Highly Porous Titanium Cups Frequently Presenting with Radiolucent Lines in Cementless Primary Total Hip Arthroplasty: A Retrospective Cohort Study
Abstract
:1. Introduction
2. Materials and Methods
2.1. Study Design
2.2. Surgical Procedure
2.3. Clinical and Radiographic Evaluation
2.4. Statistical Analysis
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Moldovan, F.; Moldovan, L.; Bataga, T. A comprehensive research on the prevalence and evolution trend of orthopedic surgeries in Romania. Healthcare 2023, 11, 1866. [Google Scholar] [CrossRef] [PubMed]
- Sanders, T.L.; Maradit Kremers, H.; Schleck, C.D.; Larson, D.R.; Berry, D.J. Subsequent total joint arthroplasty after primary total knee or hip arthroplasty: A 40-year population-based study. J. Bone Jt. Surg. Am. 2017, 99, 396–401. [Google Scholar] [CrossRef] [PubMed]
- Inacio, M.C.S.; Graves, S.E.; Pratt, N.L.; Roughead, E.E.; Nemes, S. Increase in total joint arthroplasty projected from 2014 to 2046 in Australia: A conservative local model with international implications. Clin. Orthop. Relat. Res. 2017, 475, 2130–2137. [Google Scholar] [CrossRef] [PubMed]
- Malchau, H.; Garellick, G.; Berry, D.; Harris, W.H.; Robertson, O.; Kärrlholm, J.; Lewallen, D.; Bragdon, C.R.; Lidgren, L.; Herberts, P. Arthroplasty implant registries over the past five decades: Development, current, and future impact. J. Orthop. Res. 2018, 36, 2319–2330. [Google Scholar] [CrossRef] [PubMed]
- Matsuoka, H.; Nanmo, H.; Nojiri, S.; Nagao, M.; Nishizaki, Y. Projected numbers of knee and hip arthroplasties up to the year 2030 in Japan. J. Orthop. Sci. 2023, 28, 161–166. [Google Scholar] [CrossRef] [PubMed]
- Macheras, G.A.; Kateros, K.; Koutsostathis, S.D.; Tsakotos, G.; Galanakos, S.; Papadakis, S.A. The Trabecular Metal monoblock acetabular component in patients with high congenital hip dislocation: A prospective study. J. Bone Jt. Surg. Br. 2010, 92B, 624–628. [Google Scholar] [CrossRef]
- Macheras, G.; Kateros, K.; Kostakos, A.; Koutsostathis, S.; Danomaras, D.; Papagelopoulos, P.J. Eight- to ten-year clinical and radiographic outcome of a porous tantalum monoblock acetabular component. J. Arthroplasty 2009, 24, 705–709. [Google Scholar] [CrossRef] [PubMed]
- Moen, T.C.; Ghate, R.; Salaz, N.; Ghodasra, J.; Stulberg, D.S. A monoblock porous tantalum acetabular cup has no osteolysis on CT at 10 years. Clin. Orthop. Relat. Res. 2011, 469, 382–386. [Google Scholar] [CrossRef] [PubMed]
- Wegrzyn, J.; Kaufman, K.R.; Hanssen, A.D.; Lewallen, D.G. Performance of porous tantalum vs. titanium cup in total hip arthroplasty: Randomized trial with minimum 10-year follow-up. J. Arthroplasty 2015, 30, 1008–1013. [Google Scholar] [CrossRef]
- De Martino, I.; De Santis, V.; Sculco, P.K.; D’Apolito, R.; Poultsides, L.A.; Gasparini, G. Long-term clinical and radiographic outcomes of porous tantalum monoblock acetabular component in primary hip arthroplasty: A minimum of 15-year follow-up. J. Arthroplasty 2016, 31, 110–114. [Google Scholar] [CrossRef]
- Perticarini, L.; Zanon, G.; Rossi, S.M.P.; Benazzo, F.M. Clinical and radiographic outcomes of a trabecular titanium™ acetabular component in hip arthroplasty: Results at minimum 5 years follow-up. BMC Musculoskelet. Disord. 2015, 16, 375. [Google Scholar] [CrossRef]
- Assaf, A.; Manara, J.R.; Teoh, K.H.; Evans, A.R. Mid-term clinical results of the cementless R3 cup and Polarstem total hip arthroplasty. Eur. J. Orthop. Surg. Traumatol. 2019, 29, 827–833. [Google Scholar] [CrossRef]
- Tamaki, Y.; Goto, T.; Takasago, T.; Wada, K.; Hamada, D.; Sairyo, K. Clinical and radiological outcomes of total hip arthroplasty using a highly porous titanium cup or a conventional hydroxyapatite-coated titanium cup: A retrospective study in Japanese patients. J. Orthop. Sci. 2022, 27, 163–168. [Google Scholar] [CrossRef]
- Kaneko, T.; Nakamura, S.; Hayakawa, K.; Tokimura, F.; Miyazaki, T. Clinical and radiological outcomes of total hip arthroplasty in octogenarian patients using a three-dimensional porous titanium cup: A retrospective analysis in Japanese patients. Eur. J. Orthop. Surg. Traumatol. 2023, 33, 2361–2367. [Google Scholar] [CrossRef]
- Naziri, Q.; Issa, K.; Pivec, R.; Harwin, S.F.; Delanois, R.E.; Mont, M.A. Excellent results of primary THA using a highly porous titanium cup. Orthopedics 2013, 36, e390–e394. [Google Scholar] [CrossRef] [PubMed]
- Carli, A.V.; Warth, L.C.; de Mesy Bentley, K.L.; Nestor, B.J. Short to midterm follow-up of the Tritanium primary acetabular component: A cause for concern. J. Arthroplasty 2017, 32, 463–469. [Google Scholar] [CrossRef] [PubMed]
- Yoshioka, S.; Nakano, S.; Kinoshita, Y.; Nakamura, M.; Goto, T.; Hamada, D.; Sairyo, K. Comparison of a highly porous titanium cup (Tritanium) and a conventional hydroxyapatite-coated porous titanium cup: A retrospective analysis of clinical and radiological outcomes in hip arthroplasty among Japanese patients. J. Orthop. Sci. 2018, 23, 967–972. [Google Scholar] [CrossRef] [PubMed]
- Delee, J.G.; Charnley, J. Radiological demarcation of cemented sockets in total hip replacement. Clin. Orthop. Relat. Res. 1976, 121, 20–32. [Google Scholar] [CrossRef]
- McPherson, E.J.; Dorr, L.D.; Gruen, T.A.; Saberi, M.T. Hydroxyapatite-coated proximal ingrowth femoral stems: A matched pair control study. Clin. Orthop. Relat. Res. 1995, 315, 223–230. [Google Scholar]
- Vutescu, E.S.; Hsiue, P.; Paprosky, W.; Nandi, S. Comparative survival analysis of porous tantalum and porous titanium acetabular components in total hip arthroplasty. Hip Int. 2017, 27, 505–508. [Google Scholar] [CrossRef]
- Palomäki, A.; Hemmilä, M.; Laaksonen, I.; Matilainen, M.; Eskelinen, A.; Haapakoski, J.; Puhto, A.; Kettunen, J.; Manninen, M.; Mäkelä, K.T. Implant survival of 6080 Tritanium cups in primary total hip arthroplasty: Aata from the Finnish Arthroplasty Register from 2009 to 2017. J. Bone Jt. Surg. 2020, 102, 1177–1185. [Google Scholar] [CrossRef]
- Bingham, J.S.; Hinckley, N.B.; Deckey, D.G.; Hines, J.; Spangehl, M.J. Primary Tritanium acetabular components have increased rates of radiolucency associated with inferior clinical outcomes at short-term follow-up. Hip Int. 2022, 32, 724–729. [Google Scholar] [CrossRef] [PubMed]
- Wang, J.; DiPietro, J.; Bostrom, M.; Nestor, B.; Padgett, D.; Westrich, G. Clinical and radiographic outcomes with a hydroxyapatite and porous coated cup design. Adv. Orthop. Surg. 2014, 2014, 302969. [Google Scholar] [CrossRef]
- Moilanen, T.; Stocks, G.W.; Freeman, M.A.; Scott, G.; Goodier, W.D.; Evans, S.J. Hydroxyapatite coating of an acetabular prosthesis: Effect on stability. J. Bone Jt. Surg. Br. 1996, 78, 200–205. [Google Scholar] [CrossRef]
- Long, W.J.; Nayyar, S.; Chen, K.K.; Novikov, D.; Davidovitch, R.I.; Vigdorchik, J.M. Early aseptic loosening of the Tritanium primary acetabular component with screw fixation. Arthroplast. Today 2018, 4, 169–174. [Google Scholar] [CrossRef]
- Oishi, K.; Yamamoto, Y.; Harada, Y.; Inoue, R.; Sasaki, E.; Ishibashi, Y. Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty. J. Orthop. Surg. Res. 2021, 16, 266. [Google Scholar] [CrossRef]
Highly Porous Titanium Cup | HA-Coated Porous Titanium Cup | p-Value | |
---|---|---|---|
No. of hips | 17 | 34 | |
Age (y) * | 63.8 ± 15.7 | 67.0 ± 14.9 | 0.47 |
Sex (M/F) | 3/14 | 5/29 | 1 |
Height (cm) * | 153.1 ± 10.2 | 152.7 ± 8.3 | 0.88 |
Weight (kg) * | 56.2 ± 11.5 | 54.6 ± 9.7 | 0.61 |
Body mass index (kg/m2) * | 23.9 ± 3.8 | 23.5 ± 4.2 | 0.75 |
Lumbar BMD (t-score) * | –1.6 ± 1.7 | –0.6 ± 1.9 | 0.16 |
Diagnosis (no. of patients) | |||
OA | 10 | 28 | 0.08 |
ONFH | 7 | 5 | |
ISF | 0 | 1 |
Highly Porous Titanium Cup | HA-Coated Porous Titanium Cup | p-Value | |
---|---|---|---|
Preoperative HHS * | 44.5 ± 12.5 | 47.2 ± 10.3 | 0.41 |
Postoperative (2 years) HHS * | 89.3 ± 7.4 | 92.3 ± 6.6 | 0.14 |
DeLee and Charnley Zones | Highly Porous Titanium Cup | HA-Coated Porous Titanium Cup | p-Value |
---|---|---|---|
One zone | 5 (29%) (zone I: 3, zone III: 2) | 0 (0%) | |
Two zones | 2 (11%) (zone I & II: 1, zone I & III: 1) | 0 (0%) | |
Three zones | 6 (35%) | 0 (0%) | |
Total | 13/17 (76%) | 0/34 (0%) | <0.001 * |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Ohta, Y.; Sugama, R.; Minoda, Y.; Mizokawa, S.; Takahashi, S.; Ikebuchi, M.; Nakatsuchi, T.; Nakamura, H. Highly Porous Titanium Cups Frequently Presenting with Radiolucent Lines in Cementless Primary Total Hip Arthroplasty: A Retrospective Cohort Study. J. Clin. Med. 2024, 13, 3297. https://doi.org/10.3390/jcm13113297
Ohta Y, Sugama R, Minoda Y, Mizokawa S, Takahashi S, Ikebuchi M, Nakatsuchi T, Nakamura H. Highly Porous Titanium Cups Frequently Presenting with Radiolucent Lines in Cementless Primary Total Hip Arthroplasty: A Retrospective Cohort Study. Journal of Clinical Medicine. 2024; 13(11):3297. https://doi.org/10.3390/jcm13113297
Chicago/Turabian StyleOhta, Yoichi, Ryo Sugama, Yukihide Minoda, Shigekazu Mizokawa, Shinji Takahashi, Mitsuhiko Ikebuchi, Tamotsu Nakatsuchi, and Hiroaki Nakamura. 2024. "Highly Porous Titanium Cups Frequently Presenting with Radiolucent Lines in Cementless Primary Total Hip Arthroplasty: A Retrospective Cohort Study" Journal of Clinical Medicine 13, no. 11: 3297. https://doi.org/10.3390/jcm13113297
APA StyleOhta, Y., Sugama, R., Minoda, Y., Mizokawa, S., Takahashi, S., Ikebuchi, M., Nakatsuchi, T., & Nakamura, H. (2024). Highly Porous Titanium Cups Frequently Presenting with Radiolucent Lines in Cementless Primary Total Hip Arthroplasty: A Retrospective Cohort Study. Journal of Clinical Medicine, 13(11), 3297. https://doi.org/10.3390/jcm13113297