Parametric Study of Sinusoidal Rib Turbulators for Heat Transfer Enhancement in Turbine Blade Internal Cooling Channels

,
,
and
1
Hainan Institute, Zhejiang University, Sanya 572000, China
2
School of Mechanics and Electrical Engineering, Hubei Polytechnic University, Huangshi 435003, China
3
School of Power and Energy, Nanchang Hangkong University, Nanchang 330063, China
*
Author to whom correspondence should be addressed.
This article belongs to the Section Chemical Processes and Systems

Abstract

Higher turbine inlet temperatures improve cycle efficiency but intensify blade thermal loading, so internal passages rely on turbulators that raise convection within coolant pressure budgets. Streamwise sinusoidal ribs introduce curvature and spanwise phasing beyond straight transverse bars, yet reconciled multi-row thermal–hydraulic data for such layouts in high-aspect-ratio blade-cooling analogues remain scarce. Steady three-dimensional computational fluid dynamics (CFD) of turbulent airflow in a 4:1 rectangular channel with uniform heat flux on one ribbed wall are applied to compare nine parametric sinusoidal-rib layouts and one transverse baseline at bulk Reynolds numbers from 20,000 to 90,000. The normalized Nusselt number ( N u / N u 0 ), Fanning friction factor ( f / f 0 ), and composite thermal–hydraulic performance indices quantify the trade-off. Several layouts outperform the transverse baseline; a streamwise-increasing rib-height schedule achieves the highest pressure-drop-weighted index, whereas a large-amplitude uniform waviness gives the best heat-transfer-dominated index. The parametric matrix indicates when streamwise waviness merits further study in ribbed passage design.

1. Introduction

Aviation gas turbines rely on increasingly high turbine inlet temperatures to improve efficiency and thrust, but increased thermal loading threatens blade life without adequate cooling [1,2,3,4,5]. External film cooling and thermal barrier coatings limit hot-gas exposure at the airfoil surface [1,6,7,8,9,10,11,12], while internal ribbed, dimpled, pin-fin, and impingement passages augment wall-side convection [13,14,15,16,17,18,19]. Serpentine coolant routes preserve the external aerodynamic profile while increasing heat removal along the flow path [20]. Because coolant mass flow and pumping power are strictly limited, designers must raise heat transfer without a disproportionate rise in passage pressure loss. Periodic ribs remain a primary means to that end: they trip the near-wall boundary layer, promote separation and reattachment, and drive secondary motion that advects cooler core fluid toward the heated wall—behavior well established in square and near-square channels by experiment and three-dimensional computational fluid dynamics (CFD) [21,22,23].
Among turbulator families, angled and V-shaped ribs have received the most systematic attention in turbine internal cooling [16,19,20,24,25,26,27,28,29,30,31]. For 45– 60 ∘ layouts, experiments and Han-type correlations report large gains in area-averaged Nusselt number ( N u ), together with higher Fanning friction factor (f). The thermal–hydraulic balance is commonly summarized by N u / N u 0 , f / f 0 , and composite performance indices, with pitch, rotation number ( R o ), and blockage ratio strongly influencing both metrics [20,21,24,25,31]. In high-aspect-ratio ducts ( W / H = 2 –4) representative of blade internal passages, straight transverse ribs provide baseline N u / N u 0 – f / f 0 maps at high Reynolds number and clarify the aspect-ratio and inlet effects that are widely used to benchmark new concepts [13,15,20,32,33,34,35,36]. These studies form a strong reference framework for conventional rib geometries, while offering limited row-resolved guidance on discrete streamwise waviness.
More elaborate layouts attempt to move beyond that baseline. Hybrid geometries—ribs combined with dimples, grooves, truncated roots, or wavy–angled combinations—can raise N u / N u 0 further, although often at higher f / f 0 and with greater manufacturing complexity [14,37,38,39,40,41,42,43,44,45,46]. In square channels, continuous wavy walls and wavy ribs frequently deliver N u / N u 0 on the order of 1.5 – 2.5 and f / f 0 on the order of 3–6, with a more uniform wall-temperature pattern than straight transverse bars. However, such geometries differ from discrete multi-row rib arrays [47,48,49,50]. Discrete sinusoidal ribs introduce flexibility in streamwise amplitude, spanwise period count, and rib height, and prior work shows that each can strongly affect heat transfer and pressure loss [51,52]. Optimization studies further reveal that orientation, pitch, and waviness interact nonlinearly with Reynolds number and passage aspect ratio [30,53].
Parallel efforts have pursued greater engine realism. Rib cooling has been extended to rotating ducts with buoyancy effects [2,4,19,21,54], as well as to multi-layer passages, inserted plates, pin-fin composites, and serpentine blade schemes [18,55,56,57,58,59,60,61,62,63,64,65]. Reynolds-averaged Navier–Stokes (RANS) and large-eddy simulation (LES) studies have also clarified how conjugate effects, detached ribs, and turbulence-model choice can shift rib rankings [22,23,66,67,68,69,70,71,72,73,74,75,76]. Because rotation and buoyancy can reorder N u and f relative to stationary ducts, and blade-resolved layouts remain geometry-specific, these studies do not readily yield a controlled, row-resolved sinusoidal matrix on a common normalization basis. Nevertheless, idealized stationary channels retain the separation–reattachment physics governing local heat transfer, making them a consistent platform for isolating waviness and row-wise height effects before rotation, conjugate walls, and multi-pass coupling enter full-engine analyses.
For W / H = 4 blade-cooling analogues, prior studies of streamwise sinusoidal ribs have demonstrated sensitivity to wave amplitude, spanwise period, and rib height [51,57,58]. However, direct comparison among multi-row layouts remains difficult because many reports concern continuous wavy passages, vary only one geometric parameter, or present N u / N u 0 , f / f 0 , and composite indices under different numerical and thermal settings. Streamwise waviness can shorten separation regions and redistribute high- N u zones relative to straight transverse ribs, while row-wise height schedules offer an additional means to balance blockage and mixing along the coolant path. Designers therefore need row-resolved, side-by-side metrics to select promising combinations before costly experiments or engine-resolved modeling. Accordingly, this work compares discrete five-row sinusoidal ribs on a common footing: nine parametric layouts and a transverse baseline (Table 1) in a 4:1 rectangular channel, with streamwise amplitude, spanwise period count, and row-wise rib-height schedules varied as separate design groups under matched boundary conditions and smooth-channel references. Steady three-dimensional CFD with a shear-stress transport (SST) k– ω turbulence model is applied at bulk Reynolds numbers from 20,000 to 90,000 , reporting N u / N u 0 , f / f 0 , composite performance indices, and supporting local temperature, Nusselt-number, and flow-field results. The goal is to rank the candidate layouts on a uniform normalization basis and to identify geometries that improve wall-side heat removal relative to the transverse baseline while keeping the associated pressure penalty within acceptable limits for turbine internal cooling.
Table 1. Geometric parameters of sinusoidal and transverse rib cases (unit: mm). Columns are grouped by rib row 1–5. For row i, ( a i 1 , b i 1 ) and ( a i 2 , b i 2 ) are the left and right boundary streamwise positions, respectively; in Equation (1), k i is the number of spanwise periods in that row ( k i = 0 for transverse TR-A) and e i is rib height. Identical pairs ( a i 1 , b i 1 ) = ( a i 2 , b i 2 ) indicate a straight rib segment in the spanwise projection for that row.
The remainder of this paper is organized as follows. Section 2 describes the computational domain, rib geometries, governing equations, numerical setup, data-reduction definitions, and mesh-independence verification. Section 3 presents numerical validation, normalized heat-transfer and friction results, flow structures, and overall thermal–hydraulic performance. Section 4 summarizes the principal findings and discusses limitations.

2. Methodology

2.1. Computational Domain

Turbulent flow and convection in a rectangular channel are modeled with three-dimensional, steady CFD as a blade internal-cooling analogue. This idealization is standard in experimental and numerical rib-channel work [22,23,47,58,71].
This work is numerical; no laboratory experiments are included. The bulk Reynolds number R e = ρ V in D h / μ varies from 20,000 to 90,000 based on the channel hydraulic diameter D h = 128 mm and inlet velocity. This band represents turbulent ribbed-channel investigations frequently reported for large-scale models of blade passages (often 10 4 – 10 5 , depending on facility size and coolant density) [20,24,25,35] and avoids the cost of fully resolving the highest- R e engine-relevant conditions in steady CFD. A single-engine operating line is not recovered without specifying a target blade coolant channel D h , mass flow, and thermophysical state; Section 2.4 lists dimensionless groups and geometric ratios for rescaling results to other designs.
Figure 1a sketches a rectangular duct of height H = 80 mm and width W = 320 mm, giving hydraulic diameter D h = 128 mm and aspect ratio W / H = 4 . This falls in the range from the nearly square to high-aspect passages that are commonly used to mimic blade internal cooling passages in experiments and CFD [20,32]. The computational domain comprises three streamwise segments: entrance, ribbed test, and outlet. The inlet run L 1 = 500 mm (≈3.9 D h ) follows widespread rib-channel practice [22,34]. For turbulent flow, a hydrodynamic entrance length scaling as L fd / D h ∼ R e 1 / 6 implies L fd ≈ 20 – 30 D h at R e = 20,000 – 90,000 , so the chosen L 1 deliberately under-resolves full development to control cost. Truncating the approach to L 1 ≈   3.9 D h rather than 20– 30   D h can bias absolute N u and f on the order of 5– 15 % relative to a fully developed prescription, with relative ordering among ribs largely unchanged under identical inlet data [33,34,77]. The bulk state entering the ribs may therefore retain development transients; configuration ranking should remain stable because all layouts share the same inlet. The ribbed test segment has length L 2 = 700 mm, with transverse or sinusoidal ribs of pitch P and height e on the bottom wall (Figure 1b). A downstream outlet run of L 3 = 300 mm limits exit recirculation artifacts.
Figure 1. Schematic diagrams of (a) the computational domain (entrance, test, and exit lengths L 1 , L 2 , L 3 ) for cooling channels with transverse or sinusoidal ribs, and (b) transverse and sinusoidal rib schemes (pitch P, height e, streamwise x, spanwise y). The bottom wall of the test section receives uniform heat flux; all other walls are adiabatic. Labels indicate L 1 – L 3 , P, e, and coordinate directions; the inset illustrates Equation (1) parameters ( a i j , b i j , k i ) for one rib row.
The ribs are placed on the bottom surface of the test section, with a right-handed Cartesian coordinate system in which x is the streamwise direction (main flow direction), y is the spanwise direction (channel width), and z is the wall-normal direction (channel height). Streamwise sinusoidal rib edges follow parameterizations used in prior wavy-wall and sinusoidal-rib studies [47,51]. The rib boundaries are expressed as
x i j = a i j + b i j sin 2 π k i y W ,
where aij is the streamwise (x) position of the j-th boundary of the i-th sinusoidal rib, bij is the amplitude (also in the x-direction), ki is the number of full sinusoidal periods across the channel span (spanwise coordinate y from 0 to the channel width W; k i = 0 recovers straight rib edges), and y is the spanwise coordinate. Here, i = 1–5 denotes the rib row number, and j = 1, 2 corresponds to the left and right boundaries, respectively. All rib configurations in Table 1 are illustrated in Figure 2 (plan view); for cases SR-G, SR-H, and SR-I, the rib height e varies across rows and is not distinguished in this bottom view. Nine configurations (SR-A through SR-I) are selected to systematically sample the parameter space: SR-A, SR-B, and SR-C vary amplitude b (10, 30, 50 mm) at constant spanwise period count k = 2 (Equation (1)); SR-D, SR-E, and SR-F combine row-wise amplitude and k variations to explore intermediate configurations; and SR-G, SR-H, and SR-I vary rib height e across rows (symmetric, decreasing, and increasing profiles). This sampling strategy covers the range of geometric parameters reported in prior wavy/sinusoidal rib studies [47,51] and isolates the effect of each parameter group. Table 1 lists the geometric parameters for each configuration.
Figure 2. Bottom view schematics of all rib configurations in Table 1 (TR-A and SR-A–SR-I).

2.2. Rationale for Rib-Height Schedules

Cases SR-G, SR-H, and SR-I isolate row-wise variation in rib height e, a design motif distinct from uniform-height arrays. Table 1 defines SR-G as a symmetric profile (10–8–6–8–10 mm) with a mid-channel minimum, SR-H as a streamwise-decreasing profile (10–8–6–4–2 mm), and SR-I as a streamwise-increasing profile (2–4–6–8–10 mm). The flow response differs accordingly: SR-H relaxes the blockage downstream and lets the boundary layer recover; SR-I ramps blockage and promotes mixing in the developing region; SR-G imposes a symmetric disturbance that balances heat transfer and friction. These three schedules complement the amplitude- and wave-number-focused cases SR-A–SR-F by testing whether monotonic or symmetric height modulation can decouple thermal gain from friction penalty. Section 3 interprets the mechanisms and performance outcomes.

2.3. Governing Equations and Numerical Setup

Three-dimensional, steady CFD with the SST k– ω closure is used to compute turbulent flow and convection in the ribbed passage [23,70,72,78]. Under steady, incompressible cold-air assumptions with negligible radiation and buoyancy [20,47], the solved system consists of continuity, momentum, and thermal energy equations coupled to the SST model (which supplies the eddy viscosity ν t ). In conservative flux form,
∂ U i ∂ x i = 0 ,
∂ ∂ x j U i U j = − 1 ρ ∂ P ∂ x i + ∂ ∂ x j ν + ν t ∂ U i ∂ x j + ∂ U j ∂ x i ,
∂ ∂ x j U j T = ∂ ∂ x j ν P r + ν t P r t ∂ T ∂ x j ,
where U i is the mean velocity, P the mean pressure, T the mean static temperature, ρ the constant density, ν = μ / ρ the kinematic viscosity, P r = 0.71 the laminar Prandtl number for air at 300 K (Table 2), and P r t = 0.85 the turbulent Prandtl number assigned in the Ansys Fluent 2022 R2 energy equation (the solver default for air and consistent with prior rib-channel SST studies [23,70]). The auxiliary k and ω transport equations follow Menter’s SST formulation [78] and are solved together with Equations (2a)–(2c) in ANSYS Fluent 2022 R2. Negligible density variation is expected because passage Mach numbers remain below 0.3 and the bulk temperature rise is modest ( Δ T / T in < 0.1 ) [20,23].
Table 2. Dimensionless groups used herein and relation to engine-oriented rotating-channel literature (where applicable). P / e and e / H refer to uniform-height cases (e.g., TR-A, SR-A–SR-F with e = 10 mm).
A uniform heat flux q = 1000 W m−2 is imposed on the bottom wall of the test section only (Figure 1); all other walls are adiabatic with no-slip conditions. This one-sided heating convention is widely adopted in ribbed-channel studies [47,51] and isolates rib-geometry effects. Real blade passages experience non-uniform external heating; the present results are therefore most applicable to comparative screening under idealized conditions. The inlet is a velocity inlet with flow normal to the inlet plane; the outlet is a pressure outlet. The inlet velocity follows the target bulk Reynolds number, R e = ρ V in D h / μ , with ρ , μ , and V in evaluated for cold air at the inlet temperature.
The domain is discretized using predominantly hexahedral grids built in ANSYS Mesh 2022 R2, with prismatic inflation on the heated wall and rib faces, near-wall growth ratios of ≈1.1– 1.2 , and streamwise/spanwise clustering in rib wakes. For SST k– ω , near-wall cells on the heated wall and rib surfaces satisfy y + < 1 on the adopted mesh (maximum y + ≈ 4 on rib crests at the highest R e ), with first-layer thickness at the flat bottom wall of order Δ y 1 ≈ 2.4 × 10 − 5 m. Convergence criteria are 10 − 5 for energy and 10 − 8 for momentum; pressure and velocity are coupled with SIMPLEC and second-order upwind discretization. Grid-refinement results for N u / N u 0 and f / f 0 are reported in Section 2.5 after the post-processing definitions. Prior rib-channel studies report 5–15% N u differences among eddy-viscosity models with similar relative ranking [28,66,70].

2.4. Data Reduction

Area-averaged and local N u , the Fanning friction factor, the smooth-wall references, the composite indices O P T 1 and O P T 2 , and the Stanton number and heat-transfer coefficient used alongside N u in Section 3 are defined below.
The convective heat transfer performance is evaluated by the area-averaged Nusselt number Nu, defined as
N u = ∫ ∫ A N u l d A l ∫ ∫ A d A l ,
where Al is the heat transfer area of the heated bottom wall. The local Nusselt number Nul on the heated bottom wall is defined as
N u l = h D h λ ,
where λ is the thermal conductivity of the cooling air. The local heat transfer coefficient h between the cooling air and the heated bottom wall is
h = q T l − T f ,
where Tl and Tf are the local wall temperature and the reference bulk temperature, respectively. Here, T f denotes a single bulk reference temperature—the arithmetic mean of area-averaged inlet and outlet temperatures in the test section. This definition is commonly used in ribbed-channel studies with uniform heat flux [27,47] and provides a single bulk temperature for the entire test section. At high Re, the bulk temperature rise is small ( Δ T bulk / T in < 0.05 ); the difference from a local bulk temperature is negligible for area-averaged Nu. At lower Re, the temperature rise is larger, but the mean inlet–outlet definition remains consistent across all configurations and does not affect the relative ranking. The flow loss in the test section is evaluated using the Fanning friction factor f, defined as
f = Δ p D h 2 ρ V i n 2 L f ,
where Δ p is the pressure drop between the inlet and outlet of the test section, and Lf is approximated by the test section length L2. The pressure drop Δ p is extracted from monitoring planes at the test section inlet and outlet only; contributions from the entrance and exit sections are excluded. The approximation L f ≈ L 2 neglects the streamwise variation of the ribbed flow path length; for sinusoidal ribs with small amplitude-to-pitch ratio, this introduces an uncertainty of less than 2% in f. The flow and heat transfer characteristics (Nu and f) are normalized by the smooth-channel values Nu0 and f0 to obtain the overall performance factors [22,27,41,79,80]:
O P T 1 = N u / N u 0 f / f 0 ,
O P T 2 = N u / N u 0 ( f / f 0 ) 1 / 3 .
The smooth-channel baseline values Nu0 and f0 are obtained from the Dittus–Boelter and Blasius correlations, respectively, [15,20,51,69]:
N u 0 = 0.023 R e 0.8 P r 0.4 ,
f 0 = 0.079 R e − 0.25 ,
where the Prandtl number is Pr = 0.71 at the inlet temperature Tin = 300 K.
The local heat transfer coefficient h from Equation (5) and its area average h ¯ = ∫ ∫ h d A / ∫ ∫ d A describe the dimensional convective resistance under the prescribed uniform heat flux. For comparison with correlations and boundary-layer practice, the Stanton number based on the inlet bulk velocity and fluid properties is
S t l = h ρ c p V in = N u l R e P r ,
with area-averaged S t ¯ = N u ¯ / ( R e P r ) . A smooth-wall reference uses S t 0 = N u 0 / ( R e P r ) from Equation (9), yielding S t / S t 0 = N u / N u 0 for fixed R e and P r . Therefore, the corresponding h ¯ ( R e ) and S t ¯ ( R e ) trends follow the same ranking; their explicit inclusion improves dimensional and dimensionless completeness without changing the comparative conclusions.

Dimensionless Groups and Turbine-Relevant Scaling

Table 2 summarizes the dimensionless quantities reported in this work and their role in turbine-passage scaling. The bulk Reynolds number R e = ρ V in D h / μ , Prandtl number P r , and Fanning friction factor f follow standard pipe/channel definitions (Equations (6)–(10)). Thermal augmentation is expressed via N u / N u 0 , f / f 0 , and the composite indices O P T 1 and O P T 2 (Equations (7) and (8)). Geometric non-dimensional parameters include the passage aspect ratio W / H = 4 , rib blockage e / H (e.g., 0.125 for e = 10 mm), and pitch-to-height ratio P / e = 10 for the uniform-height cases. In rotating turbine cooling experiments, rotation number R o = Ω D h / V in and buoyancy-related groups ( G r / R e 2 or density-ratio formulations) are commonly quoted [2,32]; in the present stationary Cartesian model, these rotation-induced mechanisms are absent ( R o ≡ 0 , no Coriolis or centrifugal source terms), and the results must be interpreted as an idealized serpentine-passage analogue rather than a rotating rig. Extension to R o > 0 and uneven wall heating is revisited in Section 4.

2.5. Mesh Independence

Four grid levels (2.8, 4.3, 6.7, and 7.3 million cells) are tested on the transverse baseline (TR-A) using the N u / N u 0 and f / f 0 definitions in Section 2.4. Relative deviations between the 4.3 and 7.3 million-cell meshes remain below 2% [81]; the 4.3 million-cell mesh is adopted for all cases. Figure 3 shows representative grid distributions and panel (d) summarizes the grid-independence check.
Figure 3. Grid distribution at (a) the inlet, (b) the transverse rib region, and (c) the sinusoidal rib region. Panels (b,c) combine a wall-parallel view with a spanwise–wall-normal (y–z) slice through the rib crest to show wake-region clustering and mesh orthogonality near the critical rib wake; (d) grid-independence validation for TR-A using N u / N u 0 and f / f 0 .

3. Results and Discussion

3.1. Numerical Validation

Due to the lack of wind tunnel data for the specific sinusoidal rib geometries investigated in this study, direct experimental comparisons are not available. Liu et al. [36] report liquid-crystal thermography and companion CFD for perforated transverse ribs with inclined holes in a rectangular duct; those geometries differ from the solid sinusoidal ribs considered here and are cited only as a qualitative benchmark. The numerical process is supported by (i) Table 3, which compares smooth-wall SST k- ω results (ribs removed, otherwise the same setup as in Section 2.3) with the Dittus–Boelter and Blasius targets in Equations (9) and (10); percentage deviations ε N u = | N u 0 − N u sim | / N u 0 and ε f = | f 0 − f sim | / f 0 are reported explicitly in Table 3. At R e = 90,000 , ε N u = 1.0 % and ε f = 0.2 % , confirming that the solver reproduces smooth-duct correlations before rib-augmented cases are interpreted. These deviations are within bands commonly reported between rib-channel CFD and correlation predictions [23,67]. (ii) The grid sensitivity study in Figure 3d applies the same near-wall refinement and curvature treatment to the sinusoidal geometries.
Table 3. Smooth duct comparison at Pr = 0.71 : correlation baselines from Equations (9) and (10) versus smooth-wall SST k- ω ( N u sim , f sim ; ribs removed from the test segment). Percentage deviations ε N u and ε f as defined in the text.

3.2. Heat Transfer Enhancement

Figure 4 ranks area-mean N u / N u 0 across all cases. The increase with streamwise amplitude (SR-A→SR-B→SR-C) reflects stronger trip-and-mixing action as curvature lengthens reattachment paths. Row-modulated layouts (SR-D–SR-F) exceed uniform low-amplitude cases when spanwise wave number and amplitude vary by row. Height-scheduled cases (SR-G–SR-I) respond according to the row-wise e profile in Table 1: SR-I limits upstream blockage, whereas SR-G and SR-H redistribute mixing along the passage. Temperature and Nusselt number distributions on the heated surface are analyzed to assess heat transfer in the sinusoidal ribbed channels [82]. Because S t / S t 0 = N u / N u 0 at fixed R e and P r (Equation (11)), every statement about normalized N u applies identically to normalized S t ; area-mean h ¯ scales linearly with N u ¯ via h ¯ = N u ¯ λ / D h , so rankings of cases for thermal augmentation are preserved across N u , h, and S t .
Figure 4. Normalized Nusselt numbers ( N u / N u 0 ) over Re = 20,000–90,000 for all ribbed channel cases.
At Re = 80,000, Figure 5 and Figure 6 show the temperature and local N u contours on the heated surface for all ribbed channel cases (TR-A and SR-A–SR-I). Row-modulated layouts (SR-D–SR-F) exceed uniform low-amplitude cases when spanwise wave number and amplitude vary by row, consistent with the stronger inter-rib stirring seen at R e = 80,000 in Figure 5 and Figure 6. Equation (4) implies that local N u is inversely related to local wall temperature under constant thermophysical properties and an approximately constant reference temperature, so local performance follows from the temperature and N u distributions: high wall temperatures and low Nusselt numbers indicate poor heat transfer. The elevated N u l band immediately upstream of the first rib near the inlet arises from a thin approaching thermal boundary layer on the uniformly heated floor, which produces steep wall-normal temperature gradients consistent with Equations (4) and (5).
Figure 5. Temperature contours on the heated surface of the test section for all ribbed channel cases at Re = 80,000. The mainstream direction is from left to right.
Figure 6. Local Nu contours on the heated surface of the test section for all ribbed channel cases at Re = 80,000. The mainstream direction is from left to right.
Figure 7 and Figure 8 extend the TR-A versus SR-B comparison across R e = 20,000 – 90,000 . A high-temperature (low- N u ) wake appears downstream of each rib, particularly behind the first row, while cooler inter-rib zones mark regions of renewed mixing. As R e increases, boundary layers thin and reattachment moves upstream, but SR-B consistently maintains lower peak wall temperatures in inter-rib regions owing to spanwise curvature-driven stirring. Configuration SR-B therefore enhances area-mean heat transfer relative to TR-A across the full Reynolds range.
Figure 7. Temperature contours on the heated surface of the test section for cases (a) TR-A and (b) SR-B at different R e . The mainstream direction is from left to right; panels are ordered by increasing Re.
Figure 8. Local Nu contours on the heated surface of the test section for cases (a) TR-A and (b) SR-B at different Re. The mainstream direction is from left to right; panels are ordered by increasing Re.

3.3. Friction Factors

Figure 9 presents normalized friction factors for all ribbed channel configurations [39,83]. Layouts with high heat transfer generally incur higher friction, except SR-I. SR-E exhibits the highest normalized friction over R e = 20,000 – 90,000 . Among the row-modulated layouts, SR-D and SR-F can fall below some uniform high-amplitude cases (e.g., SR-C), whereas rib-height schedules (SR-G–SR-I) further modulate the trend. As discussed in Section 2.3, the steeper rise in f / f 0 for SR-B and SR-C between R e = 80,000 and 90,000 reflects stronger blockage–separation coupling at large uniform streamwise amplitudes ( b = 30 and 50 mm), where additional shear and recirculation develop without a proportional gain in area-mean N u / N u 0 .
Figure 9. Normalized friction factors ( f / f 0 ) over Re = 20,000–90,000 for all ribbed channel configurations.

3.4. Flow Characteristics

Thermal differences among sinusoidal configurations stem from differences in flow structure [84,85,86]. Figure 10 shows turbulent kinetic energy and streamlines on the x–y plane at z = 5 mm for TR-A and SR-B. Compared with transverse ribs, sinusoidal ribs strengthen secondary flow and raise turbulent kinetic energy between adjacent ribs over R e = 20,000 – 90,000 , with the clearest differences at R e = 60,000 – 90,000 ; curvature induces spanwise motion that disrupts the two-dimensional separation bubble typical of transverse ribs.
Figure 10. Surface streamlines and turbulent kinetic energy distributions on the x–y cross-section at z = 5 mm over Re = 20,000–90,000 for (a) TR-A and (b) SR-B.
Figure 11 shows x-velocity, streamlines, and temperature on the z–y cross section at x = 160 mm from the test-section inlet (near the first rib row) and R e = 20,000 . Although a single planar cut understates three-dimensional reattachment, TR-A still exhibits a larger coherent separation vortex than the more fragmented recirculation in the sinusoidal cases. Separation downstream of each rib forms a recirculation region before reattachment [87], which governs bottom-wall heat transfer [67]; low-velocity fluid in the TR-A wake corresponds to the poorly cooled zone in Figure 11b.
Figure 11. Distribution of (a) x-velocities and streamlines, and (b) temperatures on the z–y cross section at x = 160 mm from the test-section inlet and Re = 20,000 for all ribbed channels.
Because a single z–y cut under-represents three-dimensional reattachment, spanwise-averaged distributions of local N u l and wall-parallel shear magnitude on the heated wall were extracted along streamwise distance within the first inter-rib pitch from the same steady CFD fields used for Figure 5, Figure 6, Figure 7 and Figure 8. For TR-A, spanwise-averaged N u l shows a broad minimum beneath the coherent recirculation inferred from Figure 11a and then rises toward reattachment farther downstream. For SR-B and the other sinusoidal layouts, the low- N u l footprint is shorter in the streamwise direction and recovery begins earlier, matching the smaller and more fragmented recirculation suggested by the cross-sectional streamlines. Wall shear exhibits a complementary pattern—depressed under the separation region and elevated near reattachment—which localizes impingement more objectively than the isolated plane in Figure 11 alone.

3.5. Overall Thermal Performance

This subsection evaluates overall thermal performance in the sinusoidal rib channels on the uniform basis established in Section 2.4: every layout uses the same smooth-channel references N u 0 and f 0 from Equations (9) and (10), the same bulk temperature T f , and the same test-section length in f. TR-A is the transverse baseline. Figure 12 and Figure 13 plot O P T 1 and O P T 2 from Equations (7) and (8) [27,35,40], respectively.
Figure 12. Overall thermal performance factor OPT1 for various ribbed channel configurations over Re = 20,000–90,000.
Figure 13. Overall thermal performance factor OPT2 for various ribbed channel configurations over Re = 20,000–90,000.
The two definitions weigh heat-transfer gain against pressure loss differently. For all sinusoidal configurations, O P T 1 generally decreases with increasing Reynolds number (Figure 12) because f / f 0 rises faster than N u / N u 0 as the boundary layer thins and rib wakes strengthen. The streamwise-increasing height schedule (SR-I) achieves the highest O P T 1 over the full R e range shown: small upstream ribs limit early blockage while downstream ribs sustain mixing. By contrast, O P T 2 varies more weakly with R e than O P T 1 (Figure 13), and the large-amplitude uniform layout (SR-C) achieves the highest O P T 2 from R e = 40,000 to 90,000 because the ( f / f 0 ) 1 / 3 exponent dampens the friction penalty of large streamwise waviness while preserving high N u / N u 0 .
Values of O P T 1 below unity (Figure 12) are physically consistent with the definitions in Equations (7) and (8). Ribbed passages in the simulations typically achieve a N u / N u 0 of order 1.5 –3 while their f / f 0 often exceeds 5–8, so their ratio naturally falls in the 0.2 – 0.6 band. Values in the literature near or above unity frequently adopt different friction definitions (Darcy versus Fanning), reference lengths, or smooth-duct baselines [20,27]; those choices rescale the denominator without changing the underlying separation–mixing physics. The present indices are therefore used as relative ranking metrics among the nine sinusoidal layouts and TR-A under one documented normalization.
SR-I (heights 2–4–6–8–10 mm) leads O P T 1 because small upstream ribs add little blockage yet elevate mixing progressively toward downstream ribs that impose larger blockage; augmentation rises without the uniformly high friction seen in layouts such as SR-E. SR-C (uniform amplitude b = 50 mm, e = 10 mm) leads O P T 2 over R e = 40,000 – 90,000 because the ( f / f 0 ) 1 / 3 weighting de-emphasizes pressure loss while large amplitude sustains high N u / N u 0 . Thus, SR-I suits coolant- or pressure-drop-limited designs, whereas SR-C favors maximum heat removal when a higher Δ p is acceptable.
Cases SR-D, SR-E, and SR-F couple row-wise changes in amplitude b and wave number k. SR-D uses a symmetric b profile (10–30–50–30–10 mm) with k = 4 on the center row, producing strong centerline secondary motion while tapered ends curb friction. SR-E keeps b = 30 mm but alternates k = 2 and k = 4 , heightening spanwise modulation and breaking up the rib wake on selected rows. SR-F pairs an asymmetric b profile (50–30–20–30–50 mm) with alternating k, reducing mid-duct streamwise amplitude ( b = 20 mm at row 3) relative to SR-D while preserving augmentation. SR-D and SR-F primarily modulate row-resolved streamwise amplitude, whereas SR-E primarily tunes spanwise structure. All three occupy intermediate O P T 1 and O P T 2 positions between SR-I and SR-C for balanced design targets.
Relative to prior wavy-rib studies on the same normalization basis ( N u / N u 0 , f / f 0 from smooth-duct references), Wang et al. [47] report N u / N u 0 = 1.5 – 2.5 and f / f 0 ≈ 3 –6 for continuous wavy ribs in a square duct at R e = 20,000 – 60,000 ; Wang et al. [51] show strong sensitivity of both metrics to sinusoidal parameters. The present ranges ( N u / N u 0 ≈ 1.5 – 3.0 , f / f 0 ≈ 2 –8) are of the same order despite the 4:1 aspect ratio and discrete multi-row ribs. Larger streamwise amplitude raises both heat transfer and loss, while row-wise modulation yields intermediate trade-offs. Angled and V-shaped ribs in similar R e ranges often report comparable or higher N u / N u 0 at the expense of larger f / f 0 [20,24,25,26,37,38]. The sinusoidal layouts studied here do not uniformly outperform those established geometries on every metric; rather, selected cases (notably SR-I and SR-C) improve the trade-off relative to the transverse baseline in this channel class.

4. Conclusions

Nine multi-row sinusoidal rib layouts were compared with a transverse baseline in a 4:1 rectangular channel for Re = 20,000–90,000 using steady three-dimensional CFD with SST k– ω closure. The main results are as follows.
1.
Sinusoidal ribs raise the area-mean N u / N u 0 relative to the transverse baseline across R e = 20,000 – 90,000 ; the gain increases with streamwise amplitude and is further modulated by spanwise wave count and row-wise height schedules (SR-G–SR-I). Most layouts incur higher f / f 0 ; SR-I is comparatively favorable on friction, whereas SR-E gives the largest normalized friction. Rankings of h ¯ and S t ¯ follow those of N u ¯ because S t / S t 0 = N u / N u 0 at fixed R e and P r .
2.
SR-I (streamwise-increasing heights) achieves the highest O P T 1 over the full R e range; SR-C (large uniform amplitude) achieves the highest O P T 2 from R e = 40,000 to 90,000 . Coolant- or pressure-drop-limited designs should prioritize SR-I; heat-transfer-dominated targets should prioritize SR-C; SR-D, SR-E, and SR-F offer intermediate trade-offs.
3.
Results assume uniform heat flux on one wall, a short hydrodynamic inlet (≈3.9 D h ), a stationary duct, and steady incompressible CFD with SST k– ω closure. Absolute N u and f may change with inlet treatment, rotation, or buoyancy, even if relative rankings are more robust. Smooth-channel verification and mesh convergence are given in Section 2; geometry-matched experiments (e.g., Liu et al. [36] for perforated ribs) or higher-fidelity simulations remain desirable for quantitative confirmation of the sinusoidal layouts.
4.
Within the rib-channel literature on transverse, angled, and compound turbulators, this study provides a compact nine-case comparison of row-wise sinusoidal ribs against a transverse reference.
Future work may include geometry-matched experiments on selected sinusoidal layouts and, where feasible, rotation, buoyancy, conjugate walls, and wall-resolved LES under the same operating window.

Author Contributions

Conceptualization, Z.-G.R. and W.W.; methodology, Z.-G.R. and L.X.; software, Z.-G.R.; validation, W.W.; formal analysis, Z.-G.R.; investigation, W.W. and L.X.; resources, L.-H.Z.; data curation, W.W.; writing—original draft preparation, L.X. and Z.-G.R.; writing—review and editing, Z.-G.R. and W.W.; visualization, W.W.; supervision, W.W. and L.X.; project administration, L.X. and W.W.; funding acquisition, L.X. and L.-H.Z. All authors have read and agreed to the published version of the manuscript.

Funding

This centering research was funded by the Full Time Researchers from Zhejiang University Hainan Research Institute Launch Project, grant number 0210-6602-2025042336, and the Talent Introduction Project of Hubei Polytechnic University, grant numbers 24xjz22R and 22xjz23R.

Data Availability Statement

The data reported herein are available from the corresponding author on request.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Nourin, F.N.; Amano, R.S. Review of Gas Turbine Internal Cooling Improvement Technology. J. Energy Resour. Technol. 2021, 143, 080801. [Google Scholar] [CrossRef] [Scilit]
  2. Yeranee, K.; Rao, Y. A Review of Recent Studies on Rotating Internal Cooling for Gas Turbine Blades. Chin. J. Aeronaut. 2021, 34, 85–113. [Google Scholar] [CrossRef] [Scilit]
  3. Zhang, G.; Zhu, R.; Xie, G.; Li, S.; Sundén, B. Optimization of Cooling Structures in Gas Turbines: A Review. Chin. J. Aeronaut. 2022, 35, 18–46. [Google Scholar] [CrossRef] [Scilit]
  4. Gupta, S.; Chaube, A.; Verma, P. Review on Heat Transfer Augmentation Techniques: Application in Gas Turbine Blade Internal Cooling. J. Eng. Sci. Technol. Rev. 2012, 5, 57–62. [Google Scholar] [CrossRef] [Scilit]
  5. Xie, G.; Liu, X.; Yan, H. Film Cooling Performance and Flow Characteristics of Internal Cooling Channels with Continuous/Truncated Ribs. Int. J. Heat Mass Transf. 2017, 105, 67–75. [Google Scholar] [CrossRef] [Scilit]
  6. Wang, W.; Cui, J.; Qu, S. Effects of Hole Arrangement and Trenched Hole on Multirow Film Cooling. AIP Adv. 2022, 12, 045205. [Google Scholar] [CrossRef] [Scilit]
  7. Zheng, S.F.; Liu, G.Q.; Zhang, Y.; Wang, H.C.; Gao, S.R.; Yang, Y.R.; Li, H.W.; Sundén, B.; Wang, X.D. Performance Evaluation with Turbulent Flow and Heat Transfer Characteristics in Rectangular Cooling Channels with Various Novel Hierarchical Rib Schemes. Int. J. Heat Mass Transf. 2023, 214, 124459. [Google Scholar] [CrossRef] [Scilit]
  8. Baek, S.I.; Ahn, J. Large Eddy Simulation of Film Cooling with Triple Holes: Injectant Behavior and Adiabatic Film-Cooling Effectiveness. Processes 2020, 8, 1443. [Google Scholar] [CrossRef] [Scilit]
  9. Fox, D.W.; Jones, F.B.; McClintic, J.W.; Bogard, D.G.; Dyson, T.E.; Webster, Z.D. Rib Turbulator Effects on Crossflow-Fed Shaped Film Cooling Holes. J. Turbomach. 2019, 141, 031013. [Google Scholar] [CrossRef] [Scilit]
  10. Lee, H.J.; Park, H.S.; Kim, G.; Kim, Y.; Kim, S.; Cho, H.H. Enhanced External Wall Cooling Using Pyramid-Shaped Fins in Double-Wall Cooling of Gas Turbine Blade. Appl. Therm. Eng. 2026, 284, 129131. [Google Scholar] [CrossRef] [Scilit]
  11. Cui, H.; Wang, L.; Li, X.; Ren, J. Data-Driven Conjugate Heat Transfer Analysis of a Gas Turbine Vane. Processes 2022, 10, 2335. [Google Scholar] [CrossRef] [Scilit]
  12. Shi, Z.; Liu, C.; Jia, Y.; He, X.; Xia, G.; Liu, Y. Optimizing Film Cooling Hole Arrangement Along Conjugate Isotherms on Turbine Vanes: A Combined Numerical and Experimental Investigation. Processes 2025, 13, 3344. [Google Scholar] [CrossRef] [Scilit]
  13. Liu, J.; Hussain, S.; Wang, J.; Wang, L.; Xie, G.; Sundén, B. Heat Transfer Enhancement and Turbulent Flow in a High Aspect Ratio Channel (4:1) with Ribs of Various Truncation Types and Arrangements. Int. J. Therm. Sci. 2018, 123, 99–116. [Google Scholar] [CrossRef] [Scilit]
  14. Alfarawi, S.; Abdel-Moneim, S.A.; Bodalal, A. Experimental Investigations of Heat Transfer Enhancement from Rectangular Duct Roughened by Hybrid Ribs. Int. J. Therm. Sci. 2017, 118, 123–138. [Google Scholar] [CrossRef] [Scilit]
  15. Zhang, B.X.; Wang, L.Q.; Lu, W.; Xu, J.H.; Wang, Y.B.; Yang, Y.R.; Wang, X.D. Performance Evaluation and Enhancement of Turbulent Flow and Convective Heat Transfer Characteristics for Turbine Blade Internal Cooling. Phys. Fluids 2024, 36, 035152. [Google Scholar] [CrossRef] [Scilit]
  16. Abraham, S.; Vedula, R. Heat Transfer and Pressure Drop Measurements in a Square Cross-Section Converging Channel with V and W Rib Turbulators. Exp. Therm. Fluid Sci. 2016, 70, 208–219. [Google Scholar] [CrossRef] [Scilit]
  17. Elmenshawy, A.A.A.E.; Alomar, I.; Arshad, A. Optimization Turbine Blade Cooling by Applying Jet Impingement Cooling Channels. Transp. Telecommun. J. 2023, 24, 320–337. [Google Scholar] [CrossRef] [Scilit]
  18. Wang, X.; Xu, H.; Wang, J.; Song, W.; Wang, L. High Pressure Turbine Blade Internal Cooling in a Realistic Rib Roughened Two-Pass Channel. Int. J. Heat Mass Transf. 2021, 170, 121019. [Google Scholar] [CrossRef] [Scilit]
  19. Huh, M.; Han, J.-C. Recent Studies in Turbine Blade Internal Cooling. Heat Transf. Res. 2010, 41, 803–828. [Google Scholar] [CrossRef] [Scilit]
  20. Han, J.-C.; Chen, H.-C. Turbine Blade Internal Cooling Passages with Rib Turbulators. J. Propuls. Power 2006, 22, 226–248. [Google Scholar] [CrossRef] [Scilit]
  21. Lei, J.; Han, J.C.; Huh, M. Effect of Rib Spacing on Heat Transfer in a Two Pass Rectangular Channel (AR = 2:1) at High Rotation Numbers. J. Heat Transf. 2012, 134, 091901. [Google Scholar] [CrossRef] [Scilit]
  22. Marocco, L.; Franco, A. Direct Numerical Simulation and RANS Comparison of Turbulent Convective Heat Transfer in a Staggered Ribbed Channel with High Blockage. J. Heat Transf. 2017, 139, 021701. [Google Scholar] [CrossRef] [Scilit]
  23. Dinh, C.T.; Nguyen, T.M.; Vu, T.D.; Park, S.G.; Nguyen, Q.H. Numerical Investigation of Truncated-Root Rib on Heat Transfer Performance of Internal Cooling Turbine Blades. Phys. Fluids 2021, 33, 076104. [Google Scholar] [CrossRef] [Scilit]
  24. Wright, L.M.; Han, J.-C. Heat Transfer Enhancement for Turbine Blade Internal Cooling. J. Enhanc. Heat Transf. 2014, 21, 111–140. [Google Scholar] [CrossRef] [Scilit]
  25. Satta, F.; Simoni, D.; Tanda, G. Experimental Investigation of Flow and Heat Transfer in a Rectangular Channel with 45° Angled Ribs on One/Two Walls. Exp. Therm. Fluid Sci. 2012, 37, 46–56. [Google Scholar] [CrossRef] [Scilit]
  26. Yang, W.; Xue, S.; He, Y.; Li, W. Experimental Study on the Heat Transfer Characteristics of High Blockage Ribs Channel. Exp. Therm. Fluid Sci. 2017, 83, 248–259. [Google Scholar] [CrossRef] [Scilit]
  27. Mahmood, G.I.; Ligrani, P.M.; Chen, K. Variable Property and Temperature Ratio Effects on Nusselt Numbers in a Rectangular Channel With 45 Deg Angled Rib Turbulators. J. Heat Transf. 2003, 125, 769–778. [Google Scholar] [CrossRef] [Scilit]
  28. Keshmiri, A.; Gotts, J. Thermalhydraulic Analysis of Four Geometrical Design Parameters in Rib-Roughened Channels. Numer. Heat Transf. Part A Appl. 2011, 60, 305–327. [Google Scholar] [CrossRef] [Scilit]
  29. Ligrani, P. Heat Transfer Augmentation Technologies for Internal Cooling of Turbine Components of Gas Turbine Engines. Int. J. Rotating Mach. 2013, 2013, 1–32. [Google Scholar] [CrossRef] [Scilit]
  30. Jeong, H.-S.; Seo, J.-W.; Kim, K.-Y. Multiobjective Optimization of a Slit Rib in a Rectangular Cooling Channel. Heat Transf. Res. 2018, 49, 395–412. [Google Scholar] [CrossRef] [Scilit]
  31. Tanda, G. Effect of rib spacing on heat transfer and friction in a rectangular channel with 45° angled rib turbulators on one/two walls. Int. J. Heat Mass Transf. 2011, 54, 1081–1090. [Google Scholar] [CrossRef] [Scilit]
  32. Chung, H.; Park, J.S.; Park, S.; Choi, S.M.; Rhee, D.H.; Cho, H.H. Augmented Heat Transfer with Intersecting Rib in Rectangular Channels Having Different Aspect Ratios. Int. J. Heat Mass Transf. 2015, 88, 357–367. [Google Scholar] [CrossRef] [Scilit]
  33. Matsubara, K.; Ohta, H.; Miura, T. Entrance Region Heat Transfer in a Channel with a Ribbed Wall. J. Heat Transf. 2016, 138, 122001. [Google Scholar] [CrossRef] [Scilit]
  34. Satta, F.; Tanda, G.; Venturino, G. Effect of Entrance Geometry on Heat Transfer in a Rib-Roughened Rectangular Channel. Heat Transf. Eng. 2022, 43, 623–637. [Google Scholar] [CrossRef] [Scilit]
  35. Zhang, M.; Singh, P.; Ekkad, S.V. Rib Turbulator Heat Transfer Enhancements at Very High Reynolds Numbers. J. Therm. Sci. Eng. Appl. 2019, 11, 061014. [Google Scholar] [CrossRef] [Scilit]
  36. Liu, J.; Hussain, S.; Wang, W.; Wang, L.; Xie, G.; Sundén, B. Heat Transfer Enhancement and Turbulent Flow in a Rectangular Channel Using Perforated Ribs with Inclined Holes. J. Heat Transf. 2019, 141, 041702. [Google Scholar] [CrossRef] [Scilit]
  37. Singh, P.; Pandit, J.; Ekkad, S. Characterization of Heat Transfer Enhancement and Frictional Losses in a Two-Pass Square Duct Featuring Unique Combinations of Rib Turbulators and Cylindrical Dimples. Int. J. Heat Mass Transf. 2017, 106, 629–647. [Google Scholar] [CrossRef] [Scilit]
  38. Singh, P.; Ekkad, S. Experimental Study of Heat Transfer Augmentation in a Two-Pass Channel Featuring V-Shaped Ribs and Cylindrical Dimples. Appl. Therm. Eng. 2017, 116, 205–216. [Google Scholar] [CrossRef] [Scilit]
  39. Choi, E.Y.; Choi, Y.D.; Lee, W.S.; Chung, J.T.; Kwak, J.S. Heat Transfer Augmentation Using a Rib-Dimple Compound Cooling Technique. Appl. Therm. Eng. 2013, 51, 435–441. [Google Scholar] [CrossRef] [Scilit]
  40. Tamang, S.; Ali, E.; Park, H. A Novel Concept for a Rib Turbulator for Optimizing the Cooling Performance in a Square Channel. Int. J. Heat Mass Transf. 2024, 221, 125144. [Google Scholar] [CrossRef] [Scilit]
  41. Yang, C.; Ren, L.; Zheng, D.; Sun, J. Heat Transfer and Friction Characteristics in a Rectangular Channel with Rib-Grooved Turbulators. AIP Adv. 2025, 15, 115232. [Google Scholar] [CrossRef] [Scilit]
  42. Chang, S.W.; Huang, B.J. Thermal performance of undulant narrow channel with skewed sinusoidal wall-waves and 45° ribs. Int. J. Heat Mass Transf. 2012, 55, 3167–3177. [Google Scholar] [CrossRef] [Scilit]
  43. Forster, M.; Ligrani, P.; Weigand, B.; Poser, R. Experimental and numerical investigation of jet impingement cooling onto a rib roughened concave internal passage for leading edge cooling of a gas turbine blade. Int. J. Heat Mass Transf. 2024, 227, 125572. [Google Scholar] [CrossRef] [Scilit]
  44. Kumar, A.; Pathak, M. Flow and heat transfer characteristics of gas turbine blade channels with compound V-rib-dimple structures. Int. Commun. Heat Mass Transf. 2024, 157, 107823. [Google Scholar] [CrossRef] [Scilit]
  45. Majmader, F.B.; Hasan, M.J. Effects of bidirectional rib arrangements on turbulent flow structure and heat transfer characteristics of a two-pass channel for turbine blade internal cooling. Int. Commun. Heat Mass Transf. 2024, 156, 107688. [Google Scholar] [CrossRef] [Scilit]
  46. Wang, L.; Liu, X.; Cui, T.; Mao, J.; Lv, C.; Zhang, D.; Liu, Y.; Li, M. Multi-objective analysis of the turbine blade internal cooling channel with discontinuous bionic S-shaped ribs. Int. J. Therm. Sci. 2025, 207, 109371. [Google Scholar] [CrossRef] [Scilit]
  47. Wang, L.; Wang, S.; Wen, F.; Zhou, X.; Wang, Z. Effects of Continuous Wavy Ribs on Heat Transfer and Cooling Air Flow in a Square Single-Pass Channel of Turbine Blade. Int. J. Heat Mass Transf. 2018, 121, 514–533. [Google Scholar] [CrossRef] [Scilit]
  48. Chang, S.W.; Liou, T.M.; Yu, K.C.; Huang, S.S. Thermal-hydraulic performance of longitudinal wavy rib along wavy two-pass channel. Appl. Therm. Eng. 2018, 133, 224–236. [Google Scholar] [CrossRef] [Scilit]
  49. Wang, J.S.; Gao, X.M.; Li, W.Y. Flow and heat transfer characteristics in a channel having furrowed wall based on sinusoidal wave. Korean J. Chem. Eng. 2015, 32, 2187–2203. [Google Scholar] [CrossRef] [Scilit]
  50. Jo, J.; Kim, S.J. Conjugate heat transfer by oscillating flow in a parallel-plate channel subject to a sinusoidal wall temperature distribution. Appl. Therm. Eng. 2017, 123, 1462–1472. [Google Scholar] [CrossRef] [Scilit]
  51. Wang, L.; Liu, X.; Mao, J.; Lv, C.; Zhang, D.; Liu, Y.; Li, M. Analyzing the Impact of Sinusoidal Wavy Rib Geometric Parameters on Turbine Blade Thermal and Fluid Dynamics. Int. J. Therm. Sci. 2024, 203, 109162. [Google Scholar] [CrossRef] [Scilit]
  52. Harikrishnan, S.; Tiwari, S. Effect of Top Wall Configuration on Unsteady Flow and Heat Transfer Characteristics of Sinusoidal Wavy Channels. Heat Transf. Eng. 2022, 43, 423–436. [Google Scholar] [CrossRef] [Scilit]
  53. Gao, T.; Zhu, J.; Li, J.; Xia, Q. Numerical Study of the Influence of Rib Orientation on Heat Transfer Enhancement in Two-Pass Ribbed Rectangular Channel. Eng. Appl. Comput. Fluid Mech. 2018, 12, 117–136. [Google Scholar] [CrossRef] [Scilit]
  54. Guha, A.; Krishnan, J.J. Mathematical theory and CFD solutions for internal convective cooling of gas turbine blades highlighting the effects of rotation. Appl. Therm. Eng. 2025, 259, 124638. [Google Scholar] [CrossRef] [Scilit]
  55. Saha, K.; Acharya, S. Effect of Bend Geometry on Heat Transfer and Pressure Drop in a Two-Pass Coolant Square Channel for a Turbine. J. Turbomach. 2013, 135, 021035. [Google Scholar] [CrossRef] [Scilit]
  56. Zhang, D.; Jing, Q.; Xie, Y.; Shen, Z. Numerical Prediction on Turbine Blade Internal Tip Cooling with Pin-Fin and Dimple/Protrusion Structures. Numer. Heat Transf. Part A Appl. 2016, 70, 1021–1040. [Google Scholar] [CrossRef] [Scilit]
  57. Liu, J.; Wang, J.; Yang, K. Heat Transfer Enhancement in a Triple-Layered Turbine Blade Internal Cooling Channel. Appl. Therm. Eng. 2024, 248, 123341. [Google Scholar] [CrossRef] [Scilit]
  58. Liu, J.; Wang, J.; Yang, K. Heat Transfer Enhancement by Employing Inserted Plate in Turbine Blade Internal Cooling Channel. Case Stud. Therm. Eng. 2023, 45, 102977. [Google Scholar] [CrossRef] [Scilit]
  59. Liu, J.; Wang, J.; Yang, K. Experimental investigations of the convective and radiative synergistic heat transfer enhancement in turbine blade internal cooling channel. Int. J. Therm. Sci. 2026, 224, 110713. [Google Scholar] [CrossRef] [Scilit]
  60. Li, M.; Yang, K.; Wang, H.; Yu, R.; Tong, J. Effect of Baffle on Heat Transfer Performance of Turbine Blade Composite Cooling Channel Based on Latticework. Machines 2025, 13, 177. [Google Scholar] [CrossRef] [Scilit]
  61. Tolu, M.E.; Babayigit, O.; Ozen, D.N. Investigation of the Effects of Rib Application on Cooling in a Turbine Blade. Konya J. Eng. Sci. 2025, 13, 11–24. [Google Scholar] [CrossRef] [Scilit]
  62. Nourin, F.N.; Raihan, M.T.; Amano, R.S. Exploring the Effects of Pin-Fins in a Gas Turbine Blade Internal Cooling Channel. Int. J. Energy Clean Environ. 2025, 26, 67–94. [Google Scholar] [CrossRef] [Scilit]
  63. Wen, J.; Zhu, C.; Chen, Y.; Xu, G.; Li, H.; Wang, J. Rotational Flow and Heat Transfer in a Serpentine Cooling Channel with Realistic Internal Cooling Schemes of a Turbine Blade. Int. J. Therm. Sci. 2025, 214, 109863. [Google Scholar] [CrossRef] [Scilit]
  64. Otmani, A.; Benmehidi, N.; Kahaleras, M.S.; Khatir, H.; Azzouz, S.E. Design of Turbine Blade Internal Cooling: A Thermofluidic Study on the Influence of Varying Cooling Channel Numbers and Configurations. Therm. Eng. 2025, 72, 181–191. [Google Scholar] [CrossRef] [Scilit]
  65. Xiang, Z.; Liu, Q.; Han, S.; Qi, S.; Huo, T.; Zhang, R.; Zhou, L.; Li, L.; Zhang, H.; Du, X. Enhanced Cooling Performance in Turbine Blade Tip U-Channel Using Protrusion-V-Rib Composite Structure. Int. J. Heat Fluid Flow 2026, 118, 110218. [Google Scholar] [CrossRef] [Scilit]
  66. Wörz, B.; Wieler, M.; Dehe, V.; Jeschke, P.; Rabs, M. Heat Transfer in a Square Ribbed Channel: Evaluation of Turbulent Heat Transfer Models. Int. J. Turbomach. Propuls. Power 2019, 4, 18. [Google Scholar] [CrossRef] [Scilit]
  67. Liu, J.; Hussain, S.; Wang, W.; Xie, G.; Sundén, B. Experimental and Numerical Investigations of Heat Transfer and Fluid Flow in a Rectangular Channel with Perforated Ribs. Int. Commun. Heat Mass Transf. 2021, 121, 105083. [Google Scholar] [CrossRef] [Scilit]
  68. Zhang, G.; Sundén, B.; Xie, G. Combined Experimental and Numerical Investigations on Heat Transfer Augmentation in Truncated Ribbed Channels Designed by Adopting Fractal Theory. Int. Commun. Heat Mass Transf. 2021, 121, 105080. [Google Scholar] [CrossRef] [Scilit]
  69. Ravi, B.V.; Singh, P.; Ekkad, S.V. Numerical Investigation of Turbulent Flow and Heat Transfer in Two-Pass Ribbed Channels. Int. J. Therm. Sci. 2017, 112, 31–43. [Google Scholar] [CrossRef] [Scilit]
  70. Xie, G.; Zheng, S.; Zhang, W.; Sundén, B. A Numerical Study of Flow Structure and Heat Transfer in a Square Channel with Ribs Combined Downstream Half-Size or Same-Size Ribs. Appl. Therm. Eng. 2013, 61, 289–300. [Google Scholar] [CrossRef] [Scilit]
  71. Ahn, J.; Song, J.C.; Lee, J.S. Large Eddy Simulation of Conjugate Heat Transfer in a Ribbed Channel: Reynolds Number Effect. Processes 2022, 10, 1928. [Google Scholar] [CrossRef] [Scilit]
  72. Chanda, S.; Dhamudia, K.; Senapati, J.R. Heat Transfer Enhancement Using Rivet-Type Rib Turbulators in a Rectangular Channel: A CFD Study. Therm. Sci. Eng. Prog. 2025, 66, 104019. [Google Scholar] [CrossRef] [Scilit]
  73. Ahn, J.; Lee, J.S. Large eddy simulation of flow and heat transfer in a channel with a detached rib array. Int. J. Heat Mass Transf. 2010, 53, 445–452. [Google Scholar] [CrossRef] [Scilit]
  74. Kumar, S.; Amano, R.S.; Lucci, J.M. Numerical simulations of heat transfer distribution of a two-pass square channel with V-rib turbulator and bleed holes. Heat Mass Transf. 2013, 49, 1141–1158. [Google Scholar] [CrossRef] [Scilit]
  75. Ahn, J. Large Eddy Simulation of Flow and Heat Transfer in a Ribbed Channel for the Internal Cooling Passage of a Gas Turbine Blade: A Review. Energies 2023, 16, 3656. [Google Scholar] [CrossRef] [Scilit]
  76. Hameed, H.M.R.; Zaharuddin, M.F.A. Enhancing Gas Turbine Blade Cooling Efficiency: A Computational Fluid Dynamics Study of Turbulator Impact. Int. J. Heat Technol. 2025, 43, 625–632. [Google Scholar] [CrossRef] [Scilit]
  77. Kim, D.H.; Lee, B.J.; Park, J.S.; Kwak, J.S.; Chung, J.T. Effects of Inlet Velocity Profile on Flow and Heat Transfer in the Entrance Region of a Ribbed Channel. Int. J. Heat Mass Transf. 2016, 92, 838–849. [Google Scholar] [CrossRef] [Scilit]
  78. Menter, F.R. Two-equation eddy-viscosity turbulence models for engineering applications. AIAA J. 1994, 32, 1598–1605. [Google Scholar] [CrossRef] [Scilit]
  79. Xu, W.; Liu, G.; Zhang, Q.; Wang, S.; Lu, H.; Tan, H. Heat Transfer and Friction Factor of Therminol Liquid Phase Heat Transfer Fluid in a Ribbed Tube. Chin. J. Chem. Eng. 2017, 25, 1343–1351. [Google Scholar] [CrossRef] [Scilit]
  80. Tamang, S.; Park, H. Optimization of Heat Transfer in Mist/Steam Cooled Square Channel with Kink Angled Rib Turbulator. Int. Commun. Heat Mass Transf. 2023, 140, 106553. [Google Scholar] [CrossRef] [Scilit]
  81. Celik, I.B.; Ghia, U.; Roache, P.J.; Freitas, C.J.; Coleman, H.; Raad, P.E. Procedure for Estimation and Reporting of Uncertainty Due to Discretization in CFD Applications. J. Fluids Eng. 2008, 130, 078001. [Google Scholar] [CrossRef] [Scilit]
  82. Kumar, A.; Layek, A. Nusselt Number-Friction Characteristic for a Twisted Rib Roughened Rectangular Duct Using Liquid Crystal Thermography. Exp. Therm. Fluid Sci. 2018, 97, 205–217. [Google Scholar] [CrossRef] [Scilit]
  83. Yan, H.; Chen, Z.; Luo, L.; Du, W.; Zeng, F.; Wang, S.; Guo, L. Heat Transfer Enhancement of Return Channel by Using Rib Turbulator for a New Impingement Cooling Scheme. Int. Commun. Heat Mass Transf. 2024, 151, 107237. [Google Scholar] [CrossRef] [Scilit]
  84. Zhao, K.; Lin, W.; Li, X.; Ren, J. Effect of Micro Rib on Aerothermal Dynamic in Channel Flow. Int. J. Heat Mass Transf. 2021, 178, 121573. [Google Scholar] [CrossRef] [Scilit]
  85. Miura, T.; Matsubara, K.; Sakurai, A. Heat Transfer Characteristics and Reynolds Stress Budgets in Single-Rib Mounting Channel. J. Therm. Sci. Technol. 2010, 5, 135–150. [Google Scholar] [CrossRef] [Scilit]
  86. Jagadeesan, K.; Narasimhamurthy, V.D. Reynolds Number Effects in Rib-Roughened Turbulent Channel Flow. Int. J. Adv. Eng. Sci. Appl. Math. 2019, 11, 254–262. [Google Scholar] [CrossRef] [Scilit]
  87. Cukurel, B.; Selcan, C.; Arts, T. Film Cooling Extraction Effects on the Aero-Thermal Characteristics of Rib Roughened Cooling Channel Flow. J. Turbomach. 2013, 135, 021016. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.