Skip to Content
Applied SciencesApplied Sciences
  • Article
  • Open Access

27 November 2026

29 Pages

Surrogate-Based Numerical Optimization of Buried PVC Pipes Beneath Strip Footings on Sand Slopes

,
and
1
Construction Technology Program, Ercis Vocational School, Van Yuzuncu Yil University, Erciş 65400, Türkiye
2
Department of Civil Engineering, Istanbul Nisantaşı University, Istanbul 34485, Türkiye
3
Department of Civil Engineering, Dicle University, Diyarbakir 21280, Türkiye
*
Author to whom correspondence should be addressed.
This article belongs to the Section Civil Engineering

Abstract

Pipes along slopes often run beneath shallow foundations. This numerical study examines how the burial depth and flexural stiffness of a buried PVC pipe govern its response beneath a strip footing on a sand slope. A PLAXIS 2D model validated against the footing response in nine reduced-scale model tests was used for 390 analyses covering slope angles of 20–35°, footing setbacks b/B = 0–1, burial depths H/D = 1–4 and pipe stiffness ratios EI/EI0 = 0.25–4. Pipe ovalization decreased six- to tenfold with depth and stiffness and increased with slope angle, while service wall stresses remained well below the design stress of PVC. Pipes buried shallower than about two footing widths reduced the bearing capacity, although the model underestimated this reduction relative to the tests. Gaussian process surrogates predicted the pipe response accurately (R2 ≥ 0.999) but the bearing capacity ratio (BCR) only moderately (R2 = 0.73, and 0.38 for unseen slope–setback combinations); a safety margin was therefore applied to the BCR constraint, and three of the resulting optimal designs satisfied it in independent finite element analyses. With only two design variables and a simplified relative cost index, GA, PSO and DE outperformed random sampling only for the constrained single-objective problem.

1. Introduction

Buried pipes for water supply, drainage and energy transmission are routinely laid along hillsides, embankments and cut slopes, where they often share the ground with shallow foundations of roads, retaining structures and light buildings. In such settings three components interact: the slope reduces the confinement and bearing capacity of the footing, the footing load is transmitted to the pipe, and the pipe in turn alters the stress field and the failure mechanism beneath the footing. Flexible pipes are particularly sensitive to this interaction because their load-carrying capacity depends on the lateral support of the surrounding soil [1,2,3]. Designing such a system therefore involves competing requirements: increasing burial depth and pipe stiffness can reduce pipe deformation but may increase excavation and material demands, while the influence of the pipe on footing bearing capacity must be evaluated separately.
The deformation of buried flexible pipes is governed by the interaction between pipe ring stiffness and the support provided by the surrounding soil. Classical approaches, including the Iowa and modified Iowa formulations, relate pipe deflection to applied loading, flexural stiffness and lateral soil resistance [2,3,4]. The latter is commonly represented by the modulus of soil reaction (E′), an empirical parameter influenced by soil properties and installation conditions [5]. In particular, the compaction of the soil placed beside the pipe (the side-fill) can have a significant effect on the behavior of flexible pipes, particularly at shallow burial [6].
The bearing capacity of footings on or near slopes has been studied since Meyerhof [7], who showed that capacity decreases as the slope steepens and as the footing approaches the crest. Laboratory model tests and finite element analyses have since quantified the roles of slope angle, setback distance, footing width and soil density; for strip footings on sand slopes, Keskin and Laman [8] found that the capacity approaches that of level ground once the setback exceeds about five footing widths. These studies, however, consider homogeneous slopes and do not include buried structures. Slope stability itself has also been analyzed with three-dimensional limit analysis [9] and with reliability analysis based on the random finite element method [10], in both cases for slopes under water drawdown. In contrast to these studies, which concern the stability of the slope alone, the present study considers a dry sand slope in plane strain and addresses the interaction between the footing, the pipe and the slope.
The influence of underground openings on footing behavior was first examined for voids, whose size and position were shown to govern the bearing capacity of strip footings above them [11]. For buried pipes on level ground, Bildik and Laman [12] reported from model tests that the bearing capacity increases as the pipe is buried deeper and placed farther from the footing. Studies combining all three components are recent and few. Khan and Shukla [13] tested footings above conduits buried in sand slopes and identified burial depth as the dominant parameter, recommending a crown depth of at least three footing widths. Zhu et al. [14] used the material point method to show that setback distance and slope angle can reduce the ultimate capacity by up to about 75% and that a shallow pipe accelerates the development of the failure surface. The response of the buried pipe itself has also been examined for this system. Using PLAXIS 2D (version 2024.2), Khan and Shukla [15] computed the deflection, sectional normal stress and bending moment of PVC-U conduits buried within a sand slope beneath a loaded surface footing for different crest distances, burial depths and slope angles, and found deflections considerably larger than under level ground; Khan et al. [16] measured the stress distribution around such a conduit and its deflection in model tests with different crest distances. Pipe–soil interaction along slopes has also been studied for ground movements in unstable slopes [17]. In these studies, however, the wall stiffness of the pipe was not varied independently, the footing served to apply the load and its bearing capacity was not evaluated together with the pipe response, and the results were not used to select a design.
The interpretation of experimental and numerical investigations of buried pipes also requires consideration of scale effects and modeling assumptions. Although reduced-scale physical tests conducted under normal gravity (1g) can reproduce selected geometric relationships and provide information on footing response and failure mechanisms, geometric similarity does not ensure similarity of the stress state between the model and a full-scale installation. This limitation is particularly relevant for granular soils because stiffness and dilatancy depend on confining stress, and scale effects have been observed in comparisons of 1g and centrifuge footing tests [18]. Similarly, two-dimensional plane-strain analyses assume longitudinal continuity of the footing–soil–pipe system. Such models can represent stress redistribution within the analyzed cross-section, but cannot explicitly capture finite-length effects at the footing and pipe ends or the complete three-dimensional development of soil arching. Experimental and numerical investigations of buried flexible pipes have demonstrated the importance of arching and stress redistribution under surface loading [19]. These limitations should therefore be considered when interpreting numerical predictions and transferring model-scale findings to field conditions.
Exploring such a multi-parameter design space with finite element analyses alone is costly, since each analysis of a footing loaded to failure takes minutes to hours. Surrogate models trained on a limited number of numerical analyses are therefore increasingly used to replace the expensive model in design and optimization [20]. Gaussian process (GP) regression is attractive for small engineering datasets because it is non-parametric, interpolates smoothly and provides an estimate of its own uncertainty [21], whereas artificial neural networks (ANNs) are more flexible but typically require larger training sets. How accurately these models reproduce the comparatively small effect of a buried pipe on footing capacity, against the numerical scatter inherent in collapse analyses, has not been examined.
Data-driven approaches have been increasingly applied to related geotechnical problems involving shallow foundations, slopes and buried pipelines. Moayedi and Hayati [22] investigated several soft-computing techniques using finite element results for strip footings located near sandy slopes, demonstrating the applicability of machine-learning models to nonlinear footing–soil responses. However, their investigation did not consider the presence of a buried pipe. More recently, Kounlavong et al. [23] combined finite element limit analysis with hybrid XGBoost models optimized using genetic algorithms (GA), particle swarm optimization (PSO), the slime mold algorithm (SMA) and ant colony optimization (ACO) to predict the penetration resistance of buried pipelines in cohesive soils. In that study, the optimization algorithms were primarily employed to improve surrogate-model predictions rather than to determine the physical design variables of a flexible pipe. These studies establish the relevance of data-driven and optimization-assisted approaches to geotechnical problems, but do not directly address the simultaneous evaluation of pipe ovalization, footing bearing capacity and design optimization through independently varied pipe stiffness and burial depth in sloping ground.
Once a surrogate is available, metaheuristic algorithms are commonly used to search it for optimal designs, and their use in geotechnical engineering has grown rapidly [24], for example in the multi-objective design of retaining walls for cost and CO2 emissions [25] or for cost and safety, where NSGA-II and SPEA2 were compared by hypervolume [26]. For conflicting objectives, the elitist non-dominated sorting genetic algorithm NSGA-II [27] is by far the most widely used, alongside its many-objective extension NSGA-III [28], SPEA2 [29], the decomposition-based MOEA/D [30] and multi-objective particle swarm optimization [31]. At the same time, the optimization community has questioned the steady stream of new metaphor-based algorithms and the practice of reporting them without adequate baselines [32,33], and no algorithm can be expected to outperform others on all problems [34]. A typical recent workflow couples a validated finite element model, a machine-learning surrogate and NSGA-II; Alnmr et al. [35], for example, optimized geosynthetic-reinforced pile-supported embankments in this way using 4282 PLAXIS 3D analyses. Such geotechnical applications, however, rarely compare the metaheuristic against simple alternatives such as random sampling or exhaustive search of the surrogate, so it often remains unclear whether a metaheuristic was needed at all.
This study addresses these gaps. Its principal contribution is geotechnical: it quantifies how the burial depth and, in particular, the flexural stiffness of a flexible pipe govern both the response of the pipe (ovalization and bending moment) and the bearing capacity of a strip footing near the crest of a sand slope, whereas previous studies of this three-component system did not treat the pipe stiffness as an independent variable and separately addressed the footing capacity [13,14] and the response of the pipe [15,16]. The surrogate models and optimization algorithms used here are established methods and are not proposed as new; they are used as tools, and the secondary, methodological contribution is a critical assessment of how reliably they perform for this type of problem. Three research questions are addressed: (i) How do burial depth and pipe stiffness govern pipe ovalization, bending moment and footing capacity for different slope angles and footing setbacks? (ii) How accurately can surrogates trained on a few hundred finite element analyses reproduce these responses, in particular the bearing capacity ratio, for which the effect of the pipe is of the same order as the numerical scatter of collapse loads? (iii) For a design problem with only two variables, do metaheuristic algorithms offer a measurable advantage over random sampling under matched evaluation budgets when their performance is assessed against reference optima and Pareto fronts obtained from exhaustive surrogate-grid evaluations?
The geotechnical investigation is further guided by two testable hypotheses. First, for a given slope angle and footing setback, increasing the burial depth and the flexural stiffness of the pipe is expected to reduce its vertical ovalization under the service load. Second, the pipe stiffness is expected to have a smaller influence on the BCR than on the ovalization, without necessarily following the same trend, at all investigated footing setbacks. These hypotheses are examined with the parametric finite element results, with the footing setback defined relative to the slope crest.
To address these questions and hypotheses, the PLAXIS 2D model was compared with the measured footing load–settlement response and bearing capacities from nine reduced-scale laboratory tests, including configurations with and without a buried PVC pipe. Eight tests were within the parameter range of the numerical study, while one test (b/B = 2) was retained as an out-of-range comparison. The laboratory tests did not provide direct measurements of pipe ovalization or bending moment; therefore, the validation was limited to the footing response. A parametric study of 390 analyses was then carried out, covering three slope angles (20°, 30° and 35°), five footing setbacks (b/B = 0–1), five burial depths (H/D = 1–4) and five pipe stiffness levels (EI/EI0 = 0.25–4). GP and ANN surrogates were trained on the results and assessed with cross-validation, including a test in which entire slope–setback groups were withheld. The surrogates were finally used to optimize pipe depth and stiffness under single- and bi-objective formulations (cost and pipe ovalization, with the bearing capacity ratio as a constraint). Metaheuristic algorithms (GA, PSO, DE, NSGA-II, NSGA-III, SPEA2, MOEA/D and MOPSO) were compared against random sampling under matched evaluation budgets, while exhaustive surrogate-grid evaluations were used to establish reference optima and Pareto fronts. Because the bearing capacity ratio is predicted less accurately than the pipe response, the numerical reliability of this constraint was examined separately, and selected optimal designs were verified with independent finite element analyses.
The remainder of the paper is organized as follows. Section 2 describes the methodology: the model tests and numerical model, the parametric dataset, the surrogate models and the optimization formulations. Section 3 presents and discusses the results, including the limitations of the study, and Section 4 summarizes the conclusions.

2. Materials and Methods

The study combined laboratory model tests, finite element analyses, surrogate models and optimization, as summarized in Figure 1.
Figure 1. Workflow of the study.

2.1. Model Tests and Numerical Model

Nine laboratory model tests (SPU1–SPU9) from the thesis of the first author [36] were used to validate the numerical model; the same test setup was also used for geogrid-reinforced slopes in [37]. The tests serve here only for validation. The tests were performed in a 100 × 50 × 45 cm box with 2 cm transparent Plexiglas walls. A 30° sand slope was built with a slope-forming apparatus from Kilyos sand placed in layers and compacted with a vibrator (Bosch, Gerlingen, Germany) to a relative density of Dr = 65%. The sand was poorly graded (SP) with D50 = 0.26 mm, Cu = 1.24, Gs = 2.66, a dry unit weight of 16.76 kN/m3 and φ′ = 38°. A PVC pipe of outer diameter D = 50 mm was buried beneath a rigid steel strip footing (45 × 5 × 2.5 cm, B = 5 cm). The sand was placed in layers and compacted with the vibrator up to the invert level of the pipe, the pipe was placed, and the placement was continued with the same layer thickness and the same compaction. The amount of sand required for each layer was calculated from the target density and weighed before placement, and the same procedure was applied in all tests. The footing load was measured with a 2 t load cell (SBA-2T, CAS Corporation, Yangju, Republic of Korea) and the settlement with two LVDTs placed symmetrically on the footing. The test program (Table 1) varied the burial depth H/D and the footing setback b/B; SPU1, SPU5 and SPU9 were performed without a pipe. SPU9 (b/B = 2) lies outside the range of the parametric study (b/B ≤ 1); it is reported as an out-of-range test and is not included in the error statistics of the validation.
Table 1. Model test program (β = 30°, D = B = 50 mm; –: test without a pipe).
The tests were modeled in PLAXIS 2D under plane-strain conditions with 15-node triangular elements. The sand was represented by the Hardening Soil model with c′ = 0.32 kPa, φ′ = 38° and ψ = 8°; the full set of material parameters of the sand, the footing and the pipe is listed in Table 2. The footing and the pipe were modeled as plate elements, and interface elements with a strength reduction factor Rinter = 0.5 were placed along the outer surface of the pipe. The model was discretized with a fine global mesh without local refinement. Mesh sensitivity was examined for the configuration with the strongest pipe effect (β = 30°, b/B = 0, H/D = 1, EI/EI0 = 1) using the five global mesh densities of PLAXIS, from 119 to 1350 elements (Figure 2). The pipe response converged rapidly: between the fine mesh (789 elements) and the finest one, DRv and Mmax differed by only 1.2% and 1.6%. The ultimate capacity was more mesh-dependent and decreased by 10% between these two meshes, as is typical of collapse loads computed with finite elements. The fine mesh was adopted for all analyses. The mesh dependence was examined further at the optimal designs: when the three designs obtained with the safety margin (Section 3.5) and the corresponding unpiped analyses were recomputed with the finest mesh, qult decreased by 0.5–4.9%, DRv and Mmax changed by less than 1%, and the BCR changed by no more than 0.04, remaining above 1 in all three cases. The mesh enters the optimization only through the BCR constraint, because the cost depends on the design variables alone and all algorithms were compared on the same surrogate; the safety margin introduced in Section 3.5 exceeds this change. The footing was loaded by a prescribed vertical displacement. The same parameter set was used for all tests.
Table 2. Material parameters used in the PLAXIS 2D analyses.
Figure 2. Mesh sensitivity for β = 30°, b/B = 0, H/D = 1, EI/EI0 = 1: (a–e) the five mesh densities and (f) qult, DRv and Mmax normalized by their values with the finest mesh.

2.2. Parametric Dataset

The numerical model, validated against the measured footing response (Section 3.1), was used for a parametric study of 390 analyses, in which the slope angle, the footing setback, the burial depth and the pipe stiffness were varied in a full factorial design, together with one analysis without a pipe for each combination of β and b/B (Table 3). The setback b was measured from the slope crest; at b/B = 0 the footing edge was placed 1 cm inside the crest to avoid the stress singularity at the crest corner. The pipe was always centered beneath the footing, and H denotes the depth of the pipe crown below the footing base. The stiffness levels were obtained by scaling the wall thickness of the reference pipe (t0 = 2 mm, E = 3000 MPa) as t = t 0 E I / E I 0 1 / 3 which gives the axial and flexural stiffnesses of the plate elements. For D = 50 mm, the levels EI/EI0 = 0.5–4 (t = 1.6–3.2 mm) correspond to commercial unplasticised PVC (PVC-U) pipes from SDR 33 to SDR 17 in EN ISO 1452-2 [38], the reference pipe (t = 2.0 mm) to SDR 26, while EI/EI0 = 0.25 (t = 1.26 mm) represents a very flexible lower bound below the thinnest standard wall. Each analysis consisted of an initial phase in which the in situ stresses were generated by gravity loading, which is appropriate for a sloping ground surface, a plastic nil-step to ensure that the initial stress state was in equilibrium, a phase in which the pipe was activated, and a loading phase in which a vertical displacement of 3 mm (s/B = 6%) was prescribed to the footing with displacements reset to zero.
Table 3. Parametric analysis program (model scale, D = B = 50 mm).
Results were extracted automatically using the PLAXIS Python remote-scripting interface (PLAXIS 2D, version 2024.2) and processed with the same rules for all analyses. The footing pressure was computed as q = |ΣFy|/B. The ultimate bearing capacity qult was taken as the first peak of the load–settlement curve, defined as the maximum load reached before the load dropped by more than 10%; when no such drop occurred, qult was taken as the maximum load of the analysis. Of the 390 analyses, 299 showed a peak followed by a drop of more than 10% and 70 a flatter maximum before the end of loading; the settlement at qult had a median of s/B = 3.5% and was below 5.7% in 95% of the analyses. In 7 analyses, the calculation stopped before the prescribed displacement was reached because the load advancement procedure failed, and the maximum computed load was taken; in 3 of these the load was still increasing over the last steps. In the remaining 14 analyses, all with a pipe and none at β = 35°, the load was still increasing at the prescribed displacement, and qult is the pressure at s/B = 6%; in these analyses the load increased by 0.3–4.1% (2.0% on average) between s/B = 5% and 6%. The influence of this limit on the BCR was evaluated by applying a limit of s/B = 5% to all analyses: the BCR changed by more than 0.005 in 37 of the 375 analyses with a pipe, by 0.002 on average and by 0.07 at most. The bearing capacity ratio was defined as BCR = qult/qult,0, where qult,0 is the capacity without a pipe for the same β and b/B. Pipe response was evaluated at a service pressure of qs = 5 kPa, about half of the lowest capacity in the dataset. This pressure corresponds to a factor of safety against bearing failure of 1.8–6.1 in the 390 analyses (3.3 at the median); a single value was used so that the pipe response of all designs is compared under the same footing pressure. The vertical and horizontal diameter changes (%) were computed as
D R v = | Δ u c r o w n − Δ u i n v e r t | / D × 100
D R h = | Δ u r i g h t − Δ u l e f t | / D × 100
where Δucrown, Δuinvert, Δuright and Δuleft are the displacements of the crown, invert and springline points of the pipe in the loading direction considered, and D is the pipe diameter. The maximum bending moment Mmax was also recorded, from which the maximum wall bending stress was computed as σmax = 6 Mmax/t2.

2.3. Surrogate Model

Surrogate models were trained to predict qult, DRv and Mmax from four inputs: β, b/B, H/D and log2(EI/EI0). The outputs were log-transformed because DRv and Mmax vary by up to an order of magnitude across the dataset. Two model types were compared. The Gaussian process (GP) used a Matérn kernel (ν = 5/2) with a separate length scale for each input and a white-noise term, so that the numerical scatter of the collapse loads is treated as noise rather than fitted; hyperparameters were obtained by maximizing the marginal likelihood with five random restarts. The artificial neural network (ANN) was an ensemble of five multilayer perceptrons with two hidden layers of 16 tanh neurons, trained with L-BFGS and L2 regularization from different initializations, whose predictions were averaged. Inputs and outputs were standardized, and both models were implemented in scikit-learn (version 1.9.1) [39]. The L2 regularization parameter of the ANN was 10−3 and the training was limited to 5000 iterations; the five networks were initialized with the seeds 0–4. The length scales of the GP were bounded between 10−2 and 103 and the noise variance between 10−6 and 1 (standardized variables), and the folds of the 10-fold cross-validation were drawn with a fixed seed. BCR was not modeled directly but derived as the ratio of the predicted qult to the qult,0 predicted by a separate GP fitted to the unpiped analyses, which avoids propagating the scatter of a single reference analysis to an entire group.
Accuracy was assessed in two ways. In 10-fold cross-validation, the data were split at random. In leave-one-group-out validation, each combination of β and b/B, including its unpiped analysis, was withheld in turn, so the model predicted a slope–setback configuration it had never seen. The coefficient of determination R2, the root-mean-square error, the mean and maximum absolute percentage errors are reported. Because the slope and setback dominate qult, a within-group R2 was also computed from deviations about each group’s mean; it measures how well the surrogate reproduces the effect of pipe depth and stiffness alone.

2.4. Optimization Formulation

The design variables were the burial depth H/D ∈ [1, 4] and the pipe stiffness log2(EI/EI0) ∈ [−2, 2], which were treated as continuous. The slope angle and setback were treated as site conditions, so each of the 15 combinations of β and b/B formed a separate design scenario. The relative cost of a design was defined as
C = w 1 H / D + 1 3 + w 2 E I / E I 0 1 / 3
where the first term represents excavation and backfill, which grow with burial depth, and the second the pipe material, which grows with wall thickness; with w1 = w2 = 0.5, the reference design (H/D = 2, EI/EI0 = 1) has C = 1. Equal weights were adopted as a neutral choice, since the ratio of excavation to pipe material costs depends on the project; the sensitivity of the optimal designs to the weights and to the form of the cost function is examined in Section 3.5. The wall stress was limited in all formulations to the design stress of PVC pipes, σmax ≤ MRS/Cd = 25/2.5 = 10 MPa, where Cd = 2.5 is the design coefficient of EN ISO 1452-2 [38] for diameters up to 90 mm. MRS is the long-term (50-year) strength of the material, so this limit refers to long-term rather than short-term strength. It was applied to the bending stress computed from Mmax; the ring compression stress and the time-dependent deformation of the pipe were not modeled. The standard defines this design stress for the hoop stress caused by internal pressure; it is adopted here as a limit for the bending stress caused by the external load, which is a conservative assumption for short-term loading, since the tensile strength of PVC pipe material is about 49 MPa [40]. Two formulations were considered:
  • Single-objective: minimize C subject to DRv ≤ DRv,ref and BCR ≥ 1.0, where DRv,ref is the ovalization of the reference design in the same scenario; that is, the cheapest design whose pipe ovalization does not exceed that of the reference and that does not reduce the capacity of the footing.
  • Bi-objective: minimize C and DRv subject to BCR ≥ 1.0. BCR was treated as a constraint rather than an objective for two reasons. First, the design requirement is that the pipe should not weaken the footing, so any design with BCR ≥ 1 is acceptable for the footing. Second, BCR is the output that the surrogate predicts least accurately (Section 3.3); as an objective, its prediction error would steer the whole search, whereas as a constraint it only needs to be resolved near BCR = 1.
The single-objective problem was solved with a genetic algorithm (GA), particle swarm optimization (PSO) [41] and differential evolution (DE) [42], each with 20 individuals and 1000 evaluations. The bi-objective problem was solved with NSGA-II, NSGA-III, SPEA2, MOEA/D and MOPSO with a crowding-distance archive [43], each with a population or archive of 50 and 5000 evaluations. Constraints were handled in all algorithms with the same static penalty,
F i = f i + P δ + v v = m a x 0 , 1 − B C R + m a x 0 , σ m a x / σ a l l o w − 1 + m a x 0 , D R v / D R v , r e f − 1
where fi is the i-th objective, v is the total constraint violation, δ = 1 for a design that violates any constraint and δ = 0 otherwise, σallow = 10 MPa, and P = 10 for the single-objective and P = 100 for the bi-objective problem; the last term of v applies only to the single-objective problem. The step term δ ensures that every infeasible design is ranked behind every feasible one. In the bi-objective problem, both objectives were scaled to about [0, 1] with the same a priori ranges in all algorithms, and the final approximation sets were reduced to 50 solutions.
Random sampling with the same budget served as a baseline, and a reference optimum and a reference Pareto front were obtained by exhaustive evaluation of the surrogate on fine grids (801 × 801 and 201 × 201 points). These are grid-based approximations of the continuous optimum: the grid spacing of the single-objective problem is 0.00375 in H/D and 0.005 in log2(EI/EI0), which corresponds to about 0.1% of the cost. Each algorithm was run 30 times per scenario. Performance was measured by the gap to the optimum cost, the success rate (gap < 0.5%) and the number of evaluations needed to come within 1% of the optimum for the single-objective problem, and by the hypervolume [44] and IGD+ [45] relative to the reference front for the bi-objective problem. In each scenario, the 30 final results of every algorithm were compared with those of the best algorithm (lowest mean gap or highest mean hypervolume) using the two-sided Wilcoxon rank-sum test, and the p-values were adjusted for multiple comparisons with the Holm–Bonferroni method. An algorithm was counted as best or statistically equal to the best when the adjusted p-value was at least 0.05. The scenarios were not pooled in the test; instead, the number of scenarios in which each algorithm was best or equal is reported (Section 3.4). The algorithms were implemented with pymoo [46], except MOPSO, which was implemented following Raquel and Naval [43]. The algorithm settings were as follows. GA used binary tournament selection, simulated binary crossover (SBX; probability 0.9, η = 15) and polynomial mutation (PM; η = 20); PSO used an inertia weight of 0.9 and c1 = c2 = 2.0 with adaptive parameter control and a maximum velocity of 20% of the variable range; DE used the DE/rand/1/bin scheme with F = 0.8 and CR = 0.9. NSGA-II and SPEA2 used SBX (probability 0.9, η = 15) and PM (η = 20), and NSGA-III SBX (probability 1.0, η = 30) and PM (η = 20) with 50 Das–Dennis reference directions. MOEA/D used 50 weight vectors, the Tchebycheff decomposition, 15 neighbors, a neighborhood mating probability of 0.7, SBX (probability 1.0, η = 20) and PM (η = 20). MOPSO used w = 0.4, c1 = c2 = 1.5 and a mutation probability decreasing as (1 − t/T)2, where t is the iteration and T the number of iterations. All other settings were the defaults of pymoo 0.6.2, and no algorithm was tuned to the problem. The budget was exactly 1000 evaluations (20 individuals × 50 generations) for the single-objective problem and 5000 evaluations (50 × 100) for the bi-objective problem, including the initial population. The run index (0–29) was used as the random seed, so that all algorithms were started from the same set of seeds.

2.5. Selection of a Compromise Design

The bi-objective problem yields a set of Pareto-optimal designs rather than a single solution. A compromise design was selected for each scenario with the ideal point method, as in Alnmr et al. [35]. The two objectives of the reference Pareto front were normalized as
f ¯ i = f i − f i , m i n f i , m a x − f i , m i n
where fi,min and fi,max are the minimum and maximum values of objective i on the front. In this normalized space, the ideal point, which combines the lowest cost and the lowest ovalization on the front, lies at the origin, and the design with the smallest Euclidean distance to the origin was selected as the compromise design. With equal weights this design represents a balanced trade-off between cost and pipe ovalization; other weights would move it along the front.

3. Results and Discussion

3.1. Validation of the Numerical Model

Figure 3 compares the measured and computed load–settlement curves, and Table 4 lists the ultimate bearing capacities and bearing capacity ratios. All nine tests were analyzed with the same set of soil parameters (Section 2.1).
Figure 3. Comparison of the reduced-scale model tests SPU1–SPU8 with PLAXIS 2D: load–settlement curves for (a) b/B = 0 and (b) b/B = 1 (computed curves shown up to qult), (c) measured and computed ultimate bearing capacities and (d) bearing capacity ratios of the tests with a pipe. The legend in (b) also applies to (a); the dashed line in (d) marks BCR = 1.
Table 4. Comparison of the measured and computed footing response in the reduced-scale model tests (single parameter set).
For tests SPU1–SPU8, the computed capacities differ from the measured ones by 11.8% on average and by at most 32.4% (SPU2), where the difference is defined as (qnum − qexp)/qexp × 100. The unpiped tests are reproduced within 6.3%. The model also reproduces the main experimental trends: the capacity increases with footing setback and with burial depth, and the shallowest pipe (H/D = 1) causes the largest reduction. The computed BCRs (0.83–1.02) are, however, mostly higher than the measured ones (0.62–1.01), that is, the model underestimates the reduction in capacity caused by the pipe, most markedly for the shallowest pipe at the crest (BCR 0.88 against 0.62 for SPU2).
The origin of this deviation was examined with 14 additional analyses of the validation tests, in which one parameter was changed at a time (Table 5). The analyses were limited to the two series that lie within the range of the parametric study (b/B = 0 and 1) and, among the tests with a pipe, to H/D = 1 and 2, where the deviation is largest; the influence of the interface at greater depth is examined on the optimal designs in Section 3.5. The dilatancy angle was halved (ψ = 4°) in all six tests, including the unpiped ones, because it affects the soil with and without a pipe. The interface strength was varied between a weak interface (Rinter = 0.3) and a fully rough one (Rinter = 1.0), which bracket the reference value of 0.5; this was done in the four tests with a pipe only, since the interface exists only on the pipe surface. With ψ = 4°, the computed capacities of the unpiped tests fell to 34–37% below the measured values, against 1–6% with ψ = 8°, which supports the adopted value, while the BCRs changed by no more than 0.04. The interface strength had a larger influence on the BCR, particularly for the shallowest pipe (0.58–1.07 for SPU6). A weaker interface brings the model closer to the tests at b/B = 1 but not at b/B = 0, and no single value reproduced all four tests. The deviation could therefore not be removed by adjusting these parameters.
Table 5. Sensitivity of the validation analyses to the dilatancy angle and to the pipe–soil interface strength (one parameter changed at a time).
This bias has two consequences for the remainder of the study. First, it decreases with burial depth: the difference between the computed and the measured BCR was 0.26 and 0.09 at H/D = 1 (b/B = 0 and 1), 0.20 and 0.10 at H/D = 2, and 0.01 and 0.08 at H/D = 3. The computed BCR, and hence the constraint BCR ≥ 1 used in the optimization, is therefore not conservative, most clearly for pipes buried shallower than about two diameters. Second, the constraint should be understood as a requirement on the numerical model rather than as a guarantee for the physical system. For this reason, the numerical reliability of the constraint is examined separately in Section 3.5, where a safety margin is introduced and the resulting designs, which lie at H/D ≈ 3, are checked with independent finite element analyses, including analyses with Rinter = 0.3.
In addition, the model reaches the peak at smaller settlements than the tests, most visibly at b/B = 1 where the measured curves have flat peaks (settlement at qult 4.8–7.5 mm measured against 1.5–1.9 mm computed); the comparison is therefore based on capacities rather than settlements. SPU9 (b/B = 2) is underpredicted by 24% and lies outside the range of the parametric study, which was limited to b/B ≤ 1. Within these limits, the model was considered adequate for the comparative parametric study that follows, in which designs are compared with one another; the BCR values reported below should be read with this bias in mind. The pipe response was not measured in the model tests, which were designed to observe the response of the footing and the deformation mechanisms of the soil with particle image velocimetry [37]; the computed ovalization and bending moments could therefore not be compared with measurements, and the validation is restricted to the footing capacity. In model tests of a strip footing above a PVC pipe in level sand, Bildik and Laman [40] measured the hoop stresses of the pipe with strain gauges and found that they decreased markedly as the embedment ratio of the pipe increased. The decrease in the pipe response with burial depth obtained in the present analyses is consistent with this trend. The same procedure, validation against measured load–settlement curves of the footing followed by extraction of the pipe response from the numerical model, was followed by Khan and Shukla [15]. The pipe response reported below is therefore a numerical result. It is used mainly to compare designs with one another; the only absolute check, that of the wall stress, has a large margin under the service pressure (14% of the design stress, Section 3.2).

3.2. Effect of Slope Angle, Setback, Burial Depth and Pipe Stiffness

Figure 4 shows the pipe response at the service pressure for a footing at the crest (b/B = 0). The vertical diameter change DRv decreased monotonically with both burial depth and pipe stiffness in all 375 analyses with a pipe. Stiffness had the larger effect: at the shallowest depth (H/D = 1) and β = 35° (mean of the five setbacks), increasing EI/EI0 from 0.25 to 4 reduced DRv from 0.35% to 0.06%, a factor of about six, whereas increasing H/D from 1 to 4 reduced it by 61% for the most flexible pipe and by only 33% for the stiffest one. The benefit of deeper burial therefore depends on the pipe: a flexible pipe relies on the confinement of the surrounding soil, whose effect grows with depth, while a stiff pipe resists the footing load largely by its own bending stiffness. The horizontal diameter change was close to the vertical one (DRh/DRv = 0.91–0.98), so the pipe deformed into an almost symmetrical ellipse.
Figure 4. Computed pipe response at the service pressure qs = 5 kPa for a footing at the crest (b/B = 0): (a–c) vertical diameter change DRv and (d–f) maximum bending moment Mmax against burial depth for the five pipe stiffness levels. Numerical results at model scale (D = B = 50 mm); see Section 3.6 for the limits of transfer to the field. The legend in (a) applies to all panels.
Steeper slopes increased the ovalization, as the reduced lateral confinement on the slope side allows the pipe to deform more. For the most flexible pipe at H/D = 1, DRv was 0.23%, 0.30% and 0.35% at β = 20°, 30° and 35°; for the stiffest pipe, the corresponding values, 0.050–0.057%, hardly differed. Moving the footing away from the crest had a smaller effect, reducing the mean DRv from 0.119% at b/B = 0 to 0.110% at b/B = 1. Even the largest value, 0.40%, is more than an order of magnitude below the deflection limits commonly adopted for flexible pipes [3]; at failure of the footing, the largest DRv was 2.6%. For comparison, ASTM D3034 [47] recommends a deflection limit of 7.5% for PVC sewer pipes; the largest ovalization was thus about 5% of this limit at the service pressure and about 35% at failure of the footing. In the optimization, DRv is therefore used as a relative measure of pipe performance for comparing designs at the scale of the model, rather than as a check against a deflection limit.
The dependence of the ovalization on pipe stiffness follows the form of the modified Iowa formula [2,3], in which the deflection is proportional to 1/(EI + 0.061 E′ r3), where r is the pipe radius and E′ the modulus of soil reaction. Fitting this expression to the five stiffness levels of each of the 75 slope–setback–depth configurations reproduced the computed DRv with R2 ≥ 0.998 and a median error of 1.8% (maximum 7%). The back-calculated E′ ranged from 1.0 to 3.1 MPa. It increased with burial depth, decreased with slope angle (mean values of 2.2, 1.8 and 1.6 MPa at β = 20°, 30° and 35°) and increased slightly with setback, consistent with the role of lateral confinement in the formula. The modulus of soil reaction is an empirical quantity that depends on the type of soil and its degree of compaction [5]; the present results indicate that, beneath a footing near a slope, it also depends on the burial depth and the slope angle. The numerical model thus reproduces the established stiffness dependence of flexible pipes also outside the range of the model tests, and the slope enters this classical description mainly through a reduced modulus of soil reaction.
The bending moment showed the opposite dependence on stiffness (Figure 4d–f): a stiffer pipe attracts more moment, which increased by a factor of about 2.3 from EI/EI0 = 0.25 to 4 at H/D = 1, and decreased with depth. Because the wall thickness enters the bending stress as t2, the stress was nevertheless largest in the most flexible pipes. The largest wall stress at qs was 1.4 MPa, and even at failure of the footing it did not exceed 9.3 MPa (β = 20°, b/B = 1, H/D = 1, EI/EI0 = 0.25), below the design stress of 10 MPa. The stress constraint was therefore never active in the optimization, and the pipe design is governed by its deformation rather than its strength. Buckling was checked with the classical expression for an unsupported ring, pcr = 2E/(1 – ν2)·(t/D)3 [48]: for the most flexible pipe (t = 1.26 mm) pcr ≈ 110 kPa, more than three times the highest footing pressure in the dataset (30 kPa) and about 20 times the service pressure, without any contribution from the surrounding soil. At failure of the footing, the largest wall stress decreased from 9.3 MPa for EI/EI0 = 0.25 to 6.2, 4.3, 2.8 and 1.9 MPa for EI/EI0 = 0.5, 1, 2 and 4, and from 9.3 MPa at H/D = 1 to 4.6 MPa at H/D = 1.75. To identify the conditions under which the limit is exceeded, three additional analyses were carried out with a pipe stiffness below the investigated range (EI/EI0 = 0.125, wall thickness 1.0 mm) at H/D = 1 and b/B = 1; these analyses were not used for the surrogates or the optimization. At failure of the footing, the wall stress was 11.3, 9.4 and 8.8 MPa for β = 20°, 30° and 35°, against 9.3, 6.7 and 5.7 MPa for EI/EI0 = 0.25. The stress constraint therefore becomes binding only for a pipe more flexible than the investigated range, at the shallowest burial depth and under a footing pressure at the bearing capacity (β = 20°).
These stress and buckling checks are preliminary numerical assessments under short-term static loading. The design stress is derived from the long-term strength under internal pressure and is used here only as a reference value for the bending stress caused by the external load, the buckling pressure is that of an unsupported ring, and the ring compression stress and the time-dependent deformation of the pipe were not modeled. The checks therefore do not constitute a verification of the long-term structural safety of the pipe.
Without a pipe, the bearing capacity decreased with slope angle and increased with setback, from 21.2–27.5 kPa at β = 20° to 13.6–18.1 kPa at 30° and 10.6–15.0 kPa at 35° for b/B = 0–1. Shallow pipes reduced this capacity: at H/D = 1, BCR was below 1 in all but one of the 75 analyses (mean 0.93–0.94 for the three slope angles), and at H/D = 1.75 in 79% of them. From H/D = 2.5 onwards, the pipe generally no longer reduced the capacity of the footing (BCR < 1 in 20%, 9% and 3% of the analyses at H/D = 2.5, 3.25 and 4). Since D = B in this study, the computed capacity was thus no longer reduced once the pipe crown lay more than about two footing widths below the footing base, which is smaller than the depth of at least three footing widths recommended by Khan and Shukla [13] from model tests; the design recommendation is given in Section 3.5. The reduction at H/D = 1.75 was largest for the steepest slope (mean BCR 0.94 at β = 35° against 0.99 at β = 20°), and the pipe stiffness had little influence on it.
All analyses of the parametric study had a pipe diameter equal to the footing width (D = B). To illustrate the influence of this ratio, four additional analyses were carried out for β = 30° and b/B = 0.5 with pipe diameters of 25 and 75 mm (D/B = 0.5 and 1.5, wall thicknesses of 1 and 3 mm, that is, the same ratio of diameter to wall thickness as the reference pipe) and with the pipe crown at depths of 1 and 2.5 footing widths below the footing base (H/B = 1 and 2.5); these analyses were not used for the surrogates or the optimization. At H/B = 1, the BCR was 1.01, 0.96 and 0.95 for D/B = 0.5, 1 and 1.5, and at H/B = 2.5 it was 1.04, 1.05 and 1.03. At the shallow depth the bearing capacity was thus reduced by the pipes with D/B = 1 and 1.5 but not by the smallest pipe, whereas at H/B = 2.5 it was not reduced for any of the three diameters.

3.3. Accuracy of the Surrogate Models

Table 6 and Figure 5 summarize the accuracy of the surrogate models. Both models reproduced the pipe response with high accuracy: for DRv and Mmax, R2 exceeded 0.999 and the mean error was below 1% in both cross-validation schemes, including the configurations withheld as entire groups. This accuracy is measured against the finite element results: it describes how well the surrogates reproduce the numerical model, not the physical accuracy of the model itself, which could not be assessed for the pipe response (Section 3.1). This high accuracy for the pipe response reflects the smooth dependence of the pipe response on the inputs (Figure 4). The ultimate capacity was also predicted with R2 = 0.98–0.99, but most of its variance stems from the slope angle and setback. Within a slope–setback group, where only the pipe depth and stiffness vary, R2 dropped to 0.73–0.81, and BCR was predicted with R2 = 0.73 in 10-fold cross-validation and only 0.38 in leave-one-group-out validation, with mean errors of 2.8–4.3%. These errors are of the same order as the numerical scatter of the collapse loads, which the white-noise term of the GP estimated at about 2% of qult, so the surrogate cannot resolve the small effect of the pipe on the capacity more precisely than the finite element analyses themselves. The GP was clearly more accurate than the ANN for qult and BCR, whereas for the pipe response the two models were practically equivalent; the GP was therefore used in the optimization.
Table 6. Accuracy of the surrogate models in 10-fold cross-validation (CV) and leave-one-group-out validation (LOGO).
Figure 5. Surrogate predictions against the PLAXIS 2D results in 10-fold cross-validation and leave-one-group-out validation for the GP (left) and ANN (right) surrogates: (a,b) qult, (c,d) BCR, (e,f) DRv at qs and (g,h) Mmax at qs. The line indicates perfect agreement.
Figure 6 shows SHAP values [49] of the GP surrogate, which attribute each prediction to the four inputs. The pipe stiffness dominated both DRv and Mmax, with opposite signs, followed by the burial depth; the slope angle increased both, and the setback had only a minor effect. The capacity of the footing was governed by the slope angle and the setback, while BCR depended mainly on the burial depth. These rankings agree with the trends of the finite element results, which suggests that the surrogate captures the main physical trends of the dataset.
Figure 6. SHAP summary of the GP surrogate for (a) qult, (b) BCR, (c) DRv and (d) Mmax. Each point is one analysis; the color shows the value of the input.

3.4. Optimization Results and Comparison of Algorithms

Single-objective problem. The reference optimum on the 801 × 801 grid cost between 0.95 and 1.06 times the reference design, and only 31–50% of the design space was admissible in each scenario. Table 7 and Figure 7 compare the algorithms over 30 runs in each of the 15 scenarios. All three metaheuristics located the optimum: PSO and DE in every run and GA in 98% of the runs, with mean gaps below 0.1%. The small negative mean gaps of PSO and DE arise because these algorithms search the continuous space and can slightly undercut the optimum of the finite grid. PSO converged fastest, reaching 1% of the optimum after a median of 127 evaluations, and was the best algorithm in all 15 scenarios according to the Wilcoxon test; the differences between PSO, DE and GA, however, are of the order of 0.1% of the cost and have no practical significance. Random sampling with the same budget was clearly inferior: it came within 0.5% of the optimum in only 9.6% of the runs, within 1% in 29% of them, and missed the optimum by 1.6% on average and by up to 5.4%. The reason is the location of the optimum, which lies on the boundary of the admissible region where the ovalization and capacity constraints are active; a random sample rarely falls close to such a boundary, whereas the metaheuristics are drawn towards it by the penalty.
Table 7. Single-objective optimization: gap to the grid-based reference optimum cost over 30 runs in 15 scenarios (1000 evaluations per run; success: gap < 0.5%; best or equal: not significantly worse than the best algorithm in the Wilcoxon rank-sum test with Holm correction, α = 0.05). Difference to PSO: mean difference of the gap to that of the best algorithm, with its 95% confidence interval over the 15 scenarios. * Median of the 29% of runs that came within 1%.
Figure 7. Single-objective optimization: (a) gap to the optimum cost against the number of surrogate evaluations (median and interquartile range over all runs and scenarios) and (b) final gap after 1000 evaluations. In (a), the lines show the median and the shaded areas the interquartile range; in (b), the circles are outliers lying more than 1.5 times the interquartile range from the box.
The thresholds used in Table 7 were set from the size of the corresponding design change: with equal weights, cost gaps of 0.5% (success) and 1% (convergence) correspond to differences of about 0.03 and 0.06 in H/D, that is, 1.5 and 3 mm for the model pipe. Table 7 and Table 8 also give the mean difference of each algorithm to the best one with its 95% confidence interval, which expresses the size of the effect in the units of the cost and of the hypervolume ratio.
Table 8. Bi-objective optimization (cost and DRv, BCR ≥ 1): hypervolume ratio and IGD+ relative to the exhaustive-grid front over 30 runs in 15 scenarios (5000 evaluations per run, 50 final designs). Difference to MOPSO: mean difference of the hypervolume ratio to that of the best algorithm, with its 95% confidence interval over the 15 scenarios.
Bi-objective problem. The reference Pareto fronts obtained from the 201 × 201 grid contained 405–477 designs. Table 8 and Figure 8 and Figure 9 show that all algorithms approximated them closely: the hypervolume of the final sets of 50 designs reached 98.5–98.9% of the reference value, and the fronts of all methods are visually indistinguishable (Figure 8a). Because a set of 50 points cannot reproduce the hypervolume of a front of more than 400 points exactly, about 99% is close to the attainable maximum. MOPSO and SPEA2 gave the highest hypervolume and the lowest IGD+; MOPSO was the best or statistically equal to the best algorithm in all 15 scenarios and SPEA2 in eight. Random sampling, however, reached a mean hypervolume ratio of 0.987, higher than NSGA-II (0.985) and equal to MOEA/D, and its IGD+ was lower than that of NSGA-II, NSGA-III and MOEA/D. Most of these differences were statistically significant but did not exceed 0.4% of the hypervolume. The metaheuristics converged faster (Figure 8b): SPEA2 and NSGA-II exceeded 98% of the reference hypervolume after about 750 evaluations, random sampling after about 1500, MOPSO converged at about the same rate as random sampling but ended highest, and MOEA/D was the slowest, probably because its fixed weight vectors adapt poorly to the strongly curved front.
Figure 8. Bi-objective optimization: (a) final fronts of the first run for β = 30°, b/B = 0.5 against the exhaustive-grid reference front and (b) hypervolume ratio against the number of surrogate evaluations (mean and standard deviation over all runs and scenarios). In (a), the fronts of all algorithms listed in the legend are plotted and largely overlap; in (b), the lines show the mean and the shaded areas ± one standard deviation, and the dashed line marks a hypervolume ratio of 1.
Figure 9. Final hypervolume ratio of the algorithms in the 15 design scenarios (30 runs each). The scenarios are numbered 1–15; the star marks the algorithm with the highest mean in each scenario and the open circle the algorithms that are not significantly lower (Wilcoxon rank-sum test with Holm correction, α = 0.05); all other algorithms are significantly lower.
The contrast between the two problems indicates when a metaheuristic was worthwhile in this study. In the constrained single-objective problem, the answer is a single point on the boundary of a narrow admissible region, and the metaheuristics found it with a precision that random sampling did not reach with the same budget. In the bi-objective problem, the answer is a curve, and with only two design variables and a smooth surrogate, 5000 random samples cover the admissible region densely enough that their non-dominated subset already traces the front. The choice among well-established algorithms mattered even less than the choice between a metaheuristic and random sampling. For the two-variable problem studied here, an exhaustive grid search of the surrogate took seconds to a minute per scenario and provided a useful reference for assessing the algorithms; metaheuristics can be expected to become more advantageous as the number of design variables grows or when each evaluation requires a finite element analysis.
Two aspects of these results should be distinguished: the numerical accuracy of the search and the numerical reliability of the resulting design. The differences among GA, PSO and DE are about 0.1% of the cost, or about 0.006 in H/D if taken up entirely by the burial depth. They are much smaller than the numerical uncertainties of the finite element model and the error of the predicted BCR, and have no engineering significance. The benefit of the metaheuristics lies instead in the reliability and efficiency of the search for the constrained optimum, which lies on the boundary of an admissible region covering only 31–50% of the design space. GA, PSO and DE located it in 98–100% of the runs with 1000 evaluations, against the 641,601 evaluations of the exhaustive grid, whereas random sampling with the same budget came within 0.5% of it in only 9.6% of the runs and missed it by up to 5.4%, a loss of the same order as the cost of the safety margin on the BCR constraint (4–10%, Section 3.5). The numerical reliability of the design, in turn, is governed by the accuracy of the constraint: the safety margin moved the optimal burial depth by 0.5–1.4 pipe diameters. A metaheuristic thus ensures that the optimum of the surrogate is found reliably and efficiently. The safety margin and the finite element verification reduce the risk that this optimum violates the constraint in the finite element model, but they do not establish the reliability of the design for the physical system.

3.5. Optimal Designs and Practical Recommendations

Figure 10 shows the bi-objective trade-off for b/B = 0.5. Along the front, the BCR constraint was active: every Pareto-optimal design up to the upper stiffness bound lay at BCR = 1, so the burial depth of an optimal design is the smallest depth at which the pipe does not reduce the capacity of the footing, and the ovalization is then controlled by the stiffness. Once the stiffness reaches its upper bound (EI/EI0 = 4, C ≈ 1.35–1.4), the front flattens, because additional cost can only buy depth, which reduces DRv little for a stiff pipe. The reference design lies on or slightly above the front: for the same cost, a stiffer pipe at a smaller depth limits ovalization more effectively than the reference combination.
Figure 10. Pareto fronts of the bi-objective problem (cost and DRv, BCR ≥ 1) for b/B = 0.5, colored by the pipe stiffness, with the ideal-point design and the reference design. Numerical results at model scale (D = B = 50 mm); see Section 3.6 for the limits of transfer to the field.
Figure 11 summarizes the optimal designs of all scenarios obtained with the constraint BCR ≥ 1. The single-objective optimum (Figure 11a–c) stayed close to the reference stiffness (EI/EI0 = 0.84–1.21). Where the reference design satisfied BCR ≥ 1 (7 of the 15 scenarios, 4 of them at β = 20°), the optimum was shallower and slightly stiffer and saved 0.2–4.9% of the cost. Where it did not, which was the case in eight scenarios, including four of the five at β = 35°, the optimum had to be deeper (H/D = 2.2–2.5) and was 1.9–5.5% more expensive than the reference. The ideal-point designs (Figure 11d–f) were stiffer, with EI/EI0 = 1.38–1.95, and reduced the ovalization by 22–29% relative to the reference design for a cost increase of 4–17%. Steeper slopes required deeper pipes: the mean H/D of the ideal-point designs was 1.9, 2.2 and 2.3 at β = 20°, 30° and 35°. In terms of standard pipes, the single-objective optima correspond to a wall thickness of 1.9–2.1 mm, close to SDR 26, and the ideal-point designs to 2.2–2.5 mm, close to SDR 21 in EN ISO 1452-2 [38].
Figure 11. Optimal designs in the 15 scenarios: (a–c) single-objective optimum (burial depth, stiffness and cost saving relative to the reference design) and (d–f) ideal-point design of the bi-objective problem (burial depth, stiffness and cost). All designs were obtained with the constraint BCR ≥ 1. Numerical results at model scale (D = B = 50 mm); see Section 3.6 for the limits of transfer to the field.
The sensitivity of these designs to the cost function was examined by repeating the grid search with other weights (w1 = 0.3 and 0.7) and with two other forms of the cost function, in which the excavation term or the pipe term was squared. The single-objective optimum was unchanged (H/D within 0.05 and EI/EI0 within 5%) in all 15 scenarios for w1 = 0.7 and for both alternative forms, and in 12 scenarios for w1 = 0.3; in the remaining three, at β = 35° and b/B ≤ 0.5, it moved to the deepest burial with a flexible pipe (H/D = 4, EI/EI0 = 0.34–0.37), which with these weights was cheaper than the shallower design by only 0.1–1.2%, whereas with equal weights it was 14–16% more expensive; the two designs had the same cost at w1 ≈ 0.31. The burial depth of the ideal-point designs changed by at most 0.09, whereas their stiffness depended on the cost function: EI/EI0 = 1.21–1.56 for w1 = 0.3, 1.56–2.75 for w1 = 0.7, 1.65–2.83 with the squared excavation term and 1.30–1.67 with the squared pipe term, against 1.38–1.95 in the reference case. The required burial depth is therefore insensitive to the cost assumptions, whereas the selected pipe stiffness is not.
The weights of the cost index can be read as a cost ratio: w1 = 0.3, 0.5 and 0.7 correspond to ratios of the excavation and backfill cost to the pipe material cost of 0.43, 1 and 2.33 for the reference design. With w1 = 0.3 and 0.7, the ideal-point designs reduced the ovalization by 13–22% and 30–43% for cost increases of 6–12% and 1–20%, against 22–29% and 4–17% with equal weights. Because commercial pipes are available only in discrete classes, the search was also repeated with the stiffness restricted to the four levels corresponding to SDR 33, 26, 21 and 17 (EI/EI0 = 0.5, 1, 2 and 4). The single-objective optimum then used SDR 26 in all 15 scenarios (H/D = 2.0–2.5), with a cost 0.2–5.1% above the continuous optimum, and the ideal-point design used SDR 21 in all 15 scenarios, with a burial depth (H/D) within 0.11 of the continuous design and a cost 0.6–8.0% higher.
The ideal-point designs of the three slope angles at b/B = 0.5 were verified with additional PLAXIS 2D analyses (Table 9). The surrogate predicted the pipe response of these unseen designs closely, with differences of at most 0.6% in DRv and 0.4% in Mmax. The computed BCR was 1.05, 1.01 and 0.99 against the predicted value of 1.00, which is within the accuracy of the surrogate for BCR (Table 6); at β = 35° the capacity requirement was missed by 1.5%.
Table 9. Verification of the ideal-point designs obtained with the constraint BCR ≥ 1 for b/B = 0.5 with PLAXIS 2D. Numerical results at model scale (D = B = 50 mm); see Section 3.6 for the limits of transfer to the field.
The numerical reliability of the BCR constraint, that is, the extent to which the designs admitted by the surrogate also satisfy the constraint in the finite element model, was examined with the cross-validation predictions of the 375 analyses with a pipe. The error of the predicted BCR had practically no bias (mean below 0.002) and a standard deviation of 0.037 in 10-fold cross-validation and 0.056 in leave-one-group-out validation; 95% of the errors were below 0.08 and 0.11, respectively. Of the analyses for which the surrogate predicted BCR ≥ 1, 9.9% (cross-validation) and 15.6% (leave-one-group-out) had a computed BCR below 1, the lowest values being 0.91 and 0.93. A constraint at BCR ≥ 1 is therefore violated by about one in ten to one in six of the designs it admits, as happened for β = 35° in Table 9.
A safety margin was therefore applied by raising the constraint to BCR ≥ 1.05; the margin of 0.05 corresponds to about one standard deviation of the prediction error. With this margin, the share of admitted analyses with a computed BCR below 1 fell to 3.4% and 7.8% in the two cross-validation schemes. In the 15 scenarios the ideal-point designs obtained with the margin were deeper than those obtained without it, with H/D = 2.4–3.3 (mean 2.9) against 1.5–2.6 (mean 2.1). This margin is a measure of numerical reliability: it reduces, but does not eliminate, the share of admitted designs that violate the constraint, and it refers only to the error of the surrogate with respect to the finite element model. It is not an independently established engineering safety factor, and it does not cover the difference between the numerical model and the model tests (Section 3.1).
The three designs obtained with the margin for b/B = 0.5 were analyzed with PLAXIS 2D (Table 10). The computed BCR was 1.07, 1.10 and 1.05, so all three designs satisfied BCR ≥ 1, and the pipe response was predicted within 0.2% for both DRv and Mmax. Compared with the designs in Table 9, the pipes are 0.5–0.8 diameters deeper and less stiff (EI/EI0 = 1.13–1.43 against 1.43–1.67), and the cost is 4–10% higher. The three designs were also recomputed with a weaker pipe–soil interface (Rinter = 0.3) and, together with the corresponding unpiped analyses, with the finest mesh. The BCR was 1.08, 1.06 and 1.02 with Rinter = 0.3 and 1.07, 1.07 and 1.08 with the finest mesh, and DRv and Mmax changed by less than 2%.
Table 10. Verification of the ideal-point designs obtained with the safety margin (BCR ≥ 1.05) for b/B = 0.5 with PLAXIS 2D. Numerical results at model scale (D = B = 50 mm); see Section 3.6 for the limits of transfer to the field.
The cost, DRv, Mmax and BCR of the six verified designs, as predicted by the surrogate and as computed with PLAXIS 2D, are listed together in Table 11. None of these designs coincides with a point of the training grid, so they also provide an independent test of the surrogate: the differences were at most 0.6% in DRv, 0.4% in Mmax and 0.05 in BCR.
Table 11. Cost, DRv, Mmax and BCR of the six verified ideal-point designs (b/B = 0.5) predicted by the GP surrogate and computed with PLAXIS 2D. The cost C depends on the design variables only and is therefore the same in both cases. Numerical results at model scale (D = B = 50 mm); see Section 3.6 for the limits of transfer to the field.
The three designs were also recomputed with a different stiffness of the sand around the pipe. In a square zone with a side of 2D centered on the pipe, the stiffness moduli of the Hardening Soil model (E50ref, Eoedref and Eurref) were halved and doubled, with all other parameters unchanged. The BCR was 1.10, 1.11 and 1.06 with the halved stiffness and 1.05, 1.08 and 1.00 with the doubled stiffness for β = 20°, 30° and 35°, against 1.07, 1.10 and 1.05 in the reference analyses, so the constraint BCR ≥ 1 remained satisfied in all cases.
The predictions of the BCR surrogate near the constraint were examined further. Of the analyses for which the surrogate predicted BCR < 1, 11.2% (cross-validation) and 19.2% (leave-one-group-out) had a computed BCR of 1 or more. For predicted values between 0.98 and 1.02, 90% of the computed values lay between 0.94 and 1.06 in both schemes, and the residuals showed no systematic trend with burial depth or slope angle (Figure 12). The margin of 0.05 is close to a constraint on the lower bound of the GP prediction: the posterior standard deviation of the predicted BCR was 4–5% over the design space, and requiring the prediction minus one standard deviation to be at least 1 gave ideal-point designs with a predicted BCR of 1.045–1.049. In the cross-validation of the surrogate, this lower bound left 3.9% and 9.1% of the admitted analyses with a computed BCR below 1 in the two schemes, against 3.4% and 7.8% with the fixed margin.
Figure 12. Residuals of the BCR predicted by the GP surrogate (predicted − computed) for the 375 analyses with a pipe, grouped by (a) burial depth and (b) slope angle; the bars show the mean and ± one standard deviation of each group. The legend in (a) also applies to (b).
For the configurations investigated, these results indicate a crown depth of about three footing widths below the footing base, with the ovalization controlled through the pipe stiffness rather than by deeper burial. This depth corresponds to the designs obtained with the safety margin (H/D = 2.4–3.3), three of which, all for b/B = 0.5, were verified and satisfied BCR ≥ 1 in the finite element analyses (Table 10), and to the depth recommended by Khan and Shukla [13] from model tests. It also takes into account the model tests, in which the capacity at H/D = 3 was not reduced at b/B = 0 (BCR = 1.01) but was still reduced at b/B = 1 (BCR = 0.87, Table 4). The depth is therefore an indicative value and not a generally applicable minimum requirement, and a project-specific verification of the selected design remains necessary.
These recommendations are subject to the conditions of the study. They were derived from two-dimensional plane-strain analyses, validated against the footing response measured in reduced-scale model tests under 1g conditions, for one sand at one relative density and a pipe diameter equal to the footing width (Section 3.6). They should therefore be read as indicative results for these conditions and not as design values for other soil conditions, pipe geometries, footing setbacks or full-scale applications.
The findings can be divided into those that confirm established behavior and those that are new. The first group comprises the decrease in the ovalization with pipe stiffness in the form of the modified Iowa formula [2,3], the decrease in the pipe response with burial depth [40], the decrease in the bearing capacity with slope angle and its increase with setback [7,8], and the reduction in the bearing capacity by shallow pipes [12,13]. The new findings concern the pipe stiffness, which was varied independently in this three-component system: in line with the two hypotheses of the study, the ovalization decreased with burial depth and pipe stiffness in all configurations, whereas the stiffness had a much smaller influence on the BCR. In addition, the modulus of soil reaction back-calculated beneath a footing near a slope was found to depend on the burial depth and the slope angle, and the error of the surrogate for the BCR constraint was quantified and partly covered by a safety margin. In conventional design, the deflection of a flexible pipe is checked with the modified Iowa formula [2,3,4] and an empirical modulus of soil reaction [5], a check that concerns the pipe alone. The framework used here does not replace this procedure; it uses the same response quantities and adds the bearing capacity of the footing as a constraint, so that the burial depth and the pipe stiffness are selected together with respect to cost.

3.6. Limitations of the Study

This study has several limitations. The analyses were two-dimensional, so the pipe and the footing were treated as infinitely long and three-dimensional effects at the ends of the footing were neglected. One sand at one relative density, one pipe diameter and one footing width were considered, and the model tests were performed at a reduced scale under 1g conditions, so stress-level effects need to be considered before the results are transferred to the field. The pipe response was not measured in the model tests, so the computed ovalization and bending moments have not been validated experimentally; model tests with instrumented pipes are needed for this purpose. Compared with the model tests, the numerical model underestimates the reduction in capacity caused by shallow pipes (Section 3.1), so the BCR values and the BCR ≥ 1 constraint are not conservative for shallow burial; the collapse loads also carry a numerical scatter of about 2% and depend on the mesh, which limits the precision with which the effect of the pipe on bearing capacity can be determined and predicted. The cost index represents relative rather than actual costs and depends on the chosen weights. Finally, six of the optimal designs, three obtained without and three with the safety margin, were verified by separate finite element analyses, all for b/B = 0.5; the designs of the other scenarios were not verified individually. The surrogates replace the finite element model only within the ranges of Table 3 and for the sand, pipe diameter and footing width of the model tests. As these properties are not inputs of the surrogates, they cannot be applied to other soils or geometries, and they were therefore tested with finite element analyses that were not used for training rather than with data from the literature.
Two of these limitations concern the geometry. The plane-strain model treats the footing and the pipe as infinitely long; in addition to the effects at the ends of the footing, pipe joints and the stress concentrations at them are therefore not represented. The pipe diameter was equal to the footing width in the model tests and in the parametric study, so the burial depths reported here apply to D = B. The additional analyses in Section 3.2 illustrate the influence of D/B for one slope angle and one setback only, and the results should not be generalized to other combinations of pipe and footing dimensions without further analyses.
The cost index C requires particular care in its interpretation. It is a dimensionless relative measure, normalized so that the reference design has C = 1, and it should not be interpreted as an absolute monetary cost. Its two terms represent only the increase in the excavation and backfill cost with burial depth and of the pipe material cost with wall thickness, and its weights were not calibrated against market prices of excavation or of PVC-U pipes; equal weights were adopted as a neutral assumption. The cost differences reported in Section 3.5 are therefore differences in this index and not in project cost. For a specific project, the weights should be determined from the unit costs of excavation, backfill and pipe supply of that project; the sensitivity analysis in Section 3.5 shows how the optimal designs change with the weights.

4. Conclusions

The response of a buried PVC pipe beneath a strip footing on a sand slope was studied with a PLAXIS 2D model validated against the footing response measured in reduced-scale laboratory model tests, a parametric study of 390 analyses, GP and ANN surrogates, and a comparison of optimization algorithms. The pipe ovalization and bending moments are numerical results that were not measured in the model tests, and stress-level effects need to be considered before the findings are transferred to the field. For the conditions investigated (one sand at one relative density, a pipe diameter equal to the footing width and reduced-scale model tests), the main conclusions are as follows.
(1)
Pipe ovalization decreased monotonically with burial depth and pipe stiffness, by a factor of six to ten within each slope–setback configuration, and increased with slope angle. Stiffness was the more effective of the two: the benefit of deeper burial was large for flexible pipes and small for stiff ones. The bending moment increased with stiffness, but the wall stresses at the service pressure remained far below the design stress of PVC, so the pipe design was governed by deformation. This is a preliminary check of the bending stress under short-term loading and not a verification of the long-term structural safety of the pipe.
(2)
Pipes with a crown depth of less than about two footing widths (H/D ≤ 1.75 with D = B) reduced the computed bearing capacity of the footing, most markedly on the steepest slope; deeper pipes generally did not. With a safety margin on the BCR constraint, the optimal designs lay at a crown depth of about three footing widths, and the three designs verified with finite element analyses satisfied BCR ≥ 1. This margin covers the prediction error of the surrogate with respect to the finite element model only and is not an engineering safety factor. The depth of about three footing widths is an indicative value for the configurations investigated and not a general minimum requirement: in the model tests, the bearing capacity at H/D = 3 was still reduced at b/B = 1, and a project-specific verification remains necessary.
(3)
From a methodological point of view, the surrogates reproduced the pipe response computed with the finite element model with high accuracy (R2 ≥ 0.999), including slope–setback configurations they had not seen. The effect of the pipe on bearing capacity was captured only moderately (R2 = 0.38–0.73 for BCR), because it is of the same order as the numerical scatter of the collapse loads. The GP was more accurate than the ANN for the bearing capacity and BCR and equivalent to it for the pipe response.
(4)
For the constrained single-objective problem, GA, PSO and DE found the cheapest admissible design within 0.1%, whereas random sampling with the same budget missed it by 1.6% on average. For the bi-objective problem, all algorithms and random sampling attained 98.5–98.9% of the reference hypervolume, and random sampling outperformed NSGA-II. For this two-variable problem, the formulations considered and the evaluation budgets used (1000 and 5000 evaluations), metaheuristics were therefore valuable when the optimum was a single point on a constraint boundary, but offered little over simple search when a smooth front was sought; reporting an exhaustive search of the surrogate as a baseline is recommended for similar low-dimensional problems.
(5)
Two sets of ideal-point designs should be distinguished. With the constraint BCR ≥ 1, the designs used pipes somewhat stiffer than the reference (EI/EI0 = 1.4–1.9, about SDR 21) at the smallest depth that keeps BCR ≥ 1 (H/D = 1.5–2.6), and reduced ovalization by about a quarter for a cost increase of 4–17%; deeper burial was required on steeper slopes. With the safety margin (BCR ≥ 1.05), on which the practical recommendation is based, the designs were deeper (H/D = 2.4–3.3), and the three designs of this set that were verified with finite element analyses had H/D = 2.8–3.0 and EI/EI0 = 1.1–1.4 (Table 10). Only six designs, three of each set and all for b/B = 0.5, were verified with separate finite element analyses. These designs are a comparative guide for the conditions investigated and require experimental or field validation before they are applied in practice.

Author Contributions

Conceptualization, H.N., S.B. and M.S.K.; methodology, H.N.; software, H.N.; validation, H.N.; formal analysis, H.N.; investigation, H.N.; resources, H.N.; data curation, H.N.; writing—original draft preparation, H.N.; writing—review and editing, S.B. and M.S.K.; visualization, H.N.; supervision, S.B. and M.S.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The data presented in this study and the Python scripts used for post-processing, surrogate modeling and optimization are available on request from the corresponding author.

Acknowledgments

During the preparation of this study, the authors used Claude (Anthropic, Claude Opus 5.5) solely for language editing of the manuscript. The authors have reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
ANNArtificial neural network
BCRBearing capacity ratio
CVCross-validation
DEDifferential evolution
GAGenetic algorithm
GPGaussian process
HVHypervolume
IGD+Inverted generational distance plus
L-BFGSLimited-memory Broyden–Fletcher–Goldfarb–Shanno
LOGOLeave-one-group-out
LVDTLinear variable differential transformer
MAPEMean absolute percentage error
MOEA/DMulti-objective evolutionary algorithm based on decomposition
MOPSOMulti-objective particle swarm optimization
MRSMinimum required strength
NSGA-IINon-dominated sorting genetic algorithm II
NSGA-IIINon-dominated sorting genetic algorithm III
PSOParticle swarm optimization
PVCPolyvinyl chloride
PVC-U Unplasticized polyvinyl chloride
SDRStandard dimension ratio
SHAPSHapley Additive exPlanations
SPPoorly graded sand (Unified Soil Classification System)
SPEA2Strength Pareto evolutionary algorithm 2

References

  1. Marston, A. The Theory of External Loads on Closed Conduits in the Light of the Latest Experiments; Bulletin 96; Iowa Engineering Experiment Station: Ames, IA, USA, 1930. [Google Scholar]
  2. Spangler, M.G. The Structural Design of Flexible Pipe Culverts; Bulletin 153; Iowa Engineering Experiment Station: Ames, IA, USA, 1941. [Google Scholar]
  3. Moser, A.P.; Folkman, S. Buried Pipe Design, 3rd ed.; McGraw-Hill: New York, NY, USA, 2008. [Google Scholar]
  4. Masada, T. Modified Iowa formula for vertical deflection of buried flexible pipe. J. Transp. Eng. 2000, 126, 440–446. [Google Scholar] [CrossRef] [Scilit]
  5. Howard, A.K. Modulus of soil reaction values for buried flexible pipe. J. Geotech. Eng. Div. 1977, 103, 33–43. [Google Scholar] [CrossRef] [Scilit]
  6. Elshimi, T.M.; Moore, I.D. Modeling the effects of backfilling and soil compaction beside shallow buried pipes. J. Pipeline Syst. Eng. Pract. 2013, 4, 04013004. [Google Scholar] [CrossRef] [Scilit]
  7. Meyerhof, G.G. The ultimate bearing capacity of foundations on slopes. In Proceedings of the 4th International Conference on Soil Mechanics and Foundation Engineering, London, UK, 12–24 August 1957; Butterworths Scientific Publications: London, UK, 1957; Volume 1, pp. 384–386. [Google Scholar]
  8. Keskin, M.S.; Laman, M. Model studies of bearing capacity of strip footing on sand slope. KSCE J. Civ. Eng. 2013, 17, 699–711. [Google Scholar] [CrossRef] [Scilit]
  9. Gao, Y.; Zhu, D.; Zhang, F.; Lei, G.H.; Qin, H. Stability analysis of three-dimensional slopes under water drawdown conditions. Can. Geotech. J. 2014, 51, 1355–1364. [Google Scholar] [CrossRef] [Scilit]
  10. Zhu, D.; Griffiths, D.V.; Fenton, G.A.; Huang, J.; Gao, Y. Reliability analysis of slopes under slow drawdown conditions. Géotechnique 2026, 76, 835–841. [Google Scholar] [CrossRef] [Scilit]
  11. Baus, R.L.; Wang, M.C. Bearing capacity of strip footing above void. J. Geotech. Eng. 1983, 109, 1–14. [Google Scholar] [CrossRef] [Scilit]
  12. Bildik, S.; Laman, M. Experimental investigation of the effects of pipe location on the bearing capacity. Geomech. Eng. 2015, 8, 221–235. [Google Scholar] [CrossRef] [Scilit]
  13. Khan, M.U.A.; Shukla, S.K. Load–settlement response and bearing capacity of a surface footing located over a conduit buried within a soil slope. Int. J. Geomech. 2020, 20, 04020173. [Google Scholar] [CrossRef] [Scilit]
  14. Zhu, H.-H.; Xie, T.-C.; Zhang, W.; Shukla, S.K. Numerical simulations of a strip footing on the soil slope with a buried pipe using the material point method. Int. J. Geomech. 2023, 23, 04023190. [Google Scholar] [CrossRef] [Scilit]
  15. Khan, M.U.A.; Shukla, S.K. Numerical investigation of the structural response of a conduit buried within a soil slope. Transp. Geotech. 2021, 30, 100614. [Google Scholar] [CrossRef] [Scilit]
  16. Khan, M.U.A.; Shukla, S.K.; Paraskeva, T.S. Stress distribution around the conduit buried within a soil slope—An experimental investigation. Transp. Geotech. 2022, 32, 100687. [Google Scholar] [CrossRef] [Scilit]
  17. Cocchetti, G.; di Prisco, C.; Galli, A.; Nova, R. Soil–pipeline interaction along unstable slopes: A coupled three-dimensional approach. Part 1: Theoretical formulation. Can. Geotech. J. 2009, 46, 1289–1304. [Google Scholar] [CrossRef] [Scilit]
  18. Ziccarelli, M.; Valore, C.; Muscolino, S.R.; Fioravante, V. Centrifuge tests on strip footings on sand with a weak layer. Geotech. Res. 2017, 4, 47–64. [Google Scholar] [CrossRef] [Scilit]
  19. Gulen, M.; Kilic, H. Effects of pipe deflection and arching on stress distribution and lateral earth pressure coefficient in buried flexible pipes. Appl. Sci. 2024, 14, 1667. [Google Scholar] [CrossRef] [Scilit]
  20. Forrester, A.I.J.; Keane, A.J. Recent advances in surrogate-based optimization. Prog. Aerosp. Sci. 2009, 45, 50–79. [Google Scholar] [CrossRef] [Scilit]
  21. Rasmussen, C.E.; Williams, C.K.I. Gaussian Processes for Machine Learning; MIT Press: Cambridge, MA, USA, 2006. [Google Scholar]
  22. Moayedi, H.; Hayati, S. Modelling and optimization of ultimate bearing capacity of strip footing near a slope by soft computing methods. Appl. Soft Comput. 2018, 66, 208–219. [Google Scholar] [CrossRef] [Scilit]
  23. Kounlavong, K.; Sadik, L.; Keawsawasvong, S.; Jamsawang, P. Novel hybrid XGBoost-based soft computing models for predicting penetration resistance of buried pipelines in cohesive soils. Ocean Eng. 2024, 311, 118948. [Google Scholar] [CrossRef] [Scilit]
  24. Yang, X.-S.; Gandomi, A.H.; Talatahari, S.; Alavi, A.H. (Eds.) Metaheuristics in Water, Geotechnical and Transport Engineering; Elsevier: London, UK, 2013. [Google Scholar]
  25. Kayabekir, A.E.; Arama, Z.A.; Bekdaş, G.; Nigdeli, S.M.; Geem, Z.W. Eco-friendly design of reinforced concrete retaining walls: Multi-objective optimization with harmony search applications. Sustainability 2020, 12, 6087. [Google Scholar] [CrossRef] [Scilit]
  26. Kashani, A.R.; Gandomi, A.H.; Azizi, K.; Camp, C.V. Multi-objective optimization of reinforced concrete cantilever retaining wall: A comparative study. Struct. Multidiscip. Optim. 2022, 65, 262. [Google Scholar] [CrossRef] [Scilit]
  27. Deb, K.; Pratap, A.; Agarwal, S.; Meyarivan, T. A fast and elitist multiobjective genetic algorithm: NSGA-II. IEEE Trans. Evol. Comput. 2002, 6, 182–197. [Google Scholar] [CrossRef] [Scilit]
  28. Deb, K.; Jain, H. An evolutionary many-objective optimization algorithm using reference-point-based nondominated sorting approach, Part I: Solving problems with box constraints. IEEE Trans. Evol. Comput. 2014, 18, 577–601. [Google Scholar] [CrossRef] [Scilit]
  29. Zitzler, E.; Laumanns, M.; Thiele, L. SPEA2: Improving the Strength Pareto Evolutionary Algorithm; TIK-Report 103; ETH Zurich: Zurich, Switzerland, 2001. [Google Scholar]
  30. Zhang, Q.; Li, H. MOEA/D: A multiobjective evolutionary algorithm based on decomposition. IEEE Trans. Evol. Comput. 2007, 11, 712–731. [Google Scholar] [CrossRef] [Scilit]
  31. Coello Coello, C.A.; Pulido, G.T.; Lechuga, M.S. Handling multiple objectives with particle swarm optimization. IEEE Trans. Evol. Comput. 2004, 8, 256–279. [Google Scholar] [CrossRef] [Scilit]
  32. Sörensen, K. Metaheuristics—The metaphor exposed. Int. Trans. Oper. Res. 2015, 22, 3–18. [Google Scholar] [CrossRef] [Scilit]
  33. Camacho-Villalón, C.L.; Dorigo, M.; Stützle, T. Exposing the grey wolf, moth-flame, whale, firefly, bat, and antlion algorithms: Six misleading optimization techniques inspired by bestial metaphors. Int. Trans. Oper. Res. 2023, 30, 2945–2971. [Google Scholar] [CrossRef] [Scilit]
  34. Wolpert, D.H.; Macready, W.G. No free lunch theorems for optimization. IEEE Trans. Evol. Comput. 1997, 1, 67–82. [Google Scholar] [CrossRef] [Scilit]
  35. Alnmr, A.; Alsirawan, R.; Hosamo, H.; Koch, E.; Tawalo, A.; Ismail, O.; Chetbani, Y. Hybrid machine learning and 3D numerical modeling-based multi-objective optimization of geosynthetic-reinforced pile-supported embankments. Front. Built Environ. 2026, 12, 1829950. [Google Scholar] [CrossRef] [Scilit]
  36. Naiboğlu, H. Şevli Zeminlerde Temel Yükü Etkisindeki Gömülü Boruların Zemin–Boru Etkileşiminin PIV Yöntemi ile Deneysel Olarak İncelenmesi [Experimental Investigation of Soil–Pipe Interaction of Buried Pipes Under Footing Load in Sloped Ground Using the PIV Method]. Ph.D. Thesis, Dicle University, Diyarbakır, Türkiye, 2026. (In Turkish) [Google Scholar]
  37. Naiboğlu, H.; Bildik, S.; Keskin, M.S. Experimental Investigation of Pipe–Soil Interaction in Slopes Using Particle Image Velocimetry (PIV). Appl. Sci. 2026, 16, 5328. [Google Scholar] [CrossRef] [Scilit]
  38. EN ISO 1452-2:2009; Plastics Piping Systems for Water Supply and for Buried and Above-Ground Drainage and Sewerage Under Pressure—Unplasticized Poly(vinyl chloride) (PVC-U)—Part 2: Pipes. European Committee for Standardization: Brussels, Belgium, 2009.
  39. Pedregosa, F.; Varoquaux, G.; Gramfort, A.; Michel, V.; Thirion, B.; Grisel, O.; Blondel, M.; Prettenhofer, P.; Weiss, R.; Dubourg, V.; et al. Scikit-learn: Machine learning in Python. J. Mach. Learn. Res. 2011, 12, 2825–2830. [Google Scholar]
  40. Bildik, S.; Laman, M. Experimental investigation of soil–structure–pipe interaction. KSCE J. Civ. Eng. 2019, 23, 3753–3763. [Google Scholar] [CrossRef] [Scilit]
  41. Kennedy, J.; Eberhart, R. Particle swarm optimization. In Proceedings of the ICNN’95—International Conference on Neural Networks, Perth, Australia, 27 November–1 December 1995; pp. 1942–1948. [Google Scholar]
  42. Storn, R.; Price, K. Differential evolution—A simple and efficient heuristic for global optimization over continuous spaces. J. Glob. Optim. 1997, 11, 341–359. [Google Scholar] [CrossRef] [Scilit]
  43. Raquel, C.R.; Naval, P.C. An effective use of crowding distance in multiobjective particle swarm optimization. In Proceedings of the 7th Annual Conference on Genetic and Evolutionary Computation (GECCO 2005), Washington, DC, USA, 25–29 June 2005; pp. 257–264. [Google Scholar] [CrossRef] [Scilit]
  44. Zitzler, E.; Thiele, L. Multiobjective evolutionary algorithms: A comparative case study and the strength Pareto approach. IEEE Trans. Evol. Comput. 1999, 3, 257–271. [Google Scholar] [CrossRef] [Scilit]
  45. Ishibuchi, H.; Masuda, H.; Tanigaki, Y.; Nojima, Y. Modified distance calculation in generational distance and inverted generational distance. In Evolutionary Multi-Criterion Optimization (EMO 2015); Lecture Notes in Computer Science; Springer: Cham, Switzerland, 2015; Volume 9019, pp. 110–125. [Google Scholar]
  46. Blank, J.; Deb, K. pymoo: Multi-objective optimization in Python. IEEE Access 2020, 8, 89497–89509. [Google Scholar] [CrossRef] [Scilit]
  47. ASTM D3034-21; Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings. ASTM International: West Conshohocken, PA, USA, 2021.
  48. Timoshenko, S. Theory of Elastic Stability; McGraw-Hill: New York, NY, USA, 1936. [Google Scholar]
  49. Lundberg, S.M.; Lee, S.-I. A unified approach to interpreting model predictions. Adv. Neural Inf. Process. Syst. 2017, 30, 4765–4774. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.