Abstract
This study examined the effects of post-rainfall hydrological conditions on the stability and seismic response of a valley-type ash storage dam in Liaoning, China. Laboratory tests and field water-level measurements were combined with sequential seepage, static stability, and dynamic analyses. The mean absolute error between the calculated and measured water levels at four monitoring points was 0.565 m. Dynamic triaxial tests revealed a decrease in the shear modulus ratio and an increase in the damping ratio with increasing effective shear strain. After receiving a uniform rainfall of 96 mm/d for 48 h, the dry beach length decreased from 100 to 50 m; for the same cumulative rainfall and duration, a late-peaking pattern reduced it to 30 m. The static factor of safety of the starter dam decreased by approximately 20%. At input amplitudes of 0.125 and 0.200 g, the relative acceleration and total displacement increased after rainfall. The largest local responses were observed near the crest and upper slope, and the starter dam had a lower factor of safety. These results indicate distinct spatial patterns of sliding stability and local seismic response for the modeled dam.
1. Introduction
Valley-type ash storage dams are formed through multiple stages of ash discharge, deposition, and raising, resulting in pronounced spatial differences in material zoning, density, and saturation. During their operation under sustained intense rainfall, rainwater infiltration combined with inadequate drainage can raise the phreatic line and reduce effective stress; additionally, if an earthquake follows, these dams may simultaneously experience reduced stability reserves, amplified dynamic deformation, and local liquefaction. Gao et al. identified the phreatic line, rainfall, earthquakes, and liquefaction as important controlling factors for the dam-break risk of tailings ponds during operation [1]. Through staged construction of a red-mud dam and post-closure seismic response analysis, Long et al. showed that the deposition height, weak zones, and earthquake intensity jointly governed stability evolution [2]. These studies indicate that safety assessments of depositional dams should start from the initial hydrological state and track changes in stability and deformation during the loading process.
Rainfall studies have mainly focused on links among infiltration, pore-pressure growth, and shear-strength degradation. Zhou et al. reported that increasing rainfall intensity and slope angle increased the peak water content, earth pressure, and pore-water pressure and aggravated the deformation of soil–rock mixture slopes [3]. Zhang et al. reported that low-permeability interlayers and void channels inside tailings dams caused local rises in the phreatic line and concentrated seepage, respectively [4]. With respect to unsaturated fly ash, Li et al. reported that the rainfall intensity affected the infiltration depth, saturated zone extent, and potential slip-surface location [5]. Through model tests, Shi et al. examined links among rainfall infiltration, pore-pressure growth, and effective-stress reduction [6]. Previous studies show that post-rainfall stability analysis should not replace surface infiltration with reservoir-level changes alone; field data should be used to calibrate the pre-rainfall seepage field, and the pore-pressure distribution at the end of rainfall should be considered the initial condition for subsequent calculations.
Recent studies have gradually shifted from single-result calculations toward monitoring or test verification, numerical simulation, and mechanism interpretation. Li et al. combined multisource monitoring of the rainfall, slope displacement, and anti-slide-pile response with numerical simulation, demonstrating that for the same cumulative rainfall, although short-duration intense rainfall caused a faster decrease in the factor of safety, it also resulted in faster recovery after rainfall stopped [7]. Wen et al. performed finite-element analysis of an anti-slide-pile-reinforced slope subjected to rainfall and reported that increased pore-water pressure and reduced soil strength were the main causes of increased displacement and that the pile position substantially changed the slope factor of safety and plastic-zone distribution [8]. These findings show that rainfall effects depend not only on cumulative rainfall but also on temporal distribution, verification scale, and weak structural locations.
Regarding model scale and rainfall-pattern effects, Wang et al. noted that the slope height, slope angle, and material similarity jointly affected the transition from small-scale models to prototype stability [9]. By comparing physical tests and numerical models, Zhang et al. analyzed uniform and intermittent rainfall and reported that rainfall patterns changed the pore-pressure response zone, lateral-displacement history, and attenuation process of the stability factor [10]. These studies indicate that the credibility of numerical conclusions depends not only on the calculation method but also on the verification target, scale relationship, and disclosure of boundary conditions and parameters. Existing studies have focused mainly on natural slopes, retaining structures, or homogeneous models and have not fully investigated the characteristics of hydraulically deposited ash storage dams, including multistage raising, material zoning, and subsequent earthquake loading after rainfall.
Under seismic loading, loose saturated fly ash may exhibit stiffness degradation, accumulated deformation, and liquefaction risk. Hu et al., Meng et al., and Liu et al. showed from the perspectives of ground-motion intensity measures, regional liquefaction probability, and compound intensity measures that the amplitude, spectrum, duration, and site conditions jointly affected the liquefaction response [11,12,13]. Zhao et al. used the PL-Finn model to analyze a liquefiable marine-dike foundation and the effect of gravel-pile reinforcement [14]. Recent studies of tailings dams and saturated fills have extended from seismic response to liquefaction triggering, residual strength, and post-liquefaction large deformation: Fan et al. identified zones exhibiting strong dynamic response and susceptibility to liquefaction in a phosphogypsum tailings dam [15], and Sordo et al. reported that even with the same peak acceleration, different ground motions could produce markedly different liquefaction depths and flow distances [16]. Verdugo emphasized the importance of undrained residual strength for static-liquefaction assessment of tailings [17]; furthermore, finite-element–material-point methods provide a new route for continuously simulating the process from liquefaction triggering to long-distance flow [18].
The present study compared the effect of a change in the hydrological state on the overall sliding stability of the starter dam and local dynamic responses of the crest and raised embankment. The slip-surface location, pore pressure, effective stress, and local response were examined under consistent analysis conditions.
Material parameters were determined through laboratory tests; the field water levels were used to verify the pre-rainfall seepage field, an hourly rainfall infiltration model was established, and the pore-pressure field at the end of rainfall was transferred to the static stability and three-dimensional dynamic models. Using consistent meshes, boundaries, material parameters, and output definitions, the factors of safety, relative accelerations, and displacement responses were compared for different hydrological states and ground-motion input amplitudes.
2. Engineering Background and Intense-Rainfall Scenarios
2.1. Project Overview and Seismic Environment
The study site is a valley-type ash storage facility serving a thermal power plant in Tieling, Liaoning Province, approximately 1.7 km from the plant. It operates by hydraulic ash disposal and uniform deposition in front of the dam. The starter dam was completed in 1992, with a maximum height of 33.0 m; after two stages of raised embankment construction, the current crest elevation is 122.5 m. Multistage deposition resulted in the formation of zones within the starter dam, raised embankments, and fly ash with different depositional states. Field monitoring reveals a locally high downstream phreatic line; therefore, the high post-rainfall phreatic line is considered the controlling initial state for stability and dynamic analyses.
The equivalent shear-wave velocity of soil overburden is no greater than 150 m/s, and its thickness is approximately 15–80 m; the site is classified as Class III. Dynamic analyses used input amplitudes of 0.125 g and 0.200 g. According to the project site parameters, a 0.125 g design earthquake has a response-spectrum characteristic period of 0.45 s, and a 0.200 g rare earthquake has a characteristic period of 0.50 s [19]. Both inputs are spectrum-matched within 0.1–25 Hz, with the matching error controlled below 5%.
2.2. Intense-Rainfall Scenarios and Initial Hydrological States
The pore-pressure field obtained from two-dimensional seepage calculation was imported into the three-dimensional dynamic model using a 2D–3D coordinate-mapping relationship. Following a treatment used in finite-element analyses of similar dams, linear interpolation between nodes was used within the section, and the section was extended along the dam axis under the assumption of uniform geometry and a hydraulic state subjected to plane strain. The pore-water-pressure and effective-stress contours for the same typical section were output before and after import; a peak relative difference of no more than 5% at the corresponding nodes was used as the spatial consistency criterion. Before dynamic calculation, self-weight equilibrium and pore-pressure equilibrium were achieved sequentially, with a nonlinear iteration residual tolerance of 0.01 [20,21].
Hourly input sequences were established for each rainfall case, recording the time, rainfall intensity (mm/d), cumulative rainfall (mm), duration, and rainfall pattern. The cumulative rainfall was calculated by integrating the rainfall intensity over time. Prescribed total heads at the lateral boundaries established the initial steady-state seepage field. During the transient rainfall stage, the model assumed no external water supply through these boundaries. The prescribed heads were therefore removed, and rainfall was applied as a uniformly distributed surface flux on the crest, dam slope, and starter-dam slope. Differences between the initial and post-rainfall states thus reflect the combined effects of the boundary change and rainfall infiltration.
3. Numerical Model and Analysis Methods
3.1. Laboratory Test Parameters
Laboratory tests on field-sampled fly ash included static triaxial, permeability, and dynamic triaxial tests. The strength, hydraulic, and dynamic parameters obtained from these tests were used in subsequent numerical analyses.
3.1.1. Static Triaxial Test Method
Fly-ash specimens were prepared by layered tamping at a controlled dry density of 1.015 g/cm3. After forming, each specimen was enclosed in a latex membrane and sealed in the pressure chamber. Carbon dioxide was introduced for 20 min, followed by addition of de-aired water at a volume 3–5 times the specimen volume until the degree of saturation exceeded 97%. The specimens were consolidated under confining pressures of 50, 100, and 150 kPa, after which consolidated-undrained and consolidated-drained shear tests were performed using the apparatus shown in Figure 1. The axial load, axial deformation, drainage volume, and pore-water pressure were recorded continuously. If a peak occurred before 15% axial strain, the peak was considered the failure strength; otherwise, the stress at 15% axial strain was used.
Figure 1.
Static triaxial shear test system.
3.1.2. Static Triaxial Test Results and Parameter Selection
The static triaxial tests yielded three sets of shear-strength parameters: under consolidated-drained (CD) conditions, the cohesion was 0.53 kPa and friction angle was 22.62°; meanwhile, under consolidated-undrained (CU) conditions, the cohesion was 8.12 kPa and friction angle was 29.63°. Furthermore, the effective-stress cohesion was 1.11 kPa, and the effective-stress friction angle was 34.97°. The two fitted lines in Figure 2a—c = 0.5333 kPa and φ = 22.62° and c′ = 8.117 kPa and φ′ = 29.63°—corresponded to the CD and CU test parameters, respectively; prime symbols denote figure annotations and do not indicate the effective-stress parameters used herein. In Figure 2b, c = 1.107 kPa and φ = 34.97° corresponded to the effective-stress envelope.
Figure 2.
Shear strength envelopes from static triaxial tests on fly ash.
Static stability calculations used the shear-strength parameters obtained from the consolidated-drained (CD) tests. The measured cohesion of 0.53 kPa and friction angle of 22.62° were rounded to 0.5 kPa and 22.6°, respectively, for the calculations. Pore-water pressure was included when calculating the effective normal stress along the slip surface.
3.1.3. Hydraulic and Dynamic Parameters
Hydraulic conductivity values were determined through laboratory falling-head and horizontal permeability tests; dynamic parameters were obtained from dynamic triaxial tests at a controlled dry density of 1.015 g/cm3. The sample counts for the horizontal and vertical hydraulic conductivities of the fine-grained fly ash were 45 and 46, with coefficients of variation of 0.547 and 0.409, respectively; the coarse-grained fly ash had two horizontal and 10 vertical samples, with a vertical coefficient of variation of 0.136. Table 1 lists the material parameters used in seepage and static analyses; Table 2 lists the maximum dynamic shear moduli by confining pressure and the corresponding fitted coefficients; and Figure 3 presents the shear modulus reduction and damping ratio curves. The same modulus reduction and damping ratio curves obtained from the dynamic triaxial tests were used for both fly ashes. For the transient seepage analysis, the fly-ash material was assigned a van Genuchten water-retention function and a Gardner conductivity function. Figure 3c shows the ratio of unsaturated to saturated hydraulic conductivity as a function of matric suction for the adopted Gardner parameters. When the prescribed rainfall flux exceeded the saturated hydraulic conductivity of the surface material, the model switched to a zero pressure-head boundary to limit infiltration.
Table 1.
Material parameters for seepage and static analyses.
Table 2.
Dynamic test parameters of fly ash.
Figure 3.
Fly-ash material properties: (a) shear modulus ratio; (b) damping ratio; (c) relative hydraulic conductivity adopted in the seepage model; (d) normalized maximum dynamic shear modulus versus normalized confining pressure with the power-law fit to the Table 2 data.
Dynamic triaxial tests were conducted using a geotechnical triaxial apparatus with bidirectional vibration under consolidated-undrained conditions. The confining pressures were 50, 100, and 150 kPa, and the specimen dry density was 1.015 g/cm3. Five replicate tests were conducted.
Both types of fly ash were assigned the same static strength parameters. The hydraulic conductivity was approximately 1–2 orders of magnitude higher for hydraulically deposited fly ash than that for Fly Ash 1. Over an effective dynamic shear strain range of 1.0 × 10−6 to 5.0 × 10−3, the mean shear modulus ratio decreased from 100.00% to 24.28% and damping ratio increased from 6.49% to 9.24%. A log–log least-squares fit to the Table 2 data gave a coefficient of 108.42 and an exponent of 1.2214 (Figure 3d). The reported relationship is , with pa = 100 kPa under isotropic consolidation.
3.2. Static Stability Analysis Method
To compare the overall stability reserves in the initial and post-rainfall hydrological states, the limit-equilibrium method of slices was used to search for potential circular slip surfaces. The post-rainfall pore-pressure field was mapped onto the slices along the slip surface; rainfall effects were represented by the reduction in effective normal stress caused by increased pore-water pressure, and the factor of safety was used to characterize the slope sliding resistance.
The ordinary method of slices (Fellenius or the Swedish circle method) [22] and simplified Bishop method were used for comparison. The ordinary method of slices assumes a circular slip surface and neglects interslice forces. The factor of safety is calculated from the overall moment equilibrium, as follows:
where Fs is the factor of safety; and are the effective cohesion and effective friction angle on the slip surface of slice i, respectively; li is the length of the slice base; Wi is the slice weight; αi is the inclination angle of the slice base; and ui is the pore-water pressure at the slice base.
The simplified Bishop method was proposed by Bishop [23]. It considers interslice normal forces and satisfies the overall moment equilibrium; the factor of safety is obtained iteratively, as follows:
Here, the correction factor is defined as ; the remaining symbols are the same as those in Equation (1). The project is a Class II facility. The initial case used the normal load combination, while the extreme-rainfall case referred to the limit state. Factor-of-safety limits were determined according to the Code for Design of Thermal Power Plants and Code for Design of Ash and Slag Storage Dams for Thermal Power Plants [24].
3.3. Equivalent-Linear Dynamic Response Analysis Method
An equivalent-linear viscoelastic constitutive model was used for the fly ash. At each iteration, the shear modulus and damping ratio were updated from the measured curves at the effective shear strain (Figure 3a,b). The equations of motion were integrated in the time domain using the Wilson–θ method. The governing equation and damping formulation are given below. The ground-motion processing and analysis cases are detailed in Section 3.5.
where [M], [C], and [K] are the mass, damping, and stiffness matrices, respectively; {u}, , and are the relative displacement, velocity, and acceleration vectors, respectively; {r} is the ground-motion input direction vector; and is the bedrock input acceleration.
Rayleigh damping was used, with the damping matrix expressed as a linear combination of the mass and stiffness matrices. Dynamic material behavior was represented by the maximum dynamic shear modulus, modulus reduction curve, and damping ratio curve.
Free-field boundaries were used on the side boundaries of the dynamic model, with fixed constraints and horizontal base acceleration applied at the bottom. The stress history from the dynamic analysis was used to determine the mobilized shear force along the selected slip surface. Available shear resistance was evaluated using the Mohr–Coulomb strength criterion. The ratio of total available shear resistance to total mobilized shear force at successive time steps defines the factor-of-safety time history. The minimum value over 0–20 s was reported, and 1.05—the dynamic factor-of-safety limit for a Class II ash storage facility—was used as the engineering reference value [20,25].
Stability analysis methods and dynamic model assumptions can affect results [26]. Furthermore, studies of saturated fills and foundations highlight the importance of defining output variables and verifying analysis methods [27,28,29,30,31]. Consistent inputs, meshes, material parameters, and output definitions were used to compare the cases.
3.4. Numerical Models, Boundary Conditions, and Monitoring Points
For two-dimensional seepage analysis, MIDAS GTS NX was used to construct a typical section having a length of 422 m and height of 60.7 m, with a mixed triangular–quadrilateral mesh containing 6708 nodes and 6480 elements (Figure 4). In steady-state calculation, the 100 m long initial dry beach was the head-application range; total heads of 60 m and 10 m were assigned at the left and right boundaries, respectively, and zero-pore-pressure drainage boundaries were set at the crest and dam surface. During the transient stage, the side total-head boundaries were deactivated, and uniform surface fluxes were applied to the crest, dam slope, and starter-dam slope. Future work will compare rainfall and no-rainfall cases under otherwise identical conditions to distinguish the effect of infiltration from that of the boundary change. Additionally, free-field side boundaries and a fixed bottom constraint were used in the three-dimensional dynamic model (Figure 5).
Figure 4.
Dam seepage model and boundary conditions.
Figure 5.
Dynamic analysis meshes before and after intense rainfall.
After determining the seepage parameters from laboratory tests, four field water-level points not used for parameter calibration were selected for independent verification of the pre-rainfall seepage field. The calculated/measured values were 15.24/16.11, 17.12/17.42, 19.82/20.71, and 22.44/22.64 m. The mean signed error was −0.565 m, mean absolute error was 0.565 m, root-mean-square error was 0.648 m, and maximum absolute error was 0.89 m. The inverse-analysis approach required for using field water levels to verify the seepage field is described in Ref. [32].
The two-dimensional and three-dimensional models used consistent material zoning; the main dynamic model parameters are listed in Table 3. For both fly-ash materials, Table 3 lists the model coefficient as 108.42. A modulus exponent of 1.2214 was used for both fly-ash materials (Table 3). The laboratory fit shown in Figure 3d uses a reference pressure of 100 kPa. The Poisson ratios of the compacted rockfill in the starter dam and the highly weathered granite in the foundation were both set to 0.45 with reference to project engineering documentation and the relevant literature. For comparison, wave velocities measured below the water table in sand, gravel, and decomposed granite fill gave Poisson ratios above 0.44 [33]. Laboratory measurements on sand show that the dynamic Poisson ratio rises sharply as full saturation is approached [34]. A rock-mass Poisson ratio of 0.45 has also been used in continuum modeling of the long-term evolution of a jointed gneiss slope [35]. A Poisson ratio of 0.48 was used for saturated fly ash to reflect near-incompressibility. A controlled specimen dry density of 1.015 g/cm3 was used only for laboratory preparation and not as a substitute for the saturated mass density in the numerical model. The pre- and post-rainfall dynamic cases used the identical geometry, mesh, material parameters, boundary conditions, and solver settings, updating only the pore-pressure field obtained from seepage analysis. 2D–3D coordinate conversion used linear nodal interpolation and extension along the dam axis under a uniform plane-strain assumption; consistency was checked using the pore pressure and effective stress at corresponding nodes in a typical section, with the peak relative difference controlled below 5% [20,21]. Previous studies have shown that material heterogeneity, geometric evolution, and analysis dimensionality affect stability assessment [36,37,38,39,40,41,42].
Table 3.
Main material parameters for dynamic analysis.
The same material zoning and boundary conditions were used for all dynamic cases; only the initial pore-pressure field and ground-motion input differed.
3.5. Ground-Motion Inputs and Analysis Cases
We selected the horizontal El Centro accelerogram because of its widespread and long-standing use in earthquake engineering. Its digitized time history is publicly available, facilitating verification and repeated application across analysis cases. Using the same reference record maintains a consistent input waveform for comparing dynamic responses under different conditions. The record has pronounced positive and negative acceleration peaks early in the time history, followed by generally smaller amplitudes. We therefore used this record to compare the dam responses before and after rainfall at each earthquake level. We used the first 20 s of the approximately 53 s record, sampled at 0.02 s intervals. We matched this segment to the target response spectra adopted for the Tieling site at the design earthquake level (0.125 g, characteristic period 0.45 s) and the rare-earthquake level (0.200 g, characteristic period 0.50 s). At each level, we applied the same matched motion to the initial and post-rainfall states to compare the dam responses (cases C1–C4 in Table 4). For both inputs, the spectrum-matching error was controlled below 5% within 0.1–25 Hz. The acceleration index is the peak absolute value of the relative acceleration time history over 0–20 s; the maximum total displacement is the maximum value of the total displacement field of the dam over the same interval. The ground-motion history and monitoring point layout are shown in Section 5.1.
Table 4.
Dynamic analysis cases.
The pre-rainfall seepage field was independently verified using the four field water-level points not involved in parameter calibration; additionally, joint observations of saturation, pore pressure, and deformation were used to examine the transient response [43]. Section 5.4 draws on a separate project assessment of fly-ash liquefaction to interpret the stability results.
3.6. Model Verification and Scope
The four field water-level measurements not used for parameter calibration were used to verify the pre-rainfall seepage field. The four dynamic cases used consistent geometry, meshes, materials, boundaries, pore-pressure mapping, and output procedures. The time discretization, calibration, and convergence settings are described in Section 3.3, Section 3.4 and Section 3.5.
4. Seepage and Static Stability After Intense Rainfall
4.1. Seepage Response
The calculated/measured water levels at the four monitoring points were 15.24/16.11, 17.12/17.42, 19.82/20.71, and 22.44/22.64 m (Figure 6). The corresponding errors were −0.87, −0.30, −0.89, and −0.20 m, respectively. The mean signed error was −0.565 m, mean absolute error was 0.565 m, and root-mean-square error was 0.648 m. Figure 7 compares the pore-water-pressure distributions under different rainfall intensities.
Figure 6.
Measured and calculated phreatic lines under no-rainfall conditions.
Figure 7.
Pore-water-pressure distributions in the dam for different rainfall intensities.
Transient seepage calculations applied uniform surface fluxes to the crest, dam slope, and starter-dam slope and deactivated the side total-head boundaries. The rainfall intensities were 24, 48, and 96 mm/d, and the durations were 12, 24, and 48 h. For a uniform pattern, the cumulative rainfall was calculated as the intensity multiplied by the duration in days; for example, 96 mm/d for 48 h corresponds to 192 mm. The patterns included early-peaking, uniform, late-peaking, and stepwise types; the nonuniform patterns were implemented through hourly input sequences for the same cumulative rainfall and duration. The zero-pore-pressure contour was considered the phreatic line, and the dry beach length was extracted from its exit point.
After uniform rainfall of 96 mm/d for 48 h, the dry beach length decreased from 100 to 50 m. For the same cumulative rainfall and duration, the late-peaking pattern decreased it to 30 m (Figure 8).
Figure 8.
Phreatic lines and dry beach lengths under different rainfall patterns. Numbers 1–7 identify the borehole locations used to determine the depth to the phreatic line.
4.2. Static Stability
Figure 9, Figure 10, Figure 11 and Figure 12 compare the potential slip surfaces and factors of safety. For the starter dam, the ordinary method of slices revealed a decrease from 1.910 to 1.519 (20.5%) after rainfall, and the simplified Bishop method yielded a decrease from 1.946 to 1.540 (20.9%). Thus, the two methods showed similar reductions.
Figure 9.
Simplified Bishop results for the initial hydrological state.
Figure 10.
Ordinary method of slices results for the initial state.
Figure 11.
Simplified Bishop results after intense rainfall.
Figure 12.
Ordinary method of slices results after intense rainfall.
According to the Code for Design of Thermal Power Plants and Code for Design of Ash and Slag Storage Dams for Thermal Power Plants, the ash storage dam is designed as a Class II facility [24]. The initial case was assessed using a normal load combination, and the extreme-rainfall case was assessed using the limit state. Under the normal load combination, the factor-of-safety limits for the simplified Bishop and ordinary methods of slices were 1.25 and 1.15, respectively; under the limit state, the corresponding limits were 1.05 and 1.00, respectively. The results for all cases are presented in Figure 9, Figure 10, Figure 11 and Figure 12 and in the values reported above.
5. Seismic Response and Dynamic Stability Analysis
5.1. Acceleration Response
Figure 13 shows the input ground motion and monitoring locations. Figure 14 and Figure 15 compare the relative acceleration time histories at input amplitudes of 0.125 g and 0.200 g, respectively. The absolute peak values were evaluated over 0–20 s. At 0.125 g, the response ratios at points A, B, and C were 1.512, 1.600, and 1.760 in the initial state and 2.120, 2.336, and 2.416 after rainfall, respectively. At 0.200 g, the corresponding ratios were 1.45, 1.55, and 1.70 initially and 2.05, 2.25, and 2.30 after rainfall, respectively.
Figure 13.
Input ground motion and acceleration monitoring locations.
Figure 14.
Relative acceleration time histories at 0.125 g (C1 and C2).
Figure 15.
Relative acceleration time histories at 0.200 g (C3 and C4).
At 0.125 g, the relative acceleration increased after rainfall at all three monitoring points. The largest response was observed at the crest point C (Figure 14).
All 0.200 g cases showed the same spatial pattern: the largest relative acceleration occurred at the crest, and the responses increased after rainfall (Figure 15).
5.2. Displacement Response
Figure 16 and Table 5 summarize the maximum total displacement over 0–20 s. At 0.125 g, the displacement increased from 29.1 cm in the initial state to 41.0 cm after rainfall (40.9%). At 0.200 g, it increased from approximately 56 to 63 cm (12.5%).
Figure 16.
Maximum total displacement contours at 0.125 g and 0.200 g.
Table 5.
Calculated displacement and dynamic factor-of-safety results.
These values represent the peak total displacement during shaking. The same 0–20 s window and case definitions were used for the displacement, acceleration, and dynamic factors of safety.
The largest displacements occurred at the crest and upper slope and decreased toward the foundation. This spatial pattern was similar to that of relative acceleration.
5.3. Dynamic Stability
Figure 17 and Figure 18 show the time histories of the dynamic factor of safety at 0.125 g and 0.200 g, respectively. Minimum values were evaluated over the first 20 s, with a sampling interval of 0.02 s.
Figure 17.
Dynamic factor-of-safety time histories at 0.125 g.
Figure 18.
Dynamic factor-of-safety time histories at 0.200 g.
At 0.125 g, the minimum factors of safety of the starter dam and raised embankment decreased from 1.58 and approximately 3.54 to 1.22 and approximately 3.26, respectively, after rainfall (Table 5). At 0.200 g, the values decreased from approximately 1.37 and 3.10 to 1.07 and 2.85, respectively.
At 0.125 g, the minimum dynamic factor of safety was lower after rainfall for both sliding masses and remained lower for the starter dam than that for the raised embankment (Figure 17).
Under the project design earthquake (0.125 g), the starter dam satisfied the sliding stability criterion even after extreme rainfall: its minimum factor of safety was 1.22 against the adopted limit of 1.05. To examine the remaining safety reserve under more severe loading, we also evaluated the extreme-rainfall state under the rare earthquake (0.200 g). In this additional scenario, the minimum factor was 1.07, leaving a margin of 0.02 above the limit (Figure 17 and Figure 18).
5.4. Comparison with Previous Studies
In the modeled cases, rainfall raised the phreatic line and increased the seismic acceleration and displacement. The starter dam had a lower factor of safety, and the largest local responses occurred near the crest and upper slope.
Hu et al. investigated liquefaction using a test-calibrated effective-stress model and multiple ground motions [11]. Meanwhile, the present analysis compared the sliding stability and local dynamic response for specified hydrological states and ground-motion inputs. A separate liquefaction assessment for this project identified a zone below the phreatic surface in the upstream part of the deposit, away from the dam, under design-level shaking. At the initial water level under the rare earthquake (0.200 g), the predicted liquefaction zone remained concentrated at the upstream end of the ash deposit. Under the combined extreme-rainfall and rare-earthquake scenario, the predicted liquefaction zone extended into the fly ash beneath the raised embankment. Excess pore-water pressure generated during shaking could reduce the effective stress and shear resistance of the supporting ash, adding a local foundation concern to the limited sliding safety margin calculated for the starter dam.
5.5. Engineering Implications
The results reveal the crest displacement and pore-water pressure of the starter dam and downstream drainage as relevant monitoring parameters during and after intense rainfall.
Model parameters, hourly rainfall inputs, pore-pressure mapping, ground-motion inputs, and response extraction were consistently documented across the cases.
The findings apply to the specified geometry, materials, hydrological states, and input motions.
6. Conclusions
The present analyses of the valley-type ash storage dam yield the following conclusions.
- (1)
- The dynamic shear modulus ratio decreased and damping ratio increased with increasing effective shear strain. Static stability calculations used a cohesion of 0.5 kPa and a friction angle of 22.6°, obtained from CD tests.
- (2)
- The calculated pre-rainfall water levels were lower than the measured values at all four monitoring points. The mean and maximum absolute errors were 0.565 and 0.89 m, respectively.
- (3)
- Uniform rainfall of 96 mm/d for 48 h reduced the dry beach length from 100 to 50 m; a late-peaking pattern with the same cumulative rainfall and duration reduced it to 30 m. The static factor of safety of the starter dam decreased by approximately 20%.
- (4)
- Rainfall increased the relative acceleration and total displacement near the crest and upper slope. The maximum displacement increased by 40.9% at 0.125 g and by 12.5% at 0.200 g. The starter dam met the sliding stability criterion under the project design earthquake, with a minimum factor of safety of 1.22 even after extreme rainfall. In the additional extreme scenario used to examine the remaining safety reserve, the minimum factor fell to 1.07.
These findings are specific to the modeled dam and investigated rainfall and ground-motion inputs.
Author Contributions
Conceptualization, J.Z. and H.X.; Methodology, Y.Z., J.Z. and T.D.; Software, Y.Z.; Validation, Y.Z.; Formal analysis, Y.Z.; Investigation, Y.Z.; Resources, Y.Z.; Data curation, Y.Z.; Writing—original draft, Y.Z.; Writing—review and editing, Y.Z., J.Z., T.D. and H.X.; Visualization, Y.Z.; Project administration, J.Z. and H.X.; Funding acquisition, J.Z. and H.X. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
Key laboratory test results, field water-level measurements used for model validation, and numerical simulation results are reported in the article. Further inquiries about the underlying data may be directed to the corresponding author.
Conflicts of Interest
The authors declare no conflict of interest.
References
- Gao, T.; Qin, Z.; Yang, R.; Li, Q.; Geng, C.; Zhang, J.; Chen, Z. Study on risk assessment and risk prevention of dam failure during the operation period of tailings pond. Buildings 2025, 15, 2833. [Google Scholar] [CrossRef] [Scilit]
- Long, S.; Ma, S.; An, P. Study on the stability evolution mechanism of a red mud dam during construction and safety under earthquake during operation. Buildings 2024, 14, 3677. [Google Scholar] [CrossRef] [Scilit]
- Zhou, F.Y.; Wu, H.B.; Qiang, Y.; Liu, G.; Zhang, Z.; Zhang, Y.; Chen, N. Investigating the coupling effects of rainfall intensity and slope inclination on soil-rock mixture slope stability and failure modes. PLoS ONE 2025, 20, e0314752. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, H.; Li, Q.M.; Wang, J.C.; Fu, B. The impact of lenses on the seepage failure of tailings dam. PLoS ONE 2024, 19, e0305425. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, R.; Wang, B.; Xu, C. Permeability characteristics of unsaturated fly ash and its effect on ash storage dam stability. Hydrogeol. Eng. Geol. 2025, 52, 108–118. (In Chinese) [Google Scholar] [CrossRef]
- Shi, G.; Tao, Z.; Zhao, F.; Dong, J.; Yang, X.; Xu, Z.; Hu, X. Model test of mechanical response of negative Poisson’s ratio anchor cable in rainfall-induced landslides. Buildings 2025, 15, 1745. [Google Scholar] [CrossRef] [Scilit]
- Li, P.J.; Li, Q.; Feng, Q.S.; Huang, Z.; Gan, X.; Ding, H.; Xu, C. Multi-source monitoring and numerical simulation deformation on highway steep slopes under rainfall effects. Buildings 2024, 14, 3473. [Google Scholar] [CrossRef] [Scilit]
- Wen, Z.Y.; Xu, W.Y.; Yuan, B.X.; Zhang, L.; Liang, Z. Numerical analysis of anti-slide pile reinforcement for slope stability under rainfall conditions. Buildings 2025, 15, 638. [Google Scholar] [CrossRef] [Scilit]
- Wang, M.H.; Wang, X.L.; Fu, G.Q.; Zhou, M.; Chen, J. A numerical study on the utilization of small-scale model testing for slope stability analysis. Buildings 2025, 15, 1015. [Google Scholar] [CrossRef] [Scilit]
- Zhang, L.J.; Tian, X.K.; Jiang, W.W.; Lin, C.; Fang, M.; Shang, W.; Zhang, Y.; Liu, F. Study on the influence of rainfall patterns on the stability of reinforced soil gabion retaining walls. Buildings 2026, 16, 1003. [Google Scholar] [CrossRef] [Scilit]
- Hu, B.; Ji, W.; Zhao, Y.; Qiu, S.; Zhu, Z. Assessment of seismic intensity measures on liquefaction response: A case study of Yinchuan sandy soil. Buildings 2025, 15, 3803. [Google Scholar] [CrossRef] [Scilit]
- Meng, J.Y.; Shan, B.H.; Lu, D.G. Rapid regional liquefaction probability assessment based on transfer learning. Buildings 2025, 15, 3243. [Google Scholar] [CrossRef] [Scilit]
- Liu, T.; Lu, D. Evaluation of Ground Motion Damage Potential with Consideration of Compound Intensity Measures Using Principal Component Analysis and Canonical Correlation Analysis. Buildings 2024, 14, 1309. [Google Scholar] [CrossRef] [Scilit]
- Zhao, J.; Lin, Y.H.; Fan, Y.J.; Yu, X. Liquefaction analysis of marine diversion dike foundation and gravel pile reinforcement treatment based on the PL-Finn model. PLoS ONE 2025, 20, e0330325. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Fan, B.; Cheng, Z.; Wang, T.; Wang, S. Dynamic response characteristics and liquefaction analysis of a phosphogypsum tailings dam. Int. J. Geomech. 2025, 25, 05024012. [Google Scholar] [CrossRef] [Scilit]
- Sordo, B.; Rathje, E.; Kumar, K. Runout of liquefaction-induced tailings dam failure: Influence of earthquake motions and residual strength. Soil Dyn. Earthq. Eng. 2025, 194, 109371. [Google Scholar] [CrossRef] [Scilit]
- Verdugo, R. Static liquefaction in the context of steady state/critical state and its application in the stability of tailings dams. Soil Dyn. Earthq. Eng. 2024, 176, 108270. [Google Scholar] [CrossRef] [Scilit]
- Sordo, B.; Rathje, E.; Kumar, K. Hybrid finite-element and material point method for modeling liquefaction-induced tailings dam failures. J. Geotech. Geoenvironmental Eng. 2025, 151, 04025086. [Google Scholar] [CrossRef] [Scilit]
- China Earthquake Administration. Seismic Ground-Motion Parameter Zoning Map of China: GB 18306—2015; Standards Press of China: Beijing, China, 2015. (In Chinese) [Google Scholar]
- MIDAS, I.T. GTS NX User Manual: Analysis and Slope Stability Modules; MIDAS IT: Seongnam, Republic of Korea, 2020. [Google Scholar]
- COMSOL AB. Slope Stability in an Embankment Dam: Geomechanics Module Application Library; COMSOL AB: Stockholm, Switzerland, 2025. [Google Scholar]
- Fellenius, W. Erdstatische Berechnungen mit Reibung und Kohäsion (Adhäsion) und unter Annahme kreiszylindrischer Gleitflächen; W. Ernst & Sohn: Berlin, Germany, 1927. [Google Scholar]
- Bishop, A.W. The use of the slip circle in the stability analysis of slopes. Géotechnique 1955, 5, 7–17. [Google Scholar] [CrossRef] [Scilit]
- China Electric Power Planning and Engineering Institute. Code for Design of Ash and Slag Storage Dams for Thermal Power Plants: DL/T 5045—2006; China Electric Power Press: Beijing, China, 2006. (In Chinese) [Google Scholar]
- Griffiths, D.V.; Lane, P.A. Slope stability analysis by finite elements. Géotechnique 1999, 49, 387–403. [Google Scholar] [CrossRef] [Scilit]
- Hosseini, S.; Astaraki, F.; Imam, S.M.R.; Chalabii, J.; Rad, M.M. Investigation of shear strength reduction method in slope stability of reinforced slopes by anchor and nail. Buildings 2024, 14, 432. [Google Scholar] [CrossRef] [Scilit]
- Chen, B.; Ye, Y.; Wang, D.; Li, Y.; Xiong, J.; Qu, C. Seismic response characteristics and liquefaction risk of artificial island with saturated hydraulic fill coral sand. Ocean Eng. 2025, 317, 120025. [Google Scholar] [CrossRef] [Scilit]
- Deng, W.; Wang, C.; Ou, Q.; Ding, X.; Luan, L.; Xu, Y.; Feng, H. Seismic response of pile-supported embankment in unequal thickness liquefiable soil with V-shape underlying stratum. Soil Dyn. Earthq. Eng. 2024, 182, 108757. [Google Scholar] [CrossRef] [Scilit]
- Li, Z.; Zou, H.; Jian, S.; Li, Z.; Lin, H.; Yu, X.; Li, M. Study on the effect of liquefiable overburden foundations of rockfill dams based on a pore pressure model. Water 2024, 16, 2649. [Google Scholar] [CrossRef] [Scilit]
- Zhang, X.L.; Lan, H.; Zhao, X.H.; Xu, C.S.; Jia, K.M. Study on Different Reinforcement Methods of Inclined Liquefiable Site. Soil Dyn. Earthq. Eng. 2024, 176, 108342. [Google Scholar] [CrossRef] [Scilit]
- El Sherbiny, E.M.; Wang, J.T. Stone Column Strategies for Mitigating Liquefaction-Induced Uplift of Tunnels. Soil Dyn. Earthq. Eng. 2024, 187, 108961. [Google Scholar] [CrossRef] [Scilit]
- Zhang, F.; Dong, L.; Wang, H.; Zhong, K.; Zhang, P.; Jiang, J. Inverse analysis of strata in seepage field based on regularization method and geostatistics theory. Buildings 2024, 14, 946. [Google Scholar] [CrossRef] [Scilit]
- Kokusho, T. Correlation of pore-pressure B-value with P-wave velocity and Poisson’s ratio for imperfectly saturated sand or gravel. Soils Found. 2000, 40, 95–102. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kumar, J.; Madhusudhan, B.N. Dynamic properties of sand from dry to fully saturated states. Géotechnique 2012, 62, 45–54. [Google Scholar] [CrossRef] [Scilit]
- Riva, F.; Agliardi, F.; Amitrano, D.; Crosta, G.B. Damage-based time-dependent modeling of paraglacial to postglacial progressive failure of large rock slopes. J. Geophys. Res. Earth Surf. 2018, 123, 124–141. [Google Scholar] [CrossRef] [Scilit]
- Du, C.; Tao, H.; Yi, F. Seepage stability analysis of geogrid reinforced tailings dam. Sci. Rep. 2024, 14, 1814. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jin, S.; Geng, C. Numerical calculation of seepage field and stability analysis of dam body of closed tailings pond. Appl. Math. Nonlinear Sci. 2024, 9, 20240005. [Google Scholar] [CrossRef] [Scilit]
- Khanal, M.; Shi, J.; Qu, Q. Effect of stepwise increase in tailings deposition on tailings dam stability. Minerals 2025, 15, 346. [Google Scholar] [CrossRef] [Scilit]
- Chen, D.; Yue, X.; Zhang, H.; Shen, Z. Seepage analyses of tailings dam using 3D saturated-unsaturated and equivalent seepage method. ce/papers 2025, 8, 409–417. [Google Scholar] [CrossRef] [Scilit]
- Su, Y. Study on the seepage field of an ash storage dam at a power plant. Civ. Eng. 2024, 13, 2190–2198. (In Chinese) [Google Scholar] [CrossRef]
- Qin, P.F. Stability analysis of dam grouting reinforcement based on FLAC3D. PLoS ONE 2026, 21, e0342938. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- National Energy Administration. Code for Design of Dry Ash Storage Facilities for Thermal Power Plants: DL/T 5488—2024; China Planning Press: Beijing, China, 2024. (In Chinese) [Google Scholar]
- Peng, Y.; Yang, Y.; Zhang, S.; Hu, J.; Ren, J.; Xue, X. Seismic response of liquefiable marine sand treated by microbially induced desaturation through shaking table tests. Buildings 2026, 16, 1463. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.