Improving Hydrogen Recovery in the Toluene Hydrodealkylation Process for Benzene Production Through Membrane Technology

and
Chemical Engineering Department, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia
*
Author to whom correspondence should be addressed.
Processes2026, 14(23), 3786;https://doi.org/10.3390/pr14233786 
(registering DOI)
This article belongs to the Special Issue New Applications of Membrane in Separation Processes

Abstract

Hydrodealkylation (HDA) of toluene is an established process for benzene production. However, a large fraction of the excess hydrogen fed to the reactor leaves with methane in the purge gas, increasing the fresh hydrogen demand. In this study, a membrane separation unit was proposed to recover hydrogen from the vapor stream leaving the high-pressure flash drum for recycle to the reactor. The conventional HDA process was simulated under steady-state conditions, and several hydrogen-selective polymeric membranes were evaluated for H2/CH4 separation using a countercurrent hollow-fiber model based on the solution–diffusion mechanism. Copolymer IV, a fluorinated copolymer, was selected for process integration because it provided a favorable hydrogen purity–recovery balance among the adopted membrane cases. The effects of permeate pressure, membrane area, and a two-stage retentate cascade on the membrane-integrated flowsheet were evaluated in terms of compression duty, fuel-gas credit, and incremental capital cost. The preferred single-stage case, operated at a permeate pressure of 5 bar, reduced hydrogen loss in the purge gas by 99% and the fresh hydrogen requirement by 61.3%. The estimated simple payback period for the retrofit was about six months. A two-stage cascade provided no meaningful improvement. Sensitivity analysis showed that hydrogen price was the dominant economic variable. In conclusion, the membrane retrofit shows a substantial improvement in hydrogen recovery in the HDA process.

1. Introduction

Benzene is one of the most important aromatic intermediates in the petrochemical industry and is widely used in the production of plastics, resins, synthetic fibers, detergents, and other chemicals [1]. Hydrodealkylation (HDA) of toluene is a well-established commercial route in which lower-value aromatics are converted into benzene through reaction with hydrogen [2,3,4]. In its simplified form, toluene reacts with hydrogen to produce benzene and methane, which makes the process directly dependent on the availability and efficient use of hydrogen [2,3].
The conventional HDA process has also been widely used as a reference case in chemical process design and economic analysis [2,3]. The process is typically operated at high temperature and moderate pressure, with excess hydrogen supplied to support the desired reaction pathway and reduce the tendency for coke formation and catalyst deactivation [2,3,4]. However, the use of excess hydrogen creates a key limitation in process efficiency. Unreacted hydrogen leaves the high-pressure separator together with methane, and a purge stream is required to prevent methane accumulation in the recycle loop. In a typical design, about 62% of the fresh hydrogen feed is lost with the purge gas to the fuel system [3]. As a result, the conventional configuration achieves the required benzene production but with inefficient hydrogen utilization.
Hydrogen recovery from mixed gas streams is therefore an important design issue in refinery and petrochemical processes. Conventional technologies such as pressure swing adsorption (PSA), cryogenic separation, and absorption methods can be applied to hydrogen purification or recovery, but they often involve trade-offs in capital cost, energy demand, operating complexity, and hydrogen recovery [5,6,7]. PSA is well established for producing high-purity hydrogen, but it requires cyclic operation and multiple adsorption beds [5,6]. Cryogenic recovery can be technically effective for some light-gas separations, but its application is limited by the high refrigeration duty and low-temperature operation required [7]. These considerations motivate the evaluation of alternative separation technologies for hydrogen recovery from HDA off-gas streams.
Membrane separation is a promising option for recovering hydrogen from the vapor leaving the high-pressure separator in the HDA process. Membrane technology offers several advantages, including compact equipment, modular installation, continuous operation, and ease of integration into existing process flowsheets [8,9,10]. Polymeric hollow-fiber membranes have been used commercially for hydrogen recovery from ammonia purge gas and refinery off-gases since the early 1980s [9]. In polymeric membranes, gas transport is commonly described by the solution–diffusion mechanism, in which separation is governed by differences in gas solubility and diffusivity through the selective membrane layer [8,10]. For H2/CH4 separation, membrane performance is strongly influenced by the balance between hydrogen permeance and H2/CH4 selectivity. This balance is important because high hydrogen permeance can reduce membrane area requirements, whereas high selectivity is needed to limit methane permeation and maintain hydrogen-rich permeate streams.
A key challenge in polymeric membrane selection is the well-known trade-off between permeability and selectivity [11]. Highly permeable membranes may provide a large hydrogen flux but insufficient methane rejection, whereas highly selective membranes may require large membrane areas because of their lower permeance. Recent reviews have shown that a wide range of materials, including polymeric, carbon molecular sieve, and mixed matrix membranes, have been investigated for H2/CH4 separation [12,13]. However, the process-level value of a membrane material depends on how its properties interact with operating pressure, membrane area, feed composition, recovery target, and compression requirements. Therefore, membrane selection for HDA hydrogen recovery cannot be based only on intrinsic material properties; it requires the integration of membrane performance with process simulation and economic analysis.
Several membrane modeling approaches have been developed to predict gas separation performance in hollow-fiber modules. Rigorous multicomponent models are especially useful because they can represent the effects of flow pattern, pressure ratio, stage cut, and membrane properties on purity and recovery [14]. For the HDA process, Bouton and Luyben [15] investigated membrane retrofit design, economics, and plantwide control for a single membrane, represented by a ten-cell countercurrent model and placed on the purge stream. The present study differs in four respects. First, the membrane is located in the recycle loop and treats the whole high-pressure separator vapor rather than the purge stream alone. Second, the membrane is described by a countercurrent hollow-fiber model, including bore-side pressure loss, that was verified against published hollow-fiber purity–recovery results [14]. Third, six literature-based membrane transport-property cases, including recently reported fluorinated, polyimide, and polymer-of-intrinsic-microporosity materials, are compared within the same HDA flowsheet, and a two-stage retentate cascade is evaluated against the single-stage retrofit. Fourth, the incremental economic assessment includes feed pretreatment, the loss of fuel-gas credit, and a quantitative sensitivity analysis for hydrogen price, electricity price, and membrane cost. Together, these features provide a process-level basis for selecting the membrane material, location, and operating conditions of an HDA retrofit.
The objective of this study is to evaluate membrane-based hydrogen recovery as a retrofit option for improving hydrogen utilization in the HDA process. Six literature-based membrane transport-property cases are compared within a common steady-state simulation framework. The selected membrane is evaluated in a single-stage retrofit and a two-stage retentate cascade over a range of membrane areas and permeate pressures. The membrane-integrated configurations are compared with the conventional HDA process in terms of fresh hydrogen demand, compressor duty, fuel-gas credit, and incremental capital cost. The economic assessment also examines sensitivity to hydrogen price,, electricity price and membrane cost.

2. Materials and Methods

2.1. Simulation and Evaluation Framework

The methodology is based on steady-state process simulation, membrane modeling, parametric analysis, and incremental economic evaluation. The study is carried out in sequential stages. First, a conventional hydrodealkylation (HDA) process is simulated to establish the base case. Second, a hollow-fiber membrane model is implemented and verified against the published purity–recovery data of Coker et al. [14]. Third, six polymeric membranes are evaluated under H2/CH4 feed conditions representative of the HDA process. Fourth, the selected membrane is integrated into the HDA process flowsheet, and the modified process is compared with the conventional base case. Finally, an incremental economic assessment and sensitivity analysis are performed to evaluate the economic feasibility of the membrane retrofit. The economic assessment basis, results, and sensitivity analysis are presented together in Section 4.
CHEMCAD 8.2 (Chemstations, Inc., Houston, TX, USA) is used as the main process simulation platform for the base-case and membrane-integrated HDA flowsheets. MATLAB (version R2024a, MathWorks, Natick, MA, USA) and spreadsheet calculations are used for post-processing, plotting, and economic calculations. The simulation basis, conventional-process stream data, selected membrane configurations, and reported energy duties are provided in Supplementary File S1.

2.2. Base Case HDA Process Simulation

The conventional HDA process was modeled as the reference case against which all membrane-integrated cases were compared. The process configuration was adapted from the classical HDA design commonly used in chemical process design and economic analysis [2,3]. The main process sections consisted of reaction, gas–liquid separation, and distillation. The CHEMCAD flowsheet for the conventional HDA process is shown in Figure 1.
Figure 1. CHEMCAD flowsheet of the conventional HDA base case used as the reference process. Boxed numbers are CHEMCAD stream identifiers; only selected streams are labeled, so the numbering is not consecutive (streams 12–14 are not labeled). Red and blue arrows denote feed and product streams, respectively; the equipment colors are the default CHEMCAD icon colors and carry no additional meaning.
In the reaction section, toluene reacts with hydrogen to form benzene and methane according to
C 7 H 8 + H 2 → C 6 H 6 + C H 4
The reactor was represented by an adiabatic stoichiometric model at 24 bar, with a specified single-pass toluene conversion of 75% based on the reference HDA simulation of Turton et al. [3]. The outlet temperature was calculated from the energy balance and was 653.7 °C in the conventional case and 679.5 °C in the selected membrane-integrated case. This remains below the 704 °C limit above which hydrocarbon cracking becomes significant [15], so the existing adiabatic reactor can accommodate the methane-depleted recycle at the specified conversion. The specified conversion provided a common basis for comparing hydrogen recovery and incremental retrofit economics. The reactor feed was maintained at a hydrogen-to-toluene molar ratio close to 5.2:1, consistent with conventional HDA process descriptions [2,3]. The reactor effluent was cooled to 38 °C and flashed in a high-pressure separator. The vapor stream leaving this separator contained mainly hydrogen and methane and was selected for membrane-based hydrogen recovery. The liquid stream was sent to a distillation column to recover benzene as the overhead product and unconverted toluene as the bottom recycle stream.
Thermodynamic properties were calculated using the Soave–Redlich–Kwong (SRK) equation of state. Selected process outputs were compared with values calculated using the Peng–Robinson equation of state. Differences in the main process indicators were small; therefore, SRK was adopted for the remaining simulations.

2.3. Membrane Model Description

The membrane unit was represented as an isothermal hollow-fiber gas separation module operated in countercurrent flow. The model was based on the solution–diffusion mechanism and followed the multicomponent hollow-fiber modeling framework reported by Coker et al. [14]. In this formulation, gas permeation is driven by the partial pressure difference across the selective membrane layer. For component i , the molar flux through the membrane was expressed as
J i = Q i p i , F − p i , P
where J i is the molar flux of component i , Q i is the membrane permeance of component i , p i , F is the partial pressure of component i on the feed side, and p i , P is the partial pressure of component i on the permeate side.
The ideal H2/CH4 selectivity was calculated as
α H 2 / C H 4 = Q H 2 Q C H 4
where Q H 2 and Q C H 4 are the hydrogen and methane permeances, respectively.
The membrane performance was evaluated using hydrogen purity, hydrogen recovery, and stage cut. Hydrogen purity in the permeate stream was defined as
y H 2 , P = n ˙ H 2 , P n ˙ P
where y H 2 , P is the hydrogen mole fraction in the permeate, n ˙ H 2 , P is the hydrogen molar flow rate in the permeate, and n ˙ P is the total permeate molar flow rate.
Hydrogen recovery was defined as
R H 2 = n ˙ H 2 , P n ˙ H 2 , F
where n ˙ H 2 , F is the hydrogen molar flow rate in the membrane feed. Stage cut was defined as
θ = n ˙ P n ˙ F
where n ˙ F is the total membrane feed molar flow rate.
The overall material balance around the membrane module was written as
n ˙ F = n ˙ P + n ˙ R
and the component material balance was
n ˙ i , F = n ˙ i , P + n ˙ i , R
where n ˙ R is the total retentate molar flow rate and n ˙ i , R is the retentate molar flow rate of component i .
The principal assumptions of the membrane model were steady-state operation, isothermal conditions, ideal gas behavior, uniform membrane properties, negligible axial dispersion, and pressure-drop treatment based on the hollow-fiber formulation. Based on these assumptions, the membrane model was implemented in CHEMCAD 8.2 using the membrane properties listed in Table 1. Membrane areas and permeate pressures are specified in Table S3 of Supplementary File S1, and the model assumptions and pressure-loss treatment are summarized in Table S5.
Table 1. Selected membrane properties used in the H2/CH4 separation simulations.
To verify the implementation of the membrane model in CHEMCAD 8.2, its predictions were compared with the hydrogen purity–recovery behavior reported by Coker et al. [14] for hollow-fiber membrane gas separation. The comparison was performed at two feed-to-permeate pressure ratios representative of that study, 5.3 (42.4/7.9 bar) and 1.8 (76.9/42.4 bar), using the same permeance values and membrane parameters. The resulting purity–recovery curves, shown in Figure 2, reproduce the trends reported in the literature: hydrogen purity decreases as recovery increases, and the higher pressure ratio gives consistently higher permeate purity at a given recovery. The CHEMCAD results agreed with the published values within 3 percentage points in purity and 2 percentage points in recovery across both pressure ratios, confirming that the model captures the essential separation behavior before being applied to the vapor stream leaving the high-pressure separator. Application of the membrane model to HDA assumes that the adopted permeances and selectivities remain representative of the cooled, conditioned feed. These properties may vary with pressure, temperature, and mixture composition, affecting the predicted purity and recovery; experimental confirmation under representative HDA membrane-feed conditions remains necessary.
Figure 2. Hydrogen purity versus recovery predicted by the membrane model at two feed-to-permeate pressure ratios, used to verify the model against the hollow-fiber gas separation behavior reported by Coker et al. [14].

2.4. Membrane Materials and Operating Conditions

Six membrane transport-property cases were selected from the literature to represent a wide range of hydrogen permeance and H2/CH4 selectivity. These comprised a reference hollow-fiber membrane case, an ultrathin polyimide thin-film composite membrane, two high-permeance fluorinated polymers, a higher-selectivity fluorinated copolymer, and a highly selective thermally cross-linked polymer of intrinsic microporosity. All cases were evaluated using the same membrane model and screening conditions. The adopted transport properties were treated as fixed inputs, without adjustment for differences in the source measurement conditions or membrane architecture. The comparison therefore evaluates the adopted property cases rather than membrane performance measured under identical conditions. The membrane data were obtained from published literature and implemented in the membrane model using reported gas permeances or stated permeance estimates. The TX-AOPIM-1-390-24 entries in Table 1 correspond to converting the published H2 permeability of 455 Barrer and the H2/CH4 selectivity of 455 using an effective layer thickness of 70 µm, the upper end of the 60–70 µm film-thickness range reported in [19], giving approximately 6.5 and 0.014 GPU, respectively. This assumed thickness is a screening input, not a reported commercial module specification. In mixed-gas feeds, sorption and diffusion may differ from pure-gas behavior, changing permeance and selectivity and hence the predicted hydrogen purity and recovery [8].
The membrane feed was defined as the vapor stream leaving the high-pressure separator in the base case HDA process. The nominal membrane feed conditions were 38 °C and 23.9 bar, with an approximate composition of 60 mol% H2 and 40 mol% CH4. The principal operating variables were permeate pressure and membrane area. Permeate pressure was evaluated at 3, 5, 10, and 15 bar, while hollow-fiber membrane area was varied from 2000 to 6000 m2. These ranges were selected to assess the effect of pressure ratio and membrane size on hydrogen purity, hydrogen recovery, fresh hydrogen demand, compressor power, and economic performance.
A membrane-only parametric analysis was first conducted for all six membranes to compare their purity and recovery behavior. After the preferred membrane was identified, the membrane unit was integrated into the HDA flowsheet for process-level evaluation.

2.5. Membrane-Integrated HDA Configuration

The selected membrane was integrated into the conventional HDA process by treating the vapor stream leaving the high-pressure separator. Before entering the membrane unit, this vapor stream was passed through a pretreatment section consisting of a knockout drum, a coalescing filter, and an activated carbon guard bed. This pretreatment section was included to represent practical protection of the membrane from liquid carryover and trace contaminants [20,21].
The overall HDA flowsheet includes H2, CH4, benzene, and toluene. Membrane transport was approximated as binary H2/CH4 separation under a conditioned-feed assumption, consistent with the stand-alone membrane optimization of Bouton and Luyben [15]. The proposed pretreatment addresses liquid carryover and condensable contaminants but does not establish complete removal of aromatic vapors. Residual aromatic permeation and its effects on membrane properties were not modeled; the membrane predictions are therefore conditional on the assumed conditioned feed. In the simulation, the pretreatment section was represented by an ideal component separator that removes the aromatics from the membrane feed and returns them to the distillation feed, consistent with the conditioned-feed assumption (Supplementary Table S1).
In the single-stage membrane configuration, the pretreated vapor stream was fed to the membrane unit. The hydrogen-rich permeate stream was compressed and recycled to the HDA process, while the retentate stream was sent to the fuel gas line. The modified process was configured to maintain a reactor feed hydrogen-to-toluene ratio comparable to that used in the conventional base case, thereby ensuring that differences between the two flowsheets reflected the effect of hydrogen recovery rather than a change in reactor feed basis.
A two-stage retentate cascade was also evaluated after identifying the preferred single-stage membrane case. In this configuration, the retentate from the first membrane stage was sent to a second membrane stage to recover additional hydrogen. The permeate streams from both stages were combined and compressed for recycle, while the final retentate was directed to the fuel gas line. This additional configuration was included to determine whether further hydrogen recovery could justify the additional membrane area, compression requirement, and capital cost.
The comparison between the single-stage and two-stage configurations was therefore used to assess whether the additional separation stage could provide enough hydrogen recovery to offset the added membrane area, compression duty, and capital cost.

3. Results and Discussion

This section presents and discusses the technical results of the conventional HDA simulation, membrane material evaluation and selection, membrane-integrated HDA process, and selected cascade evaluation. The results are organized to show how membrane-based hydrogen recovery affects fresh hydrogen demand, hydrogen loss in the purge stream, utility demand, and compressor duty. The economic evaluation of the membrane retrofit is presented separately in Section 4.

3.1. Base Case HDA Process Performance

The conventional HDA process was first simulated as the reference case for evaluating the membrane retrofit. The base case recovered 105.079 kmol/h of benzene in the product stream at a mole fraction of 0.9962. The fresh hydrogen requirement was 286.0 kmol/h, while 178.01 kmol/h of hydrogen left the process with the purge gas. This confirms that the conventional flowsheet achieved the benzene production objective but lost a substantial amount of recoverable hydrogen with the methane-rich vapor stream. The principal simulation results for the conventional HDA base case are summarized in Table 2.
Table 2. Principal results for the conventional HDA base case.
The purge-gas flow reported in Table 2 refers to the combined final fuel-gas outlet, which contains methane, residual hydrogen, benzene, and toluene. Its methane content includes methane introduced with the fresh gas, whereas the reported benzene product flow excludes benzene leaving with the fuel gas. On this basis, the outlet streams close the reaction balance: net methane formation (123.0 kmol/h in the fuel gas minus 15.0 kmol/h in the fresh gas), total benzene output (105.1 kmol/h in the product plus 2.9 kmol/h in the fuel gas) and net toluene consumption (108.7 kmol/h fed minus 0.7 kmol/h leaving) are each approximately 108.0 kmol/h, consistent with Equation (1) (Supplementary Table S2).

3.2. Membrane Material Evaluation and Selection

The membrane parametric evaluation was conducted before process integration. The membrane evaluation showed the dependence of separation performance on the balance between hydrogen permeance and H2/CH4 selectivity. Lower permeate pressure increased the transmembrane driving force for hydrogen permeation and improved hydrogen recovery. Higher stage cut increased hydrogen recovery but reduced permeate hydrogen purity. Highly permeable membranes provided high flux but allowed greater methane permeation, while very selective membranes restricted methane transport but required larger effective area because of lower permeance. This trade-off is important for the HDA retrofit because methane slip into the permeate increases the recycle load and compression requirement, whereas very low permeance increases the membrane area needed to recover hydrogen. Therefore, the preferred membrane should provide sufficient hydrogen flux while maintaining enough H2/CH4 selectivity to limit methane recycle.
To further illustrate the membrane separation behavior without repeating all six material curves, three representative membranes were selected from the full membrane evaluation and plotted in Figure 3 in terms of hydrogen recovery and permeate purity as functions of stage cut. Teflon AF 2400 represents the high-permeance but low-selectivity case, 6FDA-ODA represents an intermediate-performance case, and Copolymer IV represents the preferred membrane identified from the full membrane evaluation.
Figure 3. Effect of stage cut on hydrogen recovery and hydrogen purity for three representative membranes at a feed pressure of 23.9 bar and permeate pressure of 5 bar: (a) Teflon AF 2400, (b) 6FDA-ODA, and (c) Copolymer IV.
As shown in Figure 3, increasing stage cut increased hydrogen recovery but reduced permeate hydrogen purity because a larger fraction of the feed permeated through the membrane, allowing more methane to pass with hydrogen. The extent of this purity loss depended strongly on H2/CH4 selectivity, which explains why Copolymer IV maintained a more favorable balance than Teflon AF 2400.
Figure 4 compares the hydrogen purity–recovery behavior of the six selected membranes over a screening feed-flow range of 300–2000 kmol/h. The dashed operating region was defined to represent membrane cases that combine high hydrogen recovery with acceptable hydrogen purity for recycle to the HDA process. The comparison shows that the selected materials did not perform equally over the stated screening range. TX-AOPIM-1-390-24 provided very high hydrogen purity but remained limited by low hydrogen recovery because of its very low permeance. Teflon AF 2400 and Hyflon AD 60 approached high recovery, but their lower H2/CH4 selectivity resulted in lower permeate purity. In contrast, Copolymer IV entered the desired operating region and achieved 93.4% H2 purity and 93.9% H2 recovery at the nominal screening flow of 1100 kmol/h. In this illustrative screen, Copolymer IV provided the most favorable balance between purity and recovery among the six candidates. The nominal screening feed flow of 1100 kmol/h was based on the vapor leaving the high-pressure separator in the conventional HDA process (Stream 8). The flow of 304.219 kmol/h reported in Table 2 refers to the final fuel-gas outlet (Stream 16). In the membrane-integrated process, the membrane treats the whole pretreated separator vapor, but closing the recycle loop changes its flow and composition; in the selected 5 bar case the membrane feed was 817.143 kmol/h with an H2 mole fraction of 0.7980, compared with 1101.0 kmol/h and 0.59 in the conventional separator vapor (Supplementary Table S3). The selection is nevertheless governed by the transport properties themselves. Copolymer IV is the only case that combines an H2/CH4 selectivity above 100 with an H2 permeance of several hundred GPU (Table 1). The low-selectivity cases (Hyflon AD 60 and Teflon AF 2400) give lower permeate purity at any feed condition, whereas the lower-permeance cases would require proportionally larger membrane area to permeate the same hydrogen flow at the same driving force, by factors of about 3.7 for 6FDA-ODA, 7 for Permea® H2, and more than 100 for TX-AOPIM-1-390-24. A change in feed flow or composition shifts the operating point along each curve but is not expected to change the selection.
Figure 4. Hydrogen purity–recovery comparison of the selected membranes over a screening feed-flow range of 300–2000 kmol/h. The highlighted operating region represents high hydrogen recovery with acceptable purity for recycle to the HDA process. At the nominal separator-vapor feed flow of 1100 kmol/h, Copolymer IV achieved 93.4% H2 purity and 93.9% H2 recovery. The inset shows an enlarged view of the operating region. Open markers denote the simulated feed-flow points along each curve, and the larger filled markers denote the nominal feed flow of 1100 kmol/h for each membrane.
From a membrane selection perspective, the results show that high permeance alone was not sufficient to ensure a favorable purity–recovery balance in the screening comparison. Teflon AF 2400 and Hyflon AD 60 offered high hydrogen permeance, but their relatively low selectivity led to greater methane permeation and weaker hydrogen purity control. By contrast, TX-AOPIM-1-390-24 provided very high selectivity and excellent hydrogen purity, but its low permeance would require substantially larger membrane area to achieve comparable hydrogen throughput. Among the six membranes considered in the screening comparison, Copolymer IV provided a favorable balance between hydrogen permeance and H2/CH4 selectivity. This balance allowed strong hydrogen recovery while limiting the methane slip observed for low-selectivity, high-permeance materials. The position of Copolymer IV within the defined operating region in Figure 4 further supports its selection, since it combined acceptable hydrogen purity with high hydrogen recovery at the nominal vapor-stream flow, unlike the highly selective but low-recovery TX-AOPIM membrane and the high-permeance but low-purity fluorinated polymers. Therefore, Copolymer IV was carried forward for process integration and economic evaluation at the simulated HDA operating conditions.
Copolymer IV has been fabricated and tested as a laboratory composite membrane [17,18]. Its long-term performance under industrial HDA conditions has not been established in these studies. Practical application requires sustained mixed-gas testing to assess the retention of permeance and selectivity, tolerance to residual aromatic vapors, and module durability.

3.3. Single-Stage Membrane-Integrated HDA Process

After the membrane-only parametric evaluation, Copolymer IV was selected for process integration. The membrane was added to the HDA flowsheet to recover hydrogen from the vapor stream. The hydrogen-rich permeate was compressed and recycled to the reactor feed system, while the methane-rich retentate was routed to the fuel-gas line. The membrane-integrated HDA flowsheet is shown in Figure 5.
Figure 5. CHEMCAD flowsheet of the membrane-integrated HDA process. The red box labeled “Retrofit” encloses the units added to the conventional flowsheet (pretreatment, membrane, and permeate compressor). Boxed numbers are CHEMCAD stream identifiers; only selected streams are labeled, so the numbering is not consecutive. Red and blue arrows denote feed and product streams, respectively; the equipment colors are the default CHEMCAD icon colors and carry no additional meaning.
The membrane-integrated cases were configured to maintain a reactor feed hydrogen-to-toluene ratio comparable to that of the conventional base case, so that the comparison reflected the effect of hydrogen recovery rather than a change in reactor feed basis.
Figure 6 shows the effect of permeate pressure and membrane area on the fresh hydrogen requirement of the single-stage membrane-integrated process. Increasing permeate pressure increased the fresh hydrogen requirement for all membrane areas because the lower pressure ratio reduced hydrogen permeation. Increasing membrane area reduced the fresh hydrogen requirement at a given permeate pressure, but the effect of membrane area became greater at higher permeate pressure. This behavior shows that membrane area and permeate pressure cannot be optimized independently. A lower permeate pressure improves the separation driving force, but it also lowers the pressure of the recovered permeate stream and increases the downstream compression requirement for recycle.
Figure 6. Effect of permeate pressure and membrane area on the fresh hydrogen requirement for the single-stage Copolymer IV membrane-integrated HDA process.
For a membrane area of 4000 m2, decreasing the permeate pressure from 15 to 5 bar sharply reduced the fresh hydrogen requirement and the hydrogen loss in the purge stream. However, the improvement in hydrogen recovery was accompanied by a substantial increase in compressor power. The 5 bar case reduced fresh hydrogen consumption from 286.0 to 110.7 kmol/h, equivalent to a 61.3% reduction, and lowered the hydrogen loss in the purge stream to 1.815 kmol/h. To provide a direct technical comparison between the conventional and the membrane-based HDA processes, Table 3 summarizes the main process changes obtained for the selected single-stage Copolymer IV case operated at 5 bar permeate pressure and 4000 m2 membrane area. The comparison focuses on hydrogen use, purge/fuel-gas flow, utility demand, and compressor power. Figure 7 illustrates these changes.
Table 3. Technical comparison between the conventional and selected membrane-based HDA processes.
Figure 7. Comparison of hydrogen use, fuel-gas flow, and utility demand for the conventional and the membrane-based HDA processes.
As illustrated in Figure 7 and quantified in Table 3, the membrane-based process substantially reduced the fresh hydrogen requirement, fuel-gas flow, and total heating and cooling utility demand. The fresh hydrogen requirement decreased by 61.3%, while the fuel-gas flow decreased by 58.8%. Heating and cooling duties decreased by 23.3% and 14.3%, respectively, while total compressor power increased from 41.91 to 1192.60 kW due to recompression of the recovered hydrogen-rich permeate. The combined heating and cooling load in Table 3 is the sum of heat supplied and removed and does not represent overall energy consumption. On an energy basis, the additional compressor electricity (about 4.1 GJ/h) is small compared with the 42.4 GJ/h (LHV) reduction in imported hydrogen and the 12.0 GJ/h reduction in heating duty. The fuel-gas export also decreases, because the recovered hydrogen is no longer burned as fuel; these energy flows are listed in Table 3. The detailed effect of permeate pressure on the 4000 m2 Copolymer IV case is reported in Table 4.
Table 4. Effect of permeate pressure on the process performance of the single-stage Copolymer IV case at 4000 m2.
Although the 10 bar case had lower compressor power, the 5 bar case provided a much larger hydrogen saving and a much lower hydrogen loss in the purge stream, close to the values at 3 bar (Table 4). The 5 bar and 4000 m2 case was selected as the preferred single-stage operating condition because it gave the highest annual net benefit among the permeate pressures evaluated at this membrane area, as discussed in Section 4.2. A direct technical comparison between the 5 bar and 10 bar cases is presented in Table 5.
Table 5. Technical comparison of the two leading single-stage Copolymer IV cases.
The comparison between the 5 bar and 10 bar cases illustrates the central retrofit trade-off. Reducing permeate pressure increases the H2 partial pressure driving force and improves hydrogen recovery, but it also increases the compression ratio required to return the permeate to the recycle system. As shown in Table 5, lowering the permeate pressure from 10 to 5 bar reduced the hydrogen in the purge stream from 24.421 to 1.815 kmol/h but increased the total compressor power from 579.1 to 1192.6 kW. Therefore, the preferred permeate pressure cannot be identified from hydrogen recovery alone, and the associated compression duty and capital cost must also be considered, as discussed in Section 4.2.

3.4. Selected Two-Stage Cascade Evaluation

A selected two-stage retentate cascade was evaluated to determine whether additional recovery from the first stage retentate could provide a meaningful technical or economic improvement. The best cascade case used Copolymer IV in the first stage and Permea® H2 in the second stage, with permeate pressures of 5 bar in each stage and a total membrane area of 4250 m2.
As shown in Figure 8 and Table 6, the cascade case achieved nearly the same fresh hydrogen requirement and hydrogen loss as the preferred single-stage case, but required a slightly larger membrane area. For this particular H2/CH4 separation, the single-stage Copolymer IV membrane already reduced the hydrogen content in the purge stream to a very low level. Consequently, the second membrane stage treated a retentate stream with limited remaining recoverable hydrogen. Although a multistage arrangement can be useful when a significant amount of valuable component remains in the first stage retentate, the additional stage in this case provided no meaningful hydrogen recovery improvement while increasing membrane area and compressor power. Therefore, from a technical perspective, the additional cascade stage offered no meaningful advantage over the preferred single-stage configuration under the conditions examined in this study. The economic implications of the cascade are discussed in Section 4.3.
Figure 8. Hydrogen use and hydrogen loss for the base case, preferred single-stage case, and best selected cascade case.
Table 6. Technical comparison of the preferred single-stage case and the best selected cascade case.
In both membrane cases, the benzene product increased from 105.079 to 108.132 kmol/h at the same purity, because the pretreatment returns the aromatics contained in the separator vapor to the distillation section instead of the fuel gas (Section 2.5). This additional benzene was not credited in the economic assessment, so the reported net benefit does not include it.

4. Economic Evaluation

This section presents the incremental economic evaluation of the membrane retrofit. The economic assessment basis is described first, followed by the economic performance of the single-stage membrane-integrated cases, the economic evaluation of the selected two-stage cascade, and the sensitivity analysis of the preferred case.

4.1. Economic Assessment Basis

The economic assessment was performed on an incremental retrofit basis. The conventional HDA process was used as the reference case, and each membrane-integrated case was evaluated in terms of the additional capital cost and the annual economic benefit relative to that reference. This basis was selected because the membrane system was treated as an addition to an existing HDA process rather than as a complete plant replacement.
The base case recycle compressor was assumed to remain in service. Therefore, the incremental capital expenditure included the membrane module cost, the pretreatment package cost, and the installed cost of the additional compressor required to raise the recovered hydrogen-rich permeate stream to the suction pressure of the existing recycle compressor. The existing compressor then provided the final pressure increase to the original recycle pressure.
The annual hydrogen saving was calculated from the fresh hydrogen requirements obtained from the CHEMCAD simulations of the base case and membrane-integrated cases:
S H 2 = F H 2 , b a s e − F H 2 , m e m P H 2 t o p
where S H 2 is the annual hydrogen saving, F H 2 , b a s e and F H 2 , m e m are the fresh hydrogen molar flow rates for the base case and membrane-integrated cases, respectively, P H 2 is the hydrogen price on a molar basis, and t o p is the annual operating time.
The annual net benefit was calculated by combining the annual hydrogen saving, utility cost difference, fuel credit difference, membrane replacement cost, and pretreatment operating cost:
B n e t = S H 2 + Δ C u t i l + Δ C f u e l − C m e m , r e p − C p r e t r e a t , O M Δ
where B n e t is the annual net benefit, Δ C u t i l is the annual utility cost difference relative to the base case, Δ C f u e l is the annual fuel credit difference, C m e m , r e p is the annual membrane replacement cost, estimated as the installed membrane area multiplied by the membrane cost per unit area and divided by the membrane replacement interval, and C p r e t r e a t , O M is the annual pretreatment operating and maintenance cost. The utility cost and fuel credit differences were defined relative to the base case, so that a positive value increases the annual net benefit and a negative value reduces it.
The incremental capital expenditure was calculated as
C A P E X i n c = C m e m , m o d u l e + C p r e t r e a t + C c o m p , a d d
where C m e m , m o d u l e is the membrane module cost, C p r e t r e a t is the installed pretreatment cost, and C c o m p , a d d is the installed cost of the additional compressor required by the membrane retrofit.
The simple payback period was calculated as the ratio of the incremental capital expenditure to the annual net benefit, and the incremental return on investment (incremental ROI) was calculated as the ratio of the annual net benefit to the incremental capital expenditure, expressed as a percentage. The incremental ROI therefore measures the annual return on the retrofit investment only, not on the capital of the existing plant; a value above 100% corresponds to a simple payback period shorter than one year.
The economic assumptions are summarized in Table 7. The membrane cost of 100 USD/m2 was adopted as a screening estimate based on the installed cost reported for a carbon molecular sieve membrane unit [22], not a supplier quotation for Copolymer IV.
Table 7. Economic assumptions used in the membrane-integrated HDA evaluation.
The economic indicators were used only for preliminary comparison between membrane-integrated cases. The module-cost assumption and availability of the selected copolymer at industrial scale require independent confirmation.
Depreciation, taxation, financing structure, inflation, salvage value, and discounted cash flow effects were not included because the economic scope was limited to a preliminary incremental assessment of the membrane retrofit.

4.2. Economic Performance of the Single-Stage Membrane-Integrated Process

The conventional HDA process was used as the economic reference case. For the base case, the annual hydrogen cost was 11.440 million USD/y, the annual fuel credit was 2.015 million USD/y, and the total annual operating cost was 10.330 million USD/y. The economic performance of each membrane-integrated case was evaluated relative to these values.
The economic response of the single-stage membrane-integrated process followed the same general trade-off as the fresh hydrogen requirement shown in Figure 6, but was not identical to the hydrogen recovery trend. As shown in Figure 9a, annual net benefit was highest in the low-to-moderate permeate pressure range, with the 5 bar cases giving the highest values; at this pressure, the net benefit varied little for membrane areas of 3000–6000 m2, and 4000 m2 was retained as the reference area. Figure 9b shows that simple payback generally improved as permeate pressure increased up to approximately 10 bar, before becoming less favorable at 15 bar for most areas. This indicates that the condition with the highest annual benefit did not necessarily provide the shortest payback. Lower permeate pressure increased hydrogen recovery and hydrogen cost saving, but it also increased compressor duty and incremental capital cost. As a result, the economically preferred case was governed by the combined effect of hydrogen savings, fuel credit, compressor power, and capital cost rather than by hydrogen recovery alone.
Figure 9. Effect of permeate pressure and membrane area on (a) annual net benefit and (b) simple payback for the single-stage Copolymer IV membrane-integrated HDA process.
For the selected single-stage case at 5 bar and 4000 m2, the annual net benefit reached 5.888 million USD/y, the highest among the permeate pressures evaluated at 4000 m2 (Table 8). Since the economic assessment was performed on a preliminary incremental retrofit basis, the reported payback and incremental ROI should be interpreted as screening-level indicators rather than final investment metrics.
Table 8. Effect of permeate pressure on the economic performance of the single-stage Copolymer IV case at 4000 m2.
At 4000 m2, the 5 bar case was selected based on its higher annual net benefit (5.888 million USD/y versus 5.296 million USD/y at 10 bar) and lower fresh-hydrogen demand (110.70 versus 133.30 kmol/h). The 10 bar alternative required lower incremental CAPEX (2.120 versus 3.070 million USD) and offered higher incremental ROI (249.8% versus 191.8%) and shorter simple payback (0.400 versus 0.521 y). The preference for 5 bar therefore reflects the annual-net-benefit objective under the adopted economic assumptions. A direct economic comparison is presented in Table 9.
Table 9. Economic comparison of the two leading single-stage Copolymer IV cases.
The higher annual net benefit at 5 bar reflects hydrogen savings after accounting for the operating-cost and fuel-credit differences included in the assessment. The higher initial investment is evaluated separately through simple payback and incremental ROI.

4.3. Economic Evaluation of the Two-Stage Cascade

The economic performance of the best selected two-stage cascade case described in Section 3.4 was compared with that of the preferred single-stage case. As shown in Table 10, the cascade case required a slightly higher incremental CAPEX of 3.095 million USD, compared with 3.070 million USD for the single-stage case, and its annual net benefit was also slightly lower at 5.880 million USD/y. Consequently, the simple payback increased from 0.521 to 0.526 y, and the incremental ROI decreased from 191.8% to 190.0%. Therefore, under the conditions examined in this study, the additional cascade stage was not justified, because hydrogen recovery remained essentially unchanged despite the added membrane area and incremental capital cost.
Table 10. Economic comparison of the preferred single-stage case and the best selected cascade case.

4.4. Sensitivity Analysis

A sensitivity analysis was conducted for the selected single-stage Copolymer IV case at 5 bar and 4000 m2. The selected variables were hydrogen price, electricity price, and membrane cost because they directly affect hydrogen savings, compression-related operating cost, and membrane-related capital and replacement costs. Each variable was varied separately while keeping the remaining assumptions fixed. The effects were evaluated using incremental return on investment and simple payback period as the main economic indicators.
The reference case had an annual net benefit of 5.888 million USD/y, an incremental CAPEX of 3.070 million USD, a simple payback of 0.521 y, and an incremental ROI of 191.8%. Among the variables investigated, hydrogen price had the strongest influence on economic performance because the main economic benefit of the retrofit came from reducing fresh hydrogen demand. Therefore, the economic indicators should be viewed in relation to the selected assumptions for hydrogen price, membrane cost, replacement interval, pretreatment cost, and fuel credit.
Increasing the hydrogen price from 0.5 to 4.5 USD/kg H2 increased incremental ROI from approximately 9.1% to 374.5% and reduced simple payback from 11.03 to 0.267 y. By comparison, electricity price and membrane cost produced more moderate effects. This indicates that the selected design maintained positive economic performance over the investigated electricity-price and membrane-cost ranges, but its overall economic viability remained strongly dependent on the assumed value of recovered hydrogen.
Figure 10 shows the corresponding sensitivity trends for incremental ROI and simple payback. The much steeper response to hydrogen price confirms that the economic performance is governed mainly by the value of recovered hydrogen, while electricity price and membrane cost have more moderate effects over the investigated ranges. The numerical ranges and their effects on incremental ROI and simple payback are summarized in Table 11.
Figure 10. Sensitivity of incremental return on investment (incremental ROI) and simple payback to (a) hydrogen price, (b) electricity price, and (c) membrane cost for the selected single-stage Copolymer IV case at 5 bar and 4000 m2.
Table 11. Summary of the sensitivity analysis for the selected reference case.
The tested membrane-cost range is not a verified commercial price range for Copolymer IV; the economic estimates remain conditional on the assumed membrane cost.

4.5. Key Process and Economic Findings

The results demonstrate that membrane-based hydrogen recovery can substantially improve hydrogen utilization in the HDA process while preserving benzene production performance. The preferred configuration was the single-stage Copolymer IV membrane case operated at 5 bar permeate pressure and a membrane area of 4000 m2. This case reduced the fresh hydrogen requirement by 61.3%, reduced purge hydrogen loss by approximately 99.0%, and achieved a calculated annual net benefit of 5.888 million USD/y with a payback period below one year under the stated screening assumptions. The preferred case was selected using annual net benefit as the primary criterion, with simple payback and incremental ROI reported as complementary indicators.

5. Conclusions

This study evaluated membrane-based hydrogen recovery as a retrofit option for improving hydrogen utilization in the hydrodealkylation process for benzene production. A steady-state simulation framework was developed for the conventional and membrane-integrated HDA flowsheets, and six polymeric membranes were evaluated for H2/CH4 separation under conditions relevant to the vapor stream leaving the high-pressure separator. The conventional base case showed the need for hydrogen recovery, as 178.01 kmol/h of hydrogen left the process with the purge gas while fresh hydrogen demand remained 286.0 kmol/h.
The membrane screening showed that hydrogen recovery and purity depended on the adopted permeances, selectivities, and operating conditions. Copolymer IV provided the most favorable purity–recovery balance among the six cases and was therefore selected for process integration and economic evaluation. This preference is conditional on the adopted transport properties and does not establish superiority under matched mixed-gas HDA conditions.
For the single-stage membrane-integrated process, the preferred case was obtained at a permeate pressure of 5 bar and a membrane area of 4000 m2. This configuration reduced the fresh hydrogen requirement from 286.0 to 110.7 kmol/h, corresponding to a 61.3% reduction, and reduced the hydrogen loss in the purge stream to 1.815 kmol/h. Under the assumed prices and module costs, the case achieved a calculated annual net benefit of 5.888 million USD/y, with an incremental CAPEX of 3.070 million USD, a simple payback period of 0.521 y, and an incremental ROI of 191.8%. Although operation at 10 bar provided a shorter payback and higher incremental ROI, the 5 bar case was preferred for its higher annual net benefit under the adopted economic assumptions.
The selected two-stage retentate cascade did not provide a meaningful improvement over the preferred single-stage configuration. The best cascade case achieved nearly the same fresh hydrogen requirement and purge hydrogen loss, but required a slightly larger membrane area, slightly higher incremental CAPEX, and a slightly lower annual net benefit. The sensitivity analysis further showed that hydrogen price was the dominant economic variable, whereas electricity price and membrane cost had more moderate effects over the investigated ranges. Overall, the results indicate that membrane integration can improve hydrogen utilization in the HDA process while preserving benzene production performance, provided that hydrogen recovery is balanced against compression duty, fuel credit, and incremental capital cost. The predicted retrofit benefits assume that the specified single-pass toluene conversion can be maintained. Kinetic modeling is needed to assess the reactor response to changes in recycle composition. Future work should focus on experimental validation under HDA-relevant mixed-gas conditions, long-term membrane stability, detailed pretreatment and module costing, dynamic process behavior, and comparison with alternative hydrogen recovery technologies.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/pr14233786/s1, File S1: Simulation specifications and supporting process data.

Author Contributions

Conceptualization, M.I.A. and A.A.A.-R.; methodology, M.I.A. and A.A.A.-R.; software, M.I.A.; validation, M.I.A. and A.A.A.-R.; formal analysis, M.I.A.; investigation, M.I.A.; resources, A.A.A.-R.; data curation, M.I.A.; writing—original draft preparation, M.I.A.; writing—review and editing, M.I.A. and A.A.A.-R.; visualization, M.I.A.; supervision, A.A.A.-R.; project administration, A.A.A.-R. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Ongoing Research Funding Program (ORF-2026-2220), King Saud University, Riyadh, Saudi Arabia.

Data Availability Statement

The supporting simulation specifications and tabulated process data are provided in the article and Supplementary File S1. Additional simulation data are available from the corresponding author upon reasonable request.

Acknowledgments

This research was funded by the Ongoing Research Funding Program, King Saud University, Riyadh, Saudi Arabia.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
CAPEXCapital expenditure
CHEMCADChemical Engineering Computer Aided Design
CWCooling water
GPUGas permeation unit
HDAHydrodealkylation
LHVLower heating value
O&MOperating and maintenance
PIMPolymer of intrinsic microporosity
PpPermeate pressure
PSAPressure swing adsorption
ROIReturn on investment
SRKSoave–Redlich–Kwong

References

  1. Franck, H.G.; Stadelhofer, J.W. Industrial Aromatic Chemistry; Springer: Berlin, Germany, 1988. [Google Scholar]
  2. Douglas, J.M. Conceptual Design of Chemical Processes; McGraw-Hill: New York, NY, USA, 1988. [Google Scholar]
  3. Turton, R.; Bailie, R.C.; Whiting, W.B.; Shaeiwitz, J.A.; Bhattacharyya, D. Analysis, Synthesis, and Design of Chemical Processes, 4th ed.; Prentice Hall: Upper Saddle River, NJ, USA, 2012. [Google Scholar]
  4. Folkins, H.O. Benzene. In Ullmann’s Encyclopedia of Industrial Chemistry; Wiley-VCH: Weinheim, Germany, 2000. [Google Scholar] [CrossRef] [Scilit]
  5. Sircar, S. Pressure swing adsorption. Ind. Eng. Chem. Res. 2002, 41, 1389–1392. [Google Scholar] [CrossRef] [Scilit]
  6. Sircar, S.; Golden, T.C. Purification of hydrogen by pressure swing adsorption. Sep. Sci. Technol. 2000, 35, 667–687. [Google Scholar] [CrossRef] [Scilit]
  7. Adhikari, S.; Fernando, S. Hydrogen membrane separation techniques. Ind. Eng. Chem. Res. 2006, 45, 875–881. [Google Scholar] [CrossRef] [Scilit]
  8. Koros, W.J.; Fleming, G.K. Membrane-based gas separation. J. Membr. Sci. 1993, 83, 1–80. [Google Scholar] [CrossRef] [Scilit]
  9. Baker, R.W. Future directions of membrane gas separation technology. Ind. Eng. Chem. Res. 2002, 41, 1393–1411. [Google Scholar] [CrossRef] [Scilit]
  10. Sanders, D.F.; Smith, Z.P.; Guo, R.; Robeson, L.M.; McGrath, J.E.; Paul, D.R.; Freeman, B.D. Energy-efficient polymeric gas separation membranes for a sustainable future: A review. Polymer 2013, 54, 4729–4761. [Google Scholar] [CrossRef] [Scilit]
  11. Robeson, L.M. The upper bound revisited. J. Membr. Sci. 2008, 320, 390–400. [Google Scholar] [CrossRef] [Scilit]
  12. Zhou, R.; Pan, Y.; Xing, W.; Xu, N. Advanced microporous membranes for H2/CH4 separation: Challenges and perspectives. Adv. Membr. 2021, 1, 100011. [Google Scholar] [CrossRef] [Scilit]
  13. Huang, L.; Xing, Z.; Zhuang, X.; Wei, J.; Ma, Y.; Wang, B.; Jiang, X.; He, X.; Deng, L.; Dai, Z. Polymeric Membranes and Their Derivatives for H2/CH4 Separation: State of the Art. Sep. Purif. Technol. 2022, 297, 121504. [Google Scholar] [CrossRef] [Scilit]
  14. Coker, D.T.; Freeman, B.D.; Fleming, G.K. Modeling multicomponent gas separation using hollow-fiber membrane contactors. AIChE J. 1998, 44, 1289–1302. [Google Scholar] [CrossRef] [Scilit]
  15. Bouton, G.R.; Luyben, W.L. Optimum economic design and control of a gas permeation membrane coupled with the hydrodealkylation (HDA) process. Ind. Eng. Chem. Res. 2008, 47, 1221–1237. [Google Scholar] [CrossRef] [Scilit]
  16. Lee, J.; Park, C.-Y.; Kong, C.-I.; Lee, J.-H.; Moon, S.-Y. Ultrathin Water Cast Polymer Membranes for Hydrogen Purification. ACS Appl. Mater. Interfaces 2022, 14, 7292–7300. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Okamoto, Y.; Zhang, H.; Mikeš, F.; Koike, Y.; He, Z.; Merkel, T.C. New perfluoro-dioxolane-based membranes for gas separations. J. Membr. Sci. 2014, 471, 412–419. [Google Scholar] [CrossRef] [Scilit]
  18. Okamoto, Y.; Du, Q.; Koike, K.; Mikeš, F.; Merkel, T.C.; He, Z.; Zhang, H.; Koike, Y. New amorphous perfluoro polymers: Perfluorodioxolane polymers for use as plastic optical fibers and gas separation membranes. Polym. Adv. Technol. 2016, 27, 33–41. [Google Scholar] [CrossRef] [Scilit]
  19. Huang, M.; Lu, K.; Wang, Z.; Bi, X.; Zhang, Y.; Jin, J. Thermally Cross-Linked Amidoxime-Functionalized Polymers of Intrinsic Microporosity Membranes for Highly Selective Hydrogen Separation. ACS Sustain. Chem. Eng. 2021, 9, 9426–9435. [Google Scholar] [CrossRef] [Scilit]
  20. Anderson, C.L.; Siahaan, A. Case study: Membrane CO2 removal from natural gas, Grissik gas plant, Sumatra, Indonesia. In Proceedings of the Regional Symposium on Membrane Science & Technology, Johor Bahru, Malaysia, 24–25 April 2004. [Google Scholar]
  21. U.S. Environmental Protection Agency. Chapter 1: Carbon Adsorbers. In Control Cost Manual, 7th ed.; U.S. Environmental Protection Agency: Washington, DC, USA, 2018. [Google Scholar]
  22. Rahimalimamaghani, A.; Ramezani, R.; Tanaka, D.A.P.; Gallucci, F. Carbon Molecular Sieve Membranes for Selective CO2/CH4 and CO2/N2 Separation: Experimental Study, Optimal Process Design, and Economic Analysis. Ind. Eng. Chem. Res. 2023, 62, 19116–19132. [Google Scholar] [CrossRef] [Scilit]
  23. Towler, G.; Sinnott, R. Chemical Engineering Design: Principles, Practice and Economics of Plant and Process Design, 1st ed.; Butterworth-Heinemann: Burlington, MA, USA, 2008. [Google Scholar]
  24. Alhadhrami, K.; Albalawi, A.; Hasan, S.; Elshurafa, A.M. Modeling Green Hydrogen Production Using Power-to-X: Saudi and German Contexts. Int. J. Hydrogen Energy 2024, 64, 1040–1051. [Google Scholar] [CrossRef] [Scilit]
  25. Marafiq. Power Tariff. Available online: https://www.marafiq.com.sa/en/partnering-with-us/power-tariff/ (accessed on 13 April 2026).
  26. Abdullah, M.F.P.; Alharbi, A.D. Energy Price Update: Saudi Aramco Raises Feedstock & Fuel Prices; Riyad Capital: Riyadh, Saudi Arabia, 2024. [Google Scholar]
  27. Marafiq. Water Tariff. Available online: https://www.marafiq.com.sa/en/partnering-with-us/water-tariff/ (accessed on 13 April 2026).
  28. Alkandari, S.H.; Castro-Dominguez, B. Advanced and Sustainable Manufacturing Methods of Polymer-Based Membranes for Gas Separation: A Review. Front. Membr. Sci. Technol. 2024, 3, 1390599. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.