Abstract
Recent studies have demonstrated that methods for determining antioxidant activity based on the chromogenic change of transition metal complexes following the reduction of the metal ion oxidation state may, in biological matrices, reflect the potential pro-oxidant activity of compounds through Fenton and so-called Fenton-like reactions. Fenton and Fenton-like reactions comprise the redox reactions of iron, copper, cobalt, manganese, chromium, vanadium, titanium, nickel, and other transition metal ions. In addition to hydrogen peroxide, these reactions may proceed in the presence of oxidants such as peroxymonosulfates, persulfates (peroxydisulfates), hypochlorides, organic hydroperoxides, and lipid hydroperoxides. The physiological impact of these reactions on biological and other complex chemical systems is significant. Therefore, understanding the mechanisms governing these reactions is essential. The aim of this study was to validate an improved methodology for the Ferric Reducing Antioxidant Power (FRAP) assay, followed by the evaluation of ten model antioxidant compounds and the interpretation of the obtained results. The ability of these compounds to reduce Fe3+ ions in the 2,4,6-tris(2-pyridyl)-s-triazine (TPTZ) complex was found to be influenced primarily by molecular complexity (from database sources), including the number of heteroatoms, and secondarily by the number of aromatic rings and double bonds within the molecular structure of tested antioxidants.
1. Introduction
The demand for antioxidants remains highly relevant today, spanning the fields of both product stability and human and veterinary medicine [1]. There are growing requirements for applied antioxidants in terms of their efficacy, safety profile, and stability [2].
Currently, the potential pro-oxidant effect is being rigorously investigated, highlighting the fact that many potent, well-known antioxidants simultaneously exhibit strong pro-oxidant activity [3].
A pilot study of 22 randomly selected substances with putative antioxidant activity, along with selected plant extracts, has been published; it utilized a unique, simultaneous microplate-based method to determine both antioxidant activity via the DPPH assay and potential pro-oxidant activity via the FRAP assay using a shared dilution mode [4].
The Ferric Reducing Antioxidant Power (FRAP) assay remains one of the fundamental methods used to assess antioxidant capacity. The Ferric Reducing Antioxidant Power (FRAP) assay is a widely used spectrophotometric method for estimating the total antioxidant capacity of biological samples, plasma samples, foods, beverages, and plant extracts. It is based on the ability of antioxidants to reduce Fe3+ to Fe2+ under acidic conditions [5].
This method is cost-effective and reproducible; however, its primary limitation lies in the fact that it is conducted under non-physiological conditions at an acidic pH, and certain antioxidants react only slowly [6].
The work of Maliar et al., among other studies, has demonstrated that while the reduction of Fe3+ to Fe2+ reflects the antioxidant effect of the tested samples, the resulting reaction product is the substantially more pro-oxidative Fe2+ ion species. In Fenton and Fenton-like reactions, these ions subsequently generate additional radical-type reactive oxygen species /ROS/ [7]. Fenton and Fenton-like reactions comprise the redox reactions of iron, copper, cobalt, manganese, chromium, vanadium, titanium, nickel, and other transition metal ions. In addition to hydrogen peroxide, these reactions may proceed in the presence of oxidants such as peroxymonosulfates, persulfates (peroxydisulfates), hypochlorides, organic hydroperoxides, and lipid hydroperoxides [8].
Accordingly, several published studies have highlighted a significant pro-oxidant effect exhibited by well-known antioxidants, flavonoids, and other natural compounds [9,10].
The rationale for this study stems from the fact that the methodology used to determine antioxidant activity using the FRAP assay varies to some extent, which may account for the partially discrepant results reported for the same compound by different authors. Accordingly, compounds with well-documented antioxidant activity that had been independently investigated by more than one research group were selected for this study. Furthermore, these compounds were evaluated using a methodology that differed from that described by the authors in reference [4], in which the FRAP assay was substantially modified to enable the simultaneous application of the DPPH assay using a single, common solvent system for both methods, thereby minimizing the potential for systematic error.
Thus, the objectives of this study were threefold: (i) to select a set of well-characterized antioxidants that had previously been investigated by different research groups; (ii) to apply the newly adapted FRAP method; and (iii) to further optimize the method for determining FRAP50 values, with the aim of improving assay precision. Furthermore, this work aimed to identify the key structural molecular parameters of the tested substances in relation to their ferric-reducing capacity while considering the potential pro-oxidant activity of these active entities.
2. Materials and Methods
2.1. Chemicals
The study included compounds that are well-known for their antioxidant activity and had previously been evaluated using the FRAP assay, albeit under different experimental designs. The compounds investigated were as follows: Tannic acid, Gallic acid, Quercetin, Caffeic acid, (-)-Catechin, 6-Hydroxy-2,5,7,8-tetramethylchromane-2-carboxylic acid /Trolox/, 7,8-Dihydroxyflavone, 1,4-Dithiothreitol, L-Ascorbic acid, Rutin, 2,4,6-Tri(pyridin-2-yl)-1,3,5-triazine /TPTZ/, Sodium acetate, Acetic acid, FeCl2·4H2O, FeCl3·4H2O, Ethanol were obtained from Merck /Sigma Aldrich/ (Darmstadt, Germany) with declared purity over 98%.
2.2. Antioxidant and Potential Pro-Oxidant Activity Determination Through Modified FRAP Assay
The modified FRAP method on microplate used to measure the antioxidant and pro-oxidant properties of tested compounds comes from the paper by Maliar et al. [4]. The method was performed on microplates ensuring equal concentrations of both key reagents (TPTZ, and FeCl3) at 0.4 mM. Briefly, separate solutions A and B were prepared, with solution A containing 0.0187 g of TPTZ in 10 mL of ethanol and solution B containing 0.338 g of sodium acetate in 88.3 mL of water and 1.748 mL of acetic acid. These solutions were mixed freshly before each experiment to form FRAP starting reagent. Additionally, 1.2 mM solutions of FeCl2·4H2O and FeCl3·6H2O were prepared fresh prior to the experiments.
In the first column (column 1), a 100% conversion standard solution of FeCl2·4H2O was used instead of the sample. In contrast, in the last column (column 12), a 0% conversion standard was applied using a solution of FeCl3·6H2O instead of the sample. Columns 1–11 mean the testing range area.
For methodological optimization, three different dilution modes were applied.
Mode 1, dilution on 1/2 concentration (100 μL of tested sample solution into column 2, 50 μL of ethanol into columns 3–10), transfer of 50 μL in the direction of columns 2–11 using one 8-channel micropipette.
Mode 2, dilution on 2/3 concentration (150 μL of tested sample solution into column 2, 50 μL of ethanol into columns 3–10), transfer of 100 μL in the direction of columns 2–11, and removal of 50 μL from last row out using one 8-channel micropipette.
Mode 3, dilution on 3/4 concentration (200 μL of tested sample solution into column 2, 50 μL of ethanol into columns 3–10), transfer of 150 μL in the direction of columns 2–11, and removal of 100 μL from last row out using one 8-channel micropipette. Tested compounds were tested in appropriate concentration interval. Starting concentration depends on FRAP efficiency, generally from interval (204, 4092 μM). Then, it was added 50 μL of FeCl3·6H2O solution to the testing area of the microplate.
To rows F, G, and H (background field area) was added 100 μL of 10% ethanol instead of FRAP starting reagent. Then, the microplate was initialized by adding 100 μL of FRAP starting reagent to rows A, B, C, D, and E.
The microplate was incubated for 1 h for the FRAP assay at room temperature, followed by measurements at 630 nm.
Primarily, the measured absorbance values were refined by subtracting background values (average of three wells in rows F, G, and H). Secondarily, refined absorbance value in the testing range were converted to a % of conversion values. Then, the FRAP50 values were calculated from the following linear function plot: percentage of conversion = f(concentration).
Each experiment was repeated three times with eight replicates, with results presented as mean ± SD. Statistical significance was determined using the Spearman method (* p < 0.1).
2.3. Database Sources
All chosen parameters, particularly MW—molecular weight, XlogP3—computed by XLogP3 3.0, HBDC—hydrogen bond donor count, HBAC—hydrogen bond acceptor count, RBC—rotatable bond count, HAC—heavy atom count, and COMP—complexity value, were taken from the PubChem database (https://pubchem.ncbi.nlm.nih.gov, accessed on 11 July 2026).
3. Results and Discussion
The Results and Discussion section of the present study comprises two main parts. The first part presents the results of method optimization using three different dilution modes, with the aim of obtaining the most accurate FRAP50 values for 10 selected compounds. The second part focuses on a correlation analysis of the obtained FRAP50 values and selected structural parameters, with the aim of identifying potential relationships between these variables.
3.1. FRAP Assay
The first part of the study focuses on the accuracy of FRAP50 determination using three different dilution modes applied sequentially. Specifically, serial dilution was performed across columns 2–11 of the microplate within the so-called testing range area. In Mode 1, the concentration was reduced to one-half of the preceding concentration in each subsequent column; in Mode 2, the concentration was reduced to two-thirds; and in Mode 3, the concentration was reduced to three-quarters.
The aim of these approaches was to extend the so-called transition interval and thereby include as many data points as possible within the calculation range (10–90% conversion), ultimately increasing the accuracy of FRAP50 determination. The results obtained for the 10 selected compounds are presented in Table 1.
Table 1.
Measured FRAP50 values ± SD, N—number of data points included in the calculation, r2—Pearson’s coefficient of determination for the 10 selected compounds using three different dilution modes.
Table 1 presents the measured results in an appropriate manner, with the parameters N and r2 clearly reflecting the quality of FRAP50 determination. The applied dilution modes demonstrate a clear improvement in the accuracy of FRAP50 determination, progressing from Mode 1 (1/2 dilution) through Mode 2 (2/3 dilution) to Mode 3 (3/4 dilution). The number of data points included in the FRAP50 calculation increased from an average of 4.9 to 6.0 and 8.2, respectively. Similarly, the coefficient of determination (r2) increased from a relatively low value of 0.932 to 0.939 and 0.957, respectively.
Regarding the ability of the tested compounds to reduce the Fe3+–TPTZ complex, the FRAP values varied considerably depending on the dilution mode applied. Therefore, when comparing the tested compounds, conclusions should always be based on a consistent series of results obtained using the same dilution mode. Based on the accuracy parameters, the values obtained using the 3/4 dilution mode were selected for the subsequent part of the study.
3.2. Correlation Analysis
As part of the correlation analysis, the measured FRAP50 values were correlated with basic structural parameters. The structural parameters were selected based on previously published evidence suggesting a causal relationship with the ability of the compounds to reduce the Fe3+–TPTZ complex. The following parameters were considered: MW—molecular weight, XlogP3—computed by XLogP3 3.0, HBDC—hydrogen bond donor count, HBAC—hydrogen bond acceptor count, RBC—rotatable bond count, HAC—heavy atom count, COMP—complexity value, all taken from the PubChem database. Input data for analysis are presented in Table 2.
Table 2.
Input data for correlation analysis of ten chosen compounds (with identification via CAS number), particularly values for the following parameters: /FRAP50, MW, XlogP3, HBDC, HBAC, RBC, HAC, and COMP/.
The results of the correlation analysis, expressed as Pearson correlation coefficients of determination between the individual variables, are presented in Table 3.
Table 3.
Correlation analysis table of Pearson coefficients of determination for the following parameters: /FRAP50, MW, XlogP3, HBDC, HBAC, RBC, HAC, and COMP/.
The correlation analysis revealed only a weak negative correlation between the output parameter FRAP50 and the selected variables. In this context, it should be noted that antioxidant activity (and, simultaneously, potentially pro-oxidant activity) increases with decreasing FRAP50 values. Thus, for most of the parameters, the observed activity increases with increasing values of the selected variables, which primarily reflect molecular size.
A significant negative correlation was observed for the polarity parameter, specifically XlogP3. This finding suggests a surprising, and potentially previously unreported, relationship: the efficacy of the FRAP method decreases with increasing hydrophilicity and, conversely, increases with increasing molecular lipophilicity.
The pronounced pro-oxidant effect observed for tannic acid and quercetin was also unexpected, as was the relatively lower effect observed, for example, for ascorbic acid.
4. Conclusions
The investigation of compounds and their ability to reduce the Fe3+–TPTZ complex is of great importance for understanding the mechanisms underlying the undesirable pro-oxidant activity of compounds and antioxidants. Identifying relationships between selected variables and the FRAP50 parameter requires sophisticated methods of advanced chemometrics. However, the significance of this research would be further enhanced by parallel, ideally simultaneous, determination of antioxidant activity. Such an approach could have significant implications for practical applications, therapeutic interventions, and the prevention of serious human and veterinary diseases.
Author Contributions
Conceptualization, T.M. and N.K.; methodology, T.M., M.M. and R.G.; software, T.M.; validation, M.M.; formal analysis, R.G.; investigation, T.M. and N.K.; resources, T.M.; data curation, N.K. and R.G.; writing—original draft preparation, T.M.; writing—review and editing, N.K. and M.M.; visualization, R.G.; supervision, T.M.; project administration, T.M.; funding acquisition, T.M. All authors have read and agreed to the published version of the manuscript.
Funding
This research was supported by grants SRDA-24-0180.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
Data are available in this manuscript.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Gulcin, I. Antioxidants: A comprehensive review. Arch. Toxicol. 2025, 99, 1893–1997. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Dobrowolska-Iwanek, J.; Zagrodzki, P.; Woźniakiewicz, M.; Woźniakiewicz, A.; Zwolińska-Wcisło, M.; Winnicka, D.; Paśko, P. Procedure optimization for extracting short-chain fatty acids from human faeces. J. Pharm. Biomed. Anal. 2016, 124, 337–340. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Poljsak, B.; Suput, D.; Milisav, I. Achieving the Balance between ROS and Antioxidants: When to Use the Synthetic Antioxidants. Oxid. Med. Cell. Longev. 2013, 20, 3725–3736. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Maliar, T.; Maliarová, M.; Blažková, M.; Kunštek, M.; Uváčková, Ľ.; Viskupičová, J.; Purdešová, A.; Beňovič, P. Simultaneously Determined Antioxidant and Pro-Oxidant Activity of Randomly Selected Plant Secondary Metabolites and Plant Extracts. Molecules 2023, 28, 6890. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Benzie, I.F.; Strain, J.J. The ferric reducing ability of plasma (FRAP) as a measure of “antioxidant power”: The FRAP assay. Anal. Biochem. 1996, 239, 70–76. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rubio, C.P.; Hernández-Ruiz, J.; Martinez-Subiela, S.; Tvarijonaviciute, A.; Cerón, J.J. Spectrophotometric assays for total antioxidant capacity (TAC) in dog serum: An update. BMC Vet. Res. 2016, 12, 166. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Abe, C.; Miyazawa, T.; Miyazawa, T. Current use of Fenton reaction in drugs and food. Molecules 2022, 27, 5451. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Meyerstein, D. Re-examining Fenton and Fenton-like reactions. Nat. Rev. Chem. 2021, 5, 595–597. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lambert, J.D.; Elias, R.J. The antioxidant and pro-oxidant activities of green tea polyphenols: A role in cancer prevention. Arch. Biochem. Biophys. 2010, 501, 65–72. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Procházková, D.; Boušová, I.; Wilhelmová, N. Antioxidant and prooxidant properties of flavonoids. Fitoterapia 2011, 82, 513–523. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.