Abstract
This study presents the modelling and analysis of neutron spectra in the European demonstration fusion power plant (EU DEMO) helium-cooled pebble bed (HCPB) divertor using OpenMC. The OpenMC model was developed by converting an existing MCNP geometry model. The converted model was supplemented with material definitions, FENDL–3.2b and ENDF/B–VIII.0 nuclear data libraries, tally settings, variance reduction parameters, and a deuterium–tritium plasma neutron source. Neutron spectra were calculated for ten divertor components containing tungsten, a homogenized W-CuCrZr-H2O mixture, EUROFER, INCONEL alloy, titanium alloy and water. Statistical precision was assessed using median and flux-weighted relative uncertainties, both of which were below 10% in nine of the ten OpenMC regions. The OpenMC spectra were compared with previously calculated MCNP reference spectra. Energy groups with positive MCNP flux and an OpenMC/MCNP ratio not exceeding 20 were retained. Reference-normalized absolute spectral differences ranged from 8.36% to 17.65% in nine regions and reached 58.16% in the small water pipe. Unfiltered results are reported in the appendices. The analysis quantifies component-specific spectral differences and identifies the regions in which statistical precision limits the interpretation of individual energy groups.
Keywords:
OpenMC; MCNP; EU DEMO; HCPB divertor; neutron spectrum; Monte Carlo method; neutron transport 1. Introduction
Neutron transport calculations provide essential input for evaluating nuclear heating, material damage and activation in the EU DEMO divertor. Neutrons produced by deuterium–tritium (D-T) fusion undergo scattering and absorption in the surrounding components, resulting in neutron energy distributions that depend on material composition and geometrical position [1]. Energy-resolved neutron spectra are therefore required because similar integrated neutron fluxes do not necessarily produce equivalent material responses.
The divertor removes exhaust power and helium ash from the plasma, while its components must withstand both intense thermal loads and neutron irradiation [1]. You et al. [2] reviewed the engineering requirements and technological development of the EU DEMO divertor, highlighting heat removal and the structural integrity of irradiated materials as major challenges. Noce et al. [3] performed neutronics and activation analyses of tungsten used in the EU DEMO divertor targets, comparing the effects of the HCPB and WCLL breeding blanket configurations. These studies provide relevant context for examining neutron spectra in individual divertor materials and structural regions.
Monte Carlo transport codes calculate neutron distributions by statistically sampling particle trajectories and interactions [1]. Available tools differ in their scope and modelling workflows. MCNP is a general-purpose Monte Carlo particle transport code used in reactor neutronics, radiation shielding and dosimetry calculations [1]. Other transport codes offer related capabilities: TRIPOLI-4 supports continuous-energy neutron and photon transport [4], while Serpent 2 combines neutron and photon transport with depletion calculations for reactor physics and fusion neutronics applications [5]. FLUKA and Geant4 have a broader particle transport scope, supporting applications in radiation protection, dosimetry and high-energy physics [6,7]. Within this range of tools, OpenMC is an open-source code supporting detailed three-dimensional neutron transport calculations [8,9,10]. Its Python (version 3.13.14) interface enables programmatic model definition, simulation control and automated processing of results [9]. These capabilities make it useful for workflows involving repeated model modifications and comparisons across multiple material regions.
The application of OpenMC to fusion neutronics has been examined through experimental benchmarks and comparisons with other transport codes. The FNG-streaming benchmark study compared OpenMC calculations with experimental measurements and reference MCNP results, and evaluated the use of weight windows for neutron shielding calculations [10]. For reactor-scale models, Afanasenko et al. [11] investigated the translation and synchronization of MCNP and OpenMC models for ITER neutronics. Park [12] presented benchmark calculations for EU DEMO and a volumetric neutron source facility, identifying issues involving source conversion, lattice geometry, boundary conditions and weight window performance. These studies motivate component-specific comparisons rather than an assumption that transferring a model automatically preserves its results. For detailed divertor spectra, agreement must be assessed both across individual energy groups and over the complete energy range, with statistical uncertainty evaluated separately from differences between codes.
This work investigates neutron energy spectra in ten divertor cells of the EU DEMO HCPB configuration using OpenMC. An existing MCNP model was adapted to OpenMC, and the calculated spectra were compared with previously obtained MCNP reference results documented by Breidokaitė and Stankūnas [1,13]. The objectives were to examine spectral characteristics in different materials and geometrical regions, quantify spectral and integrated-flux differences and evaluate these differences in relation to Monte Carlo sampling uncertainties.
2. Materials and Methods
This section describes the methodology used to calculate neutron transport and spectra in the EU DEMO divertor model with the HCPB breeding blanket configuration using OpenMC. The OpenMC model includes the divertor geometry, material compositions, plasma neutron source, nuclear data libraries, and variance reduction parameters.
2.1. Neutron Transport Calculation and Data Analysis
OpenMC uses the Monte Carlo method to solve the neutron transport equation:
where Ω is the neutron flight-direction unit vector, ψ is the angular neutron flux, is the total macroscopic cross section, and Q represents the neutron source and scattering terms [14].
The distance travelled by a neutron between consecutive interactions was sampled from an exponential distribution:
where l is the neutron free-path length and is a uniformly distributed random number in the interval (0;1) [1,15]. For materials containing several nuclides, the total macroscopic cross-section was calculated as:
where Ni and σt,i are the number density and microscopic cross section of nuclide i, respectively [1]. Particle histories ended upon absorption or escape from the model [15].
Neutron spectra were scored using the track-length estimator with cell and incident-energy filters [16]. The raw OpenMC flux tally TO,i represents the sum of neutron track lengths within the cell and energy group i, weighted by the corresponding statistical particle weights and normalized per source history. This tally has not yet been divided by the physical cell volume; division by V in Equation (4) converts it to a cell-averaged quantity. The physical cell-averaged, group-integrated neutron flux was calculated as follows:
where S = 7.093538 × 1020 n/s is the full-device neutron emission rate [1], and V is the physical cell volume adopted from the MCNP model in cm3. The factor 1/32 accounts for the 11.25° model sector. The resulting neutron flux was expressed in n/(cm2∙s). Results were extracted from the OpenMC statepoint and summary files and processed using Python.
As a numerical check, the exported raw OpenMC total-flux tally for cell 7090 was 1.940430 × 10−6 cm per source history. Using a cell volume of 0.662744 cm3 and a full-device neutron emission rate of 7.093538 × 1020 n/s, the normalization in Equation (4) gives
Applying the same normalization factor to the exported tally standard error of 4.308280 × 10−8 cm per source history gives approximately 1.441023 × 1012 n/cm2s. These values agree with those reported in Appendix B, Table A3 to the displayed precision.
The reference MCNP spectra were obtained using an F4 track-length tally. The SD4 card set the tally volume divisors to unity, while the initial source-particle weight already included the sector factor of 0.03125. Consequently, the corresponding MCNP results were normalized as:
The same multiplicative normalization factors were applied to the respective tally standard errors. As a numerical check, the MCNP F4 tally (tally 24) total for cell 7090 was 3.89409 ×1013, which already includes the source-strength multiplier. Using V = 0.662744 cm3 gives:
the corresponding value in Appendix B, Table A3, obtained from the dataset used in the analysis, is 5.87 × 1013 n/(cm2s).
The statistical precision of the calculated spectra was summarized using the median and flux-weighted relative statistical uncertainties. The arithmetic mean was retained as a supplementary descriptive indicator because it is sensitive to poorly sampled, low-flux energy groups. The flux-weighted relative uncertainty was defined as follows:
where Rfw is the flux-weighted relative statistical uncertainty, Φi is the group-integrated neutron flux and ui is its relative statistical uncertainty in energy group i. The sums include only energy groups with positive flux and finite relative uncertainty, with N denoting the number of included groups. The same selection applies to all group-wise uncertainty summaries and is performed separately for OpenMC and MCNP. Groups with zero flux are excluded because their relative uncertainty is undefined. This descriptive measure reduces the influence of large relative uncertainties in groups with negligible neutron flux. The integrated OpenMC flux and its standard error were obtained directly from a separate cell flux tally without an energy filter and normalized by the same factor as in Equation (4). A relative uncertainty of 10% was used as a descriptive reference for consistency with the reference MCNP study [1].
Low-energy regions may exhibit large statistical uncertainties due to insufficient particle sampling. To improve sampling efficiency, weight windows assign an acceptable particle weight range to each spatial and energy region. Particles above the upper limit are split, whereas those below the lower limit undergo Russian rouletting [17]. In this study, weight windows were generated using the MAGIC algorithm [18]. A preliminary simulation was used to produce a weight window map, which was subsequently applied when calculating neutron spectra and spatial flux distributions. The neutron weight-window meshes used cylindrical coordinates, with 68 radial, four toroidal, and 104 axial intervals, giving 28,288 spatial bins per mesh. The toroidal grid covered the modelled sector from 0° to 11.25° in four equal intervals. Four energy groups were defined by boundaries at 0 eV, 100 eV, 100 keV, 1 MeV, and 20 MeV. This four-group structure was used for variance reduction and was distinct from the CCFE-709 structure used to score the neutron spectra. The weight-window settings included max_split = 10, survival_ratio = 3.0, max_lower_bound_ratio = 1.0, and weight_cutoff = 10−38.
The spatial distribution of the energy-integrated neutron flux was calculated using a track-length flux tally on a regular Cartesian mesh of 60 × 30 × 20 voxels, covering x = 510 to 940 cm, y = −50 to 200 cm, and z = −776 to −544 cm. The voxel dimensions were approximately 7.167 × 8.333 × 11.600 cm. The raw mesh scores and their standard errors were normalized using the same source-strength and sector factors as in Equation (4), with the voxel volume replacing the cell volume. The maps show an x–z slice centred at y = 70.833 cm.
2.2. EU DEMO HCPB Divertor Geometrical Model
The calculations were performed using an 11.25° sector model of the EU DEMO reactor with the HCPB breeding blanket configuration, representing 1/32 of the complete 360° geometry. The investigated region included the divertor cassette body (CB), liner and reflector plates (L&Rp), plasma-facing components (PFC), pipelines, and the wishbone [1].
Figure 1 shows the reference MCNP divertor geometry and the locations of the investigated regions.
Figure 1.
MCNP EU DEMO divertor model with the investigated components numbered from 1 to 10: 1—7454, tungsten PFC protective layer; 2—7810, homogenized PFC layer; 3—7990 and 4—8009, titanium cassette components; 5—8005 and 6—8006, INCONEL cassette components; 7—7108, EUROFER pipeline; 8—8070, EUROFER cassette component; 9—7090, water pipe; 10—8484, cassette water cooling channel. Detailed view of (a) the liner and reflector plate geometry and (b) the U-shaped wishbone geometry. [1]
2.3. OpenMC Model Implementation
The OpenMC (v0.16.0) model was developed from the reference MCNP model of the EU DEMO HCPB. Its geometry, cell definitions, material assignments, and surfaces were converted into the OpenMC XML format using the openmc_mcnp_adapter package [19]. Both codes represent geometry using the constructive solid geometry approach.
The model included EUROFER, tungsten, a homogenized W-CuCrZr-H2O mixture, a titanium alloy, INCONEL, and water, with densities of 7.798, 19.000, 9.253, 4.421, 8.221, and 0.926 g/cm3, respectively. These materials represent the main structural and functional components of the divertor. The water-cooled cassette body, liner, and reflector plates are made of EUROFER, with the latter two covered by a 3 mm tungsten layer. The plasma-facing components (PFCs) consist of three homogenized layers and a EUROFER support: the first and third layers contain 99.9595% tungsten, while the second comprises 39.41 vol.% tungsten, 15.92 vol.% CuCrZr alloy, 28.31 vol.% water, and 16.35 vol.% void. The titanium alloy wishbone connects the cassette body to the vacuum vessel and is secured with INCONEL pins [1]. Based on this model, ten cells representing different divertor materials and structural regions were selected to calculate neutron energy spectra and evaluate variations in the neutron energy distribution; their locations and principal characteristics are presented in Figure 1 and Table 1, respectively.
Table 1.
Investigated divertor components.
The physical volumes listed in Table 1 were adopted from the MCNP model and used as common volume divisors for flux normalization.
Fixed-source neutron transport calculations were performed using 50 batches of 2 × 106 neutron histories, corresponding to 1.0 × 108 histories in total. The plasma neutron source was generated using the openmc-plasma-source package [20] and parameterized according to the EU DEMO 2017 plasma configuration [21], represented in Figure 2. The tokamak_source function was used to construct a spatially distributed source on a cylindrical mesh, dividing the plasma volume into radial and vertical elements with assigned neutron emission probabilities. In the final model, the neutron birth energies in all source elements followed a Gaussian distribution with a mean of 14.1 MeV and a standard deviation of 0.294713 MeV. The plasma had a major radius R0 of 8.938 m, a minor radius a of 2.883 m, an elongation κ of 1.650, and a triangularity δ of 0.330.
Figure 2.
EU DEMO 2017 plasma source contour, based on Siccinio et al. [21].
The reference MCNP calculation employed a user-supplied plasma neutron source through the SOURCE subroutine interface, with parameters supplied using the RDUM and IDUM cards, as described in Section 3.3.4.14 of the MCNP User’s Manual [22]. According to the definitions documented in the reference input, the source represented D-T neutron emission with a nominal mean energy of 14.1 MeV and a plasma temperature parameter of 15.4 keV. The plasma parameters matched those used in the OpenMC model, with an additional peaking parameter of 1.508 specified in MCNP. The radial and vertical shifts were zero. The source covered a toroidal interval from 0° to 11.25°, and the documented IDUM entries identify cell 1 as the admissible source cell. The recorded initial source-particle weight was 0.03125, corresponding to the modelled fraction of the full torus. The reference calculation comprised 1.0 × 1010 source histories.
The reference MCNP calculation used the FENDL-3.2 and ENDF/B-VII.1 libraries [1]. In OpenMC, neutron interaction data were primarily obtained from the FENDL-3.2b library, which is specifically evaluated for fusion technology applications [23]. Nuclides unavailable in FENDL-3.2b (75As, 112Cd, 16O, 84Sr, 86Sr, 87Sr, 88Sr, and 180Ta) were supplemented with data from ENDF/B-VIII.0.
2.4. Comparison of OpenMC and MCNP Results
OpenMC neutron spectra were compared with the corresponding results from the reference MCNP model. The magnitude of the energy-resolved discrepancy was quantified using the absolute spectral difference normalized to the reference MCNP flux:
where and are the group-integrated neutron fluxes in energy group i, and N is the number of energy groups. All 709 energy groups were included. This reference-normalized indicator summarizes differences in spectral magnitude and energy distribution while reducing the disproportionate influence of large relative differences in low-flux groups. It is asymmetric and is evaluated without statistical uncertainty weighting; group-wise uncertainties are assessed separately using the spectral error bars and ratio uncertainties.
Integrated neutron fluxes were compared using the OpenMC/MCNP total-flux ratio:
The integrated-flux ratio compares the overall flux magnitude, while the group-wise OpenMC/MCNP ratios describe its energy dependence. Group-wise ratios were evaluated where the MCNP flux was positive:
Their standard errors were estimated using first-order uncertainty propagation, assuming independent OpenMC and MCNP calculations:
Here, and denote the standard errors of the OpenMC and MCNP flux estimates in energy group i, respectively. The OpenMC total and its standard error were obtained from a separate cell flux tally without an energy filter.
The spectra were plotted with error bars representing one standard error for each code. Groups with zero MCNP flux were omitted from the ratio plots but retained in the absolute spectral-difference calculation in Equation (7). The original CCFE-709 energy groups were retained without smoothing.
3. Results
This section presents the statistical quality of the OpenMC calculations, the neutron spectra obtained for ten selected EU DEMO HCPB divertor cells, the spatial distribution of neutron flux, and a comparison with the reference MCNP results reported by Breidokaitė [1,13]. The analysis first evaluates the statistical uncertainty of the OpenMC spectra, followed by an assessment of the influence of region material and geometrical position on the spectral distribution. Finally, the OpenMC and MCNP spectra were plotted together to visually assess their agreement.
3.1. Statistical Quality of the OpenMC Calculations
The statistical uncertainty indicators for the ten investigated cells are presented in Table 2.
Table 2.
Statistical uncertainties of the OpenMC neutron spectra in the investigated divertor regions.
The median and flux-weighted relative uncertainties were below 10% in nine of the ten regions, while the arithmetic-mean uncertainty exceeded 10% in the titanium-alloy cassette component (7990) and the small water pipe (7090).
The PFC protective layer region (cell 7454) showed the lowest median and flux-weighted uncertainties, at 0.726% and 0.431%, respectively, followed by the cooling channel region (cell 8484), at 1.337% and 0.891%. The INCONEL cassette component (8005) and EUROFER cassette component (8070) also exhibited comparatively low flux-weighted uncertainties of 1.860% and 2.218%, respectively. The homogenized PFC layer (7810), titanium-alloy cassette component (8009), INCONEL cassette component (8006), and EUROFER pipeline (7108) had flux-weighted uncertainties between 2.975% and 3.703%, indicating better statistical precision in the groups contributing most strongly to the neutron flux than suggested by their arithmetic-mean uncertainties.
Excluding the small water pipe, the titanium-alloy cassette component (7990) had the highest group-wise uncertainty indicators. Its arithmetic mean reached 12.737%, whereas its median and flux-weighted values were 8.867% and 6.424%. Across all regions, the arithmetic mean exceeded the median, while the flux-weighted indicator was lower than both. This pattern is consistent with large relative uncertainties occurring predominantly in groups contributing comparatively little flux.
The small water pipe (7090) had the highest median, flux-weighted, and arithmetic-mean uncertainties, at 24.038%, 22.934%, and 26.103%, respectively. The elevated flux-weighted value indicates that the larger uncertainties extended to energy groups contributing substantially to the neutron flux.
3.2. Neutron Spectra
Figure 3 shows the OpenMC neutron spectrum and corresponding group-wise relative statistical uncertainties for the tungsten plasma-facing component (cell 7454). The plotted values represent neutron flux integrated over each energy group, without division by the group width. Consequently, variations between adjacent points reflect both the underlying neutron energy distribution and differences in group width. The calculated spectra cover the complete CCFE-709 energy-group structure and include both the high-energy component produced by the D-T fusion source and the lower-energy component formed by neutron scattering and moderation in the divertor materials. Differences between the spectra reflect the material composition, geometrical position, and shielding along the neutron transport path.
Figure 3.
OpenMC group-integrated neutron flux (upper panel) and group-wise relative statistical uncertainty (lower panel) for the tungsten plasma-facing component (cell 7454).
The spectra and corresponding uncertainties for the nine remaining regions are provided in the Supplementary Materials (Figures S1–S9).
The tungsten PFC (7454) exhibited a distinct fast-neutron contribution and a broad lower-energy distribution. Its relatively low statistical uncertainties allowed the spectral structure to be resolved more clearly than in the other components. The homogenized W-CuCrZr-H2O PFC layer (7810) exhibited a lower flux and greater statistical fluctuations, while retaining contributions from both fast and moderated neutrons.
The two titanium-alloy regions (7990 and 8009) showed broadly comparable spectral structures, although their statistical precision differed. The two INCONEL components (8005 and 8006) and the two EUROFER (7108 and 8070) components likewise exhibited broadly similar spectral patterns within each material pair, with differences in flux magnitude and local fluctuations. These variations are consistent with differences in material composition and the surrounding geometrical environment.
The large water-cooling channel (8484) exhibited a pronounced lower-energy contribution consistent with neutron moderation. The spectrum of the small water pipe (7090) showed greater point-to-point fluctuations, consistent with its higher group-wise statistical uncertainties.
3.3. Spatial Distribution of Neutron Flux and Statistical Uncertainty
The energy-integrated neutron-flux map showed a spatial gradient across the displayed divertor section (Figure 4a). The voxel-averaged flux ranged from approximately 1.68 × 109 to 3.52 × 1014 n/(cm2s), with higher values in the upper regions and lower values towards the lower divertor structures. This pattern is consistent with neutron attenuation and redistribution through scattering and absorption in the surrounding components.
Figure 4.
Spatial OpenMC results for the x–z mesh slice centred at y = 70.833 cm: (a) energy-integrated neutron flux; (b) corresponding relative statistical uncertainty.
The mesh resolves the overall spatial flux distribution at voxel scale and complements the cell-averaged results for individual components.
Figure 4b shows the relative statistical uncertainty of the energy-integrated voxel flux. All 1200 voxels in the displayed slice had positive flux, with median and maximum relative uncertainties of 0.503% and 3.872%, respectively. These values indicate comparatively high statistical precision in the displayed slice.
3.4. Comparison Between OpenMC and MCNP Results
The OpenMC and MCNP neutron spectra were compared using overlaid spectra and OpenMC/MCNP ratio plots, with a ±10% interval used as a practical visual reference. Spectral differences were quantified using the reference-normalized absolute spectral difference defined in Equation (7). Integrated fluxes were compared using the OpenMC/MCNP flux ratio defined in Equation (8). Large ratios in low-flux energy groups were interpreted together with the statistical uncertainties of both calculations.
For the comparison presented in Table 3, energy groups with an OpenMC/MCNP flux ratio greater than 20 were excluded. Groups with zero MCNP flux were also excluded because their flux ratio was undefined. The reference-normalized absolute spectral difference and the integrated flux ratio were calculated using the same retained energy groups for each cell. MCNP group-wise uncertainty summaries are provided in Appendix A, Table A1, while comparisons within selected neutron-energy ranges are reported in Table A2 (the OpenMC/MCNP ≤ 20 selection used in Table 3 was not applied to the Appendix tables).
Table 3.
Reference-normalized absolute spectral differences and integrated OpenMC/MCNP flux ratios for energy groups satisfying OpenMC/MCNP ≤ 20.
For cells 7454, 7810, 7990, 8009, 8005, 8006, 7108, 8070, 7090 and 8484, respectively, the numbers of energy groups excluded because OpenMC/MCNP > 20 were 1, 1, 0, 3, 0, 0, 0, 2, 0 and 19. The Appendix tables report results without this upper-ratio exclusion.
The reference-normalized absolute spectral difference ranged from 8.36% to 17.65% across the nine regions other than the small water pipe (7090). The lowest difference was obtained for the cassette water-cooling channel (8484), followed by the tungsten PFC (7454), at 10.51%. The homogenized W-CuCrZr-H2O layer (7810) showed a difference of 11.81%, while the titanium-alloy cassette component (7990) exhibited the largest difference among these nine regions, at 17.65%.
For the tungsten PFC (7454), shown in Figure 5, the reference-normalized absolute spectral difference was 10.51%. The integrated OpenMC/MCNP flux ratio calculated over the retained energy groups was 1.11, corresponding to an approximately 10.51% higher OpenMC flux. The similar magnitudes of these two indicators suggest that the overall flux offset accounts for most of the absolute spectral difference in this cell.
Figure 5.
Comparison of the OpenMC and MCNP neutron spectra for the tungsten plasma-facing component (7454), with the corresponding OpenMC/MCNP ratios and group-wise relative statistical uncertainties. The vertical dotted lines mark the thermal–epithermal boundary at 0.63096 eV and the epithermal–fast boundary at 100 keV, consistent with the energy ranges reported in Table A2.
Across the ten regions, the integrated OpenMC/MCNP flux ratios calculated over the retained groups ranged from 1.07 to 1.13, corresponding to OpenMC fluxes approximately 7.42–13.10% higher than the MCNP values. These results were obtained after retaining groups with positive MCNP flux and OpenMC/MCNP ≤ 20. The unfiltered, directly scored integrated fluxes and their standard errors are reported in Appendix B, Table A3.
The small water pipe (7090) exhibited a reference-normalized absolute spectral difference of 58.16%, while its integrated OpenMC/MCNP flux ratio over the retained groups was 1.10. Its unfiltered integrated OpenMC flux was 6.49 ∙ 1013 n/cm2s, with a relative standard error of approximately 2.2% (Table A3). The flux-weighted group-wise uncertainties were 22.93% for OpenMC and 7.80% for MCNP (Table 2 and Table A1). These indicators characterize the precision of the energy-resolved spectra and are distinct from the uncertainty of the integrated flux. The flux magnitude is a volume-averaged quantity governed by the local neutron field; a small cell can therefore have a flux comparable to that of a much larger component.
Excluding the largest ratios mainly improves the readability of the ratio plots. For the 20-fold cutoff, the removed groups account for no more than 0.0011% of the OpenMC spectral flux in any region. Consequently, the exclusion changes the reference-normalized absolute spectral differences only slightly. The unfiltered appendix results preserve the contributions of these groups and provide the complementary full-spectrum context.
Overall, integrated OpenMC fluxes over the retained energy groups were 7.42–13.10% higher than the MCNP values, while reference-normalized absolute spectral differences ranged from 8.36% to 58.16%. Additional comparisons for the remaining regions are provided in the Supplementary Materials (Figures S10–S18).
4. Discussion and Conclusions
This study compared OpenMC neutron spectra with reference MCNP results for ten EU DEMO HCPB divertor regions. For energy groups with positive MCNP flux and OpenMC/MCNP ≤ 20, integrated flux ratios ranged from 1.0742 to 1.1310, corresponding to approximately 7.42–13.10% higher OpenMC fluxes. The reference-normalized absolute spectral difference ranged from 8.36% to 17.65% in nine regions and reached 58.16% in the small water pipe (7090). These results indicate differences in both overall flux magnitude and energy distribution. The appendix tables report results without the upper-ratio exclusion.
Cell 7090 showed the largest spectral discrepancy and the highest flux-weighted group-wise uncertainty. This contrast with the other regions highlights the importance of assessing energy-resolved statistical precision alongside the overall flux magnitude.
The model-transfer issues reported by Park [12] provide relevant context for the present comparison. Both calculations relied primarily on the FENDL-3.2 library family, although supplementary nuclear data differed. Source representation, normalization conventions, and geometry conversion remain potential contributors to the observed differences, but their individual contributions were not quantified. The component-specific results identify where the largest discrepancies occur and provide a basis for targeted comparisons with harmonized calculation settings.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/app162311775/s1, The accompanying supplementary file contains additional OpenMC neutron spectra and their group-wise relative statistical uncertainties (Figures S1–S9), together with additional OpenMC–MCNP spectral comparisons, flux ratios, and statistical uncertainties (Figures S10–S18).
Author Contributions
Conceptualization, I.S.; methodology, software, I.S. and G.S.; validation, I.S.; formal analysis, investigation, I.S.; resources, S.B. and G.S.; data curation, S.B. and G.S.; writing—original draft preparation, I.S.; writing—review and editing, S.B. and G.S.; visualization, I.S. and S.B.; supervision, G.S. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The data presented in this study are available on request from the corresponding author.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| EU | European Union |
| DEMO | Demonstration fusion power plant |
| HCPB | Helium-Cooled Pebble Bed |
| OpenMC | Open-source Monte Carlo particle transport code |
| MCNP | Monte Carlo N-Particle |
| ITER | International Thermonuclear Experimental Reactor |
| D-T | Deuterium–tritium |
| CCFE | Culham Centre for Fusion Energy |
| FENDL | Fusion Evaluated Nuclear Data Library |
| MAGIC | Method of Automatic Generation of Importances by Calculation |
| PFC | Plasma-Facing Component |
| XML | Extensible Markup Language |
Appendix A
This appendix provides additional statistical summaries for the reference MCNP spectra and OpenMC–MCNP comparisons within selected neutron-energy ranges. Table A1 reports group-wise uncertainty indicators calculated over energy groups with positive MCNP flux.
Table A1.
Group-wise relative statistical uncertainties of the reference MCNP spectra.
They summarize group-wise relative statistical uncertainties and do not represent the uncertainty of the integrated flux.
Table A2 compares the spectra within thermal, epithermal, and fast energy ranges using the OpenMC/MCNP flux ratio and the reference-normalized absolute spectral difference defined in Equation (7), evaluated separately within each range. The boundaries follow the existing CCFE-709 energy-group edges and are reported explicitly in the table. The upper boundary of 109 eV is the upper limit of the CCFE-709 tally structure. These comparisons help identify energy ranges contributing to the overall spectral discrepancies.
Table A2.
OpenMC-MCNP flux ratios and reference-normalized absolute spectral differences within selected neutron-energy ranges.
Appendix B
Table A3 reports the directly scored integrated neutron fluxes and their standard errors for OpenMC and MCNP.
Table A3.
Integrated OpenMC and MCNP neutron fluxes and their statistical uncertainties.
The OpenMC integrated fluxes and standard errors were obtained from separate cell flux tallies without an energy filter. The MCNP values were obtained from the total entries of the corresponding tallies. Both results were normalized as described in Section 2.1. Table A3 reports the complete integrated fluxes without the upper-ratio exclusion applied in Table 3. The ratios in Table 3 were calculated separately from sums over the retained energy groups. Values in Table A3 are rounded for presentation.
References
- Breidokaitė, S. Modeling of the Neutron Transport Based on the Monte Carlo Method and the Numerical Estimation of Radiological Quantities Towards the Future Nuclear Fusion Reactor DEMO. Ph.D. Thesis, Lithuanian Energy Institute, Kaunas, Lithuania, 2025. [Google Scholar]
- You, J.H.; Mazzone, G.; Visca, E.; Greuner, H.; Fursdon, M.; Addab, Y.; Bachmann, C.; Barrett, T.; Bonavolontà, U.; Böswirth, B.; et al. Divertor of the European DEMO: Engineering and technologies for power exhaust. Fusion Eng. Des. 2022, 175, 113010. [Google Scholar] [CrossRef] [Scilit]
- Noce, S.; Flammini, D.; Mariano, G.; Moro, F.; Romanelli, F.; Villari, R.; You, J.H. Neutronics analysis and activation calculation for tungsten used in the DEMO divertor targets: A comparative study between the effects of WCLL and HCPB blanket, different W compositions and chromium. Fusion Eng. Des. 2021, 169, 112428. [Google Scholar] [CrossRef] [Scilit]
- Commissariat à l’énergie atomique et aux énergies alternatives (CEA). TRIPOLI-4. Available online: https://www.cea.fr/energies/tripoli-4/Pages/Accueil.aspx (accessed on 6 November 2026).
- Leppänen, J.; Valtavirta, V.; Rintala, A.; Tuominen, R. Status of the Serpent Monte Carlo code in 2024. EPJ Nucl. Sci. Technol. 2025, 11, 3. [Google Scholar] [CrossRef] [Scilit]
- CERN. About FLUKA. Available online: https://fluka.cern/about (accessed on 6 November 2026).
- Geant4 Collaboration. Overview. Available online: https://www.geant4.org/about/ (accessed on 6 November 2026).
- Romano, P.K.; Horelik, N.E.; Herman, B.R.; Nelson, A.G.; Forget, B.; Smith, K. OpenMC: A state–of–the–art Monte Carlo code for research and development. Ann. Nucl. Energy 2015, 82, 90–97. [Google Scholar] [CrossRef] [Scilit]
- OpenMC Python API. Available online: https://docs.openmc.org/en/stable/pythonapi/index.html (accessed on 27 August 2026).
- Segantin, S.; Ebiwonjumi, B.; Peterson, E. Validation of the OpenMC Code for Fusion Applications: The FNG-Streaming Benchmark Case. Fusion Sci. Technol. 2025, 81, 437–447. [Google Scholar] [CrossRef] [Scilit]
- Afanasenko, E.S.; Portnov, D.V.; Vysokikh, J.G.; Kashchuk, Y.A. Synchronization of the OpenMC and MCNP Models for ITER Neutronics. Fusion Sci. Technol. 2026, 82, 805–813. [Google Scholar] [CrossRef] [Scilit]
- Park, J.H. Neutronics Benchmark of European DEMO and VNS Using MCNP and OpenMC for the Eurofusion Programme. In Proceedings of the OpenMC Application to Tokamak Neutronics Analysis Meeting, Lemont, IL, USA, 4 June 2025. [Google Scholar]
- Breidokaite, S.; Stankunas, G. Neutron Flux in EU DEMO Divertor Cassette Body Using HCPB and WCLL Breeding Blanket Models. J. Fusion Energ. 2022, 41, 14. [Google Scholar] [CrossRef] [Scilit]
- OpenMC Theory and Methodology. Random Ray. Available online: https://docs.openmc.org/en/stable/methods/random_ray.html (accessed on 29 August 2026).
- OpenMC Theory and Methodology. Introduction. Available online: https://docs.openmc.org/en/stable/methods/introduction.html (accessed on 29 August 2026).
- OpenMC Theory and Methodology. Tallies. Available online: https://docs.openmc.org/en/stable/methods/tallies.html (accessed on 29 August 2026).
- OpenMC Theory and Methodology. Neutron Physics. Available online: https://docs.openmc.org/en/stable/methods/neutron_physics.html (accessed on 29 August 2026).
- OpenMC Theory and Methodology. Variance Reduction. Available online: https://docs.openmc.org/en/stable/methods/variance_reduction.html (accessed on 29 August 2026).
- openmc-dev/openmc_mcnp_adapter. MCNP Conversion Tools for OpenMC. Available online: https://github.com/openmc-dev/openmc_mcnp_adapter (accessed on 29 August 2026).
- Fusion-Energy/Openmc-Plasma-Source. OpenMC-Plasma-Source. Available online: https://github.com/fusion-energy/openmc-plasma-source (accessed on 29 August 2026).
- Siccinio, M.; Graves, J.P.; Kembleton, R.; Lux, H.; Maviglia, F.; Morris, A.W.; Morris, J.; Zohm, H. Development of the plasma scenario for EU-DEMO: Status and plans. Fusion Eng. Des. 2022, 176, 113047. [Google Scholar] [CrossRef] [Scilit]
- Werner, C.J.; Armstrong, J.C.; Brown, F.B.; Bull, J.S.; Casswell, L.; Cox, L.J.; Dixon, D.A.; Forster, R.A., III; Goorley, J.T.; Hughes, H.G., III; et al. MCNP User’s Manual Code Version 6.2; Report LA-UR-17-29981; Los Alamos National Laboratory: Los Alamos, NM, USA, 2017. [Google Scholar]
- International Atomic Energy Agency. Fusion Evaluated Nuclear Data Library—FENDL-3.2b. Available online: https://nds.iaea.org/fendl_library/websites/fendl32b/ (accessed on 29 August 2026).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.