Study on Abnormal Gas Accumulation and Spatial Distribution of Temperature Field in Backfill Mining Face

,
,
,
,
,
and
1
Liuzhuang Mining Co., Ltd., China Coal Xinji Energy Co., Ltd., Fuyang 236218, China
2
School of Safety Science and Engineering, Anhui University of Science and Technology, Huainan 232001, China
3
State Key Laboratory of Coal Mine Safety Technology, CCTEG Shenyang Research Institute Co., Ltd., Fushun 113122, China
4
Geological Exploration Engineering Branch, Huainan Mining Group Co., Ltd., Huainan 232052, China
This article belongs to the Special Issue Reservoir and Downhole Numerical Simulation

Abstract

Backfill mining is a safe and environmentally friendly mining technology that effectively recovers coal resources under buildings, railways, and water bodies and improves resource recovery efficiency. However, materials including adhesives and fly ash used in the backfilling process release volatile organic gases and trace indicator gases, which easily accumulate in areas such as the return air corner, trigger abnormal gas sensor alarms, and disrupt mine safety monitoring and early warning systems as well as normal production at the working face. To address this problem, taking the No. 33 upper 32 backfill working face of a coal mine as the engineering background, numerical models of the working face under three working conditions (post-backfilling completion, isolation, and hydraulic support advancing) were constructed. The spatial distribution characteristics of the airflow field, abnormal gases, and temperature field under each working condition were systematically studied, and the influence pattern of working face air velocity on abnormal gas accumulation and local high temperature was explored. The results showed that abnormal gases were mainly distributed in low-velocity zones of the working face, namely the return air corner under all working conditions and the isolation zone under the isolation condition. When hydraulic support advancing started from the intake air corner, the increase in abnormal gas concentration at the return air corner was significantly smaller than that when advancing started from the return air corner; the spatial distribution patterns of simulated abnormal gases are qualitatively consistent with the locations of on-site gas sensor abnormal alarms. Local high temperature appeared in the isolation zone: with an airflow temperature of 25 °C and a backfill body wall temperature of 40 °C, the maximum local temperature reached 32.06 °C. Appropriately increasing the working face air velocity could effectively reduce abnormal gas concentration and mitigate local high temperature in the isolation zone. When the air velocity rose from 1.5 m/s to 2 m/s, the temperature of the isolation zone decreased markedly; when the air velocity was further increased to 2.5 m/s, the magnitude of temperature reduction in the local high-temperature zone became limited. This study can provide a basis for developing prevention and control technologies for abnormal gas sensor alarms in backfill working faces, and provide support for safe production in underground coal mines.

1. Introduction

Backfill mining is a core component of the green coal mining technology system [1,2,3]. Using solid wastes such as coal gangue and fly ash as backfill materials to replace underground coal resources, this technology can effectively control surface deformation while mitigating environmental pollution, and has remarkable advantages in safe coal resource extraction, ecological environment protection, solid waste disposal and utilization, and engineering disaster prevention and control [4,5]. Coal gangue, fly ash, paste, and high-water materials applied in backfill mining all fall into the category of inorganic backfill materials [6,7,8]. However, field practice of underground backfill mining shows that reactions between different backfill materials generate toxic and harmful gases, which interfere with the normal monitoring of underground mine electrochemical CO sensors and lead to false alarms [9,10,11,12,13]. With the continuous development of science and technology, various polymer backfill materials, including phenolic, polyurethane, and urea-formaldehyde materials, have been gradually applied in areas such as high caving zones, working face end corners, and behind-support spaces. During the expansion and solidification process, these polymer backfill materials not only release a certain amount of heat, but also produce a variety of toxic and harmful gases, including carbon monoxide (CO), hydrogen cyanide (HCN), nitrogen oxides (NOx), formaldehyde (CH2O), sulfur dioxide (SO2), and ammonia (NH3) [14]. Our previous field investigation and experimental analysis further revealed that the adhesive used in the isolation process is the primary source of abnormal gas emissions, and the emitted alkane species (particularly C5H12 and C6H14) cause significant cross-interference on catalytic combustion-type CH4 sensors, leading to false alarms in the return air corner [15].
In recent years, many scholars have conducted extensive research on the gas generation characteristics of backfill materials composed of coal gangue and fly ash. Ma, H.Y. [16] analyzed the gas generation laws of paste backfill materials with different mixing ratios and the influence of temperature on gas release, and found that the gas variation trends during the reaction of paste backfill materials from different coal mines are similar. Zheng, Q.W. et al. [17] reported that acidic substances such as sulfuric acid feature strong corrosivity and high reactivity. These acids continuously react with impurity components, including sulfides inherent in coal gangue, producing highly toxic gases with pungent odors such as hydrogen sulfide (H2S). Phosphogypsum can also generate abnormal gases in backfill systems: phosphoric acid reacts with metals and carbonates to produce hydrogen and carbon dioxide, respectively; fluorides react with acidic media like phosphoric acid to form hydrogen fluoride (HF) [18,19]. Abnormal gases are released through three primary mechanisms: physical desorption, chemical reaction, and microbial metabolism. Physical desorption refers to the process where deformation and expansion of pores and fractures inside solid waste materials drive the escape of trapped free gas [20]. Chemical reactions describe the formation of toxic gases when impurities in solid wastes undergo pyrolysis, redox reactions, or acid-base reactions under high-temperature, high-humidity, and acidic conditions [21,22]. Microbial metabolism means environmental microorganisms utilize impurity salts and organic matter in solid wastes through metabolic processes, thereby generating hazardous by-product gases [23].
Many scholars have carried out extensive research on the gas concentration field, airflow field, and temperature field in goafs. Zhuo, H. [24] established a coal spontaneous combustion model for composite goafs in shallow-buried contiguous coal seam groups, and conducted numerical simulations on the distribution characteristics of gas (O2, CO) concentration field, flow field and temperature field within the region. Combined with the upper limit of air leakage intensity and the lower limit of oxygen concentration, the scope of dangerous zones of coal spontaneous combustion in composite goafs was determined. Based on steady seepage experiments on four types of broken rock samples with different average particle sizes, Qin, Y.P. et al. [25] constructed a mathematical model of coal spontaneous combustion in goafs under moving coordinates, and obtained the distribution laws of O2 concentration field and temperature field in goafs at different mining advance speeds. Shi, G.Q. et al. [26] adopted an optimized permeability distribution model of goafs and unsteady numerical simulation to acquire the distribution characteristics of oxygen concentration in goafs at different mining stages. Hao, Y. [27] adopted numerical simulation to investigate the effects of different air volumes and gas emission intensities on spontaneous combustion dangerous zones in goafs. To clarify the distribution characteristics of the three spontaneous combustion zones in goafs, Xu, C.F. [28] simulated and analyzed the flow field of the goaf in a fully mechanized caving face via numerical simulation software, and identified the division of the three spontaneous combustion zones. Shao, G.A. [29] proposed a research method based on large-diameter borehole sampling and oxygen concentration analysis, and discussed the distribution characteristics of spontaneous combustion dangerous zones under the condition of gas extraction through large-diameter boreholes. Lu, W. et al. [30] analyzed the complex causes of the initiation and development of coal spontaneous combustion, and established coal spontaneous combustion models under various air leakage conditions. It was pointed out that the difficulty of coal seam fire extinguishing lies in removing massive accumulated heat. Based on the actual field conditions of longwall goafs, Zhang, J. et al. [31] constructed a three-dimensional transient non-equilibrium thermodynamic CFD model to study the temperature rise of coal spontaneous combustion and inertization schemes in longwall goafs. Zhang, J.L. [32] built an oxygen consumption rate coupling model, a flow model for porous media areas, and a spatial distribution model of porosity, and adopted segmented numerical simulation to analyze the characteristics of the three spontaneous combustion zones under multiple air leakage paths. Yue, N.F. [33] comprehensively considered residual coal thickness, oxygen volume fraction, and air leakage intensity, determined the threshold values of dangerous zone parameters through theoretical calculation, and put forward a division method for spontaneous combustion dangerous zones in goafs. Chai, J.M. [34] investigated the coupling effects of oxygen flow field and gas concentration field on the distribution of the three spontaneous combustion zones in goafs. Zheng, L.Y. [35] experimentally determined the upper and lower limit oxygen concentrations for coal spontaneous combustion, and adopted the oxygen concentration method to reveal the three-dimensional distribution characteristics of the three spontaneous combustion zones in the goaf of a shallow-buried extra-thick coal face.
In summary, previous scholars have carried out extensive research on the gas generation law of backfill materials, release mechanisms of abnormal gases, and distribution characteristics of gas concentration and temperature fields in goafs. Nevertheless, while the composition and cross-interference effects of abnormal gases have been identified [15], systematic studies on their migration and accumulation patterns under different ventilation and operating conditions in backfill working faces remain relatively scarce. There is a lack of direct theoretical support for the targeted control of gas sensor false alarms in backfill working faces. In this paper, FLUENT numerical simulation is adopted to systematically investigate the accumulation law of abnormal gas and the distribution characteristics of temperature fields under various working conditions of the working face. The influences of different ventilation wind speeds on abnormal gas distribution and temperature field evolution are further discussed. The research results can provide theoretical references for formulating prevention measures against gas sensor false alarms and guaranteeing safe mining of working faces.

2. Working Face Parameters and Model Establishment

2.1. Engineering Overview

The No. 33 upper 32 working face of the target coal mine is located at the east wing of the northern No. 3 mining area at the −210 m level. The working face has a strike length of 379 m and a dip length ranging from 52 m to 165 m (average: 108 m). The coal seam within the working face features stable occurrence, with a thickness of 2.5–3.5 m and an average value of 3.1 m.
A U-shaped negative pressure ventilation system is adopted. The cross-sectional area of both the intake and return roadways is 15.2 m2, and the actual air supply volume of the working face is 1350 m3/min. Under the isolation process, the ventilation path of the area to be backfilled is as follows: intake airway → opening at the face tail (tail beams of #4, #5, and #6 hydraulic supports are fully opened) → backfilling zone of the working face → opening at the face head (tail beams of #4, #5, and #6 hydraulic supports are fully opened) → return airway.
The actual measured airflow rate at the working face is approximately 1350 m3/min, corresponding to an air velocity of about 1.5 m/s. The 2.0 and 2.5 m/s cases are designed to evaluate the effect of increased ventilation on abnormal gas dispersion.

2.2. Physical Modeling and Meshing

Based on the actual conditions of the No. 33 upper 32 working face, geometric models under different working conditions (post-backfilling completion, isolation, and hydraulic support advancing) were established, as shown in Figure 1.
Figure 1. Working face modeling.
Given that abnormal gases are mainly emitted from the zone between the backfill body and the isolation baffle, a porous medium model was applied to this region to simulate gas permeation through the isolation cloth. The porous medium parameters are as follows: porosity = 0.9, viscous resistance coefficient = 2.111 × 108 m−2, inertial resistance coefficient = 0 m−1, and permeability = 4.74 × 10−9 m2. The porosity is selected based on the typical range of non-woven geotextile isolation cloth used in backfill mining, and the viscous resistance is derived from permeability using the Forchheimer equation.
To simplify the numerical simulation procedure, the species transport model was enabled in FLUENT, and the abnormal gas was simplified as a single component (C5H12) for the simulation [15]. The abnormal gas introduced into the CFD domain as a volumetric mass source term was determined through a combined procedure of laboratory characterization, field measurement, and CFD calibration. Simultaneous thermal analysis coupled with mass spectrometry (STA-MS) and headspace gas chromatography–mass spectrometry (GC-MS) was performed on the polyurethane–isocyanate adhesive used in the isolation process. The results confirmed that alkanes dominated the volatile products, accounting for 87.57% of the total peak area, with C5H12, C6H14, C7H16, and C8H16 as the principal species. C5H12 was selected as the representative species for the simulation because it is both a major component and produces the strongest cross-interference response on catalytic combustion CH4 sensors, as confirmed by controlled interference tests using analytical-grade reagents in 10 L Tedlar bags [15].
Portable gas detector readings were then collected at representative monitoring points during post-backfilling, isolation, and support-advancing operations. In Table 1, the field CH4 equivalent readings reached 0.32–0.34% at the return air corner under the post-backfilling condition, 0.44% behind support #30 on the roof side during support advancing, and up to 1.00% behind support #65 under the isolation condition. On-site gas chromatographic analysis confirmed that the true CH4 concentration was only 0.01–0.03% and CO was approximately 5 ppm, so the elevated detector readings were entirely attributable to cross-interference from adhesive VOCs rather than genuine gas accumulation. The laboratory calibration curves of C5H12 volume fraction versus equivalent CH4 sensor response (Figure 2) were used to back-calculate the equivalent C5H12 concentrations at each monitoring point, and the volumetric mass source term q was calibrated by running preliminary CFD cases with progressively adjusted source strengths and comparing the predicted C5H12 mass fraction at the return air corner and other key locations with the back-calculated values. The source-strength range of 0.002–0.006 kg/(m3·s) for the non-advancing zone and 0.004–0.016 kg/(m3·s) for the support-advancing zone was adopted because, under these ranges, the CFD-predicted high-concentration zones and their relative magnitudes across the three operating conditions matched the field observations. At a source strength of 0.004 kg/(m3·s) and an inlet velocity of 1.5 m/s, the predicted C5H12 mass fraction at the return air corner was approximately 0.14, which is consistent with the field-observed sensor response after applying the laboratory interference calibration. The upper bound of 0.016 kg/(m3·s) corresponds to the peak instantaneous release during support movement, when the accumulated gas behind the isolation cloth is suddenly exposed to the ventilation airflow.
Table 1. Field-measured CH4 equivalent readings at representative monitoring points under three operating conditions.
Figure 2. Cross-interference effect of VOC gases at different concentrations on the catalytic combustion CH4 sensor.
The simulation was conducted using ANSYS Fluent 24.2 with a pressure-based 3D steady-state solver. The RNG k-ε turbulence model was adopted to capture the recirculation and vortex structures in the working face. The energy equation was activated to account for the temperature field. The pressure–velocity coupling was solved using the SIMPLE algorithm, and second-order upwind discretization was applied for all governing equations to ensure solution accuracy.
Unstructured grids were used to discretize the computational domain during meshing. For the post-backfilling completion condition, the number of grid cells was 1,482,045 with a grid quality of 0.9921358; for the isolation condition, the number of grid cells was 1,417,503 with a grid quality of 0.9921064; and for the hydraulic support advancing condition, the number of grid cells was 1,432,563 with a grid quality of 0.99921053.
A hybrid unstructured mesh consisting of tetrahedral, hexahedral, and pyramidal transition cells was employed to discretize the computational domain. A mesh-sensitivity study was conducted using the isolation condition as the representative case, with the abnormal-gas source rate, inlet velocity, and backfill-wall temperature fixed at 0.004 kg/(m3·s), 1.5 m/s, and 35 °C, respectively.
Three meshes with nominal global cell sizes of 0.40, 0.30, and 0.20 m were generated. The corresponding cell numbers were 710,375, 1,455,941, and 4,710,625, respectively. The pressure drops across the working-face region, the C5H12 mass fraction at the return-corner monitoring location, and the maximum C5H12 mass fraction in the computational domain were selected as the mesh-sensitivity variables. Compared with the fine mesh, the medium mesh produced differences of 2.33%, 2.61%, and 1.73% in these quantities, respectively. The maximum difference was 2.61%, which is within the acceptable engineering range of 5% (Figure 3). Therefore, further mesh refinement had no appreciable influence on the principal flow and species-transport results.
The medium mesh contained approximately 69.1% fewer cells than the fine mesh, and was therefore selected for the subsequent simulations as a compromise between numerical accuracy and computational cost. Applying the medium-mesh settings to the three geometrical conditions resulted in 1,482,045 cells for the post-backfilling condition, 1,417,503 cells for the isolation condition, and 1,432,563 cells for the hydraulic-support-advancing condition.
Automatic inflation was not activated in the present model, and no separate prismatic layers were generated. The regular near-wall cells were hexahedral cells. Near-wall turbulence was treated using the standard wall-function approach.
Figure 3. Mesh independence study: comparison of pressure drops, return-corner C5H12 mass fraction, and maximum C5H12 mass fraction across three mesh densities.
After meshing, the relevant physical parameters and boundary conditions were precisely defined. For the post-backfilling completion condition, the emission rate of abnormal gases exhibits dynamic characteristics owing to the limited total volume of abnormal gases. To explore the distribution patterns of abnormal gases and the temperature field under varying air velocity conditions, multiple air velocity scenarios were set at the inlet boundary. The detailed parameter settings and boundary condition configurations are presented in Table 2.
Table 2. Related boundary condition settings.

3. Results and Analysis

3.1. Airflow Distribution Characteristics of the Working Face

There are significant differences in operation modes and technological processes between backfill mining and conventional mining. Compared with conventional mining, backfill mining includes an isolation process and a backfilling process, both of which take a long time to implement. Therefore, targeted simulations must be carried out separately to accurately analyze the variation characteristics of airflow, abnormal gas distribution, and temperature field under different working conditions. In this study, the air velocity at the inlet boundary was set to 1.5 m/s, and airflow contour maps at different heights (1 m, 2 m, 3 m) parallel to the floor were selected for analysis.
To ensure the smooth progress of the isolation operation, a full-pressure ventilation system was adopted for ventilation in the area to be backfilled. The 4th, 5th, and 6th hydraulic supports counting backward from the face tail of the working face served as air inlets for the backfilling zone, while the 4th, 5th, and 6th hydraulic supports at the face head served as air outlets. Figure 4 shows the schematic diagram of the airflow field of the working face under the isolation and post-backfilling completion working conditions.
Figure 4. Airflow simulation under isolation and post-backfilling completion working conditions. (a) Wind velocity distribution contour at Z = 1 m height parallel to the floor under the isolation working condition. (b) Wind velocity distribution contour at Z = 2 m height parallel to the floor under the isolation working condition. (c) Wind velocity distribution contour at Z = 3 m height parallel to the floor under the isolation working condition. (d) Wind velocity distribution contour at Z = 1 m height parallel to the floor under the post-backfilling completion working condition. (e) Wind velocity distribution contour at Z = 2 m height parallel to the floor under the post-backfilling completion working condition. (f) Wind velocity distribution contour at Z = 3 m height parallel to the floor under the post-backfilling completion working condition.
As shown in Figure 4, the airflow field distribution patterns of the working face under the isolation condition and the post-backfilling completion condition exhibit high consistency across different heights. In areas near the coal wall, the air velocity is generally elevated due to the change in airflow direction. Under the post-backfilling completion condition, the air velocity in most regions of the working face can reach 2 m/s, while under the isolation condition, the air velocity in most regions can exceed 1.6 m/s.
For the post-backfilling completion condition, the scope of low-velocity zones at the intake air corner, return air corner, and the area in front of the isolation baffle expands significantly with increasing working face height. For the isolation condition, the airflow velocity rises slightly when airflow enters the isolation zone from the working face due to flow steering; however, as the airflow continues toward the return air side, the velocity gradually decreases. Restricted by the ventilation mode, the overall air velocity in the areas in front of and behind the isolation baffle is low under the isolation condition, and the range of the low-velocity zone expands markedly with increasing working face height. Consistent with the post-backfilling completion condition, the low-velocity zones at the intake and return air corners under the isolation condition also show a trend of expansion as the working face height increases. Abnormal gases tend to stagnate and accumulate in these low-velocity zones, thus forming high-risk areas for abnormal gas accumulation.
After the backfill raw materials solidify, the working face enters the production stage. For this stage, airflow simulations of the working face were conducted under two scenarios: hydraulic support advancing starting from the return air corner and advancing starting from the intake air corner. The distribution patterns of the airflow field under the two advancing modes were analyzed through simulation, with emphasis on the distribution characteristics of low-velocity zones. Figure 5 presents the schematic diagrams of the working face airflow field at different heights (1 m, 2 m, 3 m) parallel to the floor for the two advancing initiation positions, respectively.
Figure 5. Airflow simulation during hydraulic support advancing at the return and intake air corners. (a) Wind velocity distribution contour at Z = 1 m height parallel to the floor during hydraulic support advancing at the return air corner. (b) Wind velocity distribution contour at Z = 2 m height parallel to the floor during hydraulic support advancing at the return air corner. (c) Wind velocity distribution contour at Z = 3 m height parallel to the floor during hydraulic support advancing at the return air corner. (d) Wind velocity distribution contour at Z = 1 m height parallel to the floor during hydraulic support advancing at the intake air corner. (e). Wind velocity distribution contour at Z = 2 m height parallel to the floor during hydraulic support advancing at the intake air corner. (f) Wind velocity distribution contour at Z = 3 m height parallel to the floor during hydraulic support advancing at the intake air corner.
As shown in Figure 5, when hydraulic support advancing starts from the return air corner, the airflow field of the working face is generally consistent with that during the backfilling process. Airflow in the advanced support zone is significantly obstructed by the hydraulic supports and the isolation baffle. The extent of the high-velocity zone behind the isolation baffle expands gradually with increasing working face height. Furthermore, owing to the high air velocity in the area behind the isolation baffle near the roof, the instantaneous release of abnormal gases during support advancing diffuses along the airflow direction to the return air corner, which may consequently trigger false gas sensor alarms.
When hydraulic support advancing is initiated from the intake air corner, the high-velocity zone behind the isolation baffle likewise expands with increasing working face height. Along the path from the advanced support zone in front of the isolation baffle to the return air corner, under the influence of airflow diversion caused by the hydraulic supports and the isolation baffle, the airflow velocity near the roof in the area in front of the isolation baffle exhibits a gradual downward trend.
The velocity vector distribution (Figure 6) shows distinct vortices and recirculation zones behind the hydraulic supports and around the isolation baffle. These flow structures promote lateral mixing between abnormal gas and fresh airflow, enhancing the dilution effect on the intake side.
Figure 6. Velocity vector distribution under different working conditions. (a) Working condition after filling end; (b) Isolated conditions; (c) Frame shifting condition.

3.2. Distribution Characteristics of Abnormal Gas Concentration in the Working Face

For the zone after backfilling completion, three working conditions with abnormal gas emission rates of 0.006 kg/(m3·s), 0.004 kg/(m3·s) and 0.002 kg/(m3·s) were defined in this study. Abnormal gas distribution contours at different heights parallel to the floor and different distances perpendicular to the floor were extracted for analysis. The distribution patterns of abnormal gases under the post-backfilling completion condition are illustrated in Figure 7 and Figure 8.
Figure 7. Comparison of Abnormal Gas Distribution at Different Heights Parallel to the Floor. (a) Abnormal gas distribution contour at Z = 1 m height parallel to the floor under an emission rate of 0.004 kg/(m3·s). (b) Abnormal gas distribution contour at Z = 2 m height parallel to the floor under an emission rate of 0.004 kg/(m3·s). (c) Abnormal gas distribution contour at Z = 3 m height parallel to the floor under an emission rate of 0.004 kg/(m3·s). (d) Abnormal gas distribution contour at Z = 3 m height parallel to the floor under an emission rate of 0.002 kg/(m3·s). (e) Abnormal gas distribution contour at Z = 3 m height parallel to the floor under an emission rate of 0.006 kg/(m3·s).
Figure 8. Comparison of Abnormal Gas Distribution at Different Distances Perpendicular to the Floor in Front of the Isolation Baffle. (a) Abnormal gas distribution contour at 0.1 m from the isolation baffle perpendicular to the floor under an emission rate of 0.006 kg/(m3·s). (b) Abnormal gas distribution contour at 0.1 m from the isolation baffle perpendicular to the floor under an emission rate of 0.004 kg/(m3·s). (c) Abnormal gas distribution contour at 0.4 m from the isolation baffle perpendicular to the floor under an emission rate of 0.004 kg/(m3·s). (d) Abnormal gas distribution contour at 0.7 m from the isolation baffle perpendicular to the floor under an emission rate of 0.004 kg/(m3·s). (e) Abnormal gas distribution contour at 0.1 m from the isolation baffle perpendicular to the floor under an emission rate of 0.002 kg/(m3·s).
As can be seen from Figure 7 and Figure 8, the accumulation area of abnormal gases shows a gradual expansion trend with the increase in abnormal gas emission rate. Abnormal gases are mainly concentrated at the return air corner and on the side near the return air corner in front of the isolation baffle. In the area close to the roof, abnormal gas accumulation is most severe in the middle of the working face, while the accumulation phenomenon gradually weakens when transitioning from the middle of the working face to the return air corner.
As shown in Figure 7c–e, when airflow enters the working face from the intake airway, the high-velocity zone at the height of 3 m covers a wider range. Therefore, after abnormal gases are emitted from behind the isolation baffle, they are rapidly carried into the middle area of the working face by high-velocity airflow. Along the path from the middle of the working face to the return air corner, the airflow velocity decreases gradually, and the abnormal gases cannot be diluted in time, resulting in the accumulation of most abnormal gases in the middle of the working face. Eventually, a distribution pattern of “high concentration in the middle and low concentration at both ends” is formed at the height of 3 m.
Furthermore, as indicated in Figure 8, in the area in front of the isolation baffle, the closer the distance to the isolation baffle, the more prominent the abnormal gas accumulation. On the side near the return air corner in front of the isolation baffle, abnormal gas accumulation near the floor is relatively severe. The core reason is that abnormal gases emitted from the intake side are transported to the return side under the action of airflow, while the air velocity at the return side is low. In addition, owing to the large molecular weight of abnormal gases, they tend to settle and accumulate on the floor when the effects of airflow buoyancy and turbulent diffusion are weakened.
Affected by the isolation process, gas sensors in the area behind each support of the isolation baffle show abnormal conditions to varying degrees. During the implementation of the isolation process, the air permeability of the isolation cloth used for auxiliary backfilling materials has a significant impact on abnormal gas accumulation: the better the air permeability of the isolation cloth, the greater the emission rate of abnormal gases. Figure 9 and Figure 10 present the abnormal gas distribution contours under different emission rates at varying heights parallel to the floor and varying distances perpendicular to the floor under the isolation working condition, respectively.
Figure 9. Contour maps of abnormal gas distribution at different heights parallel to the floor under isolation condition. (a) Abnormal gas distribution at height Z = 1 m with gas emission rate of 0.004 kg/(m3·s). (b) Abnormal gas distribution at height Z = 2 m with gas emission rate of 0.004 kg/(m3·s). (c) Abnormal gas distribution at height Z = 3 m with gas emission rate of 0.004 kg/(m3·s). (d) Abnormal gas distribution at height Z = 3 m with gas emission rate of 0.006 kg/(m3·s). (e) Abnormal gas distribution at height Z = 3 m with gas emission rate of 0.002 kg/(m3·s).
Figure 10. Contour maps of abnormal gas distribution at different distances perpendicular to the floor behind the isolation baffle under isolation condition. (a) Abnormal gas distribution at 0.5 m behind the isolation baffle with gas emission rate of 0.006 kg/(m3·s). (b) Abnormal gas distribution at 0.5 m behind the isolation baffle with gas emission rate of 0.002 kg/(m3·s). (c) Abnormal gas distribution at 0.5 m behind the isolation baffle with gas emission rate of 0.004 kg/(m3·s). (d) Abnormal gas distribution at 1.5 m behind the isolation baffle with gas emission rate of 0.004 kg/(m3·s). (e) Abnormal gas distribution at 2.5 m behind the isolation baffle with gas emission rate of 0.004 kg/(m3·s).
As shown in Figure 9 and Figure 10, due to the overall low wind speed in the isolated area, the concentration and distribution range of abnormal gas on planes at different heights parallel to the floor and at different distances perpendicular to the floor were basically consistent under the same abnormal gas emission rate. Along the direction from the isolation baffle to the backfill wall, the concentration of abnormal gas presented a gradual decreasing trend. In addition, affected by the airflow direction, the abnormal gas concentration on the return air side of the isolated area was significantly higher than that on the intake air side, and the abnormal gas tended to accumulate on the return air side.
The simulation results indicate that the application of low-permeability isolation cloth in isolation operations can significantly reduce the abnormal gas concentration in the isolated area and at the return air corner, thus effectively reducing the false alarm risk of gas sensors during isolation operations. However, low-permeability isolation cloth restricts the dissipation of abnormal gas, resulting in massive gas accumulation in the confined area between the isolation cloth and the backfill, which increases the probability of false alarms of gas sensors during the support moving process. In comparison, when high-permeability isolation cloth is adopted, abnormal gas dissipates more easily, which alleviates its accumulation in the area between the isolation cloth and the backfill. In summary, scientifically selecting the permeability of the isolation cloth is of great significance for reducing false alarms of gas sensors under different working conditions.
Figure 11 and Figure 12 show the contour maps of abnormal gas distribution at a height of 3 m parallel to the floor of the working face and at different distances perpendicular to the floor in front of the isolation baffle during support moving starting from the return air corner, under different gas emission rates.
Figure 11. Contour maps of abnormal gas distribution at 3 m height parallel to the floor during support moving at the return air corner under different gas emission rates. (a) Abnormal gas distribution with gas emission rate of 0.016 kg/(m3·s). (b) Abnormal gas distribution with gas emission rate of 0.012 kg/(m3·s). (c) Abnormal gas distribution with gas emission rate of 0.008 kg/(m3·s). (d) Abnormal gas distribution with gas emission rate of 0.004 kg/(m3·s).
Figure 12. Contour maps of abnormal gas distribution at different distances perpendicular to the floor during support moving at the return air corner under different gas emission rates. (a) Abnormal gas distribution at 0.1 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.016 kg/(m3·s). (b) Abnormal gas distribution at 0.1 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.012 kg/(m3·s). (c) Abnormal gas distribution at 0.1 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.008 kg/(m3·s). (d) Abnormal gas distribution at 0.1 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.004 kg/(m3·s). (e) Abnormal gas distribution at 0.4 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.004 kg/(m3·s). (f) Abnormal gas distribution at 0.7 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.004 kg/(m3·s).
As shown in Figure 11 and Figure 12, after the support moving operation, a large amount of abnormal gas escaped rapidly, which significantly increased the wind speed in the moved support area at a height of 3 m. The high-speed airflow carried a large volume of abnormal gas quickly to the return air corner, and the abnormal gas concentration at the return air corner increased continuously with the rise of the gas emission rate in the moved support area. When the abnormal gas emission rate in the moved support area reached 0.016 kg/(m3·s), the maximum local mass fraction of abnormal gas in the return air corner exceeded 0.35, which was approximately twice the concentration under the post-filling condition. In addition, the airflow direction near the intake air side of the working face did not change significantly, so the abnormal gas concentration distribution from the support moving area to the intake air side showed no significant difference from that under the post-filling condition. It should be noted that the maximum C5H12 mass fraction exceeding 0.35 observed under certain conditions represents a local peak value at the center of the high-concentration zone behind the isolation baffle, rather than an average concentration. This locally high value occurs because the region behind the isolation baffle is a relatively enclosed space with very low airflow velocity, where the gas released from the adhesive accumulates rapidly. It is also consistent with the field observation that sensor abnormalities are most pronounced near the isolation area.
The above results indicate that when the support moving operation starts from the return air corner, the abnormal gas concentration at the return air corner rises sharply at the moment of support movement, which is very likely to trigger false alarms of gas sensors. Therefore, to ensure the reliable operation of the gas monitoring system and the safety of the working face, it is recommended to avoid carrying out the support moving operation preferentially from the return air corner area. This measure can not only reduce the false alarm probability of gas sensors, but also improve the accuracy of gas monitoring on the working face, thus providing a guarantee for safe production in coal mines.
Figure 13 and Figure 14 present the contour maps of abnormal gas distribution at a height of 3 m parallel to the working face floor and at different distances perpendicular to the floor in front of the isolation baffle during support moving starting from the intake air corner, under different gas emission rates.
Figure 13. Contour maps of abnormal gas distribution at 3 m height parallel to the floor during support moving at the intake air corner under different gas emission rates. (a) Abnormal gas distribution with gas emission rate of 0.016 kg/(m3·s). (b) Abnormal gas distribution with gas emission rate of 0.012 kg/(m3·s). (c) Abnormal gas distribution with gas emission rate of 0.008 kg/(m3·s). (d) Abnormal gas distribution with gas emission rate of 0.004 kg/(m3·s).
Figure 14. Contour maps of abnormal gas distribution at different distances perpendicular to the floor during support moving at the intake air corner under different gas emission rates. (a) Abnormal gas distribution at 0.1 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.016 kg/(m3·s). (b) Abnormal gas distribution at 0.1 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.012 kg/(m3·s). (c) Abnormal gas distribution at 0.1 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.008 kg/(m3·s). (d) Abnormal gas distribution at 0.1 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.004 kg/(m3·s). (e) Abnormal gas distribution at 0.4 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.004 kg/(m3·s). (f) Abnormal gas distribution at 0.7 m in front of the isolation baffle perpendicular to the floor with gas emission rate of 0.004 kg/(m3·s).
As shown in Figure 13 and Figure 14, when the support moving operation started from the intake air corner, the increase in abnormal gas concentration at the return air corner was significantly lower than that when starting from the return air corner. The core reason is that after the instantaneous emission of abnormal gas during support moving, the wind speed in the area behind the isolation baffle was high, which diluted the abnormal gas immediately. The subsequently emitted abnormal gas needed to travel a long path to diffuse to the return air corner, and was further diluted by the airflow during this process. Under different abnormal gas emission rates in the moved support area, the overall distribution of abnormal gas in the working face did not show an obvious regular change, indicating that when moving supports from the intake air corner, the abnormal gas can be fully diluted in the working face if its emission rate does not exceed a specific threshold. When the abnormal gas emission rate in the moved support area was 0.016 kg/(m3·s), the mass fraction of abnormal gas in the return air corner was lower than 0.2, which was much lower than the concentration level when moving supports from the return air corner at the same emission rate. In addition, since the hydraulic supports changed the airflow direction during support moving from the intake air corner, the abnormal gas mainly accumulated in the area close to the isolation baffle. In summary, when starting support moving from the intake air corner, the abnormal gas undergoes dual dilution effects of the high wind speed area behind the isolation baffle and the long path of the working face, and most of the gas can be effectively diluted, thus significantly reducing the false alarm risk of gas sensors.
It is worth noting that abnormal gases are heavier than air. However, high concentrations are observed near the roof rather than near the floor. This apparent contradiction can be explained by the entrainment–transport mechanism: the high-velocity airflow zone near the roof entrains gas-rich air from the source region behind the isolation baffle and transports it upward toward the return air corner. In the low-velocity zones near the return air corner, gravitational settling becomes more significant, leading to the observed high concentrations at both the roof level and the return air corner.

3.3. Distribution Characteristics of Temperature Field Under Isolation Condition

During the solidification process of the backfill, heat is released due to the hydration reaction, which causes abnormal temperature rise in the working face and the filling space, and adversely affects the occupational safety and health of underground workers. Fully considering the actual conditions of large-volume underground backfilling and the high-temperature environment in summer, this study set the wall temperatures of the backfill at 30 °C, 35 °C, and 40 °C, respectively, and set the initial airflow temperature at 25 °C, focusing on simulating the distribution law of the temperature field of the working face under different working conditions.
The simulation results show that under the filling and support moving conditions, the backfill was blocked by the isolation baffle, and the temperature field of the working face was mainly regulated by the airflow temperature, with small temperature differences in each area. Under the isolation condition, restricted by the ventilation mode, the isolation area was relatively airtight, and the wall temperature of the backfill had a more significant impact on the temperature distribution in this area. Figure 15, Figure 16 and Figure 17 show the contour maps of the temperature field at different distances from the backfill wall in the isolation area when the backfill wall temperatures are 30 °C, 35 °C, and 40 °C, respectively.
Figure 15. Temperature contour maps of the isolation area at backfill wall temperature of 30 °C. (a) Temperature distribution at 0.5 m from the backfill wall. (b) Temperature distribution at 1.5 m from the backfill wall. (c) Temperature distribution at 2.5 m from the backfill wall.
Figure 16. Temperature contour maps of the isolation area at backfill wall temperature of 35 °C. (a) Temperature distribution at 0.5 m from the backfill wall. (b) Temperature distribution at 1.5 m from the backfill wall. (c) Temperature distribution at 2.5 m from the backfill wall.
Figure 17. Temperature contour maps of the isolation area at backfill wall temperature of 40 °C. (a) Temperature distribution at 0.5 m from the backfill wall. (b) Temperature distribution at 1.5 m from the backfill wall. (c) Temperature distribution at 2.5 m from the backfill wall.
As shown in Figure 15, Figure 16 and Figure 17, the temperatures in the areas behind the No. 1–3 isolation baffles at the head and tail of the isolation area were significantly higher than those at other positions in the area. The main reason is that the wind speed in this area was lower than that in the rest of the isolation area, resulting in poor heat dissipation. From the overall distribution of the isolation area, the temperature on the return air side was obviously higher than that on the intake air side, and the temperature at the No. 1–3 isolation baffles in the head area was also higher than that in the tail area. This is because the heat dissipated from the backfill wall is transported by the airflow from the intake air side to the return air side, causing continuous heat accumulation on the return air side. When the backfill wall temperatures were set at 30 °C, 35 °C, and 40 °C, the local maximum temperatures at different distances near the wall in the isolation area were 27.19 °C, 29.68 °C, and 32.06 °C, respectively. It can be concluded that for every 5 °C decrease in the backfill wall temperature, the local maximum temperature drops by approximately 2 °C. In summary, under the isolation condition, especially during summer operations, the temperatures in the areas behind the No. 1–3 isolation baffles at the head and tail and the area close to the backfill wall are relatively high. To ensure the safety and comfort of workers, necessary cooling or enhanced ventilation measures should be taken in the above-mentioned areas.
It should be noted that the temperature field simulation in this study adopts a constant-temperature boundary at the backfill wall without coupling chemical reaction heat. This simplification is justified by our previous thermogravimetric analysis (STA-MS) results [15]: the adhesive volatile process in the 25–50 °C range is dominated by physical evaporation, with no significant exothermic or endothermic peaks observed in the DSC curve. Significant chemical reaction heat release (crosslinking and decomposition reactions) occurs only above 150 °C, which is far beyond the temperature range considered in this study (25–42 °C). Therefore, the chemical reaction heat has a negligible impact on the temperature field under the studied conditions. The dominant heat source in this study is the hydration heat from backfill material solidification, which has already been accounted for through the constant wall temperature boundary condition. For scenarios involving higher temperatures (e.g., spontaneous heating), a fully coupled thermo-chemical model should be employed.

3.4. Effects of Working Face Wind Speed on Distribution Characteristics of Abnormal Gas Concentration and Temperature Field

To investigate the influence law of working face wind speed on the distribution of abnormal gas concentration and temperature field, according to the allowable wind speed range of mine ventilation (0.25–4 m/s) specified in the Coal Mine Safety Regulations, with other parameters and boundary conditions of the numerical simulation unchanged, the abnormal gas emission rate was uniformly set to 0.004 kg/(m3·s). The influence of wind speed on the distribution of abnormal gas concentration and temperature field of the working face was analyzed by adjusting the inlet boundary wind speed.

3.4.1. Distribution of Abnormal Gas Concentration

Based on the baseline condition with a working face wind speed of 1.5 m/s, two additional wind speed conditions of 2 m/s and 2.5 m/s were set. The abnormal gas distribution maps were intercepted and analyzed at a height of 3 m parallel to the floor and at different positions perpendicular to the floor (0.1 m in front of the isolation baffle under filling and support moving conditions, 0.5 m behind the isolation baffle under isolation condition). The abnormal gas concentration distributions under different working conditions are shown in Figure 18 and Figure 19, respectively.
Figure 18. Contour maps of abnormal gas distribution at 3 m height parallel to the floor under various working conditions and different wind speeds. (a) Post-filling condition, working face wind speed of 1.5 m/s. (b) Post-filling condition, working face wind speed of 2 m/s. (c) Post-filling condition, working face wind speed of 2.5 m/s. (d) Isolation condition, working face wind speed of 1.5 m/s. (e) Isolation condition, working face wind speed of 2 m/s. (f) Isolation condition, working face wind speed of 2.5 m/s. (g) Support moving condition at intake air corner, working face wind speed of 1.5 m/s. (h) Support moving condition at intake air corner, working face wind speed of 2 m/s. (i) Support moving condition at intake air corner, working face wind speed of 2.5 m/s.
Figure 19. Contour maps of abnormal gas distribution at different distances perpendicular to the floor under various working. (a) Post-filling condition, working face wind speed of 1.5 m/s. (b) Post-filling condition, working face wind speed of 2 m/s. (c) Post-filling condition, working face wind speed of 2.5 m/s. (d) Isolation condition, working face wind speed of 1.5 m/s. (e) Isolation condition, working face wind speed of 2 m/s. (f) Isolation condition, working face wind speed of 2.5 m/s. (g) Support moving condition at intake air corner, working face wind speed of 1.5 m/s. (h) Support moving condition at intake air corner, working face wind speed of 2 m/s. (i) Support moving condition at intake air corner, working face wind speed of 2.5 m/s.
As shown in Figure 18 and Figure 19, the working face wind speed had a significant regulatory effect on the accumulation characteristics of abnormal gas under the three working conditions of filling, isolation, and support moving. Under the filling and support moving conditions, with the increase in working face wind speed, the distribution range of abnormal gas gradually narrowed, and its concentration decreased significantly, indicating that higher wind speed can effectively promote the discharge of abnormal gas and improve the overall gas environment of the working face. Under the isolation condition, although the ventilation condition of the isolation area was relatively poor, the distribution range and concentration of abnormal gas in the area also showed an obvious downward trend with the increase in wind speed, which illustrates that appropriately increasing the air volume of the working face can effectively alleviate the accumulation of abnormal gas in the isolation area.
In summary, reasonably increasing the air volume of the working face in combination with actual production conditions under various working conditions can significantly improve the abnormal gas accumulation situation. Increasing the wind speed can not only effectively reduce the concentration of abnormal gas in the isolation area, but also reduce the false alarm risk of gas sensors. Therefore, in engineering practice, optimizing the ventilation parameters of the working face (such as appropriately increasing the air supply volume of the working face) is an important technical means to alleviate the problem of abnormal gas accumulation, which is of great engineering value for ensuring safe production in coal mines.

3.4.2. Distribution of Temperature Field

In this study, the backfill wall temperature was set at 40 °C, and two working conditions with working face wind speeds of 2 m/s and 2.5 m/s were selected. After iterative convergence while keeping other parameters and boundary conditions unchanged, temperature contour maps at different distances from the backfill wall along the direction perpendicular to the floor were obtained. A comparative analysis was carried out with the 1.5 m/s wind speed condition as the baseline, to explore the influence law of wind speed on the temperature field distribution in the isolation area. The temperature field distributions in the isolation area are shown in Figure 20, Figure 21, and Figure 22, respectively.
Figure 20. Temperature field contour maps of the isolation area at 0.5 m from the backfill wall under different wind speeds. (a) Temperature field distribution of the isolation area at wind speed of 1.5 m/s. (b) Temperature field distribution of the isolation area at wind speed of 2 m/s. (c) Temperature field distribution of the isolation area at wind speed of 2.5 m/s.
Figure 21. Temperature field contour maps of the isolation area at 1.5 m from the backfill wall under different wind speeds. (a) Temperature field distribution of the isolation area at wind speed of 1.5 m/s. (b) Temperature field distribution of the isolation area at wind speed of 2 m/s. (c) Temperature field distribution of the isolation area at wind speed of 2.5 m/s.
Figure 22. Temperature field contour maps of the isolation area at 2.5 m from the backfill wall under different wind speeds. (a) Temperature field distribution of the isolation area at wind speed of 1.5 m/s. (b) Temperature field distribution of the isolation area at wind speed of 2 m/s. (c) Temperature field distribution of the isolation area at wind speed of 2.5 m/s.
As shown in Figure 20, Figure 21 and Figure 22, increasing the wind speed can effectively reduce the local temperature in the isolation area. However, restricted by the ventilation mode, the temperature in the area behind the No. 1–3 isolation baffles at the tail did not show an obvious downward trend after the wind speed increased. In contrast, the temperature in the area behind the No. 1–3 isolation baffles at the head decreased significantly with the increase in wind speed, and this phenomenon was more prominent in the area close to the backfill wall. When the wind speed increased from 1.5 m/s to 2 m/s, the local temperature behind the No. 1–3 isolation baffles at the head decreased significantly. When the wind speed further increased from 2 m/s to 2.5 m/s, the overall temperature change in the isolation area was not obvious. This indicates that appropriately increasing the wind speed can effectively reduce the local temperature in the isolation area, but limited by the ventilation mode, continuously increasing the wind speed has a limited further cooling effect on the isolation area.

3.5. Field Validation

To verify the reliability of the CFD simulation results, field gas inspection data from the No. 33 upper 32 backfill working face were collected under the three operating conditions (post-backfilling, isolation, and support advancing). Portable gas detectors were positioned at representative monitoring points, including the return air corner, behind selected hydraulic supports, and along the intake side. The measured CH4 readings represent the equivalent sensor response induced by adhesive volatile gases, rather than true methane concentrations, because the catalytic combustion-type CH4 sensors are cross-sensitive to C5H12 and C6H14 emitted during isolation and support movement [15]. The spatial distribution of the field readings is compared against the CFD-predicted high-concentration zones below.
As shown in Figure 23, the field measurements are qualitatively consistent with the CFD predictions across all three operating conditions. Under the post-backfilling condition, the CH4 equivalent reading at the return air corner reached 0.32–0.34%, whereas the intake-side monitoring point behind support #36 showed essentially zero response, matching the simulated pattern of gas accumulation at the return air corner and clean air along the intake side. Under the isolation condition, the maximum field reading of 1.00% was recorded behind support #65 inside the enclosed isolation zone, which is far higher than the 0.05–0.07% measured at the return air corner. This confirms the CFD finding that the isolated space behind the baffle acts as the dominant gas accumulation zone due to restricted ventilation. Under the support-advancing condition, the roof-side points behind supports #30 and #47 recorded 0.44% and 0.39%, respectively, while the floor-side point behind support #58 remained at 0%, in good agreement with the simulated roof-directed transport of the instantaneous gas release.
Figure 23. Comparison of field-measured CH4 equivalent readings and CFD-predicted C5H12 mass fractions.

4. Conclusions

In this paper, the numerical simulation method was adopted to systematically analyze the distribution laws of the airflow field, abnormal gas concentration, and temperature field of the working face under different working conditions. The regulatory effect of wind speed on the distribution of abnormal gas and the temperature field of the working face was investigated by adjusting the working face wind speed. The main conclusions are as follows:
(1)
Under all working conditions, abnormal gas presents a high-concentration accumulation characteristic in low wind speed areas, including the return air corner of each working condition and the isolation area under the isolation condition. Under the filling and isolation conditions, abnormal gas mainly accumulates in the area in front of the isolation baffle near the return air side. Under the simulated conditions of this study, starting support moving from the return air corner leads to a more significant increase in abnormal gas concentration at the return air corner, while starting support moving from the intake air corner can effectively dilute the abnormal gas and result in a more uniform concentration distribution.
(2)
Under the isolation condition, the isolation area has strong airtightness and low overall wind speed, and the backfill temperature has a significant impact on the temperature distribution in this area. In the isolation area, the temperatures behind the No. 1–3 isolation baffles at the head and tail are significantly higher than those in other areas. The overall distribution shows that the temperature on the return air side is higher than that on the intake air side, and the temperature near the isolation baffle in the head area is higher than that in the tail area.
(3)
Under the filling and support moving conditions, with the increase in working face wind speed, the concentration of abnormal gas in the working face decreases significantly, and the accumulation range of abnormal gas also narrows obviously. Under the isolation condition, when the wind speed increases from 1.5 m/s to 2 m/s, the local high-temperature range in the isolation area is significantly reduced. However, when the wind speed is further increased to 2.5 m/s, the reduction amplitude of the local high-temperature area is not obvious, and the further cooling effect of continuously increasing wind speed is limited.

Author Contributions

Conceptualization, X.G., D.Y. and H.Z.; Methodology, D.Y., X.L. and H.Z.; Software, W.P., X.L. and H.T.; Validation, D.Y.; Formal analysis, R.L.; Investigation, W.P.; Resources, X.G.; Data curation, W.P.; Writing—original draft, X.G.; Writing—review & editing, X.L.; Visualization, R.L. and H.T.; Supervision, H.Z.; Project administration, D.Y.; Funding acquisition, X.G. and H.Z. All authors have read and agreed to the published version of the manuscript.

Funding

This project was financially supported by the State Key Laboratory of Safe Mining of Deep Coal and Environmental Protection (Grant No. 2025QN12103).

Data Availability Statement

Due to privacy, legal, and ethical considerations, the data presented in this study are not publicly available and can be obtained from the corresponding author upon reasonable request.

Conflicts of Interest

Authors Xinyu Ge and Dingyi Yu are affiliated with China Coal Xinji Energy Co., Ltd. Author Xiao Liu is affiliated with CCTEG Shenyang Research Institute Co., Ltd. Author Rui Luo is affiliated with Huainan Mining Group Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  1. Bai, E.H.; Wang, R.L.; Guo, W.B.; Tan, Y.; Lei, W.; Li, H.; Wei, Z. Green coal mining technology of overburden grout injection with directional drilling under buildings. Bull. Eng. Geol. Environ. 2025, 84, 391. [Google Scholar] [CrossRef] [Scilit]
  2. Zhang, Q.; Wang, Z.J.; Zhang, J.X.; Jiang, H.; Wang, Y.; Yang, K.; Tian, X.; Yuan, L. Integrated green mining technology of “coal mining-gangue washing-backfilling-strata control-system monitoring”—Taking Tangshan Mine as a case study. Environ. Sci. Pollut. Res. 2022, 29, 5798–5811. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Guo, P.H.; Wang, X.Q.; Meng, X.R. Evolutionary game study and empirical analysis of the adoption of green coal mining technology: A case study of ITMDB. Energy 2024, 313, 134019. [Google Scholar] [CrossRef] [Scilit]
  4. Zhang, J.Y.; Lyu, C.; Luo, Y.C.; Yao, S.; Yao, X.; Huang, L.; Liu, K.; Hou, K. Research status and prospect of resource utilization of coal gangue. Ind. Miner. Process. 2024, 53, 40–49. [Google Scholar] [CrossRef]
  5. Deng, Y.S.; Dong, C.H.; Wu, A.L.; Zhuang, Z.; Chen, Z. Current situation of comprehensive treatment of coal gangue piles and exploration of zero-carbon treatment in China. Saf. Coal Mines 2024, 55, 120–128. [Google Scholar] [CrossRef]
  6. Zheng, J.H.; Zhou, X.X.; Li, W.J.; Sang, Y.; Ma, Z.; Guo, Y.; Cheng, F. Effects of solid waste dosages on the comprehensive properties of coal gangue-fly ash paste backfilling materials. Constr. Build. Mater. 2026, 514, 145524. [Google Scholar] [CrossRef] [Scilit]
  7. An, H. Application of Slag Cementitious Materials and Admixtures in Coal Mine Paste Backfilling. Master’s Thesis, China University of Mining and Technology, Xuzhou, China, 2021. [Google Scholar] [CrossRef]
  8. Zhang, X.G.; Bai, J.W.; Wang, H.; Jiang, N. Study on Proportioning Test of Coal Solid Waste Paste Filling Material. In 1st International Conference on Energy and Environmental Protection (ICEEP 2012), Hohhot, China, 23–24 June 2012; Trans Tech Publications Ltd.: Pfaffikon, Switzerland, 2012; pp. 1086–1090. [Google Scholar] [CrossRef] [Scilit]
  9. Hao, L.L.; Qin, S.J.; Pang, W.; Li, S.; Lyu, D.; Zhang, X.; Hou, J.; Men, C. Research progress on migration law of harmful elements and environmental risk assessment during fly ash storage and utilization. Bull. Chin. Ceram. Soc. 2025, 44, 151–168. [Google Scholar]
  10. Zhou, K.; Sun, X.X.; Ma, H.Y.; Liu, S.; Wei, L.; Zhong, X. Gas production test of filling slurry and its influence on CO sensor monitoring. China Saf. Sci. J. 2023, 33, 176–182. [Google Scholar] [CrossRef]
  11. Liang, Y.T.; Tian, F.C.; Feng, W.B.; Shao, Z.; Meng, X.; Chen, C. Research progress of coal mine gas detection technology. J. China Coal Soc. 2021, 46, 1701–1714. [Google Scholar]
  12. Tan, B.; Shao, Z.Z.; Guo, Y.; Zhao, T.; Zhu, H.; Li, C. Research on grading early warning of coal spontaneous combustion based on correlation analysis of index gas. China Saf. Sci. J. 2021, 31, 33–39. [Google Scholar]
  13. Guo, J.; Liu, H.; Jin, Y.; Cai, G.; Liu, Y.; Yang, P. Review of detection methods for hidden fire sources of underground coal spontaneous combustion and prospect of new technologies. China Saf. Sci. J. 2022, 32, 111–119. [Google Scholar] [CrossRef]
  14. Zhang, J.Q.; Yang, K.; He, X.; Zhao, X.; Wei, Z.; He, X. Research status of comprehensive utilization of coal-based solid waste (CSW) and key technologies of filling mining in China: A review. Sci. Total Environ. 2024, 926, 171855. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Lu, W.; Luo, R.; Zhang, Q.S.; Zhuo, H.; Li, J.; Zhu, S. Study on cross-interference effect of abnormal gas on sensors in backfill working face. China Saf. Sci. J. 2025, 35, 40–48. [Google Scholar]
  16. Ma, H.Y. Study on Gas Generation Law of Coal Mine Paste Filling Material and Correction of False Alarm of Electrochemical CO Sensor. Master’s Thesis, China University of Mining and Technology, Xuzhou, China, 2025. [Google Scholar]
  17. Zheng, Q.W.; Zhou, Y.; Liu, X.; Liu, M.; Liao, L.; Lv, G. Environmental hazards and comprehensive utilization of solid waste coal gangue. Prog. Nat. Sci. Mater. Int. 2024, 34, 223–239. [Google Scholar] [CrossRef]
  18. Wang, C.Q.; Wang, Z.Y.; Huang, D.M.; Huang, Q.C.; Chen, Y.; Zhang, H.; Shui, Z.H. Recovery and recycling core of phosphogypsum: Characteristic hazardous elements risk assessment and analysis. Process Saf. Environ. Prot. 2023, 170, 738–756. [Google Scholar] [CrossRef] [Scilit]
  19. Torres-Sanchez, R.; Sanchez-Rodas, D.; Sanchez de la Campa, A.M.; de La Rosa, J.D. Hydrogen fluoride concentrations in ambient air of an urban area based on the emissions of a major phosphogypsum deposit (SW, Europe). Sci. Total Environ. 2020, 714, 136891. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Xie, H.P.; Gao, F.; Jv, Y. Research and exploration of deep rock mass mechanics. Chin. J. Rock Mech. Eng. 2015, 34, 2161–2178. [Google Scholar]
  21. Chen, Q.S.; Zhang, Q.L.; Fourie, A.; Xin, C. Utilization of phosphogypsum and phosphate tailings for cemented paste backfill. J. Environ. Manag. 2017, 201, 19–27. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Hu, Z.Q.; Zhao, Y.L.; Mao, Z. Principles and key technologies of large-scale ecological utilization of coal gangue. J. China Coal Soc. 2024, 49, 978–987. [Google Scholar]
  23. Ko, J.H.; Xu, Q.Y.; Jang, Y.-C. Emissions and control of hydrogen sulfide at landfills: A review. Crit. Rev. Environ. Sci. Technol. 2015, 45, 2043–2083. [Google Scholar] [CrossRef] [Scilit]
  24. Zhuo, H. Study on Fracture air Leakage and Coal Spontaneous Combustion Law in Shallow Buried Contiguous Coal Seam Groups. Master’s Thesis, China University of Mining and Technology, Xuzhou, China, 2021. [Google Scholar] [CrossRef]
  25. Qin, Y.P.; Liu, W.; Yang, X.L.; Luo, W.; Hao, Y. Numerical simulation of spontaneous combustion in goaf based on non-Darcy seepage. J. China Coal Soc. 2012, 37, 1177–1183. [Google Scholar] [CrossRef]
  26. Shi, G.Q.; Hu, G.F.; Wang, D.M.; Wang, S. Four-dimensional dynamic simulation of distribution law of spontaneous combustion “three zones” in goaf. J. China Univ. Min. Technol. 2014, 43, 189–194. [Google Scholar] [CrossRef]
  27. Hao, Y.; Pang, J.L. Distribution law of spontaneous combustion “three zones” in goaf under different air volumes and gas conditions. Min. Saf. Environ. Prot. 2020, 47, 40–44. [Google Scholar] [CrossRef]
  28. Xu, C.F.; Zheng, Z.Y.; Yuan, S.S.; Yao, H.F.; Wu, H.J. Study on distribution of spontaneous combustion three zones in goaf of long fully-mechanized caving face in shallow buried coal seam. Coal Eng. 2014, 46, 76–78. [Google Scholar] [CrossRef]
  29. Shao, G.A.; Zou, Y.M. Prevention and control technology of residual coal spontaneous combustion in goaf under large-diameter borehole drainage. Saf. Coal Mines 2020, 51, 74–77, 82. [Google Scholar]
  30. Lu, W.; Cao, Y.-J.; Tien, J.C. Method for prevention and control of spontaneous combustion of coal seam and its application in mining field. Int. J. Min. Sci. Technol. 2017, 27, 839–846. [Google Scholar] [CrossRef] [Scilit]
  31. Zhang, J.; Zhang, H.T.; Ren, T.; Wei, J.; Liang, Y. Proactive inertisation in longwall goaf for coal spontaneous combustion control—A CFD approach. Saf. Sci. 2019, 113, 445–460. [Google Scholar] [CrossRef] [Scilit]
  32. Zhang, J.L.; Ruan, G.Y.; Bai, Y.; Ning, T. Mathematical model and numerical simulation study of the mining area with multiple air leakage paths. Mathematics 2022, 10, 2484. [Google Scholar] [CrossRef] [Scilit]
  33. Yue, N.F.; Jin, Y.; Chen, G.L.; Sun, M.; Ran, X. Study on division method of coal spontaneous combustion dangerous zone in goaf based on multi-parameters. Min. Saf. Environ. Prot. 2021, 48, 1–5+11. [Google Scholar] [CrossRef]
  34. Chai, J.M. Investigation of spontaneous combustion zones and index gas prediction system in goaf of “Isolated Island” working face. Fire 2022, 5, 67. [Google Scholar] [CrossRef] [Scilit]
  35. Zheng, L.Y.; Tian, Z.H.; Zhu, H.J.; Lian, P.; Fan, C.; Yang, Z. Study on three-dimensional distribution characteristics of coal spontaneous combustion dangerous zone in goaf of shallow buried extra-thick coal seam. Coal Eng. 2023, 55, 79–84. [Google Scholar] [CrossRef]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.