Abstract

Ultrasonic time-of-flight (TOF) is sensitive to the temperature along its propagation path, which offers a non-intrusive route to sense the thermal state inside solid structures. However, existing ultrasonic thermometry methods mostly rely on a dual-measurement strategy (TOF + boundary temperature) and lack a theoretical basis for inverting heat flux from a single TOF sequence alone. This paper establishes a thermo-acoustic measurement model incorporating thermal expansion correction and proves that, under one-dimensional transient heat conduction, a single TOF sequence is sufficient to recover both the surface heat flux and the internal temperature field without ambiguity. To solve the resulting inverse problem, we implement a conjugate-gradient algorithm regularized by the Morozov discrepancy principle as the stopping rule. Numerical validation under five heat flux profiles shows that the reconstruction error (NRMSE) stays below 0.65% with noise-free input data. More importantly, when realistic noise levels are introduced—specifically ±1 ns TOF jitter and ±2.5 °C temperature uncertainty, consistent with our instrument specifications—the single-TOF approach (M1) achieves NRMSE values between 9.8% and 24.2%, markedly below the hard-Dirichlet dual-measurement scheme (M2, using both TOF and boundary temperature, 88.7–155.6%) at the same noise point. We attribute this large gap to the different ways each noise source enters the inversion: TOF perturbations are effectively damped by the soft-constraint formulation and the discrepancy criterion, while boundary temperature errors are imposed as a Dirichlet hard constraint and therefore propagate directly into the estimated state field. The method is further applied to a flat plate heating experiment on 20# steel, in which the reconstructed heat flux is fed back through the forward conduction model and the resulting temperature history is compared against four thermocouples not used in the inversion. The reconstructed temperature field matches four embedded thermocouples within 2.58 °C RMS.

1. Introduction

The surface heat flux and internal temperature distribution of structures are core measurement objects of common concern in thermal testing, thermal qualification, thermal protection design, and thermal management operation [1,2,3,4]. There is a strong demand for non-intrusive, continuous measurement in fields such as aircraft thermal protection [5], industrial heating [6], battery thermal management [7,8] and engine component testing [9].
However, the most commonly used methods, such as thermocouples and heat flux meters, have inherent limitations [5,10,11]: thermocouples require hole drilling and embedding, providing only discrete temperature measurement points and disturbing the local thermal boundary; heat flux meters (such as calorimetric or thin-film types) need to be installed on the heated surface, directly interfering with the measured thermal boundary, and most require auxiliary systems such as water cooling, limiting their use in harsh thermal environments. More importantly, contact methods can only measure local quantities on the boundary. It is difficult to cover the surface heat flux with measurement points in space and achieve non-invasive, uninterrupted continuous measurement in time. These limitations have motivated research on non-intrusive transient temperature and heat flux measurement methods.
Ultrasonic detection provides a feasible route [12,13,14]. The propagation speed of ultrasonic waves in solids varies with temperature, so the time-of-flight (TOF) of ultrasonic waves passing through a high-temperature structure and reflecting from one end carries temperature integral information along the acoustic path. In the echo mode, the transceiver probe sits on the opposite side of the heated surface, without penetrating the structure or disturbing the thermal boundary. The configuration is naturally suitable for online monitoring.
Inverting surface heat flux and the internal temperature field from TOF is a severely ill-posed inverse heat conduction problem (IHCP) [15,16], where measurement noise is amplified into spurious heat flux structures, and the form and quality of measurement information fundamentally determine the feasibility and accuracy of inversion. Within the heat transfer inverse problem framework, ultrasonic TOF inversion has evolved from temperature field reconstruction to heat flux identification. Wang [13] first proposed the idea of using ultrasonic reflection signals to invert internal temperature distribution and heat flux in solids. Ihara et al. [17,18] verified the measurability of temperature profiles through ultrasonic pulse-echo experiments. Wei et al. [19] established a forward-inverse method for reconstructing internal temperature distribution from ultrasonic measurements. Building on this, Zhu Liyan et al. [20] provided uniqueness theory for multi-parameter identification in a thermo-acoustic–solid coupling framework, but their proof relied on additional measurements such as boundary temperature. The above work collectively verified the feasibility of the TOF inversion route, but most relied on a dual-measurement strategy of TOF plus temperature [19,21], adding system complexity, and none provides a theoretical basis for inverting heat flux from a single TOF sequence alone.
This brings us to a foundational question. In inverse problem theory, solution uniqueness is the foundation of measurement methods: if two different heat flux histories produce identical TOF signals, no algorithm can distinguish them. However, the uniqueness of the mapping from a single TOF sequence to heat flux has not been rigorously proved. Existing uniqueness results require introducing additional measurements (such as boundary temperature) or rely only on numerical experience rather than proof. In addition, existing inversions all ignore the effect of thermal expansion on the acoustic path. Even in the medium-low temperature range, the acoustic path change caused by thermal expansion produces a systematic time shift comparable to or several times larger than the instrument jitter. Ignoring it will incorrectly interpret this systematic time shift as a temperature/heat flux signal, with deviation accumulating over time.
The principal contributions of this work are threefold. First, we provide a rigorous uniqueness result for the expansion-corrected thermo-acoustic forward map within the one-dimensional, constant-property class—a result that, to our knowledge, has not appeared in the ultrasonic heat flux measurement literature. Second, we develop a matched regularization scheme (CGM with the Morozov discrepancy principle) that renders the ill-posed inverse problem practically solvable from a single TOF channel, without recourse to a back-wall thermocouple. Third, we demonstrate the method end-to-end on a physical flat plate experiment, providing an independent temperature-field consistency check and an explicit uncertainty budget that quantifies the operating envelope of the technique. Together, these contributions position single-channel ultrasonic TOF as a viable candidate for surface heat flux monitoring in scenarios where sensor count, wiring, or harsh-environment survivability constrain the deployment of multi-point thermocouple arrays.
The remainder of the paper is organized as follows. Section 2 develops the thermo-acoustic forward model with an explicit thermal-expansion correction, states the uniqueness theorem for the resulting Volterra integral map, and describes the conjugate-gradient inversion regularized by the Morozov discrepancy principle. Section 3 verifies the regularized inversion on five canonical heat flux profiles (constant, sinusoidal, triangular, step, and multi-step). Section 4 reports a flat plate heating experiment on 20# steel in which the reconstructed heat flux is compared against four independent thermocouples at the temperature-field level, together with the associated uncertainty budget. Section 5 discusses the practical scope and limitations of the method, and Section 6 concludes with a three-tier summary of the analytical, numerical, and experimental evidence.

2. Materials and Methods

The logical chain of this work runs in four links: heat flux produces a temperature field (forward problem); the temperature field maps to an observable propagation time (TOF measurement model); a single TOF sequence suffices to determine heat flux (uniqueness theorem); and an inversion algorithm turns the theory into a computable method.

2.1. Thermo-Acoustic Coupling Forward Problem Model

Consider a solid structure of thickness L0, with one surface (denoted x = 0, heated surface) exposed to unknown transient heat flux q(t), and the other surface (x = L0, back wall) insulated. An ultrasonic transceiver on the cold side sends waves along the thickness direction; they reflect from the back wall as a pulse-echo, traversing a double-pass acoustic path of 2L0. Measuring the echo propagation time (time of flight, TOF) as a function of time, we seek the heated surface heat flux q(t) and internal temperature field T(x,t). The measurement principle is shown in Figure 1.
Figure 1. Schematic diagram of the ultrasonic heat and temperature measurement principle.
Assuming constant material properties, the temperature field satisfies the one-dimensional transient heat conduction equation [22]:
ρ c ∂ T ∂ t = k ∂ 2 T ∂ x 2 ,   0 < x < L 0 ,   0 < t ≤ τ
− k ∂ T ∂ x | x = 0 = q ( t ) ,   ∂ T ∂ x | x = L 0 = 0
T x , 0 = T 0  
where ρ is density (kg/m3), c is specific heat capacity (J/(kg·K)), k is thermal conductivity (W/(m·K)), τ is measurement duration (s), q(t) is time-varying heat flux (W/m2), and T0 is initial uniform temperature (K).
Two assumptions underpin Equations (1)–(3). The 1D form requires either uniform surface heat flux or a specimen lateral dimension much larger than the thickness, plus negligible lateral heat loss after insulation wrapping. The constant-property assumption holds in the medium-low temperature range. For 20# steel in the 20~150 °C range, thermal conductivity k varies by about 5%, specific heat c by about 5%, and density by less than 0.5%, giving a thermal-diffusivity drift of about 10%. The quantitative impact of these variations on the reconstruction is assessed in Supplementary Materials S4 and is dominated by the acoustic-calibration terms rather than by the thermal-property spread. Beyond this temperature range or for phase-change materials, variable-property models k(T), c(T) need to be introduced and recalibrated, which is future work.
Equations (1)–(3) constitute the forward problem: given heat flux history q(t), the temperature field T(x,t) is uniquely determined.

2.2. Time-of-Flight (TOF) Measurement Model

The speed of sound in the material varies with temperature. Over a limited range, it can be expressed as V(T) = aT + b, where a and b are constants obtained from calibration experiments. The temperature dependence of the shear-wave speed, V(T) = aT + b with a = −0.3988 m/(s·°C) and b = 3251.5 m/s, was established by pulse-echo calibration on 20# steel. Its range of validity is room temperature to 100 °C, which covers the maximum temperature encountered in this study; over this range it reproduces the calibration data with an RMS deviation of 3.2 m/s (0.10% of V). The associated uncertainties, u(a) = 0.043 m/(s·°C) and u(b) = 2.6 m/s (95%), are propagated in the uncertainty analysis. The calibration data, alternative fits and residuals are provided in Supplementary Figure S13.
If one ignores thermal expansion, the ultrasonic echo propagation time TOF is simply [18]:
t tof ( t ) = 2 ∫ 0 L 0 1 V ( T ( x , t ) ) d x
But estimating with L0 = 10 mm and an average temperature rise of about 100 °C for typical 20# steel, the TOF change due to expansion is about 8 ns, approximately 4 times the ultrasonic acquisition system time jitter specification (±2 ns). Treating L as a constant would let this systematic shift leak into the inversion as a spurious temperature/heat flux signal, with bias accumulating over time.
Therefore, we reformulate in material coordinates. Using the undeformed configuration x as the integration variable, the heated micro-element length becomes 1 + α L Δ T d x (one-dimensional free expansion approximation, where α L is the linear expansion coefficient), and the measurement equation reads:
t tof ( t ) = 2 ∫ 0 L 0 1 + α L [ T ( x , t ) − T 0 ] V ( T ( x , t ) ) d x
Equation (5) drops higher-order expansion terms and waveguide geometric effects (the 1D longitudinal path is assumed to be unchanged).

2.3. Uniqueness of Inverse Problem Based on Single TOF

Before constructing the inversion algorithm, we must confront a foundational question: can a single propagation time measurement curve ttof(t) uniquely determine the surface heat flux q(t) and internal temperature field T(x,t) within the one-dimensional constant-property class specified by (A1)–(A4) below? If there exist two different heat flux histories that produce identical propagation time signals, then no inversion algorithm can distinguish them, and the single-measurement method of this paper loses its theoretical foundation.
Physically, first, a single TOF measurement at time t encodes the path-integrated temperature along the entire thickness. Heat enters only from x = 0, so the temperature field at any instant carries an irreversible record of everything that has flowed in. Heuristically, each new TOF datum adds one further independent constraint on the unknown heat flux history; the rigorous statement is the injectivity of the continuous forward operator, established in Theorem 1 and clarified in Remark 1 below.
Second, and more subtly, heat that has just entered the structure at time t concentrates in a thin thermal layer near the heated surface (penetration depth proportional to α ∆ t ). This freshly injected heat produces an immediate, positive contribution to the rate of change in TOF at that instant. Mathematically, when the measurement equation is differentiated with respect to time and integration by parts is applied, the current heat flux difference Q(t) = q1(t) − q2(t) “emerges” at the boundary multiplied by a coefficient k·w(0) that is strictly positive and never degenerates. We can call this the “instantaneous visibility” property: the current unknown always appears with a non-vanishing coefficient, much like a non-zero diagonal entry in a lower-triangular system.
Third, because the heat conduction equation is causal (the solution at time t depends only on heat input at earlier times), the heat flux difference Q can be expressed through a Volterra integral equation of the second kind. The memory kernel of this equation is bounded by elementary properties of the heat kernel (energy conservation, non-negativity, and mild singularity of the surface trace). A standard time-marching argument then shows that Q must vanish identically: starting from t = 0 where Q = 0 (zero initial condition), one advances segment by segment, and at each step the “instantaneous visibility” term dominates the bounded memory of past history, forcing Q ≡ 0. Once Q ≡ 0, the temperature difference θ also vanishes by energy estimation, completing the proof that q1 = q2 and T1 = T2.
In summary, the uniqueness rests on a competition between causality and diffusion. Heat enters from one side, only forward in time; freshly injected heat is immediately visible at the boundary. As long as the measurement has positive sensitivity to local temperature near the heated surface—guaranteed by C α > 0 and the boundedness of w on the calibration interval—no two heat flux histories can masquerade as the same TOF sequence. This is an injectivity statement; it does not by itself imply stable reconstruction under noise (see Remark 1).
The rigorous proof follows.
Assumptions:
(A1) ρ , c, k, α L are positive constants;
(A2) V(T) = aT + b, a < 0, b > 0, and both solutions take values in a closed interval [0,τ], on which 0   <   v m i n ≤ V T ≤ v m a x   < ∞ (the calibration range);
(A3) q1(t) and q2(t) are piecewise continuous on [0,τ];
(A4) Both solutions T1 and T2 satisfy Equations (1)–(3) and give the same measured propagation time:
t tof , 1 ( t ) = t tof , 2 ( t ) = t tof , m ( t ) ,   ∀ t ∈ [ 0 , τ ]
(A5) The specimen thickness L 0 is known a priori, together with ρ , c, k, α L , and the acoustic-velocity calibration V(T) = aT + b.
Theorem 1.
Under assumptions (A1)–(A4), q1(t) = q2(t) on [0,τ], and T1(x,t) = T2(x,t) on [0,L0] × [0,τ]. That is, the surface heat flux and internal temperature field are uniquely determined by a single propagation time measurement curve.
Remark 1
(what is and is not claimed). Theorem 1 is an injectivity result for the continuous forward operator F: q to ttof, defined by (1)–(3) and (5). It does not assert that the discrete reconstruction from finitely many noisy samples is accurate, that is numerical observability, examined in Section 3.3 and Section 3.4, nor that F−1 is continuous, i.e., stability. The latter does not hold: the problem is ill-posed, which is precisely why the inversion of Section 2.4 is regularized by the Morozov discrepancy principle. Uniqueness guarantees that a well-regularized algorithm has a single correct target; it does not by itself bound the reconstruction error under noise.
Proof of Theorem 1.
Note that Δ T = T 1 − T 2 and Q   =   q 1   −   q 2 .
  • Step 1: Transform the measurement constraint into a weighted-integral identity
Define f T = 1   +   α L T   −   T 0 / V T , the integrand of the measurement model (5). Subtracting the two instances of Equation (5) under (A4), bringing f T 1   −   f T 2 to a common denominator and expanding, the quadratic terms α L   a   T 1 T 2 and the constant terms α L   b T 0 cancel identically, leaving the exact algebraic identity:
f ( T 1 ) − f ( T 2 ) = C α ( T 1 − T 2 ) V ( T 1 ) V ( T 2 ) ,   C α = α L V ( T 0 ) − a = α L b + ( α L T 0 − 1 ) a
with no remainder and no linearization in α L . By (A1)–(A2), C α   =   α L   V T 0   +   − a is the sum of two positive quantities, hence C α   >   0 . For 20# steel with a = −0.3988 m·s−1·°C−1, b = 3251.5 m·s−1, T0 = 26 °C, and α L = 12 × 10−6 K−1, one finds V(T0) ≈ 3241.1 m·s−1, C α ≈ 0.4377 m·s−1·K−1, and κ α   : =   C α / − a ≈ 1.0975 ≈ 1.10. Hence, for any t ∈ [0, τ],
∫ 0 L 0 w ( x , t ) Δ T ( x , t ) d x = 0
where the weight w ( x , t ) :
w ( x , t ) = C α V ( T 1 ( x , t ) ) V ( T 2 ( x , t ) )
From (A2) and C α > 0 , w is bounded between two positive constants C α / v m a x 2 and C α / v min 2 . Moreover, w   =   κ α ⋅ w 0 with   w 0 =   − a / V T 1 V T 2 the expansion-free weight used in the submitted version; the expansion therefore rescales the weight by the fixed positive factor κ α ≈ 1.10 without altering the structure of the proof, and setting   α L = 0 recovers w0.
  • Step 2: Instantaneous visibility of boundary heat flux
The control equations and initial conditions for both solutions q 1 , T 1 and q 2 , T 2 are the same; subtracting gives the definite solution problem satisfied by Δ T .
ρ c ∂ Δ T ∂ t = k ∂ 2 Δ T ∂ x 2 − k ∂ Δ T ∂ x | x = 0 = Q ( t ) ,   ∂ Δ T ∂ x | x = L 0 = 0 Δ T ( x , 0 ) = 0
where Q t = q 1 ( t ) − q 2 ( t ) .
Differentiating both sides of Equation (7) with respect to t, replacing ∂ ∆ T / ∂ t with the heat conduction equation, and integrating by parts twice using boundary conditions, the heat flux difference Q t “emerges” at the boundary with an explicit positive coefficient:
κ ( t ) Q ( t ) + ∫ 0 L 0 φ ( x , t ) Δ T ( x , t ) d x +   Ψ ( t ) = 0
In the formula:
κ ( t ) : = w ( 0 , t ) ρ c ≥ w min ρ c = : κ 0 > 0
φ ( x , t ) : = w t ( x , t ) + α w x x ( t )
Ψ ( t ) : = α w x ( 0 , t ) Δ T ( 0 , t ) − α w x ( L 0 , t ) Δ T ( L 0 , t )
Equation (10) is the precise mathematical expression of “instantaneous visibility”. The first term on the left is “heat flux difference entering at this moment × positive coefficient”, the coefficient k0 never degenerates; the remaining terms depend only on the existing temperature distribution and its boundary values—all products of past heat flux. Engineering-wise, it can be understood as the current row of a lower triangular linear system: the current unknown Q appears with a non-zero coefficient, while the contributions of “previous rows” (historical heat flux) are already determined, so it can be solved forward, segment by segment, along time.
  • Step 3: Causality and Volterra Equation
Since properties are constant, problem (8) is linear in Q, and its solution can be written as the superposition of responses to heat flux injected at past times (Duhamel principle):
Δ T ( x , t ) = ∫ 0 t Q ( s ) g ( x , t − s ) d s
where g(x,u) is the temperature response caused by applying a unit heat flux pulse at x = 0 (zero initial conditions, insulated back wall).
Substituting Equation (11) into Equation (10), we obtain a Volterra integral equation of the second kind [23] for the heat flux difference:
κ ( t ) Q ( t ) + ∫ 0 t K ( t , s ) Q ( s ) d s = 0
where the upper integration limit is t, which is precisely the mathematical form of causality—the equation at time t involves only unknowns before t.
  • Step 4: Boundedness of the memory kernel
Estimating K requires only three elementary properties of g, all corresponding to basic physical facts: energy conservation—all heat injected by a unit pulse remains in the plate; non-negativity—g ≥ 0 (maximum principle); heated surface pulse response g ( 0 , u ) ≤ C 0 u − 1 / 2 (well-known behavior of half-space kernel, integrable weak singularity); back wall response g(L,u) bounded. Thereby:
| K ( t , s ) | ≤   Λ 0 +   Λ 1 ( t − s ) − 1 / 2 ,   0 ≤ s < t ≤ τ
where Λ 0 and Λ 1 are constants depending only on ρ , c, k, α L , the velocity bounds v m i n , v m a x , and the data through the regularity estimates. Note that the explicit expression of g is completely unnecessary here—conservation, non-negativity, and mild divergence of the trace are sufficient.
  • Step 5: Time marching (causal bootstrapping)
Let M ( t ) : = max 0 ≤ s ≤ t | Q ( s ) | . From Equations (12) and (13):
M ( t ) ≤ Λ 0 t + 2 Λ 1 t κ 0 M ( t )
Taking δ > 0 such that Λ 0 δ + 2 Λ 1 δ ≤ κ 0 / 2 , then for all t ∈ [ 0 , δ ] : M ( t ) ≤ M ( t ) / 2 , Q ≡ 0 on [ 0 , δ ] . Then, translating the starting point, on [ δ , 2 δ ] the equation reduces to the same form; repeating the estimate gives Q ≡ 0 on [ δ , 2 δ ] . After τ / δ steps covering the entire [ 0 , τ ] , we obtain:
Q ( t ) ≡ 0 ,   ∀ t ∈ [ 0 , τ ]
Physically, δ is the time scale at which “instantaneous visibility beats historical memory.” Each step is forward substitution in a lower-triangular system—no room for ambiguity.
From Q ≡ 0 , Δ T satisfies the homogeneous problem (8) (zero heat flux, zero initial value, insulated back wall), and energy estimation gives Δ T ≡ 0 , i.e., T1  ≡ T2. The expansion correction enters the proof at exactly one place, the weight (9): it multiplies the expansion-free weight by the constant κ α > 0 and thereby rescales κ0, min, Λ0, Λ1, and the marching step δ. The structure is a positive, non-degenerate diagonal coefficient, a causal Volterra memory, a bounded kernel, and forward marching is unchanged. Theorem 1 is therefore a uniqueness result for the measurement model (5) as implemented in Section 2.4, Section 3 and Section 4. Theorem 1 is proved. Q.E.D. □

2.4. Ultrasonic Thermometry Algorithm Based on Conjugate Gradient

Theorem 1 guarantees that a single TOF sequence carries enough information to pin down a unique q(t). Turning this guarantee into a practical reconstruction is nonetheless non-trivial. The inversion is a nonlinear ill-posed problem [16,24]: limited data, noise sensitivity, and the ever-present risk of local optima. We adopt an iterative optimization strategy based on the conjugate gradient method (CGM) [24,25], alternating between “solve the forward problem” and “minimize the objective functional.”
The goal is to find q(t) that minimizes the mismatch between predicted and measured propagation times. Let t c ( t i , q ) be the TOF computed from the forward problem (1)–(3) driven by the candidate q(t) and Equation (5), and t m ( t i ) ( i = 1 , … , n m ) be the measured TOF at n_m time instances. The objective functional is [24]:
J [ q ] = ∑ i = 1 n m [ t c ( t i ; q ) − t m ( t i ) ] 2
By introducing the adjoint variable λ ( x , t ) , the gradient of J with respect to q can be derived by solving only one backward parabolic problem on the inversion state T:
− ρ c ∂ λ ∂ t = k ∂ 2 λ ∂ x 2 + S ( x , t ) ,   0 < x < L 0 ,   0 < t < τ ;   λ ( x , τ ) = 0  
where S ( x j , t i ) = 4 Φ ( T ( x j , t i ) ) [ t m ( t i ) − t c ( t i ) ]   , Φ ( T ) is the “change in one-way unit-length propagation time per unit temperature rise”, which reduces to 2/V(T) when α L = 0 (no expansion model).
Adjoint boundary conditions:
∂ λ ∂ x | x = 0 = 0 ;   ∂ λ ∂ x | x = L 0 = 0 ,   λ ( L 0 , t ) = 0  
The gradient is given by the trace of the adjoint variable at the heated surface:
g ( t ) : = ∂ J ∂ q ( t ) = − λ ( 0 , t )  
Given the initial value q0, the iteration format is:
q l + 1 = q l − β l P l
where the search direction is constructed according to the Polak–Ribiere formula:
P 0 = g 0 ,   P l = g l + γ l P l − 1 ,   γ l = ( g l ,   g l − g l − 1 ) ( g l − 1 ,   g l − 1 )
(·,·) is the integral inner product on [0,τ] (discrete implementation uses trapezoidal integration). The step size β l is determined by a linearized one-dimensional search along the search direction: U(x,t) is the sensitivity temperature field driven by boundary heat flux P l ( t ) (satisfying the same homogeneous initial value problem as Equations (1)–(3), − k U x | x = 0 = P l ( t ) corresponding to the homogeneous boundary of Equation (18)), and the linearized change in propagation time is:
δ t c ( t i ) = 2 ∫ 0 L 0 Φ ( T ( x , t i ) ) U ( x , t i ) d x
β l = ∑ i [ t c ( t i ) − t m ( t i ) ] δ t c ( t i ) ∑ i δ t c ( t i ) 2
For the first iteration with no historical direction information, take a unit step size β 0 = 1 .
Due to the ill-posedness of the inverse problem (unrestricted reduction in J on noisy data will invert noise into spurious heat flux structures), the Morozov discrepancy principle is adopted, stopping when the residual drops to the measurement noise level:
J [ q l ] ≤ η n m σ tof 2 ,   η = 1  
where σ tof is the standard deviation of propagation time measurements (this paper takes the instrument time jitter specification); for noise-free numerical examples, a machine-precision floor is substituted. Implementation also sets dual safeguards of maximum iteration count (1000) and “stop if no improvement for 20 consecutive steps” to prevent iteration stagnation in individual combinations.
As shown in Figure 2, the specific execution steps of the algorithm are as follows:
Figure 2. Calculation process of the thermal boundary inversion algorithm.
(1) Initialization: Input material thermal properties and dimensions, estimate the parameter q(t) to be identified, and initial temperature field;
(2) Forward problem solving: Solve the heat conduction equation, calculate the current TOF;
(3) Convergence judgment: If Equation (24) is satisfied, or the maximum iteration count (1000) and “no improvement for 20 consecutive steps” safeguard is triggered, output the result and terminate; otherwise, continue;
(4) Adjoint solving: Solve the adjoint equation and calculate the gradient;
(5) Update search: Calculate the conjugate coefficient, search direction, and step size;
(6) Parameter update: Update the heat flux, and return to step 2.

3. Numerical Verification and Result Analysis

3.1. Case Design

To verify the effectiveness and robustness of the inversion algorithm, we designed systematic numerical simulation experiments. First, “true, clean” TOF data (noise-free) test the inversion accuracy under ideal conditions. Then Gaussian white noise is added to simulate real measurement, and the focus shifts to a head-to-head noise-resistance comparison between our method and the traditional dual-measurement approach.
Two methods are defined. M1 (TOF-only) uses only the TOF channel with an insulated back wall (right side of Equation (2)). M2 (TOF + Tboundary) additionally measures back-wall temperature, replacing the insulated condition with a Dirichlet condition T R t   =   T L 0 , t , which references the classical ultrasound thermometry literature. The objective functional remains Equation (24) in both cases; TR enters the forward, adjoint, and sensitivity problems as a hard back-wall boundary constraint. M2 thus corresponds to the standard “TOF + Tboundary” dual-sensor method from the literature. Both methods share the same algorithm framework and stopping criterion—this is essential for a fair comparison. Unless stated otherwise, the inversion starts from the true-value mean, with discrepancy-principle stopping, a 1000-iteration cap, and stagnation protection (stop if no improvement for 20 steps).
It is important to clarify the rationale for this M2 implementation. The hard-Dirichlet treatment of boundary temperature is not an arbitrary design choice but corresponds to the standard implementation in the existing ultrasonic thermometry literature: both Wei et al. [19] and Shi et al. [21] impose measured boundary temperatures as Dirichlet conditions in their inversion algorithms. The present comparison therefore evaluates M1 against the best-published dual-measurement implementation, not against a hypothetical optimal joint inversion that treats boundary temperature as soft data. A regularized joint inversion (TOF + Tboundary as dual soft constraints with adaptive weighting) could in principle mitigate the noise vulnerability identified below, but its design requires additional hyperparameter tuning and is beyond the scope of this work.
Material and geometry: specimen material is 20# steel, with constant properties within the model applicability domain (≤150 °C) (Table 1). Numerical thickness takes L = 10 mm as the main case. Sampling frequency is 1 Hz, total measurement duration is 200 s, i.e., 200 measurement points are collected.
Table 1. Material properties and measurement parameters (20# steel).
Heat flux cases: five heat flux forms (cases A–E, Table 2 and Figure 3) cover constant, periodic oscillation, sharp pulse, step, and multi-step profiles—the typical shapes encountered in practice.
Table 2. Heat flux case list.
Figure 3. True heat flux histories for five test cases.
Error metrics: Heat flux inversion error uniformly uses normalized error (NRMSE):
NRMSE q = ∫ 0 τ ( q inv ( t ) − q true ( t ) ) 2 d t ∫ 0 τ q true 2 ( t ) d t
When qtrue = 0, relative error is undefined; use the maximum absolute error (W/m2) for that period, which is explicitly declared. Temperature field error is evaluated at 6 probe positions and in the time domain using RMS error and maximum absolute error (°C).

3.2. Benchmark Accuracy

This section mainly discusses the inversion accuracy of the two algorithms under clean data. Table 3 gives the inversion accuracy of five cases and two configurations under noise-free conditions. All cases have NRMSE not exceeding 0.632%. The triangular pulse (case C) is easiest (M1: 0.176%); the step (case D) is hardest (M1: 0.632%), which makes sense: two sudden flux jumps are the most demanding test for any full-time-domain tracker. M2 is comparable to or marginally better than M1 (case C: 0.153% vs. 0.176%) and converges roughly an order of magnitude faster (10~62 vs. 166~406 iterations). The back-wall temperature hard constraint, when noise-free, genuinely reduces ill-posedness.
Table 3. Clean benchmark inversion accuracy (noise-free, n = 30).
Because the synthetic TOF records are generated with the same forward operator that the inversion subsequently uses, the sub-0.65% errors reported in Table 3 primarily attest to the consistency of the numerical implementation—discretization, adjoint gradient, and Morozov stopping rule.
Figure 4 compares the reconstructed heat flux histories with the prescribed q(t) for the five canonical cases under noise-free conditions. Three features are worth noting. First, the ordering of the residual errors is not monotonic in the temporal frequency content of q(t): case C (triangular, NRMSE 0.176%) < case A (constant, 0.246%) < case E (multi-step, 0.259%) < case B (sinusoidal, 0.456%) < case D (step, 0.632%). Case C, despite the fastest nominal ramp, is the best-reconstructed because its profile is continuous and its derivative discontinuity occurs only at the two apex points, whereas case D has a single jump whose location is exactly recovered but whose amplitude is smeared over a few CGM iterations. Second, the residual errors concentrate in narrow time windows around the derivative discontinuities rather than being distributed uniformly across the record; away from these features the reconstruction is essentially exact (relative error < 10−4). Third, the sub-0.65% overall error level primarily reflects the consistency of the numerical implementation rather than an independent validation of the method, because the synthetic TOF records are generated by the same forward operator that the inversion uses.
Figure 4. Clean benchmark reconstruction comparison.
Temperature field reconstruction quality (M1, M2) is shown in Table 4: under clean data, full temperature field RMS error is about 0.002 °C; both single-TOF measurement and “TOF + temperature” measurement can achieve sub-degree temperature field reconstruction accuracy under noise-free conditions.
Table 4. Temperature field reconstruction quality (M1, M2, n = 30).
The expansion correction of Equation (5) is not a cosmetic refinement. When the forward and inverse models disagree on the expansion term (forward with expansion, inverse without), the reconstruction carries a systematic error floor of up to ≈9.5 pp NRMSE under noise-free conditions and ≈2.3~4.4 pp under σ t o f = 2 ns at L = 34.6 mm; the expansion-matched inversion removes it (Supplementary Table S1 and Figure S1). All results in this paper use the expansion-matched model.

3.3. Initial Value Independence

The uniqueness proof in Section 2.3 theoretically guarantees at most one solution. Its numerical evidence must be given by algorithm behavior: Starting from very different initial values, does the inversion converge to the same solution? This section discusses the initial value independence of the two methods.
In the discussion of initial value independence, case D step heat flux is selected. Under noise-free conditions, six initial values q 0 ≡ κ × q ¯ true are taken, κ ∈ { 0 , 0.5 , 0.7 , 1.0 , 1.3 , 1.5 } ( q ¯ true = 8100 W/m2, covering zero initial value to ±50% magnitude deviation). The converged solutions for each initial value are shown in Table 5. All six initial guesses yield converged solutions with NRMSE between 0.55% and 0.66% (M1) and 0.40% and 0.54% (M2), confirming that the inversion is insensitive to the initial value and consistent with the uniqueness theorem.
Table 5. Initial value independence (case D, noise-free, n = 1).

3.4. Noise Robustness

In the actual measurement process, the acquisition of TOF and boundary temperature TR is affected by software and hardware systems, the measurement environment, and other factors to a certain degree of noise. To simulate this, we superimpose white noise on the forward-problem TOF and TR, mimicking the random errors in ultrasonic measurement and temperature acquisition.
The TOF measurement method (M1) uses only the TOF channel, and its accuracy depends only on σtof. The NRMSE error results are shown in Table 6 and Figure 5. Taking the noise-free case as reference, 1 ns noise raises NRMSE to 9.8% (A)/24.2% (D)/12.4% (E); 2 ns (upper limit of instrument specification) gives 14.8%/31.9%/18.6%; 5 ns gives 23.2%/51.1%/30.0%. The degradation trend is consistent across all three cases. The largest increment occurs between the noise-free limit and σtof = 1 ns (+9.6, +23.6 and +12.1 pp for A, D and E), after which the curves grow sub-linearly (+5.0, +7.7 and +6.3 pp from 1 to 2 ns, and +2.8, +6.4 and +3.8 pp per ns from 2 to 5 ns). Once the Morozov threshold is raised to the noise level the iteration stops after only 8 to 10 steps, and this early stopping caps the rate at which additional jitter is converted into reconstruction error.
Table 6. NRMSE_q (%) of TOF measurement method (M1) vs. σtof (n = 30).
Figure 5. M1 NRMSE degradation curve vs. σtof.
The “TOF + temperature” measurement method (M2) needs to process noise from both TOF and temperature channels simultaneously. The error results of NRMSE are shown in Table 7 and Figure 6. Taking case A, σtof = 0 as example: as σT increases from 0 to 0.5, 1.5, 2.5 °C, NRMSE jumps from 0.222% to 39.9%, 119.3%, 199.1%. Case D at σT = 2.5 °C, σtof = 1 ns reaches 155.6%. This trend is without exception across all three cases.
Table 7. NRMSEq (%) noise matrix of “TOF + temperature” measurement method (M2) (n = 30).
Figure 6. M2 noise matrix heatmap.
The comparison of the two methods at the noise point σtof = 1 ns, σT = 2.5 °C is shown in Table 8 and Figure 7: M1 is 9.8%/24.2%/12.4% (A/D/E), M2 is 97.4%/155.6%/88.7%, with M1 markedly below the hard-Dirichlet dual-measurement scheme M2 at the same noise point.
Table 8. Method comparison at noise point (σtof = 1 ns, σT = 2.5 °C) (n = 30).
Figure 7. Case D full-time comparison at the nominal noise point.
The different responses of the two methods to measurement errors stem from the different ways errors enter the inverse problem. In both M1 and M2, the TOF channel appears only as an objective functional residual: a soft constraint, regulated by the discrepancy principle. Stop when the residual hits the noise floor, and noise is not overfitted (Table 8: M1 needs just 8–10 iterations at nominal noise). The back-wall temperature in M2, by contrast, is a Dirichlet boundary condition on the state equation—a *hard* constraint. A deviation δT poisons the entire computed temperature field and, through Equation (5), the predicted TOF. The system becomes internally inconsistent: the temperature constraint and the noisy TOF data pull in incompatible directions, and the inversion converges to a distorted compromise.
In addition, the information structure of the two measurements of heat flux history also differs. TOF, as an integral measurement along the entire thickness (Equation (5)), has a smooth integral response to heat flux history; back-wall temperature is sensitive only to recent heat flux, and recovering heat flux from it requires approximate differentiation of the data, naturally amplifying noise.
Synthesizing Table 6, Table 7 and Table 8, under clean data M2 is slightly better and faster than M1 (best case 0.153% vs. 0.176%), when the back-wall temperature constraint is beneficial prior information. But when σT ≥ 0.5 °C, M2 NRMSE is not less than 35.8% (Table 7 case E, σT = 0.5 °C), comprehensively inferior to M1 worst value 31.9% at σtof = 2 ns (case D). Therefore, under actual conditions where temperature measurement accuracy cannot be better than about 0.5 °C, single-TOF measurement (M1) is a more robust method. The advantage of M2 exists only in the ideal case where temperature measurement error is negligible.

4. Experimental Verification at the Temperature-Field Level

The experimental comparison reported below tests two things: (i) that the full inversion pipeline with TOF extraction, filtering, CGM iteration with the discrepancy stopping rule runs stably on physical data and produces a physically plausible heat flux history; (ii) that the temperature field obtained by propagating this heat flux history through the forward conduction model agrees with four K-type thermocouples OMEGA Engineering, Norwalk, CT, USA (Class II, ±2.5 °C) that were not used at any stage of the inversion. The comparison does not independently verify the magnitude or the temporal evolution of the recovered q(t), because no calibrated heat flux sensor or electrical-power balance was available in the present campaign. This limitation is discussed further in Section 4.3, maximum temperature (uncertainty budget) and Section 6 (future work).

4.1. Experimental System

A cylindrical specimen is heated on one side. Ultrasonic pulse-echo measures the TOF through the specimen, from which we invert the surface heat flux history. Embedded thermocouples record the internal temperature as independent verification. The system has three subsystems: ultrasonic measurement, heating, and temperature acquisition, as shown in Figure 8.
Figure 8. Schematic diagram of the experimental system.
The specimen is a circular cylinder of 20# steel, diameter 65 mm, thickness L0 = 34.6 mm, resting freely on top of a far-infrared ceramic heater plate (400 × 280 mm2, rated 3300 W). There is no clamping, no adhesive bonding, and no mechanical fastening anywhere on the specimen. The lateral surface and the back (cold) face are loosely wrapped with aluminum silicate cotton insulation (thermal conductivity 0.02 W/(m·K), thickness 10 mm) to suppress lateral heat dissipation and ensure one-dimensional heat conduction approximation. The EMAT probe (custom-built at the State Key Laboratory of Aerodynamics, Mianyang, China) is a custom permanent-magnet + coil unit held against the cold back face by magnetic attraction alone; there is no couplant layer, no mechanical clamp, and no preload beyond the magnet’s own holding force (which is uniform, small, and always perpendicular to the back face).
The one-dimensional character of the configuration is supported quantitatively. The far-infrared heater (400 × 280 mm2) exceeds the heated face (Ø 65 mm; 3318 mm2) by a factor of ≈34, so the incident flux is spatially uniform to first order; all four thermocouples lie at the same radial offset (22.5 mm) within the projected heater area. Through the 10 mm aluminum silicate blanket ( λ i n s = 0.02 W/(m·K)) the effective conductance is h e f f = λ i n s / δ i n s = 2.0 W/(m2·K), which with k = 48 W/(m·K) gives B i a x i a l = h e f f   L 0 / k   =   1.4   ×   10 − 3 and B i r a d i a l   =   h e f f   d / 4 / k   =   6.8   ×   10 − 4 , both two orders of magnitude below 0.1: the back face is effectively adiabatic over the 300 s record and radial gradients remain below ≈1% of the axial gradient. With α = k / ρ c   =   1.27   ×   10 − 5 m2/s, the radial diffusion time d / 2 2 / α ≈ 83 s is short relative to the record, so any residual radial gradient is smoothed well before the peak-flux window (t ≈ 250 s), where the reconstruction is dominated by axial information. The worst-case lateral loss, λ i n s Δ T / δ i n s ≈ 1000 W/m2 at ΔT = 500 K, is ≈3% of the peak recovered flux (the ratio rises toward ≈27% in the low-flux tail, q ≈ 3.7 × 103 W/m2). Radial thermocouple profiling was not part of the present campaign; it is listed in Section 6 as a follow-up measurement that would confirm this bound directly.
The temperature dependence of the shear-wave speed, V(T) = aT + b with a = −0.3988 m/(s·°C) and b = 3251.5 m/s, was established by pulse-echo calibration on 20# steel (Section 4.1). Its range of validity is room temperature to 100 °C, which covers the maximum temperature encountered in this study (80.1 °C, Section 4.2); over this range it reproduces the calibration data with an RMS deviation of 3.2 m/s (0.10% of V). The associated uncertainties, u(a) = 0.043 m/(s·°C) and u(b) = 2.6 m/s (95%), are propagated in the uncertainty analysis of Section 4.3. The calibration data, alternative fits and residuals are provided in Figure S13.
The specific situation of experimental equipment is shown in Table 9.
Table 9. Experimental equipment and parameters.
It should be noted that the electrical parameters (voltage/current/power) of the flat plate heater cannot be recorded, so the input heat flux cannot be directly calibrated through electrical parameters. Therefore, we adopt an “indirect verification route” of “inverting heat flux, substituting it back into the forward problem to calculate the temperature field, and comparing the temperature field with thermocouples”.
The ultrasonic chain uses a custom electromagnetic acoustic transducer (EMAT, 5 MHz center frequency,custom-built at the State Key Laboratory of Aerodynamics, Mianyang, China) mounted on the cold surface via electromagnetic coupling, with stable contact throughout heating. Shear horizontal waves propagate along the thickness and reflect from the back wall. Echo signals are acquired at 1 Hz by a custom system (jitter specification ±2 ns). TOF at each step is extracted by peak picking from the A-scan; the absolute TOF is obtained by adding the initial propagation time measured at T0 = 28.3 °C.

4.2. Experimental Results and Error Analysis

Figure 9a shows the measured TOF sequence. The raw data (gray) are noisy; Savitzky–Golay filtering (31-point window, 3rd-order polynomial) produces the smooth curve (blue) used as inversion input. The Morozov discrepancy principle is applied with ε = σ ⋅ √ N , where σpost is the post-Savitzky–Golay-filter noise level estimated from Supplementary Materials S7, not the nominal instrument jitter σnom. This choice is essential: using σnom underestimates the effective residual after filtering and drives the CGM iteration to overfit the smoothed noise.
Figure 9. Experimental TOF and inverted heat flux.
The timing budget of the TOF chain combines quantization (0.29 ns), interpolation (0.17 ns), repeatability (2.0 ns) and residual-offset (1.15 ns) contributions to uc = 2.34 ns (U = 4.7 ns, k = 2). The Morozov threshold of the filtered inversion uses the post-filter noise level σpost rather than the raw jitter specification.
The 144 ns systematic offset between the measured initial TOF (21,500.96 ns) and the model prediction 2L0/V(T0) = 21,356.7 ns arises wholly in the cold measurement chain—the fixed electronic group delay of the EMAT system plus the skin-depth launch/detection path, with no couplant contribution. All of these elements, being thermally decoupled from the heated specimen, are temperature-independent to within a few nanoseconds over the 300 s record. This offset is subtracted before inversion.
The inverted surface heat flux q(t) is shown in Figure 9b: at the initial stage of heating, q is about 3.7 × 103 W/m2 (t = 50 s), then monotonically rises to about 3.2 × 104 W/m2 (t = 250 s), and slightly drops to 3.0 × 104 W/m2 at the end of the experiment. The entire heating process shows an approximately linear growth trend of heat flux, consistent with the physical process of the flat plate heater gradually heating up after power-on.
Feeding q(t) back into the forward problem gives T(x,t). Figure 10 compares the reconstructed temperature point-by-point against TC1–TC4. The agreement is encouraging. TC1, nearest the heated surface, deviates most (RMS 2.58 °C); the other three thermocouples stay within 1.1 °C RMS (Table 10).
Figure 10. Reconstructed temperature vs. thermocouple measurements.
Table 10. Statistical deviation between reconstructed temperature and thermocouples.

4.3. Comprehensive Uncertainty Analysis

Table 11 consolidates the reference measurement uncertainty. There are four independent contributions: K-type TC, acquisition-card accuracy, cold-junction compensation, and thermocouple-wire inhomogeneity.
Table 11. Contributions of the reference thermocouples.
Combined standard uncertainty:
u c   = ( 1.44 2 +   1.44 2 +   0.29 2 +   1.44 2 ) ≈ 2.50   ° C
Expanded uncertainty at k = 2 (≈95% confidence):
  U T T C   =   2 × u c ≈ 5.0   ° C
The RMS deviation between the reconstructed temperature and TC1 is 2.582 °C; against TC2~TC4 it is 1.0~1.1 °C in Table 12. Both values are strictly smaller than the expanded uncertainty U = 5.0 °C of the reference measurement.
Table 12. Comparison at each of the four depths.
The reconstruction is therefore statistically consistent with the thermocouple data at the 95% level; there is no evidence of a systematic bias beyond the sensor uncertainty.

5. Discussion

(1) Theorem 1 settles a question that has been open, at least implicitly, since the earliest ultrasonic thermometry work: does the path-integrated nature of TOF carry enough information to recover the full thermal state—without auxiliary boundary data? The answer is yes, and the reason is structural, not accidental. The causal structure of the heat equation, combined with the non-degeneracy of the heat kernel at the heated boundary, guarantees information sufficiency. The physical mechanism is worth emphasizing. Each new TOF sample provides a linearly independent constraint on the unknown heat flux history, because freshly injected heat concentrates near the surface and leaves an immediate, non-vanishing signature in the TOF rate of change. This “instantaneous visibility”—formalized through the Volterra integral equation of the second kind—is the mathematical engine of the uniqueness result. It is not a property of any particular algorithm; it is a property of the physics.
(2) The numerical experiments yield a result that runs counter to intuition: the simpler, single-channel method (M1) consistently beats the dual-channel method (M2) once temperature uncertainty exceeds ~0.5 °C (Table 6, Table 7 and Table 8). How can removing a measurement channel improve accuracy? The explanation lies in the asymmetry of how information enters the inversion. In both methods, TOF acts through the objective functional—a soft constraint whose noise impact is regulated by the Morozov discrepancy principle. The back-wall temperature in M2, however, enters as a Dirichlet boundary condition on the state equation: a hard constraint. A perturbation δT in boundary temperature does not merely add noise to the objective—it contaminates the entire computed temperature field and, through Equation (5), the predicted TOF. The result is an internally inconsistent system: the inversion is squeezed between incompatible constraints and converges to a distorted compromise.
(3) The experimental results show: The reconstructed temperature field agrees with the four thermocouple readings to within 2.6 °C RMS (TC1) and 1.0~1.1 °C RMS (TC2–TC4). Given the expanded uncertainty U ≈ 5.0 °C (k = 2) of the K-type Class II thermocouples, this level of agreement is a consistency check within the measurement error envelope rather than an independent validation of the recovered heat flux amplitude. Direct validation of q(t) requires an independent surface-flux reference, which is identified as the main direction for future work.
Limitations and Outlook: The uniqueness proof and measurement model assume constant thermal properties; extending to k(T), c(T) would widen the temperature range but requires reformulating the Volterra kernel analysis. The 1D model assumes uniform heating and negligible lateral loss; 2D or 3D extension demands multi-acoustic-path arrangements and new uniqueness analysis. The experiment covers a single geometry (34.6 mm flat plate) and moderate temperatures (≤150 °C); validation at higher temperatures, with different materials, and under aerospace-representative transient heating profiles remains to be done. Finally, the TOF extraction uses peak picking; cross-correlation or model-based deconvolution may push the fitting residual lower. These are the subjects of our ongoing work.

6. Conclusions

The evidence supporting the proposed method is naturally stratified into three tiers, each with its own scope and its own limitations. Tier 1 (mathematical): within the one-dimensional constant-property class of assumptions (A1)–(A4), Theorem 1 proves that a single noise-free TOF history uniquely determines the surface heat flux and the internal temperature field; this result is exact but conditional and does not imply stability (Remark 1). Tier 2 (numerical): model-consistent synthetic tests verify the implementation (clean-data NRMSE ≤ 0.65%). Tier 3 (experimental): the flat plate campaign provides an independent consistency check at the temperature-field level, not a heat flux validation. The main conclusions are as follows:
(1) Uniqueness of single TOF inversion. Using three properties of the heat kernel—energy conservation, non-negativity, and trace boundedness—we prove that a single TOF sequence uniquely determines surface heat flux and internal temperature field.
(2) Thermal-expansion-corrected model and algorithm. Linear expansion is absorbed into the TOF measurement equation via material-coordinate integration, preventing systematic time-shift bias. The CGM inversion algorithm with Morozov discrepancy stopping achieves NRMSE ≤ 0.65% across five heat flux cases with clean data.
(3) Single-TOF measurement is more robust than dual measurement under realistic noise. The crossover is sharp: M2 is marginally better under clean data (0.153% vs. 0.176%), but once temperature noise reaches 0.5 °C, M2 error exceeds 35.8%, while M1 holds at 6.97–31.9% under 1–2 ns jitter. At the nominal noise point (1 ns, 2.5 °C), M1 achieves 9.8–24.2% versus M2’s 88.7–155.6%. The mechanism: TOF noise is controlled by soft-constraint optimization and the discrepancy principle; temperature noise penetrates the state field through the Dirichlet hard constraint. This ordering is established against the hard-Dirichlet dual-channel scheme. A jointly regularized formulation remains future work.
(4) Experimental validation. The flat plate experiment provides an independent temperature-field consistency check (RMS deviation ≤ 2.58 °C, comparable to the Class-II thermocouple expanded uncertainty); it does not directly validate the recovered heat flux, for which a follow-up campaign with a calibrated flux sensor is planned.
Future work will introduce variable-property models k(T), c(T), extend the analysis to multi-dimensional geometries with multi-acoustic-path arrangements, and conduct experiments with instrumented heat flux references and radial thermocouple profiling to strengthen validation.

Supplementary Materials

The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/pr14233821/s1: Table S1. Reconstruction error with and without the thermal-expansion correction in the forward/inverse model. “Matched” = inversion with the expansion-corrected model, Equation (5); “mismatched” = expansion-free surrogate (alpha_L = 0). Noisy columns are means ± s.d. over n = 10 repetitions at sigma_tof = 2 ns. Table S2. NRMSE, peak-timing error and zero-flux MAE for Cases A and D at L = 10, 20 and 34.6 mm under sigma_tof = 0 and 2 ns (noisy: median [mean] over n = 10). Table S3. NRMSE versus initial-guess scaling kappa (q0 = kappa * q_ref) for Cases A–D at L = 34.6 mm, sigma_tof = 2 ns, means ± s.d. over n = 10. Table S4. NRMSE versus ±5 % perturbations of k, c, rho, alpha_L and of the sound-speed coefficients a, b, for Cases A/D/E at sigma_tof = 0 and 2 ns; dotted line = nominal baseline. Table S5. NRMSE of the single-TOF method (M1) and of the hard-Dirichlet dual-channel method (M2), which augments the TOF measurement with a back-surface temperature reading, at back-surface noise levels sigma_T = 0, 0.5 and 2.5 °C; means ± s.d., n = 10, sigma_tof = 2 ns. The M2-soft variant (penalised rather than imposed back-surface temperature) is not adopted; see Responses 13–14. Table S6. Delta-NRMSE (percentage points) for low/high perturbations of the nine input parameters, ranked by maximum |response|; Case D, noise-free baseline 0.65 %. Table S7. NRMSE for four processing pipelines (no filter; SG-31 with epsilon = sigma_nom; SG-31 with epsilon = sigma_post; SG-15 with epsilon = sigma_post), means over n = 10, sigma_tof = 2 ns. Table S7b. Recovered peak, end and minimum heat-flux ranges for the four processing pipelines, means over n = 10, sigma_tof = 2 ns. Table S8. NRMSE versus sampling rate f_s and record duration for Cases C34 and D34; blank cells = configurations not run. Table S9. NRMSE under white, AR(1), linear-drift and periodic TOF noise at equal sigma_tof = 2 ns equivalent, means ± s.d., n = 10. Table S10. Thermocouple geometry relative to the ultrasonic axis. Table S12. Combined standard and expanded uncertainties of the TOF channel, the temperature channel and the propagated reconstruction error (Group F root-sum-square). Table S13. Pulse-echo shear-wave calibration, 4 runs × 15 uniform-temperature states (59 states after gross-error rejection), 19.7–462.4 °C. Columns give the three candidate fits (full-range linear, Equation (3.1) as employed, quadratic) with residuals and 95 % confidence/prediction band half-widths; trailing band table lists equivalent TOF biases at L = 34.6 mm. Figure S1. Expansion-model sensitivity at L = 34.6 mm. Figure S2. Thickness scaling from numerical to experimental configuration. Figure S3. Initialization independence of the conjugate-gradient inversion. Figure S4. Property-mismatch (model-form uncertainty) study. Figure S5. Balanced dual-measurement comparison (M1 vs. M2-hard) at L = 34.6 mm. Figure S6. Global sensitivity (tornado) at the experimental thickness. Figure S7. Savitzky–Golay filtering window and stopping-discrepancy study. Figure S8. Sampling-frequency and measurement-duration operability map. Figure S9. Non-white noise models. Figure S11. Experimental reconstruction and temperature-field consistency check. Figure S13. Sound-speed calibration of 20# steel.

Author Contributions

Writing—original draft preparation and data curation, J.X.; validation, Y.C.; writing—review and editing, Y.-X.H.-F.; methodology, D.W.; Conceptualization, L.L. and Y.-X.D. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the State Key Laboratory of Aerodynamics Fund, grant number SKLA-JSSX-2024-JJXM-09.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

During the preparation of this manuscript, the authors used Qwen 3.7-Plus for the purposes of generating text and graphics. The authors have reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Hu, S.C.; Zhuang, Y.; Li, X.; Jiang, T. Hypersonic Aero-Heating Environment Research Model HyHERM-I: Experiment. Acta Aeronaut. Et. Astronaut. Sin. 2022, 43, 236–251. [Google Scholar] [CrossRef]
  2. Frankel, J.I.; Chen, H. Heat Flux Data Reduction Using a Preconditioning Trial Function. J. Thermophys. Heat Transf. 2020, 34, 109–120. [Google Scholar] [CrossRef] [Scilit]
  3. Zhang, Y.; Jiang, H.; Zhang, X. Review of the Research of Heat Flux Measurement Techniques for Hypersonic Aircraft. Electron. Meas. Technol. 2025, 48, 1–9. [Google Scholar] [CrossRef]
  4. Wang, G.; Liang, H.J.; Wei, Y.L.; Wang, X.H.; Zhao, J.; Li, X. Research Progress of Ultrasonic Temperature Measurement Technology in Ultra-high Temperature Extreme Environments. Metrol. Meas. Technol. 2024, 44, 1–13. [Google Scholar] [CrossRef]
  5. Zhu, G.S.; Nei, C.S.; Cao, Z.W.; Yuan, Y. Research Progress of Aerodynamic Thermal Environment Test and Measurement Technology. J. Exp. Fluid Mech. 2019, 33, 10. [Google Scholar] [CrossRef]
  6. Lynnworth, L.C.; Carnevale, E.H.; Mcdonough, M.S.; Fam, S.S. Ultrasonic Thermometry for Nuclear Reactors. Nucl. Sci. IEEE Trans. 1969, 16, 184–187. [Google Scholar] [CrossRef] [Scilit]
  7. Cheng, Y.; Zhao, S.; Shen, G.; Zhang, S.; Yao, P. Real-Time Temperature Monitoring of Lithium Batteries Based on Ultrasonic Technology. ACS Omega 2024, 9, 19517–19524. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Heenan, T.M.M.; Mombrini, I.; Llewellyn, A.; Checchia, S.; Tan, C.; Johnson, M.J.; Jnawali, A.; Garbarino, G.; Jervis, R.; Brett, D.J.L.; et al. Mapping Internal Temperatures during High-Rate Battery Applications. Nature 2023, 617, 507–512. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Wei, Y.; Liang, H.; Wang, G.; Xingqi, W.; Yang, L.; Zhou, H.; Yang, L.; Mu, X.; Yin, G. Ultrasonic Thermometric Measurement System for Solid Rocket Combustion Chambers. Ultrasonics 2021, 113, 106361. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Frankel, J.I.; Ekici, K. Revisiting Slug Calorimeters for Hypersonics. Aerosp. Sci. Technol. 2020, 102, 105869. [Google Scholar] [CrossRef] [Scilit]
  11. Yang, H. Real-Time Sensor for Measuring the Surface Temperature of Thermal Protection Structures Based on the Full-Time Domain Temperature Inversion Method. Sensors 2025, 25, 2227. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Wadley, H.N.G.; Norton, S.J.; Mauer, F.; Droney, B.; Ash, E.A.; Sayers, C.M. Ultrasonic Measurement of Internal Temperature Distribution and Discussion. Philos. Trans. R. Soc. A Math. Phys. Eng. Sci. 1986, 320, 341–361. [Google Scholar] [CrossRef] [Scilit]
  13. Wang, H.Z.; Yu, H.B.; Lin, F.L.; Xu, Z.Z. Method and Experiment of Noninvasive Temperature Estimation by Ultrasound Echo Pulses. In Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286); IEEE: New York, NY, USA, 1998. [Google Scholar]
  14. Chen, Y.; Qu, M.; Tang, Z.; Zhou, J.; Zheng, Y.; Zhang, G.; Xie, J. Noninvasive Measurement of Temperature for Tissue Based on Piezoelectric Micromachined Ultrasonic Transducers. Measurement 2026, 258, 119498. [Google Scholar] [CrossRef] [Scilit]
  15. Beck, J.V. Inverse Heat Conduction, Ill-Posed Problems; A Wiley-Interscience Publication; Wiley: Hoboken, NJ, USA, 1985. [Google Scholar]
  16. Ozisik, M.; Orlande, H.; Kassab, A. Inverse Heat Transfer: Fundamentals and Applications. Appl. Mech. Rev. 2002, 55, 5483–5489. [Google Scholar] [CrossRef] [Scilit]
  17. Ihara, I.; Takahashi, M. A New Method for Internal Temperature Profile Measurement by Ultrasound. In 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007; IEEE: New York, NY, USA, 2007; pp. 1–5. [Google Scholar]
  18. Ihara, I.; Takahashi, M. Ultrasound Thermometry for Monitoring Internal Temperature Gradient in Heated Material. In 2009 IEEE International Ultrasonics Symposium; IEEE: New York, NY, USA, 2009. [Google Scholar]
  19. Dong, W.; You, A.S.; Bi, N.S.; Ye, W.G.; Yan, X.D.; Guang, M.X. Reconstruction of Internal Temperature Distributions in Heat Materials by Ultrasonic Measurements. Appl. Therm. Eng. 2017, 112, 38–44. [Google Scholar] [CrossRef] [Scilit]
  20. Zhu, L.Y.; Deng, J.; Wei, D.; Gui, Y.W. Research on the Uniqueness and Algorithm of Multi-Parameter Identification in Coupling Thermal Acoustic and Solid Problem. Sci. Sin. Technol. 2023, 53, 330–340. [Google Scholar] [CrossRef] [Scilit]
  21. Shi, Y.A.; Wei, D.; Gui, Y.W.; Qian, W.Q.; Zeng, L.; Qiu, B. Research on Parameter Estimation in Ultrasonic Measurement of Internal Transient Temperature Distributions. Sci. China Technol. Sci. 2016, 46, 509–517. [Google Scholar] [CrossRef] [Scilit]
  22. Tao, W.-Q. Numerical Heat Transfer, 2nd ed.; Xi’an Jiaotong University Press: Xi’an, China, 2001. [Google Scholar]
  23. Polyanin, A.D. Handbook of Integral Equations; Chapman and Hall/CRC: New York, NY, USA, 2008. [Google Scholar]
  24. Orlande, H.R.B. Inverse Heat Transfer Problems. Heat Transf. Eng. 2011, 32, 715–717. [Google Scholar] [CrossRef] [Scilit]
  25. Atkinson, C. Methods for Solving Incorrectly Posed Problems. Bull. Lond. Math. Soc. 1985, 17, 621–622. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.