0.9976), with an LOQ of 0.956 µM, so quantitative determination is valid over 0.956–5 µM; Hg2+ at 0.1 µM, the lowest concentration tested, was clearly detected, but a formal LOD requires a dedicated low-concentration calibration. Modified Stern–Volmer analysis using the Lehrer model indicated an accessible fluorescence fraction of approximately 84.8%. Hg2+-induced fluorescence quenching was also maintained in tap, well, and wastewater samples, although the magnitude of the response varied depending on the water matrix. Coexisting Ni2+, Cu2+, and Pb2+ attenuated the Hg2+-induced quenching, so the preferential response observed in single-ion tests does not establish interference-free determination of Hg2+ in complex samples. DFT calculations on neutral-atom models revealed distinct electronic responses of the CQD model toward Hg and Cr. Because these models do not represent the aqueous Hg2+ and Cr(VI) species, the calculations are illustrative only and do not explain the experimentally observed selectivity; ionic models with explicit solvation will be required for that purpose. Overall, the results demonstrate the potential of unmodified chitosan-derived CDs as a fluorescent platform for rapid Hg2+ detection, although quantitative application in real water requires recovery experiments and matrix-matched calibration. Future studies should focus on quantitative recovery experiments, masking strategies for interfering ions, matrix-matched calibration, and excited-state or time-resolved investigations to further evaluate analytical performance and clarify the quenching mechanism in real-water systems.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/s26237505/s1, Figure S1: FTIR spectra of chitosan, CDs, and CDs after Hg2+ exposure; Figure S2: UV–Vis spectra of the CDs before and after Hg2+ addition; Figure S3: Single-ion selectivity of the CDs; Figure S4: Competitive interference experiments; Figure S5: UV–Vis spectrum of Cr(VI) (K2Cr2O7); Figure S6: TEM size histogram of CD particles with resolved boundaries; Figure S7: Quantum-yield plots; Figure S8: N2 adsorption–desorption isotherm and BJH pore-size distribution; Figure S9: Thermogravimetric analysis; Figure S10: Excitation-dependent emission spectra; Figure S11: Emission spectra of the CDs with increasing Hg2+ concentration; Figure S12: Photograph of the CD dispersion without and with Hg2+ under a UV lamp; Figure S13: Photographs of the CD dispersion under UV and ambient light; Figure S14: Time dependence of the fluorescence response to Hg2+; Table S1: Computational details of the optimized structures; Table S2: Calibration data and LOQ calculation; Table S3: Frontier molecular orbital energies; Section S2: Cartesian coordinates and ORCA input files of the optimized structures.

Author Contributions

M.G.A.: Data curation, Investigation, Methodology, Conceptualization, Writing—original draft, Writing—review & editing. O.S.A.-Q.: Data curation, Methodology, Conceptualization, Writing—review & editing. B.G.A.: Data curation, Investigation, Supervision, Resources, Conceptualization. Writing—original draft, Writing—review & editing. Z.Z.: Data curation, Investigation, Supervision, Resources, Conceptualization. Writing—original draft, Writing—review & editing. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. World Health Organization. Health and Mercury; WHO: Geneva, Switzerland, 2024. [Google Scholar]
  2. Baek, S.-O.; Suvarapu, L.N. Recent Studies on the Speciation and Determination of Mercury in Different Environmental Matrices Using Various Analytical Techniques. Int. J. Anal. Chem. 2017, 2017, 3624015. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Suherman, A.L.; Tanner, E.E.L.; Compton, R.G. Recent developments in inorganic Hg2+ detection by voltammetry. TrAC Trends Anal. Chem. 2017, 94, 161–172. [Google Scholar] [CrossRef] [Scilit]
  4. Poornima, V.; Alexandar, V.; Iswariya, S.; Perumal, P.T.; Uma, T.S. Gold nanoparticle-based nanosystems for the colorimetric detection of Hg2+ ion contamination in the environment. RSC Adv. 2016, 6, 46711–46722. [Google Scholar] [CrossRef] [Scilit]
  5. Lim, S.Y.; Shen, W.; Gao, Z. Carbon quantum dots and their applications. Chem. Soc. Rev. 2015, 44, 362–381. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Zavalishin, M.N.; Gamov, G.A. Fluorescein acetone hydrazone: A highly sensitive probe for Hg2+ ion detection and computational insights. J. Mol. Struct. 2025, 1348, 143405. [Google Scholar] [CrossRef] [Scilit]
  7. Bhanja, A.; Pandey, P.; Murugavel, R. Carbazole based Schiff base ligand: An efficient “Turn-on/off” sensor for the detection of Al3+ and F− ions and “Turn-off” sensor for Hg2+ ion. J. Photochem. Photobiol. A Chem. 2024, 447, 115269. [Google Scholar] [CrossRef] [Scilit]
  8. Yan, F.; Sun, Z.; Zhang, H.; Sun, X.; Jiang, Y.; Bai, Z. The fluorescence mechanism of carbon dots, and methods for tuning their emission color: A review. Microchim. Acta 2019, 186, 583. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Sekar, A.; Yadav, R.; Basavaraj, N. Fluorescence quenching mechanism and application of green carbon nanodots in detection of heavy metal ions: A review. New J. Chem. 2021, 45, 2326–2360. [Google Scholar] [CrossRef] [Scilit]
  10. Noun, F.; Jury, E.A.; Naccache, R. Elucidating the Quenching Mechanism in Carbon Dot–Metal Interactions—Designing Sensitive and Selective Optical Probes. Sensors 2021, 21, 1391. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Liu, X.; Pang, J.; Xu, F.; Zhang, X. Simple Approach to Synthesize Amino-Functionalized Carbon Dots by Carbonization of Chitosan. Sci. Rep. 2016, 6, 31100. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Wang, L.; Li, B.; Xu, F.; Shi, X.; Feng, D.; Wei, D.; Li, Y.; Feng, Y.; Wang, Y.; Jia, D.; et al. High-yield synthesis of strong photoluminescent N-doped carbon nanodots derived from hydrosoluble chitosan for mercury ion sensing via smartphone APP. Biosens. Bioelectron. 2016, 79, 1–8. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Xie, Y.; Cheng, D.; Liu, X.; Han, A. Green hydrothermal synthesis of N-doped carbon dots from biomass highland barley for detection Hg2+. Sensors 2019, 19, 3169. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Hou, J.; Chen, Q.; Meng, X.; Liu, H.; Feng, W. Synthesis of green fluorescent carbon dots and their application in mercury ion detection. RSC Adv. 2024, 14, 36273–36280. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Zhu, P.; Hou, S.-L.; Liu, Z.; Zhou, Y.; Alvarez, P.J.J.; Chen, W.; Zhang, T. Multi-Emission Carbon Dots Combining Turn-On Sensing and Fluorescence Quenching Exhibit Ultrahigh Selectivity for Mercury in Real Water Samples. Environ. Sci. Technol. 2024, 58, 9887–9895. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Neese, F. Software Update: The ORCA Program System—Version 6.0. WIREs Comput. Mol. Sci. 2025, 15, e70019. [Google Scholar] [CrossRef] [Scilit]
  17. Grimme, S.; Hansen, A.; Ehlert, S.; Mewes, J.-M. r2SCAN-3c: A “Swiss army knife” composite electronic-structure method. J. Chem. Phys. 2021, 154, 064103. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Kruse, H.; Grimme, S. A geometrical correction for the inter- and intramolecular basis set superposition error in Hartree–Fock and density functional theory calculations for large systems. J. Chem. Phys. 2012, 136, 154101. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Cossi, M.; Barone, V.; Mennucci, B.; Tomasi, J. Ab initio study of ionic solutions by a polarizable continuum dielectric model. Chem. Phys. Lett. 1998, 286, 253–260. [Google Scholar] [CrossRef] [Scilit]
  20. Villalba-Rodríguez, A.M.; González-González, R.B.; Martínez-Ruiz, M.; Flores-Contreras, E.A.; Cárdenas-Alcaide, M.F.; Iqbal, H.M.N.; Parra-Saldívar, R. Chitosan-Based Carbon Dots with Applied Aspects: New Frontiers of International Interest in a Material of Marine Origin. Mar. Drugs 2022, 20, 782. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Song, J.; Zhao, L.; Wang, Y.; Xue, Y.; Deng, Y.; Zhao, X.; Li, Q. Carbon Quantum Dots Prepared with Chitosan for Synthesis of CQDs/AuNPs for Iodine Ions Detection. Nanomaterials 2018, 8, 1043. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Sonsin, A.F.; Nascimento, S.M.S.; Albuquerque, I.M.B.; Silva, E.C.O.; Rocha, J.C.A.; Oliveira, R.S.; Barbosa, C.D.A.E.S.; Souza, S.T.; Fonseca, E.J.S. Temperature-dependence of the optical properties of carbon dots. RSC Adv. 2021, 11, 2767–2773. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Brunauer, S.; Emmett, P.H.; Teller, E. Adsorption of gases in multimolecular layers. J. Am. Chem. Soc. 1938, 60, 309–319. [Google Scholar] [CrossRef] [Scilit]
  24. Thommes, M.; Kaneko, K.; Neimark, A.V.; Olivier, J.P.; Rodriguez-Reinoso, F.; Rouquerol, J.; Sing, K.S.W. Physisorption of gases, with special reference to the evaluation of surface area and pore size distribution. Pure Appl. Chem. 2015, 87, 1051–1069. [Google Scholar] [CrossRef] [Scilit]
  25. Barrett, E.P.; Joyner, L.G.; Halenda, P.P. The determination of pore volume and area distributions in porous substances. I. Computations from nitrogen isotherms. J. Am. Chem. Soc. 1951, 73, 373–380. [Google Scholar] [CrossRef] [Scilit]
  26. Barman, M.K.; Patra, A. Current status and prospects on chemical structure driven photoluminescence behaviour of carbon dots. J. Photochem. Photobiol. C 2018, 37, 1–22. [Google Scholar] [CrossRef] [Scilit]
  27. Wang, X.; Hong, B.; Yang, X.; Liang, Q.; Huang, B.; Tang, L. Hydrothermal Preparation of Chitosan Carbon Dots and Their Selectivity to Metal Ions. Chin. J. Lumin. 2019, 40, 289–297. [Google Scholar] [CrossRef] [Scilit]
  28. Peng, Y.; Zhou, X.; Zheng, N.; Wang, L.; Zhou, X. Strongly tricolor-emitting carbon dots synthesized by the combined aging-annealing route and their bio-application. RSC Adv. 2017, 7, 50802–50811. [Google Scholar] [CrossRef] [Scilit]
  29. Tian, J.; An, M.; Zhao, X.; Wang, Y.; Hasan, M. Advances in Fluorescent Sensing Carbon Dots: An Account of Food Analysis. ACS Omega 2023, 8, 9031–9039. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Kompany-Zareh, M.; Bagheri, S. Perception on aggregation induced multicolor emission and emission centers in carbon nanodots using successive dilution, anion exchange chromatography, and multi-way statistics. Sci. Rep. 2021, 11, 13996. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  31. Abdelaal, S.H.; El-Kosasy, A.M.; Abdelrahman, M.H. One-pot synthesis of N-doped carbon dots from microwave irradiated egg white: Application to raspberry ketone assay by photo-induced charge transfer fluorescence sensing. Chem. Pap. 2023, 77, 3867–3879. [Google Scholar] [CrossRef] [Scilit]
  32. Mohammed, L.J.; Omer, K.M. Carbon Dots as New Generation Materials for Nanothermometer: Review. Nanoscale Res. Lett. 2020, 15, 182. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Hu, X.; Zhang, Y.; Li, H.; Cao, J.; Pan, J.; Li, C.; Zheng, Y. pH response mechanism of bifunctional fluorescent carbon quantum dots and application in cancer detection and bioself-targeting imaging. J. Mol. Struct. 2024, 1308, 137939. [Google Scholar] [CrossRef] [Scilit]
  34. Guo, H.; Lesani, P.; Zreiqat, H.; New, E.J. Fluorescent sensor array based on carbon dots for pH sensing. Sens. Diagn. 2024, 3, 1923–1934. [Google Scholar] [CrossRef] [Scilit]
  35. Minervini, G.; Panniello, A.; Quesada-González, D.; Maroli, G.; Fanizza, E.; Striccoli, M.; Álvarez-Diduk, R.; Curri, M.L.; Merkoçi, A. High-resolution portable platform for pH sensing via colorimetric fluorescence of carbon dots. Chem. Eng. J. 2025, 505, 159664. [Google Scholar] [CrossRef] [Scilit]
  36. Singaravelu, C.M.; Deschanels, X.; Rey, C.; Causse, J. Solid-State Fluorescent Carbon Dots for Fluorimetric Sensing of Hg2+. ACS Appl. Nano Mater. 2021, 4, 6386–6397. [Google Scholar] [CrossRef] [Scilit]
  37. Tan, Q.; Li, X.; Wang, L.; Zhao, J.; Yang, Q.; Sun, P.; Deng, Y.; Shen, G. One-step synthesis of highly fluorescent carbon dots as fluorescence sensors for the parallel detection of cadmium and mercury ions. Front. Chem. 2022, 10, 1005231. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Mohandoss, S.; Ahmad, N.; Khan, M.R.; Velu, K.S.; Palanisamy, S.; You, S.; Kumar, A.J.; Lee, Y.R. Nitrogen and sulfur co-doped photoluminescent carbon dots for highly selective and sensitive detection of Ag+2 and Hg+2 ions in aqueous media: Applications in bioimaging and real sample analysis. Environ. Res. 2023, 228, 115898. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Liu, H.; Xu, H.; Li, H. Detection of Fe+3 and Hg+2 Ions by Using High Fluorescent Carbon Dots Doped With S And N as Fluorescence Probes. J. Fluoresc. 2022, 32, 1089–1098. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  40. Kaur, H.; Kaur, N.; Singh, N. N/S co-doped fluorescent carbon dots for trapping Hg(II) from water. Mater. Adv. 2020, 1, 3009–3021. [Google Scholar] [CrossRef] [Scilit]
  41. Gao, Z.-H.; Lin, Z.-Z.; Chen, X.-M.; Zhong, H.-P.; Huang, Z.-Y. A fluorescent probe based on N-doped carbon dots for highly sensitive detection of Hg+2 in aqueous solutions. Anal. Methods 2016, 8, 2297–2304. [Google Scholar] [CrossRef] [Scilit]
  42. Guo, Y.; Zhang, L.; Cao, F.; Leng, Y. Thermal treatment of hair for the synthesis of sustainable carbon quantum dots and the applications for sensing Hg2+. Sci. Rep. 2016, 6, 35795. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  43. Long, X.; Hu, J.; Liu, H.; Wu, S. Ultraviolet Fluorescent Carbon Nanodots as Sensors for Hg2+ and Temperature. ACS Appl. Nano Mater. 2024, 7, 23434–23442. [Google Scholar] [CrossRef] [Scilit]
  44. Tanwar, L.K.S.; Sharma, S.; Ghosh, K.K. Spectroscopic detection of Hg2+ in water samples using fluorescent carbon quantum dots as sensing probe. Main. Group Chem. 2021, 20, 1–18. [Google Scholar] [CrossRef] [Scilit]
  45. Tang, M.; Ren, G.; Zhu, B.; Yu, L.; Liu, X.; Chai, F.; Wu, H.; Wang, C. Facile synthesis of orange emissive carbon dots and their application for mercury ion detection and fast fingerprint development. Anal. Methods 2019, 11, 2072–2081. [Google Scholar] [CrossRef] [Scilit]
  46. Ding, C.; Xing, H.; Guo, X.; Yuan, H.; Li, C.; Zhang, X.; Jia, X. Tea-derived carbon dots with two ratiometric fluorescence channels for Hg2+ and H2O sensing. Anal. Methods 2023, 15, 1998–2005. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  47. Ahmed, F.; Iqbal, S.; Zhao, L.; Xiong, H. "ON-OFF-ON" fluorescence switches based on N,S-doped carbon dots: Facile hydrothermal growth, selective detection of Hg2+, and as a reversive probe for guanine. Anal. Chim. Acta 2021, 1183, 338977. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  48. Xie, R.; Qu, Y.; Tang, M.; Zhao, J.; Chua, S.; Li, T.; Zhang, F.; Wheatley, A.E.H.; Chai, F. Carbon dot–magnetic nanocomposites for detection and removal of Hg2+. Food Chem. 2021, 364, 130366. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  49. Wang, M.; Huang, H.; Wang, L.; Sun, M.; Hou, H.; Yang, X. Carbon dots-based dual-emission proportional fluorescence sensor for ultra-sensitive visual detection of mercury ions in natural water. Colloids Surf. A 2023, 675, 132080. [Google Scholar] [CrossRef] [Scilit]
  50. Wang, Y.; Xu, G.; Zhang, X.; Yang, X.; Hou, H.; Ai, W.; Zhao, L. N- and S-codoped carbon quantum dots for enhancing fluorescence sensing of trace Hg2+. Phys. Chem. Chem. Phys. 2023, 25, 28230–28240. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  51. Meng, A.; Zhang, Y.; Wang, X.; Xu, Q.; Li, Z.; Sheng, L.; Yan, L. Fluorescence probe based on boron-doped carbon quantum dots for high selectivity “on-off-on” mercury ion sensing and cell imaging. Colloids Surf. A 2022, 648, 129150. [Google Scholar] [CrossRef] [Scilit]
  52. Yan, X.; Rahman, S.; Rostami, M.; Tabasi, Z.A.; Khan, F.; Alodhayb, A.; Zhang, Y. Carbon Quantum Dot-Incorporated Chitosan Hydrogel for Selective Sensing of Hg2+ Ions: Synthesis, Characterization, and DFT. ACS Omega 2021, 6, 23504–23514. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  53. Shabbir, H.; Csapó, E.; Wojnicki, M. Carbon Quantum Dots: The Role of Surface Functional Groups and Proposed Mechanisms for Metal Ion Sensing. Inorganics 2023, 11, 262. [Google Scholar] [CrossRef] [Scilit]
  54. Yan, F.; Meng, T.; Xu, J.; Li, Y.; Fu, Y. Revolutionary carbon quantum dots and their applications: A theoretical computations perspective. Microchem. J. 2025, 212, 113392. [Google Scholar] [CrossRef] [Scilit]
  55. Cánchig, M.B.; López, F.; Morales-Navarro, Z.; Debut, A.; Vizuete, K.; Terencio, T.; Caetano, M.; Saucedo-Vázquez, J.P. Enhanced selectivity of carbon quantum dots for metal ion detection through surface modification by heteroatom doping: A study on optical properties and theoretical approach. Carbon Trends 2025, 18, 100445. [Google Scholar] [CrossRef] [Scilit]
  56. Gumathannavar, R.; More, R.; Lohar, A.; Kadam, M.; Shirolkar, M.M.; Jadhav, Y.; Koratkar, S. DFT-guided photostable chitosan-derived carbon quantum dots as colloidal antibacterial and bioimaging agents. Sci. Rep. 2026, 16, 2211. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  57. Dai, D.; Zhang, C.; Thuy, N.T.D.; Zhao, G.; Lu, W.; Fan, J. Strong Fluorescence Quenching of Carbon Dots by Mercury(II) Ions: Ground-State Electron Transfer and Diminished Oscillator Strength. Diam. Relat. Mater. 2022, 126, 109076. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.