Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (116)

Search Parameters:
Keywords = solar air heater

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 9007 KB  
Article
CFD Analysis of the Thermal-Hydraulic Performance in a Fin Channel of a Solar Air Heater with Various Block Shapes
by Byeong-Hwa An, Eflita Yohana, Kwang-Am Moon and Hwi-Ung Choi
Processes 2026, 14(12), 2001; https://doi.org/10.3390/pr14122001 - 19 Jun 2026
Viewed by 213
Abstract
A solar air heater generates heated air using solar energy. This system has a relatively simple design, which reduces the initial cost and facilitates maintenance compared with other solar systems. However, its thermal conversion efficiency is limited by the poor thermal conductivity of [...] Read more.
A solar air heater generates heated air using solar energy. This system has a relatively simple design, which reduces the initial cost and facilitates maintenance compared with other solar systems. However, its thermal conversion efficiency is limited by the poor thermal conductivity of air. Previous studies have improved thermal efficiency by enhancing either the heat transfer area or the heat transfer coefficient, but most have applied only one of these approaches. In this work, a novel solar air heater with longitudinal fins and blocks, designed to simultaneously enhance the heat transfer area and heat transfer coefficient, is investigated for various block shapes (rectangular, forward-chamfered, backward-chamfered, and triangular blocks) utilizing computational fluid dynamics. Compared to the smooth fin channel, heat transfer is enhanced by a maximum of 1.61 times with the backward-chamfered block, while the corresponding enhancement factors for the rectangular, forward-chamfered, and triangular blocks are 1.52, 1.46, and 1.54, respectively. The thermo-hydraulic performance parameter, which simultaneously evaluates heat transfer augmentation and frictional penalty, further indicates that the backward-chamfered block is most effective at Reynolds numbers below 6000, while the rectangular block performs best above 9000. Full article
(This article belongs to the Special Issue Solar Energy and Heat Transfer Monitoring and Simulation)
Show Figures

Figure 1

23 pages, 7401 KB  
Article
A Flat Plate Solar Collector with a Backup Electric Heater for Heating Greenhouses in Egypt
by Reda Hassanien Emam Hassanien, Mohamed M. Ibrahim, Gang Pei and Eid N. Abd El Rahman
AgriEngineering 2026, 8(6), 225; https://doi.org/10.3390/agriengineering8060225 - 4 Jun 2026
Viewed by 502
Abstract
Providing optimal temperatures in greenhouses is essential for cultivating high-temperature-demand crops in winter. Therefore, this study aimed to investigate the feasibility of utilizing a flat plate solar collector (FPC) for heating greenhouses. A field experiment was conducted, complemented by simulations using the PolySun [...] Read more.
Providing optimal temperatures in greenhouses is essential for cultivating high-temperature-demand crops in winter. Therefore, this study aimed to investigate the feasibility of utilizing a flat plate solar collector (FPC) for heating greenhouses. A field experiment was conducted, complemented by simulations using the PolySun V2023.11 software. The FPC system comprised two collectors, each with an aperture area of 2.24 m2, connected to a 300 L hot water tank. The water tank had an internal electric backup heater (2 kW) and a thermostat to regulate the hot water temperature. The experiment consisted of two greenhouses, each with an area of 50 m2. The first unheated greenhouse (UHGH) was used as the control, while the second heated greenhouse (HGH) was heated by a closed-loop system comprising copper pipes installed along the internal perimeter. Results revealed that the FPC significantly increased air temperature by 2.7 °C, and reduced relative humidity by 9.7% in the HGH compared to the UHGH. Simulated results showed that the annual generated energy of the FPC was 4830 kWh with a reduction of CO2 emission by ≈2.9 tones. The average thermal efficiency of the FPC was 44%, with a payback period of 8.5 years. In conclusion, the FPC could protect plants from low temperatures in winter. Full article
(This article belongs to the Special Issue Solar Energy Integration into Controlled-Environment Agriculture)
Show Figures

Figure 1

29 pages, 9079 KB  
Article
Optimizing Thermal Comfort and Life Cycle Cost in High-Altitude Rural Housing Using NSGA-II and EnergyPlus
by Enrique Mejia-Solis, Tom Göransson and Björn Palm
Buildings 2026, 16(11), 2153; https://doi.org/10.3390/buildings16112153 - 28 May 2026
Viewed by 871
Abstract
Improving indoor thermal comfort in high-altitude rural housing remains a persistent challenge for low-income communities in the Peruvian Andes. This study evaluates the thermal performance of a standardized Sumaq Wasi modular dwelling in Langui (Cusco, Peru, 3969 m.a.s.l.) and proposes passive envelope modifications [...] Read more.
Improving indoor thermal comfort in high-altitude rural housing remains a persistent challenge for low-income communities in the Peruvian Andes. This study evaluates the thermal performance of a standardized Sumaq Wasi modular dwelling in Langui (Cusco, Peru, 3969 m.a.s.l.) and proposes passive envelope modifications that enhance comfort while preserving economic feasibility. A multi-objective optimization approach combining EnergyPlus simulations with the NSGA-II algorithm was applied to minimize total thermal discomfort (TDItotal), bedroom underheating (TDIUbedrooms), and 10-year life cycle costs (LCC). The calibrated model incorporated field measurements of indoor air temperatures. Global sensitivity analysis using Morris and Sobol methods identified ceiling thermal transmittance as the dominant contributor for TDItotal, and exterior wall solar absorptance as the driver of TDIUbedrooms. Optimization reduced TDItotal and TDIUbedrooms to 22% and 8% of the base case, requiring additional investments of USD 2347 and USD 1959, respectively, above the base case cost (USD 8100). Cost-neutral strategies, raising exterior wall solar absorptance to 0.9 and increasing the skylight-to-roof ratio (13.1%), reduced bedroom underheating to 30% of the base case and outperformed a scenario with two 400 W electric heaters. These results demonstrate that context-appropriate passive design can substantially improve comfort under severe climatic and financial constraints. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

31 pages, 3495 KB  
Article
Experimental Energy–Exergy–Economic–Environmental Assessment of a Curvature–Vortex-Intensified Serpentine Solar Air Heater for Low-Carbon Thermal Applications
by Deep Singh Thakur, Rajeev Kumar and Ravi Shankar
Energies 2026, 19(7), 1719; https://doi.org/10.3390/en19071719 - 1 Apr 2026
Viewed by 685
Abstract
Enhancing convective heat transfer in solar air heaters (SAHs) without disproportionate hydraulic penalty remains critical for decentralized low-carbon heating. This study experimentally investigates a serpentine-channel SAH equipped with distributed three-dimensional vortex generators under outdoor winter conditions. The configuration combines curvature-induced secondary motion with [...] Read more.
Enhancing convective heat transfer in solar air heaters (SAHs) without disproportionate hydraulic penalty remains critical for decentralized low-carbon heating. This study experimentally investigates a serpentine-channel SAH equipped with distributed three-dimensional vortex generators under outdoor winter conditions. The configuration combines curvature-induced secondary motion with distributed vortex generation to intensify absorber–air heat transfer. Experiments were conducted over a mass flow range of 0.012–0.061 kg s−1, corresponding to a Reynolds number range of 2.1 × 103–1.07 × 104, using a smooth duct as the reference configuration. The enhanced configuration achieved peak thermal efficiencies of 81.6–85.4%, compared with 65.8–67.7% for the smooth collector, while daily averaged efficiency increased from 56–59% to 71–75%. Although pressure drop increased, thermo-hydraulic performance remained superior across the investigated Reynolds number range. Exergy efficiency was consistently higher for the enhanced system and remained within optical limit constraints. Environmental assessment based on grid emission factor displacement indicates approximately 33% greater annual CO2 mitigation potential, corresponding to about 6.6 tonnes over a 20-year service life. The levelized cost of heating was estimated at 3.1–4.4 ₹ kWh−1. These results indicate that compound curvature–vortex transport intensification can improve thermal efficiency and increase carbon mitigation potential under realistic operating conditions. Full article
Show Figures

Figure 1

24 pages, 1309 KB  
Article
Experimental 3E Assessment of a PLC-Controlled Solar Air Heater with Adjustable Baffle
by Ayşe Bilgen Aksoy
Sustainability 2026, 18(2), 719; https://doi.org/10.3390/su18020719 - 10 Jan 2026
Viewed by 507
Abstract
This study presents an experimental 3E (energy–exergy–environmental) assessment of a PLC-controlled solar air heater (SAH) equipped with adjustable internal baffles. Unlike conventional passive systems, the proposed design enables active airflow regulation to maintain stable outlet temperatures of 54 °C and 60 °C, achieving [...] Read more.
This study presents an experimental 3E (energy–exergy–environmental) assessment of a PLC-controlled solar air heater (SAH) equipped with adjustable internal baffles. Unlike conventional passive systems, the proposed design enables active airflow regulation to maintain stable outlet temperatures of 54 °C and 60 °C, achieving rapid stabilization within 3–10 s under outdoor conditions. Experimental results show that increasing the baffle inclination significantly enhances convective heat transfer and thermal efficiency, while the friction factor remains primarily governed by the Reynolds number and exhibits minimal sensitivity to baffle angle. Exergy efficiency values remain relatively low (1.24–2.69%), and the sustainability index stays close to unity, reflecting the inherent thermodynamic limitations of low-temperature solar air heaters rather than deficiencies in system design. A regression-based airflow velocity model is developed to support fan-speed optimization and to clarify the trade-off between thermal enhancement and auxiliary power demand. Long-term projections based on regional solar data indicate that the proposed SAH can deliver approximately 20–22 MWh of useful heat and mitigate nearly 9 tons of CO2 emissions over a 20-year operational lifetime. Overall, the results demonstrate that PLC-assisted dynamic baffle control provides a flexible and effective approach for improving the performance and operational stability of solar air heaters for low-temperature drying applications. Full article
Show Figures

Figure 1

33 pages, 3160 KB  
Article
A Unified Optimization Approach for Heat Transfer Systems Using the BxR and MO-BxR Algorithms
by Ravipudi Venkata Rao, Jan Taler, Dawid Taler and Jaya Lakshmi
Energies 2026, 19(1), 34; https://doi.org/10.3390/en19010034 - 20 Dec 2025
Cited by 3 | Viewed by 1288
Abstract
In this work, three novel optimization algorithms—collectively referred to as the BxR algorithms—and their multi-objective versions, referred to as the MO-BxR algorithms, are applied to diverse heat transfer systems. Five representative case studies are presented: two single-objective problems involving a heat exchanger network [...] Read more.
In this work, three novel optimization algorithms—collectively referred to as the BxR algorithms—and their multi-objective versions, referred to as the MO-BxR algorithms, are applied to diverse heat transfer systems. Five representative case studies are presented: two single-objective problems involving a heat exchanger network and a jet-plate solar air heater; a two-objective optimization of Y-type fins in phase-change thermal energy storage units; and two three-objective problems involving TPMS–fin three-fluid heat exchangers and Tesla-valve evaporative cold plates for LiFePO4 battery modules. The proposed algorithms are compared with leading evolutionary optimizers, including IUDE, εMAgES, iL-SHADEε, COLSHADE, and EnMODE, as well as NSGA-II, NSGA-III, and NSWOA. The results demonstrated improved convergence characteristics, better Pareto front diversity, and reduced computational burden. A decision-making framework is also incorporated to identify balanced, practically feasible, and engineering-preferred solutions from the Pareto sets. Overall, the results demonstrated that the BxR and MO-BxR algorithms are capable of effectively handling diverse thermal system designs and enhancing heat transfer performance. Full article
(This article belongs to the Section J1: Heat and Mass Transfer)
Show Figures

Figure 1

23 pages, 6046 KB  
Article
Thermal Efficiency Enhancement of Solar Air Collector Integrated with an Electric Heater Using Experimental and Numerical Approaches
by Mohammed A. M. AL-Jaafari, Mehmet Özalp, Hasanain A. Abdul Wahhab, Cevat Özarpa and Hussein N. O. AL-abboodi
Sustainability 2025, 17(24), 10974; https://doi.org/10.3390/su172410974 - 8 Dec 2025
Cited by 1 | Viewed by 967
Abstract
Although numerous studies have investigated individual methods to improve the performance of solar air heaters (SAHs), such as flow obstruction barriers, porous media, nanofluids, and thermal energy storage units, the overall integration of these reinforcement strategies into a unified, sustainable system remains to [...] Read more.
Although numerous studies have investigated individual methods to improve the performance of solar air heaters (SAHs), such as flow obstruction barriers, porous media, nanofluids, and thermal energy storage units, the overall integration of these reinforcement strategies into a unified, sustainable system remains to be defined. The current study presents a hybrid solar air heating configuration that combines a solar air collector (SAC) with an electric air heater (EAH) powered by photovoltaic (PV) panels, aiming to stabilize outlet air temperature and enhance overall thermal efficiency. Experimental and numerical approaches were employed to evaluate the influence of barrier geometry (flat, trapezoidal, and V-groove) and airflow rate (53, 158, and 317 L/min) on system performance using three SAC models. Experimental results revealed that lower airflow rate promotes greater temperature rise (ΔT) due to longer air–surface contact, while V-groove barriers achieved the highest ΔT and collector efficiency among all configurations. At higher airflow rates, the absorbed energy factor Fc (τα) increased to approximately 0.73, whereas the heat loss factor FcU decreased, indicating reduced thermal losses and improved energy transfer. Model III demonstrated the most effective heat absorption, confirming its superior thermal design. The integrated SAC–EAH system exhibited improved overall efficiency, with the SAC functioning effectively as a preheating unit and the EAH sustaining thermal stability during variable solar conditions. Numerical results showed that the highest temperature difference occurs at the V-groove barriers at an air flow rate of 53 L/min. In contrast, the difference between inlet and outlet temperatures decreases across the remaining models, with reduced percentages of 11.8% and 12.7% for Model II and Model I, respectively. Numerical simulations ensured the experimental outcomes, showing close agreement with the temperature variation trends and validating the system’s enhanced thermal performance. Full article
(This article belongs to the Special Issue Energy and Environment: Policy, Economics and Modeling)
Show Figures

Figure 1

32 pages, 14943 KB  
Article
Effect of Subducting Baffle Structure in Solar Air Heaters: A CFD Insight into Thermo-Hydraulic Performance
by Beno Wincy Winsly, Prince Abraham Benjamin, Murugan Paradesi Chockalingam, Joseph Sekhar Santhappan, Rajendran Prabakaran and Sung Chul Kim
Energies 2025, 18(23), 6223; https://doi.org/10.3390/en18236223 - 27 Nov 2025
Cited by 2 | Viewed by 868
Abstract
Numerical analysis is an economically viable method for improving the performance of a thermal system without many trials. The numerical analysis reported in this paper serves to clarify the extent to which a newly designed subducting baffling structure impacts the performance of a [...] Read more.
Numerical analysis is an economically viable method for improving the performance of a thermal system without many trials. The numerical analysis reported in this paper serves to clarify the extent to which a newly designed subducting baffling structure impacts the performance of a solar air heater (SAH). The performance of different baffle shapes is evaluated through a two-dimensional Computational Fluid Dynamics (CFD) simulation in terms of the thermal (Nu), hydraulic (f), and thermo-hydraulic (THP) performances of the SAH. Moreover, the study is performed with different Reynolds numbers (Re) varying from 3000 to 18,000. The study investigates the parameters arm length (k), arm height (l), pitch (p), pitch angle (α), and arm angle (β) within the ranges of 40–60°, 140–160°, 0.03–0.07 m, 0.03–0.05 m, and 0.05–0.15 m, respectively. The results demonstrate that the assistance of a subducting baffle structure is more effective than a smooth arrangement. The SAH shows a maximum Nu and f of 101.23 and 0.97, respectively. The system with the best performance has revealed the highest THP of 0.798. The greatest intensification of heat transfer (Nu/Nus) and friction loss (f/fs) are 2.58 and 87.76, respectively. Full article
(This article belongs to the Section A: Sustainable Energy)
Show Figures

Figure 1

23 pages, 2524 KB  
Review
Comprehensive Review of Thermal and Thermohydraulic Performance in Solar Air Heaters with Advanced Artificial Roughness Geometries
by Rohit Singh and Ramadas Narayanan
Energies 2025, 18(23), 6157; https://doi.org/10.3390/en18236157 - 24 Nov 2025
Cited by 6 | Viewed by 1381
Abstract
This study provides a detailed review of the thermal and thermo-hydraulic performance of solar air heaters (SAHs) enhanced through the application of artificial roughness on the absorber plate. Various roughness geometries, such as wire ribs, V-shaped ribs, arc-shaped ribs, and rib-groove patterns, have [...] Read more.
This study provides a detailed review of the thermal and thermo-hydraulic performance of solar air heaters (SAHs) enhanced through the application of artificial roughness on the absorber plate. Various roughness geometries, such as wire ribs, V-shaped ribs, arc-shaped ribs, and rib-groove patterns, have been analysed to assess their influence on heat transfer enhancement and frictional behaviour. Findings from previous experimental and numerical studies reveal that the incorporation of artificial roughness can increase the Nusselt number by approximately 1.25 to 6.3 times and improve thermal efficiency by 20–35% when compared to smooth absorber plates. The review further highlights that the most effective performance occurs at a relative roughness height (e/D) between 0.02 and 0.05 and within a Reynolds number range of 10,000 to 18,000. Overall, the analysis confirms that artificial roughness is a simple, economical, and highly effective technique to enhance heat transfer and overall efficiency in solar air heater systems. Full article
Show Figures

Figure 1

22 pages, 2259 KB  
Article
Experimental and Numerical Investigation of a Novel Low-Cost Solar Air Heater with Large-Scale V-Shaped Fins to Enhance Heat Transfer
by Omayma Elakrout, Ons Ghriss, Abdallah Bouabidi and Maarten Vanierschot
Energies 2025, 18(20), 5503; https://doi.org/10.3390/en18205503 - 18 Oct 2025
Cited by 3 | Viewed by 1435
Abstract
This study investigates the performance of a novel, low-cost solar air heater equipped with large V-shaped fins using experiments and numerical simulations. The solar air heater consists of an absorber plate, a glass cover and airflow ducts. Its performance is evaluated under varying [...] Read more.
This study investigates the performance of a novel, low-cost solar air heater equipped with large V-shaped fins using experiments and numerical simulations. The solar air heater consists of an absorber plate, a glass cover and airflow ducts. Its performance is evaluated under varying fin configurations: finless and (a)symmetric V-shaped fins with four, six, and eight fins. Computational fluid dynamics simulations using the RNG k-epsilon and discrete ordinate models were validated by experimental findings, showing good agreement with minimal discrepancies between both. The experimental setup recorded a maximum air temperature of 55 °C, corresponding to a temperature rise of 33 °C from an inlet temperature of 22 °C, under an inlet air velocity of 2.7 m/s. Results demonstrate that increasing the number of fins significantly enhances heat transfer efficiency, with heat transfer rising from 134.35 W (finless) to 233.29 W (8 fins). The large-scale fins improved thermal performance significantly while still maintaining a low-pressure drop. Moreover, the fins are very low-cost to implement, in contrast to most heat transfer enhancements in solar air heaters, making this design a very budget-friendly solution. This study provides valuable insights into optimizing solar air heater systems, contributing to the advancement of solar heating solutions for a wide range of energy-efficient applications. Full article
(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
Show Figures

Figure 1

33 pages, 2775 KB  
Article
Sustainable Solar Panel Efficiency Optimization with Chaos-Based XAI: An Autonomous Air Conditioning Cabinet-Based Approach
by Ebru Akpinar, Fatma Papatya, Mehmet Das, Suna Yildirim, Bilal Alatas, Murat Catalkaya and Orhan E. Akay
Sustainability 2025, 17(16), 7514; https://doi.org/10.3390/su17167514 - 20 Aug 2025
Cited by 2 | Viewed by 1784
Abstract
This study introduces a climate chamber developed to evaluate the performance of photovoltaic (PV) and solar air heater (SAH) panels based on 12 months of climate data specific to the province of Antalya. In the test environment, the temperature can be controlled between [...] Read more.
This study introduces a climate chamber developed to evaluate the performance of photovoltaic (PV) and solar air heater (SAH) panels based on 12 months of climate data specific to the province of Antalya. In the test environment, the temperature can be controlled between −5 and +50 °C, relative humidity between 10% and 90%, irradiance between 0 and 1500 W/m2, and wind speed between 0 and 25 m/s. Experimental data revealed that PV panels achieved the lowest electricity production of 19.21 W in December and the highest of 73.47 W in June, while SAH panels reached an outlet temperature of 31.12 °C in July. As solar radiation increased, panel efficiency rose proportionally; however, an increase in relative humidity negatively impacted efficiency. The panel surface temperature increased from 16.86 °C in January to 39.33 °C in July. The original aspect of this study is the proposal and adaptation of chaos-integrated optimization-based explainable artificial intelligence (XAI) methods instead of classical regression-based models. These models have enabled the development of transparent, understandable, and interpretable rules based on environmental parameters, such as temperature, relative humidity, radiation, and airspeed, that affect panel performance. The methods used in this study make significant contributions to sustainable energy. In particular, the climate control test chamber developed to increase and optimize the efficiency of solar panels enables the investigation of the effects of environmental parameters on panel performance under realistic conditions, thereby facilitating the more effective use of renewable energy sources. Additionally, the use of chaos-integrated optimization-based explainable artificial intelligence (XAI) methods provides reliable, transparent, and understandable decision support models for the design and management of energy systems. This method promotes the adoption of renewable energy technologies, reduces dependence on fossil fuels, lowers carbon emissions, and supports long-term environmental sustainability. Full article
(This article belongs to the Section Energy Sustainability)
Show Figures

Figure 1

14 pages, 3515 KB  
Article
Analysis of Heat Transfer and Fluid Flow in a Solar Air Heater with Sequentially Placed Rectangular Obstacles on the Fin Surface
by Byeong-Hwa An, Kwang-Am Moon, Seong-Bhin Kim and Hwi-Ung Choi
Energies 2025, 18(14), 3811; https://doi.org/10.3390/en18143811 - 17 Jul 2025
Cited by 4 | Viewed by 1394
Abstract
A solar air heater (SAH) converts solar energy into heated air without causing environmental pollution. It features a low initial cost and easy maintenance due to its simple design. However, owing to air’s poor thermal conductivity, its thermal efficiency is relatively low compared [...] Read more.
A solar air heater (SAH) converts solar energy into heated air without causing environmental pollution. It features a low initial cost and easy maintenance due to its simple design. However, owing to air’s poor thermal conductivity, its thermal efficiency is relatively low compared to that of other solar systems. To improve its thermal performance, previous studies have aimed at either enlarging the heat transfer surface or increasing the convective heat transfer coefficient. In this study, a novel SAH with fins and sequentially placed obstacles on the fin surface—designed to achieve both surface extension through a finned channel and enhancement of the heat transfer coefficient via the obstacles—was investigated using computational fluid dynamics analysis. The results confirmed that the obstacles enhanced heat transfer performance by up to 2.602 times in the finned channel. However, the obstacles also caused a pressure loss. Therefore, the thermo-hydraulic performance was discussed, and it was concluded that the obstacles with a relative height of 0.12 and a relative pitch of 10 yielded the maximum THP values among the investigated conditions. Additionally, correlations for the Nusselt number and friction factor were derived and predicted the simulation values with good agreement. Full article
(This article belongs to the Special Issue Solar Energy and Resource Utilization—2nd Edition)
Show Figures

Figure 1

25 pages, 26783 KB  
Article
Performance Enhancement of a Solar Air Heater Equipped with a Tree-like Fractal Cylindrical Pin for Drying Applications: Tests Under Real Climatic Conditions
by Chotiwut Prasopsuk, Kittiwoot Sutthivirode and Tongchana Thongtip
Energies 2025, 18(9), 2230; https://doi.org/10.3390/en18092230 - 27 Apr 2025
Cited by 7 | Viewed by 2027
Abstract
This paper reports the improved thermal and drying performance of a solar air heater powered by real solar irradiance and equipped with a tree-like fractal-based cylindrical pin (SAH-TFCP) as a turbulator for drying applications. The main purpose of this work is to demonstrate [...] Read more.
This paper reports the improved thermal and drying performance of a solar air heater powered by real solar irradiance and equipped with a tree-like fractal-based cylindrical pin (SAH-TFCP) as a turbulator for drying applications. The main purpose of this work is to demonstrate the SAH-TFCP’s improvement potential based on its thermal and drying performance as compared with a conventional solar air heater based on a flat-plate absorber (SAH-FP). The test was implemented based on solar time from 8:30 to 17:30 under Thailand’s climatic conditions at a latitude angle of 14° and a longitude angle of 100°. Turmeric slices were used to evaluate the SAH’s drying performance. The thermal efficiency, moisture content wet basis (MCwb), drying rate (DR), and drying efficiency were measured as parameters of interest to assess the improvement potential of the SAH-TFCP over the SAH-FP. The results indicate that the SAH-TFCP provides better thermal and drying performance than the SAH-FP. A higher flow rate yields a higher thermal efficiency and a greater improvement potential. The improvement potential is around 44–85%. The drying efficiency of the SAH-TFCP is always higher than that of the SAH-FP and has an improvement potential of 32–44%, depending on the airflow rate. Full article
Show Figures

Figure 1

18 pages, 5895 KB  
Article
Numerical Simulation and Optimization of a Chevron-Type Corrugated Solar Air Heater
by Umar Fahed Alqsair
Energies 2025, 18(7), 1821; https://doi.org/10.3390/en18071821 - 4 Apr 2025
Cited by 6 | Viewed by 1396
Abstract
In the present study, a numerical simulation and optimization combined approach is applied to investigate the thermal performance of a solar air heater (SAH). Numerical simulation of the solar air heater is performed based on computational fluid dynamics (CFDs) via ANSYS Fluent 2023R1 [...] Read more.
In the present study, a numerical simulation and optimization combined approach is applied to investigate the thermal performance of a solar air heater (SAH). Numerical simulation of the solar air heater is performed based on computational fluid dynamics (CFDs) via ANSYS Fluent 2023R1 software. The solar air heater includes a corrugated absorber plate with a Chevron-type design. Present study was conducted in Al-Kharj, Saudi Arabia on August 15. The optimization process is used to enhance the thermal efficiency of the solar system. In the optimization process, several geometric parameters of the solar air heater, including the wave height and pitch length of the corrugated absorber plate and the height of the airflow channel under the absorber plate, have been evaluated. The wave height is between 10 and 20 mm, the pitch length is between 50 and 90 mm, and the channel height is between 70 and 90 mm. Therefore, the design of experiment (DOE) and response surface methodology (RSM) are utilized to estimate temperature rise and thermal efficiency. The thermal analysis shows that increasing the wave height, decreasing the pitch length, and shortening the channel height enhances both the temperature rise coefficient and the thermal efficiency. Full article
(This article belongs to the Section A: Sustainable Energy)
Show Figures

Figure 1

18 pages, 3782 KB  
Article
Thermal Performance and Cost Assessment Analysis of a Double-Pass V-Trough Solar Air Heater
by Eduardo Venegas-Reyes, Naghelli Ortega-Avila, Yuridiana Rocio Galindo-Luna, Jonathan Ibarra-Bahena, Erick Cesar López-Vidaña and Ulises Dehesa-Carrasco
Clean Technol. 2025, 7(1), 27; https://doi.org/10.3390/cleantechnol7010027 - 18 Mar 2025
Cited by 5 | Viewed by 3430
Abstract
Solar air heating systems offer an effective alternative for reducing greenhouse gas emissions at a profitable cost. This work details the design, construction, and experimental evaluation of a novel double-pass V-trough solar air heater with semicircular receivers, which was built with low-cost materials [...] Read more.
Solar air heating systems offer an effective alternative for reducing greenhouse gas emissions at a profitable cost. This work details the design, construction, and experimental evaluation of a novel double-pass V-trough solar air heater with semicircular receivers, which was built with low-cost materials readily available in the Mexican market. Thermal performance tests were conducted in accordance with the ANSI-ASHRAE 93-2010 standard. The results indicated a peak collector efficiency of 0.4461 and total heat losses of 8.8793 W/(m2 °C), with an air mass flow rate of 0.0174 kg/s. The instantaneous thermal efficiency varied between 0.2603 and 0.5633 with different air flow rates and an inlet air temperature close to the ambient temperature. The outlet air temperature reached 70 °C, making it suitable for dehydrating fruits or vegetables at competitive operating costs. Additionally, a second-law analysis was carried out, and the exergy efficiency was between 0.0037 and 0.0407. Finally, a Levelized Cost of Energy analysis was performed, and the result was USD 0.079/kWh, which was 31% lower than that of a conventional electric air heater system. Full article
Show Figures

Figure 1

Back to TopTop