Abstract
As one of the three fundamental modes of heat transfer, thermal radiation has long attracted interest due to its independence from a medium and its strong temperature dependence. In extreme environments such as deep space exploration and cryogenic engineering, thermal radiation often becomes the dominant heat transfer mechanism. Consequently, the radiative properties of materials are crucial for achieving precise thermal control, directly influencing the thermal stability and overall performance of advanced systems, including space probes, cryogenic devices, and superconducting components operating under high-vacuum and low-temperature conditions. This paper provides a systematic review of the physical mechanisms, key factors affecting emissivity, major measurement methods, and technological developments related to material radiative properties at cryogenic temperatures. Particular attention is given to experimental methods and techniques describing material radiative behavior, along with a comparative analysis of the suitability of different measurement techniques for cryogenic applications. Finally, the study highlights the significant practical value of this research for fields such as aerospace, precision electronics, and cryogenic instrumentation, aiming to offer insights for optimizing cryogenic thermal management and guiding the design of novel functional materials.
1. Introduction
1.1. Importance of Thermal Radiation at Cryogenic Temperatures
As is well known, thermal management plays a significant role in fields such as aerospace, military technology and precision instruments. Among the three fundamental modes of heat transfer, thermal radiation has garnered considerable attention in thermal management [1,2,3,4,5], particularly under extreme conditions. This is due to its strong temperature dependence and ability to transfer heat independently of a medium. Under conditions of cryogenic temperatures and high vacuum, conventional heat transfer mechanisms such as convection and conduction are greatly suppressed or even completely eliminated, leaving thermal radiation as the dominant pathway for heat exchange [6,7].
Furthermore, as application temperatures extend to ever lower ranges, it is extremely importance to accurately study the radiation properties of materials at cryogenic temperatures. This significantly contributes to thermal field stability and performance enhancement in various cryogenic systems, such as space technology [8,9,10], cryogenic electronics [11], quantum computing [12] and advanced thermal management systems [3,13].
For example, the spectral emissivity and absorptivity of materials at cryogenic temperatures directly influence the design accuracy of spacecraft thermal control systems, thereby affecting the operational stability and service life of in-orbit equipment. Specifically, space probes frequently employ high-emissivity coatings to maintain instruments within optimal temperature ranges [14,15,16], whereas cryogenic optical sensors and space calibration systems require high-absorptivity blackbody coatings to ensure accurate signal detection and measurement [17]. At the same time, a coating is applied around the optical sensor and its components to prevent interference from reflected light.
Therefore, systematic investigation of material radiative properties under cryogenic conditions not only improves thermal management efficiency but also provides a theoretical foundation and design guidance for cryogenic engineering and the development of next-generation functional materials.
1.2. Characterization of Material Thermal Radiative Properties
In the study of material radiative properties, emissivity is a fundamental parameter used to characterize a material’s ability to emit thermal radiation. Emissivity is generally classified into three main types: directional emissivity, spectral emissivity, and hemispherical total emissivity [18]. The classification of emissivity is depicted in Figure 1. Specifically, directional emissivity refers to the ratio of a material’s radiative power, integrated over all wavelengths in a given direction, to that of a blackbody at the same temperature. Spectral emissivity describes the ratio of a material’s radiative intensity at a specific wavelength and direction to the corresponding blackbody intensity at the same temperature and wavelength. Hemispherical total emissivity is defined as the ratio of the total radiative energy emitted by a material over all wavelengths and directions within a hemisphere to that of a blackbody under identical temperature conditions. In most macroscopic heat transfer scenarios, emissivity values lie between 0 and 1, consistent with Planck’s blackbody radiation theory [19].
Figure 1.
Classification of emissivity and absorptivity. The illustration in the figure uses the emissivity as an example. The yellow region denotes the hemispheric total emissivity. The blue region denotes the directional emissivity. The green region denotes the hemispheric spectral emissivity.
However, when the spacing between radiating surfaces becomes comparable to the characteristic thermal radiation wavelength, the classical Planck law ceases to be valid, and near-field effects become significantly enhanced [20,21]. In such cases, theoretical frameworks such as fluctuation electrodynamics are required to accurately describe the radiative behavior [22]. The present discussion is therefore limited to thermal radiation under far-field and macroscopic conditions.
1.3. Factors Affecting Emissivity
The radiative properties of material surfaces are governed by multiple physical and geometric factors. Mathematically, emissivity can be expressed as a multivariable function:
where is the absolute temperature, is the radiation wavelength, and are the emission angles. For most metallic materials, emissivity decreases with decreasing temperature. This behavior is primarily attributed to the reduction in electron–phonon scattering at low temperatures, which increases the electrical conductivity and consequently decreases the absorptivity—and hence emissivity—of metals. For example, Kralik et al. [6] investigated the radiative characteristics of chemically polished pure aluminum sheets (99.5% purity) over the temperature range 20 K ≤ T ≤ 320 K, reporting that the emissivity at T = 20 K is less than one-quarter of its value at T = 320 K. In addition to temperature, both wavelength and radiation direction strongly influence emissivity [23,24,25]. These dependencies arise from variations in the material’s optical constants (n, k) with wavelength and the angular dependence of Fresnel reflection coefficients. Yuan et al. [26] measured the spectrally resolved directional emissivity of silicon carbide at T = 213 K, revealing pronounced wavelength-dependent behavior. At a fixed wavelength, emissivity was observed to increase as the viewing angle decreased, consistent with reduced reflectivity near normal incidence.
In addition to intrinsic material properties, surface microstructure and morphology strongly affect emissivity. Surface roughness, the most common micro-geometric characteristic, can significantly modify a material’s radiative behavior [27,28,29]. Musilova et al. [30,31] systematically examined the emissivity of metal samples subjected to different surface treatments, including mechanical polishing, chemical polishing, precision turning, sandblasting, grinding, etching, and gold plating, while also considering the effects of material purity and surface aging. These results highlight that even for materials of identical composition, preparation methods and surface structure can lead to substantial variations in emissivity.
Therefore, the emissivity of materials at low temperatures is jointly determined by composition, temperature, wavelength, radiation direction, and surface microstructure. Accurate measurement of these properties under cryogenic conditions is not only essential for engineering applications, such as spacecraft thermal control, cryogenic electronics, and superconducting systems, but also provides a theoretical foundation for understanding surface radiation behavior in real operating conditions.
2. Techniques for Measuring Emissivity
Accurate determination of a material’s emissivity requires a systematic understanding of measurement principles. Measurement techniques are broadly categorized into direct and indirect methods [18,32]. The measurement methods for emissivity are shown in Figure 2. Direct methods determine emissivity by detecting the energy radiated by the sample or the thermal response it induces. Calorimetric approaches infer emissivity from temperature changes under steady-state or transient thermal equilibrium, while radiometric methods directly collect radiant energy at specific temperatures and wavelengths using radiometers or spectrometers, comparing it to blackbody emission under identical conditions. Indirect methods often rely on reflection measurements, which calculate emissivity via Kirchhoff’s law by measuring surface reflectance, with absorptivity inferred as the complement of reflectance under negligible transmission.
Figure 2.
Measurement methods for emissivity.
2.1. Calorimetric Methods
As one of the most widely used techniques for emissivity testing, calorimetry can be further classified into steady-state calorimetry and transient calorimetry, depending on the heat-flow conditions during measurement. The steady-state calorimetric method is based on a one-dimensional heat conduction model. Its core principle is to convert the radiative heat transfer from the radiator (sample end, TR) to the absorber (typically a high-absorptivity blackbody, TA) into a steady-state heat conduction process through a calorimeter rod of known thermal properties, which transfers heat from the absorber to a reference end (a heat sink maintained at constant temperature, TS). Before measurement, the calorimeter rod must be calibrated to establish the relationship between heat flux Q and the temperature difference between its end (TA − TS), expressed as [6,33]:
During formal testing, once the system reaches thermal equilibrium, the heat flux Q is determined by measuring the steady-state temperature difference (TA − TS). This value corresponds to the net radiative heat flux emitted by the sample (TR) toward the absorber (TA). From this measurement, the hemispherical total emissivity of the sample surface can be calculated. The thermal equilibrium of the radiator and absorber ends during steady-state testing can be described by the following energy-balance equations:
where Q is the net radiative heat transfer from the radiator to the absorber, is the hemispherical emissivity of the radiator surface, is the Stefan–Boltzmann constant [34], A is the effective radiating surface area of the radiator, TR is the steady-state temperature of the radiator and TA is the steady-state temperature of the absorber. According to Equation (2), once the radiator and absorber reach thermal equilibrium, the radiative heat transfer Q can be determined by accurately measuring the temperatures TR and TA and applying the pre-calibrated functional relationship between heat flux Q and the temperature difference (TA − TS) of the calorimeter rod. Based on the measured Q, the hemispherical total emissivity of the sample surface can then be calculated directly using the radiative heat transfer equation.
The dynamic calorimetric method determines the total hemispherical emissivity of a material by analyzing its temperature decay during radiative cooling under vacuum conditions [35,36]. In this approach, the sample is placed in a high-vacuum chamber to eliminate convective and conductive heat transfer. The sample is preheated to an initial temperature slightly above the target measurement range. After heating is stopped, the sample cools exclusively through thermal radiation to the constant-temperature walls of the cryogenic chamber. Throughout the free-cooling process, the sample temperature T is continuously recorded as a function of time t, allowing calculation of the instantaneous cooling rate at different temperatures. Under these conditions, the following thermal energy balance applies:
where m is the mass of the sample, c is its specific heat capacity, A is the effective radiating surface area, T is the instantaneous temperature of the vacuum chamber, is the hemispherical emissivity of the sample, is the Stefan–Boltzmann constant, and is the heat loss correction factor. By substituting the experimentally measured cooling rates at various temperatures into the rearranged form of Equation (4), the hemispherical total emissivity of the material can be calculated.
2.2. Radiometric Methods
The radiometric method is a technique for determining surface emissivity based on its fundamental definition. This approach involves directly measuring the radiant power emitted from a sample’s surface and comparing it to the radiant power emitted by an ideal blackbody at an identical temperature [37,38]. According to the principles of thermal radiation theory, the surface emissivity of an object is defined as the ratio of its emitted radiant power to that of a blackbody radiator, both measured at the same temperature . This relationship is expressed by the following equation:
where is the absolute temperature, is the spectral emissivity of the object at temperature, is the radiant power emitted from the object’s surface at temperature, and is the radiant power emitted from a blackbody at the same temperature. Experimentally, this is commonly achieved using a Fourier transform infrared (FTIR) spectrometer. The radiation intensity of both the sample and a reference blackbody are measured at the same temperature, enabling the direct calculation of the sample’s spectral emissivity.
2.3. Reflectance Methods
The reflectance method determines emissivity by irradiating the surface of an opaque sample with a standard radiation source of known properties [39,40]. A reflectometer measures the energy reflected from the sample’s surface to determine its spectral reflectance. For an opaque material, where transmittance is zero, the principle of energy conservation dictates that absorptance (α) and reflectance (ρ) are related by the equation . Applying Kirchhoff’s law of thermal radiation [41], which states that spectral absorptance equals spectral emissivity (α = ε) under thermal equilibrium, the emissivity can be calculated indirectly as .
3. Experimental Studies on Emissivity at Cryogenic Temperature
In experimental studies of material surface emissivity at cryogenic temperatures, two principal methods are employed to establish stable and controllable cryogenic environments: immersion cooling using cryogenic liquids and refrigeration-based cooling systems. Owing to significant challenges associated with applying reflectance methods under cryogenic conditions, research in this domain often favors direct measurement approaches, such as calorimetric and radiometric methods. The limitations of reflectance methods arise primarily from two factors. Firstly, interactions (including absorption, scattering, or phase transitions) between cryogenic fluids and incident light sources can introduce significant measurement errors. Secondly, cryogenic refrigeration often requires sealed containers at cryogenic temperatures, whose walls obstruct light transmission and the establishment of an optical path, making it difficult to implement reflection measurements.
Therefore, this section provides a systematic review of experimental methods and advances in the study of the surface emissivity of materials under cryogenic conditions, with a focus on direct measurement techniques, specifically calorimetric and radiometric methods. Table 1 compares and analyses different experimental techniques classified by calorimetric and radiometric methods across various dimensions, including measurement temperature ranges, cooling methods and experimental materials.
Table 1.
Characteristics of emissivity measurement devices based on the direct methods at cryogenic temperatures.
3.1. Experimental Studies Based on Calorimetry Methods
Early radiometric emission testing devices based on calorimetry predominantly used cryogenic liquids as cold sources, necessitating continuous replenishment during experiments to maintain stable low-temperature conditions. In addition, the apparatus under discussion generally comprised the entire test chamber, which was situated within a cryostat. Both the apparatus and the cryostat were maintained under vacuum in order to minimize measurement errors caused by thermal convection and gas conduction. In 1968, Cravalho et al. [42] developed a solid surface emissivity measurement apparatus for the liquid helium temperature range based on steady-state calorimetry principles. By using liquid helium as the coolant, this apparatus enabled precise measurement of radiative heat flux between parallel plates. The experimental demonstration was the first to show that radiative heat flux between two metal surfaces significantly increases under extremely small spacing conditions. This finding established a fundamental basis for experimental research on near-field radiative heat transfer at cryogenic temperatures.
In 1971, Anderson et al. [43] designed and constructed an experimental apparatus based on steady-state calorimetry to measure surface radiative properties at cryogenic temperatures. This system enabled the study of power absorption by sample surfaces at temperatures as low as 0.2 K when exposed to thermal radiation sources ranging from 0.9 K to 6 K. In contrast to the liquid helium cooling method used by Cravalho et al., this apparatus employed a dilution refrigerator, which provided lower sample temperature. The team systematically measured the emissivity of several materials, including copper, stainless steel, gold-plated stainless steel and others at temperatures below 6 K. Their work addressed a significant gap in empirical data on material radiative properties in the extreme cryogenic regime and provided critical experimental evidence to support the thermal design of cryostats and superconducting devices.
In 1977, Ramanathan et al. [36] introduced a dynamic calorimetry technique to determine the hemispherical total emissivity of copper, aluminum, and silver within the temperature range of 150–1000 K. For low-temperature experiments, as given in Figure 3, the team immersed a stainless-steel vacuum chamber in liquid nitrogen to establish a stable and uniform cryogenic environment. The study demonstrated that the “emission relaxation time” of the materials remained largely independent of temperature, indicating strong temperature insensitivity. This conclusion was supported by continuous recording of temperature decay curves over time using thermocouples attached to the sample surfaces.
Figure 3.
Schematic drawing of low temperature apparatus of Ramanathan et al. [36]. The dewar is used to contain liquid nitrogen. The samples are suspended within the vacuum chamber, where they exchange thermal radiation with the surrounding environment.
Subsequently, Giulietti et al. [45] developed a transient calorimetry apparatus to measure the hemispherical total emissivity and absorptivity of solid and coated materials at cryogenic temperatures. The team established a stable thermal environment using cryogenic baths at different temperatures. Emissivity was tested on both pure copper foil and copper foil coated with a blackbody layer at four characteristic temperatures: 293 K, 273 K, 195 K, and 77 K. A key innovation of their apparatus was a novel temperature-sensing strategy designed to minimize the thermal conduction errors inherent in conventional thermocouple measurements. This strategy involved indirectly inferring temperature changes by monitoring the thermal expansion behavior of the metal foil, thereby enhancing measurement precision and overall system accuracy.
In order to quantify the uncertainty in emissivity measurements, Jaworske et al. [46] adopted a similar research approach in 1993. They measured the emissivity of metals such as aluminum and copper in environments cooled by liquid nitrogen. To validate their experimental results, they developed a finite element analysis (FEA) model that simulated the low-temperature heat transfer processes. This model successfully corroborated the reliability of the empirical data and facilitated a systematic evaluation of measurement uncertainties.
Over the past two decades, the most representative development has been the material radiation property measurement apparatus developed at the Institute of Scientific Instruments of the Czech Academy of Sciences by Kralik et al. [33] in 2004, based on steady-state calorimetry. The apparatus employs liquid helium cooling and a concentric disk structure for measuring radiative heat flux. The measurement of the radiative heat flux density transferred from the emitter to the absorber is achieved through the calibrated calorimetric rod.
Using this apparatus, the team systematically investigated the total hemispherical absorptivity and emissivity of several cryogenic engineering materials within the 30–140 K temperature range, accounting for variations in surface treatment. The study confirmed the considerable influence of surface treatments on radiative properties, thereby providing reliable data for the thermal design of cryogenic systems. Furthermore, the researchers performed a detailed uncertainty analysis [6], applied systematic corrections to the measured values, and established an extensive database of cryogenic emissivity and absorptivity for multiple metallic materials and surface treatments [30]. This work significantly improved the reliability and practical utility of cryogenic radiation property data for engineering applications. In the early stages of material emissivity measurement, the majority of experiments relied on cryogenic liquid baths for cooling.
However, advances in cryogenic refrigeration have since enabled the use of mechanical coolers in calorimetry-based studies of radiative properties at cryogenic temperatures. In 2006, Duckworth et al. [47] employed a compact cryogenic refrigerator as the cold source, designing and constructing an experimental apparatus based on steady-state calorimetry to measure material emissivity at cryogenic temperatures. The apparatus simulated contaminants by means of injecting water vapor, thereby systematically investigating the surface emissivity of silver-plated copper samples across the 25–35 K temperature range and its variation under contaminated conditions. The experimental findings indicated that even minimal quantities of water vapor were capable of inducing a substantial enhancement in the surface emissivity of silver-plated copper, with the maximum increase observed reaching up to fourfold.
In 2012, Tuttle et al. [16] from NASA introduced a novel apparatus for measuring emissivity at cryogenic temperatures. The apparatus is shown schematically in Figure 4. The device was mounted on the cold head of a Gifford-McMahon (G-M) refrigerator and featured a double-coated aluminum hot sample plate suspended between two similarly coated aluminum cold plates, forming a pair of parallel radiative heat exchange surfaces. By measuring the heating power required to maintain a steady state under minimal temperature differences, the team derived the emissivity using a radiation heat transfer model for infinitely large parallel plates. This approach enabled successful measurement of the low-temperature emissivity of Black Infrared Black (BIRB) coatings, with results corroborated against existing datasets [56]. Furthermore, the team investigated BIRB coatings with varying areal densities and found that thinner, lighter coatings exhibited comparable or even superior emissivity relative to higher-density versions. This outcome offers valuable guidance for lightweight thermal design in spacecraft applications [8].
Figure 4.
A schematic view of the test apparatus and edge of the hot sample inside its cold enclosure [16]. The hot sample is suspended in the test chamber by the suspension ring and undergoes radiative heat exchange with the cold surfaces at the top and bottom.
Through the implementation of continual enhancements to the apparatus, the research team also conducted measurements of the emissivity of various painted aluminum honeycomb structures over the 30–300 K temperature range. The results largely corresponded to the theoretical predictions [9], thereby providing critical data support for the lightweight design of the James Webb Space Telescope (JWST) radiator. Furthermore, in order to precisely measure the low-temperature emissivity of the gold-plated small-diameter stainless steel tubes used in JWST, the team developed a steady-state calorimetry test apparatus cooled by a refrigeration unit [57]. The apparatus employs an isothermal aluminum honeycomb cavity with a high-emissivity coating on its inner walls, where the test sample is placed for emissivity measurement. Subsequently, the same apparatus was used to investigate the emissivity of unplated stainless steel tubes, accurately predicting the minimum time required for thermal cycling within the JWST system [58].
In 2014, Kim et al. [13] at Argonne National Laboratory developed a steady-state calorimetric system for measuring emissivity, cooled by liquid nitrogen. The sample was suspended within a test chamber using low-thermal-conductivity wires, with the entire assembly placed in a high-vacuum chamber. Temperature sensors and heating elements were also attached to the test chamber. The emissivity of the sample was calculated by heating it and measuring the parameters at radiative thermal equilibrium with the liquid nitrogen-cooled background. Using this apparatus, the team characterized the emissivity of several black coatings within the 80–120 K temperature range. The result provided critical input for optimizing thermal shielding structures in cryogenic accelerators and for reducing radiative heat leakage.
In 2018, Ando et al. [51] at the Japan Aerospace Exploration Agency (JAXA) developed a surface emissivity measurement apparatus for materials operating in the 20–80 K temperature range, employing a compact refrigeration unit as the cold source. The schematic of the apparatus is shown in Figure 5. Their experimental methodology was similar to that of Kim et al., with samples suspended within the test chamber using low-thermal-conductivity wires. Radiant heat flux was determined by precisely controlling the applied heating power and monitoring the resulting temperature response. Experimental results showed that the emissivity of flat surfaces decreased markedly with decreasing temperature, whereas the emissivity of honeycomb-structured surfaces exhibited minimal temperature dependence. Moreover, after applying a black coating, these surfaces maintained high emissivity even at cryogenic temperatures. These findings provide valuable design guidance for cryogenic radiative heat dissipation surfaces in ultra-sensitive astronomical observation missions.
Figure 5.
The schematic of the test apparatus: (a) Schematic of the layout (b) Detailed configuration [51]. Two layers of shielding covers are installed in the test chamber to prevent interference from external thermal radiation. In addition, to reduce heat leakage from the heater leads, temperature sensors, and related components, a guard heater plate (GHP) maintained at the same temperature as the sample was used during the test to minimize potential heat loss.
In 2019, Shen et al. [52] from the Institute of Physics and Chemistry, Chinese Academy of Sciences, developed a low-temperature emissivity measurement system based on a Gifford–McMahon (G–M) cryogenic cooler as shown in Figure 6. The apparatus incorporated a sample test rod isolated from the main vacuum chamber, allowing rapid sample replacement through a transition vacuum compartment without breaking the primary vacuum. Using steady-state calorimetry, this system enabled systematic emissivity measurements for a wide variety of materials over the temperature range of 15.4–300 K.
Figure 6.
The schematic of the measurement apparatus of Shen et al. [52]. This device measures radiative heat flux using a calorimetric rod. Its most distinctive feature is the ability to quickly replace the test rod for different thermal samples, thereby avoiding disruption of the vacuum environment in the test chamber and improving testing efficiency.
To further improve measurement efficiency and accommodate highly rough surfaces, Dewasi et al. [53] from the Institute for Plasma Research proposed a cost-effective steady-state calorimetry system in 2023. Liquid-nitrogen immersion was used to cool for the vacuum chamber, enabling emissivity measurements down to 82 K. It was shown that the use of high-emissivity radiators significantly shortened thermal equilibration times and improved overall testing efficiency.
In summary, steady-state calorimetry has become one of the most widely adopted methods for characterizing the surface emissivity of materials under cryogenic conditions. Nevertheless, researchers have demonstrated a range of design approaches in specific implementation methods, including calorimeter rod-type [33,47,52,59] and suspended-type [13,16,36,42,45,46,51,53] structures, as shown in Figure 7. In addition, measurement accuracy has been progressively improved through systematic error analysis and simulation-based verification of test systems. With respect to cooling techniques, the field has seen a gradual shift from liquid-cryogen baths [13,33,36,42,45,46,53] to refrigeration-based cooling systems [16,43,47,51,52]. This transition not only eliminates the operational challenges and resource consumption associated with continuous cryogen replenishment but also extends the lower limit of the measurable temperature range, enabling continuous emissivity testing across a broad temperature range [59]. In relation to test materials, researchers increasingly prioritize practical application needs. This includes investigations of common structural metals such as copper, aluminum, and stainless steel for cryogenic vessel design, as well as specialized functional surfaces such as black coatings [16] and honeycomb structures [51] for spacecraft thermal control. Moreover, studies on the effects of surface treatments and roughness [30,31] under realistic engineering conditions have significantly improved the accuracy of thermal modeling and simulation. Consequently, systematic emissivity measurements of diverse materials under cryogenic conditions not only expand the thermal property database for cryogenic materials but also provide critical experimental evidence and theoretical support for thermal management design in advanced systems such as spacecraft, space probes, and cryogenic instruments.
Figure 7.
The two different calorimetric models: (a) rod-type (b) suspended-type.
3.2. Experimental Studies Based on Radiometric Methods
In contrast to calorimetric methods, which infer emissivity indirectly through thermal equilibrium relationships, the radiometric method is based on direct radiation detection. In this approach, radiation signals from both the sample and a reference blackbody are collected under identical conditions using sensitive detectors, allowing emissivity to be calculated directly from the measured radiative energy. This method avoids the need for complex thermal process inversion and thus offers significantly faster testing speeds [53]. It is particularly well-suited for rapid spectral emissivity measurements and studies of transient radiative processes. However, under cryogenic conditions, the radiometric method presents substantial design challenges due to the inherently weak radiation signals and the strong influence of background noise, necessitating highly sensitive detectors and precise shielding strategies.
In 1971, Hawks et al. [44] at Purdue University developed a radiation measurement apparatus based on the radiometric method. The system employed a liquid-helium to establish a cryogenic environment and utilized a gallium-doped germanium pyrometer as the radiation detector. The pyrometer converted the radiation signals from both the sample and the reference blackbody into voltage outputs, from which the sample emissivity was calculated. To minimize background interference, all internal chamber walls were coated with a high-emissivity black layer. Using this system, the team measured the emissivity of several materials over the 5–100 K temperature range, including aluminum, copper, stainless steel, and black-coated copper. The experimental results exhibited excellent agreement with the reported data, thereby validating the accuracy and reliability of the apparatus.
In 2008, Herve et al. [37] from Paris Diderot University developed a low-temperature emissivity measurement system based on the radiometric method as presented in Figure 8. A refrigerator was employed as the cold source and incorporated a diamond window, enabling emissivity measurements over a temperature range of 20–200 K and a wavelength range of 6–800 µm. The design accommodated up to five samples simultaneously and utilized an electric mechanism to enable multi-angle measurements. Radiation signals were detected using a bolometer, and emissivity values were calculated with reference to a calibrated blackbody. This work provided valuable low-temperature emissivity data for various coatings, offering critical guidance for the thermal design of deep-space probes.
Figure 8.
Schematic diagram of the experimental setup and the sample holder [37]. The sample temperature can be reduced to a minimum of 20 K. The radiation signal passes through the mirror and then through the chopper before being absorbed by the bolometer. The red arrow indicates the direction of light propagation.
In 2012, Woods et al. [48] at the National Institute of Standards and Technology (NIST) developed a low-uncertainty, absolutely calibrated emissivity measurement system for the precise characterization of highly reflective materials. The apparatus employed a helium-cooled, high-absorption, low-noise absolute cryogenic radiometer as the detector. Based on the radiometric method, this system enabled precise emissivity measurements of polished 304 stainless steel across the 80–300 K temperature range [38]. By incorporating shutter-partitioning technology, it allowed independent emissivity measurements of multiple microregions on the same sample surface.
In 2013, Adibekyan et al. [49] developed an emissivity measurement apparatus operable above 173 K and covering the 4.5–20 µm wavelength range. Liquid-nitrogen was used to cool the system, and a Fourier-transform infrared spectrometer (FTIR) was employed to acquire radiation signals. In addition, the researchers validated the performance of Nextel Velvet Black 811-21 coating under vacuum cryogenic conditions [24], demonstrating excellent agreement with a reference blackbody and confirming its suitability for use in precision thermal control applications.
In 2018, Hao et al. [17] from the Chinese Academy of Metrology developed a vacuum radiation temperature standard apparatus for calibrating meteorological satellite infrared remote sensors. Liquid-nitrogen cooled channel and Fourier-transform infrared spectrometry (FTIR) were employed to measure emissivity above 190 K across the 1–1000 µm wavelength range. A liquid-nitrogen-cooled blackbody served as the FTIR radiation reference zero point. And the reference radiation was directed into the spectrometer using an off-axis parabolic mirror in combination with a flat elliptical mirror, ensuring high-precision optical alignment and signal collection.
In 2023, Zhao et al. [54] from the Institute of Physics and Chemistry, Chinese Academy of Sciences developed a low-temperature emissivity measurement system based on the energy method. The system employs a Gifford–McMahon (G-M) cryostat as the cooling source, allowing the sample to reach a minimum temperature of 9.2 K. The optical system, incorporating an MCT detector, is completely enclosed within a vacuum chamber, thereby eliminating the influence of windows and atmospheric radiation and significantly improving measurement accuracy. Furthermore, a stepper-motor-driven rotating sample stage enables automated switching between samples and efficient data acquisition.
Building on these advancements, Yuan et al. [55] from Henan Normal University proposed a novel cryogenic spectral emissivity measurement approach in 2024, incorporating radiation modulation and background optimization algorithms. Based on liquid-nitrogen cooling, they validated the reliability of the system by measuring the directional spectral emissivity of objects under varying temperature (213 to 423 K), spectrum (5 to 100 μm) and angle (0 to 75°).
The evolution of radiometric methods reveals several clear trends in experimental methodology. Initially, cooling methods evolved from reliance on external cryogenic liquids [17,44,49,55], such as liquid nitrogen and liquid helium, to integrated refrigeration system [37,54]. Secondly, there has been a transition in the arrangement of key optical paths from external detectors [17,37,49,55] to fully integrated designs [54]. Furthermore, the management of background noise has advanced from simple subtraction [44] to complex modeling and active adjustment [26,55], thereby enhancing the accuracy of testing systems. Indeed, accurately measuring the emissivity of materials at ultra-low temperatures and with high reflectivity remains a significant technical challenge. To overcome these difficulties, employing detector systems that integrate radiation modulation with autonomous background compensation is considered a critical strategy for achieving efficient and reliable measurements. In addition, the radiometric method has the capacity to obtain emissivity data across spectral bands, thus offering significant potential to guide thermal radiation design for materials at specific wavelengths in the future.
4. Conclusions
Review articles [60,61] on thermal radiation testing methods have previously been published. For example, A review by Zhang et al. [60] mainly provided a general overview of existing methods and instruments, briefly introducing the two main testing techniques along with sample data and instrument parameters, but it did not include in depth discussion. Moreover, Hashmi et al. [61] provided a more detailed review of thermal radiation testing methods at low temperatures. They primarily investigate the emissivity and absorptivity of metallic materials (particularly aluminum and stainless steel) at cryogenic temperatures. Also, their work provides a comprehensive summary of relevant experimental data and emphasizes the decisive influence of surface treatment on thermal radiation properties. Unlike the earlier reviews, this paper discusses methods for measuring the surface emissivity of various materials at cryogenic temperatures, thereby encompassing a broader temperature range and offer a wider selection of materials. The measurement techniques reviewed include calorimetry, radiometry, and reflectometry, while the tested materials comprise stainless steel, copper, aluminum, and novel blackbody coatings. Furthermore, this paper elaborates on the principles and technical characteristics of these testing methods and examines their applicability and future development trends with respect to cooling techniques, test materials, and system accuracy under cryogenic conditions.
In the future, advancements in this field will be driven by the mutual development of three key areas: testing technologies, material systems, and cryogenic applications. As demonstrated in Figure 9, these three fields are interconnected and mutually supportive. The ensuing sections will furnish a comprehensive perspective on prospective research trends, with a particular emphasis on innovation of measuring technologies, the development of novel material systems, and the expansion of cryogenic applications.
Figure 9.
Scheme of future development.
4.1. Measuring Technologies
In cryogenic environments, cryogenic liquid immersion and refrigeration technology are currently the primary methods for creating stable low-temperature conditions. In the future, with the continuous advancement of cryogenic refrigeration technology, particularly, breakthroughs in new refrigeration solutions that are highly efficient, vibration-free, and capable of covering lower temperature ranges. It is predicted that more stable, flexible, and broader-temperature-range extreme cryogenic environments will be provided for thermal radiation testing experiments.
In system accuracy, elevated background noise under low-temperature conditions has been demonstrated to pose significant challenges to emissivity measurements. The integration of theoretical modeling with experimental optimization has been demonstrated to be an effective approach to enhance measurement precision. The suppression of background radiation interference can be significantly enhanced through the utilization of models to guide the design and optimization of measurement systems. For instance, in Yuan et al.’s emissivity study [26], which was based on the measurement of direct radiation techniques, the accuracy of spectral emissivity measurements under low-temperature conditions was improved by means of a systematic evaluation and effective mitigation of the impact of background factors.
Regarding in situ testing techniques, most current studies remain at the experimental stage and primarily focus on macroscopic planar structures. In contrast, challenges remain in practical applications, such as heat rectifiers and transistors, as well as in emissivity testing at the micro and nano scale for surface heterogeneity.
4.2. Novel Material Systems
In the study of radiative properties of materials at cryogenic temperatures, the innovation and functionalization of material systems constitute a critical pathway for enhancing thermal control performance and expanding application potential. This primarily encompasses the following three aspects:
Initially, the surface modification of conventional materials [44,45,47]. Pure metal surfaces are susceptible to oxidation in cryogenic environments, resulting in substantial alterations to their radiative properties. Consequently, the development of protective coatings capable of withstanding extreme low temperatures to suppress surface oxidation and stabilize emissivity has become a crucial approach for enhancing the thermal performance reliability of metal-based materials.
Secondly, the design and development of novel functional materials [26,55]. As our understanding of the material spectral emission behavior at low temperatures continues to develop, it will become possible to engineer future materials with a view to meeting specific application requirements. These requirements may include radiation control within designated spectral bands or angular ranges. By optimizing material composition, microstructure, and surface morphology, it is possible to develop materials with spectrally selective and angle-dependent radiation characteristics. This greatly expands the thermal management capabilities of cryogenic devices.
Furthermore, the exploration of thermo-intelligent control materials [62,63,64]. The utilization of emerging systems, such as phase-change materials, two-dimensional materials (such as graphene, hexagonal boron nitride), and metamaterials, facilitates dynamic regulation of material emissivity under external stimulant (such as temperature changes, electric field control) at cryogenic temperatures. This finding offers a potential solution for the advancement of adaptive thermal management devices, thereby addressing the demand for efficient thermal control technologies in emerging fields such as deep space exploration and quantum computing.
4.3. Cryogenic Applications
In the context of deep-space and extraterrestrial planetary exploration missions [65], extreme low temperatures and intense radiation environments pose severe challenges to spacecraft thermal control systems. The optical components used in infrared instruments [66,67] require a cooling and preheating process. By using radiation heat exchange to shorten the time it takes to reach the equilibrium temperature, the availability of the equipment can be significantly improved. Therefore, it is essential that research is conducted into the radiation characteristics of materials under such conditions, with particular attention to the evolution of their spectral emissivity with temperature and environmental factors. This research is fundamental to ensuring the thermal safety and operational stability of probes during long-duration missions.
In the domain of precision electronic thermal management, technologies for regulating low-temperature radiation properties are of significant application value. For instance, the infrared stealth performance of military equipment in high-altitude cold regions is contingent on the precise design and control of surface material emissivity under cryogenic conditions. Conversely, precision observation platforms such as space telescopes require detectors to function in extremely low-temperature, highly stable thermal environments in order to suppress background thermal noise and achieve higher-precision deep-space observations.
Furthermore, advancements in materials radiation research have also driven the development of novel cryogenic instruments. For example, a novel variable emissivity technology has been developed under low-temperature vacuum conditions by harnessing the distinctive radiation properties of thermochromic materials [68]. This technology enables precise and adaptive thermal regulation of spacecraft, offering improved stability and efficiency in space environments.
Funding
This research was funded by the National Natural Science Foundation of China grant number [52407034].
Data Availability Statement
Data available on request from the authors.
Acknowledgments
The authors would like to thank Laifeng Li for his invaluable guidance on this thesis, and the Low Temperature Optics Research Group for their support.
Conflicts of Interest
The authors declare no conflict of interest.
References
- Lenert, A.; Bierman, D.M.; Nam, Y.; Chan, W.R.; Celanović, I.; Soljačić, M.; Wang, E.N. A Nanophotonic Solar Thermophotovoltaic Device. Nat. Nanotechnol. 2014, 9, 126–130. [Google Scholar] [CrossRef] [Scilit]
- Li, Y.-Z.; Wang, Y.-Y.; Lee, K.-M. Dynamic Modeling and Transient Performance Analysis of a LHP-MEMS Thermal Management System for Spacecraft Electronics. IEEE Trans. Compon. Packag. Technol. 2010, 33, 597–606. [Google Scholar] [CrossRef] [Scilit]
- Rawal, S.P.; Barnett, D.M.; Martin, D.E. Thermal Management for Multifunctional Structures. IEEE Trans. Adv. Packag. 1999, 22, 379–383. [Google Scholar] [CrossRef] [Scilit]
- Tsuda, S.; Shimizu, M.; Iguchi, F.; Yugami, H. Thermal Management Technique Using Control of Thermal Radiation Spectrum for Encapsulated Electronic Devices. IEEE Trans. Compon. Packag. Manuf. Technol. 2015, 5, 971–979. [Google Scholar] [CrossRef] [Scilit]
- Sai, H.; Yugami, H. Thermophotovoltaic Generation with Selective Radiators Based on Tungsten Surface Gratings. Appl. Phys. Lett. 2004, 85, 3399–3401. [Google Scholar] [CrossRef] [Scilit]
- Králík, T.; Musilová, V.; Hanzelka, P.; Frolec, J. Method for Measurement of Emissivity and Absorptivity of Highly Reflective Surfaces from 20 K to Room Temperatures. Metrologia 2016, 53, 743–753. [Google Scholar] [CrossRef] [Scilit]
- Barlet, A.; Genna, J.C.; Lethuillier, P. Insert for Regulating Temperatures between 2 and 1000 K in a Liquid Helium Dewar: Description and Cryogenic Analysis. Cryogenics 1991, 31, 801–805. [Google Scholar] [CrossRef] [Scilit]
- Tuttle, J.; Canavan, E.; DiPirro, M.; Li, X.; Franck, R.; Renbarger, M.; Copp, T.; Hahn, M. The Area-Density-Dependence of Ball IR Black’s Low-Temperature Emissivity. Cryogenics 2014, 64, 240–243. [Google Scholar] [CrossRef] [Scilit]
- Tuttle, J.; Canavan, E.; DiPirro, M.; Li, X.; Knollenberg, P. The Total Hemispheric Emissivity of Painted Aluminum Honeycomb at Cryogenic Temperatures. AIP Conf. Proc. Am. Inst. Phys. 2014, 1573, 590–596. [Google Scholar] [CrossRef] [Scilit]
- Rice, J.P.; Johnson, B.C. The NIST EOS Thermal-Infrared Transfer Radiometer. Metrologia 1998, 35, 505–509. [Google Scholar] [CrossRef] [Scilit]
- Blanc, J.; Ricci, D.; Kuhnhenn, J.; Weinand, U.; Schumann, O.J. Irradiation of Radiation-Tolerant Single-Mode Optical Fibers at Cryogenic Temperature. J. Light. Technol. 2017, 35, 1929–1935. [Google Scholar] [CrossRef] [Scilit]
- Hornibrook, J.M.; Colless, J.I.; Conway Lamb, I.D.; Pauka, S.J.; Lu, H.; Gossard, A.C.; Watson, J.D.; Gardner, G.C.; Fallahi, S.; Manfra, M.J.; et al. Cryogenic Control Architecture for Large-Scale Quantum Computing. Phys. Rev. Appl. 2015, 3, 024010. [Google Scholar] [CrossRef] [Scilit]
- Kim, S.H.; Conway, Z.A.; Ostroumov, P.N.; Shepard, K.W. Emissivity Measurement of Coated Copper and Aluminum Samples at 80 K. AIP Conf. Proc. Am. Inst. Phys. 2014, 1573, 500–506. [Google Scholar] [CrossRef] [Scilit]
- Youngquist, R.C.; Nurge, M.A.; Johnson, W.L.; Gibson, T.L.; Surma, J.M. Cryogenic Deep Space Thermal Control Coating. J. Spacecr. Rockets 2018, 55, 622–631. [Google Scholar] [CrossRef] [Scilit]
- Krenn, A.; Youngquist, R.; Gibson, T.; Snyder, S. Development of a Thermal Control Coating Optimized for Cryogenic Space Applications. IOP Conf. Ser. Mater. Sci. Eng. 2022, 1240, 012001. [Google Scholar] [CrossRef] [Scilit]
- Tuttle, J.; Canavan, E.R.; DiPirro, M.; Li, X.; Franck, R.; Green, D. A High-Resolution Measurement of the Low-Temperature Emissivity of Ball Infrared Black. AIP Conf. Proc. Am. Inst. Phys. 2012, 1434, 1505–1512. [Google Scholar] [CrossRef] [Scilit]
- Hao, X.P.; Song, J.; Xu, M.; Sun, J.P.; Gong, L.Y.; Yuan, Z.D.; Lu, X.F. Vacuum Radiance-Temperature Standard Facility for Infrared Remote Sensing at NIM. Int. J. Thermophys. 2018, 39, 78. [Google Scholar] [CrossRef] [Scilit]
- Honner, M.; Honnerová, P. Survey of Emissivity Measurement by Radiometric Methods. Appl. Opt. 2015, 54, 669. [Google Scholar] [CrossRef] [Scilit]
- Lawson, D. A Closer Look at Planck’s Blackbody Equation. Phys. Educ. 1997, 32, 321–326. [Google Scholar] [CrossRef] [Scilit]
- Narayanaswamy, A.; Shen, S.; Hu, L.; Chen, X.; Chen, G. Breakdown of the Planck Blackbody Radiation Law at Nanoscale Gaps. Appl. Phys. A 2009, 96, 357–362. [Google Scholar] [CrossRef] [Scilit]
- Ottens, R.S.; Quetschke, V.; Wise, S.; Alemi, A.A.; Lundock, R.; Mueller, G.; Reitze, D.H.; Tanner, D.B.; Whiting, B.F. Near-Field Radiative Heat Transfer between Macroscopic Planar Surfaces. Phys. Rev. Lett. 2011, 107, 014301. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Francoeur, M.; Pinar Mengüç, M. Role of Fluctuational Electrodynamics in Near-Field Radiative Heat Transfer. J. Quant. Spectrosc. Radiat. Transf. 2008, 109, 280–293. [Google Scholar] [CrossRef] [Scilit]
- Zhang, K.; Zhao, Y.; Yu, K.; Liu, Y. Development of Experimental Apparatus for Precise Emissivity Determination Based on the Improved Method Compensating Disturbances by Background Radiation. Infrared Phys. Technol. 2018, 92, 350–357. [Google Scholar] [CrossRef] [Scilit]
- Adibekyan, A.; Monte, C.; Kehrt, M.; Gutschwager, B.; Hollandt, J. Emissivity Measurement Under Vacuum from 4 Μm to 100 Μm and from -40 °C to 450 °C at PTB. Int. J. Thermophys. 2015, 36, 283–289. [Google Scholar] [CrossRef] [Scilit]
- Dozier, J.; Warren, S.G. Effect of Viewing Angle on the Infrared Brightness Temperature of Snow. Water Resour. Res. 1982, 18, 1424–1434. [Google Scholar] [CrossRef] [Scilit]
- Yuan, Z.; Li, L.; Cui, M.; Wang, Q.; Yu, K.; Liu, Y. Optimization of Low-Temperature Spectral Emissivity Measurement Scheme Based on Background Factor Evaluation. Opt. Express 2025, 33, 4647. [Google Scholar] [CrossRef] [Scilit]
- Wen, C.-D.; Mudawar, I. Emissivity Characteristics of Roughened Aluminum Alloy Surfaces and Assessment of Multispectral Radiation Thermometry (MRT) Emissivity Models. Int. J. Heat Mass Transf. 2004, 47, 3591–3605. [Google Scholar] [CrossRef] [Scilit]
- Wen, C.-D.; Mudawar, I. Modeling the Effects of Surface Roughness on the Emissivity of Aluminum Alloys. Int. J. Heat Mass Transf. 2006, 49, 4279–4289. [Google Scholar] [CrossRef] [Scilit]
- Barbarino, S.; Grasso, F.; Guerriera, G.; Musumeci, F.; Scordino, A.; Triglia, A. Surface Roughness Effect on Optical Absorptivity of Metals. Appl. Phys. Solids Surf. 1982, 29, 77–80. [Google Scholar] [CrossRef] [Scilit]
- Frolec, J.; Králík, T.; Musilová, V.; Hanzelka, P.; Srnka, A.; Jelínek, J. A Database of Metallic Materials Emissivities and Absorptivities for Cryogenics. Cryogenics 2019, 97, 85–99. [Google Scholar] [CrossRef] [Scilit]
- Musilova, V.; Kralik, T.; Hanzelka, P.; Srnka, A. Effect of Different Treatments of Copper Surface on Its Total Hemispherical Absorptivity Bellow 77K. Cryogenics 2007, 47, 257–261. [Google Scholar] [CrossRef] [Scilit]
- Zhu, C.; Hobbs, M.J.; Willmott, J.R. An Accurate Instrument for Emissivity Measurements by Direct and Indirect Methods. Meas. Sci. Technol. 2020, 31, 044007. [Google Scholar] [CrossRef] [Scilit]
- Musilova, V.; Hanzelka, P.; Kralik, T.; Srnka, A. Low Temperature Radiative Properties of Materials Used in Cryogenics. Cryogenics 2005, 45, 529–536. [Google Scholar] [CrossRef] [Scilit]
- Blevin, W.R.; Brown, W.J. A Precise Measurement of the Stefan-Boltzmann Constant. Metrologia 1971, 7, 15–29. [Google Scholar] [CrossRef] [Scilit]
- Roger, C.R.; Yen, S.H.; Ramanathan, K.G. Temperature Variation of Total Hemispherical Emissivity of Stainless Steel AISI 304. J. Opt. Soc. Am. 1979, 69, 1384. [Google Scholar] [CrossRef] [Scilit]
- Ramanathan, K.G.; Yen, S.H.; Estalote, E.A. Total Hemispherical Emissivities of Copper, Aluminum, and Silver. Appl. Opt. 1977, 16, 2810. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Herve, P.; Rambure, N.; Sadou, A.; Ramel, D.; Francou, L.; Delouard, P.; Gavila, E. Direct Measurement of Total Emissivities at Cryogenic Temperatures: Application to Satellite Coatings. Cryogenics 2008, 48, 463–468. [Google Scholar] [CrossRef] [Scilit]
- Woods, S.I.; Jung, T.M.; Sears, D.R.; Yu, J. Emissivity of Silver and Stainless Steel from 80K to 300K: Application to ITER Thermal Shields. Cryogenics 2014, 60, 44–48. [Google Scholar] [CrossRef] [Scilit]
- Ageladarakis, P.A.; Obert, W. On the Emissivity of Silver Coated Panels, Effect of Long Term Stability and Effect of Coating Thickness. In Proceedings of the Cryogenic Engineering Conference & International Cryogenic Materials Conference (CEC/ICMC 1999), Montreal, QC, Canada, 12–16 July 1999. [Google Scholar]
- Tsujimoto, S.; Kanda, M.; Kunitomo, T. Thermal Radiative Properties of Some Cryogenic Materials. Cryogenics 1982, 22, 591–597. [Google Scholar] [CrossRef] [Scilit]
- Karwa, R. Heat and Mass Transfer; Springer: Singapore, 2020. [Google Scholar] [CrossRef] [Scilit]
- Cravalho, E.; Domoto, G.; Tien, C. Measurements of Thermal Radiation of Solids at Liquid-Helium Temperatures. In 3rd Thermophysics Conference; American Institute of Aeronautics and Astronautics: Los Angeles, CA, USA, 1968. [Google Scholar] [CrossRef] [Scilit]
- Anderson, A.C.; Folinsbee, J.T.; Johnson, W.L. Measurement and Control of Thermal Radiation below 6K. J. Low Temp. Phys. 1971, 5, 591–605. [Google Scholar] [CrossRef] [Scilit]
- Hawks, K.H.; Cottingham, W.B. Total Normal Emittances of Some Real Surfaces at Cryogenic Temperatures. In Advances in Cryogenic Engineering; Timmerhaus, K.D., Ed.; Springer: Boston, MA, USA, 1971; pp. 467–474. [Google Scholar] [CrossRef] [Scilit]
- Giulietti, D.; Gozzini, A.; Lucchesi, M.; Stampacchia, R. A Calorimetric Technique for Measuring Total Emissivity of Solid Materials and Coatings at Low Temperatures. J. Phys. Appl. Phys. 1979, 12, 2027–2036. [Google Scholar] [CrossRef] [Scilit]
- Jaworske, D.A. Thermal Modeling of a Calorimetric Technique for Measuring the Emittance of Surfaces and Coatings. Thin Solid Films 1993, 236, 146–152. [Google Scholar] [CrossRef] [Scilit]
- Duckworth, R.C. Measurement of the Emissivity of Clean and Contaminated Silver Plated Copper Surfaces at Cryogenic Temperatures. AIP Conf. Proc. Am. Inst. Phys. 2006, 824, 61–68. [Google Scholar] [CrossRef] [Scilit]
- Woods, S.I.; Jung, T.M.; Ly, G.T.; Yu, J. Broadband Emissivity Calibration of Highly Reflective Samples at Cryogenic Temperatures. Metrologia 2012, 49, 737–744. [Google Scholar] [CrossRef] [Scilit]
- Adibekyan, A.R.; Monte, C.; Kehrt, M.; Morozova, S.P.; Gutschwager, B.; Hollandt, J. The Development of Emissivity Measurements under Vacuum at the PTB. Meas. Tech. 2013, 55, 1163–1171. [Google Scholar] [CrossRef] [Scilit]
- Lohrengel, J.; Todtenhaupt, R. Thermal conductivity, total emissivity and spectral emissivities of the Nextel Velvet 811-21 coating (RAL 900 15 deep black matted). PTB 1996, 106, 259–265. [Google Scholar]
- Ando, M.; Tanaka, K.; Shinozaki, K.; Nishikawa, I.; Sugita, H. Emissivity of Black Plated Open Honeycomb and Black Coatings at Cryogenic Temperatures. IOP Conf. Ser. Mater. Sci. Eng. 2019, 502, 012071. [Google Scholar] [CrossRef] [Scilit]
- Shen, F.; Xu, D.; Li, X.; Liu, H.; Li, L. Cryogen-Free Apparatus for Rapid Thermal Emissivity Measurements at Low Temperature. Mater. Sci. Eng. 2018, 502, 012190. [Google Scholar] [CrossRef] [Scilit]
- Dewasi, A.; Gangradey, R.; Mukherjee, S.S.; Gupta, V.; Dutta, R.; Desai, A.B.; Mishra, J.S.; Panchal, P.; Nayak, P.A.; Agravat, H.S. The Development of a Novel Apparatus to Measure the Emissivity of High-Roughness Materials at 82 K. Meas. Sci. Technol. 2023, 34, 125908. [Google Scholar] [CrossRef] [Scilit]
- Zhao, Y.; Li, X.; Zhang, H.; Shen, F.; Huang, C.; Liu, H.; Qi, H.; Huang, Z.; Geng, Z.; Xin, J.; et al. Preliminary Development of Emissivity Measurement System at Low Temperature Based on Radiometric Method. Cryogenics 2023, 132, 103671. [Google Scholar] [CrossRef] [Scilit]
- Yuan, Z.; Li, L.; Yu, K.; Zhang, K.; Liu, Y. Directional Spectral Emissivity Measurement Approach in a Broad-Spectrum at Low Temperatures: Device and Methodology Study. Measurement 2024, 225, 113999. [Google Scholar] [CrossRef] [Scilit]
- Franck, R.; Renbarger, M. Cryogenic Emissivity Properties of Ball Infrared Black. AIP Conf. Proc. Am. Inst. Phys. 2012, 1434, 1497–1504. [Google Scholar] [CrossRef] [Scilit]
- Tuttle, J.; Jahromi, A.; Canavan, E.; DiPirro, M. Cryogenic Thermal Absorptance Measurements on Small-Diameter Stainless Steel Tubing. Cryogenics 2016, 74, 166–171. [Google Scholar] [CrossRef] [Scilit]
- Jahromi, A.E.; Tuttle, J.G.; Canavan, E.R. Cryogenic Thermal Emittance Measurements on Small-Diameter Stainless Steel Tubing. IOP Conf. Ser. Mater. Sci. Eng. 2017, 278, 012002. [Google Scholar] [CrossRef] [Scilit]
- Zhang, S.Y.; Shen, F.Z.; Liu, H.M.; Huang, C.J.; Li, L.F. The Experimental Measurement of the Thermal Emissivity of a Black Coating from 50 K to 300 K. IOP Conf. Ser. Mater. Sci. Eng. 2022, 1241, 012053. [Google Scholar] [CrossRef] [Scilit]
- Zhang, S.Y.; Li, Y.; Li, L.F. A Review of Devices and Methods for Measuring Thermal Emissivity at Cryogenic Temperatures. IOP Conf. Ser. Mater. Sci. Eng. 2022, 1241, 012050. [Google Scholar] [CrossRef] [Scilit]
- Hashmi, A.R.; Wang, B.; Saadat, F.; Gan, Z. Progress in Measuring Techniques and Thermal Radiative Properties of Metals at Cryogenic Temperatures: A Review. Cryogenics 2024, 143, 103950. [Google Scholar] [CrossRef] [Scilit]
- Castillo-López, S.G.; Pirruccio, G.; Villarreal, C.; Esquivel-Sirvent, R. Near-Field Radiative Heat Transfer between High-Temperature Superconductors. Sci. Rep. 2020, 10, 16066. [Google Scholar] [CrossRef] [Scilit]
- Wei, H.; Gu, J.; Ren, F.; Zhang, L.; Xu, G.; Wang, B.; Song, S.; Zhao, J.; Dou, S.; Li, Y. Smart Materials for Dynamic Thermal Radiation Regulation. Small 2021, 17, 2100446. [Google Scholar] [CrossRef] [Scilit]
- Yu, R.; Fan, S. Time-Modulated near-Field Radiative Heat Transfer. Proc. Natl. Acad. Sci. USA 2024, 121, e2401514121. [Google Scholar] [CrossRef] [Scilit]
- Wrbanek, J.D.; Wrbanek, S.Y. Space Radiation and Impact on Instrumentation Technologies; NASA/TP–2020-220002; NASA: Glenn Research Center: Cleveland, OH, USA, 2020; 34p. [Google Scholar]
- Murakami, H.; Freund, M.M.; Ganga, K.; Guo, H.; Hirao, T.; Hiromoto, N.; Kawada, M.; Lange, A.E.; Makiuti, S.; Matsuhara, H.; et al. The IRTS (Infrared Telescope in Space) Mission. Publ. Astron. Soc. Jpn. 1996, 48, L41–L46. [Google Scholar] [CrossRef] [Scilit]
- Siegel, P.H. THz Instruments for Space. IEEE Trans. Antennas Propag. 2007, 55, 2957–2965. [Google Scholar] [CrossRef] [Scilit]
- Tachikawa, S.; Nagano, H.; Ohnishi, A.; Nagasaka, Y. Advanced Passive Thermal Control Materials and Devices for Spacecraft: A Review. Int. J. Thermophys. 2022, 43, 91. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.