Skip to Content
You are currently on the new version of our website. Access the old version .
  • Article
  • Open Access

16 November 2026

45 Pages

Deciphering Temperature–Humidity Coupling in Proton Exchange Membrane Fuel Cells: Multiphysics Insights into Performance, Water Management, and Operating Limits

,
,
,
and
1
Marine Engineering Technology, Sharjah Maritime Academy, Sharjah P.O. Box 180018, United Arab Emirates
2
Mechanical Engineering Department, Faculty of Engineering, Mutah University, Al-Karak 61710, Jordan
3
Defence and Security Program, Rabdan Academy, Abu Dhabi P.O. Box 114646, United Arab Emirates
4
Maritime Logistics and Supply Chain Management (MLSCM), Sharjah Maritime Academy, Sharjah P.O. Box 180018, United Arab Emirates
Clean Technol.2026, 8(6), 188;https://doi.org/10.3390/cleantechnol8060188 
(registering DOI)

Abstract

Climate-driven temperature and humidity extremes can substantially alter the coupled electrochemical, thermal, and transport processes governing proton exchange membrane fuel cell (PEMFC) performance, yet their implications for environmental resilience remain insufficiently quantified. This study develops a three-dimensional, non-isothermal multiphysics framework to assess PEMFC operation across 16 temperature–relative-humidity scenarios spanning 20–80 °C and 20–100% RH. Electrochemical kinetics, species and heat transport, membrane hydration, liquid-water behavior, oxygen availability, and spatial current-density characteristics are evaluated concurrently to identify environmentally induced operating limitations. The results reveal two competing failure regimes: hot–dry exposure promotes membrane dehydration, increased protonic resistance, spatial non-uniformity, and severe power deterioration, whereas excessive humidification progressively increases liquid-water accumulation, oxygen-transport resistance, pressure drop, and auxiliary pumping requirements. A balanced regime emerges around 60 °C and 80% RH (C11), where membrane hydration and oxygen accessibility are simultaneously maintained. Under this condition, oxygen utilization reaches approximately 79.4%, the admissible current density increases to 1.98 A cm−2, and net power density reaches approximately 1.04 W cm−2. In contrast, the hot–dry C13 condition restricts the admissible current density to 0.74 A cm−2 and reduces net power density to approximately 0.49 W cm−2. The findings demonstrate that PEMFC climate resilience is governed by the balance between hydration preservation and reactant/water transport rather than optimization of temperature or humidity independently, providing a physics-based basis for climate-adaptive control and robust hydrogen-power-system design.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.