Abstract

Background: Autogenous dentin obtained from extracted teeth is increasingly used as a particulate bone substitute for guided bone regeneration, but the graft must be reliably decontaminated before implantation. This in vitro study compared the decontaminating efficacy of cold atmospheric plasma (CAP) with that of the manufacturer’s chemical dentin cleanser on dentin granules colonized with Enterococcus faecalis. Materials and methods: Ten freshly extracted human wisdom teeth were processed into particulate dentin with a Smart Dentin Grinder and divided into eight subgroups per tooth. Seven subgroups were colonized with E. faecalis for six days; one served as a sterile negative control. Colonized granules, kept covered with 1 mL PBS to prevent desiccation, were treated with CAP for 1, 3, 5, and 10 min, and with the chemical dentin cleanser for 5 or 10 min. Decontamination was assessed by colony-forming unit (CFU) counts and live/dead fluorescence staining. Results: All decontamination protocols reduced the mean bacterial load relative to the untreated positive control (mean 430; all counts are given per 100 µL of the 10−4 dilution, corresponding to 4.3 × 107 CFU/mL); after correction for multiple comparisons, this reduction was statistically significant for 5 min of CAP (p = 0.043) and for both cleanser protocols (p ≤ 0.003), but not for 1, 3, or 10 min of CAP (p = 0.594, 0.055, and 0.594). Among the CAP intervals, the lowest mean count was observed after 5 min (253), which was significantly lower than after 1 min (363; p = 0.001); 10 min did not yield a lower mean count (316; p = 0.594). The chemical dentin cleanser produced the numerically lowest counts (166 after 5 min; 100 after 10 min). After correction for multiple comparisons, 5 min of CAP did not differ significantly from the 5 min (mean paired difference 87, 95% CI −32 to 205; p = 0.594) or the 10 min cleanser protocol (153, 95% CI 27 to 279; p = 0.136), although the unadjusted confidence interval of the latter difference excluded zero. Viable bacteria were recovered after every treatment. Conclusions: Both CAP and the chemical dentin cleanser reduced E. faecalis on autogenous dentin granules. The cleanser groups showed the lowest observed mean counts, and 5 min was the CAP interval with the lowest observed mean count. After correction for multiple comparisons, no statistically significant difference was detected between this CAP protocol and the cleanser, although the 10 min cleanser tended to leave fewer viable bacteria; the study was not designed to demonstrate equivalence, and neither method produced culture-negative granules. CAP, which acts without an added liquid disinfectant, warrants further investigation, but equivalent efficacy and clinical suitability have not been established.

1. Introduction

Dental implants have become a cornerstone of prosthetic rehabilitation for partially and fully edentulous patients, and their long-term success depends on sufficient three-dimensional host bone volume. After tooth extraction, however, the alveolar ridge undergoes pronounced remodeling and loses a substantial proportion of its original width and height within the first months of healing [1]. Bone augmentation is therefore frequently required to allow a prosthetically driven implant position, and guided bone regeneration (GBR) has become the most widely used augmentation technique. A broad spectrum of grafting materials is available, ranging from autogenous bone to allogeneic, xenogeneic, and alloplastic substitutes. Each non-autogenous option has limitations, including the absence of vital cells, a predominantly osteoconductive mode of action, a residual, albeit low, risk of disease transmission, and ethical or religious reservations. Harvesting autogenous bone, in turn, requires a second surgical site with associated donor-site morbidity and unpredictable resorption.
Against this background, autogenous dentin prepared from the patient’s own extracted teeth has emerged as an attractive alternative. Dentin shares much of its composition with alveolar bone, consisting largely of hydroxyapatite together with a type I collagen matrix and non-collagenous proteins, including bone morphogenetic proteins that confer osteoinductive potential [2]. Using a chairside grinding device, an extracted tooth can be converted within minutes into particulate dentin that is available in excess of the original root volume. Physicochemical analyses of ground human teeth have shown that the composition of the resulting powder does not differ substantially between tooth types, supporting its general suitability as an augmentation material provided it is free of micro-organisms [3]. Clinical and histological studies have shown that autogenous (partially) demineralized dentin matrix supports new bone formation by osteoinduction and osteoconduction and performs comparably to established bone substitutes in socket preservation, ridge augmentation, and GBR [4,5,6]. Because the graft is autologous, it avoids immunological reactions and a second donor site, exploits material that is otherwise discarded as clinical waste, and is cost-effective.
A prerequisite for the safe use of tooth-derived grafts is reliable decontamination. Extracted teeth affected by caries or periodontal or endodontic disease may carry a considerable bacterial load, with organisms residing deep within the dentinal tubules. Grafting insufficiently decontaminated material risks postoperative infection and graft failure. Clinical data support this concern: in a randomized trial in chronically infected extraction sockets, supplementing an autogenous demineralized dentin graft with metronidazole increased the proportion of mineralized bone after six months from 30.2% to 55.0% [7]. To challenge decontamination protocols under demanding conditions, Enterococcus faecalis is a well-established model organism: a facultatively anaerobic, Gram-positive species notorious for its persistence in the root canal system and its ability to invade dentinal tubules and form biofilms, and its marked resistance to a range of antiseptics [8].
Cold atmospheric plasma (CAP) has attracted increasing interest as a non-thermal means of surface decontamination that does not require an added liquid disinfectant in medicine and dentistry. CAP is a partially ionized gas that operates below 40 °C and generates reactive oxygen and nitrogen species, which inactivate micro-organisms by oxidative damage to cell membranes, DNA and RNA, while remaining tolerable for host tissues [9,10]. A systematic review has confirmed its antimicrobial activity against a broad range of dental pathogens [11]. In implant dentistry, CAP reduces the bacterial load on titanium surfaces and on collagen and polytetrafluoroethylene membranes used for GBR [12,13], and can match chemical antiseptics such as chlorhexidine in biofilm reduction [14]. Beyond its antimicrobial action, CAP favorably modifies biomaterial surfaces and supports cell attachment and proliferation [15]. Whether these advantages translate to a porous, particulate substrate such as autogenous dentin granules, where reactive species must reach bacteria located between particles and potentially within dentinal tubules, has not yet been investigated.
The aim of the present in vitro study was therefore to compare the decontaminating efficacy of CAP, applied for 1, 3, 5 and 10 min, with that of the manufacturer’s chemical dentin cleanser, applied for 5 and 10 min, on autogenous dentin granules colonized with E. faecalis. Decontamination was quantified by CFU counts and corroborated by live/dead fluorescence staining. The null hypothesis was that CAP and the chemical dentin cleanser do not differ in their decontaminating efficacy.

2. Materials and Methods

2.1. Study Design

This experimental in vitro study was conducted using extracted human wisdom teeth. The teeth were obtained from patients of the Department of Oral and Maxillofacial Surgery at the University Hospital Schleswig-Holstein, Kiel Campus. An overview of the complete experimental protocol is given in Figure 1. The ethics committee approved the study (Medical Faculty of the Christian Albrechts University, D 441/25), and the study was conducted in accordance with the Declaration of Helsinki. The subgroups were not processed in random order. Within each tooth, treatment always started with the longest exposure (10 min of CAP) and proceeded to the shorter intervals. Colony counting was not blinded to group allocation.
Figure 1. Flow chart of the experimental protocol, from sample preparation and bacterial contamination through decontamination and bacterial transfer to colony-forming-unit counting.
The following inclusion criteria were established:
  • Patients must be of legal age;
  • Patients must provide written consent;
  • Impacted and displaced wisdom teeth;
  • Teeth without restorations;
  • Teeth free of caries or other pathologies.

2.2. Sample Preparation

Ten wisdom teeth from ten different patients were removed under sterile conditions, transported in a sterile container containing 80% ethanol, and stored in the laboratory at 4 °C for two days before the experiment began. Before grinding, the ethanol was removed by rinsing with sterile PBS and air-drying. Remaining tissue from the teeth was removed with a scalpel. Sterile swabs were then used to remove any blood residue. The whole tooth was ground (Figure 2A). The resulting particulate therefore consisted predominantly of dentin but also contained enamel and cementum fragments and is referred to as ‘dentin granules’ for simplicity. The Smart Dentin Grinder from KometaBio (Fort Lee, NJ, USA) was used to grind the extracted wisdom teeth into an autologous dentin-based bone substitute material (dentin granules). The device was operated in its standard mode, with a 3 s grinding cycle followed by a 10 s sorting cycle. The granule particles in the upper drawer ranged in size from 300 to 1200 µm (Figure 2). Particles smaller than 300 µm fell through a sieve at the bottom of the upper drawer into a separate drawer. Only the 300–1200 µm fraction was used. Particle size was not measured further. The stated range is defined by the device’s sieve. The granules were thoroughly mixed with a sterile spatula, divided into eight equal-mass samples (300 mg each), weighed on a laboratory balance, and stored in sterile packaging. The samples were sterilized at 121 °C in the Vacuklav 24 autoclave from MELAG Medizintechnik GmbH & Co. KG (Berlin, Germany) (cycle: 40 min at 121 °C).
Figure 2. In (A), the cleaned wisdom tooth can be seen in the dentin grinder. In (B), the tooth is shown after grinding.

2.3. Contamination Procedure

Preceptrol bacterial culture of E. faecalis (ATCC 29212; ATCC, Manassas, VA, USA) was used for contamination. The contamination procedure followed the protocols previously established in our group [12,13]. Therefore, 100 µL of the E. faecalis bacterial culture was incubated with 10 mL of sterile brain heart infusion (BHI) broth (Roth, Karlsruhe, Germany) for 24 h at 37 °C in a Heraeus B6060 incubator (Heraeus Holding GmbH, Hanau, Germany). The culture was streaked onto BHI agar; a single colony was transferred into 10 mL of BHI broth and incubated for 24 h to obtain a preculture, and 100 µL of this preculture was inoculated into 10 mL of BHI broth and incubated for a further 24 h to obtain the overnight culture. For colonization, the overnight culture was vortexed, and 10 µL was inoculated into 10 mL of BHI broth. The concentration of the resulting culture was standardized to an optical density at 600 nm (OD600) of 0.8, measured with a BioPhotometer 6131 (Eppendorf AG, Hamburg, Germany), as in our previous studies [12,13]. 1 mL of the resulting liquid culture was added to 7 of the samples. The granules had been distributed into the wells of a 24-well cell culture plate (Sarstedt AG & Co. KG, Nümbrecht, Germany), one subgroup per well. The negative control was simply topped up with broth (Figure 3). The samples were incubated for the next six days at 37 °C in a C24 Shaker incubator (New Brunswick Scientific GmbH, Nuremberg, Germany) at 200 rpm. After 48 and 96 h of incubation, the liquid culture was pipetted off, and the samples were rehydrated with 1 mL of freshly prepared E. faecalis culture, obtained in the same way from the overnight culture. For the negative control, only the bacteria-free broth was changed. On the sixth day of the experiment, all samples were washed 10 times with 1 mL of phosphate-buffered saline (PBS) each to remove excess bacteria, then replenished with 1 mL of fresh PBS.
Figure 3. The seven liquid culture samples and the negative sample are shown. The individual samples are labeled (A–H).

2.4. Decontamination with Cold Atmospheric Plasma

CAP was generated with an atmospheric-pressure plasma jet (kINPen® MED, neoplas med GmbH, Greifswald, Germany) operated with argon as the working gas. The device consists of a hand-held, pen-sized applicator connected to a power supply unit and a gas supply. The plasma is ignited at a central electrode within a capillary and emerges from the nozzle as a visible effluent (Figure 4). According to the manufacturer, the effluent is homogeneous and acts over an area of approximately 1 cm2. The sterile single-use spacer attached to the tip ensures a constant distance between the nozzle and the treated surface. The plasma power was set to 5 watts and the gas flow to 4.0 slm. The samples were placed directly under the device’s sterile attachment and then exposed to the CAP jet for 1, 3, 5, and 10 min. The nozzle was directed perpendicularly onto the sample using a sterile spacer, with an approximately 10 mm gap between the nozzle and the liquid surface. This corresponds to the application distance used in our previous decontamination studies [12,13]. The granules were treated in the wells of a 24-well cell culture plate, forming a particle bed approximately 1 mm thick. They were kept covered with 1 mL of PBS throughout the exposure to prevent desiccation, which would otherwise have reduced bacterial viability independently of the treatment and to a degree proportional to exposure time. This also reflects the moist state of a freshly ground graft at chairside. Given the cross-sectional area of a well (approximately 1.9 cm2), the liquid column was approximately 5 mm, or about 4 mm above the particle bed—this height was calculated rather than measured. CAP was therefore applied in a plasma–liquid configuration, in which both direct effluent contact at the surface and longer-lived reactive species generated within the liquid contribute to the antimicrobial effect [16]. During this time, the sample vessel was manually rotated beneath the fixed nozzle at approximately 30 rotations per minute to distribute exposure across the sample (Figure 4). All CAP treatments were performed by one investigator (L.T.), who had been trained in the use of the device before the experiments. In our clinic, the plasma device is used for several studies and to treat severe wound-healing disorders. Temperature and residual liquid volume were not measured after treatment. A gas-flow-only control (gas flow without plasma ignition) was not included.
Figure 4. The violet plasma beam hits the sample below, consisting of colonized dentin granules and 1 mL of PBS.

2.5. Decontamination with Dentin Cleanser

The dentin cleanser contains 0.5 mol/L sodium hydroxide and 20% ethanol. The KometaBio protocol calls for allowing the dentin cleanser to act for 5 min, then rinsing the granules twice with the dentin wash, which consists of pure PBS. For this, the previously applied PBS solution was removed, and the granules were completely covered with dentin cleanser. Eight drops of cleanser were applied per sample, which was sufficient to completely cover the granules. The contact time was five minutes for one sample and ten minutes for the other. After the respective contact time, the cleanser was aspirated, and the granules of both cleanser groups were rinsed twice with eight drops each of dentin wash (PBS), as recommended by the manufacturer, before bacterial recovery (Section 2.6). The wells were then replenished with 1 mL of PBS. No neutralizing agent was used, and antimicrobial carry-over of residual cleanser was not assessed.

2.6. Quantification of Colony-Forming Units

Immediately after treatment (and, for the cleanser groups, after rinsing), the granules of each subgroup were transferred into 1 mL PBS. Bacteria were detached by sonication for 10 min in a Branson 2210 R-MT bath (Branson Ultrasonics, Danbury, CT, USA) in 1 mL PBS. A four-step serial dilution (10−2 to 10−5) was prepared in sterile sodium chloride solution by transferring 10 µL of the bacterial suspension into 990 µL of saline and then carrying 100 µL into 900 µL of saline three times; three 25 µL droplets of each dilution were plated onto labeled agar and incubated at 37 °C for 24 h before colonies were enumerated with a BZG 25 colony counter (WTW/Xylem Analytics, Weilheim, Germany).
For each sample, colonies were counted in the three droplets of the dilution that yielded discrete, countable colonies; counts ranged from 5 to 160 colonies per droplet. The three counts were averaged and multiplied by four to give the colony count per 100 µL of that dilution. Because the suitable dilution differed between samples, all values were referred to a common basis of 10−4: counts obtained at 10−3 were divided by ten and counts obtained at 10−5 were multiplied by ten. Of the 70 colonized subgroups, 58 were evaluated at 10−4, 7 at 10−5, and 5 at 10−3. All values reported in this study are therefore colony counts per 100 µL of the 10−4 dilution and correspond to ×104 CFU/100 µL, or ×105 CFU/mL, of the sample suspension. As a worked example, in tooth 1 the 5 min CAP subgroup gave 104, 99 and 102 colonies in the three 25 µL droplets of the 10−4 dilution; the mean of 101.7 colonies per 25 µL corresponds to 406.7 per 100 µL of this dilution and thus to 4.07 × 107 CFU/mL of the sample suspension. No droplet showed confluent growth at the dilutions evaluated, and no colonized subgroup yielded a count of zero; the sterile negative control remained free of growth in every tooth.

2.7. Live/Dead Fluorescence Staining and Imaging

For a complementary, image-based assessment of viability, aliquots of every subgroup were labeled with the LIVE/DEAD BacLight Bacterial Viability Kit (Thermo Fisher Scientific, Waltham, MA, USA). The staining solution was prepared by adding 0.75 µL of each dye to 500 µL of sodium chloride solution; the bacterial suspension was centrifuged at 3000 rpm for 10 min, and 50 µL of the suspension was mixed with 50 µL of the staining solution. After a PBS rinse, each granule sample was transferred onto a glass slide, overlaid with 5 µL of the combined working solution, and mounted under a coverslip. Labeling proceeded for 10–15 min at room temperature in the dark, after which the slides were examined without delay on an Axioplan 2 microscope with an AxioCam MRc camera and AxioVision software (Carl Zeiss Microscopy, Jena, Germany). For each subgroup, ten randomly chosen fields were captured at ×100, using the 470/40 filter to visualize viable (green) and the 546/12 filter to visualize membrane-compromised (red) organisms. The two channels were recorded separately rather than merged, as described previously [12]. Exposure settings were identical for all samples. The ten fields per subgroup were selected at random, without prior inspection of the stained preparation [12]. Dentin background fluorescence was assessed on the sterile negative control, which was stained and imaged in the same way. Scale bars were added to all images. This evaluation was purely descriptive and was not used to quantify or confirm the culture results, as membrane integrity and colony formation represent different endpoints.

2.8. Statistical Analysis

Statistical analyses were performed with SPSS 31.0 (IBM Corp., Armonk, NY, USA). Because each of the ten wisdom teeth was divided into eight aliquots, so that each tooth contributed one sample to each experimental group, the groups were treated as related (matched) rather than independent. Continuous variables were summarized as mean ± standard deviation and as median with range (Table 1), and normality of the paired differences was assessed with the Shapiro–Wilk test (all p ≥ 0.06). Sphericity was assessed using the Greenhouse–Geisser estimate of ε; because ε was low (0.46), the Greenhouse–Geisser correction was applied. Subsequently, an overall comparison of the seven colonized groups was performed with a repeated-measures analysis of variance, followed by pairwise comparisons predefined for this analysis using paired t-tests (each treatment vs. the positive control, the CAP intervals among each other, the two cleanser intervals, and 5 min of CAP vs. each cleanser protocol). To control the family-wise error rate, we adjusted all 13 p-values jointly using the Holm–Bonferroni step-down procedure; unless stated otherwise, all reported p-values are Holm-adjusted. For each comparison, we report the mean paired difference with its unadjusted 95% confidence interval and the unadjusted and adjusted p-values (Table 2). As a sensitivity analysis, we performed the Friedman test and Wilcoxon signed-rank tests with the same Holm adjustment. Because no equivalence margin was predefined, a non-significant difference was not interpreted as evidence of equivalence. A (corrected) p-value < 0.05 was considered statistically significant. No a priori sample-size calculation was performed; we chose 10 teeth based on previous in vitro decontamination studies by our group [17] and feasibility. To characterize the sensitivity of the design, we estimated the minimum detectable standardized paired effect size: with n = 10 paired specimens, a two-sided α of 0.05, and 80% power, only effects of Cohen’s dz ≥ 1.0 could be detected reliably before adjustment for multiple comparisons.
Table 1. Colony counts of the seven colonized subgroups (n = 10 teeth each), expressed per 100 µL of the 10−4 dilution (×104 CFU/100 µL of the sample suspension; see Section 2.6): mean, median, standard deviation (SD), minimum and maximum.
Table 2. Paired comparisons of the colony counts (per 100 µL of the 10−4 dilution; n = 10 teeth; paired t-tests). Differences are given as mean paired difference (A − B) with the unadjusted 95% confidence interval. Adjusted p-values were obtained with the Holm–Bonferroni procedure across all 13 comparisons. DC, dentin cleanser.

3. Results

All ten wisdom teeth yielded sufficient particulate dentin to populate the eight subgroups, so that every group could be evaluated. The untreated, colonized positive control carried the highest bacterial load (mean 430 ± 121; median 414; range 227–573; for the unit see Section 2.6), whereas the sterile negative control remained free of growth, confirming the absence of extraneous contamination. All decontamination protocols reduced the number of viable adherent bacteria relative to the positive control, and the repeated-measures analysis of variance confirmed a highly significant overall difference among the seven colonized groups (F(6, 54) = 11.5; p < 0.001). Sphericity was markedly violated (Greenhouse–Geisser ε = 0.46), but the difference remained significant after correction (F(2.8, 25.1) = 11.5; p < 0.001), as in the Friedman test (χ2(6) = 35.4; p < 0.001). All paired comparisons are summarized in Table 2. None of the treated samples were culture-negative (Table 1).
Within the CAP groups, mean counts decreased from 363 ± 107 after 1 min to 277 ± 92 after 3 min and reached their lowest value of 253 ± 119 after 5 min. One minute of CAP did not differ significantly from the untreated control (p = 0.594), whereas 5 min produced a significantly greater reduction than 1 min (p = 0.001) and significantly lowered the count relative to the positive control (p = 0.043). Three minutes of CAP yielded significantly lower counts than 1 min (p = 0.025) but did not differ significantly from the untreated control (p = 0.055) or from 5 min (p = 0.594). Extending the exposure from 5 to 10 min did not result in a lower mean count; the mean was in fact higher (316 ± 160; p = 0.594) and the variability was the greatest of all groups. Ten minutes of CAP did not differ significantly from the untreated control (p = 0.594). This non-significant difference does not demonstrate a plateau; 5 min was the CAP interval with the lowest observed mean count.
The chemical dentin cleanser produced the numerically lowest counts of all groups, with a mean of 166 ± 83 after 5 min and 100 ± 79 after 10 min. The 10 min protocol yielded lower counts than the 5 min protocol (mean paired difference −66, 95% CI −111 to −21), a difference that did not reach significance after correction for multiple comparisons (p = 0.065) but did so in the Wilcoxon sensitivity analysis (adjusted p = 0.025). Both cleanser protocols significantly reduced the bacterial load relative to the untreated control (p = 0.003 and p = 0.001).
When comparing the CAP interval with the lowest observed mean count with the chemical cleanser, 5 min of CAP did not differ significantly from 5 min of dentin cleanser (mean paired difference 87, 95% CI −32 to 205; p = 0.594). Although the 10 min cleanser produced the numerically lowest counts of the whole experiment, its difference from 5 min of CAP did not reach statistical significance after correction for multiple comparisons (mean paired difference 153, 95% CI 27 to 279; unadjusted p = 0.023, adjusted p = 0.136). The unadjusted confidence interval thus excluded zero, indicating that the 10 min cleanser tended to leave fewer viable bacteria than 5 min of CAP, although this difference did not persist after correction for multiple comparisons. The wide confidence intervals reflect the considerable inter-tooth variability and indicate that the study lacked the precision to exclude differences of potentially relevant magnitude. In four of the ten teeth, the 10 min cleanser left a higher count than 5 min of CAP (Figure 5; Supplementary Table S1). Thus, a statistically significant difference between 5 min of CAP and the cleanser was not detected under the present experimental conditions; equivalence or non-inferiority was not tested and cannot be inferred.
Figure 5. Colony counts (per 100 µL of the 10−4 dilution) after 5 min of CAP and after 10 min of dentin cleanser in the ten teeth. Points represent individual teeth; lines connect the paired samples of each tooth. Green: teeth with a higher count after the dentin cleanser (n = 4); blue: teeth with a lower count (n = 6); black diamonds: means. Mean counts were lower after the dentin cleanser (mean paired difference 153, 95% CI 27 to 279), but the difference was not statistically significant after correction for multiple comparisons (adjusted p = 0.136; paired t-test).
Although the analysis of the live/dead fluorescence was merely descriptive, it was qualitatively consistent with the culture results. Samples of the positive control and CAP groups showed dense clusters of viable (green) bacteria adhering to the dentin granules, whereas the dentin-cleanser groups showed fewer adherent viable organisms. After 5 min of treatment, somewhat more residual viable bacteria were visible following CAP than following the dentin cleanser (Figure 6), consistent with the numerical trend in colony-forming-unit counts and the representative agar plates (Figure 7). These images are illustrative only and do not provide quantitative confirmation of the culture data; moreover, they do not allow conclusions on bacterial colonization within the dentinal tubules.
Figure 6. Representative live/dead fluorescence images of dentin granules after 5 min of CAP (A) and 5 min of dentin cleanser (B). Green: viable bacteria (SYTO 9). The two channels were recorded separately; the panels show the green channel. Original magnification ×100; scale bars = 50 µm.
Figure 7. Representative agar plates after 5 min of CAP (A) and 5 min of dentin cleanser (B). Each quadrant corresponds to one dilution step (10−2 to 10−5), plated as three 25 µL droplets.

4. Discussion

This in vitro study compared CAP with the manufacturer’s chemical dentin cleanser for decontaminating autogenous dentin granules colonized with E. faecalis. Both approaches reduced the number of recoverable bacteria relative to the untreated control. This reduction was statistically significant for both cleanser protocols and for 5 min of CAP, but not for 1, 3, or 10 min of CAP. Descriptively, the chemical cleanser produced the numerically lowest counts, reaching its minimum after 10 min, whereas among the CAP intervals the lowest mean count was observed after 5 min. However, after correction for multiple comparisons, a statistically significant difference between CAP and the cleanser was not detected, although the unadjusted confidence interval for the comparison with the 10 min cleanser excluded zero. Accordingly, the null hypothesis that CAP and the chemical dentin cleanser do not differ in their decontaminating efficacy could not be rejected. Given the limited sample size and the width of the confidence intervals, this must not be interpreted as evidence of equivalence. The robust, statistically significant effects were the reductions achieved by both cleanser protocols and by 5 min of CAP relative to the untreated control. Importantly, neither method produced culture-negative granules: viable E. faecalis was recovered from every treated sample. This persistent bacterial recovery is more relevant than the absence of a significant difference between selected treatment groups.
The behavior of CAP is best understood from its physical mode of action. CAP inactivates micro-organisms through short-lived reactive oxygen and nitrogen species delivered essentially along the line of sight of the plasma jet and acting predominantly at exposed surfaces [11]. On flat, readily accessible substrates, this is highly effective. CAP produced a pronounced reduction of E. faecalis on GBR membranes [17], and it markedly lowered the bacterial load on titanium implant surfaces [12]. Autogenous dentin granules, however, do not present such a surface. They form a porous, three-dimensional bulk in which bacteria are sheltered in the interstices between particles and within the dentinal tubules, niches in which E. faecalis is known to persist and resist antimicrobial treatment [8]. Mercury porosimetry of ground human teeth has demonstrated a total porosity of up to 29% and an internal pore area of 1.89 m2/g [3], so that a considerable part of the available surface is not accessible to a line-of-sight treatment. Whether intratubular colonization occurred in the present samples was not examined. Moreover, in the present set-up, the granules were covered with 1 mL PBS, so the plasma effluent interacted primarily with the liquid surface. Plasma-treated liquids accumulate longer-lived reactive species such as hydrogen peroxide, nitrite, and nitrate [16], which may have contributed to the antimicrobial effect independently of direct line-of-sight exposure; the relative contributions of the two pathways cannot be separated in this study.
Although atmospheric plasma can penetrate porous structures to some extent, complete biofilm removal from micro-structured titanium has been reported only when CAP was combined with an additional air–water spray [18], and CAP combined with mechanical or air-polishing methods consistently outperforms CAP alone [19,20]. Most tellingly, on collagen membranes, CAP cleared the accessible surface while the deeper layers remained a microbial reservoir [17]. In the present model, manual agitation was intended to distribute the exposure but could not guarantee that every particle surface was reached, which may have contributed to the lack of further reduction beyond 5 min and the pronounced variability at 10 min.
The choice of E. faecalis as the test organism sets a deliberately high bar and further explains why sterility was not reached. Beyond its persistence in dentinal tubules and its resistance to conventional antiseptics [8], two properties are directly relevant to a plasma-based approach. First, Gram-positive bacteria, with their thicker peptidoglycan cell wall, are inactivated by cold plasma less readily than Gram-negative species [21]. It may therefore be hypothesized that some members of a mixed oral flora are more susceptible to CAP than E. faecalis. However, the response of a polymicrobial biofilm cannot be inferred from the relative plasma susceptibility of its individual species, as interspecies interactions and the biofilm matrix may confer additional tolerance. This hypothesis requires validation in multispecies models. Second, E. faecalis itself produces extracellular superoxide and hydrogen peroxide [22] and is thus constitutively adapted to oxidative stress, the very mechanism through which CAP exerts its antimicrobial effect. A robust, oxidative-stress-tolerant organism embedded in a porous matrix may represent a particularly demanding scenario for CAP.
Extending CAP from 5 to 10 min did not further reduce the mean count, which was slightly higher and more variable, although this difference was not statistically significant (p = 0.594). On collagen and PTFE membranes, by contrast, 10 min of CAP reduced the bacterial load further than 5 min [13]. This difference between a flat and a particulate substrate may indicate that the absence of an additional effect here relates to the three-dimensional, porous nature of the dentin granules rather than to exposure time itself. Longer plasma exposure is known to alter the surface chemistry of the treated material. Plasma introduces oxygen-containing functional groups such as C–O and C=O onto organic substrates [23,24], and increasing CAP time on collagen membranes raises the surface carbonyl (C=O) content. This increase correlated negatively with decontamination, with CFU counts rising as treatment time increased [17]. Surface carbonyl groups have been linked to enhanced cell, and potentially bacterial, attachment [25], and CAP-induced increases in surface wettability are themselves associated with greater bacterial adhesion [26]. Because dentin is a protein-rich, collagen-bearing substrate, it is conceivable that comparable surface modification could partly offset the antimicrobial effect at longer exposure times. However, surface chemistry, wettability and bacterial re-adhesion were not measured in the present study, and the small, non-significant difference between 5 and 10 min does not establish such an effect; this possible mechanism should therefore be regarded as a hypothesis for future investigation. A time dependence of reactive-oxygen-species-mediated inhibition has been reported on other dental materials [27].
The numerically lower counts of the chemical dentin cleanser are consistent with its complementary mode of action. As a liquid, the alkaline sodium hydroxide/ethanol solution penetrates the inter-particle spaces and dentinal tubules and reaches bacteria that a surface treatment cannot, which accords with the manufacturer’s intention of producing a bacteria-free graft. Even so, the cleanser did not sterilize the granules, leaving a residual count of about 1.0 × 107 CFU/mL after 10 min, consistent with the broader observation that no single method fully decontaminates a complex three-dimensional substrate [12]. For teeth carrying a heavy pre-existing bacterial burden, this residual load is clinically relevant and argues for careful case selection. A threshold of residual bacteria compatible with uneventful healing has not been defined for dentin grafts; the finding that an antimicrobial adjunct improves mineralization in infected sockets [7] nevertheless indicates that the microbial burden carried by the graft influences the regenerative outcome. These findings must be weighed against the biological trade-offs of the two methods. The chemical cleanser is a strong alkali combined with ethanol and may denature or deplete the very organic matrix, collagen, and osteoinductive bone morphogenetic proteins that are thought to underlie the regenerative potential of dentin grafts [2]. This was not assessed in the present study. CAP, by contrast, is non-thermal, does not require an added liquid disinfectant, and has been reported to enhance surface wettability, cell spreading, osteoblast function, and peri-implant wound healing on implant materials [28,29,30]. It may therefore be hypothesized that CAP could decontaminate dentin while preserving, or even enhancing, matrix bioactivity. This hypothesis was not tested here: collagen integrity, growth-factor retention, cytocompatibility and osteogenic response were not assessed, and the granules had already been exposed to ethanol and autoclaving before contamination, which may themselves have altered the organic matrix. Moreover, any such advantage may be double-edged, because the same surface activation that favors host cells can also favor bacterial re-adhesion [26]. Combined protocols, for example, a chemical cleansing step followed by brief CAP, analogous to the CAP-plus-mechanical protocols investigated on implant surfaces [19,20], may be a reasonable direction for further research; however, such protocols were not tested here and remain a proposal. From a clinical standpoint, the established chemical protocol remains the benchmark and is both inexpensive and simple. The present data do not support using CAP as a stand-alone alternative, as graft implantation, cytocompatibility, osteogenic response, and a clinically acceptable residual bacterial threshold were not assessed.
Several limitations of the present study should be borne in mind. It is an in vitro single-species model. E. faecalis is a deliberately robust but non-representative stand-in for the polymicrobial oral biofilm, so the absolute reductions reported here cannot be transferred directly to the clinical situation. The teeth were stored in 80% ethanol and autoclaved before contamination to obtain a sterile, standardized substrate. This does not reproduce the chairside processing of freshly extracted teeth and may have influenced bacterial attachment and the organic matrix. Six days of incubation does not by itself establish a mature biofilm, and intratubular colonization was not verified. CFU counting captures only culturable, detachable bacteria and, together with the qualitative live/dead staining, provides a functional but not exhaustive picture. CAP was applied manually; although the spacer kept the nozzle-to-sample distance constant, the distribution of the exposure across the particle bed remained operator-dependent and probably contributed to the observed variability. A gas-flow-only control was not included, so physical effects of the gas jet (e.g., drying or agitation) cannot be separated from plasma-specific effects, and temperature and liquid evaporation were not monitored. Because the granules were covered with PBS, the contributions of direct plasma exposure and of reactive species generated in the liquid cannot be distinguished. For the cleanser groups, neither neutralization nor antimicrobial carry-over was assessed, so that residual sodium hydroxide or ethanol may have continued to act during sonication and plating. No a priori sample-size calculation was performed; with ten teeth, the precision of the between-method comparison was limited, and non-significant differences must not be interpreted as equivalence. Neither the processing order nor the colony counting was randomized or blinded; because the subgroups of each tooth were always treated in the same sequence, starting with the longest CAP exposure, the interval between the end of the colonization period and bacterial recovery differed systematically between the subgroups. Particle size was not characterized beyond the 300–1200 µm range defined by the grinder sieve. Finally, the effect of either method on collagen integrity, growth-factor retention, osteogenic capacity, mechanical properties, and cytocompatibility of the granules was not assessed. Future studies should employ polymicrobial and in vivo models, standardize plasma delivery, test combined chemical–plasma protocols, and evaluate the biological quality of the graft after treatment.

5. Conclusions

Within the limitations of this in vitro study, both CAP and the chemical dentin cleanser reduced the recoverable E. faecalis load on tooth-derived granules compared with the untreated control; this reduction was statistically significant for 5 min of CAP and for both cleanser protocols. The cleanser groups showed the lowest observed mean counts, and 5 min of CAP had the lowest observed mean count. After correction for multiple comparisons, no statistically significant difference was detected between 5 min of CAP and the cleanser, although the 10 min cleanser tended to leave fewer viable bacteria; the study did not establish equivalent efficacy, and viable bacteria were recovered after every treatment. The clinical suitability of CAP for decontaminating autogenous dentin grafts was not assessed and requires adequately powered studies, multispecies models, and evaluation of the biological properties of the treated graft.

Supplementary Materials

The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/jfb17120591/s1. Table S1: Anonymized tooth-level colony counts of all subgroups, including the individual droplet counts and the dilution evaluated.

Author Contributions

Conceptualization, J.W. (Juliane Wagner), A.G., J.S. and J.W. (Jörg Wiltfang); methodology, D.S., L.T. and F.L.; validation, C.M.; formal analysis, D.S. and F.L.; investigation, A.G. and C.M.; resources, J.W. (Jörg Wiltfang) and J.S.; data curation, L.T., D.S. and F.L.; writing—original draft preparation, J.S.; writing—review and editing, A.G.; visualization, D.S., F.L. and J.W. (Juliane Wagner); supervision, J.S. and J.W. (Jörg Wiltfang). All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The current study was approved by the ethics committee of Christian Albrechts University, Kiel, Germany (D441/25), approval date 26 February 2026.

Data Availability Statement

The anonymized tooth-level data are provided in Supplementary Table S1. Further data are available on request from the corresponding authors.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Tan, W.L.; Wong, T.L.; Wong, M.C.; Lang, N.P. A systematic review of post-extractional alveolar hard and soft tissue dimensional changes in humans. Clin. Oral Implant. Res. 2012, 23, 1–21. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Bessho, K.; Tanaka, N.; Matsumoto, J.; Tagawa, T.; Murata, M. Human dentin-matrix-derived bone morphogenetic protein. J. Dent. Res. 1991, 70, 171–175. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Sarna-Boś, K.; Boguta, P.; Skic, K.; Wiącek, D.; Maksymiuk, P.; Sobieszczański, J.; Chałas, R. Physicochemical properties and surface characteristics of ground human teeth. Molecules 2022, 27, 5852. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Kim, Y.K.; Lee, J.H.; Um, I.W.; Cho, W.J. Guided Bone Regeneration Using Demineralized Dentin Matrix: Long-Term Follow-Up. J. Oral Maxillofac. Surg. 2016, 74, 515.e1–515.e9. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Pohl, V.; Pohl, S.; Sulzbacher, I.; Fuerhauser, R.; Mailath-Pokorny, G.; Haas, R. Alveolar Ridge Augmentation Using Dystopic Autogenous Tooth: 2-Year Results of an Open Prospective Study. Int. J. Oral Maxillofac. Implants 2017, 32, 870–879. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Pohl, S.; Binderman, I.; Tomac, J. Maintenance of Alveolar Ridge Dimensions Utilizing an Extracted Tooth Dentin Particulate Autograft and PlateletRich Fibrin: A Retrospective Radiographic ConeBeam Computed Tomography Study. Materials 2020, 13, 1083. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Elbehwashy, M.T.; Hosny, M.M.; Elfana, A.; Saleh, H.A.; El-Sayed, K.F. Autogenous demineralized dentin graft-based strategies with or without I-PRF and metronidazole for ridge preservation in infected sockets: A randomized clinical trial. J. Periodontal Res. 2026, 61, 1033–1048. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Stuart, C.H.; Schwartz, S.A.; Beeson, T.J.; Owatz, C.B. Enterococcus faecalis: Its role in root canal treatment failure and current concepts in retreatment. J. Endod. 2006, 32, 93–98. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Gan, L.; Jiang, J.; Duan, J.W.; Wu, X.J.Z.; Zhang, S.; Duan, X.R.; Song, J.Q.; Chen, H.X. Cold atmospheric plasma applications in dermatology: A systematic review. J. Biophotonics 2021, 14, e202000415. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Weiss, M.; Daeschlein, G.; Kramer, A.; Burchardt, M.; Brucker, S.; Wallwiener, D.; Stope, M.B. Virucide properties of cold atmospheric plasma for future clinical applications. J. Med. Virol. 2017, 89, 952–959. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Jungbauer, G.; Moser, D.; Müller, S.; Pfister, W.; Sculean, A.; Eick, S. The Antimicrobial Effect of Cold Atmospheric Plasma against Dental Pathogens-A Systematic Review of In-Vitro Studies. Antibiotics 2021, 10, 211. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Flörke, C.; Janning, J.; Hinrichs, C.; Behrens, E.; Liedtke, K.R.; Sen, S.; Christofzik, D.; Wiltfang, J.; Gülses, A. In-vitro assessment of the efficiency of cold atmospheric plasma on decontamination of titanium dental implants. Int. J. Implant Dent. 2022, 8, 12. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Weitkamp, J.-T.; Hogreve, A.; Spille, J.; Veziroglu, S.; Aktas, O.C.; Flörke, C.; Liedtke, K.R.; Wiltfang, J.; Gülses, A. Effectiveness of cold atmospheric plasma in decontaminating Enterococcus faecalis colonized collagen and PTFE membranes used in guided bone regeneration: A comparative in vitro investigation. Int. J. Implant Dent. 2024, 10, 53. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Koban, I.; Holtfreter, B.; Hübner, N.-O.; Matthes, R.; Sietmann, R.; Kindel, E.; Weltmann, K.-D.; Welk, A.; Kramer, A.; Kocher, T. Antimicrobial efficacy of non-thermal plasma in comparison to chlorhexidine against dental biofilms on titanium discs in vitro—Proof of principle experiment. J. Clin. Periodontol. 2011, 38, 956–965. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Hui, W.L.; Perrotti, V.; Iaculli, F.; Piattelli, A.; Quaranta, A. The Emerging Role of Cold Atmospheric Plasma in Implantology: A Review of the Literature. Nanomaterials 2020, 10, 1505. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Bruggeman, P.J.; Kushner, M.J.; Locke, B.R.; Gardeniers, J.G.E.; Graham, W.G.; Graves, D.B.; Hofman-Caris, R.C.H.M.; Maric, D.; Reid, J.P.; Ceriani, E.; et al. Plasma–liquid interactions: A review and roadmap. Plasma Sources Sci. Technol. 2016, 25, 053002. [Google Scholar] [CrossRef] [Scilit]
  17. Gülses, A.; Dohrmann, L.; Aktas, O.C.; Wagner, J.; Veziroglu, S.; Tjardts, T.; Hartig, T.; Liedtke, K.R.; Wiltfang, J.; Acil, Y.; et al. Decontaminative Properties of Cold Atmospheric Plasma Treatment on Collagen Membranes Used for Guided Bone Regeneration. J. Funct. Biomater. 2023, 14, 372. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Rupf, S.; Idlibi, A.N.; Marrawi, F.A.; Hannig, M.; Schubert, A.; von Mueller, L.; Spitzer, W.; Holtmann, H.; Lehmann, A.; Rueppell, A.; et al. Removing biofilms from microstructured titanium ex vivo: A novel approach using atmospheric plasma technology. PLoS ONE 2011, 6, e25893. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Kamionka, J.; Matthes, R.; Holtfreter, B.; Pink, C.; Schlüter, R.; von Woedtke, T.; Kocher, T.; Jablonowski, L. Efficiency of cold atmospheric plasma, cleaning powders and their combination for biofilm removal on two different titanium implant surfaces. Clin. Oral Investig. 2022, 26, 3179–3187. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Matthes, R.; Jablonowski, L.; Pitchika, V.; Holtfreter, B.; Eberhard, C.; Seifert, L.; Gerling, T.; Scholten, L.V.; Schlüter, R.; Kocher, T. Efficiency of biofilm removal by combination of water jet and cold plasma: An in-vitro study. BMC Oral Health 2022, 22, 157. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Mai-Prochnow, A.; Clauson, M.; Hong, J.; Murphy, A.B. Gram positive and Gram negative bacteria differ in their sensitivity to cold plasma. Sci. Rep. 2016, 6, 38610. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Huycke, M.M.; Abrams, V.; Moore, D.R. Enterococcus faecalis produces extracellular superoxide and hydrogen peroxide that damages colonic epithelial cell DNA. Carcinogenesis 2002, 23, 529–536. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Azam, M.T.; Khan, A.S.; Muzzafar, D.; Faryal, R.; Siddiqi, S.A.; Ahmad, R.; Chauhdry, A.A.; Rehman, I.U. Structural, Surface, in vitro Bacterial Adhesion and Biofilm Formation Analysis of Three Dental Restorative Composites. Materials 2015, 8, 3221–3237. [Google Scholar] [CrossRef] [Scilit]
  24. Morent, R.; De Geyter, N.; Leys, C.; Gengembre, L.; Payen, E. Comparison between XPS- and FTIR-analysis of plasma-treated polypropylene film surfaces. Surf. Interface Anal. 2008, 40, 597–600. [Google Scholar] [CrossRef] [Scilit]
  25. Ertel, S.I.; Chilkoti, A.; Horbett, T.A.; Ratner, B.D. Endothelial cell growth on oxygen-containing films deposited by radio-frequency plasmas: The role of surface carbonyl groups. J. Biomater. Sci. Polym. Ed. 1991, 3, 163–183. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. Wassmann, T.; Kreis, S.; Behr, M.; Buergers, R. The influence of surface texture and wettability on initial bacterial adhesion on titanium and zirconium oxide dental implants. Int. J. Implant Dent. 2017, 3, 32. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. Yang, Y.; Zheng, M.; Jia, Y.N.; Li, J.; Li, H.P.; Tan, J.G. Time-dependent reactive oxygen species inhibit Streptococcus mutans growth on zirconia after a helium cold atmospheric plasma treatment. Mater. Sci. Eng. C 2021, 120, 111633. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Wagner, G.; Eggers, B.; Duddeck, D.; Kramer, F.-J.; Bourauel, C.; Jepsen, S.; Deschner, J.; Nokhbehsaim, M. Influence of cold atmospheric plasma on dental implant materials—An in vitro analysis. Clin. Oral Investig. 2022, 26, 2949–2963. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Duske, K.; Koban, I.; Kindel, E.; Schröder, K.; Nebe, B.; Holtfreter, B.; Jablonowski, L.; Weltmann, K.D.; Kocher, T. Atmospheric plasma enhances wettability and cell spreading on dental implant metals. J. Clin. Periodontol. 2012, 39, 400–407. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Harada, A.; Sasaki, H.; Asami, Y.; Hanazawa, K.; Miyazaki, S.; Sekine, H.; Yajima, Y. Effects of the application of low-temperature atmospheric plasma on titanium implants on wound healing in peri-implant connective tissue in rats. Int. J. Implant Dent. 2024, 10, 15. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.