Abstract

This study presents a displacement feasibility methodology for a closed-center load-sensing hydraulic system intended for industrial forklift applications. The approach combines analytical hydraulic calculations with simulation-based verification in Automation Studio. A Perkins D3900K diesel engine (Bulgarian industrial group Balkancar) and several Danfoss H1 axial piston pump (Danfoss Power Solutions Nordborg, Denmark) displacements were evaluated under engine power limitations. Pump flow, torque demand, hydraulic power, and a power-limited pressure envelope were derived to support engine–pump matching. The results show that oversized pumps significantly reduce allowable pressure, particularly at higher engine speeds. Pump displacements of 45–60 cm3/rev provide the most balanced compromise between pressure capability and practical flow delivery.

1. Introduction

Hydraulic systems in industrial forklifts must provide reliable and controllable motion for load-handling functions such as lifting, tilting, and lateral displacement. These functions require stable pressure generation, sufficient flow delivery, and acceptable dynamic response under variable loading conditions. In practice, the hydraulic power unit must also support simultaneous actuation (e.g., lifting while tilting), which increases the demand for efficient flow distribution and pressure control [1].
Hydraulic circuits are commonly grouped into open- and closed-type architectures. In open systems, the pump draws fluid from a tank and returns it to the reservoir after performing work. Pressure is typically limited by a relief valve, and the pump often operates at a constant displacement, which can lead to unnecessary throttling losses at partial load. Closed systems circulate fluid primarily between the pump and actuator in a loop, frequently using variable-displacement pumps with compensator mechanisms to control pressure and flow. While closed and pressure-compensated solutions can reduce throttling losses, they may introduce increased system cost and additional heat generation when operating away from the optimum working point [1].
Load-sensing (LS) systems represent an advanced approach aimed at improving energy efficiency by adapting pump output to the instantaneous load demand. A closed-center LS system maintains near-zero flow at standby and raises the supply pressure only to the level required by the highest load in the system, typically with a defined pressure margin for control stability. The core element is a variable-displacement axial piston pump controlled by a differential-pressure compensator and a load-sensing signal generated by the directional control valves. This architecture reduces standby losses compared to conventional pressure-compensated systems and improves overall efficiency under variable duty cycles [1,2,3,4,5,6].
Despite the advantages of LS technology, the preliminary sizing of forklift hydraulic systems is often performed using simplified flow-based criteria, focusing mainly on the required actuator speed. In engine-driven mobile machinery, this approach can be misleading because pump displacement selection directly affects both flow capacity and the maximum achievable pressure under limited engine power. Oversizing the pump increases flow and power demand, which can force the system into persistent power-limited operation, reduce pressure capability at higher speeds, and deteriorate efficiency through increased throttling and heat generation [2].
However, the available literature mainly discusses load-sensing hydraulic architectures, component behavior, or general energy-efficiency aspects, while less attention is given to the preliminary displacement feasibility of axial piston pumps under finite engine power in forklift-specific applications. In particular, the combined influence of pump displacement, engine speed, available engine power, and required hydraulic pressure is rarely presented as a practical selection envelope for early-stage design. This creates a design gap between theoretical pump sizing and the actual power-limited operation of engine-driven mobile machinery.
This study addresses this practical design gap by integrating engine power constraints into the displacement feasibility assessment of a closed-center load-sensing hydraulic system for an industrial forklift. A Perkins D3900K diesel engine is considered as the prime mover, and a range of Danfoss H1 axial piston pump displacements is evaluated using a combined analytical and simulation-based approach [7]. The hydraulic system architecture is defined as shown in Figure 1, while the lifting simulation model and measured variables are illustrated in Figure 2. The engine torque and power characteristics used for the feasibility analysis are provided in Figure 3. The main contribution of this work is the derivation and application of a power-limited pressure envelope to support displacement selection, enabling a quantitative engine–pump matching procedure suitable for preliminary design and dynamic modeling stages.
Figure 1. Functional structure of a closed-center load-sensing hydraulic system: 1—internal combustion engine section; 2—axial piston pump section; 3—external gear charge pump; 4—section with non-return valves and variable throttle valves; 5—telescopic lifting cylinders; 6—tilting cylinders; 7—lateral displacement cylinder; 8—emergency lowering section; 9—manometer; 10—accumulator; 11—four – way fitting; 12—4/3 directional valve section; 13—hydraulic directional valve; 14—relief valve; 15—filter; 16—tank; 17—one-way valve 18—hydraulic lines.
Figure 2. Functional block diagram of the closed-center load-sensing hydraulic system with the main pump, charge pump, directional valve, safety valves, actuator lines, throttle/check valve assembly, and emergency lowering subsystem.
Figure 3. External speed characteristic of the Perkins D3900K diesel engine used in the forklift application: (a) engine torque curve; (b) corresponding power output as a function of rotational speed.
In the following sections, the governing equations for pump flow, torque, and power limitation are presented, the simulation model is described, and the displacement-dependent feasibility results are discussed based on the derived pressure envelope and flow characteristics. The approach can be further optimized, as discussed in related experimental and system integration studies [8,9].
The different curves in Figure 3 represent the engine torque and power characteristics, respectively. Figure 3a shows the torque characteristic, while Figure 3b shows the corresponding engine power as a function of rotational speed.

2. Materials and Methods

2.1. System Architecture and Engine Model

The functional structure of the investigated closed-center load-sensing hydraulic system is presented in Figure 1. The system consists of an internal combustion engine, a variable-displacement axial piston pump, a charge pump, directional control valves, and double-acting hydraulic cylinders for lifting, tilting, and lateral displacement. The pump displacement is adjusted through a load-sensing compensator, ensuring pressure adaptation to actuator demand.
The dynamic simulation model developed in Automation Studio is shown in Figure 2. The model includes flow measurement nodes, supply pressure monitoring, actuator port pressures, and generated cylinder force. This structure allows quantitative evaluation of pressure–flow interaction during lifting operation.
The external speed characteristic of the Perkins D3900K diesel engine used as the prime mover is presented in Figure 3. The torque and power curves define the available mechanical input for the hydraulic pump and serve as the basis for the power-limited feasibility analysis described in Section 2.4.
The technical parameters of the analyzed Danfoss H1 axial piston pump sizes are summarized in Table 1. The displacement range considered in this study spans from 45 to 251.7 cm3/rev, with maximum allowable pressures up to 450 bar.
Table 1. Technical characteristics of selected Danfoss H1 axial piston pumps used in the displacement feasibility analysis.

2.2. Pump Flow Model

The hydraulic pump flow rate was calculated as a function of displacement and rotational speed using standard hydraulic pump relationships reported in the literature: [4,10]:
Q D , n = D n η v 1000 ,
where D is the pump displacement (cm3/rev);
-
n is the pump shaft speed (rpm);
-
η v is the volumetric efficiency.
A constant volumetric efficiency of 0.98 was assumed, representing typical leakage losses in axial piston pumps operating within nominal pressure limits.

2.3. Pump Torque Requirement

The input torque required to drive the pump under a given pressure level was determined from the pressure–displacement relationship:
T p D , p = D p 2 π η m ,
where p is the pump outlet pressure ( bar );
-
η m is the mechanical efficiency.
The mechanical efficiency accounts for frictional losses within the rotating group and was assumed constant for the purpose of comparative analysis.

2.4. Hydraulic Power and Engine Power Constraint

The hydraulic output power is expressed as:
P h = Q p 600 ,
where   Q is given in L / m i n and p in bar.
To ensure physical feasibility, the hydraulic power demand must not exceed the available engine power. Therefore, the maximum allowable pressure under engine power limitation was determined by imposing the condition:
P h ≤ P e ( n ) ,
which leads to the power-limited pressure envelope:
P m a x n = 600 P e ( n ) η t Q ( n ) ,
where P e is the engine power derived from the torque characteristic, and
-
η t = η v η m is the total pump efficiency.

2.5. Simulation-Based Verification

The model includes monitoring points for the pump flow rate Q, supply pressure p, actuator line flow rates QA and QB, actuator port pressures pA and pB, and cylinder force F.
The analytical results derived from Equations (1)–(5) were evaluated within the simulation environment illustrated in Figure 2. The simulation enabled verification of pressure development, flow distribution, and actuator force generation during lifting operation under varying engine speeds.
The combined analytical and simulation approach ensures that displacement feasibility is assessed not only from theoretical equations but also from system-level dynamic behavior.
The hydraulic circuit was implemented in Automation Studio as a system-level simulation model of the proposed closed-center load-sensing configuration. The model was used to reproduce the main functional interactions between the variable-displacement axial piston pump, the charge pump, the directional control valves, the actuator lines, and the hydraulic cylinders. The simulation environment enabled monitoring of pump flow rate, supply pressure, actuator port pressures, line flow rates, and generated cylinder force during representative operating conditions. In this study, Automation Studio was therefore used only as a verification tool for the analytical sizing procedure, allowing the pressure–flow behavior of the selected hydraulic architecture to be checked before the displacement feasibility results were evaluated [11].
Previous engineering investigations have shown that experimentally analyzed technical systems can serve as a basis for subsequent optimization and design-oriented improvement in related applications, including brake-fluid effects on brake-system performance [12], thermal and structural analysis of engine components [13], and efficiency investigation of thermoelectric elements [14].
The functional block diagram of the closed-center load-sensing hydraulic system is shown in Figure 2. The system is supplied by a common reservoir feeding both the main axial piston pump and the auxiliary charge pump. The main pump delivers flow Q at pressure P toward the directional control valve, while the charge pump ensures sufficient inlet pressure and compensates internal leakage losses.
Two safety overflow valves are incorporated to protect the system from excessive pressure levels during abnormal operating conditions.
The directional valve distributes flow toward either Volume Line A or Volume Line B, generating port pressures P A ,     P B , respectively. These lines are connected to a throttle valve with a spring-loaded check valve, which provides controlled flow regulation and load-holding capability.
The actuator subsystem consists of a hydraulic cylinder mechanically coupled to the lifting mechanism. The cylinder force F is transmitted to the mechanism, producing the lifting motion.
An emergency lowering button is integrated downstream of the actuator volume to ensure safe pressure relief and controlled descent in case of malfunction or power loss.
This configuration enables implementation of closed-center load-sensing control, where flow is minimized in neutral position and pressure adapts dynamically to load demand.

2.6. Operating States of the LS System

The operational states of the closed-center load-sensing hydraulic system implemented in Automation Studio are illustrated in Figure 4. The figure presents four representative operating conditions used to validate the functional behavior of the system prior to displacement feasibility analysis.
Figure 4. Operating states of the closed-center load-sensing hydraulic system in the simulation environment: (a) pump rotation at zero swash plate angle (no flow, standby condition); (b) internal flow established with directional valves in neutral position; (c) active actuation with fluid supplied to the cylinders; (d) emergency lowering mode activated. The different colored elements indicate the hydraulic components and flow paths in each operating state.
In Figure 4a, the engine is running and the pump shaft is rotating; however, the swash plate angle is set to zero. Under this condition, the pump operates at zero displacement, generating no flow. This state corresponds to standby operation in a closed-center configuration.
In Figure 4b, the swash plate angle deviates from zero and internal flow is established within the pump circuit. The directional control valves remain in the neutral (centered) position; therefore, no fluid is supplied to the hydraulic cylinders. The system operates in a compensated standby mode with pressure maintained according to load-sensing control.
In Figure 4c, the directional control valves are actuated, allowing hydraulic fluid to be delivered to the lifting, tilting, and lateral displacement cylinders. This condition represents active load operation, where pressure and flow are transmitted to the actuators to perform mechanical work.
In Figure 4d, the emergency lowering valve is activated. This configuration ensures controlled pressure release and safe actuator return in the event of valve malfunction or power interruption. The different colored elements in Figure 4 identify the main hydraulic components and flow paths in the respective operating states. The four subfigures represent standby operation, compensated standby operation, active actuation, and emergency lowering, respectively. The color coding in Figure 4 represents the hydraulic fluid state rather than fixed pressure values. Green indicates stationary fluid and a standby condition with negligible flow. Blue indicates normal fluid movement through the hydraulic circuit during actuator operation. Orange indicates pressure generation without unloading, while the hydraulic system remains within the permissible operating range and no overload condition occurs.
These operating states confirm the correct implementation of the load-sensing control logic and validate the dynamic simulation model before applying the displacement feasibility methodology.

2.7. Engine Performance Model

The engine torque and power characteristics used for the feasibility analysis are provided in Figure 3. The external speed characteristic of the Perkins D3900K diesel engine is shown in Figure 3, where Figure 3a presents the torque curve and Figure 3b illustrates the corresponding power output as a function of engine speed.
As observed in Figure 3a, the engine delivers a relatively flat torque plateau in the range of 1200–2000 rpm, with maximum torque occurring near 1400–1600 rpm. Figure 3b indicates that the engine power increases with speed and reaches its maximum value of approximately 48 kW near 2200 rpm.
The simulation model of the working hydraulics of the forklift is a tool used to describe the behavior of the hydraulic system so accurately that a reliable sensitivity analysis could be made. The basic structure of the simulation model and the signal connections between the components are shown in Figure 2.

3. Results and Discussion

3.1. Power-Limited Maximum Pressure Map

Figure 5 presents the power-limited maximum pressure as a function of engine speed for all considered H1 pump displacements, based on the Perkins D3900K torque characteristic. Each colored curve represents a different candidate pump displacement listed in Table 1. The horizontal dashed line represents the required operating pressure, and the vertical dashed lines indicate the defined working speed band. Each colored curve corresponds to a specific pump model and displacement: H1-045—45.0 cm3/rev, H1-053—53.8 cm3/rev, H1-060—60.4 cm3/rev, H1-068—68.0 cm3/rev, H1-069—69.2 cm3/rev, H1-078—78.1 cm3/rev, H1-089—89.2 cm3/rev, H1-100—101.7 cm3/rev, H1-115—115.2 cm3/rev, H1-130—130.0 cm3/rev, H1-147—147.2 cm3/rev, H1-165—165.1 cm3/rev, H1-210—211.5 cm3/rev, and H1-250—251.7 cm3/rev. As shown in Figure 5, smaller displacements maintain significantly higher allowable pressure across the entire operating range (1200–2250 rpm). In particular, the 45 cm3/rev unit sustains pressure levels close to 300 bar throughout the speed band, whereas larger displacements exhibit a substantial reduction in allowable pressure due to increased flow demand and corresponding engine power limitations.
Figure 5. Power-limited maximum pressure versus engine speed for all candidate pump displacements based on the Perkins D3900K engine model. Each colored curve represents a different pump displacement listed in Table 1. The horizontal dashed line represents the required operating pressure, and the vertical dashed lines indicate the defined working speed band.
The downward trend of p m a x ( n ) defined by Equation (5) with increasing engine speed is physically consistent. Since pump flow increases linearly with rotational speed according to Equation (1), the maximum achievable pressure must decrease to satisfy the engine power balance condition.
Displacements exceeding approximately 100 cm3 / r e v operate predominantly in the power-limited regime, with allowable pressure falling below 200 b a r at higher engine speeds. This indicates that large-displacement units are incompatible with the available engine power when high system pressures are required.

3.2. Pump Flow Characteristics

The corresponding pump flow characteristics are shown in Figure 6, where the theoretical flow rate Q(n) is plotted for all candidate displacements according to Equation (1). Figure 6 shows the pump flow characteristics for all candidate displacements as a function of engine speed. Each colored curve represents a different candidate pump displacement listed in Table 1. The horizontal dashed line indicates the required operating flow rate, and the vertical dashed lines define the working speed band. Each colored curve corresponds to a specific pump model and displacement: H1-045—45.0 cm3/rev, H1-053—53.8 cm3/rev, H1-060—60.4 cm3/rev, H1-068—68.0 cm3/rev, H1-069—69.2 cm3/rev, H1-078—78.1 cm3/rev, H1-089—89.2 cm3/rev, H1-100—101.7 cm3/rev, H1-115—115.2 cm3/rev, H1-130—130.0 cm3/rev, H1-147—147.2 cm3/rev, H1-165—165.1 cm3/rev, H1-210—211.5 cm3/rev, and H1-250—251.7 cm3/rev.
Figure 6. Pump flow characteristics for all candidate displacements as a function of engine speed.
As illustrated in Figure 6, pump flow increases linearly with engine speed for all displacement values. Large-displacement units generate excessive flow rates relative to typical forklift hydraulic requirements. For instance, at 2200 rpm, a 250 cm3/rev pump would theoretically deliver more than 500 L/min, which substantially exceeds realistic operational needs for lifting and tilting functions.
In contrast, displacements in the range of 45–78 cm3 / r e v produce flow rates between approximately 50 and 100 L / m i n across the working speed band (Figure 6), which aligns with practical forklift hydraulic demands.

3.3. Engine–Pump Matching Implications

The combined interpretation of Figure 5 and Figure 6 highlights the classical trade-off inherent in engine–pump matching.
Increasing pump displacement leads to higher available flow (Figure 6), but simultaneously reduces the allowable system pressure due to engine power constraints (Figure 5). For the imposed design condition of 300 b a r and 80 L / m i n , the 45 cm3 / r e v displacement demonstrates the highest feasibility across the operational band.
Larger displacements progressively enter the power-limited region, particularly at higher engine speeds, as evidenced by the divergence between required operating pressure and the power-limited curves in Figure 5.
From an engineering standpoint, the Perkins D3900K engine (maximum power approximately 48 k W ) can sustain approximately 80 L / m i n at 300 b a r only near its peak torque region (see Figure 4). Continuous operation beyond this envelope would require pressure reduction, flow limitation, or intermittent duty cycles.

4. Conclusions

This study presented a displacement feasibility methodology for a closed-center load-sensing hydraulic system applied to an industrial forklift powered by a Perkins D3900K diesel engine.
The analysis combined analytical modeling and dynamic simulation to evaluate the influence of pump displacement on flow capacity and allowable system pressure under engine power constraints. The derived power-limited pressure envelope demonstrated that pump oversizing leads to persistent operation in the power-limited regime, especially at higher engine speeds.
The main findings can be summarized as follows:
  • The maximum achievable hydraulic pressure decreases with increasing engine speed due to the linear growth of pump flow and the finite engine power availability;
  • Pump displacements above approximately 100 cm3/rev are not technically justified for the investigated engine configuration, as they operate predominantly under power-limited conditions;
  • Displacements in the range of 45–60 cm3/rev provide the most balanced compromise between pressure stability and practical flow delivery (50–100 L/min) within the 1200–2250 rpm operating band;
  • Continuous operation at 300 bar and 80 L/min is feasible only near the peak torque region of the engine. At higher speeds, pressure limitation or flow reduction is required to maintain power balance.
The proposed methodology integrates engine characteristics, hydraulic equations, and system-level simulation into a unified displacement selection approach. This framework can be applied during preliminary design stages of load-sensing hydraulic systems in mobile machinery to prevent oversizing and improve overall energy efficiency.
Future work may include transient analysis under multi-actuator operation and experimental validation of the proposed displacement selection strategy.

Funding

This research was funded by the European Regional Development Fund within the OP “Research, Innovation and Digitalization Programme for Intelligent Transformation 2021–2027”, Project No. BG16RFPR002-1.014-0005, Center of Competence “Smart Mechatronics, Eco- and Energy-Saving Systems and Technologies”.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Data are contained within the article.

Conflicts of Interest

The author declares no conflicts of interest.

Abbreviation

The following abbreviation is used in this manuscript:
LSLoad-Sensing

References

  1. Gramatikov, I. Design of Hydraulic Systems for Lift Trucks, 1st ed.; Technical University of Sofia: Sofia, Bulgaria, 2011; 260p. [Google Scholar]
  2. Krogerus, T.; Rokala, M.; Koskinen, K.T. Sensitivity Analysis of Data Analysis Process in Hydraulic Forklift. In Proceedings of the 8th JFPS International Symposium on Fluid Power, Okinawa, Japan, 25–28 October 2011; ISBN 4-931070-08-6. [Google Scholar]
  3. Miu, P. Combine Harvesters: Theory, Modeling, and Design; CRC Press: Boca Raton, FL, USA, 2016. [Google Scholar]
  4. Stryczek, J.; Warzyńska, U. (Eds.) Advances in Hydraulic and Pneumatic Drives and Control 2020; Springer Nature: Cham, Switzerland, 2021. [Google Scholar]
  5. Quanyi, H.; Hong, Z.; Shujun, T.; Xuxin, Q. Performance Analysis of a Novel Load-Sensing Hydraulic System with Overriding Differential Pressure Control. Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 2016, 231, 23. [Google Scholar] [CrossRef] [Scilit]
  6. Wang, H.; Feng, Z. A Review of Flow Saturation Resistant Techniques in Multi-Actuator Load-Sensing Hydraulic Systems. J. Eng. Mech. Mach. 2023, 8. [Google Scholar] [CrossRef] [Scilit]
  7. Danfoss. Series H1 Axial Piston Pumps Technical Information. Available online: https://bibus-pim-production-storage.sos-ch-dk-2.exoscale-cdn.com/media/filer_public/dc/7e/dc7e952d-5e24-4936-8b41-461d919fc2c0/sauer_danfoss_axial_piston_pumps_series_h1.pdf (accessed on 12 May 2026).
  8. Tashev, A.; Dimitrov, E. Investigation of LPG influence on cylinder pressure of VW 1.9D diesel engine operating in dual-fuel mode. AIP Conf. Proc. 2025, 3274, 060003. [Google Scholar] [CrossRef] [Scilit]
  9. Mitev, P. Development of a Training Station for the Orientation of Dice Parts with Machine Vision. Eng. Proc. 2024, 70, 57. [Google Scholar] [CrossRef] [Scilit]
  10. Srivastava, A.; Goering, C.; Rohrbach, R.; Buckmaster, D. Engineering Principles of Agricultural Machines; American Society of Agricultural and Biological Engineers: Saint Joseph, MI, USA, 2006. [Google Scholar]
  11. Famic Technologies. Automation Studio: System Design and Simulation Software. Available online: https://www.famictech.com/en/ (accessed on 12 May 2026).
  12. Mladenov, G.; Kuzmanov, N.; Hristov, V. Research on and Analysis of Brake Fluid Impact on Brake System Performance. Eng. Proc. 2025, 100, 27. [Google Scholar] [CrossRef] [Scilit]
  13. Ambarev, K.; Taneva, S. Thermal and Structural Analysis of Gasoline Engine Piston at Different Boost Pressures. Eng. Proc. 2025, 100, 38. [Google Scholar] [CrossRef] [Scilit]
  14. Radulov, A.; Dechev, M.; Matsankov, M. Investigation of the Efficiency of a Peltier Element. Eng. Proc. 2025, 100, 8. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.