Abstract
Process modelling is an increasingly important tool in pharmaceutical manufacturing process design and operation. As a versatile unit operation, chromatography is well suited to exemplify general modeling methods across different unit operations and a broad variety of molecular classes. Accurate identification of phase-equilibrium in general, for any unit operation, and especially adsorption isotherm parameters, is essential for reliable mechanistic chromatography modeling, yet conventional inverse optimization approaches often struggle with nonlinear parameter spaces, local minima, and numerical instability. This work presents a homotopy-based optimization workflow that enables robust and reproducible estimation, exemplified by isotherm determination in ion-exchange (IEX) and reversed-phase (RP) chromatography. Experimental chromatograms of the main component are characterized using a new analytical linear amplitude (LA) peak model, which provides a consistent reference for constructing a continuous homotopy path between simulated and experimental peak shape parameters. Along this path, the isotherm parameters of steric mass action (SMA) and Langmuir models are iteratively optimized using a Levenberg–Marquardt scheme embedded in a differential-algebraic column model. To ensure numerical stability, the squared residuals are scaled by the Median Absolute Deviation (MAD), yielding a robust and scale-independent error measure. The approach is generally applicable for any adsorption isotherm system. The workflow reliably converges to a producible and physically meaningful parameter set, independent of the chosen initial values, and accurately reproduces chromatographic profiles across multiple gradients using a unified parameter set. In addition, selective weighting of LA shape parameters enables targeted refinement of critical peak features without compromising the fit quality of other gradients. The results demonstrate that homotopy-based optimization provides a stable and transferable foundation for mechanistic model calibration and supports predictive, model-based process development in preparative and manufacturing chromatography.
1. Introduction
In pharmaceutical, especially biologics manufacturing, model-based process design and optimization—from early stage development up to late stage manufacturing support as well as part of regulatory approval—are increasing in importance [1,2,3]. Efficient experimental parameter determination and model validation, including uncertainty quantification, are essential for acceptance in regulated environments. Chromatography is the key unit operation, offering various batch or continuous process options and diverse interaction mechanisms such as affinity, ion-exchange, hydrophobic interaction, mixed-mode, normal and reversed phase, as well as chiral separation [4]. The mechanistic diversity makes chromatography indispensable wherever the highest purity standards or the separation of structurally similar molecules are required [5,6,7,8].
Industrial relevance extends from the purification of biopharmaceutical active ingredients and drugs to peptide synthesis, food processing, and analytical quality control [9,10,11,12,13]. Applications span chiral and achiral synthetic molecules and biologics like monoclonal antibodies (mAbs), fragments, peptides, proteins, virus-like particles, exosomes, and cell therapy products [14,15,16]. Since chromatographic steps often account for a significant share of downstream processes costs [17], there is a strong interest in efficient, reproducible, and model-based strategies for process design.
Given the wide range of chromatographic modes used in preparative downstream processing, two systems are particularly relevant for this study: reversed-phase chromatography (RP) and ion-exchange chromatography (IEX). RP relies on hydrophobic interactions with a nonpolar stationary phase and is widely applied for high-resolution separations of peptides, small proteins, and synthetic molecules [13,18,19]. IEX is governed by reversible electrostatic interactions between charged analytes and oppositely charged functional groups on the stationary phase. Due to this charge-based selectivity, IEX represents one of the key technologies for the large-scale purification of recombinant proteins and mAbs [20,21]. At the preparative scale, however, peak shapes become significantly more complex than in analytical applications. High loadings and nonlinear adsorption effects generate plateau-like peaks that classical exponentially modified Gaussian (EMG) models can no longer describe adequately [22,23,24].
A variety of modeling approaches has been developed to support chromatographic process design, ranging from mechanistic simulation software to structure-based prediction tools and data-processing platforms. Mechanistic chromatography simulation and parameter estimation workflows are provided by commercial tools such as GoSilico™ (Cytiva) and academic frameworks such as CADET [25,26], while established peak shape and gradient analysis approaches (e.g., Chromulator, ChromDream) rely on classical Langmuir and SMA isotherms and retention prediction models [27,28]. Data-processing platforms like OpenChrom® enable chromatographic evaluation without mechanistic modeling [29], and consulting services from YMC and Ypso-Facto rely on proprietary in-house models [30,31]. Additional alternatives are being explored to improve performance, accelerate workflows, or increase freedom to operate for different business cases [32,33].
Despite these developments, in general the precise determination of the underlying adsorption equilibria for any molecule and any adsorption mechanism remains a major challenge. In RP systems, nonlinear retention mechanisms and strong dependence on gradient steepness complicate parameterization. In IEX systems, the SMA model—with its stoichiometric exchange coefficients, salt dependencies, and exponential terms—creates complex and often poorly conditioned parameter spaces; modified SMA isotherms extend this versatility further, covering a broad range of applications including modifier dependencies as well as pH [34]. These challenges are amplified at preparative scale, where nonlinear adsorption phenomena and the coexistence of different peak shapes must be considered. Classical approaches such as batch experiments, sequential gradient fitting, or local optimization can determine individual parameters, but require extensive experimental effort and are highly sensitive to initial values [23].
In this context, inverse parameter determination is gaining importance. It enables direct extraction of isotherm parameters from chromatographic gradient experiments, reduces the experimental effort, and allows simultaneous evaluation of multiple gradients [35,36,37]. This facilitates exploration of parameter ranges that are experimentally difficult to access. Practical implementation nonetheless remains challenging due to highly nonlinear isotherm models and complex preparative peak shapes, which together create rugged optimization landscapes.
To overcome these structural difficulties, homotopy-based optimization has emerged as a promising strategy, particularly in recent work by Cebulla et al. [38,39]. Homotopy addresses difficult optimization problems by gradually increasing model complexity along a continuous path, smoothing the parameter landscape and improving numerical stability. Previous applications, however, have been limited to analytical chromatography, where peak shapes can be described by EMG models. Application of homotopy to preparative chromatography with plateau-like peaks and highly nonlinear SMA isotherms has not yet been investigated.
This reveals a clearly defined gap in the literature: there is no robust, reproducible, homotopy-based workflow for determining isotherm parameters directly from preparative chromatographic gradients that covers both RP and IEX systems while accounting for the specific challenges of nonlinear isotherm models and preparative peak shapes. The goal of this work is therefore to develop such a workflow, introducing a new analytical peak shape formulation termed the “linear amplitude” (LA) model to capture plateau-like preparative peak shapes, and demonstrate its performance comprehensively. Specifically, the study aims to show that homotopy enables robust and reproducible convergence independent of initial conditions, even for highly nonlinear SMA isotherms and complex peak shapes. It further evaluates how homotopy-based optimization improves peak shape fidelity and enables reliable prediction of chromatographic separation performance. Overall, the study demonstrates that homotopy-based inverse parameter determination provides a powerful foundation for the model-based design of preparative chromatographic processes and contributes significantly to the reproducible identification of complex adsorption equilibria.
2. Materials and Methods
2.1. Workflow and Major Assumptions
The workflow, shown in Figure 1, is structured to ensure numerical stability and reproducible convergence for highly nonlinear preparative chromatographic systems. Peak fitting provides a consistent parameter basis, chromatographic simulation establishes the mechanistic link to the isotherm, and homotopy enables a smooth and controlled progression from simulated to experimental peak shapes. This sequential structure constructs a sequence of nonlinear fitting problems together with a sequence of excellent initial values for their numerical solution. This is of paramount importance, because the regions of fast local convergence of these methods can be very small due to the high nonlinearities immanent in chromatography problems. This approach ensures robust identification of Langmuir and SMA parameters across multiple preparative gradients.
Figure 1.
Schematic representation of the workflow for homotopy-based optimization.
The implementation follows this structure directly. A central Python 3.13.9 program orchestrates the modules for peak fitting, chromatographic simulation, homotopy construction, and parameter optimization. In the first step, the experimental chromatograms are imported and each component peak is fitted individually. The choice of the peak model depends on the characteristic peak shape. Plateau-type peaks with a distinct maximum on both sides are fitted using the LA model, whereas asymmetric peaks showing fronting or tailing are fitted using an EMG model. This ensures consistent representation of both major and minor components. The resulting peak shape parameters are stored and serve as the reference for all subsequent steps of the workflow.
In the second step, the chromatographic simulation is performed using an initial set of isotherm parameters. The simulated chromatograms are sampled at a temporal resolution that yields at least 500 data points within the evaluated time window, chosen such that all peaks, including narrow peaks and steep fronts, are resolved accurately, while the column is discretized into at least 100 axial elements. The simulated chromatograms are then evaluated using the same peak models (LA or EMG) as applied to the experimental data. To ensure mass conservation across all homotopy steps, the fitted peak areas of the simulated curves are constrained to match those of the experimental fits. The resulting peak shape parameters define the starting point of the homotopy path.
In the third step, the fitted parameters of the simulated chromatograms are compared with those obtained from the experimental data. A linear homotopy path is constructed between both parameter sets, gradually transitioning the peak shape parameters from the simulated profile (λ = 0) to the experimental profile (λ = 1). For each homotopy step, the corresponding target parameters are stored. This continuous path provides a structured reference for the subsequent optimization and enables controlled bridging of large differences between simulation and experiment.
In the final step, the isotherm parameters are optimized using a Levenberg–Marquardt algorithm. For each homotopy step, a chromatographic simulation is performed, the resulting peaks are fitted, and the obtained peak shape parameters are compared with the target parameters defined by the homotopy path. The optimization minimizes the sum of squared residuals between the simulated and target peak shape parameters across all investigated gradients. Each residual is normalized by the Median Absolute Deviation (MAD) of the corresponding peak shape parameter and multiplied by a weighting factor, which is set to unity unless specified otherwise. The MAD is calculated as the median of the absolute deviations from the median of the corresponding parameter values. This normalization accounts for differences in magnitude and variability between simulated and target parameters, preventing individual peak shape parameters from disproportionately influencing the optimization.
By minimizing these MAD-normalized, weighted squared residuals, the optimization proceeds along the homotopy path towards the experimental target parameters. Since the objective function is defined in peak shape parameter space rather than directly in concentration space, the goodness of fit of the final simulations is assessed independently by comparing the simulated and experimental chromatograms at their respective data points. Quantitative fitting errors are reported using the coefficient of determination (R2).
The chromatographic model itself was implemented using the CasADi framework with the IDAS solver for the differential-algebraic equations. To simplify the model while retaining the essential physical behavior, the following assumptions are applied:
- Radial gradients in the mobile phase are neglected.
- Isothermal operation is assumed for the entire chromatographic system.
- Column porosity and particle porosity are considered constant.
- Resin particles are assumed to have uniform size and shape.
- Axial dispersion and mass-transfer coefficients differ between components but remain constant with axial position.
- The inlet mobile-phase composition is fully defined and constant during injection.
- Liquid-phase incompressibility is assumed; flow rate is constant.
2.2. Governing Equations
Based on these assumptions, the column is represented as a one-dimensional axial lumped pore diffusion model, incorporating axial convection, axial dispersion, film mass transfer, intraparticle diffusion, and adsorption equilibria (Langmuir or SMA). For each component i, the bulk-phase concentration ci(z,t) evolves according to [23]
where εc is the column bed porosity, Dax,i the axial dispersion coefficient of component i, uint the interstitial velocity and dp the particle diameter. The parameter keff,i is the effective mass-transfer coefficient governing the exchange between the bulk-phase concentration and the pore-phase concentration . The axial dispersion coefficient is estimated using the correlation by Chung & Wen for packed beds [40], which reads
Here, Rep is the particle Reynolds number. The coefficients 0.2, 0.011 and 0.48 are empirical constants fitted to experimental dispersion data for packed beds: 0.2 represents the Reynolds-independent limit at low flow rates, whereas 0.011 and 0.48 are the pre-factor and the exponent of the flow-induced mixing term, which grows sub-linearly with Rep. The effective mass-transfer coefficient is computed using a resistance-in-series model that combines film diffusion and pore diffusion. The expression used in this work is
where kf,i is the film mass-transfer coefficient and Dpore,i the pore diffusion coefficient. This formulation follows the correlations described by Wilson and Geankoplis [41]. The pore diffusion coefficient is evaluated using the correlation of Carta and Rodrigues, which accounts for hindered diffusion inside the porous particle structure [42]. The pore-phase concentration is coupled to the adsorbed phase through a lumped pore-diffusion expression. In the present implementation, the pore-phase concentration is treated as an algebraic variable, while the adsorbed-phase qi(z,t) is dynamic for all binding components. The term
represents the rate of adsorption driven by the concentration difference between bulk and pore phases. For non-binding components, the adsorbed-phase rate is set to zero. Spatial derivatives are discretized using finite-difference schemes: an upwind scheme for the convective term (first derivative) at the inner nodes and a central scheme for the dispersive term (second derivative). For an axial grid with spacing h = L/N, the inner grid points (j = 1,…, N − 1) are approximated as
where L is the column length, N the number of axial grid elements, and h the axial step size. Boundary conditions are imposed via Danckwerts conditions: a Robin boundary condition at the inlet and a zero-gradient (Neumann) condition at the outlet [43]. To maintain second-order accuracy for the dispersion term at the inlet boundary, a fictitious point ci(z−1) is introduced via a central-difference approximation of the boundary flux
At time zero, the column is assumed to be completely unloaded with respect to the adsorbed protein components, i.e., qi(z,0) = 0. The modifier (salt in IEX, organic solvent in RP) is present at its non-zero starting concentration in both phases. To avoid exactly vanishing concentrations in the initial state, the bulk-phase concentrations ci(z,0) of all protein components are set to a negligibly small value of 10−12 at every axial position. The pore-phase concentrations are algebraic variables determined by the algebraic part of the DAE system; the same value is used as their initial guess.
The algebraic part of the DAE system is defined by the chosen adsorption isotherm. For IEX systems, the steric mass action isotherm relates the adsorbed concentration of each protein to the pore-phase concentrations of salt and proteins [6,34,44], in this case applied in a modified variant:
with
Here, is the modified equilibrium constant, Ks,i the salt-interaction parameter, Kp,i the protein-interaction parameter and Λ the ionic capacity of the resin. The coefficients vs and are the valence and pore-phase concentration of the salt, respectively. νi is the characteristic exchange number of replaced counter ions, and ai denotes the available-capacity term, with qmax,i as the maximum binding capacity. In the equation above, fSC,i is a competition parameter for side components describing steric hindrance by the main component. Salt and buffer are enforced as non-binding species through the algebraic relation .
For reversed-phase systems, a Langmuir-type isotherm with modifier-dependent parameters is used [6,45,46] via
In this case, KL,i represents the Langmuir equilibrium constant and cmod is the modifier concentration. The modifier dependence of the Langmuir parameters is described by power-law correlations (11)–(13)
where Hi is the Henry constant, and a1,i, a2,i, b1,i, b2,i are empirical correlation parameters. All equations used in the chromatography model are summarized in Figure 2 and categorized according to fluid dynamics (red), adsorption equilibrium (blue) and kinetics (green).
Figure 2.
Equations used for modeling the liquid chromatography process. Color coding indicates the model category: fluid dynamics (red), adsorption equilibrium (blue), and kinetics (green).
Peak-shape models are applied consistently to both simulated and experimental chromatograms. Plateau-type peaks of the main component are described using the linear amplitude model
where
and A1 and A2 represent the amplitude parameters of the plateau at the temporal anchor points x1 and x2. The terms σ1 and σ2 denote the characteristic widths between the retention time and the time where the flank reaches ~68% of the concentrations A1 and A2. Figure 3 illustrates the resulting fit function for the main component of the IEX-recombinant system, showing how the model reproduces the experimentally observed peak shape.
Figure 3.
Visualization of the linear-amplitude peak model showing the fitted left and right flanks defined by A1, A2, x1, x2, σ1, and σ2 for the main component of the IEX-recombinant system.
All other peaks are modeled using exponentially modified Gaussian functions [38,47,48]. The choice between tailing and fronting is determined by the sign preceding the second term inside the complementary error function
with
Here, μ is the peak position, σ the Gaussian width and τ the exponential decay parameter.
3. Results
3.1. IEX-Recombinant System with SMA Isotherm
A key result of the homotopy-based optimization strategy is its high robustness with respect to the chosen initial values of the isotherm parameters. Even when the initial parameters are deliberately varied widely—through random selection within the physically meaningful parameter space or through targeted shifts of individual SMA parameters—the optimization consistently converges to a nearly identical final set of parameters. To illustrate the chosen initial values, Table 1 shows the four different sets of initial parameters used for the optimization runs of the main component, covering both moderately and highly divergent initial conditions.
Table 1.
Normalized initial parameter sets for the main component in the four optimization runs.
Figure A1a in the appendix shows the evolution of the chromatograms for each run along the previously generated homotopy path. The robustness of the optimization is already evident in the final chromatographic profiles, shown in Figure A1b. For the main component of the recombinant IEX system, the simulated chromatograms show good agreement with the experimental data for all solvent gradients considered (20, 30, and 40 CV), achieving a coefficient of determination of approximately 92% across all four optimization runs. The remaining deviations can partly be attributed to experimental variability. Homotopy gradually guides the parameters into a consistent solution space, so that the gradients converge to a common compromise despite their different shapes and slopes. The 30 CV gradient is particularly well matched, as it is given increased weight in the objective function.
The stability of the optimization is also evident in the resulting SMA isotherms, shown in Figure A1c. For three representative salt levels—at the beginning of the peak, at the peak maximum, and at the end of the peak—nearly identical equilibrium curves are obtained for all optimization runs, regardless of the specific set of initial parameters. This is also reflected in the final isotherm parameters, which differ only marginally between the three independent optimization runs (runs 1–3). The close agreement between the independently estimated parameter sets supports the practical identifiability and reproducibility of the identified isotherm parameters.
Furthermore, the fourth optimization run used the final parameter set of the first run as its starting values, thereby testing whether re-optimizing from this point yields any further improvement. The chromatograms and isotherms remain almost unchanged, and the mean squared errors show no further reduction. This indicates that the optimum is reached after just one complete run through the homotopy workflow and that no further optimization steps are necessary. The same consistency is evident in the shape parameters shown in Figure 4 for all four optimization runs along the homotopy path. Notably, all parameters converge to nearly identical values toward the end of the path (λ = 1), regardless of the starting point. This convergence underscores the stability of the homotopy approach: even when initial conditions vary greatly, the path reliably guides the optimization to a common endpoint. Against this backdrop, the second run provides a particularly instructive example of this convergence behavior. At the beginning of the homotopy path, a distinct jump occurs in several shape parameters, indicating that the optimizer is passing through a region where the local structure of the fitting problem changes abruptly—a situation that in classical fitting methods would often lead to convergence to a locally inadequate solution or a suboptimal result. After this transition, the optimizer resumes a smooth, non-oscillatory trajectory along the homotopy path and converges toward a set of parameters that is both more physically plausible and, overall, more accurate. The fourth run continues this behavior. Although its starting point is identical to the endpoint of the first run, the optimizer continues the homotopy and further adjusts the parameters. However, the changes remain very small, indicating that the generated initial values lie close to the optima of the subproblems along the homotopy path. This reaffirms the robustness of the parameter set obtained, since no further significant improvements can be achieved and the path includes only minor fine-tuning adjustments.
Figure 4.
LA shape parameters for the main gradient (30 CV) of the IEX-recombinant system over the homotopy steps for all four optimization runs.
3.2. RP-Synthetic System with Langmuir Isotherm
For the RP-synthetic system, homotopy-based optimization likewise provides a stable and consistent path for determining the final set of isotherm parameters. The experimentally recorded chromatograms of the main component are reproduced very well for all three gradients. This is particularly evident for the main gradient (10 CV), whose peak shape is matched with exceptional precision due to a higher weighting in the objective functional. However, the left-hand amplitude of the main gradient cannot be adequately represented using the classical weighting settings. This is attributable to the differing tendencies of the three gradients, which force the optimizer to settle for a compromise solution. To specifically improve the peak shape of the main gradient, the shape parameter A1 was therefore given additional weighting, once with double and once with quadruple weighting (Figure 5). While the increased weighting leads to a significantly better fit of the main gradient, these modifications have virtually no negative effect on the remaining gradients (8 CV and 12 CV), since their influence on the objective function is smaller. With the additional weighting of A1, the coefficient of determination of the main gradient increases to approximately 97%, confirming the excellent agreement between the simulated and experimental chromatograms.
Figure 5.
(a): Chromatograms of the RP-synthetic system for three different weightings of the LA parameter A1. (b): Increasing the weighting of A1 raises the left-hand amplitude and improves the match to the experimental peak shape, particularly for the main gradient (10 CV).
The evolution of the shape parameters along the homotopy path also shows that the highest weighting of A1 stabilizes the optimization process. With this setting, both A1 and σ2 follow the homotopy path without abrupt jumps, whereas significant discontinuities occur with single and double weighting (Figure 6). The increased weighting raises the left-hand amplitude of the main gradient by roughly 25%, while the other relevant parameters such as x1, x2 and σ1 remain essentially unchanged. In contrast, A2 and σ2 vary considerably; however, due to the triangular peak shape of the RP system, different combinations of these parameters can reproduce the experimental peak equally well, as only one dominant amplitude governs the peak shape. In this case, the LA model is markedly better suited than the EMG model, since the steep front of the experimental peak cannot be captured adequately by the latter. The additional weighting damps the parameter updates and prevents the optimizer from being pulled into unfavorable regions of the parameter space. As a result, the optimization proceeds more steadily overall and leads to a more physically plausible and consistent final result.
Figure 6.
LA shape parameters for the main gradient (10 CV) of the RP-synthetic system over the homotopy steps for different weighting of A1.
As expected, the different weightings are also reflected in the trends of the remaining isothermal parameters, particularly in the Langmuir parameters (Figure 7a) as well as in the modifier-dependent parameters qmax, H, and K (Figure 7b). However, the changes remain moderate in magnitude and do not significantly affect the physical interpretation of the system. Overall, this demonstrates the potential of homotopy-based optimization to precisely reproduce different peak shapes through targeted weight adjustments without compromising the stability of the overall model.
Figure 7.
(a): Langmuir isotherms at three representative modifier concentrations for the final parameter set: blue corresponds to the start of the peak, green to the peak maximum, and red to the peak end. (b): Modifier dependence of the Langmuir parameters qmax, H, and K = H/qmax. In both subfigures, the different optimization runs with varying weightings of A1 are distinguished by their respective line styles.
4. Conclusions
This paper demonstrates that a homotopy-based optimization approach enables a reliable and numerically stable inverse determination of model parameters, as exemplified by isotherm parameters in mechanistic chromatography models. By continuously mapping between simulated and experimental peak shape parameters, a sequence of highly nonlinear fitting problems together with a sequence of excellent initial values for their numerical solutions can be generated. As a result, widely varying user-provided initial values yield the same physically plausible final solution (within numerical accuracy). This robust convergence confirms that homotopy is an effective strategy for stabilizing complex optimization problems.
The study builds upon established homotopy-based approaches, which have primarily been used in analytical chromatography systems to date [38], and extends their application to preparative systems with more complex peak shapes. The simultaneous treatment of multiple gradients demonstrates that the approach is capable of coherently mapping different chromatographic conditions and identifying a common set of parameters. This reinforces the method’s transferability and underscores its suitability for model-based process development.
A particular advantage of this workflow is the ability to specifically influence critical peak characteristics. The selective weighting of individual shape parameters allows for precise adjustment of the peak geometry without affecting the other gradients. This is particularly relevant for preparative applications in which asymmetric or plateau-like peak shapes occur and classical peak models reach their limits. The results show that weighting the LA parameter A1 for the RP-synthetic system significantly improves the peak shape of the main gradient, while the remaining parameters stay largely unchanged.
Furthermore, the use of MAD-scaled residuals in the Levenberg–Marquardt algorithm contributes markedly to numerical robustness. The median absolute deviation ensures that differences in the magnitude and variability of the peak shape parameters do not distort the error assessment. This is especially advantageous for preparative peak shapes, which often vary greatly and differ in scale.
Overall, this work demonstrates that the homotopy-based approach is a powerful and adaptable method for calibrating mechanistic models, as demonstrated for chromatography in different modes such as ion exchange and reversed phase chromatography with modifier and/or pH dependence. It stabilizes inverse parameter estimation, enables the precise reproduction of complex peak shapes, and meaningfully broadens existing homotopy-based strategies toward preparative and manufacturing chromatography. While the robustness of the workflow generally increases with the number of homotopy steps, approximately 100 steps were found to provide a favorable compromise between stability and computational efficiency. The overall optimization effort is primarily determined by the discretization level required for the investigated chromatograms as well as by the number of parameters included in the estimation. For each homotopy step, the Levenberg–Marquardt algorithm adaptively adjusts its step size and typically converges within about 25 iterations according to the defined convergence criteria. Thus, the workflow provides a solid foundation for the model-based design and optimization of versatile chromatographic processes and supports the reliable identification of any nonlinear adsorption equilibria across a wide range of chromatographic modes. Uncertainty quantification is addressed separately within the model validation and risk-assessment workflow already shown by the authors [49]. Due to the more than 30 years of experience with various component systems the benefits are:
- Reliable and robust parameter determination, independent of starting values and without convergence to local minima with a bad data fit.
- A purely numerical comparison is not feasible. Nevertheless, the overall project time was reduced to a few days, compared with the several weeks required by the previously employed approach, which has also been described in the literature by our group [34,50]. The conventional workflow relied on experience-guided parameter studies to obtain suitable initial guesses, followed by weighted nonlinear least-squares fitting of simulated to experimental chromatograms. The simulations were based on an equation-oriented process model solved using a Newton-type iterative solver, while the final refinement of the isotherm parameters was formulated as a nonlinear optimization problem.
- The workflow has often been observed to require substantially less engineering effort than expert-guided manual simulation studies, particularly for multicomponent systems with competitive adsorption effects. In many practical applications, reductions in project execution time of approximately one order of magnitude or more have been achieved.
- Versatile applicability across units, component systems, and component amounts.
- Software-independent, standalone operation.
Due to the growing shortage of available experts personnel, the authors look forward to future project applications and to extending this approach to other unit operations [51]. The homotopy-based versatile isotherm parameter determination feature is finally integrated with an algorithmic process parameter optimizer under a Graphical User Interface (GUI) for daily project work.
Author Contributions
Conceptualization, A.P. and J.S.; methodology, J.L. and A.P.; simulation, modeling and validation, M.B.; writing—original draft preparation, M.B.; writing—review and editing, M.B., A.P., J.L. and J.S.; visualization, M.B.; supervision, J.S.; project administration, J.S. All authors have read and agreed to the published version of the manuscript.
Funding
We acknowledge support by Open Access Publishing Fund of Clausthal University of Technology.
Data Availability Statement
The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.
Acknowledgments
The authors would like to thank their laboratory, mechanical, electrical and institute team for conceptual discussions. The authors would like to thank explicitely Nancy Dietzel and Sven Haroth from Sanofi-Aventis Deutschland GmbH as well as Julien Villaumie, Alexander Klaiber, Markus Juza and Adriano Indolese from Corden Pharma International.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| EMG | Exponentially Modified Gaussian | |
| GUI | Graphical User Interface | |
| IEX | Ion Exchange Chromatography | |
| LA | Linear Amplitude | |
| mAbs | Monoclonal Antibodies | |
| MAD | Median Absolute Deviation | |
| RP | Reversed Phase Chromatography | |
| SMA | Steric Mass Action | |
| Nomenclature | ||
| c | concentration in the bulk phase | g L−1 |
| concentration in the particle pore phase | g L−1 | |
| d | diameter | cm |
| D | dispersion/diffusion coefficient | cm2 s−1 |
| f | competition factor for side components | 1 |
| h | axial step size | cm |
| H | Henry coefficient | 1 |
| k | transfer coefficient | cm s−1 |
| modified equilibrium constant | 1 | |
| KL | Langmuir equilibrium constant | L g−1 |
| Kp | analyte–analyte-interaction parameter | L g−1 |
| Ks | salt-interaction parameter | L mol−1 |
| L | column length | cm |
| M | molar mass | g mol−1 |
| N | axial discrete number | 1 |
| q | concentration in the adsorbed phase | g L−1 |
| r | radial particle coordinate | cm |
| Re | Reynolds number | 1 |
| t | time | s |
| u | velocity | cm s−1 |
| v | valence | 1 |
| volume flow | L s−1 | |
| z | axial column coordinate | cm |
| ε | porosity | 1 |
| η | dynamic viscosity | g cm−1 s−1 |
| Λ | ionic capacity of the resin | mol L−1 |
| ν | stoichiometric replacement coefficient | 1 |
| ρ | density | g L−1 |
| τ | tortuosity | 1 |
| ψ | diffusion hindrance factor | 1 |
| Indices | ||
| ax | axial | |
| c | column | |
| eff | effective | |
| f | film | |
| m | molecular | |
| max | maximum | |
| MC | main component | |
| mod | modifier | |
| SC | side component | |
| i | variable for component | |
| int | interstitial | |
| j | variable for discretization | |
| p | particle | |
| pore | pore | |
| s | salt | |
| tot | total | |
Appendix A
Figure A1.
(a): Concentration of the main component of the recombinant IEX system and the volume fraction of buffer B as a function of time. The black dashed profile represents the initial homotopy step (λ = 0), the red profile the final step (λ = 1) and the blue profiles the intermediate homotopy steps, with decreasing transparency toward the experimental data. Experimental data points are shown in black. (b): Comparison of the chromatograms for the final parameter set; the different optimization runs with varying initial conditions are distinguished by their respective line types. (c): SMA isotherms at three representative salt levels for the final SMA parameter set: blue at the start of the peak, green at the maximum and red at the end of the peak.
References
- Fisher, A.C.; Chatterjee, S.; Madurawe, R.; Tian, G.; Tran, R.; Lee, S.L. FDA Regulatory Experience with Drug Manufacturing Process Models in Approved Applications. Int. J. Pharm. 2026, 702, 127249. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Roush, D.; Asthagiri, D.; Babi, D.K.; Benner, S.; Bilodeau, C.; Carta, G.; Ernst, P.; Fedesco, M.; Fitzgibbon, S.; Flamm, M.; et al. Toward in Silico CMC: An Industrial Collaborative Approach to Model-based Process Development. Biotech Bioeng. 2020, 117, 3986–4000. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wittkopp, F.; Welsh, J.; Todd, R.; Staby, A.; Roush, D.; Lyall, J.; Karkov, S.; Hunt, S.; Griesbach, J.; Bertran, M.-O.; et al. Current State of Implementation of in Silico Tools in the Biopharmaceutical Industry—Proceedings of the 5th Modeling Workshop. Biotechnol. Bioeng. 2024, 121, 2952–2973. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lough, W.J.; Wainer, I.W. High Performance Liquid Chromatography: Fundamental Principles and Practice; CRC Press: Boca Raton, FL, USA, 1995. [Google Scholar]
- Fanali, S.; Chankvetadze, B.; Haddad, P.R.; Poole, C.; Riekkola, M.-L. Liquid Chromatography: Applications; Elsevier: Amsterdam, The Netherlands, 2023. [Google Scholar]
- Schmidt-Traub, H.; Schulte, M.; Seidel-Morgenstern, A. Preparative Chromatography; Wiley-VCH: Weinheim, Germany, 2020. [Google Scholar]
- Ahmed, R. High-Performance Liquid Chromatography (HPLC): Principles, Applications, Versatality, Efficiency, Innovation and Comparative Analysis in Modern Analytical Chemistry and In Pharmaceutical Sciences. Preprints 2024. [Google Scholar] [CrossRef] [Scilit]
- Cserhati, T.; Forgacs, E. Chromatography in Food Science and Technology; CRC Press: Boca Raton, FL, USA, 1999. [Google Scholar]
- Uhl, A.; Broocks, M.; Schulz, T.O.J.; Mendoza, A.M.; Schmidt, A.; Strube, J. Digital Twin Technology for TIDES Process Development and Manufacturing. Processes 2026, 14, 1873. [Google Scholar] [CrossRef] [Scilit]
- Di Stefano, V.; Avellone, G.; Bongiorno, D.; Cunsolo, V.; Muccilli, V.; Sforza, S.; Dossena, A.; Drahos, L.; Vékey, K. Applications of Liquid Chromatography–Mass Spectrometry for Food Analysis. J. Chromatogr. A 2012, 1259, 74–85. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hage, D.S. Affinity Chromatography: A Review of Clinical Applications. Clin. Chem. 1999, 45, 593–615. [Google Scholar] [CrossRef] [Scilit]
- Atapattu, S.N. Applications and Retention Properties of Alternative Organic Mobile Phase Modifiers in Reversed-Phase Liquid Chromatography. J. Chromatogr. Open 2024, 5, 100135. [Google Scholar] [CrossRef] [Scilit]
- Vailaya, A. Fundamentals of Reversed Phase Chromatography: Thermodynamic and Exothermodynamic Treatment. J. Liq. Chromatogr. Relat. Technol. 2005, 28, 965–1054. [Google Scholar] [CrossRef] [Scilit]
- Strube, J.; Ditz, R.; Kornecki, M.; Huter, M.; Schmidt, A.; Thiess, H.; Zobel-Roos, S. Process Intensification in Biologics Manufacturing. Chem. Eng. Process.-Process Intensif. 2018, 133, 278–293. [Google Scholar] [CrossRef] [Scilit]
- Hengelbrock, A.; Probst, F.; Baukmann, S.; Uhl, A.; Tschorn, N.; Stitz, J.; Schmidt, A.; Strube, J. Digital Twin for Continuous Production of Virus-like Particles toward Autonomous Operation. ACS Omega 2024, 9, 34990–35013. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hengelbrock, A.; Baukmann, S.; Uhl, A.; Schmidt, A.; Strube, J. Digital Twin for the Production of hMSC-Derived Extracellular Vesicles for Applications in Cell and Gene Therapy toward Autonomous Operation. ACS Omega 2025, 10, 46659–46681. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Woods, D.R. Rules of Thumb in Engineering Practice; Wiley-VCH: Weinheim, Germany, 2007. [Google Scholar]
- D’Atri, V.; Fekete, S.; Clarke, A.; Veuthey, J.-L.; Guillarme, D. Recent Advances in Chromatography for Pharmaceutical Analysis. Anal. Chem. 2019, 91, 210–239. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Dorsey, J.G.; Dill, K.A. The Molecular Mechanism of Retention in Reversed-Phase Liquid Chromatography. Chem. Rev. 1989, 89, 331–346. [Google Scholar] [CrossRef] [Scilit]
- Janson, J.-C.; Rydén, L. Protein Purification: Principles, High-Resolution Methods, and Applications; John Wiley & Sons: Hoboken, NJ, USA, 1998. [Google Scholar]
- Williams, A.; Frasca, V. Ion-Exchange Chromatography. Curr. Protoc. Protein Sci. 1999, 15, 8.2.1–8.2.30. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Leśko, M.; Kaczmarski, K.; Fornstedt, T.; Samuelsson, J. A Closer Study of Overloaded Elution Bands and Their Perturbation Peaks in Ion-Pair Chromatography. J. Chromatogr. A 2022, 1682, 463491. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Guiochon, G.; Felinger, A.; Shirazi, D.G.G. Fundamentals of Preparative and Nonlinear Chromatography; Elsevier: Amsterdam, The Netherlands, 2006. [Google Scholar]
- Jeansonne, M.S.; Foley, J.P. Review of the Exponentially Modified Gaussian (EMG) Function Since 1983. J. Chromatogr. Sci. 1991, 29, 258–266. [Google Scholar] [CrossRef] [Scilit]
- Cytiva GoSilicoTM Chromatography Modeling Software—Student Package. Available online: https://www.cytivalifesciences.com/en/us/solutions/bioprocessing/products-and-solutions/accelerate-biopharmaceutical-process-development/gosilico-chromatography-modeling-software-student-package (accessed on 10 August 2026).
- Leweke, S.; Von Lieres, E. Chromatography Analysis and Design Toolkit (CADET). Comput. Chem. Eng. 2018, 113, 274–294. [Google Scholar] [CrossRef] [Scilit]
- Gu, T. Parameter Estimation. In Mathematical Modeling and Scale-Up of Liquid Chromatography: With Application Examples; Gu, T., Ed.; Springer International Publishing: Cham, Switzerland, 2015; pp. 39–53. [Google Scholar]
- Galushko, S.V.; Kamenchuk, A.A.; Pit, G.L. Calculation of Retention in Reversed-Phase Liquid Chromatography. J. Chromatogr. A 1994, 660, 47–59. [Google Scholar] [CrossRef] [Scilit]
- Wenig, P.; Odermatt, J. OpenChrom: A Cross-Platform Open Source Software for the Mass Spectrometric Analysis of Chromatographic Data. BMC Bioinform. 2010, 11, 405. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- YMC, C.O. Twin Column Continuous Chromatography Systems. Available online: https://www.ymc.co.jp/en/chromato/contichrom/ (accessed on 14 August 2026).
- YPSO FACTO Ypso-Facto. Available online: https://www.ypsofacto.com/ (accessed on 14 August 2026).
- Schmidt, A.; Lütge, J.; Uhl, A.; Köster, D.; Strube, J. Business Cases for Digital Twins in Biopharmaceutical Manufacturing—Market Overview, Stakeholders, Technologies in 2025 and Beyond. Processes 2025, 13, 1498. [Google Scholar] [CrossRef] [Scilit]
- Tenneti, S.S.R.A. Quality by Design in Bioprocess Development: Integrating Risk, Data, and Regulatory Strategy. IJESTY 2026, 6, 161–167. [Google Scholar] [CrossRef] [Scilit]
- Vetter, F.L.; Strube, J. Need for a Next Generation of Chromatography Models—Academic Demands for Thermodynamic Consistency and Industrial Requirements in Everyday Project Work. Processes 2022, 10, 715. [Google Scholar] [CrossRef] [Scilit]
- Kaczmarski, K. Estimation of Adsorption Isotherm Parameters with Inverse Method—Possible Problems. J. Chromatogr. A 2007, 1176, 57–68. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Åsberg, D.; Leśko, M.; Enmark, M.; Samuelsson, J.; Kaczmarski, K.; Fornstedt, T. Fast Estimation of Adsorption Isotherm Parameters in Gradient Elution Preparative Liquid Chromatography. I: The Single Component Case. J. Chromatogr. A 2013, 1299, 64–70. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Leśko, M.; Åsberg, D.; Enmark, M.; Samuelsson, J.; Fornstedt, T.; Kaczmarski, K. Choice of Model for Estimation of Adsorption Isotherm Parameters in Gradient Elution Preparative Liquid Chromatography. Chromatographia 2015, 78, 1293–1297. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cebulla, D.H. A Homotopy for the Reliable Estimation of Model Parameters in Chromatography Processes. Comput. Chem. Eng. 2025, 199, 109100. [Google Scholar] [CrossRef] [Scilit]
- Cebulla, D.H. Mathematical Modeling and Mixed-Integer Optimization of Multimodal Chromatographic Processes; Technischen Universität Braunschweig: Braunschweig, Germany, 2023. [Google Scholar]
- Chung, S.F.; Wen, C.Y. Longitudinal Dispersion of Liquid Flowing through Fixed and Fluidized Beds. AIChE J. 1968, 14, 857–866. [Google Scholar] [CrossRef] [Scilit]
- Wilson, E.J.; Geankoplis, C.J. Liquid Mass Transfer at Very Low Reynolds Numbers in Packed Beds. Ind. Eng. Chem. Fund. 1966, 5, 9–14. [Google Scholar] [CrossRef] [Scilit]
- Carta, G.; Rodrigues, A.E. Diffusion and Convection in Chromatographic Processes Using Permeable Supports with a Bidisperse Pore Structure. Chem. Eng. Sci. 1993, 48, 3927–3935. [Google Scholar] [CrossRef] [Scilit]
- Danckwerts, P.V. Continuous Flow Systems: Distribution of Residence Times. Chem. Eng. Sci. 1953, 2, 1–13. [Google Scholar] [CrossRef] [Scilit]
- Brooks, C.A.; Cramer, S.M. Steric Mass-Action Ion Exchange: Displacement Profiles and Induced Salt Gradients. AIChE J. 1992, 38, 1969–1978. [Google Scholar] [CrossRef] [Scilit]
- Sattler, K. Thermische Trennverfahren; Wiley-VCH: Weinheim, Germany, 2001. [Google Scholar]
- Carta, G.; Jungbauer, A. Chapter 5—Adsorption Equilibrium. In Protein Chromatography; John Wiley & Sons, Ltd.: Hoboken, NJ, USA, 2020; pp. 159–181. [Google Scholar]
- Li, J. Development and Evaluation of Flexible Empirical Peak Functions for Processing Chromatographic Peaks. Anal. Chem. 1997, 69, 4452–4462. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kalambet, Y.; Kozmin, Y.; Mikhailova, K.; Nagaev, I.; Tikhonov, P. Reconstruction of Chromatographic Peaks Using the Exponentially Modified Gaussian Function. J. Chemom. 2011, 25, 352–356. [Google Scholar] [CrossRef] [Scilit]
- Juckers, A.; Potschka, A.; Strube, J. Advanced Freeze-Drying Modeling: Validation of a Sorption-Sublimation Model. ACS Omega 2025, 10, 16962–16976. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zobel-Roos, S.; Vetter, F.; Scheps, D.; Pfeiffer, M.; Gunne, M.; Boscheinen, O.; Strube, J. Multivariate Parameter Determination of Multi-Component Isotherms for Chromatography Digital Twins. Processes 2023, 11, 1480. [Google Scholar] [CrossRef] [Scilit]
- Schmidt, A.; Hengelbrock, A.; Strube, J. Biopharma 4.0 for Biologics Manufacturing Under Pandemic Constraints. In Biopharmaceutical Manufacturing: Progress, Trends and Challenges; Pörtner, R., Ed.; Springer International Publishing: Cham, Switzerland, 2023; pp. 297–317. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.







