Skip to Content
PhotonicsPhotonics
  • Article
  • Open Access

27 November 2026

15 Pages

Double-Phase Encoded Asymmetric Differentiator Metasurface for Quantitative Phase Imaging

,
,
,
and
1
School of Science, Harbin Institute of Technology, Weihai 264209, China
2
Department of Physics, Harbin Institute of Technology, Harbin 150001, China
*
Author to whom correspondence should be addressed.
Photonics2026, 13(12), 1122;https://doi.org/10.3390/photonics13121122 
(registering DOI)
This article belongs to the Special Issue Metasurfaces for Next‑Generation Nanophotonic Devices

Abstract

Quantitative phase imaging (QPI) provides label-free visualization of transparent specimens and is widely used in optical metrology and biomedical inspection, yet compact implementations remain difficult. A quantitative phase imaging method using a single dielectric metasurface is proposed, in which the metasurface is placed at the Fourier plane of a 4f system and realizes an asymmetric spatial differentiator with a monotonically varying transfer function based on double-phase encoding and circular-polarization multiplexing. Double-phase encoding achieves amplitude modulation via pure phase modulation, allowing a single-layer all-dielectric metasurface to synthesize a strictly monotonic, non-negative asymmetric complex-amplitude transfer function, so that one layer of silicon nanopillars provides a strictly monotonic, non-negative response and resolves the sign of the gradient, which symmetric differentiators cannot provide. Circular-polarization multiplexing supplies a complementary channel in the same layer; the ratio of the two channel images removes the influence of incident amplitude, and a total-variation-regularized Poisson integration reconstructs the quantitative phase from the phase gradient. Full-wave simulations confirm the monotonicity and linearity of the response and give a relative reconstruction error of 0.3–1.4% with favorable robustness to gradient noise. The scheme provides a compact and scalable route toward quantitative phase imaging.

1. Introduction

Quantitative phase imaging (QPI) has emerged as an indispensable tool for the label-free visualization of transparent specimens, enabling the characterization of cellular morphology, refractive index distribution, and thickness variations with nanoscale precision [1,2,3]. Existing QPI techniques can be broadly categorized into three classes: interferometric methods, computational imaging approaches, and wavefront sensing techniques [4]. Interferometric methods offer high accuracy but impose stringent requirements on mechanical stability and optical alignment. Computational imaging approaches typically require an iterative reconstruction step, which places a substantial computational burden on data processing [5,6]. Wavefront sensing methods, such as the Shack–Hartmann wavefront sensor, are capable of real-time operation but suffer from an inherent trade-off between spatial resolution and numerical aperture [7,8]. These intrinsic contradictions have motivated the pursuit of compact QPI schemes that can be integrated into portable or in-line inspection systems.
In recent years, advances in nanophotonics have stimulated considerable interest in miniaturizing optical imaging systems through diffractive optical elements, particularly metasurfaces [9,10,11,12,13,14]. Metasurfaces, composed of ultrathin planar structures with subwavelength scatterers, offer remarkable capabilities for manipulating optical fields at the subwavelength scale. They have been successfully integrated with standard optical components, such as polarization cameras and CCDs, greatly facilitating the development of compact phase imaging [15,16]. Recent studies have further demonstrated that single-layer metasurfaces can serve as convolution operators for all-optical image processing through phase-only modulation or complex-amplitude modulation achieved via double-phase encoding [17,18,19]. However, most existing metasurface-based image processors rely on symmetric transfer functions, which are limited to qualitative operations like edge enhancement and cannot discriminate between positive and negative phase gradients [20,21,22], thereby hindering their application in quantitative phase reconstruction. Several approaches have realized asymmetric transfer functions for phase imaging, and they are distinguished by what they measure and by how the asymmetry is produced. Detector-integrated plasmonic metasurfaces convert the local direction of propagation into a photocurrent and perform quantitative phase imaging on a customized pixel array [23]. Inverse-designed nonlocal plasmonic filters provide an asymmetric linear transfer function over a large numerical aperture for phase-contrast imaging [24]. A guided-mode-resonance dielectric angular filter emulates the Zernike phase plate and yields a phase-contrast image whose quantitative readout is calibrated in the weak-phase regime [25]. In the context of QPI, multilayer cascaded metasurfaces [26] face the challenge of interlayer alignment, while spatially multiplexed Pancharatnam–Berry (PB) metasurfaces [27,28] recover the phase from a unidirectional gradient through differential bias but introduce additional errors from image registration. These schemes motivate a single-layer, all-dielectric, common-path implementation in which the asymmetric transfer function is written analytically into the layer.
In this paper, we propose and numerically validate a quantitative phase imaging method in which a single-layer all-dielectric PB metasurface is deployed at the Fourier plane of a 4f optical system. What fundamentally distinguishes this approach is the synthesis of a strictly monotonic asymmetric transfer function, which intrinsically eliminates the sign ambiguity of conventional symmetric differentiators. To reconcile the phase-only constraint of dielectric metasurfaces with the amplitude-modulation requirement of asymmetric transfer functions, we adopt a double-phase encoding strategy, whose independent control of amplitude and phase allows an asymmetric transfer function to be realized within a single metasurface layer. We further exploit circular-polarization multiplexing to generate the target asymmetric response and a complementary reference channel, yielding a self-referenced phase gradient measurement that suppresses incident-amplitude fluctuations and enables high-fidelity quantitative phase reconstruction. Full-wave electromagnetic simulations verify the effectiveness of the proposed scheme and demonstrate its high-fidelity phase reconstruction capability.

2. Design Principles

To synthesize an asymmetric transfer function on a single-layer metasurface, it is first necessary to recognize a critical constraint. Conventional dielectric metasurfaces composed of uniform-height nanopillars are inherently phase only modulation devices, in which the local transmission amplitude is determined by the geometric parameters and cannot be independently tuned without sacrificing efficiency. As noted above, quantitative phase reconstruction requires the transfer function to possess an asymmetric and monotonic response to ensure that positive and negative phase gradients yield distinct intensity outputs. In this work, the target transfer function is set as for the y-polarization channel as a monotonic asymmetric function of the spatial frequency kx:
H y ( k x ) = k x + k c 2 k c ,
where kc denotes the cutoff frequency of the system. This function is real-valued and nonnegative, increasing monotonically from 0 to 1 within the bandwidth. However, such amplitude modulation conflicts with the inherent phase-only nature of the metasurface. To resolve this contradiction, we use a double-phase encoding strategy that encodes amplitude information into the phase degrees of freedom.
For an arbitrary complex-amplitude distribution with amplitude A(x, y) and phase Φ(x, y), the following identity decomposition holds:
U ( x , y ) = A m a x 2 [ e i ( Φ + ψ ) + e i ( Φ − ψ ) ] .
Accordingly, the complex amplitude can be decomposed into a coherent superposition of two phase-only terms, Φ ± ψ. In this decomposition, the amplitude information is encoded in their phase difference 2ψ, while the phase information is carried by their average phase term. As depicted in Figure 1b, such decomposition inherently corresponds to a polar-coordinate mapping. Within this polar framework, the azimuthal axis stands for the phase Φ, ranging from 0 to 2π, and the radial axis denotes the normalized amplitude A/Amax, bonded within [0, 1]. For the real-valued target function adopted in this work (Φ = 0), the two phase-only terms simplify to a conjugate ±ψ, with ψ being a function of the spatial frequency kx.
Figure 1. (a) QPI setup based on a 4f system with the metasurface at the Fourier plane. (b) Conceptual illustration of double-phase encoding. (c) Polarization-multiplexed dual-channel operation.
The pair is implemented through the PB phase of a single-layer metasurface placed at the Fourier plane of the 4f system, so that each spatial frequency component kx passes through a region with its own in-plane rotation angle α(kx). As illustrated in Figure 1b, the light incident on the metasurface is x-polarized by the input polarizer and can be regarded as an equal-amplitude superposition of the LCP and RCP components, L =   ( x ^ +   i y ^ ) / 2 and R =   ( x ^ −   i y ^ ) / 2 . With each nanopillar acting as a half-wave plate whose fast axis is rotated by α, the Jones matrix in the linear basis reads
J α = c o s 2 α s i n 2 α   s i n 2 α − c o s 2 α
where a common phase is omitted. In the circular basis the same element is a phase only gate,
J ( α ) L = e ( + i 2 α ) R , J ( α ) R = e ( − i 2 α ) L ,
so that the two circular channels acquire opposite PB phases ±2α. These are exactly the two phase-only terms of Equation (2).
Writing the input as E 0 x ^ =   E 0 ( L + R ) / 2 , the field behind the metasurface becomes E = ( E 0 / 2 ) ( e ( − i ψ ) L + e ( + i ψ ) R ) , where
ψ   ≡   2 α
is the PB phase carried by each channel and, at the same time, the half-difference in the phases of the two terms in Equation (2). The two components are then recombined by two orthogonal linear analyzers:
E x = x ^ E = E 0 c o s ψ , E y = y ^ E = E 0 s i n ψ ,
so that the recorded intensities are Ix = I0cos2 ψ and Iy = I0sin2 ψ, which satisfy Ix + Iy = I0 for every α and independently of the object. Assigning the target transfer function of Equation (1) to the y-channel, Hy(kx) = sin ψ(kx), gives ψ = arcsin Hy and hence the rotation angle distribution
α ( k x ) = 1 2 arcsin ( k x + k c 2 k c ) ,
The y-polarized output implements the target transfer function Hy(kx), while the x-polarized channel naturally provides a complementary response cos ψ = ( 1 − H y 2 ) , satisfying energy conservation and serving as a reference channel to eliminate amplitude variations in the incident wavefront.
With the rotation angle distribution established as Equation (7), we proceed to optimize the meta-atom geometry for its physical implementation. The metasurface consists of crystalline silicon nanopillars on a silica substrate, with an operating wavelength of 800 nm. The unit cell structure is shown in Figure 2a, with a period of P = 400 nm and a height of H = 600 nm. The lengths of the nanopillar along the two principal axes (Wx and Wy) are scanned over the range of 100 nm to 250 nm. Figure 2c,d present the transmission coefficients for x- and y-polarized incidence, respectively. Based on the optimized data, the cross-polarization conversion efficiencies and phases are calculated and shown in Figure 2c and Figure 2h, respectively. The geometric parameters marked with asterisks, Wx = 223 nm and Wy = 133 nm, are selected for their high conversion efficiency. Figure 2b demonstrates that the phase shift ϕ of the optimized structure satisfies ϕ = 2α, in agreement with theoretical predictions. The selected nanopillars are spatially arranged according to α(kx), fully synthesizing the desired asymmetric transfer function on a single-layer metasurface.
Figure 2. (a) Unit cell schematic P = 400   n m , H = 600   n m . (b) Phase response vs. rotation angle satisfying ϕ = 2 α . (c,d) Transmission coefficients along the two principal axes vs. W x and W y . (e) Cross-polarization conversion efficiency with selected parameters W x = 223 nm, W y = 133 nm marked by the asterisk. (f,g) Transmission phases along the two principal axes vs. W x and W y . (h) Cross-polarization conversion phase.

3. Results

To verify the designed transfer function, full-wave FDTD simulations were performed on a metasurface with a 40-μm aperture. Figure 3a,d show the phase distributions under LCP and RCP incidence, respectively. Figure 3b,c present the simulated amplitude and phase responses of the x-polarized and y-polarized channels as functions of the transverse spatial frequency kx/k0, corresponding to the spatial frequency components in the equivalent 4f system. The cross-sectional profiles along the dashed lines are shown in Figure 3c,f. The y-polarized channel exhibits a monotonically increasing amplitude response with a nearly constant phase over the effective bandwidth, in good agreement with the design of Equation (1). The x-polarized channel shows a complementary monotonically decreasing amplitude response. Minor phase deviations are observed in the x-polarized channel at high spatial frequencies, but these deviations are negligible since the corresponding amplitude approaches zero in this region and thus does not affect the differentiation functionality. These simulation results confirm that the designed metasurface faithfully implements the desired asymmetric transfer function.
Figure 3. (a,d) Phase distributions under LCP and RCP incidence. (b,e) Amplitude and phase responses vs. k x / k c . (c,f) Cross-sectional profiles. The y-channel exhibits a monotonic increasing response; the x-channel shows a complementary decreasing response.
With the designed transfer function encoded on the metasurface at the Fourier plane of the 4f system, the incident field’s spatial frequency components are modulated by Hy(kx). Under the slowly varying phase approximation the local wavevector kx = φ′(x) stays inside the passband, |φ′| < kc, and the object is treated at each position as a local plane wave. Because Hy is linear in kx, the layer acts in the y channel as a first-order differentiator with a bias, and the field is
U y , out = 1 2 U i n − i k c ∂ x U i n .
With U i n = A e i φ , the intensity becomes
  I y = I 0 H y φ ′ 2 + A ′ 2 A k c 2 ,
where I0 = A2. For typical samples in microscopy with low absorption contrast, such as cells, the A′ term is negligible. Dropping it gives Equation (10):
I y ( x ) = I 0 φ ′ ( x ) + k c 2 k c 2 .
To eliminate the amplitude dependence, the complementary x-polarized channel is employed as a reference. The intensity ratio between the two channels is defined as
R ( k x ) = I y I y + I x ,
from which the phase gradient is retrieved as
φ ′ ( x ) = 2 k c R ( k x ) − k c .
Considering the discrepancy between the metasurface response and the theoretical prediction, plane waves with different spatial frequencies kx are employed to pre-calibrate the R(kx) curve, as shown in Figure 4a. The results demonstrate that R(kx) is almost linearly dependent on kx, which is consistent with the theoretical prediction and independent of the incident amplitude. For the effectiveness in eliminating the amplitude effect, see Appendix A. Therefore, the phase gradient can be unambiguously determined from the optical intensities Iy and Ix measured under two orthogonal polarization channels.
Figure 4. (a) R k x vs. k x with linear fitting. (b,e) Original and reconstructed phases of the “HIT” object. (c,d) Asymmetric differential images under x-polarization and y-polarization. (f) Measured gradient. (g) Ideal vs. measured gradient profiles along the black dashed line. (h) Original vs. reconstructed phase profiles along the white dashed line (RMSE = 0.111 rad, relative error 0.25%).
Once the phase gradient φ ′ ( x , y ) is obtained, the phase distribution φ ( x , y ) is reconstructed by solving the one-dimensional Poisson equation [29]
∂ 2 φ ∂ x 2 = ∂ φ ′ ∂ x   .
A single derivative fixes φ only up to an additive function of y, so the reconstruction needs a phase reference. We take the border of the reconstruction window as the zero of phase: it lies in the sample-free medium surrounding the object, and in a transmission measurement that medium defines the phase reference. Expanding in the sine basis of the window imposes exactly this condition, and the phase follows in closed form,
φ ( x , y ) = − ( L π ) 2 ∑ m = 1 L ∑ n = 1 L b m n ( m 2 + κ n 2 ) s i n ( π m x L ) s i n ( π n y L ) ,
where L is the size of the reconstruction window, bmn are the sine coefficients of ∂ φ ′ / ∂ x , and κ is a smoothing parameter set by the noise level of the measured gradient, vanishing for noise-free data. Equation (14) satisfies
∂ 2 φ ∂ x 2 + κ ∂ 2 φ ∂ y 2 = ∂ φ ′ ∂ x   ,
with a unique solution under the boundary condition above.
When the gradient data are noisy, the quadratic smoothing of Equation (15) is replaced by a sparsity prior on ∂ y 2 φ ,
min φ , ζ 1 2 ∂ x 2 φ − ∂ x φ ′ 2 2 + μ ∥ ζ ∥ 1 , s . t .   ζ = ∂ y 2 φ ,
where μ weights the prior and ζ is an auxiliary variable. Because the prior acts on ∂ y 2 φ , constant and linear-in-y offsets lie in its null space, and the phase reference remains the one fixed by Equation (14).
To verify the phase imaging performance of the proposed system, wavefront reconstruction simulations were performed in a 4f system with a numerical aperture (NA) of 0.1, the transfer functions being taken from the full-wave simulation of the metasurface, with amplitude and phase retained. The input phase object consists of three patterned letters (“H”, “I”, and “T”), as shown in Figure 4b, which possess different phase gradients with corresponding spatial frequencies ranging from 0.03k0 to 0.07k0, within the cutoff frequency range of the system. The differential intensity images output under the x-polarized and y-polarized channels are shown in Figure 4c,d. The two channels exhibit pronounced and complementary asymmetric features: the y-polarized channel produces a monotonic intensity gradient across each edge, with the bright and dark sides determined by the sign of the local phase gradient, while the x-polarized channel shows the opposite contrast. This complementary behavior directly reflects the monotonic asymmetric transfer function encoded on the metasurface, where positive and negative phase gradients are mapped to distinct intensity levels rather than being indistinguishable as in symmetric differentiators. Moreover, the differentiation directions of the two channels are opposite, which provides the necessary redundancy for eliminating the incident amplitude dependence and for retrieving the phase gradient without sign ambiguity. The phase gradient extracted based on the calibration curve R(kx) and the dashed comparison profiles are presented in Figure 4f and Figure 4g, respectively, verifying the accuracy of the gradient extraction. The extracted phase gradients and dashed-line comparison profiles are presented in Figure 4f,g, which verify the accuracy of the gradient extraction. The reconstructed phase distribution is shown in Figure 4e, demonstrating excellent consistency with the original phase. Figure 4h shows a quantitative comparison along the white dashed line, using the RMSE mean square error to describe the accuracy of quantitative reconstruction. RMSE can be calculated as follows:
R M S E = 1 M ⋅ N ∑ i = 1 M ∑ j = 1 N φ G T ( i , j ) − φ r e c ( i , j ) 2 ,
where M and N are the number of pixel rows and columns in the image, and are the values of the true phase and reconstructed phase at pixel positions (i, j), respectively. An RMSE of 0.111 radians and a relative error of 0.25% are obtained, further confirming the high accuracy of the proposed phase mapping strategy. In addition, since the placement of the metasurface on the Fourier plane requires precision, the sensitivity of the metasurface position placement was tested; details are given in Appendix B.
To evaluate the robustness of the reconstruction step, a complex-amplitude object with a donut-shaped amplitude and a Gaussian phase profile was employed, as shown in Figure 5a,b. Gaussian noise with a standard deviation of σ = 0.01 × 2π was added to the extracted phase gradient. The corresponding noise-added gradient is shown in Figure 5c,d. The reconstructed phase is presented in Figure 5e, and the profile comparison along the dashed line is shown in Figure 5f. For this object, the relative reconstruction error increases from 0.31% in the noise-free case at κ = 0 to 1.36% under σ = 0.01 × 2π with κ = 0.01. Despite this increase, the reconstructed profile remains highly consistent with the original one, indicating that the proposed system tolerates a realistic level of gradient noise without losing quantitative accuracy.
Figure 5. (a,b) Complex-amplitude object. (c) Added Gaussian noise ( σ = 0.01 × 2 π ). (d) Noise-added gradient. (e) Reconstructed phase after noise. (f) Original vs. noise-added reconstructed phase profiles (error 0.31–1.36%).
Meanwhile, to characterize the reconstruction behavior more systematically, numerical simulations were performed at the same noise level (σ = 0.01 × 2π) using different smoothing parameters κ, as shown in Figure 6a. The error reaches its minimum at κ = 0.01, where the relative error decreases from 4.48% at κ = 0 to 1.36%, corresponding to a 3.8-fold improvement. This behavior reflects the trade-off inherent in total-variation regularization: a small but nonzero κ suppresses high-frequency noise in the gradient data, whereas an excessively large κ over-smooths the phase profile and reintroduces reconstruction error. Moreover, the benefit of regularization becomes more pronounced as the noise level increases, as shown in Figure 6b. At κ = 0, the RMSE grows almost linearly with σ, indicating that the reconstruction is essentially noise-limited. In contrast, at κ = 0.01, the variation in the RMSE with σ is nearly flat over the tested range, which indicates that the reconstruction process possesses an inherent degree of robustness to noise and that the regularization effectively decouples the reconstruction accuracy from the noise level.
Figure 6. (a) RMSE versus the smoothing weight κ of the one-dimensional Poisson reconstruction at σ. (b) Reconstructed RMSE versus the gradient-noise level σ.
To include the detection chain, photon and readout noise are added to the two intensities of the object of Figure 5 and carried through the same reconstruction. At 50 dB the reconstruction error is 1%, i.e., the order of magnitude of the accuracy of noise-free reconstruction when κ = 0.01, so that the detection chain no longer limits the reconstruction. The detector model, the propagation of both noise terms, and the reconstructions at 30, 40 and 50 dB are given in Appendix C.

4. Discussion

The results show that one dielectric layer at the Fourier plane of a 4f system converts a phase gradient into a calibrated intensity ratio, and that the phase follows from that ratio by integration. The response is monotonic and almost linear in the gradient over the effective passband, so the ratio is single-valued in the gradient and preserves its sign.
The amplitude of the response is carried by the relative phase of two conjugate terms, as in double-phase encoding, so a layer that controls only phase sets the two field amplitudes at cos ψ and sin ψ, with H = sin ψ in the y channel and its complement in the x channel. Because the two intensities sum to the incident intensity, the ratio is free of the incident amplitude, and the reference that the measurement needs is supplied by the encoding itself.
The reconstruction handles noise through one smoothing parameter. A small nonzero value suppresses the high-frequency part of the gradient noise, an excessive one over-smooths the phase, and the reconstruction error accordingly falls to a minimum at an intermediate value. Set from the noise level of the measured gradient, the parameter keeps the error nearly flat as the noise grows, and the smoothing leaves in place the phase reference fixed by the boundary condition.
Relative to the asymmetric schemes discussed above, the difference lies in the range over which the readout stays quantitative. In [23,25] the calibration is established in the weak-phase approximation, and in [24] the asymmetric filter yields phase contrast rather than a phase map. Here the gradient is inverted from R(kx) and integrated, so the phase obtained is quantitative and not confined to weak phase. The encoding is the double-phase encoding of [17], applied there to qualitative image processing; the present scheme extends it to quantitative phase imaging.
The scheme currently measures one projection of the phase gradient. Extending the measurement to two gradient directions would require a second independent response, which could be achieved in future work by reusing additional degrees of freedom such as polarization or wavelength. Such an extension would render the reconstruction fully two-dimensional.

5. Conclusions

In conclusion, we proposed and numerically demonstrated a compact QPI scheme based on a single-layer PB metasurface. Double-phase encoding achieves amplitude modulation by means of pure phase modulation, encoding the amplitude response required by an asymmetric transfer function into the phase degrees of freedom and thereby synthesizing a strictly monotonic asymmetric complex-amplitude transfer function on a single-layer all-dielectric metasurface; this transfer function establishes an unambiguous, approximately linear correspondence between phase gradient and output intensity, fundamentally removing the sign ambiguity of symmetric differentiators and enabling reliable discrimination between positive and negative phase gradients. Circular-polarization multiplexing supplies a complementary channel in the same layer, and the ratio of the two channel images removes the influence of incident amplitude; a total-variation-regularized one-dimensional Poisson integration then quantitatively reconstructs the phase from the gradient. Full-wave simulations verify the monotonicity and linearity of the transfer function and achieve high-fidelity reconstruction with a relative error of 0.3–1.4% in an equivalent 4f system, together with favorable robustness to gradient noise. Because the response is written analytically into a single dielectric layer, this scheme offers a scalable and compact route toward quantitative phase microscopy with potential in biological imaging and transparent sample detection.

Author Contributions

Conceptualization, Y.Z. and Y.L. (Yan Li); methodology, Y.Z.; software, K.C. and W.N.; validation, K.C.; formal analysis, Y.Z.; investigation, Y.Z. and K.C.; resources, Y.L. (Yan Li) and Y.L. (Yi Liu); data curation, Y.Z.; writing—original draft preparation, Y.Z.; writing—review and editing, Y.L. (Yan Li); visualization, W.N.; supervision, Y.L. (Yan Li); project administration, Y.L. (Yan Li); funding acquisition, Y.L. (Yan Li) and Y.L. (Yi Liu). All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Natural Science Foundation of China (12274103, 62475060); Taishan Scholar Foundation of Shandong Province (tsqn202312140); and Key Technology Research and Development Program of Shandong Province (2024TSGC0727).

Data Availability Statement

Data will be made available on request.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
QPIQuantitative phase imaging
PBPancharatnam–Berry
LCPLeft circular polarization
RCPRight circular polarization
FDTDFinite-difference time-domain
NANumerical aperture
RMSERoot-mean-square error

Appendix A

The phase was fixed at the object of Figure 5 with 20 rad peak and only the amplitude was changed. Four non-uniform amplitudes were used, with an envelope from 1.0 down to 0.95, 0.90, 0.80 and 0.60, and random variation of 2%, 5%, 8% and 20%, as shown in Figure A1a–d. The phase profiles in Figure A1e coincide for the four levels. The phase RMSE is 0.066, 0.066 and 0.065 rad at the 2%, 5% and 8% levels, close to the 0.067 rad obtained with a uniform amplitude, and rises to 0.083 rad at 20%. With a constant phase the same four amplitudes give 0.004, 0.009, 0.016 and 0.056 rad RMSE, as shown in Figure A1f, which isolates the contribution of the amplitude. That contribution produces no measurable change in the retrieved phase up to the 8% level and adds 0.02 rad at 20%, meaning that the amplitude change only just reaches a non-negligible level at this point. These results show that the amplitude non-uniformity has a minor effect on the retrieved phase.
Figure A1. Non-uniform amplitude of increasing degree and the reconstructed phase. (a–d) Amplitude with an envelope from 1.0 down to 0.95, 0.90, 0.80 and 0.60 and random variation of 2%, 5%, 8% and 20%. (e) Phase profiles along y = 0, where the dashed line is the object. (f) Phase RMSE for the same four amplitudes with a constant phase.
The width of the same phase object was varied while the peak phase stayed at 20 rad, which sweeps the steepest gradient from 0.10 to 0.88 kc. The phase RMSE stays at 0.08 to 0.13 rad up to 0.65 kc, rises to 0.14 rad at 0.79 kc and to 0.53 rad at 0.88 kc. As shown in Figure A2, before 0.8 kc, the phase reconstruction accuracy is relatively high and the error remains stable. The error increases only near the passband edges, because the calibration curve R(kx) measured there tends to flatten out.
Figure A2. Phase RMSE against the maximum phase gradient. The peak phase is 20 rad and the width of the object is varied so that the steepest gradient runs from 0.10 to 0.88 kc.

Appendix B

The metasurface defines the transfer function in the spatial-frequency domain, so its placement on the Fourier plane sets the spatial-frequency axis of the measurement. To quantify the sensitivity of the reconstruction to this placement, the layer was displaced in three directions and the reconstruction chain of Figure 4 was repeated with the simulated response of the device. Figure A3 shows the corresponding reconstructions. The three directions act differently. A displacement along x translates the transfer function by Δkx = (2Δx/D)kc, where D = 40 μm is the aperture, and adds a constant offset to the retrieved gradient, 0.039 rad/μm at Δx = 1 μm. Because the reconstruction acts on the derivative of the gradient, this constant part does not propagate, and the remaining RMSE increment grows from 0.019 rad at 1% of the passband to 0.097 rad at 5%. A displacement along y does not change the transfer function itself, since the synthesized response is invariant along y, and only trims the aperture; the increment is 0.001 and 0.016 rad at 5% and 12.5% clipping, and 0.132 rad at 25%. A displacement along z adds a quadratic phase at the layer that is common to the two polarization channels and largely cancels in their ratio, so the increment is 0.017, 0.035 and 0.086 rad for 10, 20 and 50 μm. Over the ranges considered the increment remains below 0.1 rad except for the largest clipping along y, which can be attributed to the relatively large 25% aperture clipping. The placement is therefore most sensitive to the transverse position along x and to the axial position, and least sensitive to a displacement along y.
Figure A3. Reconstruction results for different translation displacements along (a) the x-direction, (b) the y-direction and (c) the z-direction. The numbers in the lower-right corner are the RMSE increments of the reconstruction results relative to zero mismatch.

Appendix C

The detector follows the sCMOS model [30], in which the value of pixel p is
Z p = γ p   P o i s   S p   + N 0 ,   σ R + β p
where Sp = I·N is the number of photoelectrons collected by the pixel of normalized intensity I, N is the full well, γp its gain, βp its offset and σR the readout noise. The gain and offset maps are taken as uniform (γp = 1, βp = 0) and σR = 2 e−; dark current and quantization noise are neglected. The Poisson term is simulated exactly; above a few photons per pixel it is Gaussian to better than 1%, so it enters the propagation through its variance alone:
σ 2 I   =   a I   +   b   ,   a   = 1 N ,   b   =   σ R N 2
The two channels are read independently, so their noises are uncorrelated. The camera SNR is defined in the shot-noise limit as SNR = 10 log10 N, so that 40 dB corresponds to 104 electrons per pixel. Both terms through the intensity ratio of Equation (9) gives
σ R 2 = I x 2 σ 2 I y + I y 2 σ 2 I x 4   R 2   I y + I x 4  
and the gradient noise follows from the local slope of the calibration curve of Figure 4a. Fixed-pattern noise is not simulated; dark current, quantization, saturation and inter-channel crosstalk are neglected.
Figure A4 shows the reconstruction at 30, 40 and 50 dB (103, 104, 105 electrons per pixel) with 2 e− readout, together with profiles. The relative error is 9.3%, 2.0% and 1.0%, against 0.94% for noise-free data processed with the same reconstruction at κ = 0.01. The residual at 50 dB is the bias of the regularization rather than a noise floor: the noise-free error at κ = 0 is 0.31%.
Figure A4. Reconstructed phase of the object of Figure 5 at camera SNRs of (b) 30, (c) 40 and (d) 50 dB with 2 e− readout; (a) ground truth. (e–g) Profiles along the dashed line: original (light blue) and reconstruction (orange dashed).

References

  1. Park, Y.; Depeursinge, C.; Popescu, G. Quantitative phase imaging in biomedicine. Nat. Photonics 2018, 12, 578–589. [Google Scholar] [CrossRef] [Scilit]
  2. Edwards, C.; Arbabi, A.; Popescu, G.; Goddard, L.L. Optically monitoring and controlling nanoscale topography during semiconductor etching. Light Sci. Appl. 2012, 1, e30. [Google Scholar] [CrossRef] [Scilit]
  3. Chaumet, P.C.; Bon, P.; Maire, G.; Sentenac, A.; Baffou, G. Quantitative phase microscopies: Accuracy comparison. Light Sci. Appl. 2024, 13, 288. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Kossowski, N.; Tahmi, Y.; Loucif, A.; Lepers, M.; Wattellier, B.; Vienne, G.; Khadir, S.; Genevet, P. Metrology of metasurfaces: Optical properties. npj Nanophotonics 2025, 2, 5. [Google Scholar] [CrossRef] [Scilit]
  5. Kurata, R.; Toda, K.; Ishigane, G.; Naruse, M.; Horisaki, R.; Ideguchi, T. Single-image phase retrieval for off-the-shelf Zernike phase-contrast microscopes. Opt. Express 2024, 32, 2202–2211. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Rogalski, M.; Arcab, P.; Wdowiak, E.; Picazo-Bueno, J.; Micó, V.; Józwik, M.; Trusiak, M. Hybrid Iterating-Averaging Low Photon Budget Gabor Holographic Microscopy. ACS Photonics 2025, 12, 1771–1782. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Primot, J. Theoretical description of Shack–Hartmann wave-front sensor. Opt. Commun. 2003, 222, 81–92. [Google Scholar] [CrossRef] [Scilit]
  8. Wu, X.; Huang, L.; Gu, N. Enhanced-resolution Shack–Hartmann wavefront sensing for extended objects. Opt. Lett. 2023, 48, 5691–5694. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Chen, T.; Li, X.; Hu, Z.-D.; Wu, J.; Wang, J. Metasurface-enabled grafted perfect vector vortex beams with trigonometric-function topological charges for high-capacity optical encryption. Opt. Lett. 2025, 50, 4214–4217. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Feng, S.; Wang, Y.; Hu, Z.-D.; Wang, J.; Wang, X.; Li, M.; Ding, D.; Zhang, F.; Khakhomov, S. Measurement of microwave meta-quaternion vortex arrays enabling Luoshu-WeightLock imaging encryption. Photon. Res. 2025, 13, 2065–2072. [Google Scholar] [CrossRef] [Scilit]
  11. Sulejman, S.B.; Wesemann, L.; McCormack, M.; Meng, J.; Hutchison, J.A.; Priscilla, N.; McColl, G.; Read, K.; Sim, W.; Sukhorukov, A.A.; et al. Metasurfaces for Infrared Multimodal Microscopy: Phase Contrast and Bright Field. ACS Photonics 2025, 12, 1494–1506. [Google Scholar] [CrossRef] [Scilit]
  12. Zhou, J.; Qian, H.; Zhao, J.; Tang, M.; Wu, Q.; Lei, M.; Luo, H.; Wen, S.; Chen, S.; Liu, Z. Two-dimensional optical spatial differentiation and high-contrast imaging. Natl. Sci. Rev. 2021, 8, nwaa176. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Zhou, J.; Wu, Q.; Zhao, J.; Posner, C.; Lei, M.; Chen, G.; Zhang, J.; Liu, Z. Fourier Optical Spin Splitting Microscopy. Phys. Rev. Lett. 2022, 129, 020801. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Wang, X.; Wang, H.; Wang, J.; Liu, X.; Hao, H.; Tan, Y.S.; Zhang, Y.; Zhang, H.; Ding, X.; Zhao, W.; et al. Single-shot isotropic differential interference contrast microscopy. Nat. Commun. 2023, 14, 2063. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Li, L.; Jia, W.; Jin, C.; Wang, S.; Shen, Z.; Yang, Y. Single-Shot Wavefront Sensing with Nonlocal Thin Film Optical Filters. Laser Photonics Rev. 2023, 17, 2300426. [Google Scholar] [CrossRef] [Scilit]
  16. Wu, Q.; Zhou, J.; Chen, X.; Zhao, J.; Lei, M.; Chen, G.; Lo, Y.-H.; Liu, Z. Single-shot quantitative amplitude and phase imaging based on a pair of all-dielectric metasurfaces. Optica 2023, 10, 619–625. [Google Scholar] [CrossRef] [Scilit]
  17. Yu, L.; Singh, H.J.; Pietila, J.; Caglayan, H. Double-phase metasurface operators for all-optical image processing. Light Sci. Appl. 2026, 15, 119. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Qiu, X.; Zhang, J.; Fan, Y.; Zhou, J.; Chen, L.; Tsai, D.P. Metasurface enabled high-order differentiator. Nat. Commun. 2025, 16, 2437. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Fu, W.; Zhao, D.; Li, Z.; Liu, S.; Tian, C.; Huang, K. Ultracompact meta-imagers for arbitrary all-optical convolution. Light Sci. Appl. 2022, 11, 62. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Bi, X.; Guo, X.; Wu, X.; Fan, X.; Wei, B.; Wen, D.; Liu, S.; Zhao, J.; Li, P. Wideband optical edge detection based on dielectric metasurface. Appl. Phys. Lett. 2023, 123, 061702. [Google Scholar] [CrossRef] [Scilit]
  21. Sardana, J.; Devinder, S.; Kaassamani, S.; Zhu, W.; Agrawal, A.; Joseph, J. Polarization Specific Edge Enhancement Enabled by Compact Dielectric Metasurface Imaging System. ACS Photonics 2025, 12, 2380–2388. [Google Scholar] [CrossRef] [Scilit]
  22. Zhang, Y.; Lin, P.; Huo, P.; Liu, M.; Ren, Y.; Zhang, S.; Zhou, Q.; Wang, Y.; Lu, Y.-q.; Xu, T. Dielectric Metasurface for Synchronously Spiral Phase Contrast and Bright-Field Imaging. Nano Lett. 2023, 23, 2991–2997. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Liu, J.; Wang, H.; Li, Y.; Tian, L.; Paiella, R. Asymmetric metasurface photodetectors for single-shot quantitative phase imaging. Nanophotonics 2023, 12, 3519–3528. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. Priscilla, N.; Wesemann, L.; Clark, L.; Sulejman, S.B.; Rickett, J.; Davis, T.J.; Roberts, A. Rapid inverse design of metasurfaces with an asymmetric transfer function for all-optical image processing using a mode matching model. Opt. Express 2024, 32, 26964–26978. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Ji, A.; Song, J.-H.; Li, Q.; Xu, F.; Tsai, C.-T.; Tiberio, R.C.; Cui, B.; Lalanne, P.; Kik, P.G.; Miller, D.A.B.; et al. Quantitative phase contrast imaging with a nonlocal angle-selective metasurface. Nat. Commun. 2022, 13, 7848. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. Kwon, H.; Arbabi, E.; Kamali, S.M.; Faraji-Dana, M.; Faraon, A. Single-shot quantitative phase gradient microscopy using a system of multifunctional metasurfaces. Nat. Photonics 2020, 14, 109–114. [Google Scholar] [CrossRef] [Scilit]
  27. Chen, H.; Yang, Q.; Chen, S.; Shu, W.; Luo, H. Dynamic phase reconstruction enabled by an integrated operational metasurface. Appl. Phys. Lett. 2025, 127, 191102. [Google Scholar] [CrossRef] [Scilit]
  28. Yang, Q.; Shou, Y.; Zhao, Y.; Liu, J.; Chen, S.; Shu, W.; Wen, S.; Luo, H. Multimodal phase microscopy via differential metasurface. APL Photonics 2026, 11, 026104. [Google Scholar] [CrossRef] [Scilit]
  29. Matías Di Martino, J.; Flores, J.L.; Pfeiffer, F.; Scherer, K.; Ayubi, G.A.; Ferrari, J.A. Phase retrieval from one partial derivative. Opt. Lett. 2013, 38, 4813–4816. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Mandracchia, B.; Hua, X.; Guo, C.; Son, J.; Urner, T.; Jia, S. Fast and accurate sCMOS noise correction for fluorescence microscopy. Nat. Commun. 2020, 11, 94. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.