Highlights
What are the main findings?
- The circuit model considering multiple switch states is developed for the wireless charging system of drones based on a D3-type transmitter. The characteristics analysis is conducted on the three excitation modes present in the reconfigurable D3-type transmitter.
- The dual-coil excitation mode is selected after comparative analysis, taking into account factors such as the number of excitation coils, the minimum mutual inductance, the mutual inductance fluctuation, and the receiving-excitation area ratio. The transmitter reconfiguration method based on one detection sensor of DC current and one relay is proposed to enhance the misalignment tolerance and the receiving-excitation area ratio.
What are the implications of the main findings?
- The system architecture and unified modeling analysis method proposed in this article provide new ideas for optimizing the anti-offset performance of unmanned aerial vehicle wireless charging systems.
- The usage of reconstruction switches and positioning detection sensors is reduced through the proposed transmission coil structure and reconstruction method, while taking into account anti-offset, receiver excitation ratio, and hardware cost.
Abstract
Wireless charging for drones is significant for solving problems such as the frequent manual plugging and unplugging of cables. A large number of densely packed transmitting coils and fully independent on-off control can precisely track the receiver with random access location. To balance the excitation area of the transmitter, additional hardware cost, and receiving voltage fluctuation, the wireless charging system of drones based on a D3-type transmitter is proposed in this article. The circuit model considering states of multiple switches is developed for three excitation modes. The dual-coil excitation mode is selected after comparative analysis. The transmitter reconfiguration method with low hardware cost and high receiving-excitation area ratio is proposed based on one detection sensor of DC current and one relay furtherly. Finally, an experimental prototype is built to verify the theoretical analysis and proposed method. When the output voltage fluctuation is limited to ±10%, the ratios of the maximum misalignment value in the x-axis and y-axis directions to the side length of the receiver reach 66.7% and 46.7%, respectively. The receiving-excitation area ratio of 37.5% is achieved, significantly reducing the excitation area not covered by the receiver. The maximum receiving power is 289.44 W, while the DC-DC efficiency exceeds 87.05%.
1. Introduction
Drones have been utilized in fields such as industrial inspection, express transportation, agriculture, and construction. However, the commonly used contact charging method currently has drawbacks, including wear and tear, electric shock, difficulty in achieving unmanned operation, and difficulty in adapting to all-weather working environments. At present, most commercial or industrial drones are powered by manual battery replacement and manual plugging and unplugging for charging. As power replenishment still relies on human intervention, complete and comprehensive unmanned operation still needs to be achieved through innovative technological means. Wireless power transmission (WPT) technology helps electrical devices break free from the constraints of connecting cables or contacting sliding rails, significantly enhancing the safety, flexibility, and user experience of power supply [1]. Currently, WPT based on the principle of magnetic field coupling [2] has broad application prospects in various fields such as consumer electronics, drones [3], robots [4], implantable medical devices [5], electric vehicles [6], underwater equipment [7], smart sensors [8], and rail transit [9]. The wireless power supply is of great value for achieving intelligent power replenishment of drones.
In magnetic coupling WPT systems, the position misalignment of mobile loads such as drones often leads to a drop in load voltage, system power, and efficiency [10]. To address this issue, the closed-loop control of DC conversion modules at the transmitting or receiving sides is employed to achieve stable voltage and power at the drone side within a certain range of position deviation [11,12,13]. Some studies enhance the stability of receiving power by proposing schemes such as optimizing compensation circuit parameters [14], controlling compensation circuits [15,16], and switching between multiple compensation circuit topologies [17]. These methods not only require additional energy conversion links or compensation circuits, but also significantly increase the difficulty of power stability regulation when the magnetic coupling of the transmitting and drone sides varies greatly. Compared with the aforementioned methods, magnetic coupling mechanism design is the primary way to improve the system’s adaptability to random positions of the receiver.
To enhance the coupling stability under the misalignment of the transceivers and ensure the stability of the receiving side under the random position of drones, some studies have proposed the use of relatively larger transmitting coils [18,19,20]. A wider area of stable mutual inductance is achieved through optimal design to allow for a larger range of position misalignment of the receiver. A magnetic coupling mechanism based on the combination of multiple circular coils to improve the anti-deviation performance of the wireless charging system is proposed in [21]. A scheme to enhance the load stability of random receiving position based on multiple annular-sector-shaped coils and parameter optimization is investigated in [3]. The optimization method for non-uniformly spaced square transmitting coils based on genetic algorithms to improve the misalignment tolerance performance of the circular receiver is studied in [22]. The large transmitter and small receiver structure with a relay coil is proposed to achieve good adaptability to the receiver position in [23]. These methods use only a single inverter at the transmitting side, resulting in lower hardware complexity and cost. However, due to the asymmetric design of transmitter and receiver, most areas of the transmitter not covered by the receiver are still kept excited, causing additional losses, electromagnetic field and heating risk.
Related research combines optimized design of multiple transmitting coils, positioning of drones, and on-off control of distributed multiple coils to achieve stable energy transmission under random receiving positions of drones. The transmitting coils not covered by the receiver can be switched off to reduce system loss and heat at the same time. The system topology design and switching control method based on multiple coils and multiple compensation circuit components is proposed to achieve compatibility with various types of receivers and stable output voltage under a 360-degree rotational offset in [24]. In [25], the multiple transmitting coil array is employed with independently matched inverters and compensation circuits, while the receiver is made by vertically winding litz wire around ferrite. The control of multiple inverters ensures efficient energy transmission in the entire plane. In [26], seven overlapping coils are used to form the transmitting array, in which each coil is controlled by an independent switch to access the corresponding compensation circuit. Seven alternating current (AC) current sensors are employed at the front end of the independent compensation circuits to detect high-frequency AC current and determine the optimal excited transmitting coil. In [27], a multi-phase parallel inverter combined with multiple relays at the transmitting side is utilized to flexibly control multiple transmitting coils with independent compensation circuits. The issues of misalignment tolerance, receiver excitation ratio, and hardware cost need to be considered comprehensively.
The transmitting side adopts an integrated coil design to achieve a wide range of uniform magnetic field coupling area, which has the advantages of low system complexity and simple regulation. However, it cannot flexibly turn off the excitation of most transmitter areas not covered by the receiver. Although the transmitting side uses a reconfigurable coil array, which can achieve magnetic field regulation and precise excitation in different zones, the extensive use of detection sensors and switches makes the system control complex and costly. It also leads to problems of compensation parameter re-matching under coil array reconfiguration, which is unacceptable in some situations. In addition, new receiver positioning schemes for supporting the reconfiguration control of the transmitting coil array need to be proposed to reduce parameter requirements, complexity, and cost of hardware, including sensors and switches. To address the above issues, the transmitter reconfiguration method with low hardware cost and high receiving-excitation area ratio (ratio of the receiver area to the energized area of the transmitter) for a wireless charging system of drones based on a reconfigurable D3-type transmitter is proposed. The main contributions of this article are as follows:
- (1)
- The wireless charging system of drones based on the reconfigurable D3-type transmitter is proposed. A unified system circuit model considering multiple reconfiguration switch states is developed for three excitation modes.
- (2)
- The characteristics analysis is conducted on the three excitation modes present in the reconfigurable D3-type transmitter. The dual-coil excitation mode is selected after comparative analysis, taking into account factors such as the number of excitation coils, the minimum mutual inductance, the mutual inductance fluctuation, and the receiving-excitation area ratio.
- (3)
- The relationship between the inverter input DC current and load output voltage gain is established. The design of the reconfigurable D3-type transmitter topology is simplified based on one switch. The transmitter reconfiguration method based on one detection sensor of DC current and one relay is proposed.
- (4)
- The experimental prototype for the wireless charging system of drones is built. Experimental results show that the ratios of the maximum misalignment value in the X-axis and Y-axis directions to the side length of the receiver reach 66.7% and 46.7%, respectively. The receiving-excitation area ratio of 37.5% is achieved, significantly reducing the excitation area not covered by the receiver. It takes into account the hardware cost, control complexity, adaptability to receiving positions and the receiving-excitation area ratio.
The rest of this article is organized as follows. In Section 2, an introduction to the wireless charging system of drones based on the reconfigurable D3-type transmitter is presented. The unified system circuit model is developed. In Section 3, the characteristics analysis is conducted on the three excitation modes. The transmitter reconfiguration method is proposed. The experimental verifications are carried out in Section 4. The conclusion is summarized in Section 5.
2. Introduction and Circuit Modeling for Wireless Charging System of Drones
2.1. System Introduction
In order to improve the adaptability of drone wireless charging systems to different load positions, two commonly used schemes based on magnetic coupling mechanisms are system topology based on large transmitting coils and single inverters, and system topology based on multiple transmitting coil arrays, multiple inverters and multiple compensation circuits, as shown in Figure 1a and Figure 1b, respectively. In Figure 1a, the system uses one coil with a larger area (or a fixed series of multiple coil arrays) as the transmitting side, which can improve the flexibility of load position. However, the entire transmitter needs to be continuously excited, causing additional losses and electromagnetic field and heating risk. As shown in Figure 1b, each transmitting coil in the system is independently connected to a separate inverter. By disconnecting some of the transmitting coils, the current flowing through can be reduced to zero, which can significantly reduce the loss and heat in unnecessary areas of the coils. Although precise control of the excitation area at the transmitting side can be easily achieved, it relies heavily on hardware such as inverters, compensation circuits, and detection sensors.
Figure 1.
Schematic of system structure. (a) Fixed transmitter with one inverter and one compensation circuit. (b) Transmitter with multiple inverters and multiple compensation circuits. (c) Reconfigurable transmitter with switches.
To balance the hardware cost, control complexity, adaptability to receiver position and the receiving-excitation area ratio, the system topology is proposed as shown in Figure 1c. The transmitting side adopts one inverter, one compensation circuit, and the reconfigurable D3-type transmitter consists of three D-shaped coils through control switches (S1, S2 and S3). Both the transmitter and the receiver are single planar spiral coil structures. The transmitter is not the overlapping coil structure. The advantage is to minimize the thickness of the transmitter as much as possible. LCC (inductance-capacitor-capacitor) compensation is applied on the transmitting side. In a wireless power transmission system, there are several typical compensation topologies, such as series-series, series-parallel, parallel-series, parallel-parallel, LCC-series, LCC-LCC, etc. Series-series, LCC-series and LCC-LCC are the commonly used compensation topologies at present. Different compensation topologies exhibit distinct system characteristics. Compared with series-series topology, LCC-series topology can realize that the current of the primary coil is constant. When the load side is removed, the system with LCC topology on the primary side does not suffer from overcurrent. Hence, the LCC-series compensation topology is chosen in this article. Simple series compensation is used to reduce the complexity and weight of the receiver on the drone side. The combination of multiple proposed transmitters can accommodate the needs of multiple load access scenarios.
2.2. System Circuit Model Considering Multiple Switch States
A unified system circuit model considering multiple reconfiguration switch states is developed, as shown in Figure 2. UDC is the input voltage of the high-frequency inverter. Uin is the fundamental component of the output voltage of the high-frequency inverter. corresponds to the duty cycle of the full-bridge inverter. f is the operating frequency. The corresponding angular frequency is denoted as . The reconfigurable D3-type transmitter is proposed. Rpi (i = 1, 2, 3) and Lpi are the resistance and inductance of the ith transmitting coil, respectively. Si is the corresponding control switch of the ith transmitting coil. Lf and Cf are the fixed parts of the compensation circuit at the transmitting side. Cpi is determined by the excitation states of transmitting coils. Rs and Ls are the resistance and inductance of the receiver on the drone side. Cs is the series compensation capacitance on the drone side. RL is the equivalent load. Mp1p2, Mp1p3 and Mp2p3 are the mutual inductances between the transmitting coils. Mpis are the mutual inductances between the ith transmitting coil and the receiving coil.
Figure 2.
Circuit model of wireless charging system for drones with reconfigurable D3-type transmitter considering switch states.
A transmitter using reconfigurable switches can flexibly select the coils connected in series to the circuit. There are six combinations, as shown in Table 1.
Table 1.
Combinations and switch states.
The total transmitting inductance is Lpsum. The total transmitting resistance is Rpsum. The total mutual inductance is Mps. The output current of the inverter is If. The current of the transmitter coil is Ip. The current of load on the drone side is Is. Based on the circuit theory of mutual inductance, the following circuit equations are established as
where , , , ,
According to the number of excited coils, the excited modes can be categorized into single-coil (1 × Tx), dual-coil (2 × Tx), and triple-coil (3 × Tx) modes. While the transmitting coils are designed the same, .
In the LCC compensation circuit of the transmitting side, the parameters at the resonant state satisfy
In the series resonant compensation circuit of the drone side, the parameters satisfy
Based on the fundamental approximation method, the output voltage of the inverter can be expressed as
The system circuit equations can be simplified as
The output current of the inverter If can be deduced
The current of the transmitter is
The output voltage gain is expressed as
The load current of the drone side is
The receiving power is
The system efficiency is
The relationships of the compensation circuit parameters, circuit currents, output voltage, receiving power and system efficiency with the transmitter switch states and the mutual inductance between the transceivers are obtained from the above circuit modeling and derivation. In order to balance the hardware cost, control complexity, adaptability to receiving positions and the receiving-excitation area ratio, the system characteristics under different excitation modes will be investigated in the subsequent section.
3. Excitation Mode Comparison and Control Method
3.1. Characteristics Analysis of Mutual Inductance Between Reconfigurable Transmitter and Receiver
The schematic diagram of the proposed transmitter and receiver is shown in Figure 3. The parameters for the transmitter units (TA, TB, TC) and the receiver are shown in Table 2. The wire diameter is 2 mm. The center coordinates of the transmitter unit TB are the origin O (0, 0, 0) of the spatial coordinate system. The center coordinates of the receiving coil O’ (Ox, Oy, Oz), where Ox, Oy, and Oz correspond to the misalignment of the receiver in three directions relative to the center of the transmitter.
Figure 3.
The schematic diagram of the proposed transmitter and receiver.
Table 2.
Parameters of coils.
The mutual inductance between the ith turn loop lti of the transmitter and the jth turn loop lrj of the receiver is
where is the vacuum magnetic permeability. is the spatial vector distance between the transmitting circuit element and the receiving circuit element
The mutual inductance between the transmitter unit Tx (TA, TB, TC) with turns NT and the receiver with turns NR is expressed as
Based on the mutual inductance calculation method, by changing the center position of the receiver in the xy plane (Ox varies within [−2lt0, 2lt0], Oy varies within [−2lt0, 2lt0]), the mutual inductance characteristics between the multiple transmitter units and the receiver are shown in Figure 4. Due to the arrangement of the three transmitter units along the x-axis direction, there is a certain degree of fluctuation in the mutual inductance between each transmitter unit and the receiver when Ox changes. The maximum mutual inductance occurs when the receiver is facing the transmitter unit. Therefore, if only one transmitting coil is excited, even if the corresponding single transmitting coil can be adjusted according to load position, there will still be significant fluctuations in the overall mutual inductance between the receiver and transmitter. This lays the foundation for comparative analysis of different excitation modes, position zoning detection, and the transmitter reconfiguration method in the following part.
Figure 4.
The mutual inductance characteristics between the multiple transmitter units and the receiver on the drone side.
3.2. Characteristics Comparison of Multiple Excitation Modes
For the three modes listed in Table 2, according to the mutual inductance calculation method above, by changing the position of the receiver in the x direction at different heights, the characteristics of the total mutual inductance of the receiver and transmitter corresponding to different modes varying with the receiver position are shown in Figure 5a. Similarly, by changing the receiver position in the x direction at different y-axis coordinates Oy, the characteristics of the total mutual inductance corresponding to different modes changing with the receiver position are shown in Figure 5b. In Figure 5a,b, there are significant fluctuations in the mutual inductance characteristics of the single-coil mode and the triple-coil mode with respect to Ox in the middle region.
Figure 5.
Characteristics of the total mutual inductance corresponding to different modes. (a) Different Oz. (b) Different Oy.
As shown in Figure 6a, the characteristics of mutual inductance with Ox under three modes corresponding to Oy = 0 and Oz = 0.03 m are presented. The mutual inductance changes of the three transmitter units TA, TB, and TC under independent excitation in the single-coil mode are shown in Figure 6b. The variations in mutual inductance in the dual-coil mode under the combined excitation of TA + TB and TB + TC are shown in Figure 6d. The mutual inductance changes of TA, TB, and TC excited simultaneously in the triple-coil mode are shown in Figure 6f. In order to ensure the most stable mutual inductance between the transmitter and receiver for the single-coil mode and the dual-coil mode, the intersection points of different characteristic curves are selected as the reconfiguration points of the coil array, as shown in Figure 6c,e.
Figure 6.
Characteristics of the total mutual inductance varying with Ox. (a) Three coil modes. (b) TA, TB, and TC under independent excitation in single-coil mode. (c) reconfiguration in single-coil mode. (d) TA + TB and TB + TC in dual-coil mode. (e) reconfiguration in dual-coil mode. (f) TA, TB, and TC excited simultaneously in triple-coil mode.
Figure 6c,e show the upper envelope curves of the mutual inductance characteristic clusters corresponding to the single-coil mode and the dual-coil mode. As shown in Figure 6c,e,f, select the upper line (upper limit) and lower line (lower limit) of the rectangular window of the effective working area with the maximum value Mmax and minimum value Mmin in the middle region, and the medium range value Mmid-range. The fluctuation value is represented by . The mutual inductance fluctuation rate is represented by .
As mentioned before, in wireless charging systems for drones, the use of large-area independent coils or coil arrays for simultaneous excitation at the transmitting side can construct a stable magnetic field over a large range, achieving greater position freedom of the receiver. However, at the same time, there is a large area of the transmitter not covered by the receiver of the drone, resulting in additional coil losses, electromagnetic field, and heating risk when excited. In this article, the ratio of the receiver area Sr to the actual energized area of the transmitter is defined as the receiving-excitation area ratio ARre.
The comparison of characteristics under various excitation modes of the reconfigurable D3-type transmitter is shown in Table 3. Although the single-coil mode has the highest ARre, the mutual inductance fluctuation rate is large, and the minimum mutual inductance value is low. Furthermore, compared with the triple-coil mode, the dual-coil mode has a higher minimum mutual inductance value, lower mutual inductance fluctuation, and a higher ARre. Therefore, the dual-coil mode is selected as the system reconfiguration mode.
Table 3.
Comparison of characteristics under various excitation modes.
3.3. Transmitter Reconfiguration Method
For the dual-coil mode , the mutual inductance between the transceivers is expressed as
The relationship between the active power output of the inverter and the DC input power of the inverter in Figure 1c is approximately equal [28]. Combining the proportional relationship between the input voltage and the fundamental component of the output voltage using Equation (4), the input current of the inverter can be derived by
The relationship between the inverter input current and the load output voltage gain can be obtained
The system circuit parameters are listed in Table 4. Oy = 0 (ignoring dead time). RDC = 10 Ω. At different Oz, changing the x-axis coordinate Ox of receiver, the characteristic curves of the inverter output current If, inverter DC input current IDC, output voltage gain Gu, and system efficiency are shown in Figure 7. Then, set Oy = 0, Oz = 0.03 m (ignoring dead time), under different RL, the characteristic curves of the inverter DC input current IDC and system efficiency are shown in Figure 8.
Table 4.
System circuit parameters.
Figure 7.
System characteristics varying with Ox (different Oz). (a) If. (b) IDC. (c) Gu. (d) Efficiency.
Figure 8.
System characteristics varying with Ox (different RL). (a) IDC. (b) Efficiency.
By comparing the output voltage gain and system efficiency characteristics of two dual-coil excitation modes under different operating conditions, it can be found that as the receiver position changes, both TA + TB and TB + TC excitation modes have a relatively stable range. The variation pattern of the output voltage corresponds to the variation patterns of the inverter output current ILf and input DC current IDC. The input and output currents of the inverter in the above characteristics can reflect the receiver position. By comparing the current magnitude under different excitation modes, the optimal excitation mode at the current receiving position can be selected. In addition, considering that the output current of the inverter is high-frequency AC, compared with the input DC current of the inverter, the hardware and filtering algorithm of the detection circuit is relatively complex. Therefore, the position zoning detection method based on input DC current detection of the inverter is proposed in this article.
The common reconfiguration of multiple transmitting coil arrays often adopts the one-to-one mode using a single relay switch with dual contact to achieve independent control of each coil. As shown in Figure 2, three transmitting coils commonly use three relay switches. According to the proposed dual-coil mode, the topology is optimized to reduce the number of reconfiguration relay switches. The system topology with a reconfigurable D3-type transmitter based on one relay is proposed in Figure 9, where S is the only switch. The relay control circuit consists of a photocoupler, a transistor, an electromagnetic coil and an armature. The control pin of the relay module is connected to the controller DSP (TMS320F28335, Texas Instruments, Dallas, TX, USA). When the controller outputs a high voltage level, the optocoupler of the relay module is not powered. Consequently, the subsequent transistor circuit is also not powered. The unpowered coil prevents the armature from being attracted. At this time, the relay switch is in the state of S = 0. When the controller outputs a low voltage level, the optocoupler of the relay module is powered. The subsequent transistor circuit is also powered. The powered coil causes the armature to be attracted. At this time, the relay switch is in the state of S = 1. We have added a brief description of the operation of this circuit in the revised manuscript. When S = 0, enter TA + TB excitation mode. When S = 1, reconstruct the transmitter and enter TB + TC excitation mode. It is worth noting that due to the use of LCC compensation at the transmitting side, in order to avoid overcurrent caused by series resonance compensation at the transmitting side, the inverter output needs to be turned off before topology reconfiguration.
Figure 9.
The system topology with reconfigurable D3-type transmitter based on one relay.
As shown in Figure 10, by comparing the characteristic curves of the inverter input DC current and output voltage gain with the position of the receiving coil, in order to ensure that the receiving end can obtain a large output voltage gain at different positions, it is necessary to achieve position zoning detection. Based on the relationship of Equation (18), the magnitude of the inverter input DC current reflects the system output voltage gain characteristics, which can then be used to achieve position zoning detection based on the inverter output DC current. The transmitter can be reconfigured to ensure a stable coupling between the receiver and the transmitter, achieving a stable output voltage. When the misalignment is too large, there will be a significant drop in the output voltage and system efficiency. Therefore, it is necessary to set the system operation boundary. When IDC is less than the threshold IDC0, the system will enter the scheduled restart state.
Figure 10.
Comparison of characteristic curves of inverter input DC current and system output voltage gain.
Based on the above analysis, the transmitter reconfiguration method for the wireless charging system of drones is proposed as shown in Figure 11, with the following specific steps. In order to avoid the overcurrent issue caused by series resonance during primary topology adjustment, the inverter needs to be turned off before the transmitter reconfiguration.
Figure 11.
Flow chart of the transmitter reconfiguration method for wireless charging system of drones.
Step 1: Set and store the DC input current threshold IDC0 of the inverter.
Step 2: Set the switch S to 0, corresponding to TA + TB excitation mode. Set and activate the inverter.
Step 3: Measure and record the DC input current IDC1 of the inverter in TA + TB mode.
Step 4: Set and turn off the inverter. Adjust the switch S to 1 corresponding to TB + TC mode. Set and activate the inverter.
Step 5: Measure and record the DC input current IDC2 of the inverter in TB + TC mode.
Step 6: Compare IDC0, IDC1, and IDC2. If both IDC1 and IDC2 are greater than IDC0, it indicates that the receiver is located within the effective area of the transmitter. Jump to Step 7. Otherwise, it indicates that the receiver is not within the effective area and enters the scheduled restart state. After the scheduled timing ends, it will jump back to Step 2.
Step 7: Compare IDC1, and IDC2. If IDC1 is greater than IDC2, jump to Step 8. Otherwise, jump to Step 11.
Step 8: Set and turn off the inverter. Adjust the switch S to 0, corresponding to TA + TB mode. Set and activate the inverter.
Step 9: Maintain TA + TB mode. Measure and update IDC1.
Step 10: Compare IDC0 and IDC1. If IDC1 is less than IDC0, it indicates that the receiver position has changed. Then jump to Step 4. Otherwise, jump to Step 9 and monitor IDC1.
Step 11: Maintain TB + TC mode. Measure and update IDC2.
Step 12: Compare IDC0 and IDC2. If IDC2 is less than IDC0, it indicates that the receiver position has changed. Then jump to Step 2. Otherwise, jump to Step 11 and monitor IDC2.
4. Experimental Verification
In order to verify the aforementioned theoretical research, the experimental prototype of the wireless charging system for drones based on the reconfigurable D3-type transmitter is built in Figure 12. The transmitting side includes a DC power supply, a high-frequency inverter, the LCC compensation circuit, and the reconfigurable D3-type transmitter. The drone side includes the receiving coil, the series compensation circuit, the rectifier, and the load. The high-frequency inverter adopts DSP (TMS320F28335) as the controller and a full bridge inverter circuit composed of four MOSFETs (IRFP4227PBF, Infineon Technologies AG, Munich, Germany). The system operates at a frequency of 100 kHz. The value of the inverter input voltage is 70 V. The DC load resistance is 10 ohms. A DC current detection module is used to monitor the input DC current of the inverter on the transmitting side. A relay is applied to achieve topology reconfiguration of the proposed transmitter. Four diodes (DSEP15-06A, IXYS, Lampoldshausen, Germany) are used to form a rectifier circuit on the receiving side.
Figure 12.
Experimental prototype of the wireless charging system for drones based on the reconfigurable D3-type transmitter.
The coil parameters are shown in Table 2. Considering the dual-coil excitation mode, the transmitter inductance of series connection coils is 143.10 μH. On the receiving side, the coil inductance is 58.67 μH. The experimental compensation circuit parameters are listed in Table 5. The voltages and currents are measured by using the oscilloscope (TDS2014C, Tektronix, Beaverton, OR, USA), the current probe (SRS6025, Sunraise, Nanjing, China), and the voltage probes (P1300, Cybertek, Shenzhen, China).
Table 5.
Compensation circuit parameters.
Firstly, experimental verification will be conducted on the offset characteristics in the x-axis direction. Under the condition of TA + TB connected to the transmitting side, select a y-axis offset of 0 and 5 cm, respectively, and change the position of the receiving coil within the range of −15 cm to 15 cm along the x-axis direction. Measure the DC input current IDC of the inverter and the DC output voltage of the load. Change the coil combination at the transmitting side to TB + TC, repeat the above steps, and measure the DC input current IDC of the inverter and the DC output voltage of the load. The experimental characteristic curves of the DC input current IDC of the inverter and the DC output voltage are shown in Figure 13a,b.
Figure 13.
The experimental characteristic curves with Ox. (a) DC input current IDC of the inverter. (b) DC output voltage.
Secondly, experimental verification will be conducted on the y-axis offset characteristics. Connect the TB + TC coil to the transmitting side. Select a 5 cm offset in the x-axis direction. Change the receiver position within the range of −15 cm to 15 cm along the y-axis direction. Measure the DC input current IDC of the inverter and the DC output voltage of the load. Connect the TA + TB coil to the transmitting side. Select a −10 cm offset in the x-axis direction. Repeat the above steps. The experimental characteristic curves of the DC input current IDC of the inverter and the DC output voltage are shown in Figure 14.
Figure 14.
The experimental characteristic curves of DC input current IDC of the inverter and DC output voltage.
As shown in Figure 13 and Figure 14, during the process of changing the receiver position, the maximum receiving voltage is 53.8 V. When the fluctuation of the receiving voltage is limited to less than ±10%, the allowable position range along the x-axis direction is −10 cm to 0 cm (corresponding to TA + TB) and 0 cm to 10 cm (corresponding to TB + TC). The allowable position range along the y-axis direction is −7 cm to 7 cm. According to the position zoning detection and transmitter reconfiguration method in Figure 11, the DC input current detection threshold IDC0 of the inverter is set to 3.3 A for the aforementioned output voltage fluctuation range. When the operating condition changes, for example, in order to obtain a wider wireless charging area and higher misalignment tolerance, the DC current threshold can be set as a lower value. A lower DC current threshold value means an allowable lower mutual inductance. Hence, it will also cause a relevant lower efficiency. By detecting and comparing the input current of the inverter under TA + TB and TB + TC excitation modes, the position zoning detection of the receiver is achieved. The corresponding transmitter coils are adjusted to reconfigure the transmitter circuit. As shown in Table 6, the feature table for the inverter input DC current in different charging regions, which includes the corresponding excitation modes, is presented.
Table 6.
The feature table for the inverter input DC current in different charging regions.
For Oy = 0 and 5 cm, the characteristic curve of the output voltage and system efficiency with the receiver position on the drone side is obtained as shown in Figure 15. The receiving power of the system is obtained by multiplying the rectified DC voltage output by the DC current at the receiving side. The power of the transmitting side of the system is obtained by multiplying the DC output voltage of the transmitting side by the DC current. The efficiency of the system is obtained by dividing the receiving power by the transmitting power of the system. The experimental waveforms at several positions during the movement of the receiver on the drone side are shown in Figure 16.
Figure 15.
The characteristic curve of the output voltage and system efficiency. (a) Oy = 0. (b) Oy = 5 cm.
Figure 16.
The experimental waveforms. (a) Output voltage of inverter Uin. Input DC current of inverter IDC. Output voltage of load Uout. Output current of load Iout. (Oy = 0, Ox = 5 cm). (b) Output voltage of inverter Uin. Input DC current of inverter IDC. Output voltage of load Uout. Output current of load Iout. (Oy = 0, Ox = 10 cm). (c) Output voltage of inverter Uin. Input DC current of inverter IDC. Output voltage of load Uout. Output current of load Iout. (Oy = 5 cm, Ox = 10 cm). (d) Output voltage of inverter Uin. Input DC current of inverter IDC. Output voltage of load Uout. Output current of load Iout. (Oy = 5 cm, Ox = 5 cm). (e) Output voltage of inverter Uin. Output current of inverter If. Output voltage of load Uout. Output current of load Iout. (Oy = 5 cm, Ox = 5 cm). (f) Output voltage of inverter Uin. Output current of inverter If. Input voltage of rectifier Urec-in. Input current of rectifier Irec-in. (Oy = 5 cm, Ox = 5 cm).
As shown in Figure 17, the magnetic field distribution of the proposed reconfigurable D3-type transmitter under different combinations of coil unit excitation modes (TA + TB and TB + TC) is presented.
Figure 17.
The magnetic field distribution of the proposed reconfigurable D3-type transmitter. (a) TA + TB excitation mode. (b) TB + TC excitation mode.
In addition, experimental research on the rotation of the receiver is also conducted. As shown in Figure 18, the characteristic curves of the output DC voltage and system efficiency are obtained by changing the rotation angle of the receiver. Considering the symmetry of the couplers, 0 to 90 degrees is selected as the range of angle variation in the rotation characteristic curve. The fluctuation of load output voltage is ±7%.
Figure 18.
The characteristic curves of the output DC voltage and system efficiency vary with rotation angle.
As shown in Table 7, the comparison with relevant literature on system structure, hardware composition, and system characteristics is presented. The existing works have practical limitations in terms of hardware usage, such as sensors or switches. In addition, misalignment tolerance, receiver excitation ratio, and hardware cost need to be considered comprehensively. Compared with existing literature, it takes into account the hardware cost, control complexity, adaptability to receiving positions and the receiving-excitation area ratio comprehensively in this article. The reconfigurable D3-type transmitter, one DC current sensor and one relay switch are utilized. Based on the position zoning detection and transmitter reconfiguration method proposed in this article, the maximum receiving power is 289.44 W. The maximum system DC-DC efficiency exceeds 87.05%. When the received voltage fluctuation does not exceed ±10%, the ratio of the maximum offset in the x-axis and y-axis directions to the side length of the receiving coil reaches 66.7% and 46.7%, respectively. The position zoning detection and transmitter reconfiguration method also achieves the ARre of 37.5%, significantly reducing the excitation area of the transmitter not covered by the receiver.
Table 7.
Comparison of system structure, hardware composition and system characteristics.
5. Conclusions
In order to balance the load location range, the excitation area of the transmitter, additional hardware costs, receiving-excitation area ratio, receiving voltage fluctuations, and positioning switching complexity, a WPT system based on a reconfigurable D3-type transmitter is proposed in this article. The unified system circuit model considering the reconfiguration switch states is developed. The dual-coil excitation mode is selected after comparative analysis, taking into account factors such as the number of excitation coils, the minimum mutual inductance, the mutual inductance fluctuation, and the receiving-excitation area ratio. The relationship between the inverter input current and load output voltage gain has been established. The position zoning detection based on one DC input current detection is proposed. The topology of the reconfigurable D3-type transmitter is simplified based on one switch. The position zoning detection and transmitter reconfiguration method based on one detection sensor of DC current and one relay is proposed. The receiving-excitation area ratio is 37.5%, significantly reducing the excitation area of the transmitter not covered by the receiver. The maximum receiving power is 289.44 W. The maximum system DC-DC efficiency exceeds 87.05%.
Author Contributions
Conceptualization, H.L. and R.W.; methodology, H.L.; software, H.L. and L.W.; validation, H.L. and L.W.; formal analysis, H.L. and R.W.; investigation, H.L. and D.H.; resources, H.L.; data curation, H.L. and L.W.; writing—original draft preparation, H.L.; writing—review and editing, L.W. and J.W.; visualization, J.W.; supervision, H.L.; project administration, H.L.; funding acquisition, H.L. All authors have read and agreed to the published version of the manuscript.
Funding
This work was supported in part by the National Natural Science Foundation of China (52107003), in part by the Chinese Postdoctoral Science Foundation (2021M690867), and in part by the Postdoctoral Fund of Jiangsu Province (2021K030A).
Data Availability Statement
The data in this study are available upon request to the corresponding author.
Conflicts of Interest
Author Rong Wang was employed by the company State Grid Jiangsu Electric Power Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
- Choi, H.-W.; Kim, H.-J.; Kim, S.-K.; Na, W.S. An Overview of Drone Applications in the Construction Industry. Drones 2023, 7, 515. [Google Scholar] [CrossRef] [Scilit]
- Su, W.; Wang, W.; Lyu, X.; Dou, Z.; Wang, J. Field Equivalent Modeling Analysis of Wireless Charging System with Metal Foreign Objects. Electr. Power Eng. Technol. 2023, 42, 226–232. [Google Scholar]
- Liu, H.; Huang, D.; Wang, L.; Wang, R. Misalignment Tolerance Improvement of a Wireless Power Supply System for Drones Based on Transmitter Design with Multiple Annular-Sector-Shaped Coils. Drones 2024, 8, 773. [Google Scholar] [CrossRef] [Scilit]
- Liu, H.; Huang, X.; Tan, L.; Guo, J.; Wang, W.; Yan, C.; Xu, C. Dynamic Wireless Charging for Inspection Robots Based on Decentralized Energy Pickup Structure. IEEE Trans. Ind. Inform. 2018, 14, 1786–1797. [Google Scholar] [CrossRef] [Scilit]
- Wang, H.; Xiao, C.; Liang, Z.; Shen, W. Intermittent Charging Method Making the Receiving Coil of Wireless Charging System Inside Cardiac Pacemaker. IEEE Trans. Instrum. Meas. 2025, 74, 4009412. [Google Scholar] [CrossRef] [Scilit]
- Huang, T.; Bian, Z.; Xu, C.; Wang, R.; Zhang, M.; Tan, L. Design of transmitter power supply for wireless charging system based on SiC device. Electr. Power Eng. Technol. 2021, 40, 87–93. [Google Scholar]
- Hu, H.; Hu, H.; Chen, F.; Dai, X.; Sun, Y. Efficiency Improvement Strategy Based on Frequency Reduction with Constant Current Characteristic for Underwater Wireless Power Transfer Systems. IEEE Trans. Power Electron. 2025, 40, 14038–14049. [Google Scholar] [CrossRef] [Scilit]
- Wang, N.; Zhao, Y.; Li, C.; Wang, P.; Zhang, C. Design, Manufacture, and Experimental Verification of Contactless Power Supply Coupler for Rotary Wireless Sensor Node of Water-Lubricated Bearing. IEEE Trans. Instrum. Meas. 2023, 72, 7507011. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Z.; Zhang, B. Development and key technologies of dynamic wireless power transfer system for mobile load. Electr. Power Eng. Technol. 2020, 39, 21–30. [Google Scholar]
- Cai, C.; Du, Y.; Wang, J.; Jiang, Y.; Yuan, Z.; Zhang, X.; Wan, L.; Wu, X. A Dual-Objective Magnetic Integration Based WPT Link for UAV Hover Charging with High-Resolution Dynamic Position Detection. IEEE Trans. Power Electron. 2025, 40, 14363–14367. [Google Scholar] [CrossRef] [Scilit]
- Li, T.; Tian, E. Robust H∞ Control for ICPT Process with Coil Misalignment and Time Delay: A Sojourn-Probability-Based Switching Case. IEEE Trans. Circuits Syst. I Regul. Pap. 2021, 68, 5156–5167. [Google Scholar] [CrossRef] [Scilit]
- Xia, C.; Wang, W.; Ren, S.; Wu, X.; Sun, Y. Robust Control for Inductively Coupled Power Transfer Systems with Coil Misalignment. IEEE Trans. Power Electron. 2018, 33, 8110–8122. [Google Scholar] [CrossRef] [Scilit]
- Li, Z.; Zhu, C.; Jiang, J.; Song, K.; Wei, G. A 3-kW Wireless Power Transfer System for Sightseeing Car Supercapacitor Charge. IEEE Trans. Power Electron. 2017, 32, 3301–3316. [Google Scholar] [CrossRef] [Scilit]
- Zhang, X.; Xue, R.; Wang, F.; Xu, F.; Chen, T.; Chen, Z. Capacitor Tuning of LCC-LCC Compensated IPT System with Constant-Power Output and Large Misalignments Tolerance for Electric Vehicles. IEEE Trans. Power Electron. 2023, 38, 11928–11939. [Google Scholar] [CrossRef] [Scilit]
- Sun, Z.; Hu, G.; Li, G.; Wang, Y.; Guan, Y.; Xu, D. Analysis and Design of a 6.78 M Wireless Power Transfer System with Strong Misalignment Tolerance Based on Simplified Impedance Trajectory Tracing. IEEE Trans. Ind. Electron. 2024, 71, 13470–13475. [Google Scholar] [CrossRef] [Scilit]
- Li, Z.; Liu, H.; Huo, Y.; He, J.; Tian, Y.; Liu, J. High-Misalignment Tolerance Wireless Charging System for Constant Power Output Using Dual Transmission Channels with Magnetic Flux Controlled Inductors. IEEE Trans. Power Electron. 2022, 37, 13930–13945. [Google Scholar] [CrossRef] [Scilit]
- Cota, K.A.; Gray, P.A.; Pathmanathan, M.; Lehn, P.W. An Approach for Selecting Compensation Capacitances in Resonance-Based EV Wireless Power Transfer Systems with Switched Capacitors. IEEE Trans. Transp. Electrif. 2019, 5, 1004–1014. [Google Scholar] [CrossRef] [Scilit]
- Wen, F.; Cheng, X.; Li, Q.; Zhao, W.; Zhu, X.; Wu, Y. A Strong Misalignment Tolerance Dual-Channel Coupler for Wireless Power Transfer System. IEEE Trans. Appl. Supercond. 2021, 31, 0601005. [Google Scholar] [CrossRef] [Scilit]
- Zhai, Y.; Li, Y.; Yang, Q.; Zhu, L.; Gao, R. A Novel Type of Transmitter with A-R Coil for Large-Scale Spatial Wireless Power Transfer. IEEE J. Emerg. Sel. Top. Power Electron. 2024, 13, 4074–4085. [Google Scholar] [CrossRef] [Scilit]
- Zhao, Y.; Shen, S.; Yin, F.; Wang, L. A High Misalignment-Tolerant Hybrid Coupler for Unmanned Aerial Vehicle WPT Charging Systems. IEEE Trans. Transp. Electrif. 2025, 11, 1570–1581. [Google Scholar] [CrossRef] [Scilit]
- Li, Z.; Li, X.; Zhou, Y.; Liu, Y.; Ban, M. Improving Misalignment Tolerance for the Wireless Charging System Using Multiple Coils Coupler. IEEE Trans. Power Electron. 2024, 39, 7721–7735. [Google Scholar] [CrossRef] [Scilit]
- Rong, C.; He, X.; Wu, Y.; Qi, Y.; Wang, R.; Sun, Y.; Liu, M. Optimization Design of Resonance Coils with High Misalignment Tolerance for Drone Wireless Charging Based on Genetic Algorithm. IEEE Trans. Ind. Appl. 2022, 58, 1242–1253. [Google Scholar] [CrossRef] [Scilit]
- Ieong, C.-F.; Chan, P.-I.; Iam, I.-W.; Lam, C.-S. An LCC-S-S Compensated Three-coil Wireless Charging System for Offshore USV Charging. IEEE J. Emerg. Sel. Top. Power Electron. 2025, 13, 6768–6779. [Google Scholar] [CrossRef] [Scilit]
- Xu, H.; Tan, L.; Gui, L.; Wu, Z.; Li, H.; Huang, X. Design of Magnetic Coupler for Wireless Power Transmission System Based on Magnetic Field Reconstruction. IEEE Trans. Power Electron. 2024, 39, 2855–2866. [Google Scholar] [CrossRef] [Scilit]
- Al Mahmud, S.A.; Panhwar, I.; Jayathurathnage, P. Large-Area Free-Positioning Wireless Power Transfer to Movable Receivers. IEEE Trans. Ind. Electron. 2022, 69, 12807–12816. [Google Scholar] [CrossRef] [Scilit]
- Huh, S.; Park, B.; Choi, S.; Shin, Y.; Kim, H.; Kim, J.; Park, J.; Park, D.; Ahn, S. Transmitter Coils Selection Method for Wireless Power Transfer System with Multiple Transmitter Coils and Single Receiver Coil. IEEE Trans. Power Electron. 2023, 38, 4092–4109. [Google Scholar] [CrossRef] [Scilit]
- Cai, C.; Yang, J.; Wu, S.; Zhang, H.; Chai, W. Landing Position Detection and Array Coil Matching of Multi-UAVs Wireless Power Transfer System. IEEE Trans. Transp. Electrif. 2025, 11, 11054–11064. [Google Scholar] [CrossRef] [Scilit]
- Guo, Y.; Zhang, Y.; Li, S.; Tao, C.; Wang, L. Load Parameter Joint Identification of Wireless Power Transfer System Based on the DC Input Current and Phase-Shift Angle. IEEE Trans. Power Electron. 2020, 35, 10542–10553. [Google Scholar] [CrossRef]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.