Abstract
The construction of extradosed bridges requires accurate determination of concrete mechanical properties for updating technological designs and Finite Element (FE) models. This article presents the results of concrete specimen testing and full-scale load tests used to update the technological project, computational models, and prestressing design of an extradosed bridge in Kostrzyn, Poland. Concrete properties were determined using the direct method and standard-based method A. The updated FE models achieved an average accuracy of 96% in flexural and torsional stiffness. The paper also proposes a methodology for developing a digital twin based on load test results and FE model updating.
1. Introduction
The construction of extradosed bridges represents one of the major challenges in bridge engineering, both from the design and construction perspectives. It requires knowledge of the mechanical properties of concrete, determined on the basis of an approved concrete mix design. Accurate determination of the compressive strength and modulus of elasticity id essential for updating the construction methodology and finite element (FE) numerical models.
The material tests presented in this article were carried out on the extradosed bridge in Kostrzyn, Poland. The research includes analyses of a trial concrete mix, enabling verification of the parameters assumed in the original mix design, as well as testing of core samples extracted from selected locations of the completed structure. Determination of key material properties, including compressive strength and modulus of elasticity, enabled the designer to correctly update the prestressing scheme. The obtained results also served as input data for the calibration of the FEM numerical model. Consequently, a model with parameters closely reflecting the actual structure was developed, and its accuracy was verified through static and dynamic load testing.
The bridge was additionally equipped with a Structural Health Monitoring (SHM) system, whose data, together with the results of laboratory tests, form the basis for the development of a digital twin. It is a virtual representation of the physical structure, in which load-testing results constitute fundamental element for determining the structural response. Such information is essential for accurately reproducing the behavior of the bridge, enabling the identification of stiffness and dynamic properties, which are key parameters of the updated FEM model, forming part of the digital twin.
The aim of this paper is to define the role of material investigations and load-testing in the process of updating numerical models. Their significance using the example of an extradosed bridge, illustrating the comprehensive integration of information obtained from material testing, the SHM system, and load-testing.
2. Bridge Description
The new bridge carrying National Road No. 31 is a three-span continuous extradosed structure with a prestressed concrete box girder made of C60/75 concrete. The theoretical span lengths are 75.0 + 150.0 + 75.0 m, giving a total bridge length of 300 m. The total width of the structure varies from 17.28 m within the spans to 19.28 m above the intermediate supports. The bridge carries an 8.00 m wide two-way carriageway and 2.50 m wide pedestrian and bicycle paths on both sides (Figure 1).
Figure 1.
Side view of the bridge.
The superstructure consists of a single-cell box girder with a variable structural height ranging from 3.20 m at the abutments and within the spans to 4.80 m above the intermediate supports. At the locations of the piers, 17.0 m high pylons with a cross-section of 1.75 × 2.50 m were constructed and monolithically connected to the box girder. The superstructure is supported on the piers and abutments through lenticular bearings. The abutments were designed as massive structures, while the intermediate supports were designed as piers connected by a diaphragm. The supports were founded on precast piles (Figure 2).
Figure 2.
Cross-section in the span.
3. Concrete Testing
The objective of the concrete testing program was to determine the development of its mechanical properties for the purpose of updating the prestressing scheme, taking into account the stages of bridge construction. To determine the compressive strength and modulus of elasticity, trial batches of the concrete mix were prepared based on two mix design variants. In addition, the properties of the concrete were determined using core samples extracted from designated locations within the sections of spans No. 1 and 3 [1].
The modulus of elasticity assumed in the design for C60/75 concrete was 39.0 GPa. Both the PN-EN standards and the Model Code emphasize that the modulus of elasticity strongly depends on the composition of the concrete, particularly on the type of aggregate used. The tabulated values of the modulus of elasticity refer to concrete made with quartzite aggregate. No guidelines are available for modifying the modulus of elasticity for aggregate types commonly used in Poland. The mechanical properties of the concrete were determined on the basis of destructive testing of specimens cured under standardized conditions [2,3,4,5,6], as well as on core samples extracted from the structure [7,8]. This approach made it possible to determine the mechanical properties of both the in-situ and the concrete produced according to the modified mix design adopted during construction.
The analysis of the mechanical properties of the concrete was carried out using the direct method [9] and Method A [6] (Figure 3 and Figure 4). The direct method (author-defined terminology) for determining the secant modulus of elasticity of concrete complies with the requirements of the relevant standard [9]. The obtained values of Ecm,1 correspond to the construction stage prior to the elimination of the initial irreversible deformations of the structure. Accordingly, the value of Ecm,1 is recommended by the authors for updating the prestressing scheme and the prescribed construction camber, depending on the adopted construction technology (Table 1).
Figure 3.
Graphical comparison of the determination of the modulus of elasticity of concrete using the direct method and method A.
Figure 4.
Research implementation.
Table 1.
Summary of mechanical properties of concrete determined by the direct method.
In Method A, the initial modulus Ec,0 and the stabilized modulus Ec,s were determined in accordance with the procedure specified in the standard [6] and the loading process applied to the specimens. After the occurrence of the initial irreversible deformations, a prestressed bridge structure subjected to the full prestressing force behaves within the linear-elastic range. The resulting value of Ecm,2 corresponds to the stabilized modulus and is recommended by the authors for updating structural analyses of the bridge after the introduction of the prestressing force (Table 2).
Table 2.
Summary of mechanical properties of concrete determined by method A.
For the analysis of the mechanical properties of the concrete, 12 cylindrical specimens with a diameter of 150 mm and a height of 300 mm were prepared. Destructive tests to determine the stress–strain relationship were carried out after 6 and 28 days of curing. In accordance with the adopted testing methodology, the mechanical properties of concrete cured under standardized conditions were determined without considering thermal effects. In addition, 18 core specimens with a length to diameter ratio of 2:1 (L ≈ 180 mm and D = 79 mm) were extracted from six selected locations within the structure. Three core specimens were taken from each location. In phase II they were located horizontally in the webs, while in phases III and Vb vertically in the upper plate and in phase IV also vertically in the lower plate (Figure 5).
Figure 5.
Research implementation.
Based on the tests conducted on specimens stored under standardized curing conditions, it can be concluded that the analyzed concrete is characterized by a moderately high strength gain. After 6 days, a concrete compressive strength of 60.8 MPa (101%) was achieved. Compressive strength tests at 28 days demonstrate an increase in strength value up to 74.6 MPa (124%). The average bulk density of all tested specimens was 2393 kg/m3. For the purpose of making decisions during construction regarding the early prestressing of the structure, it was recommended to adopt the compressive strength test results obtained from specimens cured under standardized conditions.
Deformability tests of the concrete confirmed that the modulus of elasticity value determined via the direct method was close to the standard value according to PN-EN, utilizing the multiplier αE = 1.00, as for aggregate with a moderate modulus. Considering the technological processes associated with mixture placement, the timing of prestressing, and the operational phase, two modulus values adopted for design calculations should be distinguished. For the purpose of updating the camber determination and the prestressing program, it was recommended to adopt the modulus value determined by the direct method without eliminating permanent deformations. Considering the timing of prestressing at 6 days after concreting, the value is Ecm,1 = 30.0 GPa. For the purpose of updating structural analyses in the operational phase, it was recommended to adopt the concrete modulus of elasticity determined by Method A, with a value of Ecm,2 = 42.2 GPa.
Supplementary tests of the mechanical properties of the concrete placed prior to the mix design correction aimed to confirm the concrete class while determining the modulus of elasticity. The correlation between core strength and standard strength was performed considering the specimen dimensions corresponding to the cylindrical strength, incorporating a correction factor of 0.85. The average compressive strength for all specimens was 76.3 MPa. The average concrete modulus of elasticity determined via the direct method for all specimens was 34.5 GPa. The average bulk density of all tested specimens was 2294 kg/m3 and was lower by 99 kg/m3 (4%) compared to the trial mix. The tests confirmed that the placed concrete met the required mechanical properties for the C60/75 design class.
4. Load Testing
The objective of the load testing was to validate the FEM (Finite Element Method) model for the purpose of developing a digital twin. In addition to the installed structural health monitoring system, this approach can enable the asset manager to effectively maintain the structure during its operational phase. The static testing program incorporated three span configurations (S1 ÷ S3), selected based on the condition of maximum span loading, two support configurations (P1, P2), selected based on the condition of maximum cross-sectional loading over the intermediate supports, and one asymmetrical span configuration (N1) aimed at verifying the transverse interaction of the structure (Figure 6). Due to traffic management within the approach zone, the dynamic testing program allowed for two-way passages at speeds up to 30 km/h. The investigations utilized eight 5-axle trucks with a gross vehicle weight of approximately 40.0 t and two 4-axle trucks with a gross vehicle weight of approximately 32.0 t. Mechanical sensors and precision levelling were employed to measure displacements and deflections under the static load, in compliance with the PB-01 testing procedure of the quality management system (Figure 7).
Figure 6.
Implemented load configurations.
Figure 7.
Layout and designation of measurement points.
A spatial beam-shell model of class (e1 + 2; p3) was adopted for structural calculations. The assumed geometric parameters of the longitudinal beams, deck slab strips, cross-girders, pylons, and stay cables were represented by beam elements. The geometric characteristics of the elements were defined in accordance with their actual geometry. The torsional moment values were calculated for the entire box cross-section (treated as a closed section) and distributed between the individual webs A and B. Transverse beams representing the stiffness of the slab strip between the webs were replaced by a single cross-section with a bending stiffness equal to the sum of the bending stiffness of the upper and lower slabs within the given section. The cross-section of the stay cables was reduced to a circular section with a diameter derived from the total cross-sectional area of the strands. Additionally, for the purpose of generating the applied load, a shell element with negligible stiffness was implemented, featuring a finite element mesh conforming to the bridge deck geometry. The modulus of elasticity of the C60/75 concrete superstructure was adopted based on the concrete deformability tests described above, amounting to Ecm,2 = 42.2 GPa [2], whereas the modulus of elasticity of the stay cable prestressing steel was assumed to be Es = 170.0 GPa (Figure 8).
Figure 8.
Visualization of the computational model.
Based on the measurements, the vertical displacements of the box girder webs were calculated at the designated locations. The recorded values served to determine the maximum total, permanent, and elastic deflections at the investigated points within the loaded spans. These magnitudes, which are essential for verifying the proper structural behavior of the load-bearing system, are presented below. The elastic deflections of the superstructure were close to the theoretically calculated values, ranging from 89% to 101% of their magnitude. On average, the elastic deflections of the analyzed spans accounted for approximately 96% of the design values. These results demonstrate consistent span stiffness and, consequently, the correct load-bearing capacity as theoretically assumed. The permanent deflections ranged from 0% to 10% of the total deflections, thus satisfying the standard requirement of not exceeding the 10% threshold (Table 3).
Table 3.
Maximum deflections of the box girder web in the implemented load configurations [mm].
As part of the load testing, the implemented load configurations served to evaluate the torsional stiffness of the girder. The results, in the form of instantaneous deflections of the two girder webs, are summarized below, where they are also compared with the deflections calculated using the adopted model. The obtained results indicate the correct transverse behavior of the superstructure and its high correlation with the computational results. The torsional stiffness, defined here as the percentage of the deflections at individual points relative to their total deflections, demonstrates that the torsional stiffness of the spans is consistent with that obtained from the model (Table 4).
Table 4.
Evaluation of the torsional stiffness of the box girder [mm].
The dynamic testing of the structure was conducted following the static load testing. The results, in the form of time histories of vertical displacements during the test runs, were recorded electronically. The measurement setup consisted of a laptop, a Siemens LMS SCADAS multichannel data acquisition system, a Peltron linear inductive displacement sensor, and PCB Piezotronics piezoelectric accelerometers. A sampling frequency of 256 Hz was applied during the measurements.
The dynamic amplification factor (DAF) of the span during the test run at a speed of 30 km/h reached a maximum value below 1.00. The lowest identified natural frequency of vertical vibrations of the deck was 2.01 Hz, which was slightly higher than the theoretically calculated value of 1.82 Hz. The logarithmic decrement of damping exhibited a typical, moderate value ranging from 0.0258 to 0.0907. No tendency for beating phenomena was observed during the testing. Visual inspection of the structure after the tests, particularly following the runs over a bump, did not reveal any anomalies (Figure 9).
Figure 9.
Visualization of the computational model.
5. Conclusions
The investigations of the mechanical properties of concrete conducted during the construction phase determined the modulus of elasticity values both before and after the occurrence of permanent deformations. Based on these findings, the FEM model used by the designer during construction, as well as an independent model utilized in the proof load testing process, were updated. The acceptance tests allowed for the verification of the applied computational models, yielding high consistency in terms of bending and torsional stiffness, which reached an average level of 96%. This confirms the validity of the assumptions of the presented method and its usefulness in the analysis of concrete bridges that are particularly sensitive to deviations in the modulus of elasticity.
Identifying the actual material characteristics of the structure, its stiffness, and its behavior under load is also essential when developing a digital twin system for a bridge structure. Its concept is rooted in creating a virtual replica of the physical structure that is as faithful as possible, incorporating a range of simulation, analytical, and visualization modules that enable continuous monitoring of the current structural health. A component of the digital twin can include, among others, a BIM model, which serves as a database of the asset history and an interface providing access to key information and tools. Alongside it, an FEM model can function simultaneously to perform ongoing computational analyses aimed at verifying the actual structural response measured by the monitoring system, including its reaction to environmental or operational actions. Discrepancies between the actual and simulated responses can indicate structural degradation or damage, which are then reported and visualized in dedicated system modules. This type of analysis requires the implementation of advanced predictive and classification algorithms, often embedded within FEM models, which—without verification and updating based on material testing and proof load testing—might fail to accurately reflect the actual condition and behavior of the structure (Figure 10).
Figure 10.
Material testing and load testing in the digital twin development process.
Author Contributions
Conceptualization P.Ł., M.J., D.P. and M.U.; methodology P.Ł., M.J., D.P. and M.U.; validation P.Ł. and K.B.; formal analysis P.Ł., M.J., D.P., M.U., K.B. and G.P.; investigation P.Ł., M.J., D.P. and M.U.; resources P.Ł.; data curation P.Ł., M.J., D.P., M.U. and K.B.; writing – original draft preparation P.Ł., M.J., D.P., M.U., K.B. and G.P.; writing – review and editing D.P. and K.B.; visualization P.Ł. and M.J.; supervision P.Ł. and M.J.; project administration P.Ł. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
Dataset available on request from the authors.
Conflicts of Interest
The authors declare no conflict of interest.
References
- Sprawozdanie z Badań Określających Cechy Mechaniczne Betonu w Ramach Budowy Mostu Drogowego w km 107,211 DK31 Przez Rzekę Wartę w Kostrzynie nad Odrą; Mosty PL: Rybnik, Poland, 2025.
- PN-EN 206+A1:2016-12; Beton: Wymagania, Właściwości, Produkcja i Zgodność. Polski Komitet Normalizacyjny PKN: Warszawa, Poland, 2016.
- PN-EN 12350-1:2019; Badania Mieszanki Betonowej. Część 1: Pobieranie Próbek I Uniwersalna Aparatura. Polski Komitet Normalizacyjny PKN: Warszawa, Poland, 2019.
- PN-EN 12390-2:2019; Badanie Betonu. Część 2. Wykonywanie i Pielęgnacja Próbek do Badań Wytrzymałości. Polski Komitet Normalizacyjny PKN: Warszawa, Poland, 2019.
- PN-EN 12390-3:2019; Badanie Betonu. Część 3. Wytrzymałość na Ściskanie Próbek do Badania. Polski Komitet Normalizacyjny PKN: Warszawa, Poland, 2019.
- PN-EN 12390-13:2021-12; Badania Betonu. Część 13: Wyznaczanie Siecznego Modułu Sprężystości Przy Ściskaniu. Polski Komitet Normalizacyjny PKN: Warszawa, Poland, 2021.
- PN-EN 12504-1:2019; Badania Betonu w konstrukcjach Część 1: Próbki Rdzeniowe. Pobieranie, Ocena i Badania Wytrzymałości na Ściskanie. Polski Komitet Normalizacyjny PKN: Warszawa, Poland, 2019.
- PN-EN 13791:2019; Ocena Wytrzymałości Betonu na Ściskanie w Konstrukcjach i Prefabrykowanych Wyrobach Betonowych. Polski Komitet Normalizacyjny PKN: Warszawa, Poland, 2019.
- PN-EN 1992-2:2010; Eurokod 2: Projektowanie Konstrukcji z Betonu. Część 2: Mosty z Betonu. Obliczanie i Reguły Konstrukcyjne. Polski Komitet Normalizacyjny PKN: Warszawa, Poland, 2010.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.