Review Reports
- Xingyi Li 1,2,
- Peixuan Wu 1 and
- Yaoguang Ma 1,*
- et al.
Reviewer 1: Sai Chen Reviewer 2: Anonymous Reviewer 3: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsIssues in the Article:
-
Line 77: The abbreviation "SWAP" for 'size,weight and power' is not defined, nor is it explained at the end of the article.
-
Line 164: "A quasi-achromatic approach based on folding the group delay in the time domain can be employed." How does the "time-domain group delay folding method" address the issue of excessive group delay? Could this be further explained?
-
Line 189: "angle" should be plural, "angles."
-
Line 190: "numerial" is misspelled and should be "numerical."
-
Line 189: "aperture" should be plural, "apertures."
-
Table 1: Spectral range (nm): 435-656. Should this be consistent with the 430-650 nm mentioned in the abstract?
-
Line 245: "It is noted that the PSF remains small across all wavelengths, ensuring high imaging resolution." Are there quantitative metrics to support the term "small"?
-
Line 259: "UVISEL" appears for the first time and should be defined. It is also not explained at the end of the article.
-
Line 314: "The presented theory and design framework are expected to accelerate the adoption of HRMS in practical applications." The core contribution of the article is the "HRMS design method combining ray-tracing and full-wave simulation," not new fundamental optical theory. The term "presented theory" conflates "method" with "theory."
Author Response
|
Comments 1: Line 77: The abbreviation "SWAP" for 'size,weight and power' is not defined, nor is it explained at the end of the article. |
|
Response 1: We thank the reviewer for this constructive comment. We agree that defining the acronym is necessary for clarity. In the revised manuscript, we have now defined "SWaP" as "sze, weight, and power" upon its first appearance in the line 82 and added the correspond abbreviation at the end of the article.
|
|
Comments 2: Line 164: "A quasi-achromatic approach based on folding the group delay in the time domain can be employed." How does the "time-domain group delay folding method" address the issue of excessive group delay? Could this be further explained? |
|
Response 2: We appreciate the reviewer's inquiry regarding this point. This approach is based on the fundamental principle of the temporal periodicity inherent in the group delay. To manage this periodicity, the group delay can be folded by the frequency difference. This clarification has been added to the text on line 178 as “By folding the group delay with respect to the frequency difference, the requirement on its range is relaxed, thereby enabling achromatic performance across a broader bandwidth.”. For a comprehensive treatment of the methodology, we direct the reviewer to Reference [23].
Comments 3-5: Line 189: "angle" should be plural, "angles. " Line 190: "numerial" is misspelled and should be "numerical." Line 189: "aperture" should be plural, "apertures. " Response 3-5: We thank the reviewer for their careful reading and valuable comments on our manuscript. We have thoroughly proofread the entire text and corrected all grammatical errors and typos we found, including but not limited to those specifically pointed out. These revisions have significantly improved the clarity and quality of our manuscript.
Comments 6: Table 1: Spectral range (nm): 435-656. Should this be consistent with the 430-650 nm mentioned in the abstract? Response 6: The authors appreciate the reviewer's comment regarding this point. This two wavelength range should be the same, we correct the wavelength in the abstract to 435-656 nm which is same as the design.
Comments 7: Line 245: "It is noted that the PSF remains small across all wavelengths, ensuring high imaging resolution." Are there quantitative metrics to support the term "small"? Response 7: We thank the reviewers for their valuable comments and constructive suggestions. We agree that it is essential to include quantitative metrics of the PSF to better demonstrate the imaging quality. The RMS size of the PSF has been added in line 278 “It is noted that the RMS diameters of the PSF at five wavelengths are 2.71μm, 2.43μm, 2.74μm, 2.68μm and 2.46μm, which remain small across all wavelengths, ensuring high imaging resolution.”
Comments 8: Line 259: "UVISEL" appears for the first time and should be defined. It is also not explained at the end of the article Response 8: We thank the reviewer for pointing out this issue. The UVISEL is the type of a spectroscopic ellipsometer from HORIBA Scientific, the authors add the company name before it to avoid misunderstanding. The line 293 in the text has been updated as below: “The refractive index of the film, measured by spectroscopic ellipsometry (HORIBA Scientific UVISEL), is 2.32 at the central wavelength of 550 nm.” |
Reviewer 2 Report
Comments and Suggestions for AuthorsThe manuscript of Xingyi Li et al. presents an interesting study of the hybrid refractive-metalens system for making compact wide field-of-view broadband lenses for image projection. Thanks to the synergy of ray-tracing and full-wave simulations the authors show a compelling methodology to co-optimize the system with reduced optical path length by 29 % as compared to a fully refractive system for 35 deg field-of-view correction. The results of the hybrid system simulations are supported by the experimental validation of the image projection without significant image distortion. Although, some points within the manuscript have to be improved.
- The authors compare the final HRMS device incorporating a metasurface and 5 spherical lenses with an 8-lens all-refractive system (4 spherical and 4 aspherical lens) in terms of total track length (TTL). It would be helpful to discuss why the all-refractive reference system would be a standard one, and why it was chosen as a comparator. Although, the authors say the TTL reduction would be limited in the case of the aspherical lens utilization only, the fairness of the presented comparison should be clearly highlighted.
- To apprehend fully the importance of the metalens structure in the co-optimized hybrid system, it would be helpful to provide MTF data for the refractive device with the TTL equivalent to HRMS.
- Although, the authors mention that the hybrid refractive-metalens approach have been typically addressed in the infrared range the current disadvantages of such systems remain overlooked. A comparative table of the shown HRMS device results with state-of-the-art hybrid systems (metalens size, NA, focusing efficiency, aberration corrections, wavelength range, etc.) would be necessary. Some relevant papers can be supplemented to fully demonstrate the research progress (including - Nat Commun11, 3892 (2020); - Nano Lett. 2025, 25, 20, 8103–8109).
- The utilized shapes are primarily circles, hexagons or squares that exhibit symmetry and independence on polarization of incident light, as well as the manufacturing ease is highlighted. Although, such metalens systems are easily comparable to diffractive lens operation options, would it be possible to incorporate more complex compound meta-atoms for the design framework to further enhance wide field-of-view imaging performance or chromatic aberration correction?
- The design method of the phase surface for co-optimization in ZEMAX is noted to omit the diffraction efficiency and influence of higher orders of the metalens. Would it be possible to define the limit of the metalens focusing efficiency, when this assumption could not be viable for the design applicability?
- 2b shows the dependence of meta-atom phase, transmittance, and group delay. However, there is no lateral meta-atom size values, making the graph clarity rather vague. Remaking this graph as panels of corresponding data versus meta-atom size would be helpful. Addressing this comment could also better reveal the manufacturing complexity, including lateral meta-atom geometries of nanopillars used for the experimental fabrication of the optical device.
- The final HRMS device yield a focal shift of 2 um. Although, the value is negligible as compared to the effective focal length, a comparison to the depth of focus (Rayleigh length), g. at the wavelength of the band center, is needed to confirm that the optical system is free of chromatic blur.
- The manuscript contains some typos or unexplained acronyms (e.g. SWAP) which should be fixed.
Author Response
Please see the attached file
Author Response File:
Author Response.pdf
Reviewer 3 Report
Comments and Suggestions for AuthorsThis paper proposes a hybrid refraction-superlens (HRMS) system design method that combines ray tracing and full-wave simulation. It achieves wide field of view and high-resolution imaging in the visible light band and significantly shortens the total length of the optical system. This method effectively corrects aberrations and improves the integration and imaging quality of the system by reasonably distributing the functions of refractive elements and superlenses. If the rigor and depth of the format can be further improved, this paper will be more persuasive in terms of method innovation and system verification, for example:
1. Expanding the specific mechanism of the superlens in the system. Although the paper mentions that the superlens is used for "aberration correction" and "dispersion compensation", it can further specifically explain its complementary mechanism with traditional refractive lenses in aberration correction, especially the phase control strategy under wide-angle incidence.
2.The experimental data and comparisons can be more comprehensive. The imaging effects and MTF measurement results shown in Figures 5(e) and 5(f) are good, but they lack direct comparison data with pure refractive systems or single superlens systems (such as efficiency, distortion, chromatic aberration, etc.), and it is recommended to discuss this part to highlight the advantages of HRMS.
3.Expanding the discussion on the potential of computational optics assistance. The paper mentions that "neural networks can be used for image enhancement", and it can be appropriately discussed on how to combine computational optical methods (such as point spread function engineering or semantic imaging) to further improve system performance, highlighting the innovation of interdisciplinary methods.
Author Response
|
Comments 1: Expanding the specific mechanism of the superlens in the system. Although the paper mentions that the superlens is used for "aberration correction" and "dispersion compensation", it can further specifically explain its complementary mechanism with traditional refractive lenses in aberration correction, especially the phase control strategy under wide-angle incidence. |
|
Response 1: We thank the reviewer for this insightful comment. We have expanded the design section to clarify the complementary mechanism. The key points are: Chromatic Correction: The metalens is designed with negative dispersion to directly counteract the positive dispersion of the refractive lens, enabling effective broadband chromatic aberration compensation. Wide-Angle Performance: The metalesn provides unparalleled phase control freedom, allowing us to engineer a phase profilethat simultaneously compensates for both chromatic and field-dependent aberrations under wide-angle incidence, going beyond the limitations of conventional optics. The corresponding revisions can be found in line 88-95, we have added the following text: “On the one hand, for chromatic aberration correction, because the metalens and the refractive lens possess opposite dispersion characteristics which enabling effectively counteracts the axial chromatic aberration introduced by the refractive lens. On the other hand, for addressing off-axis aberrations (e.g., coma, astigmatism) induced by wide-angle incidence, the metasurface offers unparalleled phase control freedom. Its phase profile can be precisely designed as a function of position, wavelength, and the angle of incidence, enabling the simultaneous synthesis of a phase front that compensates for large-angle aberrations.”
Comments 2: The experimental data and comparisons can be more comprehensive. The imaging effects and MTF measurement results shown in Figures 5(e) and 5(f) are good, but they lack direct comparison data with pure refractive systems or single superlens systems (such as efficiency, distortion, chromatic aberration, etc.), and it is recommended to discuss this part to highlight the advantages of HRMS. Response 2: The authors appreciate the reviewer's comments on the imaging results of the HRMS. The authors have provided the MTF data of a widely used refractive lens with equivalent specifications, which is comparable to that of the hybrid refractive–metasurface lens. It is worth noting, however, that this refractive lens consists of three aspherical and four spherical lens elements, with a total length of 31.5 mm. Both its structural complexity and physical size exceed those of the hybrid lens. As for a pure metasurface lens, achieving achromatic performance at such a high pixel resolution is extremely challenging and is nearly unfeasible with current fabrication capabilities. In response to the reviewer’s comment, the authors have included the MTF values of the refractive lens in Figure 4 and added corresponding explanations in line 267 “For comparison, the MTF of the refractive lens is presented in Fig. 4d, showing nearly identical performance to the HRMS lens. However, to correct aberrations at the peripheral field of view, the refractive design requires a longer optical path, resulting in a greater total lens length.”.
Comments 3: Expanding the discussion on the potential of computational optics assistance. The paper mentions that "neural networks can be used for image enhancement", and it can be appropriately discussed on how to combine computational optical methods (such as point spread function engineering or semantic imaging) to further improve system performance, highlighting the innovation of interdisciplinary methods. Response 3: We thank the Reviewer for this valuable suggestion. The relevant content has been added on line 331 introducing the methods of neural networks for enhancing image quality. “The integration of computational optics presents a significant opportunity for performance enhancement. For instance, the PSF of the HRMS can be characterized across the field of view. A neural network can then be employed to perform spatially variant deconvolution, leveraging the estimated PSF to restore image clarity and compensate for residual aberrations across the entire image, even without a co-designed optical encoder…” |