Skip to Content
  • Article
  • Open Access

23 November 2026

21 Pages

Koopman-Based State Observer for a Coupled Three-Tank System

,
and
Facultad de Ingeniería, Universidad Distrital Francisco José de Caldas, Bogotá 110231, Colombia
*
Author to whom correspondence should be addressed.
Appl. Syst. Innov.2026, 9(12), 248;https://doi.org/10.3390/asi9120248 
(registering DOI)
This article belongs to the Section Control and Systems Engineering

Abstract

This paper presents a Koopman-based Luenberger-type observer that reconstructs the unmeasured level of a partially observed three-tank hydraulic system. The observer operates natively in an eight-dimensional space of physics-informed observables identified via Extended Dynamic Mode Decomposition (EDMD). Its feedback gain is synthesized offline through the discrete algebraic Riccati equation (DARE), and the ultimate boundedness of the estimation error is established analytically in a weighted Lyapunov norm. The observer is benchmarked in a closed loop against an Extended Kalman Filter (EKF) under an identical model predictive controller, over five independent runs per observer (ten in total) on a physical plant instrumented with an independent ground-truth level sensor on the unmeasured tank. Under the as-run experimental gains, the Koopman observer reduces the observation RMSE against ground truth by 19.3% (1.139±0.057 vs. 1.412±0.064 cm), whereas the physical tracking error of the plant against the setpoint shows no statistically detectable difference (0.804±0.031 vs. 0.799±0.011 cm, Welch p=0.74). An offline leave-one-run-out cross-validated replay of the recorded telemetry indicates that this initial observation advantage is largely attributable to the specific EKF noise-covariance ratios utilized in the live experiments. When both observers are tuned via cross-validation, they achieve comparable estimation accuracy (0.655±0.023 cm for Koopman vs. 0.600±0.020 cm for EKF). A predictor-only baseline confirms that the output injection actively rejects a deliberately injected +2.0 cm offset, decaying it to 10% within approximately 7 s in the replay (12 s under noise-free propagation), while the pure predictor drifts to >5.5 cm RMSE. Isolated algorithmic profiling confirms that the full recursion of an optimized EKF (0.087 ms with the AD Jacobian, against 0.038 ms for the Jacobian evaluation alone) is comparable to the linear Koopman update (0.025 ms); both are vastly overshadowed by the non-convex predictive control optimization, which alone requires 14.50 ms on average (P99 19.90 ms) and yields a complete Koopman observer-plus-controller pipeline of 14.53 ms on average (P99 19.96 ms; the corresponding EKF pipeline is 15.03 ms with the finite-difference Jacobian and 14.59 ms with the algorithmic-differentiation Jacobian), negligible against the 2.1 s hardware sampling period. The Koopman observer therefore delivers EKF-grade precision with a linear, time-invariant structure, eliminating real-time Jacobians while providing an ultimate-boundedness guarantee for the lifted estimation error of the identified model.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.