Skip to Content
  • Article
  • Open Access

26 November 2026

12 Pages

Arterial Stiffness in Patients with Non-Arteritic Anterior Ischemic Optic Neuropathy: A Case–Control Study Using Oscillometric Pulse Wave Analysis

,
,
,
,
and
1
Department of Cardiology, Ondokuz Mayıs University, Samsun 55200, Turkey
2
Department of Cardiology, Samsun City Hospital, Samsun 55080, Turkey
3
Department of Ophthalmology, Ondokuz Mayıs University, Samsun 55200, Turkey
4
Department of Family Medicine, Ondokuz Mayıs University, Samsun 55200, Turkey
J. Clin. Med.2026, 15(23), 9272;https://doi.org/10.3390/jcm15239272 
(registering DOI)
This article belongs to the Special Issue Arterial Stiffness: A Key Determinant of Cardiovascular Risk in Clinical Medicine

Abstract

Background: Systemic vascular factors are implicated in non-arteritic anterior ischemic optic neuropathy (NAION), but few studies have examined arterial stiffness. We compared estimated aortic pulse wave velocity (PWV) and augmentation index (AIx@75) between patients with NAION and controls. Methods: In this prospective, single-center case–control study (April–October 2026), 46 patients with NAION and 50 controls without NAION recruited from the cardiology outpatient clinic underwent oscillometric pulse wave analysis (Mobil-o-Graph, ARCSolver algorithm), transthoracic echocardiography and laboratory evaluation. Participants with coronary artery disease, atrial fibrillation or heart failure with reduced ejection fraction were excluded. Associations were examined with logistic regression adjusted for a pre-specified set of variables: age, sex, systolic blood pressure, diabetes and hypertension, with Firth correction and bootstrap internal validation. Results: Patients were older than controls (median 64.0 vs. 58.0 years), with similar brachial systolic pressure. Estimated PWV (10.2 ± 1.3 vs. 8.0 ± 0.9 m/s) and AIx@75 (31.8 ± 7.3% vs. 23.5 ± 8.5%) were higher in NAION (both p < 0.001). After adjustment for age, sex and systolic pressure, the mean PWV difference was 1.75 m/s (95% CI 1.44–2.07). Because the device derives PWV partly from age, odds ratios for PWV increased after age adjustment and were not interpreted as effect sizes; AIx@75 remained associated with NAION in the fully adjusted model (OR per 1% 1.12, 1.05–1.19). In-sample discrimination of PWV alone was an AUC of 0.906 (0.834–0.959). Conclusions: In this case–control sample, estimated aortic PWV and AIx@75 were higher in patients with NAION. PWV was algorithm-derived and the sample was small, so the findings need confirmation with reference-standard measurements and prospective studies before any causal or clinical conclusion is drawn.

1. Introduction

Non-arteritic anterior ischemic optic neuropathy (NAION) is the most common acute optic neuropathy in middle-aged and older adults. It typically presents with sudden, painless loss of vision or a visual field defect accompanied by optic disc edema [1,2]. Systemic vasculopathic conditions, including hypertension, hyperlipidemia, diabetes mellitus and atherosclerosis, are frequently associated with the disease [3,4]. Among ocular factors, a small, crowded optic disc with little or no cup (the “disc at risk”) is the best established [5,6].
The optic nerve head is supplied mainly by the short posterior ciliary arteries, and its watershed zones are thought to be vulnerable to falls in perfusion pressure [7,8]. Proposed triggers include nocturnal arterial hypotension, vasospasm, local arteriosclerosis and, less commonly, thrombosis or embolism, but no single mechanism has been established [1,9].
Arterial stiffness reflects reduced elasticity of the large arteries. It increases the transmission of pulsatile pressure and flow into low-resistance microvascular beds and predicts cardiovascular events independently of conventional risk factors [10,11]. In the brain, increased stiffness is associated with reduced cerebral blood flow, small-vessel disease and endothelial dysfunction [12,13]. Carotid–femoral PWV measured by tonometry is the reference method [10]. Single-cuff oscillometric devices provide an estimate of aortic PWV and central hemodynamics from the brachial waveform [14,15], but their PWV estimate is largely determined by age and systolic blood pressure [16,17].
Previous studies in NAION have reported impaired flow-mediated dilation [18], increased carotid intima–media thickness and plaque burden [19,20], and higher atherogenic lipid indices [21]. A recent study of ocular vascular ischemia that included 28 patients with NAION measured PWV but reported the largest stiffness differences in retinal vein occlusion [22]. Arterial stiffness has also been linked to glaucoma and retinal vein occlusion [23,24]. Few studies have compared PWV and wave reflection between patients with NAION and controls. We therefore compared estimated aortic PWV and AIx@75 between patients with NAION and controls, with adjustment for pre-specified clinical confounders.

2. Materials and Methods

2.1. Study Design and Participants

This prospective, single-center case–control study was conducted at Ondokuz Mayıs University Faculty of Medicine between April 2026 and October 2026, in accordance with the Declaration of Helsinki. It was approved by the Clinical Research Ethics Committee of Ondokuz Mayıs University (decision no. OMU KAEK 2026/574, dated 24 April 2026), before recruitment began. Written informed consent was obtained from all participants. This study is independent of the earlier work from our institution on atherogenic indices in NAION [21] and shares no participants or data with it. The study is reported in accordance with the STROBE guideline for case–control studies [25].
Patients with newly diagnosed NAION were enrolled consecutively at the neuro-ophthalmology unit of the Department of Ophthalmology. All presented with acute, painless, unilateral (rarely bilateral) visual loss and optic disc edema. Each underwent a complete ophthalmological examination, including optical coherence tomography, fundus fluorescein angiography and visual field testing. To exclude other causes of optic disc edema, brain and orbital magnetic resonance imaging, carotid Doppler ultrasonography, echocardiography, superficial ultrasonography of the temporal artery and relevant specialty consultations were performed. Only patients with a definite diagnosis of NAION were enrolled. Eight patients with suspected NAION in whom a definite diagnosis could not be established and who were therefore referred for hematology and genetic consultation were excluded at the outset, before enrollment (Figure 1). Vascular measurements were performed a median of 5 days (IQR 4–7) after symptom onset, before any change in antihypertensive treatment.
Figure 1. Flowchart of the study population. Eight patients with suspected NAION were excluded before enrollment because a definite diagnosis could not be established (referred for hematology and genetic consultation). Each excluded participant is counted once, under the main reason for exclusion. HFrEF/HFmrEF, heart failure with reduced or mildly reduced ejection fraction (LVEF < 50%).
Controls were consecutive individuals aged ≥ 40 years attending the cardiology outpatient clinic of our hospital during the same period, with no history of acute visual loss or impaired visual function and no ocular disease other than refractive error. Controls were not randomly sampled or individually matched. No a priori sample size calculation was performed; all eligible patients during the study period were enrolled.
Inclusion required an age < 80 years. Exclusion criteria for both groups were: coronary artery disease; cerebrovascular disease; peripheral arterial disease; heart failure with reduced or mildly reduced ejection fraction (LVEF < 50%); atrial fibrillation; chronic renal failure; pregnancy; history of alcohol abuse; ocular pathology other than refractive error; elevated inflammatory markers, defined as an erythrocyte sedimentation rate (ESR) ≥ 50 mm/h and/or C-reactive protein (CRP) ≥ 10 mg/L, corresponding to the inflammatory marker thresholds of the 2022 American College of Rheumatology/EULAR classification criteria for giant cell arteritis [26]; an uncertain diagnosis of NAION requiring further hematological or genetic evaluation; ambiguity in the differential diagnosis between giant cell arteritis and NAION, or confirmed giant cell arteritis; and failure to obtain a valid pulse wave recording (device quality indicator below the manufacturer’s threshold in three consecutive attempts). The participant flow is shown in Figure 1.

2.2. Definitions

Hypertension was defined as a previous physician diagnosis of hypertension, current use of antihypertensive medication, or office blood pressure ≥ 140/90 mmHg on repeated cuff measurements [27]. Because participants with previously diagnosed, treated hypertension were included, office blood pressure could be within the normal range in individuals classified as hypertensive. Diabetes mellitus was defined by American Diabetes Association criteria or use of glucose-lowering treatment [28]. Hyperlipidemia was defined as a previous diagnosis of dyslipidemia, use of lipid-lowering therapy, or LDL-C and/or triglyceride levels above the thresholds recommended for the individual’s cardiovascular risk category in the ESC/EAS guidelines [29]. Obstructive sleep apnea syndrome (OSAS) required a polysomnography-confirmed diagnosis. Heart failure with preserved ejection fraction (HFpEF) was defined as clinical heart failure with LVEF ≥ 50%.

2.3. Laboratory and Office Blood Pressure Measurements

Venous blood was collected in the morning for biochemical analysis at the hospital’s Clinical Testing Center. ESR (mm/h), CRP (mg/L), glucose and lipids were measured on an Abbott Architect c4000 system (Abbott Laboratories, Abbott Park, IL, USA) and creatinine on a Roche Cobas 8000 platform (Roche Diagnostics GmbH, Mannheim, Germany), following the manufacturers’ protocols with routine quality control. Participants were asked to fast overnight; however, fasting status could not be verified in all participants. Office blood pressure was measured in the cardiology outpatient clinic with a cuff-based sphygmomanometer (Honsun, Nantong, China) using an appropriately sized cuff, in the sitting position after 10 min of rest.

2.4. Pulse Wave Analysis

All hemodynamic measurements were made with a single Mobil-o-Graph PWA monitor (I.E.M. GmbH, Stolberg, Germany) by a technician blinded to group allocation. Measurements were performed in a quiet room at 22–24 °C, with the participant seated at rest for at least 5 min. An appropriately sized cuff was placed on the left upper arm in most cases, and occasionally on the right. The device first measured brachial blood pressure oscillometrically, then re-inflated to diastolic pressure level and recorded brachial pulse waves for about 10 s. The ARCSolver algorithm (HMS Client-Server software 5.2.3) reconstructed the aortic pressure waveform using a transfer function, with calibration to brachial systolic and diastolic pressure. All recordings in both groups were made with the same device, the same software version and identical device settings. Aortic PWV was estimated from the waveform characteristics, age and central systolic pressure; it is therefore an algorithm-derived estimate and not a directly measured carotid–femoral PWV. The augmentation index was normalized to a heart rate of 75 bpm (AIx@75). Stroke volume, cardiac output and total vascular resistance (TVR, s·mmHg/mL) were obtained from the device. Age and sex were entered for each participant at each examination. Three measurements were obtained and the mean of valid recordings was used; a representative device report is shown in Supplementary Figure S2. Mean arterial pressure (MAP) was calculated as (SBP + 2 × DBP)/3 from the device brachial reading.

2.5. Echocardiography

Transthoracic echocardiography was performed with a Philips Epiq CVx/Affiniti 70 system (Philips Ultrasound, Inc., Bothell, WA, USA) with an X5-1/S5-1 matrix phased-array transducer. LVEF was calculated using Simpson’s biplane method of disks from manually traced end-diastolic and end-systolic endocardial borders in the apical four- and two-chamber views, excluding papillary muscles and trabeculations. Left atrial (LA) size was measured as the anteroposterior diameter in the parasternal long-axis view at end-systole. LA area and volume were not measured.

2.6. Statistical Analysis

Analyses used Python for Firth regression and bootstrap procedures. Normality was assessed with the Shapiro–Wilk test. Normally distributed variables are presented as mean ± SD and compared with Welch’s t-test. Non-normal variables are presented as median (IQR) and compared with the Mann–Whitney U test, with Hodges–Lehmann differences and bootstrap 95% CIs. Categorical variables are presented as n (% within group) and compared with the χ2 or Fisher’s exact test. There were no missing data in the final dataset.
The association of PWV with NAION was examined with logistic regression using a pre-specified adjustment set chosen for clinical relevance rather than univariable significance: Model 1, unadjusted; Model 2, age and sex; Model 3, age, sex, device brachial SBP, diabetes mellitus and hypertension. With 46 events, Model 3 had about 7.7 events per parameter. AIx@75 was analyzed in separate models with the same covariates because of its correlation with PWV. Firth penalized-likelihood estimates [30] are reported alongside maximum-likelihood estimates to reduce small-sample bias. Collinearity was assessed with variance inflation factors (VIFs), linearity of the logit with Box–Tidwell terms, influence with Cook’s distance, and calibration with the Hosmer–Lemeshow test. The correlation matrix of age and hemodynamic variables is given in Supplementary Table S1. Discrimination is reported as the area under the receiver operating characteristic curve (AUC) with 2000-sample bootstrap 95% CIs. The multivariable AUC was internally validated with 500 bootstrap resamples (optimism correction). The age-, sex-, and SBP-adjusted mean PWV difference was estimated by analysis of covariance (ANCOVA). Because the device algorithm incorporates age and blood pressure into the PWV estimate, this adjusted mean difference was taken as the main effect measure for PWV, and the logistic models for PWV were regarded as supportive analyses. Sensitivity analyses excluded participants with HFpEF and with OSAS, and added smoking and BMI to Model 3. Two-sided p < 0.05 was considered significant. In a post hoc sensitivity power analysis, the available sample (46 cases and 50 controls) provided 80% power (two-sided α = 0.05) to detect a standardized difference of 0.58 SD.

3. Results

Of 127 individuals assessed for eligibility (63 with suspected NAION and 64 controls), 8 patients with suspected NAION were excluded at the outset because a definite diagnosis could not be established and they were referred for hematology and genetic consultation. Of the remaining 119 individuals enrolled (55 with NAION and 64 controls), 23 were excluded (Figure 1). The final sample comprised 46 patients with NAION and 50 controls.
Patients were older than controls (median 64.0 vs. 58.0 years, p = 0.007) and had slightly higher BMI and office diastolic pressure. Sex distribution, smoking, hypertension, hyperlipidemia and diabetes did not differ significantly (Table 1). Device brachial SBP (127.8 ± 12.2 vs. 125.6 ± 17.0 mmHg) and MAP were similar between groups.
Table 1. Characteristics of participants by group.
Estimated aortic PWV was higher in patients with NAION (10.2 ± 1.3 vs. 8.0 ± 0.9 m/s; difference 2.2 m/s, 95% CI 1.8–2.7), as was AIx@75 (31.8 ± 7.3% vs. 23.5 ± 8.5%; difference 8.3%, 95% CI 5.1–11.5). Stroke volume, cardiac output and LA diameter were higher, and heart rate lower, in patients. LVEF, TVR, inflammatory markers, lipids, hemoglobin and creatinine did not differ; median glucose was lower in patients (Table 1), although this difference should be interpreted with caution because fasting status could not be verified in all participants. After adjustment for age, sex and SBP, the mean PWV difference was 1.75 m/s (95% CI 1.44–2.07). Individual PWV values plotted against age and device-measured SBP are shown in Supplementary Figure S1.
In logistic regression, PWV was associated with NAION in all models (Table 2). In the fully adjusted model, the Firth OR per 1 m/s was 13.97 (95% CI 4.90–39.79). The OR increased from 4.72 in the unadjusted model to 13.97 after full adjustment; this increase does not indicate a stronger association. Because the device derives PWV partly from age (r = 0.70; Supplementary Table S1), the PWV coefficient in age-adjusted models reflects only the part of the estimate not explained by age. This component varies less than PWV itself, so a 1 m/s difference represents a larger contrast and yields a larger OR. For the same reason, age acquired an inverse coefficient (OR 0.84, 95% CI 0.75–0.94): at a given PWV, a younger participant has a larger age-independent component. The difference between the maximum-likelihood and Firth estimates (24.46 vs. 13.97) and the wide confidence interval also show that the size of the adjusted OR is unstable in this sample. We therefore did not interpret the adjusted ORs for PWV as effect sizes and regard the adjusted mean difference (1.75 m/s, 95% CI 1.44–2.07) as the main effect measure. Results were similar after excluding participants with HFpEF or OSAS and after adding smoking and BMI. AIx@75, which is not estimated from age, was independently associated with NAION, and its OR changed little across models (Firth OR per 1% was 1.14, 1.13 and 1.12 in Models 1–3; 95% CI 1.05–1.19 in Model 3). VIFs were ≤ 3.2, no separation was present and the largest Cook’s distance was 0.22; calibration was imperfect (Hosmer–Lemeshow p = 0.015).
Table 2. Association of estimated aortic PWV (per 1 m/s) and AIx@75 (per 1%) with NAION.
In ROC analysis, PWV alone gave an in-sample AUC of 0.906 (95% CI 0.834–0.959); a cut-off of 9.5 m/s gave a sensitivity of 76.1% and a specificity of 92.0%. For AIx@75 the AUC was 0.761 (0.663–0.852) (Figure 2). The fully adjusted model had an apparent AUC of 0.961 and an optimism-corrected AUC of 0.943. These values describe discrimination between selected cases and controls and do not represent screening or predictive performance.
Figure 2. Receiver operating characteristic curves for estimated aortic PWV and AIx@75 in discriminating patients with NAION (n = 46) from controls (n = 50). AUCs are in-sample values with bootstrap 95% CIs and do not represent screening performance.

4. Discussion

In this case–control study, patients with NAION had higher estimated aortic PWV and AIx@75 than controls. The differences persisted after adjustment for age, sex, systolic blood pressure, diabetes and hypertension, and persisted with Firth correction and in sensitivity analyses. Stroke volume, cardiac output and LA diameter were also higher in patients.
How PWV was obtained affects the interpretation of these findings. The Mobil-o-Graph estimates aortic PWV from the brachial waveform together with age and central systolic pressure, and its estimate is largely explained by age and systolic blood pressure [16,17]. Patients in our sample were about 5 years older than controls, so part of the crude PWV difference reflects age. For the same reason, adjustment for age inflates the odds ratio for PWV and gives age an inverse coefficient: once age is in the model, the PWV term carries only the age-independent part of the estimate. This is a property of the measurement, not evidence of a stronger association or of a protective effect of age, and it makes the adjusted odds ratios unstable. We therefore regard the adjusted mean difference of 1.75 m/s as the more interpretable effect measure. AIx@75 reflects wave reflection rather than an age-based estimate and was independently higher in patients, with odds ratios that changed little after adjustment, which points to altered arterial hemodynamics. AIx values from different devices are not interchangeable [31], and our results should be compared only with studies using similar methods.
Our results are consistent with earlier evidence of systemic vascular involvement in NAION, including impaired flow-mediated dilation [18], increased carotid intima–media thickness and plaque [19,20], and adverse atherogenic lipid ratios [21]. In a recent study of ocular vascular ischemia, PWV differences were most marked in retinal vein occlusion rather than NAION [22]; differences in the comparison groups and in measurement methods may explain this. Arterial stiffness has also been associated with glaucoma and retinal vein occlusion [23,24].
Several mechanisms could link arterial stiffness with NAION, but our study was not designed to test them. Stiffer large arteries transmit more pulsatile energy into low-resistance microvascular beds [11,32], and in the brain this is associated with reduced blood flow and small-vessel disease [12]. The optic nerve head is supplied by the short posterior ciliary arteries with watershed zones between their territories [7,8]. A combination of a crowded disc, impaired autoregulation and altered pulsatile load could, in principle, lower the threshold for ischemia. Testing these hypotheses will require physiological studies of the ocular circulation.
Nocturnal arterial hypotension has long been proposed as a trigger of NAION [33], although a recent study from our center observed no significant association between hypotensive episodes and NAION [34]. Nocturnal blood pressure was not measured in this study, so the two hypotheses cannot be compared. The two mechanisms could also coexist in the same patient.
The higher stroke volume and cardiac output in patients were derived from the same oscillometric device and are model-based estimates. Their relevance to NAION is uncertain, and we did not include them in the adjusted models because they are mathematically related (cardiac output = stroke volume × heart rate). The larger LA diameter in patients should also be interpreted cautiously, because linear dimensions may not reflect true atrial remodeling [35].
This study has limitations. First, it is a single-center case–control study with vascular measurement after NAION onset, so temporality and causality cannot be inferred. Second, PWV was estimated by a single-cuff oscillometric algorithm that partly incorporates age and blood pressure, rather than measured by carotid–femoral tonometry; adjusted odds ratios for PWV are therefore inflated and unstable and were not interpreted as effect sizes, and the adjusted mean difference is the more interpretable measure. A reference-standard PWV measurement, which does not use age as an input, would avoid this problem. Third, the sample was small, no a priori sample size calculation was performed, and the model was validated only internally, with imperfect calibration. Fourth, controls were recruited from a cardiology outpatient clinic rather than from the general population and had a high prevalence of cardiovascular risk factors. Participants receiving antihypertensive treatment were included, and antihypertensive drug classes, doses and other medications (such as statins) were not recorded; because antihypertensive drugs can reduce arterial stiffness beyond their blood pressure-lowering effect [36], differences in treatment between groups may have influenced the results. In addition, fasting status could not be verified in all participants, so glucose values may not uniformly represent fasting measurements. Fifth, nocturnal blood pressure, optic disc morphology and LA area or volume were not assessed, and thrombophilia screening (protein C, protein S, antithrombin III, lupus anticoagulant and anticardiolipin antibodies) was not performed systematically in all participants, although prothrombotic factors may contribute to NAION in selected patients [37,38]. Finally, long-term visual and cardiovascular outcomes were not evaluated.

5. Conclusions

In this single-center case–control sample, estimated aortic PWV and AIx@75 were higher in patients with NAION than in controls after adjustment for age, sex, blood pressure, diabetes and hypertension. Because the device derives PWV partly from age, the size of the adjusted association for PWV should be interpreted with caution. Reference-standard measurements and prospective studies are needed before causal or clinical conclusions can be drawn.

Supplementary Materials

The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/jcm15239272/s1: Figure S1: Individual estimated aortic PWV values plotted against age and device-measured brachial systolic blood pressure, by group; Table S1: Pearson correlation matrix of age and hemodynamic variables; Figure S2: Representative anonymized Mobil-o-Graph device report.

Author Contributions

Conceptualization, Ö.G.; methodology, Ö.G.; formal analysis, M.K.Ş.; investigation, Ö.G., Ö.Y., A.Ç., M.U. and İ.G.; resources, İ.G.; data curation, Ö.G., Ö.Y., A.Ç. and M.U.; writing—original draft preparation, Ö.G.; writing—review and editing, M.K.Ş., Ö.Y., A.Ç., M.U. and İ.G.; supervision, Ö.G.; project administration, Ö.G. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Clinical Research Ethics Committee of Ondokuz Mayıs University (decision no. OMU KAEK 2026/574, date 24 April 2026).

Data Availability Statement

The data presented in this study are available from the corresponding author on reasonable request.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

AIx@75, augmentation index normalized to 75 bpm; ANCOVA, analysis of covariance; AUC, area under the curve; BMI, body mass index; BP, blood pressure; CI, confidence interval; CO, cardiac output; CRP, C-reactive protein; DBP, diastolic blood pressure; DM, diabetes mellitus; EAS, European Atherosclerosis Society; ESC, European Society of Cardiology; ESR, erythrocyte sedimentation rate; EULAR, European Alliance of Associations for Rheumatology; HFmrEF, heart failure with mildly reduced ejection fraction; HFpEF, heart failure with preserved ejection fraction; HFrEF, heart failure with reduced ejection fraction; HT, hypertension; IQR, interquartile range; LA, left atrium; LDL-C, low-density lipoprotein cholesterol; LVEF, left ventricular ejection fraction; MAP, mean arterial pressure; ML, maximum likelihood; NAION, non-arteritic anterior ischemic optic neuropathy; OR, odds ratio; OSAS, obstructive sleep apnea syndrome; PWA, pulse wave analysis; PWV, pulse wave velocity; ROC, receiver operating characteristic; SBP, systolic blood pressure; SD, standard deviation; SE, standard error; STROBE, Strengthening the Reporting of Observational Studies in Epidemiology; SV, stroke volume; TVR, total vascular resistance; VIF, variance inflation factor.

References

  1. Biousse, V.; Newman, N.J. Ischemic optic neuropathies. N. Engl. J. Med. 2015, 372, 2428–2436. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Newman, N.J.; Scherer, R.; Langenberg, P.; Kelman, S.; Feldon, S.; Kaufman, D.; Dickersin, K.; Ischemic Optic Neuropathy Decompression Trial Research Group. The fellow eye in NAION: Report from the Ischemic Optic Neuropathy Decompression Trial follow-up study. Am. J. Ophthalmol. 2002, 134, 317–328. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Atkins, E.J.; Bruce, B.B.; Newman, N.J.; Biousse, V. Treatment of nonarteritic anterior ischemic optic neuropathy. Surv. Ophthalmol. 2010, 55, 47–63. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Hayreh, S.S.; Joos, K.M.; Podhajsky, P.A.; Long, C.R. Systemic diseases associated with nonarteritic anterior ischemic optic neuropathy. Am. J. Ophthalmol. 1994, 118, 766–780. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Salvetat, M.L.; Pellegrini, F.; Spadea, L.; Salati, C.; Zeppieri, M. Non-arteritic anterior ischemic optic neuropathy (NA-AION): A comprehensive overview. Vision 2023, 7, 72. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Martin-Gutierrez, M.P.; Petzold, A.; Saihan, Z. NAION or not NAION? A literature review of pathogenesis and differential diagnosis of anterior ischaemic optic neuropathies. Eye 2024, 38, 418–425, Erratum in Eye 2024, 38, 631. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Hayreh, S.S. Anterior ischaemic optic neuropathy. I. Terminology and pathogenesis. Br. J. Ophthalmol. 1974, 58, 955–963. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Morrow, M.J. Ischemic optic neuropathy. Continuum 2019, 25, 1215–1235. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Bernstein, S.L.; Miller, N.R. Ischemic optic neuropathies and their models: Disease comparisons, model strengths and weaknesses. Jpn. J. Ophthalmol. 2015, 59, 135–147. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Laurent, S.; Cockcroft, J.; Van Bortel, L.; Boutouyrie, P.; Giannattasio, C.; Hayoz, D.; Pannier, B.; Vlachopoulos, C.; Wilkinson, I.; Struijker-Boudier, H. Expert consensus document on arterial stiffness: Methodological issues and clinical applications. Eur. Heart J. 2006, 27, 2588–2605. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Mitchell, G.F.; Hwang, S.J.; Vasan, R.S.; Larson, M.G.; Pencina, M.J.; Hamburg, N.M.; Vita, J.A.; Levy, D.; Benjamin, E.J. Arterial stiffness and cardiovascular events: The Framingham Heart Study. Circulation 2010, 121, 505–511. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Reeve, E.H.; Barnes, J.N.; Moir, M.E.; Walker, A.E. Impact of arterial stiffness on cerebrovascular function: A review of evidence from humans and preclinical models. Am. J. Physiol. Heart Circ. Physiol. 2024, 326, H689–H704. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Mack, C.P. Targeting vascular stiffness. Arterioscler. Thromb. Vasc. Biol. 2024, 44, 2204–2206. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Weiss, W.; Gohlisch, C.; Harsch-Gladisch, C.; Tölle, M.; Zidek, W.; van der Giet, M. Oscillometric estimation of central blood pressure: Validation of the Mobil-O-Graph in comparison with the SphygmoCor device. Blood Press. Monit. 2012, 17, 128–131. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Hametner, B.; Wassertheurer, S.; Kropf, J.; Mayer, C.; Eber, B.; Weber, T. Oscillometric estimation of aortic pulse wave velocity: Comparison with intra-aortic catheter measurements. Blood Press. Monit. 2013, 18, 173–176. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Schwartz, J.E.; Feig, P.U.; Izzo, J.L. Pulse wave velocities derived from cuff ambulatory pulse wave analysis. Hypertension 2019, 74, 111–116. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Vaios, V.; Georgianos, P.I.; Vareta, G.; Divanis, D.; Dounousi, E.; Eleftheriadis, T.; Papagianni, A.; Zebekakis, P.E.; Liakopoulos, V. Age dependence of brachial cuff-based ambulatory PWV in end-stage kidney disease patients undergoing long-term peritoneal dialysis. Perit. Dial. Int. 2022, 42, 65–74. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Yao, F.; Wan, P.; Su, Y.; Liu, W.; Liang, Y.; Xiao, T.; Zhang, J. Impaired systemic vascular endothelial function in patients with non-arteritic anterior ischaemic optic neuropathy. Graefe’s Arch. Clin. Exp. Ophthalmol. 2016, 254, 977–981. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Zhu, W.; Chen, T.; Jin, L.; Wang, H.; Yao, F.; Wang, C.; Wang, Q.; Congdon, N. Carotid artery intimal medial thickness and carotid artery plaques in hypertensive patients with non-arteritic anterior ischaemic optic neuropathy. Graefe’s Arch. Clin. Exp. Ophthalmol. 2017, 255, 2037–2043. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Sanjari, M.S.; Falavarjani, K.G.; Mehrabani, M.; Ghiasian, L.; Zamani, B. Retrobulbar haemodynamics and carotid wall thickness in patients with non-arteritic anterior ischaemic optic neuropathy. Br. J. Ophthalmol. 2009, 93, 638–640. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Koçak, N.; Yeter, V.; Turunç, M.; Bayrambaş, M.; Eraydın, B.; Güngör, İ. Atherogenic indices in non-arteritic ischemic optic neuropathy. Int. J. Ophthalmol. 2021, 14, 1041–1046. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Castilla-Guerra, L.; Gómez-Escobar, A.J.; Gutiérrez-Sánchez, E.; Luque-Linero, P.; Dominguez Álvarez, R.; Gandullo Moro, M.; Rico-Corral, M.Á. Impact of arterial hypertension on ocular vascular ischemia. Rev. Clin. Esp. 2025, 225, 502389. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Lee, T.; Bae, H.W.; Seong, G.J.; Kim, C.Y.; Lee, S.Y. High pulse wave velocity is associated with decreased macular vessel density in normal-tension glaucoma. Invest. Ophthalmol. Vis. Sci. 2021, 62, 12. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. Gouliopoulos, N.; Siasos, G.; Moschos, M.M.; Oikonomou, E.; Rouvas, A.; Bletsa, E.; Stampouloglou, P.; Siasou, G.; Paraskevopoulos, T.; Vlasis, K.; et al. Endothelial dysfunction and impaired arterial wall properties in patients with retinal vein occlusion. Vasc. Med. 2020, 25, 302–308. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. von Elm, E.; Altman, D.G.; Egger, M.; Pocock, S.J.; Gøtzsche, P.C.; Vandenbroucke, J.P.; STROBE Initiative. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: Guidelines for reporting observational studies. Lancet 2007, 370, 1453–1457. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. Ponte, C.; Grayson, P.C.; Robson, J.C.; Suppiah, R.; Gribbons, K.B.; Judge, A.; Craven, A.; Khalid, S.; Hutchings, A.; Watts, R.A.; et al. 2022 American College of Rheumatology/EULAR classification criteria for giant cell arteritis. Ann. Rheum. Dis. 2022, 81, 1647–1653. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. McEvoy, J.W.; McCarthy, C.P.; Bruno, R.M.; Brouwers, S.; Canavan, M.D.; Ceconi, C.; Christodorescu, R.M.; Daskalopoulou, S.S.; Ferro, C.J.; Gerdts, E.; et al. 2024 ESC Guidelines for the management of elevated blood pressure and hypertension. Eur. Heart J. 2024, 45, 3912–4018. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. American Diabetes Association Professional Practice Committee. 2. Diagnosis and classification of diabetes: Standards of Care in Diabetes—2025. Diabetes Care 2025, 48, S27–S49. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Mach, F.; Koskinas, K.C.; Roeters van Lennep, J.E.; Tokgözoğlu, L.; Badimon, L.; Baigent, C.; Benn, M.; Binder, C.J.; Catapano, A.L.; De Backer, G.G.; et al. 2025 Focused Update of the 2019 ESC/EAS Guidelines for the management of dyslipidaemias. Eur. Heart J. 2025, 46, 4359–4378. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Firth, D. Bias reduction of maximum likelihood estimates. Biometrika 1993, 80, 27–38. [Google Scholar] [CrossRef]
  31. Papaioannou, T.G.; Thymis, J.; Benas, D.; Triantafyllidi, H.; Kostelli, G.; Pavlidis, G.; Kousathana, F.; Katogiannis, K.; Vlastos, D.; Lambadiari, V.; et al. Measurement of central augmentation index by three different methods and techniques: Agreement among Arteriograph, Complior, and Mobil-O-Graph devices. J. Clin. Hypertens. 2019, 21, 1386–1392. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Boutouyrie, P.; Chowienczyk, P.; Humphrey, J.D.; Mitchell, G.F. Arterial stiffness and cardiovascular risk in hypertension. Circ. Res. 2021, 128, 864–886. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Hayreh, S.S.; Podhajsky, P.; Zimmerman, M.B. Role of nocturnal arterial hypotension in optic nerve head ischemic disorders. Ophthalmologica 1999, 213, 76–96. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Özdemir, A.; Güngör, İ. 24-hour blood pressure patterns in NAION: Exploring the impact of dipping classifications and comorbidities. Neuro-Ophthalmol. 2025, 49, 382–390. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Taub, C.C.; Stainback, R.F.; Abraham, T.; Forsha, D.; Garcia-Sayan, E.; Hill, J.C.; Hung, J.; Mitchell, C.; Rigolin, V.H.; Sachdev, V.; et al. Guidelines for the standardization of adult echocardiography reporting: Recommendations from the American Society of Echocardiography. J. Am. Soc. Echocardiogr. 2025, 38, 735–774. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Ong, K.T.; Delerme, S.; Pannier, B.; Safar, M.E.; Benetos, A.; Laurent, S.; Boutouyrie, P. Aortic stiffness is reduced beyond blood pressure lowering by short-term and long-term antihypertensive treatment: A meta-analysis of individual data in 294 patients. J. Hypertens. 2011, 29, 1034–1042. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Kuhli-Hattenbach, C.; Scharrer, I.; Lüchtenberg, M.; Hattenbach, L.O. Selective thrombophilia screening of patients with nonarteritic anterior ischemic optic neuropathy. Graefes Arch. Clin. Exp. Ophthalmol. 2009, 247, 485–490. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Nagy, V.; Steiber, Z.; Takacs, L.; Vereb, G.; Berta, A.; Bereczky, Z.; Pfliegler, G. Trombophilic screening for nonarteritic anterior ischemic optic neuropathy. Graefe’s Arch. Clin. Exp. Ophthalmol. 2006, 244, 3–8. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.