1. Introduction
Biomedical engineering continues to benefit from advances in fluid mechanics, biomechanics, acoustics, and computational science. Improved imaging techniques, experimental diagnostics, and numerical methods have made it possible to investigate physiological processes with increasing spatial and temporal resolution. These developments are contributing to a better understanding of the interactions between fluid flow, tissue deformation, and mechanical forces in the human body, and are providing new opportunities for disease diagnosis, surgical planning, medical device development, and patient-specific treatment.
An important feature of recent progress is the growing integration of experimental measurements with computational modeling. While experiments and clinical imaging provide essential information about physiological behavior, numerical simulations can reveal details of flow fields, stresses, and tissue responses that are difficult to measure directly. Machine learning and reduced-order modeling have also provided opportunities to extend these investigations to more complex systems while substantially reducing computational costs. However, translating these advances into reliable clinical applications remains a significant challenge, requiring close collaboration between engineers, clinicians, and imaging specialists.
The first Special Issue, Fundamentals and Applications of Fluid Mechanics and Acoustics in Biomedical Engineering [1], which brought together fourteen papers spanning airway aerodynamics, phonation, obstructive sleep apnea, cardiovascular flows, and blood rheology, and has since accumulated over 22,000 views, approximately 6,500 downloads, and 39 citations as of the time of writing. Building on that foundation, this second Special Issue expands the scope to include additional aspects of biomechanics and biomedical device development. The seven papers published in this collection address cardiovascular flow and valve dynamics, platelet deformation, vocal fold biomechanics, focused ultrasound diagnostics, cranial mechanics, and prosthetic design. Although these investigations concern different physiological systems, they share an emphasis on understanding the underlying physical mechanisms and developing engineering approaches that can contribute to improved healthcare.
2. Recent Advances Highlighted in This Special Issue
2.1. Cardiovascular Hemodynamics and Multiscale Modeling
Cardiovascular flow remains a central area of biomedical fluid mechanics because of the strong coupling between blood motion, vascular geometry, tissue deformation, and disease progression.
Fan and Sundström [2] investigated vortex dynamics in the sinus of Valsalva, the three pockets behind the aortic valve leaflets that regulate valve mechanics and coronary perfusion, using fluid–structure interaction (FSI) simulations of an idealized aortic valve with neo-Hookean leaflet material representation. Their study showed that increasing leaflet stiffness amplifies the peak vorticity of the sinus vortex and extends its residence time; the phase-space trajectory of the vortex evolves from a simple loop to a pronounced spiral as stiffness increases, reflecting longer diffusion times and a reduced pressure differential during leaflet closure. These findings establish a hemodynamic mechanism linking early-stage changes in leaflet compliance to the flow environment that drives endothelial mechanobiological signaling, with potential to provide a physical basis for the clinical observation that hemodynamic disturbance precedes overt calcification.
A complementary investigation by Liu et al. [3] applied blood speckle imaging (BSI), a technique that derives velocity fields from the speckle pattern of transesophageal echocardiography (TEE) signals, to assess hemodynamic changes in ten patients with non-stenotic congenital aortic root disease undergoing valve-sparing root replacement (VSRR). Preoperative and postoperative comparisons revealed statistically significant changes toward a more favorable hemodynamic profile: the oscillatory shear index (OSI) was reduced from 0.054 ± 0.021 to 0.028 ± 0.016 (p = 0.004), while the peak wall shear stress (WSS) increased from 1.94 ± 0.70 Pa to 3.70 ± 1.49 Pa (p = 0.004). Because BSI requires no contrast agent and is fully compatible with the intraoperative setting, it illustrates how detailed flow measurements can provide potentially useful information for intraoperative assessment beyond conventional assessments of valve performance.
Together, these two studies highlight complementary approaches: computational modeling to investigate the physical mechanisms governing cardiovascular flow, and clinical imaging to assess the hemodynamic consequences of surgical intervention. Their integration offers a path toward hemodynamically guided surgical planning.
At a smaller scale, Laudato [4] addressed the computational challenge of coupling the deformation mechanics of individual platelets, governed by molecular-level forces, with the continuum hemodynamics of flowing blood. A deep operator network (DeepONet) was trained on dissipative particle dynamics (DPD) simulations in LAMMPS, representing the platelet as a three-dimensional ellipsoidal shell with approximately 20,000 harmonic spring particles, and spanning ten capillary numbers (Ca* = 0.07–0.77) covering a range of physiologically relevant regimes. The surrogate achieved median prediction errors below 1% and 90th-percentile errors below 3%, with a considerable computational speedup. This is the first demonstration of a particle-based platelet surrogate having the potential of integration into continuum CFD, opening a practical path toward multiscale thrombosis models. Its predictive capabilities beyond the training conditions, particularly in complex patient-specific flows, will need to be established in future work.
2.2. Vocal Fold Biomechanics and Phonation
The interaction between airflow and deformable vocal fold tissues is central to voice production, and understanding this coupling is important for improving surgical interventions intended to restore phonation in patients with vocal fold paralysis.
Farbos de Luzan et al. [5] investigated the influence of medialization implant location on vocal fold geometry and vibration using high-speed three-dimensional digital image correlation (3D-DIC) in an ex vivo canine hemilarynx model. Two implant configurations were compared: infraglottal (IM) placement, with the implant body positioned below the glottal plane, and glottal (GM) placement at the level of the glottis. Measurements across two adduction levels (AL1, AL2) showed that IM placement consistently increased the glottal divergence angle and dynamic vertical thickness, particularly in under-adducted states (AL1), while also producing a statistically significant reduction in mean airflow rate (Q) at AL1, consistent with more efficient glottal closure and improved phonatory aerodynamics. These findings provide the first quantitative biomechanical evidence that infraglottal placement may offer superior functional outcomes in under-adducted vocal folds. An important additional contribution is the validated methodology for dynamic vocal fold thickness quantification, which provides measurements that cannot be obtained from static observations alone and offers a replicable platform for evaluating future phonosurgical implant designs.
2.3. Acoustic Measurements and Biomedical Applications
Accurate characterization of acoustic fields is essential for ensuring both the effectiveness and safety of focused ultrasound (FU) in therapeutic applications, including tumor thermal ablation, the transcranial treatment of neurological disorders, and pain management.
Xu et al. [6] developed a noninvasive technique for measuring FU fields using laser deflection acoustic quantification (LDAQ). The method combines the acousto-optic deflection effect, in which an ultrasound field deflects a laser beam in proportion to the local refractive index gradient, with tomographic Radon-transform inversion to reconstruct the spatial distribution of acoustic pressure. Validation at a 0.84 MHz transducer demonstrated low root-mean-square errors relative to simulation and hydrophone measurements, within the limits acceptable for pre-clinical FU system qualification. Because LDAQ operates without inserting any sensor into the acoustic field, it avoids the physical perturbation and probe-damage concerns that limit conventional hydrophone-based characterization at megapascal pressure amplitudes. Further development could support improved ultrasound device calibration, treatment planning, and safety assessment across a broader range of clinical FU modalities.
2.4. Skeletal Biomechanics and Medical Device Development
This edition extends the collection into skeletal mechanics and prosthetic design, broadening the scope of the Special Issue beyond fluid-related physiological processes.
Yang et al. [7] used finite element analysis (FEA) to investigate how different cranial suture geometries affect mechanical responses under applied loading. Six model variants were compared, progressing from closed sutures to increasingly complex geometries including layered sinusoidal configurations with sutural bone islands, subjected to a 50 kPa impact load and a 98 N bilateral tensile load simulating mastication. Layered sinusoidal suture geometries delayed peak stress propagation by 19–36% relative to closed sutures under impact loading, primarily through geometric interlocking, while staggered suture–bone arrangements enhanced shear resistance. Importantly, all open suture configurations produced sub-micron deformations, far below pathological thresholds under the applied loading conditions, demonstrating that the geometric complexity of adult cranial sutures provides effective mechanical resistance and that suture geometry, rather than the simple presence or absence of fusion, governs the cranium’s mechanical response. As with all idealized FEA studies, further validation with patient-specific geometries and material properties will be necessary.
Abdreshova et al. [8] investigated the development of a modular knee prosthesis through three successive design generations (V1 through V3), evaluated using SolidWorks CAD 2024 modeling and kinematic simulation. Each design cycle addressed limitations of its predecessor: the V3 design achieves an extended range of motion, a reduced mass, a lower center of gravity, a smoother dynamic response, and full modular compatibility with foot and ankle components. The systematic biomechanical evaluation framework, tracking the range of motion, dynamic response, and mass distribution through the design iterations, illustrates how structured engineering analysis can guide prosthetic development toward potential clinical applicability. The modular architecture of the V3 design is particularly noteworthy for its practical potential, though extensive experimental testing and patient-based clinical validation remain necessary before translation to practice.
3. Challenges and Future Research Directions
The contributions to this Special Issue demonstrate the progress achieved through advanced computational methods, imaging techniques, and experimental measurements. They also highlight several challenges that should guide future research.
3.1. Integration of Experimental Measurements and Computational Models
A continuing challenge in biomedical engineering is the reliable validation of numerical simulations. Biological systems involve complex geometries, deformable tissues, unsteady flows, and considerable variability in material properties, making predictions sensitive to modeling assumptions and boundary conditions. Future studies should place greater emphasis on combining time-resolved experimental measurements with computational simulations: in cardiovascular applications, simultaneous measurements of flow, wall motion, and pressure could provide stronger validation of FSI models such as those developed by Fan and Sundström; in phonation research, combining 3D-DIC measurements of the type introduced by Farbos de Luzan et al. with acoustic and aerodynamic outputs could support validated laryngeal models. Validation should extend beyond global quantities to include local flow structures, stress distributions, and transient behavior, and quantifying experimental and computational uncertainties will be essential for establishing confidence in predictions.
3.2. Patient-Specific Modeling and Clinical Translation
Although idealized geometries are useful for identifying fundamental physical mechanisms, their results may not fully represent the complexity of individual patients. Patient-specific models incorporating realistic anatomical geometry, tissue properties, and physiological boundary conditions are therefore an important direction for future research. For cardiovascular applications, the BSI approach demonstrated by Liu et al. could be integrated with pre-operative patient-specific CFD to provide surgeons with predicted post-operative hemodynamics as a decision-support tool, with protocols standardized across valve and vessel pathologies including mitral valve disease, aortic coarctation, and congenital ventricular septal defects. In phonosurgery, patient-specific finite element models of the hemilarynx built from high-resolution CT or MRI data, validated against 3D-DIC measurements, could predict the glottal geometry, aeroacoustic output, fundamental frequency, harmonics-to-noise ratio, and maximum phonation time, as a function of implant type, size, and placement, reducing reliance on intraoperative auditory assessment. For cranial mechanics, extending Yang et al.’s parametric FEA to incorporate heterogeneous cortical and trabecular bone properties from CT-derived microstructural data, and to pediatric cranial sutures relevant to craniosynostosis, would enable individualized surgical outcome prediction. In each domain, determining whether computationally derived quantities can reliably predict clinically meaningful outcomes will require larger patient studies and longitudinal validation.
3.3. Multiscale and Multiphysics Modeling
Many physiological processes involve interactions across widely different spatial and temporal scales. The platelet deformation surrogate developed by Laudato demonstrates one path forward: bridging the scale gap between molecular-level particle dynamics and continuum hemodynamics to enable multiscale thrombosis modeling. Future research could extend this approach to additional blood cell types, red blood cells under shear and confinement, leukocytes undergoing margination and adhesion, and circulating tumor cells, and to incorporate platelet activation chemistry alongside deformation, toward patient-specific thrombosis models that account for individual rheological profiles and antiplatelet drug effects. The mechanobiological link between the hemodynamic disturbances identified by Fan and Sundström and the initiation of CAVD also calls for multiphysics models coupling FSI-derived wall shear stress fields with biological models of endothelial and valve interstitial cell activation, lipid infiltration, and calcium deposition. Similarly, vocal fold vibration involves tightly coupled interactions among airflow, tissue mechanics, and acoustics, and skeletal biomechanics require connecting local material properties to the response of larger anatomical structures. Developing computational frameworks that reliably connect these scales remains a major challenge for the field.
3.4. Artificial Intelligence and Computational Efficiency
Machine learning and artificial intelligence are playing an increasingly important role in biomedical engineering, extending from image processing and data analysis to the development of surrogate models that substantially reduce computational costs. The platelet deformation study illustrates the promise of these methods, achieving a significant speedup with small errors. Nevertheless, computational speed should not come at the expense of physical accuracy or generalizability. Future developments should emphasize physics-informed and physics-constrained learning, uncertainty quantification, and the ability of models to generalize beyond their training conditions to complex physiological flows and patient-specific geometries. Hybrid approaches combining high-fidelity simulations with reduced-order or machine-learning models may be particularly valuable, with the long-term objective of providing sufficiently accurate predictions within the time constraints of clinical decision-making.
3.5. Improved Diagnostics and Non-Invasive Measurements
The development of non-invasive diagnostic techniques is another important research direction. The LDAQ method introduced by Xu et al. offers a notable example: its extension to three-dimensional field reconstruction, using a rotating aperture or multi-view optical configuration, would enable characterization of the asymmetric transducer arrays used in phased-array FU systems, while adaptation to pulsed-wave protocols using time-resolved optical detection would make it applicable to sonoporation-mediated drug delivery and transcranial neuromodulation. More broadly, advances in optical measurements, ultrasound imaging, and high-speed imaging offer opportunities to quantify physiological processes without significantly disturbing the systems under investigation. The integration of advanced diagnostics with computational models may ultimately provide a more comprehensive assessment of physiological function than either approach alone.
3.6. From Engineering Development to Clinical Application
Perhaps the most important challenge is translating engineering advances into practical medical benefits. Many computational and experimental investigations demonstrate promising results under controlled conditions, but relatively few progress to extensive clinical validation. Medical devices and diagnostic techniques must satisfy requirements involving safety, reproducibility, durability, patient comfort, and cost. For prosthetic devices such as the modular knee prosthesis described by Abdreshova et al., future work should evaluate additive manufacturing compatibility, assessing whether fused deposition modeling or selective laser sintering can reproduce the required structural tolerances using biocompatible polymers or titanium alloys, and include prospective clinical trials comparing the V3 design with standard-of-care prostheses across ambulation distance, gait symmetry, and patient-reported outcomes. For computational surgical planning tools, the criterion is not model accuracy alone but a demonstrated improvement in treatment decisions or patient outcomes. Future studies should therefore consider clinical requirements from the early stages of development, supported by multidisciplinary collaboration, standardized validation procedures, and carefully designed clinical investigations.
4. Conclusions
The seven papers published in this second Special Issue illustrate the broad and growing contributions of fluid mechanics, biomechanics, and acoustics to biomedical engineering. They demonstrate how advanced imaging, experimental diagnostics, computational modeling, and machine learning can deepen our understanding of cardiovascular function, phonation, tissue mechanics, and biomedical device performance. Together, they offer new tools for hemodynamic assessment in the operating room, new computational frameworks for multiscale cardiovascular modeling, new non-invasive methods for acoustic field characterization, deeper biomechanical understanding of phonosurgical interventions, and principled approaches to the development and evaluation of skeletal implants.
Despite these advances, important challenges remain. The accuracy of computational predictions, the representation of complex physiological interactions across scales, and the translation of research findings into clinical practice all require further investigation. Future progress will depend increasingly on combining fundamental physical understanding with advanced measurement techniques, validated computational tools, and clinically relevant patient studies. The development of patient-specific and multiscale models, supported by reliable experimental data and efficient computational methods, offers considerable promise for improving healthcare outcomes.
We hope that the contributions to this Special Issue will stimulate further collaboration among researchers in engineering, physics, biology, and medicine, and encourage new investigations that connect fundamental scientific advances with improvements in human health. We thank the authors for their contributions and the reviewers for their efforts in maintaining the scientific quality of this collection. We also appreciate the support of the editorial staff of Bioengineering throughout the preparation of this Special Issue.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Little, I.; Gutmark, E. Fundamentals and Applications of Fluid Mechanics and Acoustics in Biomedical Engineering. Bioengineering 2024, 11, 1125. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Fan, J.; Sundström, E. Vortex Dynamics in the Sinus of Valsalva. Bioengineering 2025, 12, 279. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Liu, S.; Tretter, J.T.; Dakik, L.; Najm, H.K.; Goswami, D.; Ryan, J.K.; Sundström, E. Flow Characteristics by Blood Speckle Imaging in Non-Stenotic Congenital Aortic Root Disease Surrounding Valve-Preserving Operations. Bioengineering 2025, 12, 776. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Laudato, M. A Neural-Operator Surrogate for Platelet Deformation Across Capillary Numbers. Bioengineering 2025, 12, 958. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Farbos de Luzan, C.; Michaud-Dorko, J.; Howell, R.J.; Gutmark, E.; Oren, L. Dynamically Quantifying Vocal Fold Thickness: Effects of Medialization Implant Location on Glottal Shape and Phonation. Bioengineering 2025, 12, 667. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xu, Y.; Liu, H.; Ma, Y.; Bai, X.; Hu, Q.; Cai, Y.; Zhang, H.; Huang, T.; Liu, M.; Li, J.; et al. Laser Deflection Acoustic Field Quantification: A Non-Invasive Measurement Technique for Focused Ultrasound Field Characterization. Bioengineering 2026, 13, 22. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yang, H.; Yuan, S.; Yan, Y.; Zhou, L.; Zheng, C.; Li, Y.; Li, J. Finite Element Analysis of the Effects of Different Shapes of Adult Cranial Sutures on Their Mechanical Behavior. Bioengineering 2025, 12, 318. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Abdreshova, S.; Akhmejanov, S.; Ozhikenov, K.; Zhetenbayev, N.; Nurgizat, Y.; Bizhanov, D.; Sultan, A.; Ayazbay, A.-A.; Zharmagambetova, M.; Sergazin, G. Development and Biomechanical Evaluation of a Modular Knee Prosthesis: From Conceptual V1 Design to an Improved V3 Model. Bioengineering 2026, 13, 201. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.