Numerical and Experimental Research on Rectification Measures for a Contraction Diversion Pier in a Pumping Station

,
,
,
,
and
1
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, China
2
Jurong Water Conservancy Bureau in Jiangsu Province, Jurong 212499, China
*
Author to whom correspondence should be addressed.
This article belongs to the Section Ocean Engineering

Abstract

In order to improve the flow state of a forebay, a contraction diversion pier is discovered, the geometric parameters of which affect the improvement of the flow state. In this paper, the standard k-ε model in the computational fluid dynamics (CFD) numerical simulation method is used to research the flow state improvement of the forebay with a contraction diversion pier. In our research, the single factor method is used to analyze the influence of different geometric parameters. Then, the optimal geometric parameters of the contraction diversion pier are given. Results show that the contraction diversion pier can be used to concentrate the water flow. In the area where reflux is formed, the contraction diversion guides water flow along the diversion pier wall. In particular, when the retractable diversion pier is located in the middle of a reflux zone, the water backflow is effectively reduced, the flow state is improved, and the inlet condition of the pump is optimized. By comparing the cross-sectional streamlines, the velocity contour, the normal velocity uniformity of the longitudinal section, and the normal weighted mean angle, the optimal geometric parameters of the contraction diversion pier are obtained as follows: the distance from the contraction pier to the inlet sump is 0.1 L, the contraction angle is 20°, and the length of pier is 0.3 L.

1. Introduction

A forebay is the connecting section of the bay channel and the inlet sump, and its function is to spread the water flow smoothly to provide a good flow state for the inlet sump. It is easily restricted by the terrain conditions and the surroundings of the pumping station, which makes the layout of the station tight and difficult to provide a suitable layout [1,2,3]. Adverse flow conditions such as backflow, vortex, and deflection are often caused by an unideal layout which worsens the pump inlet conditions. As a result, the pump performance decreases, and cavitation and vibration are caused in the unit, seriously affecting the safe and stable operation of the coastal pumping station [4,5,6,7]. Therefore, it is essential to take measures to improve the flow pattern of the forebay [8,9,10,11,12,13,14,15].
As a widely used rectification measure, the bottom slope can effectively improve the flow state of the forebay. Through the swirling action of flow lifting and rolling behind the bottom sill, the backflow formation conditions on both sides of the forebay are eliminated, the water flow is fully diffused, and a better velocity distribution is provided for the inlet [16]. In view of the adverse flow patterns, such as backflow and vortex, existing in the forebay, Li Zhixiang et al. optimized the shape and layout parameters of the bottom sill by using the surface model response based on numerical simulation technology [17,18]. Using the computational fluid dynamics method, Ying Jiawei et al. used the volume of fluid (VOF) model to study the improvement effect of the bottom still and columns on the water flow pattern of the forebay of the pumping station [19]. Luo Can et al. used computational fluid dynamics numerical simulation techniques to study the rectification measures at the bottom of the forebay, discussed the influence of the position, height, and top width of the bottom sill, and put forward the scheme of setting the bottom sill [20]. Feng Jiangang et al. put forward a rectification measure of double bottom sills in the downstream channel in view of the poor flow state of the flow in the pump sluice project. In further research, the VOF method was used to explore the rectification effect and verify the physical model of the calculation results [21]. As another widely used rectification measure, columns can destroy the front vortex and improve the flow velocity distribution [22,23]. By means of numerical simulation, Li Yanyan studied the influence of columns on the flow state, unit efficiency, and stability of the pumping station [24,25]. A diversion pier can effectively improve the flow state by eliminating the backflow and smoothing the water streamline [26,27,28,29,30,31,32]. In order to improve the flow pattern of the forebay of the lateral inlet coastal pumping station, based on CFX software, Zhang Congcong carried out a numerical simulation without rectification measures and the arrangement of a “Y” shape diversion pier. They then analyzed the influence of the position, height, angle, length, and other factors of the “Y” shape diversion pier on the flow pattern of the forebay [33]. Xu Bo used computational fluid dynamics to numerically simulate the flow pattern of the forebay in the pump sluice station and studied the influence of the length of the orifice diversion pier. In the research, the width of the orifice, the distance between the adjacent orifice centers, and the height of the orifice are considered for the improvement of the flow pattern [34,35].
To rectify the poor flow pattern in the forebay of the pumping station, previous researchers proposed measures such as a Y-shaped diversion pier, diffusion diversion pier, bottom sill, water pressure plate, and column. In this paper, a contraction diversion pier is creatively proposed to improve the flow pattern of a small pump station with an asymmetric forebay shape. This paper first establishes the calculation domain and the calculation model. In order to compare the applicability of different turbulence models in the coastal pump station, the standard k-ε, RNG k-ε, and k-ω turbulence models were used to simulate the computational domain, and the simulation results were compared with the experimental data. The standard k-ε model was finally adopted and then a numerical simulation and physical model experiments were carried out to compare and analyze the flow patterns in the forebay. By analyzing the original scheme and the “shrinkage” diversion pier rectification scheme with different parameters, the reasonableness of the rectifying of the “shrinkage” diversion pier is put forward, and the suitable geometric parameters of the diversion pier are given. This rectifying measure can improve the poor flow pattern and enhance velocity distribution uniformity in the forebay, which can provide a reference for the design and transformation of the same type of coastal pumping station.

2. Physical Model and Numerical Calculation Method

2.1. Physical Model

In this paper, an asymmetric forebay is selected as the research object. In order to ensure the accuracy of numerical calculation, the calculation domain includes the diversion channel, culvert, forebay, water inlet sump, and water inlet pipe, as shown in Figure 1. Considering that the main content of the research is the flow state of the forebay, the rotation of the pump impeller has little influence on the flow of the forebay, so the rotating machinery is not simulated in the process of numerical calculation. Although the blade rotation is not considered, the calculation domain still includes the flared pipe, 90° bend pipe, and straight outlet pipe. The model section of the computing domain of the coastal pumping station is shown in Figure 1.
Figure 1. The computing domain.

2.2. Hydrodynamic Equations

In order to compare the simulation results of the different turbulence models used in the forebay flow state with the experimental data, the k-ω, standard k-ε, and RNG k-ε turbulence models were simulated and the results were compared with the experimental data.
Figure 2 shows the axial velocity distribution simulated by the different turbulence models in the inlet sump of pump 1#. It can be seen from the figure that the results of the k-ω model are much larger than the experimental data. The simulation results of the standard k-ε turbulence model and RNG k-ε model are similar at the bottom of the forebay, but they are both different from reality. From a theoretical point of view, the RNG k-ε model is better for large curvature flow models. From the actual results, compared with the two models, the results show that the standard k-ε model is more effective in surface simulation. We speculate that the RNG k-ε model does not exert an advantage due to the small curvature of the surface fluid. Therefore, we adopt the standard k-ε turbulence model in the subsequent numerical simulation.
Figure 2. Velocity distribution under different turbulence models and experiments.
The numerical simulation is based on the Reynolds time-averaged N-S equation and standard k-ε turbulence model to simulate the flow state, and the discrete equations are solved by a separate solver [36,37]. The algorithm is a SIMPLEC algorithm. The flow state in the forebay satisfies the mass conservation equation and momentum-conservation equation. They are
∂ u i ∂ x i = 0
∂ ∂ x j ( ρ u i u j ) = − ∂ p ∂ x + ∂ ∂ x j ( μ ∂ u i ∂ u x j ) + ∂ ∂ x j ( − ρ u i ’ u j ’ ¯ )
The k equation can be presented as:
∂ k ∂ t + U j ∂ k ∂ x j = μ t ρ S 2 − ϵ + ∂ [ 1 ρ ( μ + μ t σ k ) ∂ k ∂ x j     ] ∂ x j
The ϵ equation can be presented as:
∂ k ∂ t + U j ∂ ϵ ∂ x j = ϵ k ( C 1 μ t ρ S 2 − C 2 ϵ ) + ∂ [ 1 ρ ( μ + μ t σ ϵ ) ∂ ϵ ∂ x j     ] ∂ x j
where the μ t is the eddy viscosity obtained as:
μ t = ρ C μ k 2 ϵ
where σ k   and   σ ϵ , are the turbulent Prandtl number of k and ϵ ; C 1 , C 2 , and C μ are constant; in this article, the coefficients are determined by the experimental values σ ϵ = 1.3 ,   σ k = 1.0 ,   C 1 = 1.44 ,   C 2 = 1.92 ,   and   C μ = 0.09 . Additionally, ui is the velocity component along the direction of i, xi (i = 1, 2, 3) is the coordinate axis, p is the pressure, ρ is the density, μ is the dynamic viscosity, and t is the time.

2.3. Grid Independence Analysis

Based on ANSYS ICEM, a structured grid is used to discretize the computational domain. Since the wall function is used, the boundary mesh is required for calculation, so the boundary layer is encrypted on the wall [38]. The mesh of forebay is shown in Figure 3.
Figure 3. The grid of the forebay.
For CFD numerical simulation, the mesh quality has a great influence on the accuracy of the calculation results. So, different sizes of grids are selected to divide the model, and the number of grids is finally obtained as 97 thousand, 221 thousand, 728 thousand, 3.349 million, 4.128 million, 5.001 million, 6.341 million, 7.04 million, 8.179 million, and 12.257 million, respectively. The total hydraulic loss is selected as the characteristic parameter of grid independence analysis, and the formula to calculate the total head loss is
Δ h = P i n   -   P out ρ g
The hydraulic loss under different grid numbers is shown in Figure 4. When the grid number exceeds 7 million, the hydraulic loss is almost the same and the error is within ±2%.
Figure 4. Hydraulic loss diagrams under different grid schemes.

2.4. Boundary Condition Setting

The values of k and ε at the inlet boundary need to be given when using various k-ε models to calculate turbulence. The rough estimate is calculated according to the following formula:
k = 3 2 ( u I ) 2
ε = C u 3 4 k 3 2 l
Where k is the turbulent kinetic energy; u is the average velocity of the cross-section; and i is the turbulence intensity, which can be calculated by the relationship with the Re number. The actual turbulence intensity calculated by the empirical formula is 9.8%, and the actual average velocity is 0.178 m/s. The turbulent kinetic energy calculated by the formula is 4.54 × 10−4 m2/s2. ε is the turbulent dissipation rate; cu is usually 0.09; k is the turbulent kinetic energy of 4.54 × 10−4 m2/s2; l is the turbulent scale, which is 2.217 m, and the turbulent dissipation rate is 7.17 × 10−7 m2/s3 after substituting it into the formula.
The velocity in the outlet pool is not high, and the water surface fluctuates little. Consequently, the outlet section of the pipe is chosen as the outlet boundary which is set as average static pressure. The simulated wall includes the drainage walls, culvert walls, forebay walls, inlet sump walls, and outlet pipe walls. The wall surface condition adopts a no-slip wall in which the wall velocity is 0. Considering the actual situation, the wall roughness is set at 1.5 mm.

3. Model Experiment

As shown in Figure 5, the scale of the model is 1:8, and the simulation test is carried out from the drainage channel to the forebay and the inlet sump. The outlet of each pump is equipped with brake valves, which can change the outlet pressure to change the flow rate. The outlet pipe is connected with the measuring flume and the flow rate is measured by the full-width weir plate. After the weir, the water flows into the reservoir and is pumped into the steady flow trough by the auxiliary pump. At last, water flows into the diversion channel. This forms a water circulation system.
Figure 5. The layout of the model test.
In order to further research the flow state of the forebay, section velocity measurements and line velocity measurements are set as shown in Figure 6. A silk line is attached to the bottom of the forebay to observe the flow pattern of the bottom pool. The velocity was measured by a CSY digital display direct reading current meter.
Figure 6. The layout of the section and line velocity measurements.
In the original scheme, the flow state of the forebay was disarranged, and two strong gyre regions were formed at the bottom of the forebay, as shown in Figure 7a. The results were similar to the model experiment in the numerical simulation, as Figure 7b shows, indicating that the model reflected the prototype flow pattern well.
Figure 7. Experimental and simulated bottom laminar flow diagram. (a) Test results; (b) Numerical simulation results.
The line velocity distribution is shown in Figure 8. The red line is the result of the model test, and the green line is the result of the numerical simulation. It is found that the numerical simulation results are very similar to the experimental results in general, although the values near the bottom boundary layer are slightly different. That is because the avoidance adopted is the non-slip wall surface, so the velocity is almost zero in the extremely thin boundary layer; this influence can be ignored through the grid independence mentioned above. Thus, the reliability of numerical simulation is further illustrated.
Figure 8. Axial velocity distribution diagram of inlet sump.

4. Research Schemes

Before the scheme is set up, the head shape of the diversion pier and the width of the diversion pier are studied. The research shows that as long as the width of the diversion pier is less than 1/5 of the forebay width B, its influence on the flow pattern of the forebay is small and can be ignored. In order to meet the construction conditions, 1 m is selected in the scheme. In addition, research shows that the shape of the head of the diversion pier is semi-circular. Thus, the width of the diversion pier here is 1 m, and the shape of the head of the diversion pier is semi-circular.
In order to study the influence of geometric parameters on the flow state in the forebay, the geometric parameters are changed according to the principle of controlling variables. The parameters include layout position, contraction angle, and diversion pier length. A total of 27 schemes are designed by changing the parameters, including scheme 0 which has no rectification measures. The flow rectification scheme is shown in Figure 9.
Figure 9. Geometric parameters contraction diversion pier.
For the different layout locations, the distance between the contraction pier and the water inlet sump is set at 0.1 L, 0.15 L, and 0.2 L. Regarding different contraction angles, the angles are set at 20°, 30°, and 40°. For the length of the diversion pier, 0.3 L, 0.4 L, and 0.5 L are set as parameter references.
In Table 1, we change the contraction angle and diversion pier when the position is set to 0.1 L in schemes 1–9. In schemes 10–18, we change the contraction angle and diversion pier when the position is set to 0.15 L. In schemes 19–27, we change the contraction angle and diversion pier when the position is set to 0.2 L.
Table 1. Schemes under different distances.

5. Results and Analysis

5.1. Analysis Parameters

The normal velocity uniformity Van and the normal weighted average angle θ are taken as the main reference parameters to evaluate the flow state. Van is used to evaluate the uniformity of velocity on the section. The larger the value is, the more uniform the normal velocity distribution on the section is. θ represents the angle between the normal velocity of the section and the section, and the larger the value is, the smoother the flow. The calculation formulas are
V a n = { 1 − ∑ i = 1 n [ ( v y i c o s β + v z s i n β ) / v n − 1 ] 2 / n } × 100 %
θ = − ∑ i = 1 n ( v y i c o s β + v z i s i n β ) a c r t a n [ ( v y i s i n β + v z i c o s β ) 2 + v x i 2 / ( v y i c o s β + v z i s i n β ) ] · [ ∑ i = 1 n ( v y i c o s β + v z i s i n β ) ] − 1 + [ ∑ i = 1 n ( v y i c o s β + v z i s i n β ) · π / 2 ] · [ ∑ i = 1 n ( v y i c o s β + v z i s i n β ) ] − 1 × 100 %
Considering the purpose of the paper is to provide good inlet conditions, Section 1, Section 2 and Section 3 are selected as reference sections. The flow state of the internal flow field in the forebay is analyzed by analyzing velocity uniformity and weighted average angle of the inlet section.

5.2. Analysis of Cross-Sections

For the cross-sectional selection of each scheme, the bottom cross-sectional selected is h = 0.7 m, the middle cross-sectional selected is h = 2.1 m, and the sub-surface cross-sectional selected is h = 2.8 m. As for the original scheme, the forebay is not symmetrical and the diffusion contraction angle is not suitable for some requirements; a poor flow state is produced. The cross-section of the scheme is shown in Figure 10.
Figure 10. Flow diagram of the bottom layer (a), middle layer (b), and surface layer (c) in scheme 0.
As Figure 10 shows, an obvious large backflow area appeared at the bottom of the forebay which affected the flow state of the intake pool. Although the flow pattern of pump 2# is not so bad, the vortex appears in pump 1# and pump 3#, resulting in poor inlet conditions.
It can be found that the poor flow state of the forebay is more obvious in the bottom area. Therefore, for the cross-section analysis of the effect of the contraction diversion pier, the bottom cross-section is taken as the main analysis object. According to the principle of the control variable method, when analyzing the influence of the position of the contracting diversion pier, schemes 2, 11, and 20 are compared. These three schemes are based on an angle of 20° and length of 0.4 L, but the distance from the contraction pier to the inlet sump is 0.1 L, 0.15 L, and 0.2 L. The cross-section of the bottom area of the three schemes is shown in Figure 11.
Figure 11. Comparison of bottom streamline and velocity cloud images at different distances. (a) 0.1 L, (b) 0.15 L, and (c) 0.2 L.
As Figure 11 shows, when the distance is set to 0.2 L, there is a large vortex; when the distance is set to 0.1 L, the negative velocity area is smaller, the flow state of the forebay is relatively smooth, and the flow state of the inlet sump has a significant improvement. In conclusion, when the distance changes from 0.2 L to 0.15 L and then to 0.1 L, the flow state improves.
When analyzing the influence of the shrinkage angle of the contracting diversion pier, schemes 12, 15, and 18 are compared. These three schemes are based on a length of 0.4 L and a distance from the section of 0.15 L, but the angles are 20°, 30°, and 40°. The cross-section of the bottom area of the three schemes is shown in Figure 12.
Figure 12. Comparison of bottom streamline and velocity cloud images at different angles. (a) 20°, (b) 30°, and (c) 40°.
As Figure 12 shows, although the original reflux can be obstructed at a large contraction angle, it is easy to form a large cavity in other locations, resulting in other reflux phenomena. Therefore, the contraction angle of the contraction diversion pier is 20°.
When analyzing the influence of the length of contracting diversion pier, schemes 19, 20, and 21 are compared. These three schemes are based on an angle of 20° and a distance from the contraction pier of 0.2 L, but the lengths are 0.3 L, 0.4 L, and 0.5 L. The cross-section of the bottom area of the three schemes is shown in Figure 13.
Figure 13. Comparison of bottom streamline and velocity cloud images at different angles. (a) 0.3 L, (b) 0.4 L, and (c) 0.5 L.
As Figure 13 shows, when the length increases, the backflows at both sides of the forebay noticeably disappear. Although a small vortex is generated at the inlet, the flow state of the inlet is improved, and the backflow area of the inlet decreases.

5.3. Analysis of Vertical Section

In this paper, the inlet sump section is selected as the investigation object, and the normal velocity uniformity Van and the normal weighted average angle θ are calculated by the above formula to evaluate the improvement of the contracting diversion pier. In order to analyze the water inlet conditions of the pump, three inlet sections are selected as evaluation sections. The velocity and pressure contour map of the original section is shown as follows. The Van of pump 1# is 76.83% and the θ of pump 1# is 68.50°. The Van of pump 2# is 85.76% and the θ of pump 2# is 70.72°. The Van of pump 3# is 70.78% and the θ of pump 3# is 68.33°. By comparison, the inlet flow state of pump 2# is the best. It can also be seen from Figure 14 that large backflow occurs in pump 1# and pump 3#, and the flow velocity distribution of pump 2# is more uniform. According to Figure 15, the bottom pressure is less than the upper pressure, which is one of the reasons for the backflow.
Figure 14. Contour map of the inlet section velocity in the original scheme 0.
Figure 15. Contour map of the inlet section pressure in the original scheme 0.
The normal velocity uniformity Van and the normal weighted average angle θ of 27 schemes are obtained. The schemes that improved significantly and those that declined are shown in Table 2
Table 2. Numerical analysis of inlet section under different schemes.
As Table 2 shows, scheme 1, with the distance from the contraction pier to the sump of 0.1 L, the contraction angle of 20°, and 0.3 L length has the best rectification effect. Schemes 1, 2, 4, 7, 10, and 19 have a positive influence on the flow state but schemes 9, 18, and 27 have a negative influence on the flow state. The velocity and pressure contour map for the best scheme, scheme 1, is shown as follows.
As Figure 16 shows, compared with scheme 0, the negative velocity in the section of pump 1# and the section of pump 3# is significantly reduced, the size of the reflux zone is reduced, and the flow state is improved. According to Figure 15 and Figure 17, the inlet section pressure in scheme 1 is larger than the inlet section pressure in scheme 0, which means hydraulic loss of the forebay in scheme 1 is less than that in scheme 0. Overall, scheme 1 is better than the original scheme.
Figure 16. Contour map of inlet section velocity in the original scheme 1.
Figure 17. Contour map of inlet section pressure in scheme 1.
In order to better analyze the internal flow characteristics of water flow in the forebay, representative schemes 0, 1, and 27 were selected based on the data in Table 2, and the forebay was divided into 6 sections. Section 1 was the inlet section of the forebay, Section 6 was the outlet section of the forebay, and the spacing of each section was 1/5 L, as shown in Figure 18.
Figure 18. Schematic diagram of a characteristic section of the forebay.
As shown in Figure 19a, in scheme 0, due to the existence of the culvert isolation pier, the middle flow velocity of Section 1 is faster than the flow velocity on both sides. Additionally, when the diffusion angle of the forebay enlarges, the water flow on the side wall of Section 2 back flowed and the mainstream was clearly concentrated in the middle. With the development of backflow, there are large-scale reflux areas on both sides of Section 3, accounting for about half of the area of the section. The flow state in the forebay is improved to some extent after the bottom slope rectification. Therefore, it can be seen that the area of the reflux zone on both sides of Section 4 is reduced. However, with the irregular contraction, there is still a backflow zone in the middle and on both sides of Section 5. At the same time, there is still a negative velocity zone in Section 6, and the velocity distribution is not uniform.
Figure 19. Flow rate distribution diagram of the forebay. (a) Scheme 0, (b) Scheme 1, and (c) Scheme 27.
As shown in Figure 19b, in scheme 1, the velocity distribution of Section 1 is almost the same as that of scheme 0. There are reflux zones in the side walls and the middle bottom of Section 2 and Section 3, and the mainstream flow velocity is significantly lower than that of scheme 0. However, after passing the diversion pier and bottom slope, the flow in the forebay is notably improved, and the area of negative flow velocity in Section 4 disappears completely. Under the action of the diversion pier, the flow velocity distribution of Section 5 and Section 6 is significantly more uniform than that of scheme 0, providing a better inlet flow pattern for the intake pool.
As shown in Figure 19c, in scheme 27, the velocity distribution of Section 1 has no obvious change. Although the backflow zone at the side walls of Section 2 and Section 3 is completely absent, a large backflow zone exists at the middle bottom layout. There is a backflow zone at the bottom right of Section 4, and the middle part is basically filled with a negative flow rate and low-speed flow. In the middle part of Section 5, the negative velocity disappeared under the contraction of the diversion pier, and the reflux area increased perceptibly with the increase in the flow area. After the development of the backflow, the flow state of Section 6 is worse than that of scheme 0, and the backflow area is noticeably larger.
Therefore, a suitably arranged diversion pier (scheme 1) can improve the flow state in the forebay, eliminate the large-scale backflow area, and improve the uniformity of velocity distribution at the outlet section. However, once the diversion pier is arranged improperly (scheme 27), the flow state in the forebay will deteriorate, with a large backflow area, and the uniformity of velocity distribution at the outlet section will be reduced, providing poor inlet conditions for the pump.
In order to quantitatively analyze the inlet flow state of the coastal pumping station, the turbulent kinetic energy, Van, and θ of the forebay section and the inlet sump section were calculated [39], and the results were plotted in Figure 20.
Figure 20. Trend diagram of Van, θ, and the turbulent kinetic energy of characteristic sections. (a) Turbulent kinetic energy, (b) Normal velocity uniformity, and (c) Normal weighted average angle.
From the perspective of turbulent kinetic energy, in scheme 0, the turbulent kinetic energy essentially shows an increasing trend with the development of water flow, and the turbulent kinetic energy at the inlet section of the pool is 0.20%. In scheme 1, the turbulent kinetic energy showed a ‘W’ shape with the development of water flow (a decreasing, increasing, decreasing, and increasing trend), and the maximum value was 0.16% in Section 3 and 0.11% in the inlet section. In scheme 27, the turbulent kinetic energy shows an n-shaped law (increasing, decreasing, and increasing trend) with the development of water flow. The maximum value of turbulent kinetic energy is 0.46% in Section 3 and the turbulent kinetic energy is 0.23% in the inlet section.
From the perspective of Van and the development of water flow, Van showed a ‘V-shaped’ pattern (decreasing first and then increasing). Van was 77.79% at the inlet section of scheme 0, 91.66% at the inlet section of scheme 1, and 48.65% at the Van of scheme 27.
From the perspective of θ, the θ shows a ‘W’ shape law with the development of water flow. The inlet section θ of scheme 0, scheme 1, and scheme 27 are 69.18°, 81.18°, and 64.01°.

6. Conclusions

In this research, a CFD numerical simulation is used to explore the influence of the distance from the contraction pier to the inlet sump, the contraction angle, and the length of the pier on the flow state. Using the control variable method, the simulation is carried out by changing three geometric dimensions. When comparing these schemes, it can be seen that the three factors have different degrees of influence on the flow state, leading to the following conclusions:
(1) For the forebay with a large diffusion angle, a large-scale backflow area exists on both sides of the forebay, and the distribution of velocity in the forebay is not uniform, which leads to poor inlet conditions.
(2) A contraction diversion pier can be used to concentrate the flow. In the area where reflux is formed, the contraction diversion guides the water flow along the diversion pier wall. When the retractable diversion pier is located in the middle of the reflux zone, the water backflow is effectively reduced, the flow state is improved, and the inlet condition of the pump is optimized.
(3) Concerning the geometric parameters of the contraction diversion pier, the recommendations are a 0.1 L distance from the contraction pier to the sump, a contraction angle of 20°, and a pier length of 0.3 L. Under these parameters, the flow state of the forebay is optimal and the inflow velocity is the most uniform.
(4) Several schemes confirmed that a contraction angle of 40° and length of 0.4 L should be avoided when designing the contraction diversion pier. In this case, the flow state will be worse than before, regardless of the distance from the contraction pier to the inlet sump.

Author Contributions

Conceptualization, W.X. and L.C.; methodology, W.X. and K.D.; formal analysis, W.X. and L.Y.; writing—original draft, W.X.; writing—review and editing, W.X., Y.G. and J.Z.; and supervision, L.C. and K.D. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Natural Science Foundation of China (grant no. 52279091) and the Jiangsu Province Postgraduate Research Innovation Plan (grant no. KYCX22_3491).

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors are grateful to the reviewers for their comments to improve the quality of this paper and would also like to thank the editors for their help with this paper.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Luo, C.; Liu, H.; Shi, W.; Cheng, L.; Qi, W.J. Numerical simulation of flow pattern in forebay of double lateral pumping station. China Rural. Water Hydropower 2020, 11, 121–128. [Google Scholar]
  2. Luo, C.; Lei, S.H.; Yuan, Y.; Cheng, L.; Du, K. Numerical simulation research on inlet flow pattern of small sluice station lateral pumping station. J. Drain. Irrig. Mach. Eng. 2021, 39, 797–803. [Google Scholar]
  3. Zhao, M.M.; Jia, J.D.; Qi, W.J.; Qin, J.H.; Liang, J.D.; Yang, F. Numerical simulation of division pier rectifying flow in forebay of combined sluice-coastal pumping station. China Rural. Water Hydropower 2018, 4, 125–130. [Google Scholar]
  4. Yang, X.; Xi, B.; Lu, R.; Zhang, C.H.; Duan, Y.F.; Zheng, Y.Z. Influence of hollow rectifying sill on flow pattern in forebay of side-inlet pumping station. Water Resour. Power 2020, 38, 161–164+180. [Google Scholar]
  5. Zhou, L.; Wang, W.H.; Hang, J.W.; Shi, W.D.; Yan, H.; Zhu, Y. Numerical investigation of a high-speed electrical submersible pump with different end clearances. Water 2020, 12, 1116. [Google Scholar] [CrossRef] [Scilit]
  6. Spence, R.; Amaral-Teixeira, J. Investigation into pressure pulsations in a centrifugal pump using numerical methods supported by industrial tests. Comput. Fluids 2008, 37, 690–704. [Google Scholar] [CrossRef] [Scilit]
  7. Tang, S.N.; Yuan, S.Q.; Zhu, Y. Data preprocessing techniques in convolutional neural network based on fault diagnosis towards rotating machinery. IEEE Access 2020, 8, 149487–149496. [Google Scholar] [CrossRef] [Scilit]
  8. Lu, W.G.; Sun, C.G.; Xu, B.; Sun, B. Numerical simulation study on rectification schemes of the forebay of pumping station. Water Resour. Power 2020, 38, 90–93. [Google Scholar]
  9. Song, W.W.; Pang, Y.; Shi, X.H.; Xu, Q. Study on the rectification of forebay in pumping station. Math. Probl. Eng. 2018, 2018, 2876980. [Google Scholar] [CrossRef] [Scilit]
  10. Ansar, M.; Nakato, T. Experimental study of 3D pump-intake flows with and without cross flow. J. Hydraul. Eng. 2001, 127, 825–834. [Google Scholar] [CrossRef] [Scilit]
  11. Kernan, R.; Liu, X.; McLoone, S.; Fox, B. Demand side management of an urban water supply using wholesale electricity price. Appl. Energy 2017, 189, 395–402. [Google Scholar] [CrossRef] [Scilit]
  12. Xu, C.D.; Wang, R.R.; Liu, H.; Zhang, R.; Wang, M.Y.; Wang, Y. Flow pattern and anti-silt measures of straight-edge forebay in large coastal pumping stations. Int. J. Heat Technol. 2018, 36, 1130–1139. [Google Scholar] [CrossRef] [Scilit]
  13. Yang, F.; Zhang, Y.Q.; Liu, C.; Wang, T.L.; Jiang, D.J.; Jin, Y. Numerical and experimental investigations of flow pattern and anti-vortex measures of forebay in a multi-unit pumping station. Water 2021, 13, 935. [Google Scholar] [CrossRef] [Scilit]
  14. Wang, H.D.; Li, C.G.; Lu, S.J.; Song, L.L. The flow patterns and sediment deposition in the forebay of a forward-intake pumping station. Phys. Fluids 2022, 34, 8. [Google Scholar] [CrossRef] [Scilit]
  15. Xi, W.; Lu, W.G.; Wang, C.; Xu, B. Optimization of the hollow rectification sill in the forebay of the coastal pumping station based on the PSO-GP collaborative algorithm. Shock. Vib. 2021, 2021, 6618280. [Google Scholar]
  16. Lin, W.Q.; Zhang, Q.; Yang, N.; Li, G.J. Flow state analysis and flow rectifying optimization of pump-front tank in wastewater treatment plant. Urban Roads Bridges Flood Control 2017, 5, 144–146+15. [Google Scholar]
  17. Li, Z.X.; Feng, J.G.; Qian, S.T.; Xu, H. Optimization of rectification bottom sill parameters in drainage pumping stations. Trans. Chin. Soc. Agric. Eng. 2021, 37, 56–63. [Google Scholar]
  18. Gao, C.C.; Zeng, X.L.; Xie, K.Y.; Tang, L.J. Combined rectification scheme and Verification of pump intake sump in ultra-low water level and its verification. Trans. Chin. Soc. Agric. Eng. 2017, 33, 101–108. [Google Scholar]
  19. Ying, J.W.; Yu, X.D.; He, W.; Zhang, J. Volume of fluid model-based flow pattern in forebay of coastal pumping station and combined rectification scheme. J. Drain. Irrig. Mach. Eng. 2020, 38, 476–480+493. [Google Scholar]
  20. Luo, C.; Cheng, L.; Liu, C. Numerical simulation of mechanism for sill rectifying flow in pumping station intake. J. Drain. Irrig. Mach. Eng. 2014, 2, 393–398. [Google Scholar]
  21. Zhao, H.R.; Wang, F.J.; Wang, C.Y. Study on the characteristics of horn-like vortices in an axial flow pump impeller under off-design conditions. Eng. Appl. Comput. Fluid Mech. 2021, 15, 13–28. [Google Scholar] [CrossRef] [Scilit]
  22. Xia, C.Z.; Cheng, L.; Zhao, G.F.; Yu, L.; Wu, M.T.; Xu, W.T. Numerical simulation of flow pattern in forebay of coastal pumping station with single row of square columns. Adv. Sci. Technol. Water Resour. 2017, 37, 53–58. [Google Scholar]
  23. Zhou, M.; Zhou, C.F.; Zhou, Y.X.; Xu, L.; Cheng, L. Influence of circular columns on flow pattern in side-intake forebay of pumping station and rectification mechanism. J. Yangzhou Univ. 2020, 23, 73–78. [Google Scholar]
  24. Li, Y.Y.; Guo, P.C.; Sun, L.G.; Zhang, H. Numerical analysis on influence of vertical column on flow pattern in forebay and intake of large pumping station. J. Drain. Irrig. Mach. Eng. 2021, 39, 929–936. [Google Scholar]
  25. Xu, X.A.; Wang, F.J.; Zi, D. Cross vortex baffles for rectification of flows in intake field of a large-scale pumping station. J. Hydroelectr. Eng. 2018, 37, 101–110. [Google Scholar]
  26. Xu, R.L.; Xu, L.; Xu, R.L.; Lu, L.G.; Zhang, Z. Optimization design of rectifying flow of column array in pressure forebay with extra-large diffusion angle of a pumping station. Water Resour. Hydropower Eng. 2021, 52, 134–145. [Google Scholar]
  27. Zhu, W.J. Control and improvement of water flow characteristics in the front water inlet of small and medium-sized pumping stations by using vertical columns. Tech. Superv. Water Resour. 2019, 2, 170–173. [Google Scholar]
  28. Hou, Y.S. Numerical simulation analysis of flow pattern in forebay of drainage pumping station in northern plains of China. Water Resour. Plan. Des. 2019, 3, 111–114. [Google Scholar]
  29. Liu, C.; Chen, Q.; Jiang, J.; Liu, Y.M. Experimental research on the influence of diversion pier on the flow field of pumping station forebay. China Rural. Water Hydropower 2018, 4, 112–118. [Google Scholar]
  30. Jia, J.D.; Zhou, J.R.; Zhao, M.M.; Qin, J.H.; Fu, C.K.; Jia, L. Impact of wedge-shaped Guide Piers on Rectification Effect of Large Diffusion Angle Forebay for Pumping Station. Water Resour. Power 2019, 37, 88–91. [Google Scholar]
  31. Yang, F.; Zhang, Y.; Liu, C.; Wang, T.; Jiang, D.; Jin, Y. Numerical Investigations of Flow Pattern and Anti-Vortex Measures of the Pumping Station Forebay. Master’s Thesis, Yangzhou University, Yangzhou, China, May 2022. [Google Scholar]
  32. Zhou, J.R.; Zhao, M.M.; Wang, C.; Gao, Z.J. Optimal design of diversion piers of lateral intake pumping station based on orthogonal test. Shock. Vib. 2021, 2021, 6616456. [Google Scholar] [CrossRef] [Scilit]
  33. Zhang, C.C.; Zhou, C.F.; Zhou, Y.X.; Xu, L.; Cheng, L. Analysis of geometric parameters of Y-shaped diversion piers on flow pattern in the forebay of the side-intake coastal pumping station. South North Water Transf. Water Sci. Technol. 2020, 18, 192–200. [Google Scholar]
  34. Xu, B.; Gao, S.; Xia, H.; Lu, W.G. Influence of geometric parameters of perforated diversion pier on flow-rectifying effect in forebay of sluice-coastal pumping station project. J. Yangtze River Sci. Res. Inst. 2019, 36, 58–62. [Google Scholar]
  35. Xu, B.; Zhang, C.C.; Li, Z.C.; Gao, S.; Bi, C. Using CFD model to analyze the influence of geometric parameters of diversion piers on water flow in sluice station. J. Irrig. Drain. 2019, 38, 115–122. [Google Scholar]
  36. Constantinescu, G.S.; Patel, V.C. Role of turbulence model in prediction of pump-bay vortices. J. Hydraul. Eng. 2000, 126, 387–391. [Google Scholar] [CrossRef] [Scilit]
  37. Kim, H.R.; Kim, S.; Kim, M.; Park, S.H.; Min, J.K.; Ha, M.Y. Numerical study of fluid flow and convective heat transfer characteristics in a twisted elliptic tube. J. Mech. Sci. Technol. 2016, 30, 719–732. [Google Scholar] [CrossRef] [Scilit]
  38. Dehtyriov, D.; Hourigan, K.; Thompson, M.C. Direct numerical simulation of a counter-rotating vortex pair interacting with a wall. J. Fluid Mech. 2020, 884, A36. [Google Scholar] [CrossRef] [Scilit]
  39. Jiao, W.X.; Chen, H.J.; Cheng, L. Experimental study on flow evolution and pressure fluctuation characteristics of the underwater suction vortex of water jet propulsion pump unit in shallow water. Ocean Eng. 2022, 266, 112569. [Google Scholar] [CrossRef] [Scilit]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.