Abstract
Understanding the relationship between the structure of electrospun coatings and their electrochemical behaviour is important for designing corrosion-resistant surfaces for biomedical alloys. In this work, electrospun polycaprolactone (PCL) and polycaprolactone–bovine serum albumin (PCL–BSA) coatings were deposited on TiZr alloy substrates to examine how coating morphology affects electrochemical behaviour in simulated body fluid (SBF). The incorporation of BSA produced coatings with a broader fibre diameter distribution and a less uniform fibrous network than pristine PCL coatings. These changes were accompanied by lower polarization resistance, higher corrosion current densities and a more pronounced evolution of the impedance response. The results suggest that structural heterogeneity provides a better explanation for the observed electrochemical behaviour than apparent wettability alone. Fibre morphology and structural heterogeneity should be considered together when designing electrospun coatings for biomedical applications.
1. Introduction
The surface of a metallic implant plays a key role in its long-term performance under physiological conditions, influencing both electrochemical stability and the biological response of the surrounding tissue [1,2,3]. Titanium-based alloys, particularly TiZr alloys, are attractive biomaterials because they combine favorable mechanical properties, corrosion resistance and excellent biocompatibility [4,5,6]. The importance of evaluating the corrosion behaviour of metallic biomaterials under simulated physiological conditions is also highlighted by studies investigating the stability and electrochemical response of surface oxide films on dental alloys [7]. Despite these advantages, the long-term performance of TiZr implants remains strongly dependent on their surface physicochemical characteristics. Surface modification has therefore become an important strategy for improving implant performance by balancing electrochemical stability with biological functionality [8,9]. Among the different surface modification strategies, electrospinning enables the fabrication of fibrous coatings with a high surface area, tunable morphology and controllable surface properties. These characteristics make electrospun coatings particularly attractive for biomedical applications. Polycaprolactone (PCL) is one of the most widely investigated biodegradable polymers for such coatings because it combines biocompatibility, chemical stability and excellent electrospinning processability [10,11]. In addition, the incorporation of bioactive compounds into electrospun polymer matrices has been explored as an effective approach to modify both the biological and physicochemical properties of the coating [12,13]. Protein incorporation represents one approach to further tailoring the properties of electrospun coatings. Proteins can improve the biological functionality of polymeric matrices while also influencing the electrospinning process and the resulting fibre morphology [14,15].
Among the proteins investigated for biomedical applications, bovine serum albumin (BSA) has attracted considerable interest because of its excellent biocompatibility and widespread use as a model protein [16,17]. The incorporation of proteins may therefore modify not only the biological functionality of electrospun coatings but also their structural characteristics, thereby influencing protein adsorption, cell response, and the overall interaction of the coating with the physiological environment [17,18].
Surface wettability, commonly evaluated by static water contact angle measurements, is frequently discussed in relation to the barrier properties and corrosion behaviour of polymer coatings. Hydrophobic surfaces are often associated with improved corrosion resistance because their lower affinity for aqueous media may delay electrolyte spreading and reduce contact between the electrolyte and the underlying substrate [19,20]. Consequently, electrochemical reactions may be slowed when the coating acts as an effective barrier. However, in electrospun fibrous coatings, wettability represents only one aspect of the surface response. Their electrochemical behaviour is also influenced by fibre morphology, structural organization, coating continuity and electrolyte accessibility through the fibrous network [20,21,22]. These effects are consistent with the broader principles governing organic protective coatings, where permeability to water and ionic species and their access to the coating/substrate interface are closely related to corrosion protection [23].
Furthermore, static contact angle measurements are themselves affected not only by surface chemistry but also by surface texture and topography. As a result, they may not fully describe the wetting behaviour of heterogeneous fibrous coatings or adequately predict their electrochemical performance [19,20,24]. Consequently, the electrochemical performance of electrospun fibrous coatings should be considered in terms of the combined effects of surface wettability and coating architecture rather than either factor alone.
Despite the increasing interest in electrospun polymeric coatings for biomedical metallic substrates, the interplay between protein-induced changes in fibrous architecture, surface wettability, and electrochemical behaviour remains insufficiently understood. In particular, establishing how these interconnected characteristics evolve upon BSA incorporation is relevant for distinguishing the contribution of surface chemistry from that of coating structural organization. The present study therefore addresses these relationships through a complementary morphological, physicochemical, mechanical, and electrochemical characterization of PCL and PCL–BSA fibrous coatings deposited on TiZr alloy.
2. Materials and Methods
2.1. Materials
An equiatomic Ti–50 at.% Zr alloy (hereafter denoted as TiZr) was used as the substrate material in the form of plates with dimensions of 20 mm × 20 mm × 2 mm.
Polycaprolactone pellets (PCL, Sigma-Aldrich, St. Louis, MO, USA), chloroform (CHCl3, 99%, Carl Roth, Karlsruhe, Germany), dimethyl sulfoxide (DMSO, 99.5%, Carl Roth, Germany), and bovine serum albumin (BSA, Merck KGaA, Darmstadt, Germany) were used for the preparation of electrospun coatings.
Simulated body fluid (SBF) was prepared using analytical-grade reagents (Sigma-Aldrich) and ultrapure water (Millipore Direct-Q 3UV system, 18.2 MΩ·cm), according to the Kokubo protocol [25]. The resulting composition has the following concentrations (g/L): 7.996 (NaCl), 0.35 (NaHCO3), 0.224 (KCl), 0.228 (K2HPO4∙3H2O), 0.304 (MgCl2∙6H2O), 0.278 (CaCl2), 0.07 (Na2SO4), and 6.056 ((CH2OH)3CNH2). The pH of SBF was adjusted to 7.40 with HCl (1 M) at 36.5 °C using a thermostat, in accordance with the cited protocol.
2.2. Procedures
2.2.1. Preparation of TiZr Samples
Prior to coating deposition, TiZr alloy samples were mechanically polished using silicon carbide (SiC) abrasive papers with progressively increasing grit sizes from P800 to P4000 [26] (FEPA standard). The polishing process was performed under running water to ensure a uniform surface finish.
Following mechanical polishing, the samples were ultrasonically cleaned in acetone, ethanol, and distilled water for 10 min each to remove organic and particulate contaminants. All cleaning steps were carried out at room temperature using fresh solvents. After cleaning, the samples were dried in air under ambient conditions prior to further processing.
2.2.2. Preparation of Electrospun Fibrous Coatings
The PCL solution (10% w/v) was prepared by dissolving PCL pellets in a CHCl3/DMSO solvent mixture (3:1, v/v) under magnetic stirring for 1 h until complete dissolution.
For the preparation of composite coatings, BSA (3% w/v, calculated relative to the final volume of the electrospinning formulation) was added to the PCL solution and homogenized under identical conditions. The resulting mixture remained homogeneous during the entire electrospinning process.
Electrospinning was carried out using a syringe pump with a flow rate of 0.5 mL/h and a high-voltage power supply operated at 18 kV. The needle-to-collector distance was maintained at 18 cm, and the deposition time was 1 h. The process was conducted in a climatized room at a temperature of 22 ± 1 °C, and a relative humidity of 40 ± 5%.
The selected electrospinning parameters were based on previously reported conditions for PCL and PCL–protein electrospinning systems, which have been shown to promote stable jet formation, adequate solvent evaporation, and continuous fibrous deposition [3]. All coatings were deposited onto TiZr substrates at ambient temperature.
2.3. Characterization Techniques
2.3.1. Scanning Electron Microscopy (SEM)
Scanning electron microscopy (SEM) was performed using a Hitachi TM4000plus microscope (Hitachi High-Tech Corp., Tokyo, Japan) operated at an accelerating voltage of 5 kV. Fibre diameter distribution was obtained from measurements of at least 100 randomly selected fibres from SEM micrographs using ImageJ software (version 1.8.0).
2.3.2. Adhesion Strength Measurements
The adhesion strength of the PCL and PCL–BSA coatings was evaluated by pull-off tests using a PosiTest AT-M adhesion tester (DeFelsko, Ogdensburg, NY, USA). The coated TiZr samples (14 mm diameter) were securely attached to the testing dolly. A constant, perpendicular pulling force was applied until failure occurred. The adhesion strength was calculated as the maximum force at failure divided by the area of the coated surface. For each composition, at least three independent measurements were performed, and the results are reported as mean value ± standard deviation. The failure mode (adhesive vs. cohesive) was assessed by post-test inspection of the fractured surfaces using Scanning Electron Microscopy (SEM).
2.3.3. Fourier-Transform Infrared Spectroscopy (FT–IR)
FT–IR spectra were recorded using a PerkinElmer Spectrum 100 spectrometer (PerkinElmer, Waltham, MA, USA) in the range of 4000–600 cm−1 with a spectral resolution of 4 cm−1.
2.3.4. Contact Angle Measurements
Static water contact angles of TiZr, TiZr–PCL, and TiZr–PCL–BSA samples were measured using a KSV CAM100 (KSV Instruments Ltd., Helsinki, Finland) contact angle measurement system. A 5 μL droplet of distilled water was deposited on the sample surface, and measurements were performed at three different locations. The reported values represent the average of three measurements.
2.3.5. Electrochemical Measurements
Electrochemical measurements were performed using a three-electrode electrochemical cell connected to a PalmSens4 potentiostat/galvanostat (PalmSens B.V., Houten, The Netherlands). All experiments were conducted in simulated body fluid (SBF) at room temperature in a three-electrode cell with an exposed working electrode area of 2 cm2, an Ag/AgCl (3 M KCl) as a reference electrode, and a platinum mesh as a counter electrode. Prior to electrochemical measurements, the open-circuit potential (OCP) was monitored for 30 min, during which a stable potential was reached.
Electrochemical impedance spectroscopy (EIS) measurements were performed at OCP over the frequency range from 105 to 10−2 Hz using a sinusoidal perturbation amplitude of 10 mV.
Potentiodynamic polarization measurements were carried out at a scan rate of 0.5 mV/s over the potential range from −250 mV to +250 mV relative to OCP, scanning from the chatodic to anodic direction. The corrosion potential (Ecorr) and corrosion current density (Icorr) were determined by Tafel extrapolation.
The corrosion rate (Vcorr), expressed in mm/year, was calculated from the corrosion current density (Icorr) using the relationship Vcorr = 0.00327 × Icorr × EW/ρ, where Icorr is expressed in µA/cm2, EW is the electrochemical equivalent weight of the TiZr alloy (17.39 g/equivalent), and ρ is its density (5.65 g/cm3). The equivalent weight was calculated based on the alloy composition.
Electrochemical measurements were performed in triplicate for each investigated condition, and the results are reported as mean ± standard deviation.
3. Results
3.1. Morphological Characterization of Electrospun Fibrous Coatings
SEM observations revealed the formation of continuous electrospun fibrous networks on both TiZr–PCL and TiZr–PCL–BSA coatings, although distinct differences in fibre morphology were observed after BSA incorporation (Figure 1). The TiZr–PCL coating exhibited a relatively homogeneous fibrous morphology composed of predominantly smooth, continuous fibres with only occasional minor spindle features. In contrast, incorporation of BSA preserved the continuous fibrous architecture but produced a more heterogeneous morphology characterized by larger variations in fibre diameter and the appearance of bead-on-string structures. Similar observations have been reported previously following protein incorporation into electrospun polymeric fibres, where broader fibre diameter distributions and bead-like features were also observed [17,27]. The coexistence of fibres with different diameters and localized bead-like features therefore indicates a less uniform organization of the PCL–BSA fibrous network, which may influence electrolyte accessibility within the fibrous coating.
Figure 1.
SEM micrographs of electrospun fibrous coatings deposited on TiZr substrates: (a) TiZr–PCL, and (b) TiZr–PCL–BSA.
Quantitative analysis of fibre diameters, based on measurements of at least 100 randomly selected fibres, confirmed the morphological differences observed in the SEM micrographs (Figure 2 and Figure S1). Fibre diameters were measured along bead-free fibre segments to ensure that the analysis reflected the actual fibre diameter. Bead regions were excluded from diameter measurements, while their presence was considered qualitatively in the morphological assessment of the fibrous network.
Figure 2.
Fibre diameter distribution histograms for (a) PCL, and (b) PCL–BSA fibrous coatings. Fibre diameter measurements were performed excluding bead regions in order to ensure consistent statistical comparison between samples.
The TiZr–PCL coating exhibited an average fibre diameter of 430 ± 40 nm, whereas incorporation of BSA increased the average fibre diameter to 775 ± 65 nm. Together with the presence of bead-on-string structures observed by SEM, this shift towards larger fibre diameters indicates a marked modification of the fibrous architecture and a less uniform morphology of the PCL–BSA coating.
The observed differences in fibre morphology and diameter distribution indicate that BSA incorporation modifies the structural organization of the electrospun coating. Although the surface SEM images provide qualitative information on the fibrous morphology, coating thickness, overall substrate coverage, and porosity were not quantitatively determined in the present study. Since these structural changes could also influence the mechanical integrity of the fibrous layer, the adhesion of the electrospun coatings to the TiZr substrate was evaluated using pull-off tests.
The TiZr–PCL and TiZr–PCL–BSA coatings exhibited average adhesion strengths of 4.5 ± 0.5 MPa and 4.2 ± 0.5 MPa, respectively. The comparable adhesion values suggest that BSA incorporation had only a limited effect on the interfacial adhesion of the electrospun coating to the metallic substrate. Moreover, the measured adhesion strengths are consistent with those reported for similar electrospun polymer-based coatings deposited on titanium alloys, with adhesion strengths of approximately 4 MPa reported for comparable systems [20].
Post-test SEM observations revealed complete removal of the electrospun coating from the TiZr substrate (see Supplementary Material Figure S2), whereas the detached coating fragments retained their continuous fibrous architecture.
This fracture pattern is consistent with adhesive failure at the coating/substrate interface, indicating that the measured pull-off strength primarily reflects the interfacial adhesion between the electrospun coating and the metallic substrate rather than cohesive failure within the fibrous layer.
Taken together, the SEM observations and pull-off measurements indicate that incorporation of BSA modifies the fibrous morphology while having only a limited effect on the measured adhesion strength of the coating to the TiZr substrate. Such differences in fibrous architecture may influence both the apparent wetting behaviour of the surface and the interaction of the coating with the electrolyte, with potential consequences for its electrochemical response. These aspects are discussed in the following sections.
3.2. FT-IR Analysis of TiZr Fibrous Coatings
FT–IR spectroscopy was used to examine the chemical composition of the electrospun coatings and to assess the incorporation of BSA into the PCL fibrous matrix. The corresponding spectra are presented in Figure 3. The spectrum of the TiZr–PCL coating exhibited the characteristic absorption bands of PCL. The bands at 2943 cm−1 and 2866 cm−1 correspond to the asymmetric and symmetric stretching vibrations of –CH2 groups, respectively, while the strong absorption band at 1723 cm−1 is attributed to the ester carbonyl (C=O) stretching vibration, consistent with the characteristic structure of PCL [28].
Figure 3.
FT–IR spectra of TiZr–PCL and TiZr–PCL–BSA fibrous coatings.
Following BSA incorporation, additional absorption bands characteristic of the protein component became evident in the TiZr–PCL–BSA coating. The broad band at approximately 3284 cm−1 corresponds to Amide A (N–H stretching), whereas the absorption bands located at 1644 cm−1 and 1532 cm−1 are assigned to the Amide I and Amide II vibrations, respectively. The assignment of these bands is consistent with the presence of BSA in the electrospun coating [29].
Partial overlap between PCL- and BSA-related absorption bands is observed in the TiZr–PCL–BSA spectrum, consistent with the simultaneous presence of both components in the electrospun fibrous matrix. Overall, the FT–IR spectra are consistent with the incorporation of BSA into the electrospun PCL coating. However, these measurements do not establish the spatial distribution of BSA within the fibres, its conformational state, or its potential release during immersion in SBF.
3.3. Electrochemical Impedance Spectroscopy (EIS)
Electrochemical impedance spectroscopy (EIS) was employed to evaluate the electrochemical response of uncoated and coated TiZr substrates during immersion in simulated body fluid (SBF). The Nyquist plots exhibited depressed capacitive semicircles without a clearly defined low-frequency diffusion-controlled region characteristic of Warburg behaviour. Accordingly, no Warburg element was included in the equivalent electrical circuits used for data fitting [30,31].
The equivalent electrical circuits were selected according to the impedance response observed in the Nyquist and Bode plots. The uncoated TiZr alloy exhibited a single dominant relaxation process associated with the passive oxide-covered metal/electrolyte interface and was fitted using a one-time-constant circuit consisting of the solution resistance (R1) in series with a parallel combination of the polarization resistance (R2) and a constant phase element (CPE). In contrast, the coated systems exhibited two relaxation processes, requiring a two-time-constant equivalent circuit to account for the contributions of the electrospun coating and the coating/substrate interface. For the coated systems, R1 represents the solution resistance, and R2 and C describe the coating-related response, whereas R3 and the CPE account for the electrochemical response at the coating/substrate interface. Constant phase elements were used to describe deviations from ideal capacitive behaviour [31]. The fitted R1 values varied among the investigated systems and immersion times, particularly for the TiZr–PCL coating. Although R1 is assigned to the solution resistance, its determination from equivalent-circuit fitting may be influenced by the separation of the high-frequency electrolyte response from other contributions to the impedance spectrum. Consequently, the observed differences in R1 cannot be attributed unambiguously to changes in the bulk SBF resistance and should be interpreted with caution.
The Nyquist plots of the uncoated TiZr alloy (see Supplementary Material Figure S3a) showed a progressive increase in impedance during immersion, while the Bode phase plots (see Supplementary Material Figure S3b) retained a single broad phase maximum throughout the exposure period consistent with one dominant relaxation process associated with the passive oxide-covered interface.
The fitted electrochemical parameters are summarized in Table 1. The polarization resistance (R2) increased from approximately 7.1 × 105 Ω at the beginning of immersion to 3.0 × 106 Ω after 336 h, while the CPE magnitude (Y0) showed a gradual decrease. The CPE exponent (n) remained relatively high and varied only slightly during the immersion period. Taken together, these changes indicate an increasingly resistive and predominantly capacitive interfacial response, consistent with the progressive stabilization of the passive surface during exposure to SBF [32,33].
Table 1.
EIS fitted parameters for uncoated TiZr.
The impedance spectra for TiZr–PCL showed significant changes compared to those of the uncoated alloy, reflecting the presence of the electrospun polymer layer (see Supplementary Material Figure S4). At the initial immersion stages, the coating exhibited high impedance and a pronounced capacitive response, indicating an effective barrier between the electrolyte and the metallic substrate. A similar capacitive barrier response has been reported for electrospun polymer coatings on titanium substrates, where the polymeric layer limited charge transfer and enhanced the electrochemical resistance of the coated surface [34]. As the immersion period increased, both the Nyquist and Bode plots exhibited significant changes, accompanied by variations in the fitted parameters (Table 2). The coating-related resistance (R2) exhibited a pronounced non-monotonic evolution, increasing from 48.91 Ω at 0 h to 1.20 × 105 Ω at 72 h, before decreasing to 14.60 Ω at 336 h. This behaviour may reflect time-dependent changes in electrolyte accessibility and ionic transport within the fibrous coating; however, the specific processes responsible for these variations cannot be established from the available electrochemical data alone. Despite some uneven changes during the immersion period, the interfacial resistance (R3) showed an overall decrease from 8.0 × 106 Ω at 0 h to 4.0 × 105 Ω after 336 h, indicating a reduction in the electrochemical barrier performance of the PCL coating during prolonged exposure to SBF.
Table 2.
EIS fitted parameters for TiZr–PCL.
Compared to the pure PCL coating, the TiZr–PCL–BSA system exhibited lower interfacial resistance (R3) during immersion (Figure S5 and Table 3), indicating a less effective electrochemical barrier. The coating-related resistance (R2) remained comparatively low throughout immersion (1.10–5.45 Ω), which may be associated with the greater wettability of the BSA-containing coating and the resulting accessibility of the fibrous network to the electrolyte. The interfacial resistance decreased markedly during the early stages of immersion, from 1.9 × 106 Ω at 0 h to a minimum of 4.2 × 104 Ω after 72 h. However, upon prolonged exposure, R3 stabilized at approximately 9.3 × 104 Ω after 336 h. In parallel, the CPE magnitude (Y0) increased from 1.32 × 10−5 to 7.94 × 10−5 over the same period, indicating a pronounced evolution of the electrochemical response at the coating/substrate interface during exposure to SBF.
Table 3.
EIS fitted parameters for TiZr–PCL–BSA.
Taking into account the observations from the SEM analysis, the faster evolution of the electrochemical response of the BSA-containing coating layer may be associated with its less uniform fibrous architecture, characterized by greater variations in fibre morphology and the presence of bead-on-string structures. Such morphological features could facilitate electrolyte access into the fibrous network, thereby reducing the effectiveness of the coating as an electrochemical barrier.
Overall, the EIS results demonstrate that BSA incorporation markedly modifies the electrochemical response of the electrospun coating, with the TiZr–PCL–BSA system exhibiting a faster decrease in interfacial resistance and a lower long-term barrier performance than the pristine PCL coating. Together with the SEM observations, these results suggest that the increased structural heterogeneity of the BSA-containing fibrous network may contribute to its less effective electrochemical barrier behaviour.
3.4. Potentiodynamic Polarization
Potentiodynamic polarization measurements were performed to further evaluate the electrochemical behaviour of the investigated systems during immersion in SBF and to complement the impedance analysis. The representative polarization curves are shown in Figure 4, while the electrochemical parameters obtained by Tafel extrapolation are summarized in Table 4.
Figure 4.
Potentiodynamic polarization curves for (a) TiZr, (b) TiZr–PCL, and (c) TiZr–PCL–BSA samples.
Table 4.
Tafel parameters of the samples.
The uncoated TiZr alloy exhibited relatively stable corrosion potentials together with low corrosion current densities throughout the immersion period, consistent with the high corrosion resistance associated with the passive behaviour of TiZr alloys [35]. The improved corrosion behaviour reported for titanium substrates coated with electrospun polymeric layers further demonstrates the potential of such coatings to modify the electrochemical response of the underlying metallic substrate [34]. In the present study, both electrospun coatings modified the polarization response compared with uncoated TiZr, although their electrochemical behaviour evolved differently during immersion in SBF.
Among the investigated coatings, TiZr–PCL exhibited the lowest corrosion current density and the highest polarization resistance during the initial immersion period, suggesting the most effective barrier effect. With increasing immersion time, the corrosion current density showed an overall increase, accompanied by a decrease in polarization resistance, indicating a progressive loss of barrier performance during exposure to SBF. Compared with the pristine PCL coating, the TiZr–PCL–BSA system showed a more pronounced initial deterioration of the polarization response, reaching its lowest polarization resistance and highest corrosion current density at 72 h of immersion. This was followed by a period of partial stabilization during prolonged exposure up to 336 h. This trend is consistent with the EIS results and further supports the conclusion that BSA incorporation modifies the electrochemical response of the electrospun coating. When considered together with the SEM results, this electrochemical behaviour suggests that the reduced barrier performance of the BSA-containing coating may be associated with its less uniform fibrous architecture. The presence of bead-on-string structures and greater morphological heterogeneity could facilitate electrolyte access within the fibrous network, thereby contributing to the faster evolution of its electrochemical response during immersion. Overall, the combined EIS and potentiodynamic polarization results demonstrate that BSA incorporation markedly modifies the electrochemical response of electrospun PCL coatings during immersion in SBF. Although the two techniques probe different aspects of the electrochemical behaviour, both consistently indicate a lower barrier performance of the PCL–BSA coating compared with pristine PCL, particularly during prolonged immersion.
3.5. Contact Angle Measurements and Implications for Surface–Electrochemical Behaviour
The surface wettability of TiZr-based systems was evaluated by static water contact angle measurements, and the obtained values are shown in Figure 5. The uncoated TiZr substrate exhibited a contact angle of 75.92 ± 3.40°, indicating a moderately hydrophilic surface characteristic of titanium-based alloys covered by a native oxide layer. After the deposition of PCL, the contact angle increased to 118.36 ± 1.90° due to the intrinsic hydrophobicity of polycaprolactone. Incorporation of BSA into the PCL matrix reduced the contact angle to 72.13 ± 4.30°, resulting in an apparent wettability comparable to that of the uncoated TiZr substrate. The increased apparent wettability of the BSA-containing coating is consistent with previous observations showing enhanced hydrophilicity of electrospun PCL fibrous surfaces in the presence of BSA [36].
Figure 5.
Static water contact angle measured for TiZr, TiZr–PCL and TiZr–PCL–BSA coatings.
Despite exhibiting similar apparent wettability, the TiZr substrate and the TiZr–PCL–BSA coating show significantly different electrochemical responses during immersion in SBF, indicating that static wettability alone is not sufficient to explain the electrochemical behaviour of electrospun fibrous coatings.
When considered together with the SEM observations, the electrochemical results suggest that the response of the coatings is influenced not only by surface wettability but also by the structural organization of the electrospun fibres. The incorporation of BSA resulted in a less uniform fibrous architecture, characterized by changes in fibre morphology and the presence of bead-on-string structures, while electrochemical measurements revealed a less effective barrier behaviour compared with the pristine PCL coating. These complementary observations indicate that surface characteristics and fibrous architecture contribute to the electrochemical performance of the investigated systems.
The present results highlight the importance of considering both surface properties and structural organization in the design of electrospun fibrous coatings for biomedical metallic substrates.
Although the incorporation of BSA into the electrospun PCL matrix significantly modified the apparent wettability of the coating, the electrochemical response was also strongly influenced by coating morphology and structural heterogeneity. These findings suggest that increasing the hydrophilicity of electrospun coatings does not necessarily lead to improved electrochemical stability. Changes in coating morphology and structural organization introduced by protein incorporation may simultaneously affect long-term interfacial behaviour under physiological conditions.
Therefore, the design of protein-functionalized electrospun coatings should consider not only surface chemistry but also the structural uniformity and long-term stability of the fibrous architecture during physiological exposure.
Balancing biofunctionality and electrochemical stability appears to be an important aspect in the development of electrospun fibrous coatings for biomedical applications.
4. Conclusions
Electrospun PCL and PCL–BSA coatings were successfully deposited on TiZr alloy substrates, producing continuous fibrous layers with comparable adhesion to the metallic substrate. Incorporation of BSA influenced the morphology of the electrospun coating, resulting in larger fibre diameters and a less uniform fibrous architecture characterized by the presence of bead-on-string structures.
Electrochemical investigations demonstrated that the pristine PCL coating provided a more effective barrier throughout the immersion period in simulated body fluid. In contrast, incorporation of BSA resulted in lower electrochemical resistance and higher corrosion current densities, indicating reduced barrier performance during prolonged exposure.
Static water contact angle measurements showed that BSA incorporation significantly increased the apparent wettability of the coating. However, despite exhibiting similar apparent wettability, the TiZr substrate and the TiZr–PCL–BSA coating displayed different electrochemical responses. When considered together with the SEM observations, these findings indicate that the electrochemical behaviour of the investigated coatings is influenced not only by surface wettability but also by the structural organization of the electrospun fibrous architecture.
Overall, the present study demonstrates that BSA incorporation into electrospun PCL coatings influences surface properties and coating morphology, as well as the electrochemical response during exposure to SBF. These findings highlight the importance of considering both surface characteristics and structural organization when designing protein-functionalized electrospun coatings for biomedical metallic substrates, particularly when sustained electrochemical barrier performance is required.
Supplementary Materials
The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/molecules31234299/s1: Figure S1. SEM micrographs of electrospun fibrous coatings deposited on TiZr substrates: (a) TiZr–PCL, and (b) TiZr–PCL–BSA. Figure S2. SEM micrograph of the TiZr metallic substrate after the pull-off test. Figure S3. Electrochemical impedance spectroscopy (EIS) results for TiZr (a) Nyquist plots, (b) Bode plots, and equivalent circuit. Figure S4. Electrochemical impedance spectroscopy (EIS) plots for TiZr–PCL: (a) Nyquist plots, (b) Bode plots, and equivalent circuit. Figure S5. Electrochemical impedance spectroscopy (EIS) plots for TiZr–PCL–BSA (a) Nyquist plots, (b) Bode plots, and equivalent circuit.
Author Contributions
Conceptualization, M.E.V. and D.I.; methodology, D.I.; software, M.E.V. and G.-O.B.; validation, D.I., G.-O.B.; formal analysis, M.E.V. and G.-O.B.; investigation, M.E.V. and G.-O.B.; resources, D.I.; data curation, D.I. and G.-O.B.; writing—original draft preparation, M.E.V. and D.I.; writing—review and editing, G.-O.B. and M.E.V.; visualization, D.I. and G.-O.B.; supervision, D.I. and G.-O.B. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Zhao, Q.; Ueno, T.; Wakabayashi, N. A review in titanium-zirconium binary alloy for use in dental implants: Is there an ideal Ti-Zr composing ratio. Jpn. Dent. Sci. Rev. 2023, 59, 28–37. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Voicu, M.E.; Stoian, A.B.; Demetrescu, I.; Ionita, D. Characterization of three surface treatments on TiZr—Coating properties and corrosion behavior. Coatings 2021, 11, 615. [Google Scholar] [CrossRef] [Scilit]
- Lukomska-Szymanska, M.; Radwanski, M.; Leski, M.; Khan, A.A.; Matinlinna, J.P. Advancements in Individual Dental Implants: A State-of-the-Art Review of Materials and Technologies. Materials 2026, 19, 1732. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Grandin, H.M.; Berner, S.; Dard, M. A review of titanium zirconium (TiZr) alloys for use in endosseous dental implants. Materials 2012, 5, 1348–1360. [Google Scholar] [CrossRef] [Scilit]
- Sherif, E.M. A comparative study on the corrosion of pure titanium and titanium–12%zirconium alloy after different exposure periods of time in sodium chloride solution. AIP Adv. 2024, 14, 035314. [Google Scholar] [CrossRef] [Scilit]
- Vardaki, M.; Prodana, P.; Stoian, A.B.; Ionita, D. Corrosion and bioactivity of a bioinspired coating on TiZr alloys. U.P.B. Sci. Bull. Ser. B 2018, 80, 209–218. [Google Scholar]
- Bassit, M.; Boudalia, M.; Bhoelai, M.; Bellaouchou, A.; Garcia, A.J.; Amin, H.M.A. Nanoscale evaluation of the dynamic interface and corrosion resistance of the chemically generated oxide film on dental vitallium alloy in simulated physiological solution. Surf. Interfaces 2025, 65, 106517. [Google Scholar] [CrossRef] [Scilit]
- Sharif, N.U.; Habibu, S.; Wang, H.; Veera Singham, G.; Huang, H.K.; Hu, C.; Zeng, G.S.; Tay, G.S. Advancing renewable functional coatings: Sustainable solutions for modern material challenges. J. Coat. Technol. Res. 2026, 23, 173–199. [Google Scholar] [CrossRef] [Scilit]
- Han, X.; Ma, J.; Tian, A.; Wang, Y.; Li, Y.; Dong, B.; Tong, X.; Ma, X. Surface modification techniques of titanium and titanium alloys for biomedical orthopaedics applications: A review. Colloids Surf. B Biointerfaces 2023, 227, 113339. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Voicu, M.E.; Demetrescu, I.; Dorobantu, A.; Enachescu, M.; Buica, G.-O.; Ionita, D. Interaction of Mg alloy with PLA electrospun nanofibers coating in understanding changes of corrosion, wettability, and pH. Nanomaterials 2022, 12, 1369. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Delgado-Pujol, E.J.; Alcudia, A.; Elhadad, A.A.; Rodríguez-Albelo, L.M.; Navarro, P.; Begines, B.; Torres, Y. Porous beta titanium alloy coated with a therapeutic biopolymeric composite to improve tribomechanical and biofunctional balance. Mater. Chem. Phys. 2023, 300, 127559. [Google Scholar] [CrossRef] [Scilit]
- Avcu, E.; Baştan, F.E.; Abdullah, H.Z.; Ur Rehman, M.A.; Yıldıran Avcu, Y.; Boccaccini, A.R. Electrophoretically deposited chitosan-based composite coatings for biomedical applications: A review. Prog. Mater. Sci. 2019, 103, 69–108. [Google Scholar] [CrossRef] [Scilit]
- Guo, Z.; Poot, A.A.; Grijpma, D.W. Advanced polymer-based composites and structures for biomedical applications. Eur. Polym. J. 2021, 149, 110388. [Google Scholar] [CrossRef] [Scilit]
- Rivero, P.J.; Redin, D.M.; Rodríguez, R.J. Electrospinning: A Powerful Tool to Improve the Corrosion Resistance of Metallic Surfaces Using Nanofibrous Coatings. Metals 2020, 10, 350. [Google Scholar] [CrossRef] [Scilit]
- Mehrnoush, S.; Labbaf, S.; Eslami, E.; Goli, M. Surface Performance of Bioactive Glass–Polycaprolactone–Gelatin Nanocomposite Coating on Anodized Ti6Al4V Alloy. Adv. Mater. Interfaces 2025, 12, e00179. [Google Scholar] [CrossRef] [Scilit]
- Höhn, S.; Braem, A.; Neirinck, B.; Virtanen, S. Albumin coatings by alternating current electrophoretic deposition for improving corrosion resistance and bioactivity of titanium implants. Mater. Sci. Eng. C 2017, 73, 798–807. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Won, J.J.; Nirmala, R.; Navamathavan, R.; Kim, H.Y. Electrospun core–shell nanofibers from homogeneous solution of poly(vinyl alcohol)/bovine serum albumin. Int. J. Biol. Macromol. 2012, 50, 1292–1298. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Barberi, J.; Spriano, S. Titanium and Protein Adsorption: An Overview of Mechanisms and Effects of Surface Features. Materials 2021, 14, 1590. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Al-Khateeb, A.; Al-Hassani, E.S.; Jabur, A.R. Metallic Implant Surface Activation through Electrospinning Coating of Nanocomposite Fiber for Bone Regeneration. Int. J. Biomater. 2023, 2023, 1332814. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ibrahim, S.W.; Hamad, T.I. Electrospun Nano-Barium Titanate/Polycaprolactone Composite Coatings on Titanium and Ti13Nb13Zr Alloy. Compos. Adv. Mater. 2023, 32, 1–17. [Google Scholar] [CrossRef] [Scilit]
- Zhang, D.; Wang, L.; Qian, H.; Li, X. Superhydrophobic Surfaces for Corrosion Protection: A Review of Recent Progresses and Future Directions. J. Coat. Technol. Res. 2016, 13, 11–29. [Google Scholar] [CrossRef] [Scilit]
- Karthega, M.; Pranesh, M.; Poongothai, C.; Srinivasan, N. Poly caprolactone/titanium dioxide nanofiber coating on AM50 alloy for biomedical application. J. Magnes. Alloys 2021, 9, 532–547. [Google Scholar] [CrossRef] [Scilit]
- Funke, W. Problems and progress in organic coatings science and technology. Prog. Org. Coat. 1997, 31, 5–9. [Google Scholar] [CrossRef] [Scilit]
- Peta, K.; Kubiak, K.J.; Brown, C.A. Multiscale geometric analysis of dynamic wettability on complex, fractal-like, anisotropic surfaces. Measurement 2026, 264, 120328. [Google Scholar] [CrossRef] [Scilit]
- Kokubo, T.; Takadama, H. How useful is SBF in predicting in vivo bone bioactivity? Biomaterials 2006, 27, 2907–2915. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- ISO 6344-3:2021; Coated Abrasives—Determination and Designation of Grain Size Distribution—Part 3: Microgrit Sizes P240 to P5000. International Organization for Standardization: Geneva, Switzerland, 2021; pp. 1–25. Available online: http://www.iso.org/standard/78219.html (accessed on 19 November 2026).
- Cruz-Maya, L.; Varesano, A.; Vineis, C.; Guarino, V. Comparative Study on Protein-Rich Electrospun Fibers for In Vitro Applications. Polymers 2020, 12, 1671. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Woodruff, M.A.; Hutmacher, D.W. The return of a forgotten polymer—Polycaprolactone in the 21st century. Prog. Polym. Sci. 2010, 35, 1217–1256. [Google Scholar] [CrossRef] [Scilit]
- Bozdag, M.; Urek, F.; Cesur, S.; Sahin, A.; Gunduz, O. Bovine Serum Albumin-Loaded Poly(vinyl alcohol)/Chitosan/Hydroxyapatite Electrospun Nanofibers for Bone Tissue Regeneration. J. Drug Deliv. Sci. Technol. 2025, 106, 106712. [Google Scholar] [CrossRef] [Scilit]
- Orazem, M.E.; Tribollet, B. Electrochemical Impedance Spectroscopy, 2nd ed.; John Wiley & Sons: Hoboken, NJ, USA, 2017. [Google Scholar]
- Trentin, A.; Pakseresht, A.; Duran, A.; Castro, Y.; Galusek, D. Electrochemical Characterization of Polymeric Coatings for Corrosion Protection: A Review of Advances and Perspectives. Polymers 2022, 14, 2306. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Prodana, M.; Stoian, A.B.; Ionita, D.; Brajnicov, S.; Boerasu, I.; Enachescu, M.; Burnei, C. In-Depth Characterization of Two Bioactive Coatings Obtained Using MAPLE on TiTaZrAg. Materials 2024, 17, 2989. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Geetha, M.; Singh, A.K.; Asokamani, R.; Gogia, A.K. Ti based biomaterials, the ultimate choice for orthopaedic implants—A review. Prog. Mater. Sci. 2009, 54, 397–425. [Google Scholar] [CrossRef] [Scilit]
- Ciarleglio, G.; Pagani, L.; Toto, E.; Laurenzi, S.; Santonicola, M.G. Electrospun PLA/nano-hydroxyapatite fiber coatings for improved corrosion protection of titanium implants. Surf. Interfaces 2025, 76, 107848. [Google Scholar] [CrossRef] [Scilit]
- Bolat, G.; Izquierdo, J.; Santana, J.J.; Mareci, D.; Souto, R.M. Electrochemical characterization of ZrTi alloys for biomedical applications. Electrochim. Acta 2013, 106, 432–439. [Google Scholar] [CrossRef] [Scilit]
- Tanes, M.L.; Xue, J.; Xia, Y. A General Strategy for Generating Gradients of Bioactive Proteins on Electrospun Nanofiber Mats by Masking with Bovine Serum Albumin. J. Mater. Chem. B 2017, 5, 5580–5587. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.