Abstract

The increasing risk of air pollution in closed areas like passenger vehicles requires smart and real-time air quality reading solutions. Gases such as carbon monoxide (CO)—which is colorless and odorless and is produced by exhaust systems—air conditioners, and combustion sources are very dangerous to health because they can cause respiratory distress and poisoning at high levels. Traditional in-vehicle CO monitoring systems use a single-point sensor and a fixed threshold, which are insufficient in a dynamic cabin environment subject to factors such as vehicle size, ventilation rate, number of occupants, and incoming traffic. To address these drawbacks, this paper proposes a new E-Nose system with Virtual Sensor-Augmented Embedded Intelligence to estimate the CO concentration in vehicle cabins in real time. The system combines data from cheap gas sensors and improves it using virtual sensor machine learning models trained to predict or enhance sensor responses in real time. Embedded intelligence, deployed locally on edge hardware, supports low-latency processing, dynamic calibration, and noise filtering to respond to fluctuating environmental conditions adaptively. This architecture enables more accurate, robust, and context-aware estimation of CO levels compared to traditional threshold-based methods. Experimental validation across varied vehicular scenarios demonstrates superior precision and responsiveness, providing timely warnings even under complex dispersion patterns. Classifier Gradient Boosting, which builds an ensemble of weak learners sequentially, matched the Random Forest with 99.94% training and 98.59% model accuracy, confirming its strong predictive capability. The system is designed to be cost-effective, scalable, and easily integrable into modern automotive platforms. This study also contributes to the field of smart ecological recording and demonstrates the effectiveness of the virtual sensor-enhanced embedded system as an effective way to improve passenger safety by providing pre-emptive on-board air quality monitoring.

1. Introduction

According to the American Automobile Association (AAA), sleepy drivers are to blame for one out of every six fatal traffic accidents and one out of every eight collisions that result in hospitalization. B.C. Tefft et al. estimated a sample of 47,597 incidents in the United States between 1999 and 2008 involving a passenger vehicle that was towed from the scene. Their study calculated the percentage of crashes involving a sleepy driver [1]. The air inside the vehicle cabin significantly affects the cognitive abilities of occupants, without causing noticeable discomfort that would put them on alert. According to the Royal Malaysia Police, drivers who are fatigued and distracted are the main causes of traffic accidents [2]. One simple way to reduce the harmful gases is to keep all windows and doors closed to keep outside pollutants out. Furthermore, the indoor space within vehicles can be considered similar to other indoor environments, such as a car cabin fitted with an HVAC system. The entry of pollutants such as particulate matter and dangerous gases emitted by the vehicle exhaust system can be reduced by HVAC systems through the recirculation mode (RC) [3,4].
This paper introduces an advanced E-Nose architecture for real-time in-vehicle carbon monoxide (CO) concentration estimation, aiming to improve vehicle air quality [5]. The architecture uses virtual sensors and embedded intelligence to estimate CO concentrations, enhancing passenger safety and well-being accurately [6]. The proposed E-Nose architecture uses virtual sensors and embedded intelligence to accurately estimate CO concentrations in real time. This system captures and analyzes responses from multiple gas sensors, providing a comprehensive understanding of CO concentrations, thereby safeguarding passengers from potential health hazards [7].
A study in Delhi suggests that using compressed natural gas (CNG) in non-commercial vehicles may not be as beneficial as previously thought, especially during summer. The study recommends a complete life-cycle analysis to account for increased electricity costs and sets minimum efficiency standards for CNG-converting engines. This will reduce Carbon Dioxide CO2 emissions and promote sustainability in urban areas. Policymakers should consider the full life cycle of alternative fuels and set minimum efficiency standards to reduce emissions and promote environmental regulation in urban areas [7,8,9]. The system’s real-time monitoring capabilities and potential integration with vehicle control systems will enhance passenger safety, reduce health risks, and improve vehicle air quality [10,11]. The proposed algorithms adhere to rigorous mathematical formulations and utilize a non-cloud-based, unsupervised TinyML method to eliminate outliers from the data stream, enhancing the soft sensor’s accuracy without cloud-based server interaction. The proposed implementation on the Freematics ONE+ board has demonstrated its viability, with an emission granularity measure of gCO2/km [12]. Shivnath et al. [13] have obtained effective virtual sensor responses (VSRs); they suggested the three-input and three-output (TITO) strategy, which performs better than their peer-reviewed, already published method. The suggested method is demonstrated with a GSA with four components. In comparison to its counterpart, our suggested method increases the VSRs by a factor of four. The IoT-enabled vehicle AQS system uses five sensors: CO, CO2, PM, temperature, and humidity, to measure the concentrations of these pollutants in the vehicle’s environment [14]. Figure 1 depicts the procedure for the E-Nose system, employing a real-time system for such tasks. It also shows the architecture of how the data is collected and predicted.
Figure 1. Integrated system architecture that represents the data collection structure as well as the real-time E-Nose system for gas sensing and analysis. Stepwise architecture: (1) MQ sensors detect CO (analog signal); (2) MCP3008 converts to digital; (3) Raspberry Pi acquires data; (4) data is stored in CSV; (5) normalization and ML classification; (6) model is deployed via pickle; (7) prediction of hazardous CO concentration.
This paper introduces a Virtual Sensor-Augmented Embedded Intelligence-based E-Nose framework, which integrates a virtual sensor and embedded intelligence to gather and process data of multiple MQ cross-selective gas sensors. The system has state-of-the-art machine learning (ML) algorithms to analyze and assess sensor data and has the capability to calculate the carbon monoxide (CO) level accurately and in real time. This technology breaks the constraints of traditional methods that use single-point sensors or threshold-based alarms and takes into account the change in CO concentrations brought about by such factors as vehicle size, ventilation, and traffic conditions. The novelty of this paper on a Virtual Sensor-Augmented Embedded Intelligence-Based novel E-Nose architecture for real-time in-vehicle CO estimation is determined by several main areas, such as the integration of virtual sensors and embedded systems, the highly developed algorithm for data processing, dynamic control of CO changes, the paramount consideration of passenger safety and well-being, and the encouragement of a sustainable urban environment. This paper presents the the importance, experimental design in a real-time setting, data-gathering procedures, data analysis procedures, and valuable conclusions on in-vehicle CO concentration monitoring and virtual sensors. Besides the issue of constructing a sensor for CO, a silent killer, this study provides valuable information on the applicability of the solution in reality. It describes in detail the experimental strategy, the data management, the data analysis methods, the results and conclusions, the recommendations for future research, and future scope. The proposed work is based on system-scale interaction with virtual sensing and embedded intelligence, as opposed to recent hardware-based sensing systems, which can be scaled and are less expensive than the new gas sensing system due to their low-cost attributes.

2. Literature Review

A suggestion that has been made by A Mishra et al. is that an in-cabin monitoring system (IMS) is essential for offering a solution to the problem of autonomous operations [15]. The suggested IMS will incorporate high-quality monitoring cameras and an OBD system with artificial intelligence (AI) to create a powerful E-Nose framework. It is aimed at optimizing the virtual sensors’ algorithms, the intelligent estimation of CO concentrations, and performance validation under real-life conditions. It also discusses the integration with vehicle control systems in order to have automated responses to CO levels. In the event that it is broadly used across vehicle types, the performance of an unoptimized gas sensor array serves as a baseline to compare the performance of the optimized gas sensor array [16]. To compare the performance of the optimized gas sensor array to that of the unoptimized gas sensor array, the performance of an unoptimized gas sensor array has been considered as a basis of comparison [17].
Specifically, there is much published literature that highlights the capabilities of the Raspberry Pi 4 board in applications such as real-time air quality monitoring, portable healthcare diagnostics and E-Noses in general. Sun et al. (2022) emphasized sensor-array optimization to reduce computational overhead [18], while Zhu et al. (2022) proposed the need for efficient sensor-selection strategies [19]. Wijaya et al. (2021) proposed an information-theoretic ensemble feature selection method with multi-stage aggregation to optimize E-Nose sensor arrays, ensuring robust generalization of gas sensor combinations [20]. Further, the techniques and algorithms used in E-Nose design and development have been thoroughly reviewed by Liu et al. (2023) [18]. Application-wise, volatile organic compound (VOC)-based plant water stress detection has been reported by Sharma et al. (2022) [21]. Zhai et al. (2022) used the Raspberry Pi 4 board as the main lower computer controller responsible for data collection, and experiments showed that the E-Nose system can identify different types of food in the refrigerator over a long period to determine food spoilage, ensuring the reliability and accuracy of the system [22]. Likewise, there are several published papers that report the use of the Raspberry Pi 4 board [23]. Mathe et al. (2024) reviewed the applications and capabilities of the Raspberry Pi 4 board in various fields such as remote and harsh environments, energy management, and healthcare, and also investigated its use in monitoring air quality, soil moisture, temperature, and humidity for irrigation control [24]. Misbah et al. (2018) developed a prototype model for the monitoring of air pollution [25]. Samourkasidis et al. (2016) provided added value services on site for indoor air pollution data acquisition scenarios [26]. Wicaksono et al. (2024) developed a system that uses IoT methodologies to monitor server rooms for parameters such as humidity, air quality, and temperature [27]. The platform integrates Python-based machine learning libraries, enabling lightweight, edge-level inference independent of cloud infrastructure. It further facilitates real-time analysis of sensor responses under vehicular conditions, accounting for factors such as sensor latency, transient and steady-state behavior, and sampling rate limitation [7]. Our experiments further evaluate the use of Normalized Difference Sensor Response Transformation (NDSRT) and zero-mean unit variance (ZMUV) techniques to generate robust virtual sensor responses, enhancing the discrimination of CO concentration levels [28]. The resulting system offers improved sensitivity, dynamic adaptability, and scalability for deployment across various vehicle platforms. Moreover, this research supports broader sustainability goals by promoting intelligent in-vehicle air quality systems that are low-cost, energy-efficient, and aligned with environmental safety standards. The outcomes demonstrate the feasibility and reliability of using virtual sensor-augmented embedded architectures for real-time in-vehicle CO monitoring, with potential integration into vehicular control systems for automated interventions [8].
This paper introduces an advanced E-Nose architecture for real-time in-vehicle carbon monoxide (CO) concentration estimation, aiming to improve air quality in vehicles. The architecture uses virtual sensors and embedded intelligence to accurately estimate CO concentrations, enhancing passenger safety and well-being. The proposed E-Nose architecture uses virtual sensors and embedded intelligence to accurately estimate CO concentrations in real time. This system captures and analyzes responses from multiple gas sensors, providing a comprehensive understanding of CO concentrations, thereby safeguarding passengers from potential health hazards. Raspberry Pi 4, a single-board computer (SBC), is a low-power, low-cost, limited-capability computing resource that is highly suitable for deploying machine learning models on the edge. In our research, we have demonstrated a good performance by using suitable models to deliver efficient results. The Raspberry Pi 4 board has shown its significant capability to run a full-fledged Debian-based Linux operating system supporting Python 3 and its associated machine learning libraries such as Scikit-learn, Tensor Flow, PyTorch, Keras, Seaborn, etc., along with several classification and boosting algorithms [29].
Automobile factories have gradually increased the number of sensors and the capabilities of vehicle control systems in order to improve performance and increase safety for drivers and passengers [30]. The OBD-II (On-Board Diagnostics) was launched as a system capable of self-diagnosing and alerting the driver about possible problems in the vehicle’s subsystems, such as electronic components and the status of the emission of pollutants. Since 1996, all vehicles manufactured in the United States have been required to support OBD-II, with other countries following the same trend [31]. Since the OBD-II system was introduced in major global markets, several strategies have been introduced to take advantage of the data produced and give drivers useful information [32]. The smart CO detection system uses an Arduino-based device to detect CO gas and display it on an LCD screen [33]. The development of carbon monoxide (CO) detection and estimation is vital since it has large health and safety impacts, as it is a colorless, odorless gas. Carbon monoxide (CO) is a highly hazardous gas that may lead to unconsciousness and potentially fatality or even a wide array of other significant disorders, such as headaches, nausea, and dizziness. The increasing worry over air pollution and its health hazards, especially in constricted areas such as vehicles, has led to the creation of a stable and efficient system that monitors carbon monoxide, which is commonly termed a silent killer because it is both odorless and colorless [34]. Vulnerable groups that are at a higher risk of CO effects include infants, the elderly and individuals with underlying medical conditions. Detection machines (equipment to detect CO) must be calibrated and maintained on a regular basis in order to give accurate readings and give warnings on time. Everything said and done, CO detection and estimation are the key to the preservation of people’s health and enhancing the general security of residential, business, and industrial areas [35]. Mishra et al. [15] suggested a valuable solution to the issues of autonomous operation through the provision of an effective in-cabin monitoring system (IMS). The IMS suggested in one study is based on the strong interrelation between innovative monitoring cameras and an on-board device (OBD), which is run by the power of artificial intelligence (AI). The given work will focus on the design and construction of the E-Nose architecture, the advancement of the virtual sensor algorithms, the introduction of intelligence into the estimation of CO concentration, and the testing of the proposed solution in a real-world environment. It goes further, discussing the linkage between the E-Nose architecture and vehicle control systems in order to take automatic measures according to the CO level. It is anticipated that a well-developed and valid in-vehicle CO concentration estimation system will be developed and can be applied to different types of vehicles [16]. Recent developments in system-level gas sensor integration have focused on the co-design of sensing hardware and embedded intelligence to facilitate compact, adaptive and real-time gas detection systems [36].

3. Materials and Methodology

In this study, we have implemented and evaluated several real-time operational classifiers. We have also typically evaluated and reported the performance of Decision Tree, Random Forest, K-Nearest Neighbor, and Gradient Boost algorithms, as used on the Raspberry Pi 4 board. In this experiment, metal-oxide semiconductor chemi-resistive sensors were used, which exhibit a response characteristic comprising a transient response followed by a steady-state response. These gas sensor elements operate on a continuous basis for varying concentrations of the analyte gas (CO). This change is gradual and a digital sampling rate faster than a few milliseconds should not be a matter of major concern. In the published literature as well as in the current experiment, the sampling rate was in the broad range of 1000 to 60,000 samples per second, whereas a popular processor, e.g., a Raspberry Pi 4 board operating at 1.5 Gigahertz (GHz), can provide a sampling rate as high as 10 12 samples per second. Figure 1 depicts the procedure for the E-Nose system, employing a real-time system for such tasks. It also shows the process of how the data is collected and predicted. Data acquisition was performed at a sampling rate of 10 12 samples per second, resulting in a total dataset size of 2484 samples. Each sample consists of an 8-dimensional sensor response vector, further augmented through virtual sensor transformation. Figure 1 illustrates the adopted system architecture and represents the data collection structure as well as the real-time E-Nose system for gas sensing and analysis.
The proposed architecture integrates a gas sensing module with a machine learning-based prediction system using a Raspberry Pi 4 board. Initially, the MQ gas sensors detect the presence of the target gas (CO) and generate an analog signal (Step 1). This analog output is fed into the MCP3008 analog-to-digital converter (ADC), which converts it into a digital signal (Step 2). The digitized data is then acquired by the Raspberry Pi (Step 3) and stored in a CSV file (Step 4). Subsequently, the stored data undergoes normalization and is passed to a pre-trained machine learning classifier (Step 5). Real-time gas detection and classification are performed with the help of the classifier, which is deployed with the help of a pickle file that is serially packaged (Step 6). The prediction of gases (Step 7), which is done by the trained model, refers to the detection of hazardous gas concentrations, including carbon monoxide (CO). This framework facilitates the acquisition of data as well as the intelligent prediction of the level of gas concentration in an embedded real-time setting. On the one hand, sensor arrays and signature recognition present great benefits to intelligent sensing systems. A sensor array consists of a number of gas sensors with different sensitivities so that it is possible to detect multiple gases at once and enhance the accuracy and selectivity. This arrangement can be cross-sensitivity-compensated, redundant, and fault-tolerant so that the performance remains reliable even when individual sensors are faulty. The resulting data are multi-dimensional, which provides rich data for feeding the sophisticated feature extraction. Using machine learning, signature recognition methods with these patterns of signals are used to identify individual gas signatures. These methods maximize reductions in noise, permit real-time adaptive learning and facilitate real-time decision-making. When used together, sensor arrays and signature recognition enable powerful, cost-efficient applications in complex systems, including air quality monitoring systems and industrial safety and smart detectors, with cheaper, highly specific sensors, yet with a high classification accuracy and responsiveness.
This article introduces the Virtual Sensor-Augmented Embedded Intelligence-based E-Nose design and architecture, which integrates both virtual sensors and embedded intelligence to gather and interpret information from different MQ cross-selective gas sensors. This system relies on the best machine learning (ML) algorithms, through which the sensor data is assessed and interpreted to provide precise and instant calculations of the carbon monoxide (CO) level. The technology is an improved way to mitigate the failures of traditional methods based on single-point sensors or threshold alarms and takes into account the changes in CO concentrations due to such factors as vehicle size, ventilation, and traffic conditions. The originality of the article concerning the Virtual Sensor-Augmented Embedded Intelligence-based novel E-Nose architecture for real-time in-vehicle CO estimation is based on a number of essential points as follows: the combination of the virtual sensors and the embedded systems, the sophisticated algorithm for data processing, dynamic counterchecks of CO variations, the primary emphasis on the safety and well-being of the passengers, and the development of the sustainable urban environment. The research presented in this paper focuses on the experimental setup in a real-time environment, data collection techniques, data analysis techniques, embedded artificial intelligence (EAI) and relevant findings of the in-vehicle CO concentration monitor and virtual sensors. Besides the discussion on CO gas monitoring, which is considered a silent killer, this study gives valuable information concerning the practical applicability of the sensor. The experimental strategy, data management, analysis methods, findings, and conclusion are well explained with some recommendations for further studies and scope expansions.

4. Experimental Setup: Hardware and Real-Time Scenario

4.1. Hardware Configuration for Data Collection

The proposed system circuit board is a connection of eight gas sensors, an MCP3008 analog-to-digital converter, and a Raspberry Pi. The analog outputs of the gas sensors are then linked to the analog inputs of the MCP3008 and the digital outputs of the MCP3008 are linked to the GIO pins of the Raspberry Pi. The circuit guarantees proper reading of data from the gas sensors as well as allows for processing on the Raspberry Pi. Their utilization requires appropriate power supplies and decoupling capacitors to work well even during power disturbances. All in all, the circuit diagram depicts the connections and parts that will be needed in the gas sensor system; Figure 2 depicts the hardware design as well as the schematic layout for data collection. Table 1 outlines the gas sensor elements used in the proposed E-Nose system and their target analytes.
Figure 2. Multi-sensor E-Nose hardware design. The hardware architecture of the multi-sensor E-Nose system features the connection of eight MQ-series gas sensors to an MCP3008 ADC and Raspberry Pi 4B through SPI to obtain real-time gas data.
Table 1. Gas sensor elements and their target analytes used in the proposed E-Nose system.
Figure 2 describes how to connect and interface eight MQ cross-selective gas sensors (MQ2, MQ3, MQ8, MQ4, MQ5, MQ7, MQ135, and MQ6) to a Raspberry Pi 4 to have a complete gas monitoring system. The aim is to measure several gases at once, and the circuit description presents the interconnection between the gaseous sensors and the Raspberry Pi 4. The Raspberry Pi 4B is used as the primary control board which offers controlling capabilities and processing power. The circuit contains voltage regulation and stability components of power supply, resistors, etc. The gas sensors are wired together to the relevant Gaussian pipelines on the Raspberry Pi 4B version, in accordance with the specifications suggested in the diagram. Other factors encompass the choice of a proper power source, conditioning of the signal when required, and the programming of the Raspberry Pi 4B to acquire data. With the help of the circuit scheme and appropriate connections, it is possible to have an effective gas monitoring system, which will help to detect and analyze gases properly. A stratified split was used to separate the dataset into training and testing phases in order to have an equal representation of each concentration level. Also, k-fold cross-validation (5) was used to test the model’s robustness and reduce overfitting.

4.2. Environmental Conditions of the Used MQ Sensor

The MQ-series gas sensors used in the suggested E-Nose system have the technical features that are outlined in Table 2, Table 3 and Table 4. These tables present key operational parameters, including detection range, sensitivity, response/recovery times, heater requirements, drift behavior, and sensitivity characteristics. As can be noted, the range of target gases that the selected sensors detect is quite impressive; combustible gases (MQ-2, MQ-5, MQ-6), alcohol vapors (MQ-3), methane (MQ-4), carbon monoxide (MQ-7), hydrogen (MQ-8), and general air pollutants (MQ-135) are all included, which allows us to achieve a comprehensive gas sensing system. Despite moderate to high levels of drift and cross-sensitivity in individual sensors, they are appropriately used in a multi-sensor array structure to produce unique response patterns to be used in pattern recognition-based classification. The drift behavior and sensitivity are also included to enhance the analysis of robustness and reliability of the sensing system in real-life operating conditions.
Table 2. Technical characteristics of MQ-series gas sensors (Part 1: MQ2–MQ5) used in the proposed E-Nose system.
Table 3. Technical characteristics of MQ-series gas sensors (Part 2: MQ6–MQ135) used in the proposed E-Nose system.
Table 4. Operating temperature and humidity range of MQ-series gas sensors used in the proposed system.

4.3. Data Collection

The purpose of the flowchart is to illustrate the process of acquiring data from a gas sensor connected to an MCP3008 analog-to-digital converter and subsequently saving the data to a CSV file using a Raspberry Pi. The flowchart consists of several steps, each representing a specific task or action in the data acquisition process. Figure 1 provides a clear and visual representation of the steps involved in acquiring data from a gas sensor, using an MCP3008 to interface with a Raspberry Pi, and saving the data to a CSV file. It highlights the sequential order of tasks and allows for easy understanding and implementation of the data acquisition process. Traditionally, the use of artificial intelligence and machine learning has been limited to high-end computing machines; however, the use of the Internet of Things and edge computing has rapidly increased. However, the computing power of these devices is not limited, and they are also capable of performing very high-level processing tasks. Furthermore, if we switch to something with more computational capability, such as the Raspberry Pi, the cost of consumption and deployment in multiple locations will be prohibitively expensive. Using the cloud for categorization activities reduces the cost and convenience for the user, simplifies hardware deployment, and ensures that all the data collected comes from the Raspberry Pi. We then apply our algorithm to it. In Figure 3a, a total of six CO concentration measurements were recorded at regular intervals. This sampling approach allowed for sufficient time for the gas sensor to stabilize and provide accurate readings. Figure 3b depicts the system architecture for data acquisition only. It is important to note that the six CO concentration levels represent reference exposure conditions rather than individual samples. For each concentration level, continuous time-series data were acquired from all eight MQ sensors over extended durations, capturing both transient and steady-state responses.
Figure 3. (a) CO container of 6l (b) injecting CO to the container.

4.4. Dataset Description

The experimental dataset was collected using the proposed embedded E-Nose system comprising eight MQ-series gas sensors (MQ2, MQ3, MQ4, MQ5, MQ6, MQ7, MQ8, MQ135). The dataset captures sensor responses corresponding to different controlled CO concentration levels. There are 2484 samples in total and 8 sensor readings. The target variable is CO concentration class (categorical + numeric encoding); the sensors used are MQ2, MQ3, MQ4, MQ5, MQ6, MQ7, MQ8, and MQ135. Every sample is associated with a steady-state sensor response that was captured inside the sampling chamber under carefully regulated exposure circumstances. A dataset summary is outlined in Table 5.
Table 5. Summary of the acquired E-Nose dataset showing the number of samples, feature composition, sensor type, classification targets, and sampling characteristics. The dataset consists of multi-sensor responses from MQ-series MOS sensors under controlled CO exposure conditions.

4.5. Schematic Layout of the Proposed System

The suggested schematic circuit board is intended to combine eight MQ-series gas sensors and an MCP3008 ADC with connecting circuit boards in a small and noise-reduced format, shown in Figure 2. The sensor array is laid across one edge of the PCB to ensure uniform gas exposure, and the analog output trace of each sensor is traced to the MCP3008 input channels separately with a short and independent route to reduce cross-talk and noise interference. The MCP3008 is positioned in the middle so that routing is minimized and so that the length of trace between sensors is also equal. The communication lines of the SPI (MISO, MOSI, SCLK, CS) are set out of the ADC to a special header to connect the Raspberry Pi to the GPIO interface. The sensor signals are grounded on a separate analog ground plane and are not connected to the digital ground to enhance the accuracy of the ADC. The regulation of power (5 V to sensors and 3.3 V logic to MCP3008) is done using on-board voltage conditioning circuits, and decoupling capacitors were placed close to each sensor and the ADC to provide stable operation. The architecture of this PCB leads to better signal integrity and scalability, and is well-suited for real-time embedded gas sensing applications.

4.6. Heatmap and Histogram

The heatmap of correlation shows the pairwise positive correlations between the MQ-series sensors and the target CO concentration, and the sensors of MQ7, MQ4, and MQ5 have strong positive correlations, which can be explained by the fact that MOS sensors are cross-sensitive. The correlation heatmap is presented in Figure 4a. Interestingly, the positive correlation between sensors such as MQ2 and MQ5 and the target variable is higher, and this implies that they will have a greater ability to predict CO concentration as opposed to MQ3, which has negative relationships with several sensors and the target. This implies that this sensor has an inverse response behavior and hence may be useful in improving the discrimination of the model, Figure 4a. In general, the fact that both strong and moderate correlations are present points at redundancy and complementary information in the sensor array, which proves that the dataset is characterized by complex and non-linear interdependence and supports the idea of employing the method of machine learning in order to extract features and classify data in the most effective way. Figure 4b shows plots demonstrating the distribution and variability values of the MQ sensor response at the different levels of CO concentration in the dataset.
Figure 4. (a) A heatmap and (b) boxplots showing correlation between visualizations of correlation with inter-sensor relationships, feature relevance to CO concentration level, and statistical characteristics of distributions of MQ-series sensor responses.

5. Data Collection and Analysis

The data collection method involved monitoring a sealed box following injection of 2 mL of CO gas into the box. Six measurements of CO concentration were taken at a predetermined time interval. The sampling technique also allowed for time for the CO sensor to stabilize and give the correct reading. The measurements of the CO concentration collected were analyzed in multiple ways, which allowed for a comprehensive analysis of the data. Statistical analysis methods were used to obtain the mean, standard deviation, and range. These statistical values were used to give an idea of the central tendency and variability of the CO concentration data. Also, visual methods like plots and histograms were used to find any possible trends, patterns, or anomalies in the measurements of CO concentration. Under PCA, the original variables that may be correlated or not are transformed to form a new set of uncorrelated variables called the principal components. These principal components are simply a linear mixture of the original variables, but sorted by the extent of variance (spread) they capture in the data. This was achieved by the PCA, as illustrated in Figure 5a. The system relies on a high-precision machine learning model previously trained on the stock of NewFresh, and it is stored in a file named NewFresh.pkl, which is loaded through the Python library of joblib or pickle. This allows for efficient new sensor data predictions, not including retraining, and scales to resource-constrained platforms, including the Raspberry Pi 4. The real and the virtual sensor data are processed on the Raspberry Pi 4. Eight MQ gas sensors (channels 0 to 7 of the MCP3008 ADC) are used to obtain sensor data, and a virtual feature is created by using mathematical combinations of physical sensor readings, as shown in Equation (1).
Virtual Sensor ( VS ) = Sensor 1 − Sensor 2 Sensor 1 + Sensor 2
Figure 5. (a) PCA plot of the dataset. (b) Trends in sensor responses to MQ-series in relation to the CO level at different times.

5.1. Sensor Trend Plot and Boxplot of Features

The response of the MQ-series sensors against time at various levels of CO concentration is represented in the sensor trend plot, where each sensor portrays dynamic characteristics such as oscillations, drift, and momentary peaks. Some sensors such as MQ4 and MQ6 have relatively fixed responses, whereas others, such as MQ2, MQ3, and MQ5, are more variable, meaning that they are highly sensitive to the variation in the gas concentration. The sensor array is able to effectively capture variations in the gas exposure over time, as observed in the steps of the target variable, which is associated with different levels of CO concentration. These time trends argue for the need for machine learning methods to provide accurate classification by indicating the complex and non-linear nature of sensor behavior, Figure 5b.
In Figure 4b the boxplot helps to show differences in the sensitivity and stability of the sensor array because it represents the distribution, dispersion, and variability of the response of the MQ-series sensors. While sensors such as MQ4 and MQ6 exhibit relatively narrow distributions, exhibiting stable baseline behavior, sensors such as MQ2 and MQ3 exhibit a larger interquartile range and increased variance, which implies that they respond quite sensitively to experimental effects of CO concentration. Instead of noise in measurements, outliers that appear in multiple sensors can be regarded as signs of a dynamic response nature and temporary exposure to gas. The variability in the spread and median values of the sensors generally shows the heterogeneous nature of the sensor array, which is beneficial in multi-dimensional feature extraction in machine learning models.
To normalize the data, zero-mean unit variance normalization (Z-score standardization) with the formula given in Equation (3) was used. This is a preprocessing process that is necessary for improving the stability and performance of machine learning models. Moreover, the methods of normalization can be used to minimize memory footprint and decrease the computational needs without a major impact on the accuracy. In Figure 6 the flow diagram depicts the deployment pipeline which includes conversion of the model followed by compression and inference, where modeling represents the initial step in the process with the subsequent steps being compaction and inference, which decompose the feature space into smaller and well-separated clusters, improving the generalization of the classifier. As seen in the PCA visualization, Figure 5a, this improved feature representation produces more compact and well-separated clusters in the feature space, which enhances classifier generalization.
Figure 6. Deployment model block diagram.

5.2. Normalized Difference Sensor Response Transformation (NDSRT)

Accurate classification of gases and odors remains a longstanding challenge. To improve classification performance, gas sensor arrays are commonly employed, as they produce distinctive signature patterns for each gas or odor sample. Rather than relying solely on these raw signatures, analyzing them within transformed hyperspaces can further enhance classification accuracy. However, existing transformation and normalization techniques often yield non-spherical and overlapping clusters, which contribute to ambiguity in classification outcomes. The NDSRT [37] generates virtual sensor responses for considered samples of gases. For taken-in gas samples, it produces simulated sensor responses. If a dataset comprises well-separated clusters from the considered gases that have shorter intra-cluster distances, the data can be categorized well. Following the suggested transformation, the obtained virtual multi-sensor responses exhibit distinctive signature patterns for the entire class of the relevant gas, regardless of the sample concentration. In contrast, these kinds of clearly defined clusters were not present in the unprocessed gas sensor responses or other well-known transformation domains like Principal Component Analysis (PCA) and other normalization methods [7]. The virtual sensor responses were used to augment the operational vectors’ dimensions. The main elements of the real sensor responses are used to create these virtual responses. As a result, two sets of data are upscaled to one dimension, as discussed in [38]. Virtual multi-sensor responses are the name given to sensor responses in this field. In this work, the Normalized Difference Sensor Response Transformation (NDSRT) analytical domain has been put forth. The NDSRT methodology presented in this study has been developed in the NCC Lab by our research group and is cited accordingly in the referenced literature [39]. The following are the steps for creating an NDSRT-based virtual multi-sensor response: Consider a gas sensor array with n elements that produces a signature response named X for each sample it detects. The responses of the ith and jth sensor elements are x i and x j , respectively, so that X = x 1 , x 2 , x 3 , … , x i , … , x j , … , x n . The NDSRT response can be calculated using the formula in Equation (2)
N D S R T = x i − x j x i + x j for all i < j
where NDSRT represents the Normalized Difference Sensor Response Transformation, x i and x j are variables or sensor responses for indices i and j, and ( i < j ) indicates that this equation holds for all pairs of i and j where i is less than j.
Although normalized difference formulations have been used in prior studies, the proposed NDSRT framework differs in its systematic application across all sensor pairs in a multi-sensor array, generating a high-dimensional virtual feature space. This transformation enhances inter-class separability and reduces intra-class variance, leading to improved classification performance compared to raw sensor responses and conventional dimensionality reduction techniques such as PCA, as shown in Figure 5a.

5.3. Zero Mean Unit Variance (ZMUV)

ZMUV normalization is an improved, useful preprocessing method [39] that can be used to normalize sensor data. It removes the scale and unit differences, helps to make equitable comparisons, and improves data analysis task performance. The ZMUV can be calculated using the formula in Equation (3). ZMUV normalization is important as it converts the sensor data into zero mean and unit variance to enhance the accuracy and reliability of the latter data analysis and modeling procedures. This type of normalization method will be used to make sure that the data of every sensor has a mean of zero and unit variance, meaning that the data can be directly compared. The resulting normalized data enhances the performance of data analysis and modeling tasks, such as clustering, classification, and regression, by providing a consistent and standardized representation.
Z M U V = Sensor Data − Mean Value of Sensor Standard Deviation
Mean Value of Sensor = ∑ i = 1 n Sensor i n
where the Mean Value of the Sensor represents the mean (average) value of the sensors as shown in Equation (4), S e n s o r i represents individual sensor readings, and n is the total number of sensors.
SD = ∑ i = 1 n ( Sensor data i − Mean Value of Sensor ) 2 n
where the SD (standard deviation) represents the standard deviation of the sensor data as shown in Equation (5). The CSV file containing data from eight sensors is transformed into data from eight real and eight virtual sensors using the NDSRT. The transformed data is then further processed to achieve zero mean unit variance. Finally, the resulting data is used to generate the desired output.

5.4. Data Analysis

After the transformation, the data is subjected to zero mean unit variance normalization. This step ensures that the data is centered around a zero mean and has a standard deviation of one. Normalizing the data in this way helps to standardize the scale and facilitates accurate comparisons and analyses. The processed data, now in zero mean unit variance form, is then used to generate the desired output. This output can be in the form of classification results, regression predictions, or any other relevant outcome based on the specific task at hand. The data processing pipeline involves transforming the initial CSV file’s eight-sensor data points into real and virtual sensor data using the NDSRT. The transformed data was then further processed to achieve zero mean unit variance. This processed data was utilized to generate the desired output, which could be utilized for various purposes such as classification, regression, or further analysis. We did four classifications, and out of these, we put our best-trained model in the hardware. Hence, from Figure 7, it is clear that data has been utilized for preprocessing and then output in real time.
Figure 7. Data transformation from first stage to final stage.
The high classification accuracy observed in this study is influenced by the controlled experimental conditions shown in Table 6, which ensure stable and noise-reduced sensor responses. While this enables effective validation of the proposed methodology, it may lead to optimistic performance estimates compared to real-world deployment scenarios.
Table 6. Accuracy of used classifier.

5.5. CO of 1 Millilitre (mL) to Parts per Million (PPM)

PPM (parts per million) is a unit of measurement, and it is important in various fields, including science, engineering, and environmental monitoring. In our case, we express the measurement of CO concentration in PPM. To convert a specific volume (1 mL) to PPM in a larger container (e.g., 6 L), the basic formula and principles involved are shown in Equation (6).
ppm = Volume of Substance ( mL ) Total Volume ( L ) × 1,000,000
where ppm represents parts per million, which is the unit of measurement. “Volume of Substance (mL)” is the volume of the substance we want to express in ppm (in this case, 1 mL initially). “Total Volume (L)” is the total volume of the mixture or container (in this case, 6 L), and multiplication by 1,000,000 is used to convert the ratio into ppm. The appropriate concentration was achieved injecting CO, using a syringe of 5 mL, into a container of 6 mL. The initial container contained only fresh air; then, we injected 2 mL as shown, and so on. We repeated the procedure 6 times to achieve the target concentration of CO in the container, and at the final stage, we measured a 1322++ PPM concentration of CO in the container. Figure 3a shows a CO container of 6 L, and the addition of CO to this container of 6 L volume is shown in Figure 3b. The PPM concentration of CO in the container is shown in Equation (7).
PPM Concentration , CO = 1 mL 6 L = 1 mL · 10 3 6 L · 10 3 · 10 3 = 166.66 PPM
The scenario we have described involves the addition of 2 mL increments of carbon monoxide (CO) to a 6-liter container, with each increment doubling the concentration. Here is how the concentrations evolve: Initial concentration: 166.67 ppm (as previously calculated); then, 2 mL of CO is added, doubling the concentration to 2 × 166.67 ppm = 333.33 ppm , and another 2 mL is added, doubling the concentration again to 2 × 333.33 ppm = 666.67 ppm , and so on. Each time we add 2 mL of CO, the concentration doubles from the previous value. This pattern will continue as long as we keep adding 2 mL increments.

5.6. Comparative Analysis with State-of-the-Art Systems

The proposed E-Nose system is compared with recent state-of-the-art approaches, as shown in Table 7. Existing systems achieve 94–96% accuracy but rely on cloud processing or optimized hardware. In contrast, the proposed method combines MQ sensor arrays with NDSRT-based virtual sensors and ensemble learning to achieve 98.59% accuracy. Its edge deployment on Raspberry Pi ensures low latency, cost-effectiveness, and improved real-time applicability in vehicular environments. Table 6 highlights the accuracy of the used classifier.
Table 7. Comparative performance analysis of the proposed E-Nose system with recent in-vehicle air quality monitoring systems.

5.7. Statistical Validation

Statistical analysis proves that sensor responses divert in a noticeable way and MQ2, MQ8 and MQ3 have a great deal of standard deviation, denoting that these sensors are sensitive to the change in CO concentration. Other sensors such as MQ4 and MQ6 on the other hand are low-baseline sensors. The skewness and large kurtosis of many of the sensors are confirmation that the data is not Gaussian and dynamic due to the fact that it represents a sensor in the real world in different conditions of exposure to the gas. Moreover, the zero-read values were associated with sensor initialization stages and were maintained to guarantee data authenticity. A statistical summary of the MQ-series sensor is outlined in Table 8.
Table 8. Statistical summary of MQ-series sensor responses, including mean, standard deviation, minimum, and maximum values.

6. Results and Discussion

The results obtained from this experiment demonstrate the effectiveness of the Virtual Sensor-Augmented Embedded Intelligence-based advanced E-Nose architecture in accurately estimating carbon monoxide (CO) concentrations in real time. Initially, when fresh air is introduced into the container, the system correctly detects and displays no presence of CO, indicating that the environment is free from any CO contamination. Next, a controlled amount of 2 mL of CO is injected into the container. The system promptly detects the presence of CO and displays a concentration of 333 ppm, accurately reflecting the introduced CO amount. Subsequently, another 2 mL of CO is added to the container, resulting in an increased concentration of 666 ppm. This trend continues as additional 2 mL increments of CO are introduced, with each increment doubling the concentration. Therefore, subsequent readings show concentrations of 999 ppm, 1332, and so on. It should be noted, though, that once the concentration goes beyond 1332 ppm, the sensor shows a constant 1332 ppm+ upon further addition of CO. This means that our range limit is 1332 ppm+. These findings reflect the effectiveness of the system in monitoring and estimating CO levels in real time to obtain useful information to control the quality of air in a limited area. The gradual growth in concentration as the CO is added in the system testifies to the sensitivity and responsiveness of the system to changes in CO concentration.
In the present experiment, we confirm the effectiveness of the Virtual Sensor-Augmented Embedded Intelligence-based E-Nose system in delivering unbiased and prompt CO concentration measurements. The results are useful in creating an effective in-vehicle CO system, which is beneficial for ensuring that passengers are safe and allows people to take the necessary proactive steps to reduce the risk posed by high CO levels. Confusion matrices of Decision Tree, Gradient Boosting, KNN and Random Forest classifiers indicate that they have high classification and low misclassification rates with respect to CO concentration levels, Figure 8.
Figure 8. Confusion Matrix (CM) of (a) Decision Tree, (b) Gradient Boost, (c) K-Nearest Neighbor, and (d) Random Forest.
To begin with, the virtual sensor algorithms can be narrowed down to make the estimation of the CO concentration more accurate and reliable. Sensor data can be enhanced with additional machine learning techniques, such as deep learning algorithms, to extract more useful information out of it and to make the virtual sensor more competent in terms of prediction. Second, the system could have additional gas sensors, and it would be possible to monitor more harmful gases, such as nitrogen dioxide NO2 or volatile organic compounds (VOCs). This would make it a more holistic in-vehicle air quality monitoring system. Thirdly, the platform should have real-time alerting and notifications, which would allow for the issuance of instant alerts to vehicle occupants and the corresponding authorities in case of high CO levels. This would help in taking action on time to address risks and guarantee safety to the passengers. The other way of improving the system is through integrating the E-Nose architecture into vehicle control systems. High CO levels would be automatically sensed by the system, which would then engage ventilation systems or open roll down windows to increase the air circulation in the room and minimize CO exposure. The ability to process data and log results can be incorporated to document the CO concentration with time. This data could be analyzed to identify patterns, trends, and potential sources of CO emissions, enabling preventive maintenance, emission control, and optimization of the in-vehicle air quality management system.

Discussion: System-Level Integration Perspective

Recent developments in gas sensing research have shifted more towards system-level integration, in which sensing, signal processing, and intelligence are co-architectured on common platforms. Recent research, such as that in ACS Sensors [36], is moving towards the integration of small sensor arrays into compact, integrated sensing systems with on-chip processing, adaptive calibration, and real-time inference. Unlike hardware-oriented integration models, like MEMS-based miniaturized sensors and system-on-chip (SoC) architectures, the proposed E-Nose framework will take a system-level approach to integration using software-defined sensing. In particular, combined with edge-deployed machine learning models, cross-sensitive MQ sensor arrays integrated with virtual sensor augmentation and the Normalized Difference Sensor Response Transformation (NDSRT) algorithm can robustly and adaptively estimate gases without involving expensive specialized hardware.
This architecture is a hybrid integration paradigm since physical sensing, virtual sensing, and embedded intelligence are united. Virtual sensors are efficient to boost feature dimensionality and counter cross-sensitivity and drift, whereas real-time inference with embedded machine learning can be applied in resource-constrained settings. The proposed solution is a scalable low-cost and flexible alternative to the present-day integrated gas sensing systems in terms of financial and space limitations and when applied to the automotive and IoT market. Therefore, this work is relevant in the changing face of intelligent gas sensing by showing that system-level integration based on algorithmic augmentation and integrated intelligence can provide performance equivalent to more complicated hardware-integrated systems. Also, we have integrated and proven recent developments in integrated gas sensing systems, such as [36,40]. Furthermore, recent developments in integrated gas sensing systems are incorporated to appropriately position this work within the current state of the art.
These considerations also illustrate how the proposed system can transition from a controlled experimental setup to a scalable, embedded, and intelligent in-vehicle sensing platform.
The suggested multi-sensor E-Nose system exhibits high potential for real system-level application in actual in-vehicle situations. At the time of evaluation, conditions were controlled, but the architecture is scalable for use in embedded platforms and edge intelligence as a real-time processing method. In the cabin, dynamic conditions of airflow, temperature, humidity, and ventilation cause sensor responses and require strong measures such as multi-sensor fusion, adaptive calibration, and drift compensation. The new developments in integrated gas sensing focus on compact, smart designs with inference on the device part, which can be integrated into the proposed framework to improve reliability. Moreover, they can be integrated into ECUs, wireless modules, and IoT-based systems, allowing for constant monitoring and decision-making in real time that can be used in safety-related tasks like in-cabin air quality evaluation and CO exposure detection.

7. Limitations and Future Work

In spite of the bright prognosis of the presented virtual sensor-augmented E-Nose structure, a number of limitations should be noted. First, the experimental data was obtained in a controlled setting and in a closed chamber of 6 L, with a limited number of discrete concentrations of CO, which constrained the variety of data and statistical resilience of modeling machine learning methods and thus their general applicability. Second, the system does not completely recreate the in-vehicle conditions, as dynamic conditions such as airflow, temperature, humidity, ventilation, and multi-source emissions play an important part in gas dispersion and sensor output. Third, cross-sensitivity and drift are the most common features of MQ-series metal-oxide sensors, and these may affect the long-term stability and usability of MQ-series sensors in the real world. Moreover, the current evaluation is based on both training and test splits, but it fails to clearly delineate the study’s limitations. of both time and source-wise information and potentially providing over-optimistic estimates of the performance. The virtual sensor formulation is excellent; it requires pairwise transformations, and higher-order non-linear sensor interactions may not be present. Future studies will investigate the collection of large and real-world in-vehicle datasets in a broad variety of driving and environmental conditions; more powerful deep learning and domain adaptation techniques will be used to improve the generalization process, and other types of environmental sensors (e.g., temperature and humidity) will be included in for context-sensitive calibration. In addition, effective validation schemes such as cross-validation leaving out a vehicle will be employed, as well as drift compensation and online learning. Additional benefits to the applicability and scalability of the system, with regard to multi-gas monitoring, real-time adaptive control integration (ex: HVAC actuation), and integration in connected vehicle ecosystems, will be gained by further development. Studies in the future will be based on testing the suggested system in real car situations, where airflow, temperature, and humidity may change. Also, the incorporation of embedded AI models, adaptive calibration methods, and IoT-based communication will be discussed to allow for deployment in real time and on a large scale.

8. Conclusions

Virtual sensors and embedded intelligence are utilized in the Virtual Sensor-Augmented Embedded Intelligence-based E-Nose architecture, which collects and processes data from several gas sensors to obtain a complete picture of the CO levels in a vehicle. The embedded intelligence applies complex algorithms to process the sensor data in order to accurately estimate the level of CO in the air in real time. Considering the urgency of reporting the level of CO in cars, the Virtual Sensor-Enhanced Embedded Intelligence-based advanced E-Nose architecture is an innovative solution. This paper explores the possible integration with vehicle control systems and optimizes the virtual sensor techniques and the development and validation of the proposed architecture. The predicted outcomes are ensuring passenger safety and well-being as well as making progress in monitoring air quality in vehicles. This technology is superior to older technologies, which used single-point sensors or threshold-based alarms which do not necessarily give a true indication of actual CO levels because of factors such as vehicle size, ventilation, and traffic. The future of this architecture in the form of real-time in-vehicle estimation of CO concentration looks exciting, and its inclusion in smart city infrastructures may lead to a network of connected vehicles and environmental monitoring devices which can help collect and share real-time data and assist in making superior urban planning, traffic control, and policy decisions. It has also been revealed that the proposed system has good potential to be integrated on the system level into actual vehicular scenarios, with proposed future research being on the implementation of the system at the embedded level, with environmental compensation, in real time.
The suggested architecture is in line with the future trends in integrating gas sensors at the system level, virtual feature augmentation, and embedded intelligence in a single architecture. Although these are encouraging findings, the controlled chamber-based experiments used in the present study cannot fully reflect the true dynamics of the actual in-vehicle airflow environment or changes in temperature, humidity, and ventilation effects. The next steps of this work should be related to the attempt to prove the suggested system in the real conditions of a vehicle in order to evaluate its sturdiness and generalization under scaled working conditions.

Author Contributions

D.K., N.S.R., A.K.R. and A.M.: methodology, validation, formal analysis, investigation, and preparation of the original draft. D.K. and A.K.R. were in charge of the conceptualization, methodology, validation, formal analysis, investigation and development of the original draft. The original document was written by A.M., N.S.R. and R.S., and the document was reviewed and amended and finally underwent a formal review of analysis. All authors have read and agreed to the published version of the manuscript.

Funding

This study was sponsored by under the under Grant No. IS/ST/EC-13-14/02, the I-DAPT HUB Foundation, IIT (BHU), Varanasi, India, under Grant R&D/SA/I-DAPT/IIT(BHU)/ECE/21-22/02/290.

Data Availability Statement

The data supporting the findings of this investigation are accessible from the corresponding author upon reasonable request.

Acknowledgments

We acknowledge the administrative, technical, and financial support received in parts from NCC LAB, Department of Electronics Engineering, IIT (BHU), Varanasi.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
AAAAmerican Automobile Association
CNGCompressed Natural Gas
MLMachine Learning
DTDecision Tree
HVACHeating, Ventilation, and Air Conditioning
GPIOGeneral Purpose Input Output
PPMParts Per Million
PCAPrinciple Component Analysis
RFRandom Forest
SDStandard Deviation
VSRVirtual Sensor Response
VOCsVolatile Organic Compounds
NO2Nitrogen Dioxide
COCarbon Monoxide
PEMSPortable Emission Measurement System
NDRSTNormalized Difference Sensor Response Transformation
OBDOn-Board Diagnostics
ZMUVZero Mean Unit Variance

References

  1. Tefft, B.C. Prevalence of motor vehicle crashes involving drowsy drivers, United States, 1999–2008. Accid. Anal. Prev. 2012, 45, 180–186. [Google Scholar] [CrossRef] [Scilit]
  2. Ministry of Transport Malaysia. Transport Statistics Malaysia. In Statistik Pengangkutan Malaysia; Ministry of Transport Malaysia: Putrajaya, Malaysia, 2017. [Google Scholar]
  3. Grady, M.L.; Jung, H.; chul Kim, Y.; Park, J.K.; Lee, B.C. Vehicle Cabin Air Quality with Fractional Air Recirculation; Technical Report, SAE Technical Paper; University of California: Riverside, CA, USA, 2013. [Google Scholar]
  4. Thirumal, P.; Amirthagadeswaran, K.; Jayabal, S. Optimization of IAQ characteristics of an air-conditioned car using GRA and RSM. J. Mech. Sci. Technol. 2014, 28, 1899–1907. [Google Scholar] [CrossRef] [Scilit]
  5. Ponticelli, L.; Barbaro, M.; Mandragora, G.; Pagano, G.; Torres, G.S. Comparison of KF-based vehicle sideslip estimation logics with increasing complexity for a passenger car. Sensors 2024, 24, 4846. [Google Scholar] [CrossRef] [Scilit]
  6. Botticini, S.; Comini, E.; Dello Iacono, S.; Flammini, A.; Gaioni, L.; Galliani, A.; Ghislotti, L.; Lazzaroni, P.; Re, V.; Sisinni, E.; et al. Index air quality monitoring for light and active mobility. Sensors 2024, 24, 3170. [Google Scholar] [CrossRef] [Scilit]
  7. Rizvi, S.H.A.; Agrawal, P.; Batra, S.; Nidhi, N.; Singh, V. Assessing urban heat island intensity and emissions with compressed natural gas in non-commercial vehicles. Urban Clim. 2023, 48, 101421. [Google Scholar] [CrossRef] [Scilit]
  8. Shi, Q.; Zheng, B.; Zheng, Y.; Tong, D.; Liu, Y.; Ma, H.; Hong, C.; Geng, G.; Guan, D.; He, K.; et al. Co-benefits of CO2 emission reduction from China’s clean air actions between 2013–2020. Nat. Commun. 2022, 13, 5061. [Google Scholar] [CrossRef] [Scilit]
  9. Goh, C.C.; Kamarudin, L.M.; Zakaria, A.; Nishizaki, H.; Ramli, N.; Mao, X.; Syed Zakaria, S.M.M.; Kanagaraj, E.; Abdull Sukor, A.S.; Elham, M.F. Real-time in-vehicle air quality monitoring system using machine learning prediction algorithm. Sensors 2021, 21, 4956. [Google Scholar] [CrossRef] [Scilit]
  10. Luo, Z.; Wang, Y.; Lv, Z.; He, T.; Zhao, J.; Wang, Y.; Gao, F.; Zhang, Z.; Liu, H. Impacts of vehicle emission on air quality and human health in China. Sci. Total. Environ. 2022, 813, 152655. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Hwang, H.; Choi, S.R.; Lee, J.Y. Evaluation of roadside air quality using deep learning models after the application of the diesel vehicle policy (Euro 6). Sci. Rep. 2022, 12, 20769. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Andrade, P.; Silva, I.; Silva, M.; Flores, T.; Cassiano, J.; Costa, D.G. A tinyml soft-sensor approach for low-cost detection and monitoring of vehicular emissions. Sensors 2022, 22, 3838. [Google Scholar] [CrossRef] [Scilit]
  13. Srivastava, S.; Chaudhri, S.N.; Rajput, N.S.; Mishra, A. A novel data-driven technique to produce multi-sensor virtual responses for gas sensor array-based electronic noses. J. Electr. Eng. 2023, 74, 102–108. [Google Scholar] [CrossRef] [Scilit]
  14. Chung, J.j.; Kim, H.J. An automobile environment detection system based on deep neural network and its implementation using IoT-enabled in-vehicle air quality sensors. Sustainability 2020, 12, 2475. [Google Scholar] [CrossRef] [Scilit]
  15. Mishra, A.; Lee, S.; Kim, D.; Kim, S. In-cabin monitoring system for autonomous vehicles. Sensors 2022, 22, 4360. [Google Scholar] [CrossRef] [Scilit]
  16. Zhu, X.H.; He, H.D.; Lu, K.F.; Peng, Z.R.; Gao, H.O. Characterizing carbon emissions from China V and China VI gasoline vehicles based on portable emission measurement systems. J. Clean. Prod. 2022, 378, 134458. [Google Scholar] [CrossRef] [Scilit]
  17. Chaudhri, S.N.; Rajput, N.S.; Alsamhi, S.H.; Shvetsov, A.V.; Almalki, F.A. Zero-padding and spatial augmentation-based gas sensor node optimization approach in resource-constrained 6G-IoT paradigm. Sensors 2022, 22, 3039. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Liu, T.; Guo, L.; Wang, M.; Su, C.; Wang, D.; Dong, H.; Chen, J.; Wu, W. Review on algorithm design in electronic noses: Challenges, status, and trends. Intell. Comput. 2023, 2, 12. [Google Scholar] [CrossRef] [Scilit]
  19. Zhu, S.; Yu, T.; Xu, T.; Chen, H.; Dustdar, S.; Gigan, S.; Gunduz, D.; Hossain, E.; Jin, Y.; Lin, F.; et al. Intelligent computing: The latest advances, challenges, and future. Intell. Comput. 2023, 2, 6. [Google Scholar] [CrossRef] [Scilit]
  20. Wijaya, D.R.; Afianti, F. Information-theoretic ensemble feature selection with multi-stage aggregation for sensor array optimization. IEEE Sens. J. 2021, 21, 476–489. [Google Scholar] [CrossRef] [Scilit]
  21. Sharma, C.; Choudhury, R.; Sarma, U. Sensor array optimization to design and develop an electronic nose system for the detection of water stress in Khasi Mandarin orange. J. Circuits Syst. Comput. 2022, 31, 2250172. [Google Scholar] [CrossRef] [Scilit]
  22. Zhai, Y.; Huang, J.; Liu, C.; Liu, Y. Research on refrigerator electronic nose monitoring system based on Raspberry Pi. In Proceedings of the 2nd International Conference on Electrical Engineering and Control Science (IC2ECS), Nanjing, China, 16–18 December 2022; pp. 877–880. [Google Scholar] [CrossRef] [Scilit]
  23. Shahid, A.; Fuentes, S.; Gonzalez Viejo, C.; Widdicombe, B.; Unnithan, R.R. Automated Assessment of Green Infrastructure Using E-nose, Integrated Visible-Thermal Cameras and Computer Vision Algorithms. Sensors 2025, 25, 6812. [Google Scholar] [CrossRef] [Scilit]
  24. Mathe, S.E.; Kondaveeti, H.K.; Vappangi, S.; Vanambathina, S.D.; Kumaravelu, N.K. A comprehensive review on applications of Raspberry Pi. Comput. Sci. Rev. 2024, 52, 100636. [Google Scholar] [CrossRef] [Scilit]
  25. Misbah; Astutik, R.P.; Eliyani; Winarno, H.A.; Muklish, A.; Andesta, D. Communication system on wireless sensor networks using Raspberry Pi and Arduino for monitoring gas of air pollution. In Proceedings of the International Seminar on Intelligent Technology and Its Applications (ISITIA), Bali, Indonesia, 30–31 August 2018; pp. 27–32. [Google Scholar] [CrossRef] [Scilit]
  26. Samourkasidis, A.; Athanasiadis, I.N. A miniature data repository on a Raspberry Pi. Electronics 2017, 6, 1. [Google Scholar] [CrossRef] [Scilit]
  27. Wicaksono, M.F.; Rahmatya, M.D. Server security and air quality monitoring system using Raspberry Pi 4 and Telegram. J. Eng. Sci. Technol. 2024, 19, 1156–1170. [Google Scholar]
  28. Napolitano, D.G.; Ruffini, M.; Stefanelli, R.; Adiletta, G.; Fichera, G.; Timpone, F. Four-Wheeled Vehicle Sideslip Angle Estimation: A Machine Learning-Based Technique for Real-Time Virtual Sensor Development. Appl. Sci. 2024, 14, 1036. [Google Scholar] [CrossRef] [Scilit]
  29. Chang, I.S.; Byun, S.W.; Lim, T.B.; Park, G.M. A study on E-nose system in terms of the learning efficiency and accuracy of boosting approaches. Sensors 2024, 24, 302. [Google Scholar] [CrossRef] [Scilit]
  30. Hernández-Alcántara, D.; Tudón-Martínez, J.C.; Amézquita-Brooks, L.; Vivas-López, C.A.; Morales-Menéndez, R. Modeling, diagnosis and estimation of actuator faults in vehicle suspensions. Control Eng. Pract. 2016, 49, 173–186. [Google Scholar] [CrossRef] [Scilit]
  31. Silva, D.R.; Oliveira, G.M.; Silva, I.; Ferrari, P.; Sisinni, E. Latency evaluation for MQTT and WebSocket Protocols: An Industry 4.0 perspective. In Proceedings of the 2018 IEEE Symposium on Computers and Communications (ISCC), Natal, Brazil, 25–28 June 2018; IEEE: Piscataway, NJ, USA, 2018; pp. 01233–01238. [Google Scholar]
  32. Silva, M.; Vieira, E.; Signoretti, G.; Silva, I.; Silva, D.; Ferrari, P. A customer feedback platform for vehicle manufacturing compliant with industry 4.0 vision. Sensors 2018, 18, 3298. [Google Scholar] [CrossRef] [Scilit]
  33. Batra, N.; Kaur, J.; Batra, N. SmartCOdetect: An Automated Car Window Opening System on Detection of Carbon Monoxide. Int. J. Veh. Struct. Syst. 2020, 12, 398–404. [Google Scholar] [CrossRef] [Scilit]
  34. Byard, R.W. Carbon monoxide—The silent killer. Forensic Sci. Med. Pathol. 2019, 15, 1–2. [Google Scholar] [CrossRef] [Scilit]
  35. Dubinin, D.; Avetisyan, V.; Shevchenko, S.; Hovalenkov, S.; Beliuchenko, D.; Maksymov, A.; Cherkashyn, O. Investigation of the effect of carbon monoxide on people in case of fire in a building. Sigur. Časopis Sigur. Radn. Životnoj Okolini 2020, 62, 347–357. [Google Scholar] [CrossRef] [Scilit]
  36. Gao, M.; Zhang, B.; Du, X.; Yang, X.; Zhai, C.; Chen, C.; Zhang, Z.; Zhao, W. InSe-based sensors and related sensing systems for NO2 gas/temperature monitoring. ACS Sens. 2025, 10, 7124–7133. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Mishra, A.; Rajput, N.; Han, G. NDSRT: An efficient virtual multi-sensor response transformation for classification of gases/odors. IEEE Sens. J. 2017, 17, 3416–3421. [Google Scholar] [CrossRef] [Scilit]
  38. Chaudhri, S.N.; Rajput, N.S.; Mishra, A. A novel principal component-based virtual sensor approach for efficient classification of gases/odors. J. Electr. Eng. 2022, 73, 108–115. [Google Scholar] [CrossRef] [Scilit]
  39. Montminy, D.P.; Baldwin, R.O.; Temple, M.A.; Laspe, E.D. Improving cross-device attacks using zero-mean unit-variance normalization. J. Cryptogr. Eng. 2013, 3, 99–110. [Google Scholar] [CrossRef] [Scilit]
  40. Li, S.; Tang, W.; Chen, S.; Si, Y.; Liu, R.; Guo, X. Flexible organic polymer gas sensor and system integration for smart packaging. Adv. Sens. Res. 2023, 2, 2300030. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.