Skip to Content
LabMedLabMed
  • Review
  • Open Access

27 November 2026

39 Pages

Platelet Immunology in the Clinical Laboratory: Diagnostic Algorithms, Serology, Genotyping, and Transfusion Support

,
,
,
and
1
Blood and Transplantation Center of Lisbon, Instituto Português do Sangue e da Transplantação, Alameda das Linhas de Torres, No. 117, 1769-001 Lisbon, Portugal
2
NOVA Medical School, Faculdade de Ciências Médicas, Universidade NOVA de Lisboa, 1169-056 Lisbon, Portugal
3
iNOVA4Health—Advancing Precision Medicine, Núcleo de Investigação em Doenças Renais, NOVA Medical School, Faculdade de Ciências Médicas, Universidade NOVA de Lisboa, 1169-056 Lisbon, Portugal
4
LBS—Lisbon Business & Government School, Rua de São Bernardo, 34-A, 1200-427 Lisbon, Portugal
This article belongs to the Special Issue Laboratory Medicine in Hematology

Abstract

Immune-mediated platelet disorders comprise clinically distinct conditions in which laboratory investigation can be essential for diagnosis, transfusion support, and subsequent patient management. Their consequences range from fetal or neonatal hemorrhage and severe thrombocytopenia to ineffective platelet transfusion and thrombosis. The diagnostic challenge is not simply to detect an antibody. A positive result must be interpreted in relation to the clinical phenotype, timing, antibody specificity, and, where relevant, the antigenic profile of the patient, donor, mother, father, fetus, or neonate. This review examines the laboratory investigation of fetal and neonatal alloimmune thrombocytopenia, platelet transfusion refractoriness, post-transfusion purpura, immune thrombocytopenia, drug-induced immune thrombocytopenia, and heparin-induced thrombocytopenia. Particular attention is given to platelet antibody assays, glycoprotein-specific methods, HLA antibody analysis, HPA and HLA genotyping, PF4-dependent immunoassays, and functional platelet activation testing. These methods provide different layers of diagnostic information and should not be considered interchangeable. We present a phenotype-driven framework that integrates serological, molecular, functional, and clinical evidence while addressing diagnostic discordance, assay-dependent limitations, and situations requiring urgent management. The review critically examines emerging technologies, unresolved controversies, and the distinction between analytical performance and demonstrated clinical utility. Practical algorithms and laboratory reporting recommendations are proposed to support defensible immunological interpretation and appropriate transfusion decisions.

1. Introduction

Immune-mediated platelet disorders comprise a heterogeneous group of conditions in which laboratory investigation may be central to diagnosis, transfusion support, and clinical management. Although several are individually uncommon, their consequences can be severe. Fetal or neonatal hemorrhage, profound thrombocytopenia, ineffective platelet transfusion, and thrombosis are among the most important clinical manifestations [1,2,3,4,5,6]. Major entities include fetal and neonatal alloimmune thrombocytopenia (FNAIT), platelet transfusion refractoriness, post-transfusion purpura (PTP), immune thrombocytopenia (ITP), drug-induced immune thrombocytopenia (DITP), and heparin-induced thrombocytopenia (HIT).
The principal laboratory challenge is not simply antibody detection. Similar thrombocytopenic phenotypes may arise through immune and non-immune mechanisms, while a detectable antibody does not necessarily establish pathogenic relevance. Its significance depends on the clinical and temporal setting, antibody specificity, and, in alloimmune conditions, whether the corresponding antigen is present in the biologically relevant individual. Depending on the disorder, that individual may be the patient, platelet donor, father, fetus, or neonate. The major conditions considered in this review, their immunologic targets, and the principal contribution of the clinical laboratory are summarized in Table 1.
Table 1. Major immune-mediated platelet disorders and the contribution of the clinical laboratory.
These disorders involve different immune mechanisms and therefore require different analytical strategies. FNAIT results from maternal alloantibodies directed against paternally inherited fetal platelet antigens, whereas immune platelet transfusion refractoriness is most frequently associated with HLA class I antibodies and less commonly with HPA antibodies [1,2]. PTP is also predominantly associated with HPA alloimmunization [3]. In contrast, ITP involves platelet-reactive autoantibodies, DITP may involve antibodies whose binding depends on the presence of a drug, and HIT is mediated by antibodies recognizing complexes containing platelet factor 4 and polyanions [4,5,6]. These mechanisms cannot be investigated through a single universal platelet antibody assay.
The clinical context remains essential even after specialized testing has begun. In platelet transfusion refractoriness, anti-HLA antibodies should be interpreted only after an inadequate post-transfusion response has been objectively demonstrated and relevant non-immune causes have been considered [2]. In FNAIT, a maternal HPA antibody becomes considerably more informative when its specificity corresponds to an antigen absent from the mother and present in the father, fetus, or neonate [1]. The situation is different in ITP. Glycoprotein-specific autoantibody assays have high specificity but limited sensitivity; a meta-analysis reported pooled sensitivity of 53% and specificity of 93% for direct testing, so a negative result cannot exclude the diagnosis [4]. HIT follows yet another model, integrating clinical pretest probability with PF4-dependent immunoassays and, when necessary, functional platelet activation testing [6].
The analytical repertoire available to specialized laboratories has expanded considerably. It now includes intact-cell platelet assays, glycoprotein-specific methods, multiplex bead-based platforms, HLA antibody screening and single-antigen testing, flow cytometry, PF4-dependent immunoassays, functional platelet activation assays, and molecular HPA and HLA typing. These methods answer different questions. They also have different limitations, and comparative studies show that individual platelet antibody platforms may identify partly overlapping rather than identical antibody repertoires [7].
For this reason, laboratory investigation is best approached as a sequence rather than as a collection of independent tests. The process starts with confirmation of the clinical or hematologic phenotype and assessment of relevant non-immune explanations. Targeted immunologic testing follows. Molecular antigen characterization or functional testing is then added when it provides information that cannot be obtained from serology alone. Final interpretation should bring together antibody specificity, antigenic context, functional evidence where available, and clinical concordance.
The laboratory investigation of immune-mediated platelet disorders has undergone substantial technological development. Sensitive solid-phase assays, molecular genotyping, multiplex antibody detection, and functional platelet activation methods now provide information that was previously difficult to obtain. Nevertheless, greater analytical resolution has not eliminated diagnostic uncertainty. Antibody detection does not invariably establish pathogenicity, antigen incompatibility does not necessarily predict clinical disease, and laboratory compatibility does not guarantee an adequate response to platelet transfusion [1,2,7,8,9,10,11,12].
These limitations become particularly important when analytical platforms produce discordant findings, when several mechanisms contribute to thrombocytopenia, or when urgent clinical decisions must precede completion of specialized laboratory investigations. The challenge extends beyond identifying an antibody or defining an antigenic incompatibility. It requires determining whether the available evidence supports a biologically plausible mechanism that is sufficiently consistent with the clinical phenotype to influence patient management [2,6,10,11,13].
This review addresses platelet immunology from that perspective. Rather than examining individual disorders or analytical techniques in isolation, it critically integrates clinical assessment, antibody characterization, molecular antigen definition, and functional evidence across distinct immune-mediated platelet conditions. Particular attention is given to unresolved diagnostic controversies, the limitations of established testing strategies, and emerging technologies whose analytical capabilities have not yet been consistently translated into demonstrated clinical benefit [1,8,14,15,16,17,18].
This general framework is illustrated in Figure 1.
Figure 1. Integrated laboratory approach to immune-mediated platelet disorders. The proposed pathway begins with recognition of the clinical or hematologic phenotype and assessment of relevant alternative explanations. Subsequent investigation incorporates targeted antibody detection, specificity assignment, molecular antigen characterization, and functional testing when indicated. These investigations may proceed in parallel when clinically justified. Urgent clinical management should not be delayed while laboratory confirmation is pending. Final interpretation considers analytical findings, antigenic or mechanistic concordance, clinical context, and relevant assay limitations. This figure represents an author-integrated synthesis based on established laboratory and clinical principles [1,2,6,17,19,20] and has not undergone independent prospective validation. CCI, corrected count increment; HLA, human leukocyte antigen; HPA, human platelet antigen; PF4, platelet factor 4.
The contribution of this review lies in its cross-disorder, laboratory-centered interpretation of evidence, with emphasis on the distinction between analytical detection, mechanistic plausibility, clinical validity, and clinical utility. The proposed diagnostic pathways seek to clarify when additional investigations are justified, how discordant results should be approached, and how laboratory findings can support diagnostic and transfusion decisions without delaying necessary clinical intervention.

Review Design, Evidence Selection, and Development of Diagnostic Algorithms

This narrative review examines the laboratory investigation of immune-mediated platelet disorders, with particular emphasis on diagnostic interpretation, analytical limitations, and the contribution of immunohematological findings to clinical and transfusion decisions. The conditions considered were selected to represent major clinical settings in which platelet immunology investigations contribute to diagnosis or management: fetal and neonatal alloimmune thrombocytopenia, platelet transfusion refractoriness, post-transfusion purpura, immune thrombocytopenia, drug-induced immune thrombocytopenia, and heparin-induced thrombocytopenia.
The evidence discussed includes international clinical practice guidelines, recommendations from scientific and standardization committees, systematic reviews, comparative analytical investigations, and original clinical studies. Particular attention is given to research examining diagnostic performance, antigen–antibody relationships, assay limitations, molecular characterization, functional testing, and the consequences of laboratory findings for clinical management.
The literature was identified and selected through a topic-oriented, iterative approach consistent with the narrative design of this review. The evidence base was organized around six major clinical conditions: fetal and neonatal alloimmune thrombocytopenia, platelet transfusion refractoriness, post-transfusion purpura, immune thrombocytopenia, drug-induced immune thrombocytopenia, and heparin-induced thrombocytopenia. Particular emphasis was placed on laboratory diagnostic methods, antibody specificity, molecular antigen characterization, functional testing, and transfusion support.
The literature considered included peer-reviewed original studies, systematic reviews, meta-analyses, international clinical practice guidelines, consensus statements, and recommendations from scientific and standardization committees. A supplementary targeted verification of PubMed-indexed literature was undertaken on 19 November 2026, using combinations of terms related to “platelet transfusion refractoriness”, “HLA antibodies”, “platelet crossmatch”, “fetal and neonatal alloimmune thrombocytopenia”, “HPA antibodies”, “heparin-induced thrombocytopenia”, “functional assays”, “4Ts score”, “immune thrombocytopenia”, and “platelet autoantibody testing”. Relevant reference lists were also considered during the development of the review.
Evidence selection prioritized methodological quality, clinical relevance, diagnostic performance, and applicability to specialized immunohematology laboratories. Foundational publications were retained when necessary to describe established analytical principles, while recent studies were emphasized when addressing technological developments, diagnostic controversies, and evolving clinical recommendations. Particular attention was given to distinguishing analytical validation from clinical validity and demonstrated clinical utility.
The diagnostic algorithms were developed through critical integration of the selected evidence and published recommendations. They represent an interpretive synthesis rather than independently validated diagnostic models. As this was a narrative review, no formal systematic screening, risk-of-bias assessment, or quantitative evidence synthesis was performed.
When interpreting the available literature, a distinction is made between analytical validation, clinical diagnostic performance, and demonstrated clinical utility. Studies establishing methodological concordance or analytical sensitivity are not considered equivalent to investigations demonstrating improved diagnostic classification or patient outcomes. This distinction is particularly relevant to emerging molecular and computational technologies, for which technical feasibility may precede evidence supporting routine clinical implementation.

2. Antigenic and Molecular Basis of Platelet Immune Disorders

2.1. Human Platelet Antigens

Human platelet antigens (HPAs) are polymorphic epitopes located on membrane glycoproteins involved in platelet adhesion, aggregation, and signaling. Most clinically relevant HPA polymorphisms result from single-nucleotide variants that produce a single amino acid substitution and alter an extracellular epitope of the corresponding glycoprotein [21,22,23]. Major antigenic carriers include integrin αIIbβ3 (GPIIb/IIIa), the GPIb-IX-V complex, integrin α2β1 (GPIa/IIa), and CD109. Several of the best-characterized HPA systems are biallelic, whereas additional platelet alloantigens occur at considerably lower population frequencies [21,22].
The clinical relevance of these polymorphisms becomes apparent when an individual lacking a particular HPA is exposed to the corresponding antigen during pregnancy or transfusion and subsequently develops an alloantibody. HPA alloimmunization is central to fetal and neonatal alloimmune thrombocytopenia (FNAIT) and post-transfusion purpura (PTP). HPA antibodies may also contribute to selected cases of platelet transfusion refractoriness [21,22]. HPA allele frequencies vary between populations. In individuals of European ancestry, anti-HPA-1a alloimmunization accounts for most clinically recognized cases of FNAIT, while the relative importance of other HPA specificities differs across populations [1,21].
Molecular characterization has become an established component of the investigation of alloimmune platelet disorders. Targeted PCR-based methods remain widely used, while multiplex and sequencing-based approaches allow several HPA polymorphisms to be characterized simultaneously [23]. Genotyping is particularly valuable when suitable serologic typing reagents are unavailable, platelet numbers are insufficient for reliable phenotyping, or maternal, paternal, fetal, neonatal, patient, or donor antigen status needs to be established. It is important, however, to distinguish what the result demonstrates. Genotyping defines the genetic basis of antigen status; it does not demonstrate that an antibody has formed or that an identified incompatibility is clinically relevant [22,23].
This distinction is particularly important in FNAIT. Detection of a maternal platelet-reactive antibody is most informative when its specificity corresponds to an antigen absent from the mother and inherited by the fetus from the father [1]. Maternal and paternal HPA genotyping, followed by fetal or neonatal typing when required, provides the antigenic context needed to interpret the serologic result.
Noninvasive fetal HPA genotyping has expanded this molecular approach. Cell-free fetal DNA obtained from maternal plasma can be analyzed using targeted PCR, droplet digital PCR, or next-generation sequencing, avoiding invasive fetal sampling. Recent methods offer broader multiplex capacity and can incorporate internal assessment of fetal DNA representation, which becomes particularly important when the fetal fraction is low [24,25].

2.2. HLA Class I Antigens and Platelet Alloimmunization

Platelets express HLA class I molecules and can therefore be recognized by circulating anti-HLA class I antibodies [2,8,19,20,26]. Alloimmunization may follow pregnancy, transfusion, or transplantation and remains the predominant immune mechanism underlying platelet transfusion refractoriness. HPA antibodies are considerably less frequent in this setting, although the two antibody populations may coexist [2,8,26].
Platelet HLA expression is not uniform. Flow cytometric analysis of healthy donors has demonstrated substantial interindividual variability in HLA class I surface expression, with differences associated with specific HLA allele groups [19]. This variability is potentially relevant to transfusion outcome. Antibody detection alone does not completely describe the interaction between a recipient’s antibody repertoire and the transfused platelet population, and platelet clearance may be influenced by antibody specificity, antibody characteristics, and the amount of target antigen expressed on the platelet surface [19,26].
The introduction of highly sensitive solid-phase assays has added another layer of complexity. Single-antigen bead platforms can define broad and detailed HLA antibody repertoires, but an analytically detectable antibody is not necessarily associated with clinically significant platelet destruction. Nevertheless, detection of HLA alloantibodies does not, by itself, establish clinically significant immune refractoriness [2,8,20,26]. For this reason, antibody specificity should be interpreted together with the transfusion history, objectively documented post-transfusion platelet response, recipient HLA type, and the HLA profile of potential platelet donors.
The practical consequence is that compatibility assessment now extends beyond a simple positive or negative HLA antibody result. Depending on the degree and pattern of sensitization, donor availability, and local infrastructure, transfusion support may involve HLA-matched platelets, antibody-specific antigen avoidance, virtual compatibility assessment, or physical platelet crossmatching [2,8]. These strategies are considered in greater detail in the sections addressing platelet transfusion refractoriness and laboratory-guided transfusion support.

2.3. Non-Alloimmune Targets in Platelet Immune Disorders

Not all clinically important platelet immune disorders are driven by polymorphic alloantigens. In ITP, DITP, and HIT, antibody recognition follows different biological mechanisms, and the corresponding laboratory findings have different diagnostic implications.
In ITP, platelet-reactive autoantibodies commonly recognize surface glycoprotein complexes, particularly αIIbβ3 and GPIb-IX. These antibodies may promote platelet clearance and, in some patients, interfere with platelet function or production. Their detection can support an immune mechanism, but analytical sensitivity remains incomplete. The absence of a demonstrable glycoprotein-specific autoantibody therefore cannot exclude ITP [4].
DITP presents a different form of antibody–antigen interaction. Antibody binding may occur only in the presence of the implicated drug or one of its metabolites, and several mechanistic patterns have been described. The relevant antigenic structure may depend on a drug-induced interaction with a platelet glycoprotein rather than on a constitutively expressed alloantigen [5]. Consequently, drug-dependent antibody testing requires analytical conditions that reproduce the relevant drug-antibody-platelet interaction as closely as possible.
HIT is mechanistically distinct from both ITP and conventional drug-dependent thrombocytopenia. The pathogenic immune response is directed against complexes formed between platelet factor 4 (PF4) and negatively charged polyanions, most notably heparin [6]. Antibody binding alone is not sufficient to establish pathogenicity. Clinically relevant HIT antibodies are characterized by their ability to activate platelets, which explains why functional platelet activation assays occupy a different diagnostic position from conventional platelet antibody tests [6].
These disorders illustrate why the term “platelet antibody” cannot be interpreted as a single biological category. The antigenic target, the conditions required for antibody binding, and the relationship between antibody detection and pathogenic activity vary substantially across platelet immune disorders.

2.4. From Antigen Definition to Immunologic Concordance

Despite these biological differences, a common interpretive principle applies across platelet immunology: an analytical result acquires clinical meaning only when it can be placed within the relevant biological and clinical context.
In alloimmune disorders, this often requires demonstration of a plausible antibody–antigen relationship. In FNAIT, the relevant interaction involves the maternal antibody repertoire and a paternally inherited fetal platelet antigen. In immune platelet transfusion refractoriness, it involves recipient alloantibodies and antigens expressed by transfused platelets [1,2,23]. Antigen typing therefore provides context for antibody identification rather than an independent diagnosis. Conversely, demonstration of an antigenic incompatibility establishes the possibility of an immune response but does not show that alloimmunization has actually occurred.
The nature of concordance differs in non-alloimmune disorders. In DITP, the critical relationship is between antibody reactivity and exposure to the implicated drug [5]. In HIT, diagnostic confidence depends on the relationship between clinical probability, PF4-dependent antibody detection, and, when required, demonstration of platelet activation [6]. ITP is different again because no single antibody–antigen combination is required to establish the clinical diagnosis [4].
These distinctions define the type of biological concordance required in each disorder. Antigen incompatibility supports alloimmune mechanisms, drug dependence supports DITP, and platelet activation provides functional evidence in HIT; in ITP, glycoprotein-specific autoreactivity remains supportive rather than diagnostic.
The principal antigenic targets, molecular carriers, clinical associations, and laboratory approaches relevant to platelet immunology are summarized in Table 2.
Table 2. Principal antigenic targets relevant to platelet immune disorders.

3. Laboratory Methods and Diagnostic Toolbox

3.1. Analytical Strategy and Pre-Analytical Considerations

Laboratory investigation in platelet immunology rarely depends on a single analytical method. Different assays answer different questions: whether platelet-reactive antibodies are present, whether they recognize a defined antigen or glycoprotein, whether the corresponding antigen is genetically present in the relevant individual, and, in selected disorders, whether the detected antibody can activate platelets. A rational diagnostic strategy therefore requires sequential use of screening, specificity, molecular, and functional methods according to the clinical phenotype [7,8,9].
Pre-analytical conditions can substantially influence assay performance. Sample timing, specimen type, anticoagulant, storage conditions, recent transfusion, previous immunomodulatory treatment, platelet count, and the availability and quality of target platelets may all affect analytical sensitivity [9,13,14]. These factors are particularly relevant to intact-cell assays, which depend on preservation of membrane glycoproteins, and to drug-dependent antibody studies, where the implicated drug or an appropriate metabolite may need to remain present during defined stages of the assay [13,27].
The analytical workflow should therefore be sequential. Broad detection may be followed, when required, by specificity assignment, molecular characterization, or functional confirmation. Method selection should depend on the question that remains unresolved at each stage of the investigation [7,8,27].

3.2. Platelet Antibody Detection and Identification

Methods used to investigate platelet-reactive antibodies can be broadly divided into intact-cell assays, glycoprotein-specific methods, and solid-phase or bead-based platforms. These techniques interrogate partly overlapping antibody populations and should be regarded as complementary rather than interchangeable [7,9].
The platelet immunofluorescence test (PIFT), generally performed using flow cytometry, detects immunoglobulin associated with intact platelets. Preservation of the platelet membrane allows broad detection of antibodies directed against multiple surface targets without requiring prior knowledge of specificity. This broad scope is useful for screening, but it also limits specificity. Reactivity may result from HPA antibodies, HLA class I antibodies, platelet autoantibodies, or nonspecific platelet-associated immunoglobulin [9]. External quality-assessment data have shown that laboratories relying exclusively on broad platelet-reactive assays perform less well in platelet-specific antibody identification than laboratories incorporating glycoprotein-specific methods [14].
Glycoprotein-specific assays provide a different level of information. The monoclonal antibody-specific immobilization of platelet antigens (MAIPA) assay remains one of the most established reference methods for characterizing antibodies directed against defined platelet glycoprotein complexes [9,28]. Patient serum is allowed to react with intact platelets before cell lysis. A monoclonal antibody directed against a defined glycoprotein then captures the corresponding antigen–antibody complex, allowing reactivity to be assigned to a particular glycoprotein system. When appropriately selected antigen-positive and antigen-negative platelet panels are used, this approach can support HPA antibody specificity assignment [28].
MAIPA is particularly valuable in FNAIT, PTP, and selected investigations of platelet transfusion refractoriness. It is also used for glycoprotein-specific platelet autoantibody investigation. Its strengths should not, however, be interpreted as absence of analytical limitations. Performance depends on platelet panel composition, antigen expression, the monoclonal antibody used for capture, assay conditions, and technical experience [9,14,28]. Competitive or steric interference between the human antibody and the monoclonal capture antibody may impair detection of particular specificities. Low-frequency antigens create an additional practical difficulty because appropriately typed antigen-positive platelets may not be readily available [9,29].
Commercial multiplex platforms offer a more standardized and rapid approach by testing reactivity against several platelet glycoprotein targets simultaneously. They reduce dependence on locally maintained platelet panels and are easier to integrate into routine laboratory workflows. Their convenience does not eliminate biological or analytical limitations. Antigen repertoires are necessarily restricted, platform sensitivity varies, and immobilized or recombinant targets may not reproduce all clinically relevant native conformational epitopes [7,9].
Direct comparison of MAIPA, PIFT, and a microsphere-based multiplex assay showed that the three approaches did not identify identical antibody repertoires, supporting reflex testing with an independent method when clinical suspicion remains high despite a negative or discordant initial result [7]. The intended use of each platform is equally important. Enten et al. compared the HLA class I component of PAK-LX with dedicated HLA single-antigen bead testing in 137 clinical samples. Thirty-six percent of samples showed discordant results, almost entirely because HLA antibodies detected by SAB were not detected by PAK-LX. The authors therefore concluded that the PAK-LX HLA class I bead should not be used as a stand-alone HLA antibody screening method in suspected immune platelet refractoriness [30].
Platelet autoantibody testing in ITP requires a different interpretive framework. The systematic review and meta-analysis discussed earlier reported pooled sensitivity of approximately 53% and specificity of 93% for direct glycoprotein-specific testing [4]. Under more rigorously defined clinical and laboratory conditions, higher sensitivities have been reported, illustrating the influence of patient selection and methodology on assay performance [31]. International consensus recommendations therefore regard glycoprotein-specific platelet autoantibody testing as potentially useful in selected diagnostically complex cases rather than as a routine assay capable of independently establishing or excluding ITP [10].

3.3. HLA Antibody Testing and Compatibility Assessment

Solid-phase HLA antibody assays have substantially changed the investigation of immune platelet transfusion refractoriness. Screening platforms determine whether HLA antibodies are detectable, whereas single-antigen bead (SAB) assays provide detailed specificity information that can be compared with the HLA profile of potential platelet donors [2,8,11].
The analytical resolution of SAB testing is also its principal interpretive challenge. Mean fluorescence intensity (MFI) is a semiquantitative measure of fluorescence generated within a particular assay system. It should not be interpreted as an absolute antibody concentration or as a direct measure of pathogenicity. Antigen density, bead composition, epitope presentation, serum interference, antibody affinity, assay saturation, prozone-related effects, and technical variability can all influence MFI [8,12].
For this reason, universal MFI thresholds should be applied cautiously. Interpretation should incorporate the patient’s sensitization history, antibody specificity pattern, HLA type, assay behavior, prior transfusion response, and the HLA profile of available donors [8,12]. The relevant clinical question is not simply whether an HLA antibody can be detected, but whether the antibody repertoire provides a biologically plausible explanation for documented platelet transfusion failure.
Once an immune HLA mechanism is supported, several approaches may be used to identify suitable platelet components. These include conventional HLA matching, avoidance of donor antigens corresponding to identified recipient antibodies, virtual compatibility assessment, and physical platelet crossmatching [2,8,11]. The most appropriate strategy depends on the breadth of sensitization, urgency, donor-panel size, laboratory infrastructure, and previous transfusion responses. Analytical compatibility should not be treated as a guarantee of an adequate post-transfusion increment [8,11].

3.4. Molecular HPA and HLA Typing

Molecular typing complements antibody testing by defining the antigenic background against which serologic results are interpreted. Its diagnostic role differs according to the clinical setting. In FNAIT, HPA genotyping can establish maternal–paternal incompatibility and determine whether the fetus or neonate carries the antigen corresponding to the maternal antibody. In platelet transfusion refractoriness, HLA typing provides the recipient antigen profile required for conventional matching, antibody-avoidance strategies, and virtual compatibility assessment [1,2,8,23,24,25,26].
Targeted PCR-based methods remain appropriate when a defined HPA polymorphism must be resolved rapidly. Multiplex methods and sequencing-based approaches can characterize several HPA systems simultaneously and may be more efficient for donor-panel development or complex investigations [23]. Molecular typing is particularly useful when serologic phenotyping reagents are unavailable, when thrombocytopenia limits phenotypic testing, or when recent transfusion could complicate interpretation of a cellular phenotype.
For fetal investigation, analysis of cell-free fetal DNA allows HPA status to be determined noninvasively. PCR, droplet digital PCR, and next-generation sequencing approaches have all been developed, with recent methods incorporating internal markers that help establish whether sufficient fetal DNA was present for a reliable result [24,25].
The principal limitation of genotyping is conceptual rather than analytical: demonstration of an antigen does not demonstrate the presence of an antibody, and demonstration of an antigenic mismatch does not establish pathogenicity. Molecular and serologic results should therefore be interpreted as complementary layers of evidence rather than interchangeable diagnostic findings [22,23].

3.5. Drug-Dependent Platelet Antibody Testing

DITP requires a distinct laboratory strategy because antibody binding may depend on the presence of the implicated drug or one of its metabolites. Laboratory confirmation is based on demonstrating platelet-reactive immunoglobulin under drug-dependent conditions, ideally with absent or substantially lower reactivity when the drug is omitted [13,27].
Flow cytometric and enzyme-based methods may be used. Analytical conditions are critical. Drug concentration, solubility, timing of sample collection, target platelet preparation, incubation conditions, wash buffers, and appropriate positive and negative controls can all influence sensitivity [13]. ISTH recommendations note that EDTA may disrupt some platelet glycoprotein complexes and recommend serum or citrate samples for standardized DITP testing. Samples should, whenever possible, be collected during or close to the acute episode [13].
A negative result does not exclude DITP. False-negative findings may occur when the relevant antibody recognizes a metabolite rather than the parent drug, when the drug is poorly soluble, when in vitro conditions fail to reproduce the biologically relevant interaction, or when sampling occurs after antibody levels have declined [13,27]. Laboratory results must therefore be interpreted together with drug exposure, timing of thrombocytopenia, withdrawal of the suspected agent, and subsequent platelet recovery.

3.6. PF4 Immunoassays and Functional Testing for HIT

The laboratory diagnosis of HIT follows a different conceptual model from conventional platelet alloantibody testing. PF4-dependent immunoassays determine whether antibodies recognizing PF4/polyanion complexes are present, whereas functional assays address whether those antibodies are capable of activating platelets. The two questions are related but not equivalent [6,15].
PF4/heparin immunoassays are generally highly sensitive, but positive results may include antibodies without platelet-activating capacity. Diagnostic specificity improves when immunoassay findings are interpreted in relation to clinical pretest probability and, when required, functional testing [6,15]. The magnitude of immunoassay reactivity may contribute to interpretation, but no laboratory result should be considered independently of the clinical context.
Functional assays include the serotonin release assay (SRA), heparin-induced platelet activation assay (HIPA), platelet aggregation methods, and flow cytometry-based approaches. By directly assessing platelet activation, these methods provide evidence closer to the pathogenic mechanism of HIT. Their technical complexity remains substantial. Donor platelet responsiveness, platelet preparation, heparin concentration, sample handling, activation endpoint, and interpretation criteria may all influence performance [15,16].
Standardization remains an active issue. In 2026, the ISTH Scientific and Standardization Committee published detailed recommendations addressing sample preparation, donor selection, heparin concentrations, controls, analytical interpretation, and assay-specific requirements for functional HIT testing [15]. A companion international survey demonstrated considerable interlaboratory heterogeneity in donor selection, platelet preparation, heparin concentrations, FcγRIIA inhibition controls, and internal quality procedures [16]. Functional HIT assays should therefore not be treated as analytically interchangeable simply because they interrogate the same biological mechanism.

3.7. Quality Assurance and Integrated Reporting

Quality assurance is particularly important in platelet immunology because several assays remain concentrated in specialized laboratories and may depend on biological reagents, typed donor platelets, locally validated thresholds, or laboratory-developed procedures. External quality-assessment data have demonstrated substantial differences between laboratories in platelet antibody screening and specificity assignment, with improved performance when glycoprotein-specific methods form part of the diagnostic strategy [14]. Contemporary HIT standardization studies similarly demonstrate persistent methodological variation and reinforce the need for harmonization and external quality assessment [15,16].
The final laboratory report should extend beyond a binary positive or negative result. Where appropriate, it should identify the method used, antibody specificity, relevant antigenic information, important analytical limitations, and the degree of concordance with the suspected clinical mechanism. Results generated by highly sensitive platforms should not automatically be translated into statements of pathogenicity or causality.
When findings remain inconclusive, the report should indicate the most appropriate next analytical step. Depending on the clinical problem, this may include repeat testing, confirmation using an independent methodology, HPA or HLA typing, testing of relevant family members or platelet donors, functional confirmation, or referral to a specialized reference laboratory.
The laboratory contribution is strongest when interpretation distinguishes three levels of evidence: analytical detection of an antibody, demonstration of a relevant antigenic or mechanistic relationship, and concordance of that finding with the clinical phenotype. The principal laboratory methods, their diagnostic roles, and their analytical limitations are summarized in Table 3. Beyond method selection, practical implementation requires attention to specimen type, sampling relative to clinical events or treatment, assay-specific interferences, and the circumstances in which repeat or alternative testing may be necessary. These pre-analytical and interpretive considerations, including indications for referral to a specialized reference laboratory, are summarized in Table 4.
Table 3. Main laboratory methods used in platelet immunology.
Table 4. Practical pre-analytical and interpretive considerations in platelet immunology. Specimen requirements, stability, anticoagulant compatibility, and analytical conditions may differ between assays and manufacturers. The recommendations summarize general laboratory principles and do not replace locally validated standard operating procedures. When the clinical phenotype remains strongly suggestive of an immune mechanism despite negative or discordant findings, the need for repeat testing, an independent analytical method, or referral to a specialized reference laboratory should be considered in relation to the suspected disorder.

4. Disease-Specific Diagnostic Algorithms and Laboratory Interpretation

The analytical methods described in the preceding section acquire clinical value when they are organized into disease-specific diagnostic sequences. Each pathway begins with verification of the relevant phenotype and estimation of the likelihood of an immune mechanism; additional specificity, molecular, or functional testing is introduced only when it resolves a question left open by the preceding step.
The initial investigation should establish whether thrombocytopenia or platelet transfusion failure is genuine and determine its temporal relationship with pregnancy, transfusion, drug exposure, heparin treatment, infection, bleeding, or other relevant triggers. This information defines the pretest probability of an immune mechanism and determines the most appropriate subsequent laboratory pathway [2,5,6,10,11].
The principal phenotype-driven pathways discussed below are summarized initially in Figure 2, after which the major disorders are considered separately.
Figure 2. Phenotype-directed investigation of suspected immune-mediated platelet disorders. Entry into the diagnostic pathway is based on confirmed thrombocytopenia, a clinically relevant relative platelet count decline, or other findings suggestive of an immune platelet disorder. The clinical setting, timing of platelet changes, transfusion history, pregnancy, and medication exposure guide the selection of disease-specific investigations. Suspected heparin-induced thrombocytopenia requires assessment of clinical pretest probability and should not be excluded solely because the absolute platelet count remains above 150 × 109/L. Nonimmune and immune contributors may coexist, and clinically indicated treatment may proceed in parallel with laboratory investigation. This pathway is an author-integrated synthesis of published diagnostic principles [1,2,3,4,5,6,10,34], not an independently validated clinical decision instrument. DITP, drug-induced immune thrombocytopenia; FNAIT, fetal and neonatal alloimmune thrombocytopenia; HIT, heparin-induced thrombocytopenia; HPA, human platelet antigen; ITP, immune thrombocytopenia; PTP, post-transfusion purpura.

4.1. Platelet Transfusion Refractoriness

Platelet transfusion refractoriness (PTR) is characterized by repeatedly inadequate platelet count increments following transfusion. Although HLA class I alloimmunization is the predominant immune mechanism, poor platelet recovery frequently occurs in patients with clinical conditions that increase platelet consumption or shorten platelet survival. Active bleeding, sepsis, disseminated intravascular coagulation, splenic sequestration, and other inflammatory or consumptive processes may contribute to an inadequate response. These mechanisms are not mutually exclusive. A patient with clinically relevant HLA alloantibodies may simultaneously have infection, hemorrhage, or other factors that impair platelet recovery, making attribution to a single cause inappropriate [2,11,20,26].
The initial laboratory assessment should establish whether the inadequate response is reproducible and whether the transfusion circumstances permit meaningful interpretation. Documentation should include the pre- and post-transfusion platelet counts, sampling intervals, administered platelet dose, component characteristics, ABO compatibility, and relevant clinical factors. CCI remains a conventional measure of platelet recovery because it adjusts the observed increment for recipient body surface area and platelet dose [2,11,26].
The CCI is calculated as follows:
CCI = Post   count   −   Pre   count   ×   Body   Surface   Area   m 2 Platelet   Transfused   × 10 11
For this calculation, platelet counts must be expressed as platelets/µL, body surface area as m2, and the transfused platelet dose as multiples of 1011 platelets. When counts are reported in ×109/L, their numerical values must be converted to platelets/µL before applying the equation. Failure to account for this conversion produces a 1000-fold difference in the calculated result.
The pre-transfusion sample should be collected immediately before, or as close as practicable to, platelet administration. For conventional early CCI assessment, the post-transfusion platelet count is obtained approximately 10–60 min after completion of transfusion. The platelet dose should preferably reflect the actual platelet content documented by the blood establishment. When a nominal component dose is used, this assumption should be recorded because differences in component platelet content may influence the calculated result [2,11].
A CCI below 5000 following two consecutive transfusions is commonly used to identify an inadequate early platelet response, although a threshold of 7500 has also been applied. These operational criteria must be interpreted according to the sampling interval and clinical circumstances. In particular, thresholds established for early post-transfusion assessment should not be applied without qualification to later platelet counts. A reduced CCI demonstrates inadequate platelet recovery but does not identify the responsible immune or nonimmune mechanism [2,11,26,35].
For illustration, consider a patient with a body surface area of 1.8 m2 who receives a platelet component containing 3.0 × 1011 platelets. The platelet count increases from 8 × 109/L to 18 × 109/L at 30 min. After conversion of the increment to 10,000 platelets/µL, the calculated CCI is 6000. This result exceeds the commonly used threshold of 5000 but remains below 7500. Its interpretation therefore depends on the predefined threshold, reproducibility, sampling conditions, and overall clinical context.
The role of routine early CCI assessment has recently been questioned. Glover et al. challenged the continued requirement for a one-hour CCI in the diagnostic workup of platelet refractoriness [35]. This discussion does not establish that post-transfusion platelet measurements are universally unnecessary. Rather, it highlights the limitations of treating a single numerical result as a definitive diagnostic discriminator and raises the question of whether routine measurement consistently changes patient management. Early CCI may still provide useful information about platelet recovery and the response to selected components, but its findings require contextual interpretation.
ABO incompatibility constitutes a distinct immune mechanism of impaired platelet recovery. In major ABO-incompatible platelet transfusions, recipient anti-A or anti-B antibodies may recognize ABO antigens expressed by donor platelets, contributing to accelerated clearance and reduced post-transfusion increments. This mechanism differs from HLA- or HPA-mediated alloimmunization and should not be grouped with nonimmune platelet consumption. Assessment of ABO compatibility should therefore form an explicit component of the investigation, alongside evaluation of clinical consumption and alloimmune mechanisms [2,11,26].
When an immune contribution remains plausible, HLA class I antibody screening and specificity analysis should be interpreted together with the recipient’s HLA profile, sensitization history, previous transfusion responses, and the antigenic characteristics of potential platelet donors. Single-antigen bead assays provide detailed information about HLA antibody specificity, although their high analytical sensitivity introduces important interpretive limitations. Mean fluorescence intensity is affected by antigen density, bead composition, serum interference, antibody affinity, and other platform-dependent variables. It cannot be regarded as an absolute antibody concentration or a direct measure of platelet-destructive activity. Consequently, universal MFI thresholds should not be used to establish clinical relevance independently of the transfusion context [8,12,36].
Once HLA-mediated refractoriness is supported, transfusion strategies may include HLA antigen-matched components, antibody-specific antigen avoidance, epitope-based selection, virtual crossmatching, or physical platelet crossmatching. The choice depends on antibody specificity, the extent of sensitization, donor availability, urgency, laboratory resources, and the patient’s previous responses. These approaches have different practical requirements and evidentiary bases. Analytical compatibility should not be regarded as proof that an adequate platelet increment or improvement in clinical outcomes will follow [2,8,11,36,37,38,39,40].
HPA antibody investigation is appropriate when an additional platelet-specific alloimmune mechanism remains biologically plausible, particularly when HLA antibody findings do not adequately explain the observed refractoriness or when inadequate recovery persists despite appropriately selected components. However, persistent transfusion failure should not automatically trigger increasingly extensive antibody testing without reassessment of clinical consumption, ABO compatibility, component characteristics, and the response to previous transfusions [2,9,11].
The investigation should remain iterative. Identification of a nonimmune contributor does not exclude concurrent alloimmunization, and the demonstration of alloantibodies does not establish that they are the principal cause of transfusion failure. Continued poor recovery following apparently compatible transfusions should prompt renewed evaluation of clinical circumstances, antibody findings, and alternative compatibility strategies. The principal laboratory objective is to determine whether the immunological evidence provides a sufficiently plausible explanation for the observed transfusion response to support an appropriate change in transfusion management [2,8,11]. This sequence is summarized in Figure 3.
Figure 3. Integrated laboratory investigation of platelet transfusion refractoriness. Repeated inadequate platelet recovery is assessed using appropriately timed post-transfusion measurements, component information, and clinical findings. Evaluation includes nonimmune causes of consumption or sequestration, ABO incompatibility as a distinct immune contributor, and HLA- or HPA-mediated alloimmunization. These mechanisms may coexist. Identification of one contributing factor does not necessarily exclude investigation of another. When HLA-mediated refractoriness is supported, antibody characterization and recipient/donor HLA information may guide selection of compatible components. Persistent inadequate recovery prompts reassessment of clinical circumstances, previous component selection, and the need for HPA or additional compatibility testing. The pathway is an author-integrated interpretation of established approaches [2,8,11,26,35], and has not been independently validated. CCI, corrected count increment; HLA, human leukocyte antigen; HPA, human platelet antigen.

4.2. Fetal and Neonatal Alloimmune Thrombocytopenia

The laboratory diagnosis of FNAIT relies on demonstrating a biologically plausible maternal-fetal alloimmune interaction. A complete investigation typically combines maternal platelet antibody testing with maternal and paternal HPA genotyping and, where appropriate, fetal or neonatal HPA determination [1,24,25,41].
Glycoprotein-specific serology remains central to antibody identification. Current FNAIT recommendations continue to support investigation in specialized laboratories using methods such as MAIPA, particularly because glycoprotein-specific approaches facilitate identification of clinically relevant platelet antibodies while reducing interference from maternal HLA class I antibodies [1]. Parental genotyping establishes whether the implicated antigen is absent from the mother and present in the father and can help define inheritance risk in the current or subsequent pregnancy. Molecular typing therefore complements rather than replaces serologic evidence.
When routine antibody investigation is negative despite a convincing clinical phenotype, investigation should not necessarily stop. Maternal–paternal platelet crossmatching in a reference laboratory may detect antibodies against low-frequency or private paternal antigens. In addition, some clinically relevant antibodies may be initially undetectable, making repeat or delayed testing informative in selected unresolved cases [1].
Noninvasive fetal HPA genotyping using cell-free fetal DNA has expanded the molecular component of FNAIT investigation. PCR-based, digital PCR, and next-generation sequencing approaches can determine fetal antigen status without invasive fetal sampling, particularly when the father is heterozygous for the relevant antigen [24,25]. Contemporary approaches increasingly integrate molecular and serologic evidence rather than treating either as independently sufficient for diagnosis [41].
Diagnostic interpretation requires integration of maternal platelet antibody specificity, maternal and fetal HPA profiles, and the observed clinical phenotype. Identification of an antibody directed against an antigen absent from the mother and expressed by the fetus provides evidence of a biologically plausible alloimmune interaction. However, this relationship does not independently establish that the antibody caused thrombocytopenia or predict the severity of fetal or neonatal disease. The strength of the causal inference depends on the antibody specificity, the quality of the immunohematological evidence, the clinical presentation, and the exclusion of competing explanations [1,17,41,42].
The distinction is particularly important for anti-HPA-5b. Anti-HPA-1a is a well-established cause of severe FNAIT, whereas the clinical significance of anti-HPA-5b remains controversial. Although anti-HPA-5b antibodies have been identified in pregnancies investigated for suspected FNAIT, their detection does not establish that they are responsible for the observed thrombocytopenia. Recent recommendations have questioned whether the available evidence convincingly supports a causal role for HPA-5b immunization in fetal thrombocytopenia [1]. The presence of a compatible fetal antigen should therefore be interpreted as evidence of potential antigenic recognition, not as proof of antibody pathogenicity.
This uncertainty is reflected in contemporary clinical practice. In a 2026 survey of United Kingdom fetal medicine centers, 13 of 16 respondents (81.3%) favored weekly intravenous immunoglobulin for a standardized subsequent-pregnancy scenario involving anti-HPA-5b antibodies without previous intracranial bleeding, despite the continuing debate surrounding the pathogenic significance of this specificity [43]. These findings describe clinical management preferences rather than evidence that anti-HPA-5b causes thrombocytopenia or that treatment improves outcomes in this particular setting. The distinction between precautionary clinical intervention and demonstration of immunological causality is important, especially when recommendations for subsequent pregnancies rely on the interpretation of a previous suspected alloimmune event.
Molecular characterization contributes essential information but has its own interpretive boundaries. Maternal and paternal HPA genotyping can establish whether a relevant antigenic mismatch is possible. Noninvasive fetal genotyping may clarify fetal antigen status, particularly when the father is heterozygous for the implicated allele. Nevertheless, fetal antigen positivity does not establish the presence of a pathogenic antibody or predict clinical severity. Serological investigation and parental genotyping may therefore be undertaken in parallel, with fetal or neonatal typing introduced when it is expected to resolve a clinically meaningful question [1,17,24,25,41].
When routine investigations are negative despite a convincing clinical phenotype, further evaluation in a specialized reference laboratory may be justified. Depending on the suspected mechanism, this may include repeat antibody testing, investigation using alternative glycoprotein-specific methods, maternal–paternal platelet crossmatching, or expanded HPA characterization. Negative initial serology does not invariably exclude FNAIT, particularly when the antibody concentration is low, the implicated antigen is poorly represented in routine testing panels, or the relevant specificity is not detected by the initial assay [1,9,42].
These limitations emphasize the need to distinguish analytical detection, antigenic concordance, and clinical causality. A diagnostic conclusion should reflect the strength of the available evidence for the particular HPA specificity, rather than treating all detectable platelet alloantibodies as biologically equivalent. The proposed laboratory investigation is summarized in Figure 4, with particular emphasis on parallel testing, interpretation of discordant findings, and specificity-dependent diagnostic confidence. The proposed laboratory investigation is summarized in Figure 4, with particular emphasis on parallel testing, interpretation of discordant findings, and specificity-dependent diagnostic confidence.
Figure 4. Integrated serological and molecular investigation of suspected fetal and neonatal alloimmune thrombocytopenia. Maternal platelet antibody investigation and parental HPA genotyping may be undertaken in parallel. Fetal or neonatal HPA typing is introduced when relevant to establishing the antigenic context of a detected antibody or resolving an uncertain diagnosis. Discordant or initially negative findings may justify repeat testing, alternative glycoprotein-specific methods, maternal–paternal platelet crossmatching, or referral to a specialized laboratory. The interpretation of antibody–antigen concordance must account for specificity-dependent evidence of pathogenicity, particularly the unresolved clinical significance of anti-HPA-5b. Urgent neonatal management should not await completion of the immunohematological investigation. The pathway is an author-integrated synthesis based on published recommendations [1,9,17,24,25,41,42] and has not undergone independent prospective validation. FNAIT, fetal and neonatal alloimmune thrombocytopenia; HPA, human platelet antigen.

4.3. Post-Transfusion Purpura

Post-transfusion purpura should be considered when profound thrombocytopenia develops several days after transfusion, particularly when the severity and timing of the platelet fall are not adequately explained by bleeding, infection, disseminated intravascular coagulation, HIT, DITP, or another cause [3]. As PTP is uncommon, clinical context and temporal concordance are particularly important.
Laboratory confirmation is based on identification of a platelet-specific alloantibody together with determination of the patient’s HPA phenotype or genotype. Anti-HPA-1a accounts for a substantial proportion of well-characterized cases, although antibodies against other HPA systems have also been reported [3].
Broad platelet reactivity or concomitant HLA antibodies should not, by themselves, be considered diagnostic of PTP. Stronger immunohematological evidence is provided by identification of a platelet-specific alloantibody directed against an HPA antigen absent from the patient’s own platelets, together with a clinically compatible post-transfusion presentation. For example, anti-HPA-1a in a patient with an HPA-1b/1b genotype establishes an antigen–antibody relationship consistent with HPA-1a alloimmunization. Nevertheless, the demonstration of this relationship alone does not establish that the antibody is responsible for the acute thrombocytopenic episode [3,9,21].
Glycoprotein-specific antibody identification, preferably supported by an appropriately characterized platelet panel, is particularly important in this setting. MAIPA or another validated glycoprotein-specific method can help distinguish HPA-directed alloantibodies from broad platelet reactivity attributable to HLA antibodies or nonspecific immunoglobulin binding. Molecular HPA typing provides complementary evidence by establishing the patient’s antigen-negative status for the implicated specificity [3,9,23,28].
Although PTP is classically associated with alloantibodies against an antigen absent from the patient’s platelets, the mechanism responsible for the profound destruction of autologous platelets remains incompletely understood. Proposed explanations include immune complexes, antibody binding to platelet-associated antigenic material, and other mechanisms capable of extending platelet destruction beyond antigen-positive transfused cells. These hypotheses should be distinguished from the directly demonstrable laboratory findings. Accordingly, the diagnostic report should identify the alloantibody, document the relevant HPA genotype, assess temporal concordance with transfusion, and acknowledge any remaining uncertainty concerning causality [3].

4.4. Immune Thrombocytopenia

ITP differs fundamentally from alloimmune platelet disorders because no laboratory test independently establishes or excludes the diagnosis. It remains predominantly a clinical diagnosis based on thrombocytopenia, appropriate clinical assessment, peripheral blood findings, and exclusion of alternative explanations [10,44].
Glycoprotein-specific platelet autoantibody testing can provide supportive evidence of an immune mechanism, but its diagnostic performance depends substantially on the analytical approach. Direct assays investigate immunoglobulins associated with the patient’s platelets, whereas indirect assays detect circulating platelet-reactive antibodies in serum or plasma using an appropriate platelet target. These approaches evaluate different antibody compartments and should not be considered analytically interchangeable [4,9,10].
The distinction is clinically relevant. In a systematic review and meta-analysis, Vrbensky et al. reported pooled sensitivity of 53% and specificity of 93% for direct glycoprotein-specific autoantibody testing. Indirect assays showed lower pooled sensitivity, approximately 18%, with specificity of approximately 96% [4]. Consequently, negative results obtained using either approach cannot reliably exclude ITP. Positive results may support the diagnosis in an appropriate clinical context, but their interpretation must consider the assay methodology, antigenic targets, and possibility of alternative immune platelet disorders.
More favorable diagnostic performance has been reported under carefully standardized laboratory conditions and with more restrictive clinical definitions of ITP [31]. These findings do not necessarily contradict the broader pooled estimates. Rather, they demonstrate that patient selection, diagnostic reference standards, specimen characteristics, platelet preparation, and antigen-specific capture methods can influence the apparent sensitivity of platelet autoantibody testing. The performance observed in an experienced reference laboratory should not automatically be extrapolated to routine testing performed using different platforms.
Broad platelet-associated immunoglobulin measurements require particular caution. They may detect immunoglobulin binding unrelated to pathogenic platelet autoantibodies and do not provide the same specificity information as glycoprotein-directed assays. Similarly, a positive indirect test may reflect circulating alloantibodies rather than platelet autoreactivity unless the relevant antigenic and clinical context is established [4,9,10].
From a diagnostic perspective, the unresolved challenge is not simply to increase antibody detection. It is to determine whether immunological findings can improve diagnostic classification in patients with atypical thrombocytopenia, distinguish ITP from alternative disorders, or contribute to clinically useful patient stratification. At present, these potential applications require further validation. The laboratory report should therefore identify whether testing was direct or indirect, specify the analytical method and glycoprotein targets, and present a positive result as supportive rather than independently diagnostic evidence [4,10,31].

4.5. Drug-Induced Immune Thrombocytopenia

Drug-induced immune thrombocytopenia (DITP) requires careful evaluation of the temporal relationship between medication exposure and the onset of thrombocytopenia. At presentation, the assessment should document the suspected drug, duration and timing of exposure, platelet count trajectory, severity of thrombocytopenia, and potential alternative explanations. The investigation should distinguish evidence available during the acute episode from findings that can only be established during subsequent clinical follow-up [5,13,27,33].
When specialized drug-dependent antibody testing is indicated, an appropriate specimen should be collected as early as practicable, preferably during or close to the acute episode. Sample collection and referral should not be postponed until platelet recovery has occurred. Early sampling is particularly important because antibody concentrations, drug exposure conditions, and the availability of relevant metabolites may influence the possibility of laboratory confirmation [13,27].
Clinical management must proceed independently of the completion of specialized testing. Withdrawal of a strongly suspected causative medication should not await demonstration of drug-dependent platelet antibodies. Subsequent platelet recovery following withdrawal provides additional evidence supporting the suspected diagnosis, but improvement alone does not establish an immune mechanism. Laboratory confirmation requires demonstration of antibody reactivity under appropriate drug-dependent conditions, interpreted alongside the clinical history and the known limitations of the assay [5,13,27,33].
A convincing laboratory result requires demonstration of platelet-reactive immunoglobulin in the presence of the implicated drug, with absent or substantially reduced reactivity under appropriate drug-free conditions [13,27]. International standardization recommendations emphasize the importance of specimen type, drug concentration, controls, platelet preparation, incubation conditions, and assay design [13].
Analytical sensitivity remains incomplete. Some antibodies recognize a metabolite rather than the parent compound, some drugs cannot readily be reproduced at biologically relevant concentrations in vitro, and antibody levels may decline after the acute episode [13,27]. A negative assay therefore cannot exclude DITP.
This limitation should be reflected explicitly in the interpretive report. The laboratory should distinguish between failure to demonstrate a drug-dependent antibody and evidence against a drug-related immune mechanism; these statements are not equivalent.

4.6. Heparin-Induced Thrombocytopenia

Heparin-induced thrombocytopenia (HIT) is an immune-mediated prothrombotic disorder in which antibodies recognizing complexes of platelet factor 4 (PF4) and polyanions may promote platelet activation through FcγRIIA-dependent mechanisms. Laboratory diagnosis requires integration of clinical probability, PF4-dependent antibody detection, and, when indicated, functional evidence of platelet activation. These components provide different levels of diagnostic information and cannot be interpreted interchangeably [6,15,34].
Clinical suspicion should not depend exclusively on an absolute platelet count below 150 × 109/L. A substantial relative decrease from the preceding platelet count, particularly a fall exceeding 50%, may be clinically significant even when the resulting count remains within the conventional reference range. The timing of thrombocytopenia in relation to heparin exposure, previous exposure, new thrombosis, and alternative explanations must be considered before laboratory testing is requested [6,34].
The 4Ts score provides a structured assessment of pretest probability using four clinical domains: the magnitude of thrombocytopenia, timing of platelet count reduction, thrombosis or other characteristic manifestations, and alternative causes of thrombocytopenia. Scores of 0–3, 4–5, and 6–8 correspond to low, intermediate, and high probability, respectively. In patients with a reliably established low-probability score, routine HIT testing is generally discouraged because false-positive immunoassay results may lead to inappropriate diagnosis and unnecessary changes in anticoagulant therapy. When relevant information is missing or the score cannot be reliably established, clinical reassessment may be necessary [6,34].
Patients with intermediate or high pretest probability should undergo PF4-dependent immunoassay testing. In these circumstances, clinical management should not be delayed while laboratory results are pending. Decisions concerning heparin discontinuation and the introduction and intensity of non-heparin anticoagulation should follow established clinical recommendations, taking account of thrombotic and bleeding risks [6,34].
PF4-dependent immunoassays provide sensitive detection of antibodies directed against PF4/polyanion complexes. However, their diagnostic specificity varies according to assay design, antibody class, and analytical characteristics. Positive results may reflect antibodies that do not produce clinically relevant platelet activation. The magnitude of immunoassay reactivity contributes to diagnostic interpretation, particularly for quantitative or semiquantitative enzyme immunoassays, but numerical results should not be transferred directly between analytical platforms without validation [6,32].
A negative result obtained using an appropriately sensitive immunoassay substantially reduces the probability of HIT. In most patients, this supports reconsideration of the diagnosis and reassessment of anticoagulation according to established guidelines. Exceptionally strong clinical suspicion despite a negative immunoassay requires renewed evaluation of the 4Ts assessment, specimen identity and quality, assay characteristics, and possible alternative diagnoses before additional investigations are considered [6,34].
Functional platelet activation assays address a different diagnostic question: whether the patient’s antibodies are capable of activating platelets under defined experimental conditions. The serotonin release assay (SRA), heparin-induced platelet activation assay (HIPA), and other validated functional methods provide evidence more directly related to the pathogenic mechanism. Their performance nevertheless depends on donor platelet responsiveness, platelet preparation, heparin concentrations, analytical controls, activation endpoints, and the technical characteristics of the method [15,16].
A positive functional assay in a patient with compatible clinical findings and supporting immunoassay results provides strong evidence for HIT. A negative functional result generally argues against the diagnosis. Nevertheless, uncommon discordant cases require careful interpretation, particularly when clinical probability is high and immunoassay reactivity is strongly positive. In these circumstances, reassessment of the functional method and referral to an experienced reference laboratory may be appropriate. Current guidelines also recognize that functional confirmation may not always be necessary when the clinical probability is high and the immunoassay result is very strongly positive, depending on the analytical platform and clinical context [6,34].
Recent international standardization efforts have highlighted the continuing limitations of functional testing. The 2026 ISTH-SSC recommendations address donor platelet selection, specimen preparation, heparin concentrations, controls, and interpretation of functional assay results [15]. An accompanying international survey documented substantial differences in laboratory practice, including variation in platelet preparation, assay conditions, FcγRIIA inhibition controls, and internal quality procedures [16]. These observations reinforce the importance of standardized protocols, appropriate controls, method validation, and external quality assessment.
Rapid automated immunoassays may reduce diagnostic turnaround time and facilitate the integration of laboratory results into clinical pathways. Comparative studies have also explored the combined interpretation of different immunoassay platforms to improve diagnostic discrimination. Nevertheless, an improvement in laboratory classification should not automatically be equated with demonstrated improvement in clinical outcomes, and assay-specific performance must be considered when interpreting apparently discordant results [32].
The principal unresolved challenge is therefore not simply the detection of anti-PF4 antibodies. It is the reliable distinction between non-pathogenic immunological reactivity and clinically significant platelet activation in circumstances where both missed diagnoses and inappropriate treatment may have serious consequences. Structured pretest probability assessment, assay-specific interpretation, functional testing when indicated, and timely communication between the laboratory and clinical team remain essential. The diagnostic pathway must support clinical action without implying that urgent management should await completion of all laboratory investigations [6,15,16,34].

5. Translating Laboratory Findings into Transfusion Support and Clinical Action

The clinical relevance of platelet immunology ultimately depends on whether laboratory findings alter patient management. In some disorders, antibody specificity and antigen status directly influence blood component selection. In others, the laboratory result changes drug exposure, anticoagulant management, or future transfusion planning without identifying a specific compatible platelet product. The purpose of this section is therefore to define the clinical or transfusion action that follows from a sufficiently supported laboratory interpretation [1,2,6,8,11].
This distinction is particularly important because platelet transfusion itself should not be driven by an immunologic result in isolation. The 2025 AABB and International Collaboration for Transfusion Medicine Guidelines evaluated 21 randomized trials and 13 observational studies and generally supported restrictive platelet transfusion strategies across several clinical settings, with transfusion decisions remaining dependent on bleeding risk and the overall clinical context [45].

5.1. Immune Platelet Transfusion Refractoriness

In immune platelet transfusion refractoriness, the purpose of immunologic investigation is not merely to demonstrate alloimmunization but to identify platelet units with a lower probability of antibody-mediated clearance. HLA class I antibodies account for the majority of immune-mediated cases, whereas HPA antibodies represent a substantially smaller proportion [2,11,20,26,46].
Several donor-selection strategies are available. HLA antigen matching minimizes conventional donor–recipient HLA disparity; antibody specificity-based selection excludes donor antigens targeted by the recipient’s antibody repertoire; physical platelet crossmatching tests the compatibility of individual donor–recipient combinations; and more recent approaches incorporate HLA epitope or eplet compatibility [2,8,11,46].
Evidence does not support treating these approaches as universally interchangeable. A classic observational study of 1621 transfusions in 114 patients found similar platelet recovery after HLA-matched, crossmatch-compatible, and antibody-specificity-selected platelets, with all three outperforming randomly selected units [37]. Conversely, subsequent retrospective data have shown that clinical factors can substantially attenuate the benefit of both HLA-matched and crossmatch-compatible transfusions, reinforcing the importance of nonimmune contributors to refractoriness [38].
More sophisticated matching strategies have also been evaluated prospectively. In a randomized, double-blind, crossover trial involving 49 alloimmunized refractory patients, HLA epitope-matched platelets were noninferior to conventional HLA antigen-matched platelets for the 1 h post-transfusion platelet increment. Increasing numbers of epitope mismatches were associated with a lower probability of an adequate increment [39]. Epitope-based matching may therefore enlarge the effective donor pool when conventional high-grade HLA matches are difficult to identify.
Virtual compatibility approaches provide another option. A prospective cohort using HLA antibody profiles, donor HLA typing, and an epitope-based virtual crossmatch achieved satisfactory 24 h corrected count increments in most transfusions, although the study was small and the approach did not address HPA incompatibility [40]. These technologies are promising, but their role should not be presented as fully standardized routine practice.
The interpretation of HLA antibodies also requires restraint. Sensitive solid-phase methods detect low-level antibodies that are not necessarily associated with transfusion failure. Analysis of TRAP study participants demonstrated that weak to moderate HLA antibodies detectable only by more sensitive modern assays did not reliably predict refractoriness [36]. This supports the principle that laboratory sensitization and clinically relevant immune refractoriness are not synonymous.
A 2026 review of immune PTR similarly emphasizes the integration of clinical assessment, HLA antibody testing, molecular HLA typing, and crossmatching, with compatible components selected through HLA matching, antibody-specific antigen avoidance, or crossmatching according to the individual case [46]. Importantly, real-world practice remains heterogeneous. A 2026 multicenter survey found substantial variation in diagnostic thresholds, knowledge of HLA testing platforms, calculated panel-reactive antibody (cPRA) use, and triggers for specialized platelet support [18].
The laboratory report should therefore avoid presenting an isolated HLA antibody result or MFI value as an automatic indication for specialized platelets. The appropriate sequence remains documented refractoriness → assessment of nonimmune causes → clinically relevant alloantibody characterization → donor-selection strategy → reassessment of post-transfusion response.
HPA-directed support should be considered when a clinically concordant HPA antibody is identified, particularly when HLA findings fail to explain persistent immune refractoriness. Antigen-negative or HPA-compatible platelets may then provide effective support, although the evidence base is considerably smaller than for HLA-mediated refractoriness [11,22,23].

5.2. FNAIT: Translating Maternal Alloimmunization into Neonatal Support

FNAIT provides a clear example of laboratory findings directly influencing platelet selection. Demonstration of a maternal HPA alloantibody together with fetal or neonatal expression of the corresponding antigen establishes the rationale for HPA-compatible neonatal transfusion [1,17,41].
International evidence-based recommendations developed by the ICTMG specifically state that HPA-selected platelets should ideally be available at delivery for infants at risk of FNAIT. If HPA-selected platelets are not immediately available, however, unselected platelets should be transfused rather than delaying clinically necessary treatment [42].
Direct clinical evidence supports the biological rationale for matching. In a multicenter cohort involving 389 neonates with FNAIT, 207 received platelet transfusion. HPA-matched transfusions produced larger platelet increments than unmatched transfusions, although the effect on bleeding outcomes could not be established definitively [47].
The 2025 FNAIT update reaches a similar practical conclusion: antigen-compatible platelets are preferable when readily available, but transfusion of nonselected platelets remains appropriate when urgent support is required [1]. The same review emphasizes that no current laboratory parameter can reliably predict the severity of thrombocytopenia or intracranial hemorrhage in an antigen-positive fetus or neonate.
Laboratory findings also have implications beyond the current pregnancy. Maternal antibody specificity, maternal and paternal HPA genotype, and fetal or neonatal antigen status should be retained because they inform risk assessment and preparation for subsequent pregnancies [1,24,25,41,42]. The international Delphi consensus published in 2025 further illustrates that several aspects of screening, risk stratification, and management remain incompletely standardized across countries [17].

5.3. Post-Transfusion Purpura

PTP represents a different relationship between antibody identification and transfusion support. Although the syndrome is usually associated with a strong HPA alloantibody, transfusion of antigen-negative platelets does not reliably produce a satisfactory increment during the acute phase. IVIG remains the principal therapeutic intervention, while platelet transfusion is generally reserved for clinically significant or life-threatening bleeding [3].
This apparently paradoxical behavior probably reflects the fact that PTP involves destruction of autologous as well as transfused platelets. Consequently, platelet antigen selection does not solve the acute immune mechanism in the same way that HLA-compatible support may improve immune PTR.
The longer-term relevance of the laboratory diagnosis lies mainly in future transfusion planning. Identification of the responsible HPA antibody and the patient’s antigen status permits the result to be documented for future transfusion episodes. Although recurrent PTP is uncommon, HPA-compatible components should be considered, when feasible, in patients with a previous well-established episode [3].
The evidence base for PTP remains dominated by case reports and case series because of the rarity of the disorder.

5.4. Immune Thrombocytopenia

ITP illustrates why antibody identification does not necessarily lead to antigen-directed platelet selection. Platelet autoantibodies recognize the patient’s own platelet glycoproteins, so HLA- or HPA-matched products do not address the underlying pathogenic mechanism [4,10,31].
Platelet transfusion in ITP is therefore determined principally by bleeding severity and clinical urgency. The 2026 guideline on emergency management of critical bleeding in ITP recommends platelet transfusion as part of multimodal emergency therapy together with immune-directed treatment, although the authors explicitly acknowledge that much of the evidence is of low or very low certainty [48].
This recommendation should not be interpreted as evidence that platelet transfusion is routinely required in ITP. It refers specifically to critical bleeding, where immediate hemostatic benefit may outweigh the short survival of transfused platelets.
The broader ITP management landscape was also updated in the 2026 ASH guideline for initial and second-line adult treatment [49]. For the purposes of this review, however, its main relevance is contextual: platelet antibody testing remains supportive rather than determinative, and transfusion decisions remain clinical rather than serologically driven.

5.5. Drug-Induced Immune Thrombocytopenia

The actionable laboratory finding in DITP is the relationship between the antibody and the implicated drug. Once a plausible drug-dependent antibody is demonstrated, the main intervention is withdrawal and subsequent avoidance of the drug rather than antigen-based platelet selection [5,13,27].
The pathophysiology of DITP is heterogeneous. Drug-dependent antibodies may recognize platelet glycoproteins only when the drug is present; other mechanisms involve drug-specific structural changes, naturally occurring antibodies, immune complexes, or antibodies directed against drug-modified targets [33]. This mechanistic heterogeneity explains why the laboratory report should identify the drug tested and the conditions under which antibody reactivity was demonstrated.
A practical clinical approach also emphasizes the timing of drug exposure, recovery after withdrawal, exclusion of competing causes, and, where available, laboratory demonstration of a drug-dependent antibody [29].
Platelet transfusion may be ineffective while substantial concentrations of the offending drug or metabolite remain in the circulation. The 2022 review by Marini et al. notes that platelet recovery generally begins after drug elimination and that platelet transfusion may fail until the drug or metabolite is cleared; IVIG may be considered when severe thrombocytopenia is accompanied by bleeding or a high bleeding risk [5].
The laboratory result should therefore be translated into drug avoidance and documentation, not into routine selection of HPA-compatible platelets.

5.6. Heparin-Induced Thrombocytopenia

HIT changes clinical management through anticoagulant decisions rather than through platelet antigen matching. The consequences of a false-positive laboratory diagnosis are therefore considerable, because unnecessary labeling of HIT can alter anticoagulant therapy, procedural planning, and future heparin exposure.
ASH guidelines recommend that clinical pretest probability and laboratory evidence be integrated before a diagnosis is assigned [6]. The 2024 third edition of the British Society for Haematology guideline provides an independent contemporary framework covering laboratory diagnosis, functional testing, non-heparin anticoagulation, direct oral anticoagulants, autoimmune HIT, IVIG, and plasma exchange [34].
Platelet transfusion is generally not used prophylactically in acute HIT at average bleeding risk because thrombosis is the dominant clinical problem. It may nevertheless be appropriate when active significant bleeding or substantial procedural bleeding risk is present [6,34].
The recent 2026 ISTH recommendations on functional HIT testing further strengthen the need to distinguish immunoassay positivity from demonstration of platelet activation [15,16]. This distinction should be carried through to the clinical report: detection of anti-PF4/polyanion antibodies and demonstration of platelet-activating antibodies are not equivalent laboratory findings.

5.7. Integrated Reporting, Documentation, and Continuity of Care

A specialized platelet immunology result has limited value if it is not translated into information that can be acted upon by the transfusion service or clinical team. The final report should therefore distinguish the analytical result from its clinical interpretation and from any recommended transfusion or management action.
For immune PTR, the report should describe the relevant HLA or HPA antibody pattern and the rationale for donor selection rather than simply reporting antibody positivity [2,8,11,46]. For FNAIT, maternal antibody specificity should be integrated with parental and fetal or neonatal HPA status [1,42]. For DITP, the tested drug and conditions under which reactivity was demonstrated should be specified [13,27,33]. For HIT, immunoassay detection and functional platelet activation should be reported as distinct levels of evidence [6,15,16].
Durable documentation is also important. Clinically significant HPA alloantibodies, previous FNAIT or PTP, complex HLA sensitization associated with refractory transfusion, confirmed DITP, and HIT may influence care years after the initial investigation.
A clinically useful laboratory report should therefore make four elements explicit: the laboratory finding, its biological interpretation, its principal limitation, and the action that follows from it. These disorder-specific relationships are summarized in Table 5.
Table 5. Translation of immunologic findings into transfusion and clinical action.
An example of integrated reporting in suspected immune platelet transfusion refractoriness is provided below. The report is hypothetical and is intended to illustrate the structure of laboratory interpretation rather than represent a validated diagnostic classification.
  • Laboratory finding: HLA class I antibodies have been identified, with specificity directed against antigens expressed by a subset of potential platelet donors. The patient has experienced repeatedly inadequate post-transfusion platelet count increments.
  • Immunological interpretation: The antibody repertoire provides a biologically plausible explanation for an immune contribution to platelet transfusion refractoriness, particularly when the corresponding antigens are present on previously transfused components. However, antibody detection alone does not establish that alloimmunization is the predominant cause of poor platelet recovery.
  • Analytical and clinical limitations: HLA antibody mean fluorescence intensity is semiquantitative and should not be interpreted as a direct measure of antibody pathogenicity. Concurrent clinical factors, including infection, bleeding, inflammatory platelet consumption, or ABO incompatibility, may also impair platelet recovery. These mechanisms should be assessed independently of the serological findings.
  • Recommended laboratory-supported action: Where an immune contribution is considered clinically relevant, selection of HLA-compatible, antibody-avoidance, or crossmatch-compatible platelet components may be appropriate according to donor availability and local laboratory capabilities. Post-transfusion response should be documented, and persistent inadequate recovery should prompt reassessment of both immune and nonimmune contributors [2,8,11,12,35,36,37,38,39,40,46].
This example illustrates the distinction between reporting an analytical result and assigning clinical causality. The laboratory does not merely establish whether an antibody is detectable; it provides an interpretation of the evidence, communicates uncertainty, and identifies a proportionate next step. Comparable principles apply to FNAIT, PTP, DITP, and HIT, although the relevant biological relationships and therapeutic consequences differ substantially across these conditions.

6. Emerging Technologies and Translational Priorities

Technological development in platelet immunology is increasingly directed toward three persistent limitations of current laboratory practice: dependence on biological donor material, restricted analytical multiplexing, and difficulty translating highly sensitive antibody or molecular data into clinically meaningful compatibility. New platforms can now characterize substantially more antigenic and genetic information than was possible with conventional serology or targeted genotyping. The relevant question, however, is no longer simply whether additional information can be generated. It is whether that information improves diagnostic certainty, identifies compatible donors more efficiently, predicts clinically meaningful immune interactions, or changes patient management.
Emerging technologies should therefore be assessed along a translational continuum that includes analytical validity, interlaboratory reproducibility, operational integration, and demonstration of clinical utility. A platform that increases molecular or serologic resolution without improving diagnostic classification, compatible-donor identification, turnaround time, or patient management may offer limited additional clinical value.

6.1. High-Throughput Molecular Typing and Genotyped Donor Registries

Targeted PCR-based HPA genotyping remains appropriate for many routine investigations, particularly when the antigen system of interest is already known. Its major limitation is scalability. Large platelet donor programs increasingly require simultaneous characterization of multiple HPA and HLA loci, creating a clear rationale for multiplex and sequencing-based methods [23,50].
NGS-based HPA typing has demonstrated very high analytical concordance with established single-nucleotide variant methods. A systematic review and meta-analysis of six studies reported pooled agreement of 99.8% for the principal HPA systems evaluated. Importantly, several discordant results resulted from allele dropout in comparator PCR assays rather than from incorrect NGS calls [50]. Nevertheless, the same review identified substantial barriers to stand-alone routine implementation, including instrument and reagent costs, data storage, variant calling, bioinformatic infrastructure, and the availability of appropriately trained staff.
More recent approaches combine platelet and HLA typing within the same workflow. He et al. developed a multiplex PCR-NGS method for simultaneous HLA-A, HLA-B, HLA-C, and HPA genotyping. Among 386 specimens, results were fully concordant with the comparator methods used in the study, while the sequencing strategy additionally identified novel HLA alleles and sequence variants [51]. Long-read sequencing provides another potential advantage by allowing larger genomic regions and phased variants to be resolved directly. PacBio long-read sequencing has been applied to simultaneous HLA class I and HPA genotyping, demonstrating the feasibility of integrated high-resolution platelet donor characterization [52].
NGS is not the only route toward large-scale donor characterization. In 2026, Zhu et al. described a MALDI-TOF mass spectrometry assay incorporating extensive HPA genotyping within a broader immunogenetic panel. Application to 8100 blood donors demonstrated the scalability of this approach for establishing extensively characterized platelet donor databases and identifying rare HPA alleles [53]. A second 2026 study used multiplex multicolor melting curve analysis to determine HLA cross-reactive groups and 14 HPA systems in six reaction tubes. Validation in 200 donors showed complete concordance with NGS for HLA cross-reactive groups and 95.5% to 100% concordance with comparator HPA genotyping, depending on the antigen system [54].
These data suggest that the future molecular laboratory is unlikely to depend on a single universal platform. A more realistic model is fit-for-purpose molecular testing: targeted PCR for rapid resolution of defined questions, scalable multiplex technologies for donor registries, and sequencing when high resolution, rare variants, complex genomic structure, or novel allele identification justify the additional complexity.

6.2. Noninvasive Fetal HPA Genotyping

Noninvasive fetal HPA genotyping is one of the clearest examples of molecular innovation already approaching direct clinical implementation. Cell-free fetal DNA in maternal plasma permits fetal antigen status to be established without invasive fetal sampling, which is particularly valuable when the father is heterozygous for the implicated HPA allele [24,25].
The field has progressed from targeted real-time PCR toward droplet digital PCR and sequencing-based strategies. Targeted methods remain attractive when a single defined antigen must be investigated rapidly, whereas broader platforms offer advantages when several HPA systems need to be considered or when fetal DNA fractions are low [24].
The UMI-NGS method reported by Bertrand et al. combined HPA genotyping with 48 fetal DNA markers, allowing genotype determination and evidence of fetal DNA representation to be obtained from the same analysis [25]. This design addresses an important analytical problem. An apparently negative fetal genotype can only be interpreted confidently when the assay demonstrates that a sufficient fetal DNA fraction was actually interrogated.
The next step in this field should therefore not simply be greater multiplexing. Assays should incorporate internal measures of fetal DNA adequacy, standardized criteria for indeterminate results, external quality assessment, and validation across pregnancies with different fetal fractions and clinically relevant HPA specificities. Noninvasive fetal HPA testing illustrates a broader principle for molecular laboratory medicine: result validity must be demonstrated alongside result generation.

6.3. Recombinant Antigens, Multiplex Serology, and Quantitative Antibody Testing

Dependence on appropriately characterized donor platelets remains a major practical limitation of platelet antibody testing. Platelet panels must contain the antigen combinations required for antibody identification, and low-frequency antigens can be particularly difficult to represent. Recombinant antigen systems offer a potential means of reducing this dependency.
The Recombinantly Expressed Tagged Surface Protein (RETSUP) assay represents an important recent development. Stable HEK293 cell lines were engineered to express defined platelet glycoprotein complexes, including GPIa/IIa, GPIIb/IIIa, GPIb/IX, GPIb/IX/V, and GPV, together with selected HPA-1, HPA-3, and HPA-5 epitopes. Initial evaluation using reference antibodies and clinical samples showed high analytical performance without requiring donor platelets [55].
The potential advantage is substantial: stable antigen sources could improve reproducibility, facilitate investigation of uncommon antigen combinations, and reduce dependence on locally maintained platelet panels. However, recombinant expression does not automatically reproduce every clinically important epitope. Platelet antibodies may recognize structures dependent on glycoprotein folding, membrane organization, post-translational modification, or interactions within larger protein complexes. Wider implementation therefore requires multicenter evaluation across diverse antibody specificities rather than validation with only well-characterized reference antibodies.
Multiplex bead platforms address a different limitation by allowing several platelet antibodies to be investigated simultaneously. Their practical advantages are clear, but comparative data show that MAIPA, PIFT, and multiplex assays detect overlapping rather than identical antibody repertoires [7]. Furthermore, the recent comparison of PAK-LX with dedicated HLA single-antigen bead testing demonstrated that satisfactory performance for platelet-specific antibodies cannot be assumed to imply equivalent performance for HLA antibody screening [30].
Quantitative antibody analysis is another emerging area. A 2026 evaluation of a Luminex-based anti-HPA-1a assay found 97.6% qualitative agreement with quantitative MAIPA and a strong relationship between Luminex MFI and MAIPA-derived antibody concentration in the samples analyzed [56]. These results are promising, particularly because quantitative MAIPA is labor-intensive and available in relatively few laboratories.
However, the experience accumulated with HLA bead assays provides an important warning. Fluorescence intensity is influenced by antigen density, reagent composition, antibody affinity, interference, saturation, and platform-specific properties [12]. Numerical antibody results should therefore not be translated directly into standardized concentrations or clinical risk categories unless those relationships have been independently validated. The goal should be better quantitative comparability, not simply the production of additional numerical outputs.

6.4. Molecular Compatibility, Virtual Crossmatching, and Computational Donor Selection

The clinical value of high-resolution molecular characterization depends on whether the resulting information can be translated into better donor selection. This is particularly relevant in HLA-mediated platelet refractoriness, where conventional antigen matching can severely restrict the compatible donor pool in highly sensitized patients.
Epitope-level compatibility offers one potential solution. A randomized crossover trial demonstrated that HLA epitope-matched platelets were noninferior to conventional HLA antigen-matched platelets for post-transfusion response in alloimmunized refractory patients [39]. Virtual platelet crossmatching, combining recipient antibody specificity with donor HLA information, has also shown feasibility in prospective clinical practice [40].
Recent expert analysis has extended this concept toward functional eplet matching, cumulative donor-specific antibody assessment, molecular compatibility, and the use of multifunctional donor registries [57]. These approaches are attractive because compatibility becomes a ranked molecular relationship rather than a binary search for an HLA-identical donor.
There are, however, important analytical constraints. Different HLA solid-phase assays do not represent identical antigen and eplet repertoires. In a 2025 comparison of four commercial assay configurations, only 82.9% of class I eplets were represented by all four platforms [58]. This does not invalidate epitope-based compatibility, but it demonstrates that computational predictions inherit the limitations of the laboratory data used as input.
The most credible near-term role for computation is therefore structured decision support. Algorithms can integrate antibody specificity, donor genotype, antigen or epitope compatibility, previous transfusion responses, and available inventory to prioritize candidate platelet components. At present, computational donor-selection tools should be regarded as decision-support systems rather than replacements for specialist laboratory interpretation. Any model used for donor ranking should remain transparent enough for the underlying immunologic rationale to be reviewed.

6.5. Standardization, Interoperability, and Demonstration of Clinical Utility

Further increases in analytical sensitivity will have limited value if results remain difficult to reproduce between laboratories. External quality-assessment data in platelet immunology have demonstrated interlaboratory variability in antibody screening and specificity assignment, supporting the need for validated methods, reference materials, and continuing proficiency assessment [14]. Differences in institutional approaches to HLA alloimmunization and platelet refractoriness further illustrate the challenges of translating laboratory findings into consistent clinical practice [18]. Similarly, the 2026 ISTH work on HIT showed that functional platelet activation assays remain affected by differences in donor selection, platelet preparation, heparin concentrations, controls, and interpretation despite decades of clinical use [15,16].
Future development should therefore give greater attention to reference materials, proficiency testing, assay-specific uncertainty, traceable calibration, harmonized reporting terminology, and multicenter reproducibility. Automation may reduce some manual variability, but automation alone does not produce standardization. An automated platform still requires validated controls, clinically appropriate thresholds, and clear interpretation rules.
Information systems represent another underdeveloped component of this field. HLA and HPA genotypes, antibody specificity, donor availability, transfusion history, and post-transfusion platelet responses are often stored in separate systems. Linking these datasets would allow compatibility algorithms to use longitudinal patient information and would make it possible to determine whether increasingly sophisticated matching strategies actually improve transfusion outcomes.
The clinical translation of emerging technologies requires a distinction between analytical validity, clinical validity, and clinical utility. Analytical studies determine whether a method detects or characterizes its intended target accurately and reproducibly. Clinical validation examines whether the resulting information is associated with a relevant diagnostic condition or outcome. Clinical utility requires a further step: evidence that using the information improves clinical decisions, patient management, or outcomes compared with an appropriate alternative strategy.
These distinctions are particularly important in platelet immunology. High concordance between HPA genotyping platforms supports analytical reliability but does not demonstrate improved fetal outcomes or more effective platelet donor selection. Similarly, agreement between antibody assays cannot establish that the measured antibodies are pathogenic. Studies of molecular compatibility address a different question, and their relevance depends on the comparator, patient population, platelet products, and outcomes used to evaluate transfusion efficacy [39,50,51,52,56].
The maturity of a technology should therefore be judged against the clinical question it is intended to resolve. For molecular donor typing, relevant outcomes include the ability to identify suitable components, donor coverage, turnaround time, and operational feasibility. For antibody testing, analytical sensitivity and specificity must be considered alongside diagnostic interpretation and clinically meaningful concordance. For transfusion-selection strategies, platelet count increments are useful intermediate outcomes, but their relationship with bleeding, transfusion requirements, and other patient-centered outcomes requires separate evaluation [2,11,39,46].
Future investigations would benefit from prospective, multicenter designs with clearly specified reference methods, representative clinical populations, predefined analytical thresholds, and clinically relevant comparators. Reporting should distinguish technical feasibility from demonstrated clinical benefit. This distinction will be essential if increasingly complex molecular and computational systems are to move from specialized laboratory applications into routine transfusion practice.
The evidence summarized in Table 6 encompasses studies with different designs, comparators, populations, and endpoints. Analytical concordance studies primarily assess methodological reliability, whereas clinical investigations may evaluate diagnostic performance, post-transfusion platelet recovery, or other patient-related outcomes. For example, the randomized trial of HLA epitope-based platelet selection [39] provides a different level of evidence from observational investigations of virtual compatibility [40] and methodological assessments of HLA epitope representation [57,58]. These findings should therefore be interpreted according to their respective study designs and clinical objectives, without assuming that analytical improvements necessarily translate into better patient outcomes.
Table 6. Emerging technologies and translational priorities in platelet immunology.
Taken together, these developments suggest that the next phase of platelet immunology will be defined less by the ability to generate increasingly large amounts of analytical data than by the ability to identify which data are clinically meaningful. Higher molecular resolution, broader antibody detection, and increasingly sophisticated compatibility algorithms should strengthen, rather than replace, the phenotype-driven approach described throughout this review. The most valuable technologies will therefore be those that demonstrate not only analytical superiority, but also reproducibility, interpretability, and measurable benefit for diagnostic decision-making or transfusion support.

7. Conclusions

Immune-mediated platelet disorders remain diagnostically challenging because no single laboratory method can establish antibody specificity, antigenic relevance, pathogenic potential, and clinical causality in every setting. The most reliable approach is therefore sequential and phenotype-driven, combining serologic testing with molecular typing and, where appropriate, functional assays.
Across these disorders, the laboratory contribution is strongest when serologic, molecular, functional, and clinical evidence are integrated into a coherent immunologic interpretation.
Emerging molecular, recombinant, multiplex, and computational approaches may improve diagnostic resolution and donor selection, but their value will depend on analytical standardization, reproducibility, and demonstration of clinical utility. Increasing analytical sensitivity or molecular resolution should not, by itself, be assumed to improve clinical decision-making.
The role of the specialized platelet immunology laboratory is therefore not simply to detect antibodies, but to integrate serologic, molecular, functional, and clinical information into a defensible immunologic interpretation and, when appropriate, actionable transfusion support.

Author Contributions

Conceptualization, F.P. and L.R.; methodology, F.P., C.T., I.M., O.A. and L.R.; formal analysis, F.P. and L.R.; writing—original draft preparation, F.P. and L.R.; writing—review and editing, F.P., C.T., I.M., O.A. and L.R.; supervision, L.R. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

No new data were created or analyzed in this study. Data sharing is not applicable to this article.

Acknowledgments

During the preparation of this manuscript, the authors used ChatGPT (GPT-5, OpenAI) for language editing, grammatical corrections, and minor image editing. The authors reviewed and verified all modifications and take full responsibility for the final version of the manuscript.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
AABBAssociation for the Advancement of Blood & Biotherapies
ASHAmerican Society of Hematology
CCIcorrected count increment
cfDNAcell-free DNA
cPRAcalculated panel-reactive antibody
ddPCRdroplet digital polymerase chain reaction
DITPdrug-induced immune thrombocytopenia
FNAITfetal and neonatal alloimmune thrombocytopenia
HIPAheparin-induced platelet activation assay
HITheparin-induced thrombocytopenia
HLAhuman leukocyte antigen
HPAhuman platelet antigen
ICTMGInternational Collaboration for Transfusion Medicine Guidelines
ISBTInternational Society of Blood Transfusion
ISTHInternational Society on Thrombosis and Haemostasis
ITPimmune thrombocytopenia
IVIGintravenous immunoglobulin
MAIPAmonoclonal antibody-specific immobilization of platelet antigens
MALDI-TOF MSmatrix-assisted laser desorption/ionization time-of-flight mass spectrometry
MFImean fluorescence intensity
NGSnext-generation sequencing
PCRpolymerase chain reaction
PF4platelet factor 4
PIFTplatelet immunofluorescence test
PTPpost-transfusion purpura
PTRplatelet transfusion refractoriness
RETSUPRecombinantly Expressed Tagged Surface Protein
SABsingle-antigen bead
SRAserotonin release assay
SSCScientific and Standardization Committee
UMI-NGSunique molecular identifier-based next-generation sequencing

References

  1. Sachs, U.J.; Bedei, I.; Wienzek-Lischka, S.; Cooper, N.; Ehrhardt, H.; Axt-Fliedner, R.; Bein, G. Diagnosis and Management of Fetal and Neonatal Alloimmune Thrombocytopenia: An Update 2025. Transfus. Med. Hemother. Off. Organ Der Dtsch. Ges. Fur Transfusionsmedizin Und Immunhamatol. 2025, 52, 318–333. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Panch, S.R.; Vassallo, R.R.; Adams, S.; Borge, D.P.; Gammon, R.; Gandhi, M.J.; Philogene, M.; Sullivan, H.C.; Wu, Y.; Kopko, P. Management of Human Leukocyte Antigen-Mediated Platelet Transfusion Refractoriness: Brief Synopsis and Recent Literature Review. Transfusion 2024, 64, 2380–2390. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Hawkins, J.; Aster, R.H.; Curtis, B.R. Post-Transfusion Purpura: Current Perspectives. J. Blood Med. 2019, 10, 405–415. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Vrbensky, J.R.; Moore, J.E.; Arnold, D.M.; Smith, J.W.; Kelton, J.G.; Nazy, I. The Sensitivity and Specificity of Platelet Autoantibody Testing in Immune Thrombocytopenia: A Systematic Review and Meta-Analysis of a Diagnostic Test. J. Thromb. Haemostasis JTH 2019, 17, 787–794. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Marini, I.; Uzun, G.; Jamal, K.; Bakchoul, T. Treatment of Drug-Induced Immune Thrombocytopenias. Haematologica 2022, 107, 1264–1277. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Cuker, A.; Arepally, G.M.; Chong, B.H.; Cines, D.B.; Greinacher, A.; Gruel, Y.; Linkins, L.A.; Rodner, S.B.; Selleng, S.; Warkentin, T.E.; et al. American Society of Hematology 2018 Guidelines for Management of Venous Thromboembolism: Heparin-Induced Thrombocytopenia. Blood Adv. 2018, 2, 3360–3392. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Costa, T.H.; Bonet-Bub, C.; Kutner, J.M. Platelet Antibody Detection Assays: A Single-Laboratory Comparison of MAIPA, PIFT, and Microsphere-Based Multiplex Assays Pak-Lx. Hematol. Transfus. Cell Ther. 2024, 46, S97–S102. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Sullivan, H.C.; Borge, P.D.J.; Gammon, R.R.; Gandhi, M.; Philogene, M.C.; Wu, Y.; Kopko, P.M. Advances in Human Leukocyte Antigen Testing Technologies and Management Strategies for Platelet Transfusion Refractoriness. Arch. Pathol. Lab. Med. 2025, 149, 372–380. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Porcelijn, L.; Huiskes, E.; de Haas, M. Progress and Development of Platelet Antibody Detection. Transfus. Apher. Sci. Off. J. World Apher. Assoc. Off. J. Eur. Soc. Haemapheresis 2020, 59, 102705. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Provan, D.; Arnold, D.M.; Bussel, J.B.; Chong, B.H.; Cooper, N.; Gernsheimer, T.; Ghanima, W.; Godeau, B.; González-López, T.J.; Grainger, J.; et al. Updated International Consensus Report on the Investigation and Management of Primary Immune Thrombocytopenia. Blood Adv. 2019, 3, 3780–3817. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Nahirniak, S.; Nadarajan, V.; Stanworth, S.J. How I Treat Patients Who Are Refractory to Platelet Transfusions. Blood 2025, 145, 2293–2302. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Sullivan, H.C.; Gebel, H.M.; Bray, R.A. Understanding Solid-Phase HLA Antibody Assays and the Value of MFI. Hum. Immunol. 2017, 78, 471–480. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Arnold, D.M.; Curtis, B.R.; Bakchoul, T. Recommendations for Standardization of Laboratory Testing for Drug-Induced Immune Thrombocytopenia: Communication from the SSC of the ISTH. J. Thromb. Haemostasis JTH 2015, 13, 676–678. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Porcelijn, L.; van Beers, W.; Gratama, J.W.; van’t Veer, M.; De Smet, A.; Sintnicolaas, K. External Quality Assessment of Platelet Serology and Human Platelet Antigen Genotyping: A 10-Year Review. Transfusion 2008, 48, 1699–1706. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Althaus, K.; Bakchoul, T.; Gruel, Y.; Nazy, I.; Pouplard, C. Standardization of Platelet Activation Tests for the Diagnosis of Heparin-Induced Thrombocytopenia: Communication from the ISTH-SSC Subcommittee on Immune-Mediated Platelet Disorders. J. Thromb. Haemostasis JTH 2026, 24, 3333–3342. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Althaus, K.; Nazy, I.; Bakchoul, T.; Pouplard, C. Survey Report on Functional Tests in Heparin-Induced Thrombocytopenia: Communication from the ISTH SSC Subcommittee on Immune-Mediated Platelet Disorders. J. Thromb. Haemostasis JTH 2026, 24, 3343–3348. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Pothof, R.; van den Akker-van Marle, E.M.; de Vos, T.W.; Tiller, H.; Bussel, J.B.; Ahlén, M.T.; Curtis, B.R.; Lopriore, E.; Verweij, E.J.T.J.; de Haas, M. Rising to the Challenge: An International Delphi Consensus Study on Fetal and Neonatal Alloimmune Thrombocytopenia. Lancet Haematol. 2025, 12, e304–e311. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Baykara, Y.; Fang, D.C.; Tran, M.-H.; Yunce, M. Practice Variability in the Evaluation and Management of HLA Alloimmunization in Platelet Refractoriness: A Multi-Institutional Survey in the USA. Transfus. Clin. Et Biol. J. De La Soc. Fr. De Transfus. Sang. 2026, 33, 79–83. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Cantisani, R.; Del Re, V.; Toraldo, F.; Cantara, S.; Pozzessere, S.; Marotta, G.; Spreafico, A. HLA Class I Expression on Human Platelets Is Highly Variable and Correlates with Distinct Allele Group Frequencies. Blood Transfus. (Trasfus. Del Sangue) 2024, 22, 440–449. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Cabral, L.J.B.; Lopes, D.P.; dos Santos Martins Filho, E.; Valois, R.C.; Oliveira, P.C.A.J.; de Souza Mendonça-Mattos, P.J. Anti-HLA Antibody Formation Increases the Chances of Platelet Refractoriness in Platelet-Transfused Patients: A Systematic Review with Meta-Analysis. Hematol. Transfus. Cell Ther. 2025, 47, 103821. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Curtis, B.R.; McFarland, J.G. Human Platelet Antigens-2013. Vox Sang. 2014, 106, 93–102. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Hayashi, T.; Hirayama, F. Advances in Alloimmune Thrombocytopenia: Perspectives on Current Concepts of Human Platelet Antigens, Antibody Detection Strategies, and Genotyping. Blood Transfus. (Trasfus. Del Sangue) 2015, 13, 380–390. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Veldhuisen, B.; Porcelijn, L.; Ellen van der Schoot, C.; de Haas, M. Molecular Typing of Human Platelet and Neutrophil Antigens (HPA and HNA). Transfus. Apher. Sci. Off. J. World Apher. Assoc. Off. J. Eur. Soc. Haemapheresis 2014, 50, 189–199. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. Valentin, A.; Windhorst, A.C.; Sachs, U.J.; Wienzek-Lischka, S.; Bedei, I.; Wolter, A.; Axt-Fliedner, R. Noninvasive Fetal HPA Genotyping for FNAIT: Diagnostic Accuracy and Technical Performance of Molecular Methods. Transfus. Med. Rev. 2026, 40, 151017. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Bertrand, G.; Levallois, O.; Santesteban, C.G.; Nogues, N.; Renac, V. Non-Invasive Fetal HPA Genotyping by UMI-NGS: A Robust Method for Antenatal Diagnosis Including 48 Fetal DNA Markers. Blood Transfus. (Trasfus. Del Sangue) 2026, 24, 7–18. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. Couvidou, A.; Rojas-Jiménez, G.; Dupuis, A.; Maître, B. Anti-HLA Class I Alloantibodies in Platelet Transfusion Refractoriness: From Mechanisms and Determinants to Therapeutic Prospects. Front. Immunol. 2023, 14, 1125367. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. Arnold, D.M.; Kukaswadia, S.; Nazi, I.; Esmail, A.; Dewar, L.; Smith, J.W.; Warkentin, T.E.; Kelton, J.G. A Systematic Evaluation of Laboratory Testing for Drug-Induced Immune Thrombocytopenia. J. Thromb. Haemostasis JTH 2013, 11, 169–176. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Kiefel, V. The MAIPA Assay and Its Applications in Immunohaematology. Transfus. Med. 1992, 2, 181–188. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Arnold, D.M.; Nazi, I.; Warkentin, T.E.; Smith, J.W.; Toltl, L.J.; George, J.N.; Kelton, J.G. Approach to the Diagnosis and Management of Drug-Induced Immune Thrombocytopenia. Transfus. Med. Rev. 2013, 27, 137–145. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Enten, H.; Liacini, A.; Janes, D.; Stedem, R.; Gaule, L.; Berka, N. Assessing the Reliability of the PAK-LX HLA Class I Bead in Platelet Transfusion Compatibility Testing. Hum. Immunol. 2026, 87, 111711. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  31. Al-Samkari, H.; Rosovsky, R.P.; Karp Leaf, R.S.; Smith, D.B.; Goodarzi, K.; Fogerty, A.E.; Sykes, D.B.; Kuter, D.J. A Modern Reassessment of Glycoprotein-Specific Direct Platelet Autoantibody Testing in Immune Thrombocytopenia. Blood Adv. 2020, 4, 9–18. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Bissola, A.-L.; Zhang, Y.; Cranstone, M.; Moore, J.C.; Warkentin, T.E.; Arnold, D.M.; Nazy, I. Evaluating Diagnostic Algorithms for Heparin-Induced Thrombocytopenia Using Two Combined Automated Rapid Immunoassays. Semin. Thromb. Hemost. 2024, 50, 1123–1130. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Aster, R.H.; Curtis, B.R.; McFarland, J.G.; Bougie, D.W. Drug-Induced Immune Thrombocytopenia: Pathogenesis, Diagnosis, and Management. J. Thromb. Haemostasis JTH 2009, 7, 911–918. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Arachchillage, D.J.; Thachil, J.; Anderson, J.A.M.; Baker, P.; Poles, A.; Kitchen, S.; Laffan, M. Diagnosis and Management of Heparin-Induced Thrombocytopenia: Third Edition. Br. J. Haematol. 2024, 204, 459–475. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Glover, R.; Yeboah, B.; Vassallo, R.R.; Stolla, M.; Panch, S.R.; Khan, J.; Kogler, V.J.; Luckey, C.J.; Gorham, J.D. It Is Time to Eliminate the One-hour Corrected Count Increment in the Diagnostic Workup of Platelet Transfusion Refractoriness. Transfusion 2025, 65, 1553–1555. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Jackman, R.P.; Deng, X.; Bolgiano, D.; Lebedeva, M.; Heitman, J.W.; Busch, M.P.; Slichter, S.J.; Norris, P.J. Low-Level HLA Antibodies Do Not Predict Platelet Transfusion Failure in TRAP Study Participants. Blood 2013, 121, 3261–3266. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Petz, L.D.; Garratty, G.; Calhoun, L.; Clark, B.D.; Terasaki, P.I.; Gresens, C.; Gornbein, J.A.; Landaw, E.M.; Smith, R.; Cecka, J.M. Selecting Donors of Platelets for Refractory Patients on the Basis of HLA Antibody Specificity. Transfusion 2000, 40, 1446–1456. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Rioux-Massé, B.; Cohn, C.; Lindgren, B.; Pulkrabek, S.; McCullough, J. Utilization of Cross-Matched or HLA-Matched Platelets for Patients Refractory to Platelet Transfusion. Transfusion 2014, 54, 3080–3087. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Marsh, J.C.; Stanworth, S.J.; Pankhurst, L.A.; Kallon, D.; Gilbertson, A.Z.; Pigden, C.; Deary, A.J.; Mora, A.S.; Brown, J.; Laing, E.S.; et al. An Epitope-Based Approach of HLA-Matched Platelets for Transfusion: A Noninferiority Crossover Randomized Trial. Blood 2021, 137, 310–322. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  40. Bonet-Bub, C.; Blanco, B.P.; de Oliveira, T.C.; Sampaio, T.B.; Gomes, I.; de Freitas Dutra, V.; Costa, T.H.; Kutner, J.M. Virtual Platelet Cross-Matching as Transfusion Management for Patients with Immune Platelet Refractoriness. Vox Sang. 2024, 119, 272–276. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  41. Bussel, J.B.; Hirshman, J.M.; Kapur, R. Anti-HPA-1a Fetal-Neonatal Alloimmune Thrombocytopenia: Reframing Diagnostics, Pathophysiology, and Management. Blood 2026, 147, 3144–3167. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  42. Lieberman, L.; Greinacher, A.; Murphy, M.F.; Bussel, J.; Bakchoul, T.; Corke, S.; Kjaer, M.; Kjeldsen-Kragh, J.; Bertrand, G.; Oepkes, D.; et al. Fetal and Neonatal Alloimmune Thrombocytopenia: Recommendations for Evidence-Based Practice, an International Approach. Br. J. Haematol. 2019, 185, 549–562. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  43. Aggarwal, A.; Prodger, C.; Hockley, B.; Thomas, W.; Murphy, M.F.; Lieberman, L.; Bussel, J.B.; Vlachodimitropoulou, E.; Desborough, M.J.R. Fetal and Neonatal Alloimmune Thrombocytopenia (FNAIT): Survey of UK Fetal Medicine Centres on Antenatal Management of Subsequent Affected Pregnancies. Br. J. Haematol. 2026, 209, 240–247. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  44. Liu, X.; Hu, Y.; Hou, M. Synopsis of the 2025 Guideline for the Diagnosis and Management of Adult Primary Immune Thrombocytopenia. Chin. Med. J. 2026, 139, 2063–2065. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  45. Metcalf, R.A.; Nahirniak, S.; Guyatt, G.; Bathla, A.; White, S.K.; Al-Riyami, A.Z.; Jug, R.C.; La Rocca, U.; Callum, J.L.; Cohn, C.S.; et al. Platelet Transfusion: 2025 AABB and ICTMG International Clinical Practice Guidelines. JAMA 2025, 334, 606–617. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  46. Reda, S.; Rühl, H. Diagnosis and Management of Immune Platelet Transfusion Refractoriness. Hamostaseologie 2026. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  47. de Vos, T.W.; Winkelhorst, D.; Árnadóttir, V.; van der Bom, J.G.; Canals Surís, C.; Caram-Deelder, C.; Deschmann, E.; Haysom, H.E.; Hverven, H.B.C.; Lozar Krivec, J.; et al. Postnatal Treatment for Children with Fetal and Neonatal Alloimmune Thrombocytopenia: A Multicentre, Retrospective, Cohort Study. Lancet Haematol. 2022, 9, e844–e853. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  48. Chowdhury, S.R.; Sirotich, E.; Guyatt, G.; Modi, D.; Cuker, A.; Breakey, V.R.; Grace, R.F.; Pai, M.; Beck, C.E.; Yan, J.W.; et al. Guideline on the Emergency Management of Critical Bleeding in Patients with Immune Thrombocytopenia. Blood Adv. 2026, 10, 5558–5575. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  49. Cuker, A.; Terrell, D.R.; Sowdagar, H.; Arnold, D.M.; Audia, S.; Bussel, J.B.; Gonzalez-Lopez, T.J.; Grace, R.F.; Masias, C.; McCrae, K.R.; et al. American Society of Hematology 2026 Guidelines for Immune Thrombocytopenia (ITP): Initial and Second-Line Therapy in Adults with Primary ITP. Blood Adv. 2026, 10, 7076–7097. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  50. Guglielmino, J.; Jackson, D.E. Next Generation Sequencing of Human Platelet Antigens for Routine Clinical Investigations and Donor Screening. Transfus. Med. Rev. 2022, 36, 87–96. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  51. He, Y.; Wang, F.; Wu, Z.; Zhang, W.; Zhu, F. Establishment and Application of a Multiplex PCR NGS Method for the Genotyping of HLA-Class I and HPA. HLA 2024, 104, e15716. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  52. Zhao, P.; Lyu, Q.; Xu, Y.; Liang, Y.; Wu, Y.; Li, Q.; Wang, H.; Yuan, Y.; He, R.; Fu, W.; et al. A Novel Approach to Simultaneous Genotyping of Human Platelet Antigen Systems and Human Leucocyte Antigen Class I Loci Using PacBio Long-Read Sequencing. Vox Sang. 2025, 120, 63–70. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  53. Zhu, H.; Li, R.; Fu, M.; Yang, Q.; Ma, Q.; Lu, P.; Zhu, Z.; Ye, L. Development of Mass Spectrometry-Based Genotyping Method for Simultaneous Detection of 35 HPA Systems, 5 HNA Systems and the CD36 Antigen. Transfusion 2026, 66, 998–1011. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  54. Sun, H.; Su, Q.; Zeng, J.; Xu, Y.; Chang, L.; Yan, Y.; Ma, J.; Ji, H.; Wang, L. Rapid and Robust Multiplex Multicolour Melting Curve Analysis Enables Simultaneous Detection of HLA Cross-Reactive Groups and HPA Genotypes. HLA 2026, 107, e70626. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  55. Weber, S.; Arnold, J.B.Z.; Sachs, U.J.; Luppa, P.B. Recombinantly Expressed Tagged SUrface Protein (RETSUP) Assay: A New Diagnostic System for the Detection of Antibodies to Platelets. J. Thromb. Haemostasis JTH 2024, 22, 1187–1201. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  56. Asplund Högelin, K.; Deschmann, E.; Höglund, P.; Wikman, A. Rapid Anti-HPA-1a Antibody Quantification with a Luminex Bead-Based Assay: A Method Evaluation. Vox Sang. 2026, 121, 345–351. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  57. Yu, N.; Panch, S.; Mepani, K.; Stanworth, S.; Bonet-Bub, C.; Gragert, L.; Menard, V.; Mangiola, M.; Maiers, M.; Berka, N. “Epitope-Based Matching for Platelet Transfusion Overview: Is It Time?”-Insights and Future Directions from the 2024 American Red Cross Symposium on Platelet Component Selection. Transfusion 2025, 65, 1954–1965. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  58. Hernandez, P.V.; Shen, M.; Tang, M.S.; Taniguchi, M.; Borcherding, N.; Liu, C. Antigen and Eplet Coverage by Representative Solid-Phase Immunoassays for Anti-HLA Antibody Screen. Hum. Immunol. 2025, 86, 111339. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.