Skip to Content
Applied SciencesApplied Sciences
  • Article
  • Open Access

21 April 2026

14 Pages

New Possibilities of Testing the Darkening of Automatic Welding Filters as Expressed by Switching Time

and
Department of Personal Protective Equipment, Central Institute for Labour Protection–National Research Institute, Wierzbowa 48, 90-133 Lodz, Poland
*
Author to whom correspondence should be addressed.

Abstract

Welders constitute an occupational group that is particularly exposed to high-risk hazards arising from harmful radiation emitted during welding, including ultraviolet (UV) and infrared (IR) radiation, as well as visible (VIS) radiation, whose high intensity causes glare. Effective protection of the eyes and face is provided by welding shields equipped with automatic welding filters (AWFs), which activate automatically upon arc ignition. Their switching time is the most important protective parameter, as it has a direct impact on the user’s visual health. The objective of the work is to present a novel test stand for determining AWFs switching and holding times, which provides advanced possibilities for evaluating all types of AWFs. Until now, performance and safety levels have been determined based on numerical values: switching time and hold time. For the first time, it is possible to analyze the darkening and clearing phenomena over time with an interpretation of graphical results. Importantly, it is possible to analyze the symmetry of filter properties, using two measurement channels, which is crucial for binocular and curved (panoramic) AWFs. The results obtained for two types of AWFs mounted in goggles with a one-piece and a binocular visor differ from each other. Switching time differences between the left and right measurement channels were about 6–7% for the one-piece visor goggles (G1) and about 3–4% for the binocular goggles (G2). The dispersion of results confirmed the importance of the two measurement channels, which was not previously practiced. The test stand, designed in accordance with the requirements of the new European standards (EN ISO 18526-2:2020, EN ISO 16321-2:2021), can be used for prototyping and for AWF certification purposes.

1. Introduction

Viewing a welding arc with the naked eye or without appropriate personal protective equipment can cause retinal injury due to harmful UV, IR, and high-intensity visible (VIS) radiation, including blue light [1,2]. The use of automatic welding filters (AWFs) in welding eye and face protection devices is considered the most effective solution [3,4,5] in terms of both safety and user comfort. Upon arc ignition, an AWF automatically darkens to a shade number that is appropriate for a given radiation intensity.
In welding operations where eye protection is provided by AWFs, safety is assessed by verifying filter performance levels (determined from luminous transmittance measurements) and by determining two critical parameters: switching time (also known as response time or trigger time) and holding time (the time over which the filter remains darkened after arc extinction). These parameters can be regarded as measures of effectiveness and safety because they directly affect the user’s visual health [6].
AWF darkening involves changes occurring when a filter transitions from the light state to the darkened state, simultaneously with the ignition of a welding arc. The term “simultaneously” is understood here to mean either “at the same time” or “immediately after” the emergence of a hazard in the form of harmful radiation. Naturally, this time must be extremely short for eye and face protection to be effective. The properties of the filter, including its switching time, result from its specialized design. In his research, Palmer focused on the multilayer construction of the filter and on liquid-crystal cells in terms of reliability [5], as well as on improving optical performance and user safety [7]. Also Pościk [8] worked on filter design, and specifically on selecting a photochromic dye to develop an active welding filter with a photochromic layer. Liu and collaborators reviewed methods for estimating switching time and analyzed differences between European and American standards as compared with Australian and New Zealand standards [9]. However, their study does not involve any experimental determination of actual switching times and therefore cannot be directly compared with the results presented in this paper. Queries of the Web of Science, ResearchGate, and Google Scholar databases indicate a lack of literature addressing experimental investigations of the switching time of automatic welding filters. This is particularly notable given the recent introduction of new panoramic AWFs, as well as AWFs integrated into goggle housings with single-visor and binocular designs. In response to these developments, new normative requirements have been established, reflecting an updated classification of AWFs [10,11]. Consequently, testing laboratories are required to adapt their research equipment accordingly. This paper presents, for the first time, a test stand and its functionalities designed to accommodate the new filter designs and the requirements of the latest ISO standards. There is a research gap in this area, as no such solution has been developed in other laboratories to date. Researchers at the Central Institute for Labour Protection–National Research Institute (CIOP–PIB) are the only authors who have explored this topic over the past twenty years. During this time, two test stands for evaluating the switching time of AWFs have been developed and implemented at the Department of Personal Protective Equipment. Recent work at the CIOP–PIB [12,13], conducted since 2023, has concerned the study of the protective properties of AWF expressed by switching time.
The switching time of commercially available AWFs is on the order of 1/25,000 s. As regards holding time, the transition from the darkened state back to the light state should not occur before the harmful radiation from the welding arc is extinguished. The measured values, in conjunction with the requirements of the measurement procedure pursuant to the new international standards [10,11], necessitated the construction of a specialized test stand. Studies of the protective properties of AWFs, expressed in terms of switching (and holding) times, were carried out as part of a research project at the Eye and Face Protection Laboratory (CIOP-PIB) [12,13,14]. During the implementation of the research project, a problem was identified—the devices currently used to measure switching and holding times are limited in that they provide results in the form of a single numerical value representing either of the two parameters. In addition, they are constrained by the dimensions of the measurement system and by sample-mounting assemblies that enable the testing of flat AWFs only. In 2024, a novel test stand was developed at the Eye and Face Protection Laboratory of the Central Institute for Labour Protection–National Research Institute (CIOP-PIB) to determine the switching and holding times of all types of AWFs (with no technical limitations regarding sample mounting or measurement) with an additional capability of tracking the course of filter darkening and clearing over time. Time-resolved analysis of these phenomena offers a comprehensive picture of filter performance. It has become evident that only now—by means of the new, advanced test stand—is it possible to conduct a more precise filter evaluation and obtain additional data for comparative purposes. The developed unique and fully automated test stand is the only one of its kind in Europe. It offers a competitive advantage in several aspects that are significant for both users of welding protective equipment incorporating AWFs and for its manufacturers.
The aim of this study is to present a new test stand for evaluating AWFs in accordance with the requirements of the standard EN ISO 16321-2 [11] and the procedure specified in EN ISO 18526-2 [10]. The beneficiaries of this work include designers, manufacturers, and users of AWFs. Manufacturers gain new capabilities for evaluating AWF filter prototypes by obtaining detailed numerical and graphical data on actual filter performance from two independent measurement channels with a higher level of accuracy. This creates opportunities for further refinement and modification, as well as for the design of new welding protective equipment equipped with AWFs. The application of the new test stand for research and certification purposes will contribute to the introduction of safer, higher-quality AWFs to the market, thereby improving user safety. The results obtained using the new test stand demonstrate its versatility and broad applicability to all types of single-visor and binocular designs with varying geometries. A limitation of the presented test stand and research procedure is the duration of the full testing cycle, which currently amounts to 4 h per sample, including conditioning at three temperatures in accordance with the requirements of the standard.

2. Materials and Methods

Switching and holding times are calculated from luminous transmittance measurements and the corresponding dark states determined pursuant to the formula specified in the standard EN 4007:2018 [15], which is referenced by the standard EN ISO 18526-2:2020 [10]. The test stand enables the measurement of luminous transmittance in a closed and repeatable system (relative results). Repeatable and stable conditions are also ensured with respect to conditioning and test temperatures. The test stand contains a heating and cooling module with an independent temperature control to prevent filter fogging, which is often reported by other laboratories. Sample conditioning in a climatic chamber for a sufficiently long time eliminates the adverse effects of fogging on measurement results. The test stand has been future-proofed; therefore, it enables the measurement of AWF light transmittance parameters in the dark state up to shade level 14 and in the light state in the range of shade level 1–4. The applied heating and cooling system ensures a temperature control accuracy of 0.5 °C.
The test stand incorporates solutions designed to account for differences in filter shape and size, and therefore it does not have limitations concerning the measurement of either panoramic or flat filters, whether with one-piece or two-piece visors. Measurement results are not affected by filter geometry. Different numbers and arrangements of radiation sensors in filters do not constitute a limitation, either. The triggering module is equipped with a light source mounted on a flexible arm that can be precisely directed at one of the filter’s sensors. Furthermore, samples in the form of complete welding shields equipped with AWFs are mounted on a headform, which does not limit the range of test specimens and enables testing under conditions that replicate their actual use.
The test stand was designed in accordance with the requirements of the standards EN ISO 18526-2:2020 and EN ISO 16321-2:2021 [10,11] and consists of lighting, triggering, detection (measurement), heating/cooling, and control modules. The key electronic and optical components are part of the detection and lighting modules, namely a source of triggering light, the lighting module system with lasers for sample positioning, and the detection module with photosensors. The other, mostly mechanical, elements include the casing, the trigger light and auxiliary light arm, the head-shaped sample mount, the two measurement channels, as well as radiators and fans.
A measurement system with two measurement channels has been implemented in this device for the first time. The rationale for this solution is the ability to assess the uniformity and symmetry of filter properties. This is particularly important when testing protective equipment with dual-filter (binocular) systems. Notably, this aspect was not addressed in the most recent revision of the standards.
The new ISO standards have introduced significant changes, including stricter requirements for the measurement procedure. The standard requirements regarding the accuracy of the sample’s angular alignment relative to the measuring light source (±1°) were incorporated in the test stand design already at the drafting stage. Figure 1 shows the filter-positioning system—an integral part of the lighting module during assembly. Figure 2 visualizes the two-stage filter-positioning process.
Figure 1. Filter positioning system: (a) the back wall of the lighting system after assembly; (b) control board for the lasers displaying the central spot and vertical lines during sample positioning; (c) finishing touches on the integration of the lighting and positioning modules; (d) base of the head-shaped mount for samples with a trigger light detection system (two sensors).
Figure 2. Filter positioning: (a) system for preliminary filter positioning (centered with respect to the head mount and the measurement system); (b) concept behind the final filter positioning system (verification of the filter’s perpendicular alignment with respect to the measurement light); (c) view of the filter positioning system and the system verifying angular positioning accuracy.
Figure 2 visualizes the two-stage filter-positioning process. Initial positioning of the filter is carried out using auxiliary red laser guide beams projected by the lighting module, arranged symmetrically on the sides of the vertical central axis of the head mount. The filter should be placed between the vertical laser lines, and the distance between them should correspond to the width of the filter or that of some other symmetrical structural elements. Figure 2a shows a view of the vertical lines correctly aligned on a sample during the initial positioning stage. The final positioning of the filter requires checking the angular accuracy of the sample position. In this step, the operator needs to adjust the red laser dot projected by the system and reflected off the sample. This is implemented by means of an innovative method based on basic mathematical and physical principles. We determined the tolerance of the sample angle with respect to the measurement light beam in terms of a circle (a metal O-ring) with a calculated diameter. The requirement concerning sample positioning accuracy is met when the red laser dot falls within the metal O-ring area. Figure 2b,c show a view of the filter positioning system and the system verifying angular positioning accuracy.
A view of the test stand for measuring AWF switching and holding times is shown in Figure 3. Figure 3a presents a schematic of the stand, while Figure 3b shows its visual rendering (with the chamber closed). Figure 3c shows an actual view. Figure 3d presents sample during positioning to align it according to standard requirements and the arm with the trigger light source directed at the filter sensor.
Figure 3. Test stand for AWF switching time determination: (a) schematic; (b) 3D model, (c) actual view and (d) during sample testing.
The procedure for testing switching time is simple and automated; all the operator needs to do is mount a sample on the head-shaped holder, check the sample alignment using the laser positioning system, and set the trigger light arm. After the chamber is closed, the subsequent test stages are carried out automatically in accordance with the selected operating mode—automatic or manual. In the automatic mode, three measurements are performed at three conditioning temperatures (according to the standard EN ISO 18526-2:2020 requirements). The manual mode enables a single measurement to be done using user-defined settings for conditioning and measurement temperatures, as well as for the sample conditioning time. The measurement procedure begins with auto-calibration to determine the initial parameters (measuring the ambient temperature, establishing a baseline for transmittance measurements, and verifying the proper operation of the illumination system and sensors), thereby obtaining reference measurements and results. The system then measures all parameters, starting with the light transmittance coefficient for the light and dark states. Based on these, it determines the threshold values for switching and holding times. For the identification of the switching moment, a sampling process is performed, configured to achieve the required accuracy (2 MSa/s sampling) until transmittance changes to the value specified in the standard as the dark state. The result is recorded when transmittance reaches three times the transmittance value for the dark state. The measurement is conducted continuously after the result is recorded until the full characteristics of the dimming phenomenon are obtained.
The results are presented in a table and as a chart (values from 13 replicates). The measurement system provides averaged results for the estimated static parameters as a weighted average of 300 samples for both the light and darkened states. For each filter, a single test yields two series of results for switching and holding times, obtained from the two channels of the measurement/detection module. The left and right channels correspond to the results for the left and right eye, which extends the stand’s applicability to testing and comparing AWFs implemented in binocular spectacles and goggles.
From the perspective of potential users (first, designers and manufacturers, and then end users), the most useful feature is the ability to identify changes in filters from the moment the welding arc is ignited until it is extinguished. The response dynamics of a filter during darkening and the maintenance of the darkened state until the return to the light state are characteristic features of each filter and distinguish filter models from different manufacturers, and even products from the same manufacturer. The course of the darkening phenomenon—and specifically its initial phase, the latency prior to triggering—has a direct impact on filter performance as expressed by switching time.
One of the special features of the stand—and one of its competitive advantages—is the measurement system, which consists of two independent channels. In addition, the device displays the actual degree of filter darkening, determined on the basis of the measured luminous transmittance. The results provide complete information about the protective properties for the left eye and right eye areas. A view of the results screen is shown in Figure 4.
Figure 4. Results screen—table with results obtained for the left and right measurement channels at 23 °C.
From the manufacturer’s perspective, the obtained results provide information on the symmetry of protective parameters (luminous transmittance and the corresponding protection levels, switching time, and holding time). This is of particular importance given the vast variety of filter designs and geometries. From the user’s perspective, an AWF with a certificate of quality that verifies its protective properties based on tests conducted on the new stand means improved work safety.
The study covered two types of AWFs integrated into the housings of goggles manufactured by a single manufacturer: goggles with a binocular visor (where the AWF consists of two separate filters) and goggles with a one-piece visor. The tests were carried out on a validated test stand. Switching and holding times of the filters were determined, as well as their actual levels of darkening. The parameters from the two measurement channels were compared using percentage differences and basic statistics. Photographs of the tested goggles are shown in Figure 5.
Figure 5. Photographs of the tested items: (a) welding goggles with a one-piece AWF (G1); and (b) welding goggles with a two-piece (binocular) AWF (G2).
Example measurement results obtained at three temperatures, 23 ± 2 °C, −5 ± 2 °C, and 55 ± 2 °C—in accordance with the requirements of the latest ISO standards—are shown in Figure 6. It should be noted that the software provides partial results, i.e., shade numbers (calculated from luminous transmittance measurements—which are available in the advanced program settings), as well as the main results in the form of switching time and holding time values. The presented results, broken down into left and right channels, enable the assessment of the symmetry of the filter’s properties.
Figure 6. Results screens for the temperatures required by the standard: (a) −5 ± 2 °C; (b) 23 ± 2 °C; (c) 55 ± 2 °C.
Moreover, the device plots graphs of the filter darkening and clearing processes. Example plots of darkening over time for the left and right channels, illustrating differences in the phenomena, are shown in Figure 7.
Figure 7. Example darkening time course for the left measurement channel.

3. Results

The aim of the study is to present the possibilities of the novel test stand for testing switching times in all types of AWFs, including those with one-piece and two-piece (binocular) visors. Test results provide numerical switching time values complete with measurements of actual shade numbers, as well as a graphical interpretation of the results—a darkening curve over time. The switching time results for AWFs measured at 23 ± 2 °C in 13 replicates for welding goggles G1 with a one-piece visor and for G2 goggles with a two-piece (binocular) visor, for shade numbers declared by the manufacturer (9, 11, and 13), are presented in Table 1. The results for the two measurement channels, left and right, are marked L and R, respectively. A comparison of the measured shade numbers with those declared by the manufacturer is provided in Table 2.
Table 1. Switching time results for goggles G1 and G2 for the shade numbers declared by the manufacturer: 9, 11, and 13.
Table 2. Comparison of measured shade numbers with those declared by the AWF manufacturer in the range 9, 11, and 13.
Charts showing the dispersion of switching time results expressed as the percentage difference between the MIN and MAX values split into the left and right channels for goggles G1 and G2 are given in Figure 8.
Figure 8. Dispersion of switching time results expressed as the percentage difference between the MIN and MAX values for goggles G1 and G2, split into the left and right measurement channels.
A comparison of the standard deviation values for switching time results for the left and right channels is given in Figure 9.
Figure 9. Comparison of switching time standard deviation values for goggles G1 and G2, split into the left and right measurement channels.
The test stand also measures luminous transmittance to calculate the actual shade numbers, which can then be compared with those declared by the AWF manufacturers. One such comparison is given in Table 2, with a graphical presentation of results shown in Figure 10.
Figure 10. Comparison of shade number dispersions expressed as differences between the MIN and MAX values, split between the left and right measurement channels.
Figure 11 presents standard deviations as a measure of the dispersion of results from 13 replicates.
Figure 11. Comparison of standard deviation values for shade numbers, split into the left and right measurement channels for goggles G1 and G2.
Figure 12 presents differences in darkening behavior recorded during the measurement of switching time for welding goggles G1 and G2. The legend provides information about switching time values estimated according to EN ISO 18526-2, light and dark states which are presented in a graphic interpretation as different color lines. The presented results are for shade number 9 as declared by the manufacturer.
Figure 12. Darkening behavior over time for the left channel: (a) goggles G1, (b) goggles G2.
In addition, maximum differences in switching time between the left and right measurement channels were compared (in µs) and are presented in Figure 13.
Figure 13. Switching time differences in µs between the left and right measurement channels.

4. Discussion

The results obtained for the tested goggles G1 and G2 indicate that switching time is a parameter exhibiting a certain degree of variability characteristic of a given filter. Evaluation of the repeatability and reproducibility of measurements was based on the calculated standard deviation values. A comparison of the dispersion of results and the symmetry of filter properties was carried out based on percentage differences between the MIN and MAX values.
A comparison of the standard deviation results obtained from 13 replicates indicates considerable differences in SD values between goggles G1 and G2. Goggles G1 exhibited substantially higher results across all declared shade numbers, with SD values ranging from approx. 4 to 5.5 (reaching a maximum of 5.42 for shade number 13 and 5.41 for shade number 9). In contrast, standard deviations for goggles G2 were much lower, ranging from approx. 0.4 to 3.3 (with a maximum of 3.25 for shade number 9).
Based on a comparison of calculated percentage differences between the MIN and MAX switching time values for the analyzed shade numbers, it can be inferred that the differences for goggles G1 were consistent across all analyzed shade numbers and amounted to approximately 3–5%. In contrast, the results obtained for goggles G2 indicate variability among the analyzed shade numbers, with the highest values observed for shade number 9, reaching 4%.
A comparison of standard deviations for the shade numbers determined based on 13 replicates shows that the results for goggles G1 were very uniform and were within a narrow range of 0.15–0.65 (with a maximum value of 0.61 for the declared shade number 9). Goggles G2 exhibited higher SD values, reaching a maximum of 3.42 only for shade number 11 (see Figure 11).
The dispersion of the measured and declared shade numbers, expressed as percentage differences between the MIN and MAX values, indicates that the differences between the measured and declared shade numbers were considerably greater (approx. four times) for goggles G1, amounting to 15–18%. For goggles G2, percentage differences reached 1.3–4%, as illustrated in Figure 10.
The results for the left and right measurement channels differ from each other, as can be seen from Figure 12. The initial phase of filter darkening is characterized by a period of latency, followed by a sudden drop in luminous transmittance, at the end of which switching time is recorded. Interpretation is based on comparing the individual stages of the darkening process. The switching time values obtained from 13 replicates show differences of approx. 30 µs, or about 6–7%, for goggles G1, and by 3–6 µs, or about 3–4%, for goggles G2. For the latter goggles, these differences are negligible, because of the low values of switching times recorded, but in other cases, considerable filter non-uniformity may be found. The standard specifies criteria for acceptable switching times; however, until now, results from two independent measurement channels have not been available. Therefore, to ensure a conservative assessment, the worst-case scenario principle should be applied, and switching times should be taken from the channel that yields the longer values.
In summary, a comparison of the basic statistical parameters from 13 replicates shows that switching time tests exhibit good repeatability and reproducibility (recorded SD values are approx. 4 for goggles G1 and approx. 1 for G2). Thus, the novel test stand was demonstrated to provide stable results with acceptable dispersion due to the electronic nature of AWFs. They are characterized by a certain inherent instability of darkening, which is also confirmed by plots of their darkening behavior over time. While this instability does not pose a hazard to users, it may be the subject of optimization in next-generation designs.
Analysis of the results obtained from the two measurement channels for the studied goggles revealed differences of up to 30 µs (for switching times on the order of 360–400 µs), which do not violate the standard requirements. In the presented case, the one-piece filter proved to be inferior (e.g., exhibited longer switching times) and less stable than the two-piece (binocular) filter.
The plots generated by the test stand software depict each stage of the darkening and clearing process over time. Thus, filter behavior and the dynamics of change can be evaluated. The results show that each filter may exhibit different dynamics, which enables more detailed differentiation of filter properties for comparative purposes, for example, during AWF design and improvement phases.
The primary competitive advantage of the test stand is the ability to obtain results from two measurement channels, which makes it possible to assess the stability and symmetry of filter protective properties. This is particularly important for dual-filter and curved (panoramic) AWFs. In addition, examination of the darkening process on plots enables manufacturers to introduce modifications aimed at increasing the dynamics of darkening and reducing latency. The intended audience of this paper includes manufacturers of welding protective equipment incorporating AWFs. We also hope that other research laboratories, when designing test stands for evaluating switching times, will draw on our experience and adopt dual-channel measurements to assess the symmetry of AWF protective properties.
A limitation of the presented test stand and research procedure is the extended measurement cycle, as the automation of the measurement process and the required conditioning of samples at each specified temperature increase the test time for a single sample up to 4 h.

5. Conclusions

The presented universal and automated test stand for determining switching and holding times, designed in accordance with the requirements of the latest ISO standards, addresses the needs of technological advancement by enabling comprehensive testing of all designs and parameters of welding shields equipped with AWFs. The stand was designed for testing AWFs of all sizes and shapes to eliminate the influence of filter geometry on the results due to the use of a system incorporating two measurement channels dedicated to the left eye and right eye regions. This feature offers an additional capability, i.e., the verification of the binocular symmetry of the most important protective properties, namely luminous transmittance and switching time. The application of this innovative, advanced measurement system enables the acquisition of comprehensive data on the darkening and clearing behavior of AWFs.
The new test stand enables precise analysis of the darkening performance of AWFs based on the time course of the darkening and clearing phenomena. This may serve as a basis for the assessment and comparison of AWF quality as reflected in the dynamics of darkening and subsequent clearing. Such comparisons are important for AWF manufacturers when evaluating prototypes, in the process of product improvement, and later when conducting tests for certification purposes as part of bringing the product to market.

Author Contributions

Conceptualization, J.S.; methodology, J.S.; software, M.J.; validation, J.S.; formal analysis, J.S.; investigation, J.S.; resources, J.S.; data curation, J.S. and M.J.; writing—original draft preparation, J.S.; writing—review and editing, J.S. and M.J.; visualization, J.S. and M.J.; supervision, J.S.; project administration, J.S.; funding acquisition, J.S. All authors have read and agreed to the published version of the manuscript.

Funding

This task was completed based on the results of research carried out within the scope of the 6th stage of the National Programme “Governmental Programme for Improvement of Safety and Working Conditions”, funded by state services of the Ministry of Family, Labour and Social Policy. Task No. 1.ZS.05, entitled “Development of a method for testing the switching time of automatic welding filters.” The Central Institute for Labour Protection–National Research Institute is the Programme’s main co-ordinator.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Acknowledgments

The test stand for determining switching and holding times was built by nProLab (Warsaw, Poland). Since May 2024, the stand has been part of the research and measurement equipment of the Eye and Face Protection Laboratory, Central Institute for Labour Protection–National Research Institute (CIOP-PIB).

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
CIOP-PIBCentral Institute for Labour Protection–National Research Institute
PPEPersonal Protective Equipment
AWFAutomatic Welding Filter
UVUltra violet radiation
IRInfrared radiation
SDStandard deviation
SWSwitching time
HldHolding

References

  1. Nakashima, H.; Takahashi, J.; Fujii, N.; Okuno, T. Hazards associated with blue light emitted during gas metal arc welding of mild steel using various shielding gases and currents. Ind. Health 2023, 62, 79–89. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Fiebai, B.; Awoyesuku, E.A. Ocular injuries among industrial welders in Port Harcourt, Nigeria. Clin. Ophthalmol. 2011, 5, 1261–1263. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Saxena, V. Occupational Hazards and Safety Challenges in Welding Activity. Indian Weld. J. 2023, 56, 66–70. [Google Scholar] [CrossRef] [Scilit]
  4. Lei, T. How to Test the Quality of Auto Darkening Welding Helmets. 2015. Available online: https://www.linkedin.com/pulse/how-test-quality-auto-darkening-welding-helmets-taylors-lei (accessed on 3 March 2026).
  5. Palmer, S. Fast, automatically darkening welding filter offering an improved level of safety. Appl. Opt. 1996, 35, 1088–1094. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Shang, J.; Chen, S.; Cao, Y. Derivation of maximum permissive switching time for automatic welding filter based on retinal thermal and blue light exposure limits. J. Occup. Environ. Hyg. 2022, 19, 558–567. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Palmer, S. Liquid-crystal cell with a wide viewing angle and a high cell contrast. Appl. Opt. 1997, 36, 2094–2100. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Pościk, A.; Wandelt, B. Application of a photochromic dye in an automatic welding filter. Int. J. Occup. Saf. Ergon. 2009, 15, 243–254. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Liu, H.; Jin, S.; Xiao, H.; Hong, Y.; Shen, L. Study on the response characteristic of automatic welding filter. In International Federation for Information Processing (IFIP), Volume 207, Knowledge Enterprise: Intelligent Strategies in Product Design, Manufacturing and Management; Wang, K., Kovacs, G., Wozny, M., Fang, M., Eds.; Springer: Boston, MA, USA, 2006; pp. 1016–1021. [Google Scholar]
  10. EN ISO 18526-2:2020; Eye and Face Protection—Test Methods—Part 2: Physical Optical Properties. International Organization for Standardization: Geneva, Switzerland, 2020.
  11. EN ISO 16321-2:2021; Eye and Face Protection for Occupational Use—Part 2: Additional Requirements for Protectors Used During Welding and Related Techniques. International Organization for Standardization: Geneva, Switzerland, 2021.
  12. Szkudlarek, J.; Drobina, I. A new test stand for the switching time of automatic welding filters evaluation-new possibilities for assessing their protective parameters. In Technologie, Procesy i Systemy Produkcyjne; Rysiński, J., Więcek, D., Eds.; Wydawnictwo Naukowe Uniwersytetu Bielsko-Bialskiego: Bielsko-Biała, Poland, 2023; pp. 145–154. [Google Scholar] [CrossRef] [Scilit]
  13. Szkudlarek, J.; Drobina, I. The switching time determination in aspect of new automatic welding filter (AWF) constructions appearing in the market. In Technologie, Procesy i Systemy Produkcyjne; Rysiński, J., Więcek, D., Eds.; Wydawnictwo Naukowe Uniwersytetu Bielsko-Bialskiego: Bielsko-Biała, Poland, 2023; pp. 91–98. [Google Scholar] [CrossRef] [Scilit]
  14. Szkudlarek, J. Analiza wymagań dotyczących parametrów i badań automatycznych filtrów spawalniczych po wprowadzeniu nowych norm europejskich [Analysis of requirements concerning the parameters and tests of automatic welding filters following the introduction of new European Standards]. Occup. Saf.-Sci. Pract. 2024, 628, 16–21. [Google Scholar] [CrossRef] [Scilit]
  15. EN ISO 4007:2018; Personal Protective Equipment—Eye and Face Protection—Vocabulary. International Organization for Standardization: Geneva, Switzerland, 2018.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.