Abstract
Deep high-temperature excavation faces suffer severe heat and moisture hazards, but coupled transport in surrounding rock and the influence of ventilation and rock properties remain unclear. A coupled heat–moisture–airflow transport model considering moisture diffusion in the surrounding rock was established, and a three-dimensional numerical model was built. The model explicitly resolves the airflow field, the temperature field and the moisture field; stress effects are discussed as a stress-dependent extension rather than a fully solved mechanical field. Sensitivity analysis and response surface methodology were applied. Results show that the air duct jet creates a nonuniform flow that controls temperature and humidity zoning. Near the inlet, temperature drops by more than 20 °C within 1 to 5 days, and after 50 days most of the roadway falls below 35 °C. Relative humidity near the heading face decreases from 0.7 to below 0.6 and later recovers to 0.62 to 0.65. When thermal conductivity increases from 1 to 4 W m−1 K−1, the low temperature zone shrinks sharply. When the moisture transport coefficient decreases from 10−5 to 10−7 m2/s, relative humidity drops significantly. Response surface analysis shows that initial rock temperature has the greatest influence on average temperature, and the interaction between equipment heat dissipation and spray humidification also has a clear influence. These findings clarify coupled heat and moisture transport in surrounding rock and support heat hazard prediction, ventilation cooling, and humidity control in deep mines.