Design of the Electric Power Control System for a Hydrogen-Fed AEMFC Polymeric Fuel Cell Generator to Power a 0.75 KW DC Motor

,
and
Departamento de Energía Eléctrica y Automática, Facultad de Minas, Universidad Nacional de Colombia, Sede Medellín, Carrera 80 No. 65-223, Robledo, Medellín 050034, Colombia
*
Author to whom correspondence should be addressed.

Abstract

Mitigating pollution in cities where transportation powered by fossil fuels has a significant impact on human health is a public health priority. Although electric vehicles are one solution to this problem, their high acquisition and maintenance costs have limited their rapid adoption; therefore, other solutions may be useful in supporting reduction efforts. Therefore, this paper proposes a power control system for an Anion Exchange Membrane Fuel Cell (AEMFC) generator powered by hydrogen with the capacity to supply a direct current (DC) motor of 0.75 kW. A mathematical model of the AEMFC was proposed, and the parameters were adjusted to obtain polarization and power curves defining safe operating ranges (12.45–17.9 V). A boost converter was designed to increase the voltage of the cell output to 48 V to meet the requirements of the DC motor. The performance of the power converter was studied by analyzing its small-signal ripple, operating modes, and efficiency. The models and simulations were implemented using MATLAB and PSIM. A cascaded control system with proportional–integral (PI) and proportional–integral–derivative (PID) controllers was implemented to maintain voltage stability in the presence of input and load variation. The results show that the AEMFC is reliable and that the boost converter presents an efficiency higher than 98% in continuous mode. The robustness of the model was validated through simulations and using a prototype.

1. Introduction

The increasing energy demand and the necessity to reduce carbon emissions have driven the development of new technologies, such as fuel cells, for converting hydrogen into electricity [1,2]. Anion Exchange Membrane Fuel Cells (AEMFC) are a promising solution because of their economic and technical feasibility compared to traditional Proton Exchange Membrane Fuel Cells [3]. Some advantages of this technology are the improved oxygen reduction reaction kinetics within alkaline media [4,5,6], the option to integrate non-precious metal catalysts, leading to cost reduction for stacks [1,5], and augmented component lifespan through the suppression of aggressive corrosive phenomena [4,5]. Nonetheless, the optimization of these technologies and their integration with compact devices and electronic power systems remain a central challenge that demands advances in materials, modeling, and control. In addition, challenges persist in water management and carbonation [6,7,8]. The use of nanometric additives, such as graphene oxide, added to the modification of compounds, the skeletal regulation of the polymer, the design of geometric structures, the adjustment of the electrolyte concentration, and the experimentation with various operating temperatures have made it possible to significantly improve its stability and ionic conductivity, thus driving the transition of AEM membranes from the basic research phase to industrial-scale applications [9,10,11].
In the transportation sector, recent advances in polymer electrolyte fuel cells (PEMFCs) have allowed the proliferation of hybrid vehicles powered by this technology, given their high-efficiency characteristics and zero-emission environmental advantages [12,13]. The global market for hydrogen fuel cell vehicles is estimated to reach $2.1 billion by 2024 [14]. However, their mass adoption remains limited by the high cost of platinum catalysts and the scarcity of critical materials. Given these limitations, AEMFCs have gained attention as favorable alternatives with broad prospects for integration into the automotive industry.
Mathematical modeling of AEMFCs is an essential step for predicting their behavior under real load conditions [7]. Currently, the use of new continuous improvement strategies based on Artificial Intelligence (AI) and Machine Learning (ML) makes it possible to optimize the performance of AEMFCs through the precise parameterization of materials and internal processes [15]. Therefore, establishing a model that accurately represents the electrical response to experimental variables forms the basis for the design of control strategies and power conditioning using DC–DC converters, which manage the critical coupling between the cell and the load [16,17,18].
However, studies that address the dynamic link between these components in an integrated manner are limited. In the literature, the Ballard Nexa 1.2 kW model for PEMFC has been frequently used as a basis for determining the appropriate parameters under various operating conditions [19]. However, the distinct nature of AEMFCs motivates this research to focus on collaborative system-level design.
This study developed a power conversion and control system for a 1 kW generator based on hydrogen-fed AEMFC cells. The proposed model allows the prediction of the electrical and transient responses of cells under load variations. A power stage was created with a boost converter to ensure voltage elevation up to 48 V to drive a 0.75 kW DC motor. Additionally, the influence of membranes modified with graphene oxide nanoparticles on the overall efficiency and durability of the system was evaluated. The boost converter was designed to maximize the efficiency of the cell operating in the range of 12–18 V, considering the ripple, conduction modes, and stability under transient events. The design is complemented by a cascade control strategy that combines an internal current loop and an external voltage loop, allowing the output to be regulated even under load disturbances or cell fluctuations [20,21]. This approach has proven to be especially robust in nonlinear source applications and is reinforced with anti-windup techniques that prevent the saturation of the PI/PID controllers, preserving dynamic stability [18].
The results obtained from the simulation (MATLAB/PSIM) show that the proposed system achieves efficiencies greater than 98% in continuous mode, with minimal voltage variation under disturbances. Furthermore, the integration of the nano-modified material into the membrane improves conductivity and reduces ohmic losses, resulting in higher power density. This performance confirms the viability of the controlled AEMFC–boost hybrid architecture, offering a competitive alternative for urban hydrogen-based mobility applications.
In addition, this study contributes to strengthening applied research on hydrogen systems, demonstrating that the combination of detailed modeling, efficient electronic design, and robust control strategies can enable clean and economically sustainable energy solutions. To this end, a high-efficiency boost converter was designed, optimized for the cell range (12.45–17.9 V), and integrated with a cascaded control strategy (inner current loop and outer voltage loop) along with anti-windup techniques to preserve stability against disturbances [18,20,21]. The results obtained in MATLAB/PSIM demonstrated efficiencies exceeding 98% and confirmed that the integration of nano-modified materials reduced ohmic losses, thereby improving the power density [22]. Finally, this study constitutes an original development that transcends generic theoretical models. A control architecture specifically tuned with experimental laboratory parameters is presented, where every model and equation is validated for real 0.75 kW operating conditions, ensuring traceability and internal consistency of the methodology against the requirements of electric micromobility.

2. Mathematical Modeling of the AEMFC

The performance of an AEMFC requires a mathematical model that captures its electrochemical and dynamic behaviors under diverse operating conditions. This model is essential for the design and control of a DC/DC converter that conditions the power generated by the cell to power a static 1 kW load. The model development was structured in two main phases: (1) electrochemical analysis and state-space linearization, and (2) design of the power conditioning system, which is addressed in the later sections of this paper.

2.1. Electrochemical Efficiency and Polarization Curve

The electrochemical efficiency of the AEMFC was evaluated by comparing the theoretical potential, calculated using the Nernst equation, with the actual voltage measured under load conditions. Unlike thermal machines, whose efficiency is limited by the Carnot cycle and depends on temperature gradients, fuel cells, such as AEMFC, directly convert chemical energy into electricity without temperature-related thermodynamic restrictions. This is because the reactants (hydrogen and oxygen) and products (water) enter and leave the system under ambient conditions, resulting in zero thermal energy flow. The maximum theoretical efficiency is defined as the ratio between the Gibbs free energy ( Δ G ) and the total enthalpy of the reaction ( Δ H ):
η m a x = Δ G Δ H
For a typical hydrogen and oxygen reaction in an AEMFC, Δ G = − 237.2 , k J / m o l and Δ H = − 285.8 , k J / m o l at 25 °C y 1 atm, resulting in an η m a x ≈ 83 % . However, in practice, internal losses significantly reduce efficiency. The polarization curve, which relates the cell voltage ( V c e l l ) to the current density ( J ) , was modeled considering three main types of voltage losses:
Activation losses occur because of the energy required to initiate the electrochemical reaction at the electrodes and are more pronounced at low current densities. They were calculated using Equation (2). The term I F C is the current passing through the cell; ζ 1 , ζ 2 , ζ 3 , ζ 4 are experimental coefficients whose values depend on each type of cell; and C O 2 is the oxygen concentration at the cathode-catalyst interface (expressed in mol/cm3).
V a c t = ζ 1 + ζ 2 ⋅ T + ζ 3 ⋅ T ⋅ ln ( C O 2 ) + ζ 4 ⋅   T ⋅ ln ( I F C )  
Ohmic Losses or resistive losses are caused by the opposition of the electrodes and electrolyte to the flow of electrons. The membrane resistance can be determined from its resistivity, which varies according to the material used. For instance, in the case of a Nafion membrane (a registered trademark of Dupont), commonly used in Polymer Electrolyte Membrane (PEM) fuel cells, the resistivity ρ m is calculated using Equation (3):
ρ m = 181.6 ⋅ [ 1 + 0.03 ⋅ ( I F C A ) + 0.062 ⋅ ( T 303 ) 2 ⋅ ( I F C A ) 2.5 ] [ φ − 0.634 − 3 ⋅ ( I F C A ) ⋅ e − 498 T ] ⋅ e − 498 T
These losses follow Ohm’s law. To determine the value of ohmic losses, a distinction is made between membrane resistance ( R m ) and electrode resistance ( R c ). The membrane resistance depends on its resistivity, material type, and constructive geometry. The calculation of ( R m ) is based on its resistivity ρ m and is calculated as in Equation (4).
R m = ρ m ⋅ L A
The term A is the cell area and L is the membrane thickness. Thus, the potential drop due to resistive losses is calculated using Equation (5) [23].
V o h m = I F C ⋅ ( R m + R c   ) = I F C   ( ρ m ⋅ l A + R c )  
Concentration Losses occur at high current densities due to the limitation of the diffusion of reactants to the active sites of the electrodes. They were modeled using Equation (6) [23], where B is a parameter depending on the cell type and J represents the instantaneous current density (A/cm2).
V c o n c = B ⋅ l n ( 1 − J J m a x )  
Finally, the total cell voltage was calculated using Equation (7):
V c e l   =   E N e r n s t   −   V a c t   −   V o h m   −   V c o n c
The term E N e r n s t is the reversible potential, determined by:
E N e r n s t   =   1.229 − ( 8.5 ⋅ 10 − 4 ) ⋅ ( T − 298.15 ) − ( 4.308 ⋅ 10 − 5 ) ⋅ T ⋅ ( ln ( P H 2 ) + 1 2 ⋅ P O 2 )
The term P H 2 and P O 2 are the partial pressures of hydrogen and oxygen, respectively. These pressures directly affected the reaction kinetics and were adjusted in the simulations according to the operating conditions described in Table 1.
Table 1. Parameters and their influence on cell behavior.

2.2. Electrical Modeling and Dynamic Behavior

The electrical behavior of the AEMFC was represented by a static model based on an equivalent circuit model. This circuit includes controlled voltage sources for E N e r n s t , V a c t , y V c o n c , in series with a variable resistance representing V o h m . Figure 1 illustrates this configuration and shows how the losses are distributed throughout the circuit.
Figure 1. Equivalent static electric model of fuel cell.
To capture the dynamic behavior, the double-layer capacitance effect was incorporated, arising from charge storage at the interface between the electrode and electrolyte. This introduces a delay in the voltage response, which is a critical aspect of DC/DC converter design. The dynamic model was represented by an RC network (Figure 2), where the time constant τ is defined as:
τ   =   R C
Figure 2. Equivalent dynamic electric model of a fuel cell, including RC elements to consider double-layer effects [24].
The equivalent resistance is calculated as
R = V a c t + V c o n c i
The capacitance C depends on the electrode properties and can vary between 0.1 and 1 F . For a stack of N cells connected in series, the total voltage is:
V s t a c k   =   N V c e l l

2.3. Simulation and Parameter Identification

The model was implemented in MATLAB/Simulink 2018a, using the constitutive equations of the 1.2 kW Ballard Nexa model as a baseline. In this study, operating parameters such as a temperature of 298 K and partial pressures of 1 atm for H 2 and O 2 were calibrated and experimentally iterated using experimental data. This adjustment process validated that the mathematical model faithfully represented the alkaline kinetics of the cell. The resulting simulations generated the polarization and power curves, identifying the Maximum Power Point (MPP) at approximately 0.6 V per cell for a 28-cell stack. This performance is consistent with the typical behavior of anion-exchange membranes and establishes the nominal operating point for the control system.
It is essential to clarify that although the mathematical structure of overpotentials (activation, ohmic, and concentration) is analogous across polymeric technologies, the empirical coefficients ζ 1 to ζ 4 presented in Table 1 have been specifically calibrated for AEMFC kinetics. Unlike PEM cells, the alkaline medium of the AEMFC allows the use of non-precious catalysts and exhibits distinct oxygen reduction reaction (ORR) kinetics. This is reflected in the adjustment of the internal resistance and Nernst reversible potential using experimental data. Therefore, the model is not a PEM technology extrapolation but an experimentally validated parametric adaptation for the anionic electrolyte used in this study. As a result of this adjustment, Figure 3 presents the polarization curve obtained through the MATLAB simulation, establishing the characteristic relationship between the voltage and current density that governs the behavior of the stack.
Figure 3. Polarization curve obtained through MATLAB simulation.
In addition to this theoretical validation, experimental results provided by the GRIEQUI research group were integrated, reflecting the physical behavior of the test bench prototypes under various geometric architectures and feeding configurations. Figure 4 presents the polarization and power density curves for the self-breathing cell configuration, while Figure 5 illustrates a comparative analysis of the best geometries obtained in the laboratory. This synergy between the parameterized mathematical model and experimental baseline ensures that the control strategy is robust against the intrinsic dynamic variations in AEMFC cells.
Figure 4. Simulation results for a breathing cell: (a) polarization curve and (b) power density curve.
Figure 5. Comparison of best geometries for different feeding configurations: (a) polarization curve and (b) power density curve.

2.4. State-Space Representation and Linearization

Considering a generic equilibrium point for fuel cell operation in the form ( X , U ) = ( V F C , I F C ) , the model approximates the incremental variations in the nonlinear system around this equilibrium point, expressed through Equations (12) and (13):
x ˙ δ ( t ) = A δ ( X , U ) x δ ( t ) + B δ ( X , U ) u δ ( t )
y δ ( t ) = C δ ( X , U ) x δ ( t ) + D δ ( X , U ) u δ ( t )
The terms A δ , B δ , C δ  and  D δ are the Jacobian matrices describing the nonlinear fuel cell system behavior at the operating point ( X , U ) = ( V F C , I F C ) .
The resulting fuel cell transfer function, which relates the incremental terminal voltage v F C δ ( s ) , to the incremental current i F C δ ( s ) supplied by the cell around the defined operating point, is given by Equation (14) based on the linearized model of Equations (12) and (13).
G F C δ ( s ) = v F C δ ( s ) i F C δ ( s ) = C F C δ   ( s I − A F C δ ) − 1 B F C δ + D F C δ = C F C δ B F C δ ( s − A F C δ ) + D F C δ
After obtaining the state-space representation and deriving the transfer function of the linearized system, fundamental conclusions regarding its dynamic behavior were drawn. First, the open-loop system is stable since its single pole is real and located in the left half-plane s = A F C δ < 0 .
It is observed that the transfer function contains an independent term D F C δ , indicating that the dynamic response to an input will exhibit two distinct components: a fast dynamic that instantaneously follows input changes, associated with the independent term, and a slow dynamic superimposed on the fast component, representing a delay associated with the first-order term in s .
After the transfer function was derived, the state matrices were implemented in MATLAB. The linearized model was verified by obtaining the static gain at an operating point that coincided with the same point on the slope of the polarization curve. The MPP presented in Figure 6 is a reference operating point for N = 28 , resulting in voltage, current, and power values of V f c = 12.46   V , I f c = 82.09   A , P f c = 1022.91   W . This point was determined under temperature conditions ( T = 65 ° ) , and partial pressures ( P H 2 = 3   a t m and P O 2 = 1   a t m ).
Figure 6. MPP obtained with simulation of the static model for a stack of N = 28 cells.
Finally, the dynamic response of the linearized model was compared with that of the nonlinear model under a change in current (Figure 7). The differences were minimal, demonstrating that the linearized model is suitable for analyzing small variations around the operating point, which is a critical aspect of DC/DC converter control.
Figure 7. Behavior of voltage to current perturbation between linearized and dynamic electrical models.

2.5. Discussion and Model Relevance

The developed mathematical model transcends a simple electrochemical representation, providing a comprehensive framework that couples the thermodynamic variables of the AEMFC with the dynamic requirements of power electronics. The obtained polarization and power curves (Figure 3 and Figure 6) not only allow for the identification of the maximum efficiency point but also define the safe operating limits for the boost converter, avoiding concentration regions where voltage instability could compromise the membrane.
Furthermore, the state-space representation and transfer function analysis (Section 2.4) are fundamental for the control strategy design. By identifying both slow and fast dynamic components, the need for cascaded control with anti-windup compensation is justified to mitigate load transients in a 0.75   k W motor. This system-level collaborative design approach ensures that the power conditioning, which is detailed in the following sections, is not an isolated block but an optimized extension of the actual capabilities of the anionic fuel cell stack.

3. DC/DC Power Converter

A DC/DC boost converter was designed in this study for the energy conditioning of the AEMFC. This converter acts as the critical interface between the chemical source and a 0.75 kW driving load, increasing the voltage that fluctuated between 12.45 and 17.9 V in the ohmic zone to a stable output of 48 V. The selection of this topology was based on its high efficiency for micromobility applications, supplying the required power of 0.75   kW to the DC motor under the demanding driving cycles of a light electric vehicle.

3.1. Energy Source Characterization: AEMFC Fuel Cell

The AEMFC operates in the ohmic region of its polarization curve, where the relationship between voltage and current is approximately linear, facilitating the implementation of control strategies. The technical characteristics of the stack, which were determined experimentally, are presented in Table 2.
Table 2. Technical specifications of the AEMFC fuel cell stack used in the prototype.
The operating zone is illustrated in the polarization curve (Figure 8), with a voltage range from V f c = 17.9 V to 12.45 V and a current range from I f c =  20.1 A to 82.2 A, corresponding to an output power of 360.5 W to 1022.9 W.
Figure 8. Polarization curve of the AEMFC fuel cell, highlighting the ohmic operating zone.
To complement this analysis, the stack power curve is included (Figure 9), showing the power behavior as a function of current, with a maximum peak of 1022.9 W at 82.2 A.
Figure 9. Power curve of the AEMFC fuel-cell stack.

3.2. Load Requirements: BLDC Motor

The selected load was a hub-type BLDC motor, which is widely used in electric mobility applications due to its high efficiency and robustness. The technical specifications are listed in Table 3.
Table 3. Technical specifications of the BLDC motor selected as the load.
The motor requires a constant supply voltage of 48 V, justifying the need for a step-up converter because the fuel cell output voltage is significantly lower.

3.3. Boost Converter Design

The boost converter was designed to operate in Continuous Conduction Mode (CCM), ensuring high efficiency and power delivery stability. Given that the behavior of switching converters under ideal conditions is extensively documented in the technical literature, this section omits such an analysis to focus exclusively on modeling the boost converter under real-world conditions. Parasitic losses of the components (series resistances of the inductor, capacitor, and semiconductors) were integrated, as these variables are decisive in guaranteeing the 48 V bus stability and overall system efficiency against the nonlinear dynamics of the AEMFC cell.

3.3.1. Analysis of the Boost Converter with Losses

The circuit analysis of the converter is based on a lumped-parameter model that integrates the ohmic losses associated with the series resistance of the inductor ( R L ), as illustrated in the schematic in Figure 10. This model allows for a rigorous approximation of the dynamic behavior of the system under real load conditions. Following the design assumptions of this study, ideal behavior was assumed for the capacitor and MOSFET switch, simplifying the analysis to focus on energy transfer in Continuous Conduction Mode (CCM). In this configuration, the control variable u entering the MOSFET gate is determined by the Pulse Width Modulation (PWM) signal, which establishes the duty cycle required for regulation. This strategy is essential for mitigating the current ripple in the AEMFC cell, ensuring that the energy supply to the 0.75 kW motor is stable and meets the requirements of the micromobility application.
Figure 10. Schematic of the boost converter with inductor internal resistance R L .
Based on the averaged loss model, expressions for efficiency ( η ) and the voltage transformation factor ( M ), are derived, considering the impact of the parasitic resistance R L . The real voltage transfer relationship is defined by Equation (15), and the energy efficiency of the converter is expressed by Equation (16):
M   = V M V f c   = 1 1   −   D ( 1   − R L i L V f c )
η = P o u t P i n = 1 − R L i L 2 V f c i L  
The term D represents the duty cycle and R M the equivalent load resistance of the motor. These expressions demonstrate that, unlike the ideal case, the transformation factor does not grow indefinitely with D , but presents an inflection point where ohmic losses predominate. This phenomenon is visualized in the next two subsections, where the efficiencies and output voltages are correlated with variations in the duty cycle, allowing the identification of the optimal operating range for the AEMFC system.
In addition to efficiency, a determining factor in converter design for fuel cell applications is the inductor current ripple ( Δ i L ) defined by Equation (17) and the capacitor voltage ripple ( Δ V c ) defined by Equation (18). In this study, the sizing of the passive components was performed under the criterion of maintaining the current ripple below 10% of the nominal current of the cell, thus mitigating fluctuations that could degrade the anionic membrane. Ripple analysis, whose mathematical formulation is derived from the voltage-second balance and charge balance conditions in the CCM, validates the selection of inductance and capacitance to ensure that the system operates within the stability margins required for the 0.75 kW motor.
Δ i L = V f c ∗ D T 2 L
Δ V c = Δ i L T 8 C

3.3.2. Component Selection

The selection of passive components and semiconductors was performed by balancing the available commercial specifications and design requirements derived from the ripple and efficiency analyses. Elements with low ohmic losses were prioritized to maximize the overall performance of the 1 kW system, ensuring that the selected inductance limits the current ripple to protect the integrity of the anionic membrane. The technical specifications of the final components that guarantee the operation of the 48 V bus for the 0.75 kW motor are listed in Table 4.
Table 4. Commercial components selected for the boost converter.

3.3.3. Operating Point

The nominal operating point for the control system design was established at a current of I = 47.5   A , voltage V f c = 15.78   V resulting in a duty cycle of D = 0.67 . This condition was strategically selected based on the polarization and power curves shown in Figure 11 and Figure 12, which define the maximum ohmic efficiency zone of the AEMFC stack. Operating at this point provides the necessary input voltage for the boost converter to deliver the 48 V required by the 0.75 kW motor, ensuring an optimal energy balance between electrochemical generation and load demand.
Figure 11. Operating point on polarization curve.
Figure 12. Operating point on power curve.
Under these design conditions and considering the impact of the inductor parasitic resistance ( R L ), the converter reaches an energy efficiency of 98% at the nominal operating point. This value, obtained following the loss analysis detailed in Section 3.3.1, correlates with the transformation factor behavior visualized in Figure 13, where the system stability against the power demand of the motor load is demonstrated.
Figure 13. Efficiency η and transformation factor M vs. duty cycle D .

3.4. Simulation Validation

PSIM simulations were performed to validate the design under ideal and lossy conditions (Figure 14, Figure 15 and Figure 16). The obtained ripples were Δ i L = 4.7 % y Δ V C = 6 % , which are acceptable for this application.
Figure 14. Circuit assembly with losses in PSIM.
Figure 15. Open-loop simulation results for the boost converter with losses regarding voltage ripple Δ V c .
Figure 16. Ideal boost converter simulation results for current ripple Δ I L .
To quantitatively evaluate the performance of the designed boost converter, a specific analysis of its energy efficiency and current/voltage ripple suppression was conducted across the entire operating range of the AEMFC cell. This analysis complements the previously presented simulation validation and establishes clear and comparable power-quality metrics.
The converter efficiency was evaluated by considering the main conduction losses in the MOSFET, diode, and inductor series resistance, as well as the switching losses. The results show that in Continuous Conduction Mode (CCM), the efficiency remains above 98% throughout the analyzed power range, reaching its peak near the maximum power point of the cell, as shown in Figure 13.
Regarding power quality, the inductor current ripple and output voltage ripple were quantified using PSIM simulations. The results indicate a current ripple of less than 5% and a voltage ripple within the ranges typically accepted in the literature for DC–DC converters applied to electric mobility systems and nonlinear sources. Table 5 summarizes the main performance and power quality parameters of the boost converter, confirming that the selection of the switching frequency and passive components enables effective ripple suppression.
Table 5. Performance and energy quality parameters of the boost converter.
Additionally, the response of the converter to load transients was evaluated, showing a fast recovery of the output voltage and the absence of sustained oscillations. This behavior ensures stable system operation and validates the suitability of the boost converter for integration with a nonlinear electrochemical source, such as an AEMFC.

3.5. Linearized Model for Control

Due to the nonlinear nature of the Boost converter, a small-signal linearized model was obtained around the nominal operating point ( V f c = 15.78   V , D = 0.67 ) . This procedure allows the derivation of the transfer functions required for the cascaded control strategy design, facilitating the stability analysis and tuning of the current and voltage loops. From the linearization of the state equations, the expressions describing the system dynamics against duty cycle variations are obtained as follows:
G v d ( s ) = Δ V M Δ D   = − 1.07 ×   10 6 ( s   −   1.07 ×   10 4 ) s 2   +   500 s   +   2.5 ×   10 6
G v i ( s ) = Δ V M Δ V f c = 2.86 × 10 3 ( s + 500 ) s 2 + 500 s + 2.5 × 10 6
The physical and operational parameters used to obtain the transfer functions and stability analysis are listed in Table 6. These values represent the nominal system conditions and result from the experimental and technical characterizations performed in previous stages.
Table 6. Operating parameters of the linearized model.

4. Control Design for the Boost Converter

A control system design for the boost converter was developed to guarantee a regulated output voltage of 48 V against input voltage variations from the AEMFC fuel cell. A closed-loop control scheme based on a cascaded structure was implemented, dynamically adjusting the duty cycle D via Pulse Width Modulation (PWM) to compensate for input fluctuations. The design focused on the nominal operating point ( V f c = 15.78   V , D = 0.67 ) , ensuring stability and rapid response to disturbances without relying on predefined static conditions. This dynamic approach addresses the nonlinear behavior of the fuel cell and the power requirements of the BLDC motor. The digital controller design was based on Bode plot analysis, employing an interactive tuning methodology with analytical and graphical techniques, supported by the MATLAB® R2023b SISOTOOL utility.

4.1. Converter Design Characteristics

The controller design considered the key dynamic specifications to ensure stability and component protection. These were defined in the time domain by evaluating the transient response of the system, which is typically represented by a second-order curve. The included characteristics were as follows:
  • Delay time ( t d ): The time required for the response to reach half of its final value for the first time.
  • Rise time ( t r ): The interval in which the response goes from 10% to 90% of its final value, adjusted according to the damping of the system.
  • Peak time ( t p ): The time to reach the first overshoot peak.
  • Maximum overshoot ( M p ): The maximum voltage excursion during transients, limited to 5% to protect components such as MOSFETs, diodes, and capacitors, although adjustable according to load tolerance.
  • Settling time ( t s ): The time for the response to remain within a range of 2% to 5% of the final value, critical during sudden variations.
  • Damping ratio ( ζ ): The relationship between M p and t r , with values between 0.4 and 0.8 to balance speed and stability.
  • Bandwidth ( ω b ): The frequency range where the gain drops to −3 dB, defining the dynamic capability of the system.
For the linear PI and PID controllers ω b and ζ , were prioritized, using the root locus pole-placement technique, verified with SISOTOOL to optimize dynamic performance.

4.2. Design Methodology

The adopted methodology, which was structured into four stages, combined theoretical modeling, computational tools, and experimental validation.
  • Linearized Model Analysis: The open-loop transfer function was developed from the state-space model, and its validity was analyzed using Bode plots and compared with experimental data.
  • Dynamic Parameter Specification: Requirements for cascaded control were defined. The inner (current) loop was designed with ζ = 0.707 and a phase margin >60° to compensate for MOSFET switching delays (≈150 ns). The outer (voltage) loop was operated with a bandwidth of 1/20 of the inner loop for decoupling.
  • Tuning in SISOTOOL: PID (inner loop) and PI (outer loop) controllers were tuned iteratively, combining manual pole/zero adjustment with automatic stability margin validation, considering parametric variations (±15% in L and C ).
  • Hybrid Validation: MATLAB-PSIM simulations and robust analyses were performed to correlate the parameters between both platforms under realistic conditions.

4.3. Linearized Model Analysis

Initial transfer function analysis showed non-minimum phase behavior between D and V M , due to a right-half-plane (RHP) zero, limiting direct controller design. The controlled variable was redefined as the inductor current ( i L ), reducing the system to first-order and eliminating the non-minimum phase. The new transfer functions are as follows:
G i d ( s ) = Δ i L Δ d   = V M L s   +   R L
G i i ( s ) = Δ i L Δ V i n = 1 L s + R L
The Bode plot (Figure 17) confirmed the validity of the model up to 10,000 Hz in magnitude and 500 Hz in phase, proposing a closed-loop bandwidth of 500 Hz for current control.
Figure 17. Bode plot of the linearized model for the current control.

4.3.1. Dynamic Parameter Specification

The linear representation of the system (Figure 18) models i L as the sum of contributions from D and V f c . The controller design was based on a closed-loop feedback (Figure 19), with ω b = 500 Hz and ζ = 0.707.
Figure 18. Linear representation of the model based on the transfer functions.
Figure 19. Schematic of closed-loop feedback loop.

4.3.2. PID Controller Tuning (Inner Loop)

PID tuning for the inner loop was performed in SISOTOOL, adjusting ω b and ζ through proportional, integral, and derivative control (Figure 20). After iteration, a stable response without significant oscillations was obtained (Figure 21), and the transfer function was exported for the PSIM simulation.
Figure 20. Circuit representation of the PID controller simulated in PSIM ( G c i ) .
Figure 21. Current control response for I L against a reference current I r e f .

4.3.3. PID Controller Validation

PSIM validation (Figure 22) showed precise tracking of i L against reference steps and V f c disturbances (Figure 23 and Figure 24). Bode analysis (Figure 25) confirmed adequate performance up to 1000 Hz.
Figure 22. Current control response for I L against a − 5   A step in reference current I r e f .
Figure 23. Current control response for I L (green line) against a − 5   A step in reference current ( I r e f ) and an input voltage disturbance ( V f c ) .
Figure 24. Current control response for ( I L ) against a − 5   A step in reference current ( I r e f ) at 50   m s , an input voltage disturbance ( V f c ) at 55   m s , and parallel connection of 9   Ω and 6   Ω resistors at 65   m s and 75   m s .
Figure 25. Bode plot of the transfer functions for current control.

4.3.4. Cascaded PI Control Design (Outer Loop)

Due to the non-minimum phase behavior in the V M , transfer function, a cascaded control was implemented. The inner loop imposed a current source dynamic on i L , hereby simplifying the outer voltage loop (Figure 26). The transfer function for the outer loop is:
G v ( s ) = Δ V M Δ i r e f   = 1   −   D C s   + 1 R
Figure 26. Cascaded control diagram for the boost converter.
The PI controller was tuned in SISOTOOL with ω b = 5   K H z and ζ = 0.707 , validating its performance in PSIM (Figure 26, Figure 27, Figure 28, Figure 29, Figure 30 and Figure 31).
Figure 27. Response of current control ( I L ) and voltage control ( V C ) to a reference current ( I r e f ) and reference voltage ( V r e f ) .
Figure 28. Response of current control ( I L ) and voltage control ( V C ) to a reference current disturbance I r e f at 20   m s .
Figure 29. Response of current control ( I L ) and voltage control ( V C ) to a reference current disturbance I r e f at 20   m s and an input voltage disturbance V f c of 2   V .
Figure 30. Response of current control ( I L ) and voltage control ( V C ) to a reference current disturbance I r e f at 20   m s , an input voltage disturbance V f c of 2   V and variable load conditions provided by the parallel connection of two resistors 9   Ω at 35   m s and 6   Ω at 35   m s .
Figure 31. Behavior of ( V f c ) and ( I m ) under a reference current disturbance I r e f at 20   m s , una perturbación de en el voltaje de entrada V f c de 2   V an input voltage disturbance 9   Ω at 35   m s and 6   Ω at 35   m s .
The simulations validated the satisfactory performance of the cascaded control system. The implemented PI and PID controllers demonstrate the capability to effectively regulate the Boost converter against significant disturbances in input voltage ( V f c ) , variations in reference current ( I r e f ) and changes in load ( R M ) . The system response to these disturbances was characterized by stability and precision, confirming the validity of the design and its fulfillment of the objective of maintaining a regulated output voltage.

5. Results

For the fuel cell power conditioning, a Boost converter was selected due to its capability to step up the input voltage ( V f c ) from 15.78   V to the 48   V required at the operating point of the system. The selection of this operating point was based on the specifications of the brushless motor of the electric bicycle, considering the voltage and power requirements in a mobility application scenario. Consequently, a detailed analysis of the mathematical model of the boost converter was performed, emphasizing design parameters that allowed for the selection of components such as the MOSFET, inductor, capacitor, and diode (Table 4) for the operating points defined by the cell voltage and the power demand of the motor. In addition, differential equations describing the converter dynamics were derived to develop a linearized model.
The linearized model of the converter served as a fundamental tool for frequency-domain analysis. This analysis determined the optimal operating bandwidth (detailed in Table 7), a critical parameter for the robust design of the cascaded control strategy implemented for output voltage regulation ( V M ) (Figure 26). The information obtained from the frequency analysis ensured the adequate dynamic performance and stability of the converter under various load conditions and disturbances.
Table 7. Bandwidth values for the designed controller.
The controller design methodology was based on the Bode graphical method and was implemented using the MATLAB Sisotool utility. This platform provides an interactive environment for manipulating the open-loop transfer function, allowing for the iterative placement of the poles and zeros of the compensator. The objective of this manipulation was to satisfy the previously established design specifications, particularly the desired bandwidth and damping factor required to ensure an adequate dynamic response. Through this process, the transfer functions of the controllers designed for the nominal operating point of the system were obtained. Subsequently, these transfer functions were implemented in PSIM circuit simulations, where the control robustness was evaluated against typical operational disturbances, as shown in Figure 32.
Figure 32. Current control ( I L ) and voltage control ( V C ) response to disturbances in load ( R M ) reference current ( I r e f ) and input voltage ( V f c ) .
Simulation analysis revealed that the cascaded control strategy, which implements PI and PID regulators in their respective loops, demonstrated a satisfactory dynamic response to various disturbances and system parametric variations. Specifically, an adequate capability to maintain the power output within the desired limits against transients and changes in the system parameters was observed. The validation of the control strategy through PSIM simulations, particularly with the PID regulator in the inner loop and PI in the outer loop, confirms its effectiveness in guaranteeing the robust dynamic behavior of the converter.
The converter and designed control strategy were validated by implementing a physical boost converter prototype, which was dimensioned according to the technical specifications consolidated in the previous sections. The experimental setup, as shown in Figure 33, integrates an Arduino Nano microcontroller for peripheral management and Pulse Width Modulation (PWM) signal generation. This system includes the automation of a solenoid valve for hydrogen supply and a thermal management system using forced ventilation. Data acquisition was carried out using current sensors in the inductor and the load, employing 1   Ω for control loop feedback. For dynamic tests, the input voltage was stabilized at 15.78   V using a regulated source, while the load consisted of an electric bicycle motor with a pedal accelerator, allowing for validation of the system response to real load disturbances in a mobility environment.
Figure 33. Experimental setup of the power conditioning system with boost converter and dynamic load testing.
The results obtained from the experimental testing confirmed the correct operation of the proposed system and validated the effectiveness of the implemented control strategy. The stability of the output voltage, even under dynamic load variations, demonstrates the capability of the converter and control scheme to respond robustly and safely, protecting the fuel cell and ensuring a continuous supply to the motor. These findings provide evidence of the fulfillment of the stated objectives and establish a solid foundation for future real-scale applications and developments, consolidating the technical feasibility of the proposed prototype.

6. Discussion

This section analyzes the results obtained in the development of the power control system for a hydrogen-fed AEMFC, interpreting their relevance in the context of electric mobility applications, such as powering an electric bicycle brushless motor. The implications of the findings and the limitations of the study are discussed, comparing the results with previous studies and integrating contributions from Section 2, Section 3 and Section 4 to provide a holistic view of the project. Finally, future work perspectives aligned with the identified needs are discussed.

6.1. AEMFC Modeling and Characterization

The selection of the mathematical model for the AEMFC cell was a crucial step in the control system design. Characterization based on constructive parameters (Table 1) allowed for the generation of accurate polarization and power curves (Figure 3 and Figure 6), identifying the Maximum Power Point (MPP) at 0.6 V per cell, with a total power of 1 kW for the 28-cell stack. This result is consistent with the AEMFC models reported in the literature, where the ohmic zone defines the optimal operating range to avoid significant activation or concentration losses.
The linearized model derived around the MPP showed high fidelity in representing small perturbations, validating its utility for designing advanced control strategies. However, the lack of a physical cell due to manufacturing delays limited the experimental validation of the model, representing a significant restriction. This challenge underscores the need to integrate simulations into real-world testing.
The identification of the safe operating range within the ohmic zone (Figure 8) represents a key advancement, as it ensures cell protection against overcurrent (a critical issue in high-power applications). Compared to the results in Section 2, where the characteristic curves of similar cells were analyzed, the operating range defined in this study was narrower. This suggests a higher sensitivity to variations in the operating conditions, such as temperature and reactant pressure. This finding highlights the importance of implementing robust control systems to maintain operational stability, which is addressed in the following sections.

6.2. Boost Converter Design and Performance

The design of the boost converter, detailed in Section 3, was based on a comprehensive analysis of the mathematical model to ensure an efficiency exceeding 98% in continuous conduction mode. The component selection (Table 4) was aligned with the load requirements of a 750 W brushless motor, and PSIM simulations confirmed a current ripple of 4.7% and a voltage ripple of 6%, both within the specified limits.
The linearized model of the converter, described by the transfer functions and Equations (19) and (20), enabled a frequency-domain analysis that was fundamental to the cascade control design. This approach is consistent with the methods presented in Section 3, where similar dynamic models were derived to optimize the converter performance under disturbances. The high efficiency achieved (>98%) exceeds the values reported in previous studies for boost converters in fuel cell applications, which typically range between 95% and 97% [23,25].
The integration of the startup and management system, governed by an Arduino Nano microcontroller, represents a significant advancement in coordinating critical peripherals. This architecture allows for the synchronized activation of thermal management fans and hydrogen supply solenoid valves, optimizing the cell startup sequence to prevent premature degradation. This integrated management approach is essential for ensuring operational safety and efficiency under dynamic load variations. However, while the Arduino Nano platform is suitable for this 1 kW prototype, its implementation in high-power applications would require a transition toward industrial control architectures or DSPs to ensure the scalability and robustness demanded in heavy-duty mobility environments

6.3. Cascaded Control and System Robustness

The cascaded control strategy, featuring an inner PID loop and an outer PI loop (Figure 32), demonstrated a robust dynamic response to disturbances, as evidenced by PSIM simulations (Figure 33). Tuning based on the Bode method, implemented via MATLAB SISOTOOL, achieved bandwidths of 500 Hz and 5 kHz for the inner and outer loops, respectively, ensuring stability and precision in output voltage regulation.
These results are consistent with the control analyses presented in Section 4, where the regulation strategies for fuel-cell-based power systems were explored. The robustness observed against parametric perturbations and transients validates the selection of cascaded control, which is an approach widely adopted in power electronics applications. However, the lack of experimental testing with the control implemented in the prototype—due to the absence of the cell and the motor—limits the evaluation of its performance under real-world conditions. This challenge highlights the importance of complementing simulations with physical testing, as recommended in the literature.
A comparison with previous studies revealed that the selected bandwidth (500 Hz for the inner loop) was suitable for low-to-medium frequency applications but might require adjustments for highly dynamic loads, such as those encountered by electric vehicles in urban driving conditions.

6.4. Prototype Validation and Construction Limitations

The physical implementation of the prototype on Bakelite confirmed the functional feasibility of the boost topology for the required voltage step-up (15.78 to 48 V). However, performance analysis suggests that the artisanal manufacturing technique and chemical etching employed introduce parasitic inductances and contact resistances that are not present in an ideal model. While these variations are tolerable for proof of concept and validation of the control strategy, for a technology transfer phase or commercial application, it is imperative to migrate toward industrial PCB manufacturing processes with impedance control.
Furthermore, the integration of the control logic into an Arduino Nano proved to be a cost-effective solution for peripheral management and the initial control loop. However, from a scalability perspective, the processing cycle time could represent a limitation in higher-power systems or those with higher switching frequencies. Consistent with the technical literature, future developments should be oriented toward the use of Digital Signal Processors (DSPs) or FPGAs, allowing for the parallel execution of more complex control algorithms and greater robustness against the electromagnetic noise inherent in electric mobility systems.

6.5. Future Work and Perspectives

The findings of this study establish a technical foundation for several future developments. As an immediate priority, the integral validation of the cascaded control loop using the AEMFC stack under real dynamic load profiles was identified. These tests, projected for execution once the physical cell is available, will allow for the evaluation of system robustness against mass transport phenomena and water management, which are critical for operation in urban-mobility environments.
In the field of control, the optimization of PI and PID loops through advanced techniques, such as robust or adaptive control, represents an opportunity to improve the transient response and overall efficiency. This approach mitigates the residual nonlinearities identified in the model and brings the converter performance closer to the theoretical efficiency limit (>99%) reported in cutting-edge studies. Additionally, the need to integrate overcurrent and overvoltage protection circuits is envisioned to guarantee the integrity of graphene membranes against unforeseen failures.
Finally, the transition toward an autonomous and commercially viable system requires a multidisciplinary approach that transcends laboratory prototypes. This includes the miniaturization of the electronic design through industrial manufacturing techniques and incorporation of more complex energy management algorithms. Thus, the present study serves as a catalyst for future innovations in the field of hydrogen-based sustainable mobility, facilitating the scaling of clean technologies in regions with demanding topographies.

7. Conclusions

This study validated the design of a power conditioning and control system for a 1 kW Anion Exchange Membrane Fuel Cell (AEMFC), which was optimized to power a 0.75 kW brushless motor. Through an interdisciplinary approach integrating electrochemical modeling, power electronics, and robust control, the following milestones were achieved:
  • Modeling and Characterization: The mathematical model, adjusted to the parameters of the GRIEQUI research group, demonstrated high fidelity in the ohmic zone, identifying the optimal operating point at 0.6 V per cell. This established a safe operating regime that maximized the lifespan of the 28-cell stack, preventing overcurrent conditions that would degrade the graphene membrane.
  • Energy Efficiency: The designed boost converter achieved an efficiency exceeding 98% in Continuous Conduction Mode (CCM). Compliance with the design criteria was reflected in a current ripple of 4.7% and a voltage ripple of 6%, values that guarantee stable 48 V power delivery to the driving load while minimizing the thermal stress on passive components.
  • Control and Stability: The cascaded control strategy (inner PID and outer PI), tuned using the frequency response method, demonstrated a robust dynamic response. The achieved bandwidth (5 kHz in the current loop) ensures effective disturbance mitigation during load variations in micromobility applications, maintaining DC bus stability across the entire operating range.
  • Projection and Scalability: The results obtained through simulations and preliminary prototype validation provide a solid foundation for the final system integration. Although the use of low-cost platforms, such as the Arduino Nano, is viable for proof-of-concept testing, the transition toward Digital Signal Processing (DSP) architectures is identified as the path to enhance efficiency through soft-switching techniques and adaptive control.
  • Final Synthesis: In conclusion, this study demonstrates that the integration of AEMFC cells with high-efficiency power converters represents a robust technological alternative for sustainable mobility. The methodology presented herein not only meets the technical power requirements but also offers a scalable control architecture for the development of hydrogen-based electric vehicles in complex urban environments.

Author Contributions

Conceptualization, investigation, methodology, software, formal analysis, writing—review and editing, M.A.B.Á., F.E.H. and J.E.C.-B. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Acknowledgments

The authors thank the GRIEQUI research group for providing the data for this research. The work of Fredy Hoyos and John E. Candelo-Becerra was supported by the Universidad Nacional de Colombia, Sede Medellín.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

SymbolDescriptionUnit
Fuel Cell (AEMFC)
V f c Fuel cell output voltageV
I f c Fuel cell stack currentA
P m a x Maximum power point (MPP)W
V c e l l Open-circuit voltageV
V a c t Activation overpotentialV
V o h m Ohmic overpotentialV
V c o n c Concentration overpotentialV
ζ i Semi-empirical coefficients (i = 1 to 4)-
Boost Converter
V f c Input voltage (from FC)V
V M Output voltage (at the motor)V
L Inductor inductanceH
C Output capacitanceF
f Switching frequencyHz
D Duty cycle-
R L Inductor internal resistanceΩ
Δ i L Inductor current rippleA or %
Δ V C Output voltage rippleV or %
Control Strategy
G c v Outer loop transfer function (Voltage)-
G c i Inner loop transfer function (Current)-
I r e f Reference currentA
B W c l System bandwidthHz
Acronyms
AEMFCAnion Exchange Membrane Fuel Cell-
PEMFCProton Exchange Membrane Fuel Cell-
CCMContinuous Conduction Mode-
ORROxygen Reduction Reaction-
PGMPlatinum Group Metals-
PWMPulse Width Modulation-
BLDCBrushless Direct Current (Motor)-

References

  1. Ferriday, T.B.; Middleton, P.H. Alkaline fuel cell technology—A review. Int. J. Hydrogen Energy 2021, 46, 18489–18510. [Google Scholar] [CrossRef] [Scilit]
  2. Monteiro, E.; Brito, P.S.D. Hydrogen supply chain: Current status and prospects. Energy Storage 2023, 5, e466. [Google Scholar] [CrossRef] [Scilit]
  3. Chen, H.; Tao, R.; Bang, K.-T.; Shao, M.; Kim, Y. Anion exchange membranes for fuel cells: State-of-the-art and perspectives. Adv. Energy Mater. 2022, 12, 2200934. [Google Scholar] [CrossRef] [Scilit]
  4. Hameed, A.S.; Munusamy, S.; Gokulapriyan, R.; Yoo, D.J. Comprehensive review of anion exchange membrane with ether and ether-free backbone. ACS Appl. Polym. Mater. 2024, 6, 12341–12361. [Google Scholar] [CrossRef] [Scilit]
  5. Hyun, J.; Kim, H.-T. Powering the hydrogen future: Current status and challenges of anion exchange membrane fuel cells. Energy Environ. Sci. 2023, 16, 5633–5662. [Google Scholar] [CrossRef] [Scilit]
  6. Mustain, W.E.; Chatenet, M.; Page, M.; Kim, Y.S. Durability challenges of anion exchange membrane fuel cells. Energy Environ. Sci. 2020, 13, 2805–2838. [Google Scholar] [CrossRef] [Scilit]
  7. Dekel, D.R. Review of cell performance in anion exchange membrane fuel cells. J. Power Sources 2018, 375, 158–169. [Google Scholar] [CrossRef] [Scilit]
  8. Hossen, M.; Hasan, S.; Sardar, R.I.; bin Haider, J.; Mottakin, K.; Tammeveski, K.; Atanassov, P. State-of-the-art and developmental trends in platinum group metal-free cathode catalyst for anion exchange membrane fuel cell (AEMFC). Appl. Catal. B 2023, 325, 121733. [Google Scholar] [CrossRef] [Scilit]
  9. Duong, P.A.; Ryu, B.R.; Jung, J.; Kang, H. A comprehensive review of the establishment of safety zones and quantitative risk analysis during ship-to-ship LNG bunkering. Energies 2024, 17, 512. [Google Scholar] [CrossRef] [Scilit]
  10. Hamada, A.T.; Orhan, M.F.; Kannan, A.M. Alkaline fuel cells: Status and prospects. Energy Rep. 2023, 9, 6396–6418. [Google Scholar] [CrossRef] [Scilit]
  11. Ma, X.; Zhao, X.; Fu, L.; Qiang, Y.; Bai, Q. Recent advances in modification strategies of anion exchange membranes for AEMFCs and AEMWEs. Int. J. Hydrogen Energy 2026, 214, 153748. [Google Scholar] [CrossRef] [Scilit]
  12. Günaydın, Ö.F.; Topçu, S.; Aksoy, A. Hydrogen fuel cell vehicles: Overview and current status of hydrogen mobility. Int. J. Hydrogen Energy 2025, 142, 918–936. [Google Scholar] [CrossRef] [Scilit]
  13. Sebbani, I.; Ettouhami, M.K.; Boulakhbar, M. Fuel cells: A technical, environmental, and economic outlook. Clean. Energy Syst. 2025, 10, 100168. [Google Scholar] [CrossRef] [Scilit]
  14. Singh, D. A review on hydrogen powered fuel cell vehicles: The present scenario and prospects for the future. Curr. Sustain. Energy Rep. 2025, 12, 24. [Google Scholar] [CrossRef] [Scilit]
  15. Ponnada, S. Machine learning in next-generation AEM fuel cells: A systematic review. RSC Adv. 2026, 16, 7863–7910. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Andrade, P.; Alcaso, A.N.; Bento, F.; Cardoso, A.J.M. Buck-boost DC-DC converters for fuel cell applications in DC microgrids—State-of-the-art. Electronics 2022, 11, 3941. [Google Scholar] [CrossRef] [Scilit]
  17. Gkizas, G. Optimal robust control of a Cascaded DC–DC boost converter. Control Eng. Pract. 2021, 107, 104700. [Google Scholar] [CrossRef] [Scilit]
  18. Saadi, R.; Hammoudi, M.Y.; Salah, O.; Laadjal, K.; Cardoso, A.J.M. A two-degree-of-freedom PID integral super-twisting controller based on atom search optimizer applied to DC-DC interleaved converters for fuel cell applications. Electronics 2023, 12, 4113. [Google Scholar] [CrossRef] [Scilit]
  19. Mitra, U.; Arya, A.; Gupta, S. DC microgrid integration of an optimized proton exchange membrane fuel cell utilizing a cost-effective clamping boost converter. J. Indian Chem. Soc. 2026, 103, 102401. [Google Scholar] [CrossRef] [Scilit]
  20. Bae, J.E.; Kim, K.H.; Chu, S.C.; Heo, J.; Lim, S.; Sung, S.W. Development of an antiwindup technique for a cascade control system. ACS Omega 2020, 5, 32597–32607. [Google Scholar] [CrossRef] [Scilit]
  21. Jia, Y.; Zhang, R.; Lv, X.; Zhang, T.; Fan, Z. Research on temperature control of fuel-cell cooling system based on variable domain fuzzy PID. Processes 2022, 10, 534. [Google Scholar] [CrossRef] [Scilit]
  22. Maaruf, M.; Babangida, A.; Ahmed, I.; Khalid, M.; Szemes, P.T. Advanced control strategies for fuel cell hybrid electric vehicles—A review. Energy Convers. Manag. X 2025, 28, 101354. [Google Scholar] [CrossRef] [Scilit]
  23. Manzano, F.S. Prototipo Experimental de Sistema Híbrido Basado en Pila de Combustible Diseño. Doctoral Thesis, Universidad de Huelva, Huelva, Spain, 2009. [Google Scholar]
  24. Toledo, L.E.N. Simulación Molecular de la Doble Capa Eléctrica en la Interfase Catódica Pt/O2/H2O Para Celdas de Combustible de Hidrógeno. Master’s Thesis, Universidad Nacional de Colombia, Bogotá, Colombia, 2020. [Google Scholar]
  25. Mann, R.F.; Amphlett, J.C.; Hooper, M.A.I.; Jensen, H.M.; Peppley, B.A.; Roberge, P.R. Development and application of a generalised steady-state electrochemical model for a PEM fuel cell. J. Power Sources 2000, 86, 173–180. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.