Skip to Content
You are currently on the new version of our website. Access the old version .
  • Article
  • Open Access

29 March 2024

19 Pages

Stability Analysis in a Direct-Current Shipboard Power System with Parallel Permanent Magnet Synchronous Generators and Supercapacitor Integration

,
,
,
and
1
School of Electrical Engineering, Naval University of Engineering, Wuhan 430030, China
2
Shanghai Marine Diesel Engine Research Institute, Shanghai 201108, China
3
College of Automation, Jiangsu University of Science and Technology, Zhenjiang 212100, China
*
Authors to whom correspondence should be addressed.

Abstract

This paper investigates the small-signal stability of a DC shipboard power system (SPS) with the integration of a supercapacitor. As an efficient energy storage solution, supercapacitors can not only provide rapid energy response to sudden power demand spikes, effectively mitigating load fluctuations, but also enhance the system’s resilience to disturbances. In the context of the parallel operation of two Permanent Magnet Synchronous Generators (PMSGs), the inclusion of supercapacitors may alter the system’s dynamic behaviors, thereby affecting its small-signal stability. This paper develops the small-signal model of SPS and explores the small-signal model under various power distribution strategies in the parallel operation of diesel generator sets. Through the calculation of eigenvalues and influence factors, the system’s oscillation modes are analyzed, and key parameters affecting the stability of the DC distribution system are identified. Furthermore, this paper meticulously examines the specific impacts of electrical and control parameter variations on the system’s small-signal stability. Simulation experiments validate the accuracy of the small-signal stability analysis after supercapacitor integration into SPS.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.