Skip to Content
You are currently on the new version of our website. Access the old version .
SensorsSensors
  • Article
  • Open Access

7 November 2019

12 Pages

Determination of Picomolar Concentrations of Paraoxon in Human Urine by Fluorescence-Based Enzymatic Assay

,
,
,
,
,
and
1
Institute of Biochemistry and Cellular Biology – National Research Council (CNR), via Pietro Castellino 111, 80131 Naples, Italy
2
Institute of Food Safety, Animal Health and Environment “BIOR”, Lejupes street 3, LV-1076 Riga, Latvia
3
Institute of Genetics and Biophysics “Adriano Buzzati Traverso”–National Research Council (CNR), via Pietro Castellino 111, 80131 Naples, Italy
*
Authors to whom correspondence should be addressed.
This article belongs to the Special Issue Optical and Fluorescent Sensors for Environment

Abstract

Organophosphate (OP) pesticides are widely used in the agricultural field and in the prevention of pest infestation in private and public areas of cities. Despite their unquestionable utility, several of these compounds demonstrate toxic effects to the environment and human health. In particular, the occurrence of some organophosphate pesticides is correlated to the incidence of nervous system disorders, especially in children. The detection of pesticide residues in the human body represents an important task to preserve human health. In our work we propose the use of esterase-based biosensors as a viable alternative to the expensive and time-consuming systems currently used for their detection in human fluids. Using the esterase-2 activity, coupled with a fluorescence inhibition assay, we are able to detect very low concentration levels of diethyl (4-nitrophenyl) phosphate (paraoxon) in the range of the femtomole (fmol). Method robustness tests indicate the stability of esterase-2 in a diluted solution of 4% human urine, and we are able to accurately determine concentration levels of paraoxon in the range from 0.1 to 2 picomoles (pmol). The system sensitivity for OP detection is calculated at 524 ± 14.15 fmol of paraoxon recognized at 10% of inhibition, with an estimated limit of quantification of 262 ± 8.12 pmol mL−1. These values are comparable with the most recent analysis methods based on mass spectrometry carried out on human samples for pesticide detection. This research represents a starting point to develop cheap and fast testing methods for a rapid screening of toxic substances in human samples.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.