Featured Application
Open-source reconstruction and calibration workflow for high-altitude EAS-core measurements with ionization calorimeters.
Abstract
We present an open, scripted reconstruction pipeline for the ADRON-55 ionization calorimeter at the Tien Shan station (3340 m a.s.l.) and apply it to events from 2021 and 2023. It assembles overlapping chamber sections, applies data-driven integrity and good-run selection (16.3% flagged), and fits three-dimensional directions from hadron-block planes with material-based weights. Plane occupancy falls with depth to 0.75 (X) and 0.61 (Y) at the deepest plane of each projection, while per-channel deposition is nearly uniform across X planes, revealing a projection-dependent efficiency offset whose size, and for the deepest plane pair whose sign, depend on the amplitude threshold. One-pitch lateral profiles resolve a narrower gamma-block component, RMS against m; the gamma figure is an upper limit, since the events carrying half its amplitude clip the digitizer, and without them it is 0.507 m. For 990 single tracks with three active planes in each projection, the azimuthal flatness statistic improves from to 15.8 after assembly, seeding, and alignment. We then locate the residual: in four fifths of that sample a plane is lit edge to edge and carries no core, so its centroid reports the aperture rather than the particle, and the alignment maps those events onto a zero-slope line that pins their azimuth to the detector axes. Removing them leaves , and 1.2 on events held out of a re-derived alignment; a detector-level simulation carrying the measured channel efficiencies then reproduces that sub-sample with an isotropic parent. The code and diagnostics are released, making the figures reproducible from raw data.
1. Introduction
Extensive air showers (EAS) remain one of the few practical windows on hadronic interactions at center-of-mass energies beyond the reach of colliders. The most energetic secondaries of a shower stay close to its axis and form a dense core, and the way this core develops and is absorbed in a thick calorimeter carries information about the primary particle and about the interaction models used to describe it. The Tien Shan mountain station, at 3340 m above sea level, has been used for this kind of measurement for several decades. Experiments there reported three effects that do not fit comfortably within the standard description of hadronic interactions [1,2,3]: a sharp scaling violation in the fragmentation region; an unexpectedly slow attenuation of core hadrons in a large lead calorimeter, known in the literature as the Tien Shan effect; and coplanar emission of the most energetic secondaries in super-families. These observations, made with an earlier generation of X-ray emulsion chambers and a 36 m2 lead ionization calorimeter, motivated the construction of a larger and more capable instrument.
That instrument is the HADRON-55 complex, whose central element is the ADRON-55 ionization calorimeter (both transliterations appear in the literature): a two-storey, 55 m2 coordinate calorimeter with about 1220 g/cm2 of absorber [4,5]. An upper gamma block registers the electromagnetic component of a shower core; a 22 cm (≈250 g/cm2) lead target and a 2.2 m decay gap then separate it from the deep, iron-interleaved hadron block that samples the surviving cascade in crossed projections with a position granularity of order 10 cm. In the hadron block, each X plane is read out in three sub-rows rather than the gamma block’s two. This detail is fixed in the original instrument description [5] and turns out to matter for the present analysis. The scientific program of the setup focuses on EAS-core physics: the spectrum and composition of primaries, the coplanarity phenomenon, and the anomalous absorption of core hadrons [6]. Recent work by the collaboration has added Hadr55, a dedicated Geant4-based simulation of the passage of shower particles through the calorimeter [7,8,9].
While the physics goals are well defined, the software that turns the raw signals into physical quantities has grown incrementally and was never released or described in a form that others could reproduce: the hardware is documented in the literature, but the reconstruction lives in private scripts whose assumptions are recorded nowhere. That reconstruction covers raw-format decoding, channel calibration, plane alignment, data selection and track finding. Large cosmic-ray observatories treat the reconstruction chain as a documented, released product in its own right; the Offline framework of the Pierre Auger Observatory is the standard example [10]. Open release of the processed data has followed the same path, the KASCADE Cosmic-ray Data Centre being the most developed case in air-shower physics [11]. The wider move towards findable, accessible, interoperable and reusable research outputs [12], towards citing software as a first-class product [13], and towards analyses that can be re-executed from their inputs [14], has raised the same expectation for smaller installations. For an instrument that intends to publish core-level results and compare them with detailed simulation, the omission matters concretely. Without a documented chain, genuine detector effects cannot be separated from artifacts of the processing, and the physics sought at this station is itself anomalous.
This paper closes the gap. We describe an open analysis pipeline that takes ADRON-55 from its raw data format to reconstructed three-dimensional tracks and calibrated observables, and we use it to characterize the detector response. The pipeline is written in Python 3.14 and organized as documented modules: decoding and stitching of the raw chamber data, cluster finding, road-search tracking in the two projections, hybrid matching into three-dimensional tracks, and a set of calibration steps. Two of the latter are data-driven and, to our knowledge, had not been applied systematically to this instrument before: a channel-to-position calibration that accounts for the differing plane widths, and a track-based alignment that removes residual plane offsets using the tracks themselves. A third step, the automatic detection and exclusion of data-taking runs with inactive readout cameras, proved necessary as soon as the data were examined file by file. On the events recorded in the 2021 and 2023 seasons we measure the three response characteristics on which the core-physics program rests: the longitudinal development of the signal with depth, the transverse profile of the deposition, and the angular distribution of reconstructed tracks. Our aim is deliberately methodological. The angular and longitudinal behavior of cosmic rays at this depth is well known, and we use that knowledge as the test. An azimuthal distribution consistent with isotropy, and an absorption curve falling smoothly with depth, are the evidence that the reconstruction does what it should. We state explicitly what the present processing can and cannot support, and we release both the code and the raw data with persistent identifiers so that the analysis can be repeated and extended. Section 2 summarizes the instrument and the data set; Section 3 the pipeline, its calibrations, and the quality selection; Section 4 the longitudinal, transverse, and angular response; Section 5 discusses the limitations and the steps toward a quantitative comparison with simulation; Section 6 concludes.
2. The Instrument and the Data Set
2.1. The ADRON-55 Ionization Calorimeter
The Tien Shan station stands at 3340 m above sea level ( N, E), where the mean atmospheric depth is about 690 g/cm2 and air showers are recorded close to the maximum of their development [5]. The core detector of the HADRON-55 complex is a coordinate ionization calorimeter with a sensitive area of 55 m2 and a total thickness of roughly 1250 g/cm2. Its sensitive elements are rectangular ionization chambers, 3 m long and cm2 in cross-section, made of copper waveguide, filled with argon at two atmospheres and read out through a central 3 mm anode held at 600 V. The chambers are grouped into nine registration layers. The lowest was installed but never connected to the readout, so it contributes no data in the seasons analyzed here, and only eight planes are used throughout this paper. Within each successive pair the long axes of the chambers are rotated by . Alternate layers therefore sample the two orthogonal transverse coordinates, and a two-dimensional image of the ionization can be followed layer by layer down the stack. The transverse granularity set by the chamber width is of order 10 cm, and each channel is digitized in two overlapping amplitude ranges spanning a dynamic range of a few .
The calorimeter is built in two tiers [5]. The upper gamma block consists of two crossed chamber rows interleaved with lead amounting to about eight radiation lengths (45 mm of lead), in which the electromagnetic part of a shower core develops. Each row is split into two oppositely oriented halves, so that a single row is read out as two facing sections. Following the hardware naming, we refer to these as the left/right pair in one projection and the front/back pair in the other. Immediately below the gamma block, a 22 cm (≈250 g/cm2) lead target absorbs what survives of the electromagnetic component and supplies the material in which core hadrons interact; a 2.2 m air gap then follows, giving short-lived secondaries room to decay before they reach the lower tier. The hadron block is a deep stack of ionization-chamber layers interleaved with iron absorber, 1020 mm of iron in all, about 800 g/cm2. Together with the lead converter, this amounts to six to seven nuclear interaction lengths. In each of its X-projection layers, the chambers are arranged in three sub-rows rather than the two of the gamma block [5]. Between the fourth and fifth planes the stack carries, besides the iron, 60 mm of neutron counters belonging to the complex rather than to the calorimeter; they are not absorbers and are taken to add no depth. This difference must be handled correctly when the raw channels are assembled into a position measurement (Section 3). The depth of the stack makes the instrument a calorimeter in the usual sense [15]: the primary hadron energy can be estimated, to about 20–25%, from the integral of the ionization curve traced through the successive layers. Figure 1 shows the arrangement to scale.
Figure 1.
(Color online.) Cross-section of the ADRON-55 ionization calorimeter, drawn to scale in both coordinates from the same detector description that the reconstruction reads. Eight-chamber planes alternate between the two projections; the X planes span 48 channels of 120 mm and the Y planes 72, so the two projections cover different transverse extents, which is why Equation (3) centers each plane on its own width. The gamma block of two planes is separated from the six hadron-block planes by the 220 mm lead target, the 2.2 m decay gap and the 130 mm lead converter; the vertical axis is broken across that span, and each panel is to scale. The 100 mm between planes 4 and 5, which carries neutron counters of the complex, is not an absorber and is marked as such. The ninth plane, drawn in grey at the foot of the stack, is installed and appears on the calorimeter drawing of the instrument papers, but has never been connected to the readout: no section of the raw event record corresponds to it, and it carries no depth entry here. The right-hand columns give the plane number, its projection, its channel count and transverse width, and the cumulative absorber depth above it in nuclear interaction lengths (Table 1).
Two aspects of the design bear directly on what follows. Because the chambers record the transverse position of the ionization at each depth, the calorimeter can in principle reconstruct the arrival direction of a track from the displacement of its footprints across the layers. This possibility was noted in the original instrument description as an independent, complementary alternative to the scintillator timing method [5], and the angular results of Section 4 realize it. The thick lead target and air gap between the two tiers, in turn, decouple them from the point of view of a single traversing particle. A segment seen in the hadron block and a signal recorded in the gamma block need not lie on a common straight line, because multiple scattering and secondary production in the intervening 22 cm of lead break the trajectory. The effect is physical, and it dictates how the tracking must be organized.
Table 1 summarizes the geometry used by the reconstruction: the height, projection, and channel count of each plane, and the cumulative absorber depth above it, computed from the tabulated interaction and radiation lengths of the absorber materials [16]. The depths quoted throughout this paper and on the horizontal axes of Section 4 are those above the active planes and therefore reach at the deepest plane; the absorber below the eighth plane adds a further ≈1.7.
Table 1.
Geometry of the eight active chamber planes and the cumulative absorber depth above each plane, as used by the reconstruction. Depths are summed from the top of the stack; the channel pitch is 120 mm throughout. The gamma block (planes 1–2) is separated from the hadron block (planes 3–8) by the 220 mm lead target, a 2.2 m air gap, a 130 mm lead hadron converter, and the first 100 mm iron layer. The 60 mm of neutron counters between planes 4 and 5 belong to the complex rather than to the calorimeter; they are listed because they occupy the space, and are taken to add no depth. The depths are computed with the tabulated values of mm and mm for lead, mm and mm for iron, and m and m for air [16], being the nuclear interaction length in every case. In the column heading the symbol X is a thickness of material, not the transverse coordinate of the X projection.
One entry of Table 1 is not settled by the literature, and we state it rather than leave a reader to find it. The calorimeter drawing of the instrument papers gives 50 mm of lead above plane 1 [5,17], where the description used here carries 30 mm. The published depths do not choose between them: 50 mm reproduces the total absorber thickness of 1150 g/cm2 quoted for the calorimeter [17] to 0.1%, giving 1148 g/cm2 at the ninth row, while 30 mm reproduces the per-plane depths of 940 and 1018 g/cm2 at planes 7 and 8 [7] to half a per cent, giving 945 and 1023. The two published anchors are mutually inconsistent by about the 23 g/cm2 that the disputed 20 mm of lead represents. We keep 30 mm, which is the value the released configuration has always carried, and flag the discrepancy: it shifts every entry of the column by 0.11 and the depth axis of the longitudinal profile of Section 4.1 with it, but it enters no reconstructed quantity and leaves every depth difference between hadron-block planes unchanged, those being set by the iron. The 220 mm lead target between the blocks, by contrast, is stated in the text of both instrument papers and drawn in both, and is not in doubt.
2.2. Data Set and Raw Format
Each trigger produces one event record in a plain-text format: a header line with the timestamp and an event counter, followed by one line of ADC amplitudes per readout section. The submitted version of this paper stated that every channel is digitized in two overlapping amplitude ranges. That is not the case, and the correction matters for what can be recovered: over all 263 raw files and 291,360 events, exactly five sections carry a second range. They are the four sections of the gamma block, which carry a low sensitivity row, and the scintillator carpet, which carries a midi sensitivity row. None of the fifteen hadron-block sections has one. The present analysis uses the high-sensitivity rows only; Section 4.4 and Section 4.2 report what that costs in the gamma block, which is the only place where it can cost anything, and Section 3.1 explains why the gamma low-sensitivity row is not used to recover it. The saturation veto of Section 3.2 refers to the upper end of the high-sensitivity range. The data set comprises 291,358 event records from the 2021 and 2023 observing seasons in 263 daily files. An integrity audit of the raw files (Section 3.5) identified 3575 events duplicated between six pairs of files and 656 events in two files misfiled from 2022; these are flagged and excluded from all analysis samples, leaving 287,127 unique in-season events, of which 243,746 belong to good runs.
The two projections are interleaved through the stack: the odd layers (planes 1, 3, 5, 7) measure the X coordinate and the even layers (planes 2, 4, 6, 8) measure Y, with the two gamma-block planes at the top (planes 1 and 2) followed by the six hadron-block planes. Because a physical chamber row is assembled from two or three overlapping sections read out from opposite ends, the mapping from the raw per-section arrays to a single position coordinate along a row requires care; establishing it correctly is one of the calibration steps described in Section 3. The arrangement is corroborated by the instrument papers: the hadron-block X layers carry a third, middle sub-row of chambers that the Y layers and the gamma block do not [5], and the chamber counts given there for the readout channels—238 for the gamma block, 144 for each hadron-block layer—are twice the 50 and 69 channels of planes 1 and 2, three times the 48 channels of an X plane, and twice the 72 of a Y plane. Throughout the paper we index the planes 1–8 from the top of the calorimeter downward, so that plane 1 is the uppermost gamma-block row at a height of 4275 mm above the reference level and plane 8 is the lowest active hadron-block row at 470 mm.
Two further fields of the record are not used by the pipeline and are described here because the raw data are released and a user will meet them without explanation. The first is the trigger. A carpet of 30 plastic scintillation counters covering about 320 m2 sits above the calorimeter. The trigger of the facility is a threshold on a summed analogue amplitude, not a coincidence: the shower trigger of the registration point fires when the momentary sum of scintillation amplitudes over the carpet exceeds a preset discriminator level, and the calorimeter’s own local trigger is formed by summing the high-sensitivity outputs of its ionization chambers in fixed combinations of readout sections [5]. Of the several modes the trigger subsystem provides, the one in use sums the ionization of the two gamma-block planes [17]. The 30 amplitudes are recorded with each event, in two gain ranges, under the section name scinti, and the pipeline discards them.
What that field contains is consistent with a summed trigger and would not be with a coincidence one, so we report the check. Counting the counters whose recorded amplitude is non-zero, the median run has 11 of 30 and the distribution is bimodal from run to run: of the 263 runs, 102 have a median of six or fewer and 84 have a median of 25 or more, and over the first 50,000 good-run events, all 30 counters respond in only 6.6% of them. A trigger requiring every counter to respond could not produce such an archive; a threshold on the summed amplitude produces it naturally, since the sum can pass the threshold with a minority of the carpet lit. The trigger efficiency as a function of primary energy still cannot be obtained from these records, because the facility does not write the events the trigger rejected; but the quantity it is a function of is now defined, namely the energy deposited in the two gamma-block planes, and a shower simulation carrying the detector response can compute it. What the field does provide is a shower-size estimator that the present analysis throws away: the median calorimeter sum rises from ADC counts in events with ten or fewer counters responding to in events with all 30. Using it is the shortest route to the event-by-event energy estimate that Section 5 lists as a prerequisite for the physics program.
3. Reconstruction Pipeline
The pipeline turns the raw per-section amplitudes of an event into calibrated, three-dimensional tracks through a fixed sequence of stages. The channels of each chamber row are first assembled into a single position profile (Section 3.1); contiguous groups of channels are then identified as clusters, and events dominated by saturation or incoherent noise are rejected by a set of veto conditions (Section 3.2). A road-search algorithm builds candidate tracks independently in the two projections, working within the hadron block, and the two projections are matched into three-dimensional tracks that are fitted in a common metric coordinate system (Section 3.3). Superimposed on this flow are three data-driven calibration and quality procedures that we found to be necessary for unbiased results and that constitute the main methodological content of this work: a channel-to-position calibration that accounts for the differing plane widths, a track-based alignment of the planes, and an automatic selection of good data-taking runs (Section 3.4 and Section 3.5). The pipeline is implemented in Python and released in full (see the Data Availability statement); each stage is a separate, documented module, and the diagnostic scripts used to derive the calibrations are distributed alongside it. The subsections below follow the pipeline in processing order: assembly of the raw sections into one profile per plane, cluster finding and vetoes, track finding and the three-dimensional fit, the channel-to-position calibration and the plane alignment, and the good-run audit. Each stage writes its own diagnostic output, and the released code reproduces every figure and table of this paper from the raw files.
3.1. Assembly of the Raw Signal
The first task is to turn the several amplitude arrays that describe one chamber row into a single ionization profile along that row. This step is non-trivial because of the way the rows are instrumented. As described in Section 2, each row is read out as two sections in the gamma block, or three in the hadron-block X planes, physically stacked at slightly different depths and read from opposite ends. These sections overlap in the transverse coordinate they measure instead of tiling it, and that is what determines the correct assembly. They cover the same set of positions along the row, at different depths, rather than adjacent segments of a longer line. The detector channel map states this explicitly. The first channel of every section of a row maps to the same transverse position; in the top X plane the first channels of the left and right sections coincide, and in a hadron-block X plane the first channels of the right, middle, and left sections all coincide, with the channel indices then running together across the row.
Because a single particle crosses the row at one depth, at any given transverse position at most one section carries signal, and the amplitude at that position is recovered by summing the sections channel by channel with their indices aligned. Reversal and truncation are the two natural errors here, and each leaves a characteristic imprint. The first is to reverse one section before summing, on the supposition that facing sections are mirror images of one another; with the actual channel map, reversal pairs a position on one side of the row with its mirror on the other and folds the coordinate about the row center. The second is to let a partially read section define the length of the assembled row. In a given event the valid data of a section, delimited by the end-of-record marker, may be shorter than the rest; taking that length truncates the full-width sections to the shortest one and collapses the position measurement. In the present pipeline each section is padded to the nominal length of its row (50 channels for the gamma-block X plane, 69 for the gamma-block Y plane, and 48 or 72 channels for the hadron-block X and Y planes) and the sections are summed by index, without reversal and without truncation. The prescription was checked against the data and not taken from the channel map alone. The quality of the two-projection track fits and the azimuthal distribution of the reconstructed tracks are both highly sensitive to how the sections are combined, and only with this assembly do both behave as they should, giving well-formed tracks and a much flatter azimuth, as Section 4 shows. Establishing the assembly correctly is therefore a prerequisite for every subsequent step.
Two properties of the raw format are worth recording, because a referee asked about one of them and because neither is evident from the files. First, the second readout range. Over all, 263 raw files and 291,360 events—exactly five sections carry one: the four sections of the gamma block, which carry a low sensitivity row, and the scintillator, which carries a midi sensitivity row. No hadron-block section has a second range, so for the tracking, the alignment and every angular result of this paper, there is nothing to recover with. The released loader reads only the high-sensitivity rows, and Section 4.2 measures what that costs, where it can cost anything, in the gamma block. We do not use the gamma low-sensitivity row either, for a reason that is itself a measurement: where the high range is at its 4095-count ceiling, the low range reads above 1000 counts in 8% of cells, and 61,351 of those 61,689 cells come from a single run; in every other run the low range is empty exactly where the high one is full. Where both are on scale, their ratio has a median near 140 and a 16–84 percentile range of 60 to 540, a factor of nine, so one cannot be calibrated from the other on these data. What the row records is not documented in any material available to us, and we report it as an open question rather than guess.
Second, the format carries a sentinel, which the loader reads as a number. It marks twelve permanently dead channels: one each in the back_1, back_3, front_1, front_2 and front_3 sections, three in middle_1 and four in middle_2. Read as a number, a dead channel is indistinguishable from a channel that was not hit. The distinction does not affect the results reported here, since those channels are empty in either reading and the per-channel profile records them as such, but it is a correctness issue in the released loader and will be fixed in the next release.
3.2. Cluster Finding and Event Rejection
Once a plane has been assembled into a single profile, its signal is reduced to a small number of clusters. A cluster is a contiguous run of channels whose amplitudes exceed a fixed threshold of 30 ADC counts in the standard configuration. It is retained if it contains at least one channel and if its summed amplitude exceeds a minimum of 50 counts. Each cluster is summarized by two numbers: its amplitude-weighted centroid—the transverse position of the signal in that plane—and its total amplitude, which measures the deposited energy. This fixed-threshold, contiguity-based definition is a one-dimensional simplification of the seed-and-grow topological clustering used in modern calorimeters [18]; with 48–72 channels per plane, a single global threshold keeps the procedure transparent. Clusters are the unit on which everything downstream operates: the track finder links them across planes, and the response profiles of Section 4 are built from them.
A second and lower threshold enters separately. The plane occupancy of Section 4.1 counts a plane as active when any of its channels reaches 5 ADC counts; that value is an independent parameter of the configuration and not the clustering threshold of 30, so varying one says nothing about the other. Occupancy does depend on the threshold that defines it. Section 4.1 gives it at five values between 5 and 30 counts on the full good-run sample: across the hadron block it falls by between 15.5 and 38.5 percentage points, and plane 7 loses more than half of its occupancy. What that permits us to conclude, and what it does not, is set out in Section 4.1.
A single global threshold also assumes that a channel reads zero when no particle crosses it, and we have tested the assumption rather than made it. Taking the pedestal of a channel to be the median of its amplitude over all 243,744 good-run events—an estimator that needs no dedicated pedestal run and that is robust as long as a channel carries genuine signal in fewer than half the events, which holds here by an order of magnitude—52 of the 479 channels sit above zero and 13 above 5 counts, the largest at or above 511. A channel resting at 35 counts is active in every event by the definition above and enters the occupancy of its plane whether or not a particle crossed it. Subtracting the measured pedestals lowers the occupancies reported in Section 4.1, which are taken at a 5-count threshold, by at most 0.10, and changes none of the conclusions drawn from them. At the 30-count threshold used there the effect is larger and reverses the ordering of planes 5 and 4, as Section 4.1 reports. The values quoted throughout are the uncorrected ones, and the pedestal measurement is released with the diagnostics.
Not every recorded event is a candidate for tracking, and a set of veto conditions removes those that are not before any tracking finding is attempted. Four conditions are applied to the assembled planes. A saturation veto rejects events in which a large fraction of channels sit at the maximum digitized value, a pattern produced by electromagnetic interference or a readout fault rather than by ionization. A uniformity veto rejects events whose signal is spread too evenly across the detector, quantified by a low coefficient of variation of the channel amplitudes. Incoherent baseline noise looks like this; the localized deposit of a shower core or a penetrating particle does not. An emptiness veto removes events whose total energy or hit count falls below minimal values. Finally, a “flash” veto removes events in which the signal is confined to one or two adjacent planes, which cannot correspond to a particle crossing the stack and usually points to a localized electrical disturbance. The thresholds for these conditions are collected, together with the clustering, pre-selection, tracking, and fit parameters, in Table 2 and in the released configuration file, and are deliberately loose; their role is to discard pathological events cheaply, not to shape the physics sample, which is done later through the track- and quality-based selections described below.
Table 2.
Reconstruction and selection parameters of the released configuration. The veto thresholds are deliberately loose (Section 3.2).
3.3. Track Finding and Three-Dimensional Reconstruction
Tracks are built from the clusters in two steps: a road-search finder operates separately in each projection, and the resulting two-dimensional tracks are then matched into three-dimensional ones. The finder is a classical seeded road search [19]; with at most three measurements per projection, a progressive filter would gain nothing over the direct fit below.
The road-search finder is confined to the hadron block, a choice dictated by the geometry of Section 2.1. The 22 cm lead target and the 2.2 m air gap that separate the two blocks break the trajectory of a traversing particle, so that the footprint it leaves in the gamma block does not, in general, lie on the straight line defined by its hadron-block segment. Including the gamma planes in the fit therefore does not add two well-aligned points at a long lever arm, as one might hope; it adds two systematically displaced points and imposes a large, spurious tilt on the reconstructed direction. Accordingly, the finder, with the subsequent fit, uses only the six hadron-block planes. The development-stage pipeline that included the gamma planes did show a strongly biased azimuth (Section 4.3), but it differed from the present one in the section assembly and in the alignment as well, so that comparison does not isolate the contribution of the gamma planes; the exclusion rests on the geometry of Section 2.1 rather than on a dedicated measurement.
Within the hadron block, the finder proceeds from a set of seed planes and extends each candidate upward through the plane sequence of a given projection. Starting from a seed cluster, it predicts the position in the next plane by linear extrapolation from the last one or two hits and attaches the nearest cluster lying within an adaptive search window; the window widens in proportion to the vertical gap between planes, to absorb the larger extrapolation uncertainty across the thicker absorber sections. A limited number of planes may be skipped, so that a plane that happens not to register a cluster does not terminate an otherwise good track. The seed set deliberately includes the deepest planes even though, at the analysis thresholds, they yield a usable cluster in only about a third of the events: 0.31 for plane 7 and 0.38 for plane 8 on the good-run sample, against the raw occupancies of 0.75 and 0.61 reported in Section 4.1. Clustering is the stronger condition, since the occupancy counts any above-pedestal channel, whereas a cluster must also reach the minimum summed amplitude of Table 2; both fractions vary by about between groups of runs. Unless the deepest planes may seed a track, an upward-only search never reaches them and never gets the third point that lifts a track out of the two-point regime. Candidate tracks from different seeds that share most of their clusters are merged, the longer being kept, so that one physical track is not counted several times.
Pairing the two projections into three-dimensional tracks uses the track energy as its primary criterion. A particle deposits comparable ionization in the X and Y chambers it crosses, so the two projections of one particle should carry similar total amplitude; the finder orders the tracks of each projection by energy and pairs them in rank when their energy ratio lies within a set factor, assigning any remaining tracks by a geometric criterion. For the angular analysis of Section 4.3 we use only events that yield a single track in each projection, for which the pairing is unambiguous, so that the details of the multi-track assignment do not enter those results.
A paired X and Y track are then combined into a set of three-dimensional hits and fitted with a straight line. The transverse coordinate measured by a plane is taken from its cluster centroid; the orthogonal coordinate at that depth, which the plane does not measure, is taken from the fitted line of the partner track. Cluster positions are converted from channel number to millimeters through the calibration of Section 3.4. The fit is a weighted least-squares line in which the weight of each point reflects the multiple scattering accumulated above its plane [20],
so that planes deeper in the iron, where the direction has been perturbed more, carry less weight without any assumption about the particle momentum; the two gamma planes are excluded, as explained above. The fitted slopes of the line , define the arrival direction,
with the azimuthal offset of the detector X axis from north. The orientation of the instrument has not been surveyed, and we have found no record of it that we could verify; we therefore set throughout and report every azimuth in the detector frame. This choice affects the absolute zero point of the azimuth, and through it, the right ascension in Section 4.3, but not the shape of any distribution, and it leaves the flatness statistic of Equation (5) unchanged.
The absorption pattern has one consequence that propagates into every angular result. The transverse coordinate is quantized by the 120 mm pitch, so the reconstructed slope is quantized as well. Most tracks have only two active planes per projection, and a two-point slope can take only the discrete values set by the pitch w and the lever arm mm, that is, multiples of , or 5– in angle near the vertical. A third plane does not remove the quantization but refines it considerably: the least-squares slope is then a fixed linear combination of three quantized positions, and the attainable values form a lattice whose spacing follows from the plane heights of Table 1. That spacing is in the X projection and in Y, some sixty and one hundred and twenty times finer than the two-point step. The lattice being dense, however, does not make it uniformly populated. Three hits are most often collinear on the coarse channel grid, and the least-squares slope of such a configuration falls exactly on a two-point value. The reconstructed slopes therefore still concentrate near the coarse teeth. Of the clean sample, of the projection slopes lie within a tenth of a step of a tooth, against the expected for a continuous distribution, and the median distance to the nearest tooth is 0.20 steps in the Y projection against the 0.25 of a continuous variable. That residual comb is not, however, a property of three-point tracks in general. It is carried entirely by the events in which the planes are illuminated from edge to edge (Section 4.4): within that sub-sample the fraction near a tooth is in X and in Y, and in the complementary sub-sample it is and , that is, at or below the value of a continuous distribution. Three-point tracks whose clusters are localized show no comb, and the structure in the reconstructed zenith distribution of Section 4.3 has a different origin.
The two projections differ here, and not because of the channel count: both have the same 120 mm pitch and, from plane 3 to plane 7 and from plane 4 to plane 8, the same total lever arm of 830 mm. The difference lies in the intermediate spacing. The X planes sit at 1460, 1010 and 630 mm, splitting the lever arm as 450 and 380 mm, while the Y planes sit at 1300, 820 and 470 mm, splitting it as 480 and 350 mm. The three-point lattice depends on that split, and the two projections therefore reconstruct slopes on grids that differ by a factor of two in granularity. The effect is invariant under , so it could in principle contribute to the -periodic modulation discussed in Section 4.3, though Section 4.4 shows by measurement that it does not, and it cannot contribute to a -periodic one.
Throughout this paper, we therefore distinguish the coarsely quantized two-point tracks from the more finely quantized 3 + 3 tracks, those with three active planes in each projection. The latter subset forms the basis of the angular results in Section 4.3.
3.4. Channel-to-Position Calibration and Plane Alignment
Converting a cluster centroid, expressed as a channel number, into a transverse position in millimeters is the step at which two data-driven corrections enter. The conversion is linear,
where c is the centroid, mm the channel pitch, the number of channels of plane p, and a per-plane alignment offset determined below. Each plane must be centered by its own width. The planes differ in width: 50, 69, 48 and 72 channels for the gamma-X, gamma-Y, hadron-X and hadron-Y planes. Referring them all to one common center would place their geometric centers at different physical positions and impose a width-dependent offset between planes, which the fit would read as a tilt even for a perfectly vertical track. Centering by each plane’s own width removes that artifact.
Per-width centering assumes, however, that the planes are perfectly co-aligned about a common vertical axis, and real planes are not. Determining the residual positions of detector elements from the tracks themselves is standard practice in collider tracking, where global least-squares methods such as Millepede solve for tens of thousands of alignment parameters simultaneously, with the track model carrying the multiple scattering explicitly [21,22,23]. The problem here is far smaller: six offsets, one translation per hadron-block plane, with no rotational or curvature degrees of freedom. The crossed-plane geometry, with only three measurements per projection, does not support a simultaneous fit of alignment and track parameters. We therefore use the simplest estimator that the geometry admits. Residual offsets displace the effective center of a plane by a fraction of its width. They arise from the mechanical mounting, from inactive channels that bias a centroid, and from the section assembly of Section 3.1. A constant offset in a single plane may look harmless, but because the planes are separated vertically, it tilts every track that crosses them, and the tilt accumulates over the lever arm of the stack. Left uncorrected, these per-plane offsets are the dominant systematic in the reconstructed direction. We remove them through the term in Equation (3).
The offsets are obtained from the tracks themselves through a simple physical constraint: for a cosmic-ray flux that is symmetric in azimuth, the mean transverse position of the tracks crossing a plane must coincide with the geometric center of that plane. The mean position of the reconstructed tracks in a plane therefore measures its residual offset, and each iteration updates
with the mean residual of clean penetrating tracks in that plane. The procedure converges only under two conditions. It is applied only to the clean sample of 3 + 3 tracks, those with three active planes in each projection, whose slope is the more finely quantized of the two classes (Section 3.3). A global tilt is absorbed into the straight-line fit of each individual track and is therefore invisible in the per-track residuals. The mean-position criterion pins the offsets down only when the reconstructed slope samples the angular range finely enough for the residual distribution to be sensitive to a displacement of a fraction of a channel; on the coarsely quantized two-point tracks, whose slope takes one of a handful of values, the same procedure does not converge reliably. It is also iterative and additive: the data are reconstructed with the current offsets, the mean residual position in each plane is measured and added to that plane’s offset, and the cycle is repeated. In practice a few passes suffice, and the fixed point is unambiguous: at the offsets of Table 3 the mean residual is below 0.1 mm in every hadron-block plane, and the mean reconstructed slope, which begins near with no alignment, is below in both projections. Convergence must be verified. An intermediate iteration can leave one projection aligned and the other not. In that state, the residuals of the second projection still grow linearly with depth, which is a plane rotation rather than a set of independent displacements, and such a residual tilt propagates directly into a -periodic term in the azimuth. The effect of the alignment on the azimuthal distribution is shown in Section 4.3. Offsets are obtained for all six hadron-block planes; the gamma planes, excluded from the direction fit, keep . Table 3 lists them. The offsets are effective quantities: they absorb mechanical displacement, dead-channel bias in the centroids, and any residual convention of the section assembly alike; some are sizeable (up to m in the Y planes), reflecting the combined effect of these corrections rather than a literal mechanical displacement alone. Only their combination with the geometry enters Equation (3). One condition of the procedure is stronger than it appears and is examined in Section 4.4: the mean position constrains a plane only if the centroids that enter the mean actually measure a position. In most events of the clean sample, the plane is illuminated from edge to edge, its centroid then varies by little more than one channel, and the criterion is satisfied by construction rather than by the alignment being right. The offsets of Table 3 are therefore reported as the state of the released pipeline, and Section 4.4 gives both the measurement that exposes the degeneracy and a second set derived without it.
Table 3.
Track-based alignment offsets of Equation (4) at the fixed point of the iteration, as stored in the released configuration. At these values, the mean residual of the clean sample is below 0.1 mm in every hadron-block plane, and the mean reconstructed slope is below in both projections.
Two properties of Table 3 deserve comment, because the magnitudes invite a misreading. All six offsets carry the same sign, from to mm, which a set of independent mechanical displacements would not produce. The Y planes are 72 channels wide (8.64 m) and the X planes 48 (5.76 m), and Equation (3) centers each plane on its own width, while a track sample is required to have hits in both projections and is therefore confined to the narrower X aperture. If that aperture is not concentric with the wider Y plane, the mean position of the sample in a Y plane sits off the Y geometric center by the mismatch, and the alignment absorbs it as a common-sign offset larger in Y than in X. The six offsets accordingly decompose into a constant and a term linear in the plane height, , with mm and in X and mm and in Y; the residuals about those lines are , , mm in X and , , mm in Y, so the three planes of each projection lie on a straight line to better than a tenth of a channel. The large numbers sit almost entirely in the constant, and a constant common to every plane of a projection is a translation of the coordinate origin: it tilts no track and changes no reconstructed direction. What affects directions is the linear term, and there the two projections are comparable, against ; the first is the origin of the mean reconstructed slope of about that the uncorrected reconstruction shows (Section 4.3).
The stability of the offsets between observing periods can be tested directly, since the two seasons are independent data sets. Iterating the alignment separately in each, from independent starts, both converge in a single pass to a mean residual of 0.0 mm and a mean reconstructed slope below , the clean sample dividing into 505 tracks in 2021 and 485 in 2023. Taking the 2021 value first, the offsets are and mm in plane 3, and in plane 4, and in plane 5, and in plane 6, and in plane 7, and and in plane 8. The season-to-season differences are , , , , and mm, the uncertainties being the standard errors of the mean hit position in each season; against the hypothesis of no change, they give for 6 degrees of freedom. They are, however, all of the same sign, and a single common translation of mm, less than half a channel, describes them, after which falls to 0.48 for 5 degrees of freedom. The relative, plane-to-plane alignment is therefore identical in the two seasons within the statistics, and the two differ only by a rigid shift of the illuminated pattern, which leaves every reconstructed direction unchanged.
3.5. Good-Run Selection and Integrity Audit
Reconstruction quality depends on which runs enter the analysis, so the pipeline includes a file-level integrity and good-run audit before any physics selection (Figure 2). For every daily file, it records the presence of each readout section, the fraction of events with fewer than three active Y planes, duplicate event records shared with other files, and event timestamps inconsistent with the observing season. The audit exposed a hardware failure. In 35 runs, most prominently a contiguous block in December 2021 and a group in August 2021, one DAQ branch was inactive, removing the front/back sections of three of the four Y planes. The same branch carried two middle X sections, whose loss is inconsequential because the left and right sections span the full plane; the X projection therefore survives while the Y projection cannot form a track. The audit also found 3575 events duplicated between six pairs of raw files (partial re-copies of the same days) and two files misfiled from 2022 (656 events). All flagged files, 47,612 events or 16.3% of the data set, are excluded through a configuration list; the events remain in the catalog with a bad_run status so that event identifiers are preserved. The dead-branch exclusions do not change the number of events passing the physics pre-selection, since those events lack the required Y planes, whereas the duplicate-file exclusions remove 1265 previously accepted copies. Finally, the bottom panel of Figure 2 shows a slow rise of the fewer-than-three-Y-planes fraction through spring 2023 with all sections present; this efficiency drift affects the event rate but not the per-event reconstruction, and is left uncorrected here.
Figure 2.
(Color online.) Run-by-run data quality over the 2021 and 2023 seasons; each point is one raw data file (one run). (Top): minimum presence among the Y-projection readout sections, i.e., the fraction of events in the run in which the least active Y section is recorded at all; values near zero signal an inactive readout branch. (Bottom): fraction of events in the run with fewer than three active Y planes, the minimum for a Y-projection track. Open orange markers are the runs excluded by the good-run selection, including the December 2021 block of dead-camera runs; excluded events remain in the catalog with their status flagged. A slow drift of the Y-plane efficiency is visible through spring 2023 (bottom right); it affects rates only and is left uncorrected here.
The criterion looks at section presence and at Y-row multiplicity, and it does not look at the digitizer. It should. Over the 263 runs, the median run has 0.015% of its gamma-block cells at the 4095-count ceiling, but 63 runs exceed 1% and those runs carry 93% of all clipped cells; 25 runs exceed 5%. The worst of them, a run of 9714 events, contributes a sixth of all the clipped cells in the data set and passes the present good-run selection intact. Section 4.2 measures what that does to an amplitude-weighted quantity.
The same pass exposes a second run-level state that the criterion does not see. The median run has a median summed calorimeter amplitude of ADC counts; seventeen runs, 14,291 events or 4.9% of the data set, have a median above , and the worst of them, a median of with two of the 30 trigger counters responding and 16% of its gamma cells clipped. A factor of eighty in the median deposit between runs is not a property of the flux, and those runs also carry the clipping. Two quantities that a single pass over the raw text computes without any reconstruction, the median calorimeter sum and the fraction of cells at the digitizer ceiling, would separate them; adding both to the criterion is a change for the next release rather than a re-analysis of this one, and we quote the affected fraction so that the reader can judge its weight.
3.6. Implementation
The pipeline is written in Python on the standard scientific stack: NumPy [24] for the array operations, SciPy [25] for the assignment problem of the projection matching, Matplotlib [26] for the figures, and Astropy [27,28] for the equatorial conversion. The results reported here were produced with Python 3.14.5, NumPy 2.4.6, SciPy 1.17.1, Matplotlib 3.10.9 and Astropy 7.2.0. It processes the full data set in a single streaming pass over the raw files, building the event catalog, applying the veto and quality classification, and reconstructing tracks without holding the entire data set in memory. This matters in practice, because deriving the calibrations requires reprocessing the data many times: on a laptop-class machine the reconstruction of the 86,433 quality-selected events runs in about 85 s on a single core, of order events per second, and the catalog-building pass over the full data set is run with four worker processes. Either is fast enough to iterate the alignment to convergence in an afternoon. Each stage is an independent, documented module, and the diagnostic scripts used to measure the occupancy, the plane offsets and the track quality are released together with the pipeline (see the Data Availability statement), so that every calibration reported here can be reproduced and, should the detector change, re-derived.
3.7. Event Selection Summary
Table 4 summarizes the selection. The pre-selection applied while building the catalog requires a minimum total deposition of 500 ADC counts, at least three active planes among the four planes of each projection, enough to test a projected track against a residual, and signal in the bottom pair of planes; together with the good-run and integrity flags, it retains 164,227 events (56.4%).
Table 4.
Event selection cut flow. Percentages refer to all recorded events. The pre-selection requires a minimum total deposition, at least three active planes in each projection, and signal in the bottom pair of planes; it also removes the 47,612 events (16.3%) flagged by the good-run and integrity audit (inactive Y-readout branch; 3575 duplicate events in six file pairs; 656 events in two misfiled 2022 runs). The clean angular sample additionally requires a single reconstructed track with three active planes in each projection.
The 127,131 rejected events are divide unevenly, and the division is informative. The requirement of signal in the bottom plane pair is the largest single cut, removing 48,181 events (16.5%); the good-run and integrity flags remove 47,612 (16.3%); the requirement of three active Y planes removes 29,893 (10.3%) and that of three active X planes 1444 (0.5%). These counts are exclusive: each rejected event is attributed to the first cut it fails. On that account, the deposition threshold is responsible for a single event, so the 500-ADC threshold is inert at the trigger rates of this instrument. It is retained in the configuration for completeness, but it selects nothing, and no result in this paper depends on it. The twenty-fold asymmetry between the Y and X plane requirements is an independent measure of the per-projection efficiency difference quantified in Section 4.1, obtained from the event counts rather than from the occupancy.
The bottom-pair requirement is not a neutral cut. It selects events whose cascade reaches the deepest planes and therefore biases the pre-selected sample towards the events that deposit most. That bias propagates to everything downstream of the pre-selection, including the clean angular sample of Section 4.3. It does not affect the longitudinal and transverse response of Section 4.1 and Section 4.2, which are measured on the good-run sample before any pre-selection is applied. Vetoed events (Section 3.2) are then removed, and the remaining events are gated by a composite quality score built from the veto flags, track multiplicity and penetration, and fit residuals; the score and its weights are heuristic and are listed in the released configuration, where they can be changed without editing the source. Section S1 of the Supplementary Material measures how much the results depend on them: the number of admitted events moves by a quarter across thirteen reasonable variations of the thresholds and weights, and in eleven of them the clean sample is the same 990 events with every angular number unchanged, because within that sample four of the five terms of the score are constants. What the angular results are sensitive to is not the score but the plane illumination of Section 4.4, which moves the flatness statistic from 16.4 to 2.0. Events at or above the GOOD grade (86,433) enter the reconstruction, 65,609 of them yield at least one three-dimensional track, and 990 form the clean angular sample of Section 4.3: a single reconstructed track with three active planes in each projection. That sample is not what its name suggests. Its median event deposit is ADC counts against for two-point tracks, and in most of its events the planes are illuminated from edge to edge at – counts per channel, five to thirty times the per-channel charge of the planes in which the cluster is a single channel. It is a sample of large showers, not of penetrating single particles, and Section 4.4 shows what that does to the reconstructed direction. The particle-type labels produced by the prototype classifier are not used in this paper (Section 5).
4. Detector-Response Characterization
With the pipeline in place, we characterize the response of the calorimeter along the three axes its science program calls for: the longitudinal development of the signal with depth, its transverse spread, and the angular distribution of reconstructed tracks. In each case, the behavior to be expected is known in broad terms, and we use that knowledge as a test. A longitudinal curve that falls smoothly with depth, a lateral profile concentrated near the axis, and an azimuthal distribution consistent with isotropy are the signatures of a reconstruction that is working. The measurements in this section are made on the good-run sample of Section 3.5, which the nominal software threshold does not reduce further; where a single clean sample of tracks is required, in Section 4.3, this is stated explicitly.
4.1. Longitudinal Development
The longitudinal behavior of the calorimeter is summarized by two quantities as a function of depth: the occupancy of each plane, that is, the fraction of events in which it carries a signal, and the mean ionization it records. Depth is expressed in cumulative nuclear interaction lengths, computed for each plane from the thickness and composition of the absorber above it (Table 1), and runs from at the top gamma plane to at the lowest active plane. The two projections are shown separately in Figure 3.
Figure 3.
(Color online.) Longitudinal development in the calorimeter for the full good-run sample (). (Top): plane occupancy (fraction of events with signal in the plane) versus cumulative nuclear interaction length ; X and Y planes are drawn separately to expose the per-projection efficiency offset, and error bars are Wilson intervals. (Bottom): mean energy deposition per channel (ADC, arbitrary units); normalizing by the number of channels (48–72 per plane) makes the X and Y planes directly comparable. The average includes events with no signal in the plane. The shaded band marks the material between the gamma and hadron blocks: the 220 mm lead target, the 2.2 m air gap, the 130 mm lead hadron converter, and the first 100 mm iron layer.
The profiles use the full good-run sample of 243,746 events, of which the nominal 500-ADC offline threshold removes two, leaving 243,744; the threshold is therefore inactive in practice, and the profiles characterize the recorded event population itself. The occupancy (Figure 3, top; Table 5) falls along the stack from unity at the gamma block to and in the two deep X planes, and to , and in the Y planes. Occupancy is a binomial fraction, and the uncertainties quoted for it are 68% Wilson intervals [29,30]: they stay inside and keep a finite width at the gamma planes, where the occupancy is unity and the normal interval would vanish. The two deepest Y planes are equal within these intervals, their difference being . Plotted against the cumulative interaction length, each projection falls monotonically, but the X and Y curves are offset so strongly that deeper X planes have higher occupancy than shallower Y planes. Plane 5 at registers 0.900 against 0.856 for plane 4 at , and plane 7 at registers 0.747 against 0.612 for plane 6 at . This is a per-projection efficiency offset of the detector, not absorption, at least as measured at this threshold. The event selection gives the same conclusion far more sharply: of the events failing the requirement of three active planes in a projection, 29,893 fail it in Y against 1444 in X, a factor of twenty (Section 3.7).
Table 5.
Longitudinal response of the eight active planes on the good-run sample (, the full good-run data set). Occupancy is the fraction of events with any above-pedestal signal in the plane, with 68% Wilson intervals; the mean deposition per channel is taken over all events (ADC counts; events without signal in the plane enter as zero), and the last column conditions it on the plane having fired. Conditioned on firing, all planes fall in a common 237–332 ADC band: the entire difference between the projections in the unconditional means originates in the occupancy.
Both statements are made at the amplitude that defines an active plane, and both move with it. Table 6 shows that the ordering is not preserved. At 5 counts plane 7 registers 0.747 against 0.612 for the shallower plane 6; at 30 counts it registers 0.362 against 0.445, so the deeper X plane falls below the shallower Y plane, which is what absorption alone would give. The comparison between planes 5 and 4 keeps its sign at 30 counts, 0.745 against 0.662, but reverses as well, to 0.609 against 0.662, once the per-channel pedestals of Section 3.2 are subtracted. The twentyfold asymmetry of the event selection uses the same 5-count definition of an active plane and carries the same dependence. We therefore put the result no more strongly than it stands. At the working threshold the X planes are active in more events than Y planes lying above them, and no absorption can produce that; but the size of the difference, and for the deepest pair its sign, depend on the amplitude above which a channel is counted, so what is established is a property of the instrument together with its readout rather than a threshold-independent difference in efficiency. One candidate follows from the assembly of Section 3.1: a hadron-block X plane sums three overlapping sections against two for a Y plane, so an X channel carries one more section’s baseline. We have not measured that, and a per-projection calibration of the chamber response remains the step this comparison calls for.
Table 6.
Plane occupancy on the full good-run sample () against the amplitude at which a channel is counted as a hit, together with the fraction of events in which the plane yields a cluster the track finder can use. The first column, at the working value of 5 ADC counts, is the occupancy of Table 5 and of Figure 3. The last column adds the cluster conditions of Section 3.2, a channel above 30 counts and a summed amplitude of at least 50, and therefore lies a little below the ≥30 column. Occupancy is not a threshold-independent property of a plane: across the hadron block it falls by 15.5 to 38.5 percentage points between 5 and 30 counts.
The mean energy deposition must be compared per channel, because the planes carry between 48 and 72 channels: the raw per-plane sums differ between neighboring X and Y planes by factors of 1.42–1.43, almost exactly the channel-count ratios (1.38 and 1.50), and the apparent excess of the gamma block disappears once normalized. Per channel (Figure 3, bottom), the X planes are uniform, 237–248 ADC at every depth from to , while the Y planes fall from 249 and 223 in the upper stack to 149 and 157 in the two deepest planes, mirroring the occupancy offset of the same projection. The average includes events without signal in the plane, so it convolves per-event deposition with plane efficiency; the larger uncertainties of the deepest planes reflect the heavy-tailed deposition of the rare showers that reach them. Table 5 lists the per-plane values; conditioned on the plane having fired, all eight planes fall in a common 237–332 ADC band, so the entire difference between the projections in the unconditional means originates in the occupancy. A per-projection calibration of the chamber response, beyond the scope of this paper, is the natural next step suggested by this comparison.
This measurement has a place in the instrument’s history. The shape of the ionization curve through a thick calorimeter, and in particular its rate of decline, is the observable in which the Tien Shan effect was reported at this station with the earlier lead calorimeter [1,2]. That effect is the anomalously slow absorption of the hadronic component of high-energy EAS cores, together with an excess of events depositing a large ionization in the lower layers. The present measurement is not that effect. It is the baseline longitudinal response of the calorimeter to the ordinary cosmic-ray flux, measured with a transparent and reproducible procedure. It is, however, the same class of observable, obtained with the same instrument, and the pipeline described in this paper is what makes it possible to select high-energy cores and to study the energy dependence of their absorption on a modern footing. We return to that continuation in Section 5.
4.2. Transverse Profile
The transverse profile measures how the recorded ionization is distributed about the axis of the deposit. For each plane, the axis is taken as the position of the peak channel, refined by the amplitude-weighted centroid in a narrow window around it, and the above-pedestal amplitude is accumulated as a function of distance from that axis; averaging over events gives the lateral profile of Figure 4. This peak-referenced definition is deliberate. Defining the axis instead by the centroid of the whole plane fails for shower events, in which several clusters and residual noise spread across the plane pull the whole-plane centroid away from the core and inflate the apparent width to the scale of the detector itself. Referencing the profile to the peak, with a pedestal threshold that suppresses the low-level noise at large radius, gives a stable measure of the width.
Figure 4.
(Color online.) Transverse profile of the recorded signal: the fraction of the total above-pedestal amplitude (ADC counts) in each one-pitch (120 mm) bin of lateral distance from the cascade axis, defined per plane as the amplitude-weighted centroid in a -channel window around the peak (, the full good-run sample; each curve is normalized to unit sum, so only shapes are compared). The profile is one-dimensional in the coordinate measured by the plane, and the one-pitch binning avoids aliasing between the channel pitch and the bin width. (Left): X versus Y planes (axial symmetry). (Right): gamma versus hadron block; RMS and widths are given in the legends. Positions near the plane edges cannot contribute at large r, which slightly steepens the tails.
The profile needs two clarifications. The axis so defined is the axis of the cascade recorded in the calorimeter: without the surrounding shower array, the position of the EAS core relative to the detector is not known, so the peak may be the core itself or a local high-energy deposit, and no statement about the true shower axis is implied. The vertical scale, in turn, is dimensionless: each curve is the fraction of its group’s total above-pedestal amplitude per 120 mm bin, normalized to unit sum. The curves give an empirical one-dimensional lateral distribution of the recorded signal in ADC counts, with no conversion to an energy density in physical units.
The profile is histogrammed in one-pitch (120 mm) bins, since finer binning aliases against the channel pitch and imprints a sawtooth on the distribution. So binned, the two projections give RMS widths of and m and of and m for the X and Y planes, respectively (Figure 4, left). The uncertainties here and below are standard errors over sixteen independent blocks of runs [31], so they carry the run-to-run variation as well as the counting statistics. The two projections therefore differ by m in RMS, that is, by standard deviations. The difference is small in absolute terms but not consistent with zero, and it is of the same sign and order as the per-projection effects of Section 4.1. The gamma block resolves a distinctly narrower deposition than the hadron block (Figure 4, right): of its signal falls in the innermost bin against in the hadron block, with RMS widths of against m, a difference of m or standard deviations. One systematic acts on this comparison and is worth quantifying, because it acts on the gamma block alone and in a known direction. The profile is an amplitude sum over events, and the gamma block clips: of its cells sit at the 4095-count ceiling against in the hadron block (Section 3.5). Clipping removes charge from the peak channels, which are the ones nearest the axis, so it widens the measured profile. Of the good-run events, have at least one clipped gamma channel and those events carry of the total gamma-block amplitude; removing them moves the gamma RMS from to m while the hadron RMS moves only from to m, so the separation grows from to m. The published number is therefore an upper limit on the gamma-block width and the ordering reported here is conservative. Work in progress on the same instrument reaches the gamma block from the opposite direction, comparing the measured layer-by-layer deposition with simulated cascades, and attributes an excess in the first row to saturation of the chambers there [32]. Two independent routes therefore identify the same defect. We quote m as the measurement, because removing half the amplitude is not a small selection and the clipped events are physical showers rather than artifacts, and m as the bound that the unclipped part of the sample gives. These events are separately flagged by the saturation veto of Section 3.2 and so are absent from the tracking of Section 4.3; they are present here because the response of Section 4.1 and Section 4.2 is deliberately measured before the vetoes. The 120 mm pitch still limits how much of the electromagnetic core is resolved, since true electromagnetic shower radii at these energies are comparable to a single cell. The ordering expected from shower physics is nevertheless recovered once the aliasing is removed. In both blocks 90% of the recorded signal lies within – m of the cascade axis. That is comfortably inside the half-widths of m (X) and m (Y) over which a plane can record signal, so lateral leakage is negligible for contained events. The slight narrowing of the deepest planes reflects the collimated subsample that reaches them, together with the edge truncation noted in the caption.
The design anticipates this ordering. The granularity of about 10 cm [5] was chosen to locate a core and to trace its development in depth, not to resolve the fine transverse structure of an electromagnetic shower, whose Molière scale in lead is an order of magnitude below the cell size. The transverse profile should therefore be read for what it robustly establishes: that the recorded signal is concentrated within about 1.2 m of the cascade axis, and that the gamma block is measurably the narrower of the two. It is not a measurement of the intrinsic shower width, which would require a finer sampling than the calorimeter provides. This comparison is nonetheless the one the core-physics program relies on: studies of anomalous absorption and coplanarity read events through the relative behavior of the electromagnetic and hadronic deposits, and the present measurement establishes its baseline.
4.3. Angular Distribution
The angular distribution of the reconstructed tracks is where the pipeline is tested most directly, because the expected behavior is known in advance: the arrival directions of cosmic rays at this depth are, to a good approximation, isotropic in azimuth [33] and follow a smooth zenith dependence, and any large departure from that points to a flaw in the reconstruction rather than to a property of the sky. As noted in Section 2.1, the possibility of determining arrival directions from the calorimeter’s own layers, independently of the scintillator timing, was identified when the instrument was built [5]. The results here are based on the sample of tracks with three active planes in each projection, 990 of them in the good-run data (Table 4).
The zenith distribution of the clean sample (Figure 5a) rises steeply from the vertical, peaks in the 12– bin, and falls to the geometric cut-off at , with a median of . Neither the peak nor the median is a property of the flux. Both are produced by the events in which at least one plane is illuminated from edge to edge, which are characterized in Section 4.4: they are 791 of the 990, their median zenith angle is against for the rest of the sample, and they supply 236 of the 264 events in the 12– bin. Two instrumental effects shape the distribution. First, the reconstructed slopes are quantized, coarsely for two-point tracks and more finely for 3 + 3 tracks (Section 3.3): the elementary two-point step is one pitch over the m lever arm of each projection, in slope or 5– in angle near the vertical, and the three-point fit subdivides it. The positions are marked in the figure. In the sample as a whole the 12– bin holds 264 events against a mean of 108 in the two adjacent bins, an excess of a factor of that coincides with the tooth at , and the fraction of tracks whose total slope lies within a tenth of a step of a tooth is against the of a continuous distribution. Both signatures are carried by the edge-to-edge sub-sample: once it is removed, the excess falls to a factor of and that tooth fraction to , so the comb of Section 3.3 is not in fact resolved in three-point tracks, and what Figure 5a shows at small zenith angles is the centroid effect of Section 4.4 rather than the slope lattice. Second, the geometric acceptance of the narrow, tall stack falls continuously with inclination, not only beyond . We therefore quote the peak position and the median as descriptors of the sample and not as a measurement of the flux, and we do not compare the raw histogram with the shape of the atmospheric muon flux [34,35]: the sample is not a muon sample, as the deposits quoted in Section 3.7 show, and its parent population is the shower flux that triggers the station. The comparison that can be made is with a detector-level simulation at the observed conditions, and it is given in Section 4.4.
Figure 5.
(Color online.) Angular reconstruction on the clean sample of single tracks with three active planes in each projection (). Throughout, localized clusters denotes the events in which no plane is lit from edge to edge (Section 4.4). (a) Zenith-angle distribution in bins, split into the 791 events in which at least one plane is lit edge to edge and the 199 in which none is. The peak in the 12– bin belongs almost entirely to the former: it is produced by centroids that report the illuminated aperture rather than the particle, and the shape of the total histogram is therefore not a measurement of the zenith distribution of the flux. Dotted vertical lines mark the teeth of the two-point slope comb at for to 5, with mm and mm; the localized sub-sample shows no excess at them. (b) Azimuthal distribution with the isotropic expectation (dashed) and the first-plus-second-harmonic fit of Equation (6) (solid), which quantifies the residual instrumental modulation; the points with Poisson errors are the localized sub-sample, scaled to the same area, and are compatible with uniformity. (c) of the azimuth distribution against uniformity for single tracks by track class, from two-point (coarsely quantized) to 3 + 3 tracks, followed by three points after the illumination cut: the localized sub-sample under the published alignment, the same sub-sample after the alignment of Equation (4) is re-derived on it, and the half of it that was held out of that re-derivation; the open marker shows the level of the uncorrected development-stage pipeline, and the dotted line the value expected for an isotropic sample. The classes differ in size, so the progression indicates a trend rather than a comparison at fixed statistics.
Azimuthal uniformity provides the sharpest end-to-end test, because an isotropic flux must reconstruct flat in regardless of acceptance. One objection must be met first. The plane alignment of Section 3.4 is itself derived from an isotropy argument, in which the mean transverse position of the tracks crossing a plane is required to coincide with its geometric center, so validating the reconstruction by azimuthal uniformity could be circular.
The two procedures use different observables. The six offsets come from a single scalar per plane, the mean hit position; the azimuthal distribution is never evaluated, let alone minimized, during the alignment, so its subsequent flatness is a prediction that could have failed. That the modulation instead falls by close to two orders of magnitude, from to , is a non-trivial consistency result, although the two figures are not like-for-like: the uncorrected pipeline yielded a smaller clean sample, so the ratio should be read to an order of magnitude. This argument for independence is correct as far as it goes and still incomplete. Section 4.4 shows that the two observables, although distinct, are linked through a population of events whose centroid carries no position information, and that the link accounts for the residual modulation measured below. The reader should take the paragraph above as the reason the test is not trivially circular, not as a demonstration that the alignment and the flatness are independent.
Two caveats remain. The test assumes an isotropic flux, so what it checks is the reconstruction, and it says nothing about the sky. Independence from the alignment, argued above, and independence from that assumption are separate questions. Neither is settled here: Section 4.4 shows that the first fails in a specific and measurable way. The test is also sensitive only to what the alignment does not fix: a systematic shared by both projections and symmetric in azimuth would leave the statistic untouched.
We quantify flatness with
over bins. For the uncorrected development-stage pipeline, with raw section assembly, gamma planes in the fit and no alignment, single tracks gave . With the corrected assembly, deep-plane seeding, and the alignment of Equation (4), the statistic falls to 899 for two-point tracks (), 162 for 3 + 2 tracks (), and for the clean 3 + 3 sample () (Figure 5c). The distribution is therefore not yet compatible with perfect uniformity. For an isotropic sample the statistic has expectation and standard deviation , so a single realization scatters about unity rather than attaining it; the observed 15.8 lies far outside that scatter. The residual, nevertheless, falls by close to two orders of magnitude relative to the uncorrected pipeline, and it drops sharply as measurement points are added. The remaining modulation of the clean sample is characterized by the harmonic fit
which gives toward and with axis (Figure 5b). The uncertainties are bootstrap estimates over the events of the sample. These amplitudes must be read against the level that counting statistics alone produce, a point long established for harmonic analysis of directional data [36]: for an isotropic sample of 990 events the least-squares estimator returns for either harmonic, with a 95th percentile of . The second harmonic is far above that floor, with a probability below of arising by chance; the first sits at the floor, with , and is therefore at most marginally present in the combined sample.
Splitting the sample by observing the season separates the two components sharply. The second harmonic is reproduced in both seasons at the same amplitude, in 2021 against in 2023, a difference of , and is significant in each ( and ). Its axis moves from to , a shift of that is consistent with the two being the same to about two standard deviations. The first harmonic is also significant within each season, and at a comparable amplitude, in 2021 against in 2023; but its direction is not reproduced, against . The two nearly oppose one another and largely cancel when the seasons are combined, which is why the combined amplitude drops to the statistical floor.
The shape of the residual is that of directions piled along the detector axes. Of the 990 events, 276 lie within of , , or , against the 110 that uniformity would give, and 198 have a reconstructed slope compatible with zero in one projection, or , which pins the azimuth to an axis exactly. A four-fold term is correspondingly strong: fitting in addition to Equation (6) gives with axis , larger than the second harmonic, which is why the two-harmonic fit of Equation (6) still leaves on 31 degrees of freedom against its own fitted curve. We first attributed the zero slopes to the slope lattice. That is not their origin: both the zero slopes and the four-fold term are produced by the plane illumination, and Section 4.4 identifies the mechanism and removes it. Of the 198 events with a vanishing slope, 188 are events in which all three X planes are lit from edge to edge, and 190 have at least one plane lit that way.
The first harmonic admits no such explanation. A modulation of the plane illumination is symmetric under and cannot generate a -periodic term at all. A residual mean slope left by an incomplete alignment would do so, and is the natural suspect, but on the sample as a whole it is excluded by direct measurement: within each season the mean reconstructed slope is consistent with zero, and in 2021, and in 2023, and the directions of these residual tilts do not coincide with the measured of either season. The suspect is nevertheless correct, and the reason the test missed it is the same illumination effect: the mean slope of the full sample is held at zero by the very events whose slope carries no information. On the sub-sample in which no plane is lit from edge to edge, the mean slope is not zero, and , which by Equation (2) points to ; the first harmonic measured on that sub-sample is toward . The agreement to identifies the first harmonic as residual misalignment, and Section 4.4 shows that it disappears when the alignment is re-derived on that sub-sample. The apparent season dependence of in the full sample follows from the season dependence of the illumination mixture: the properly illuminated events are 30% of the 2021 sample and 9% of the 2023 one.
On the statistics of the clean sample ( per bin) these harmonics correspond to bin-to-bin variations of order the mean, so the azimuth is not yet a precision observable. It is, however, empirically parameterized, and Figure 5c shows that it is a direct monitor of reconstruction quality.
Because the detector sits on a mountain, we checked whether the local terrain contributes to the azimuthal distribution. The station is on the Zhusaly-Kezen pass, flanked by peaks that rise to elevation angles of about and to the north and south. The reconstructed sample is confined to zenith angles below , that is, elevations above , so a ridge obstructing the sky below cannot shadow it. The detector axes happen to lie close to the north–south line of the peaks, but the elevation argument settles the question: the residual azimuthal structure is instrumental.
The pipeline also converts the reconstructed local directions and the event timestamps to right ascension and declination with Astropy [27,28]; the submitted version showed the resulting equatorial map. We have removed it. With the directions of four fifths of the sample set by the illuminated aperture rather than by the particle (Section 4.4), such a map displays the instrument’s field of view and its exposure and nothing else, and the absolute right-ascension zero point is in any case provisional, since the azimuthal orientation of the detector relative to north has not been surveyed. The conversion remains part of the released code.
4.4. Plane Illumination and the Limits of the Centroid
The direction of a track is a least-squares fit to the amplitude-weighted centroids of its clusters, so it measures a direction only if each cluster is localized within its plane. That premise fails for the clean 3 + 3 sample, and testing it explains every feature of Section 4.3 left above to instrumental effects of unidentified size.
Table 7 gives the measurement. In each of the three X planes, the median cluster spans all 48 channels of the plane, that is, the entire plane is above the 30-count cluster threshold, and it does so in 73 to 79% of the events; in the Y planes, which are 72 channels wide, the median cluster spans 66 to 71 channels and 45 to 51% of the planes are lit from edge to edge. These planes have no core: the amplitude within three channels of the peak is only 1.10 to 1.54 times what a perfectly uniform illumination of the same width would deposit there. The charge is that of a large shower and not of a stray signal: 1.6 to counts per channel across the full width, against 109 to 302 in the planes whose cluster is one or two channels wide, that is, the planes a single particle crossed. The comparison needs no absolute energy scale and none is claimed. The instrument is not being crossed by a particle; it is being flooded by a cascade wider than itself.
Table 7.
Plane illumination in the clean 3 + 3 sample (). A cluster is a run of adjacent channels above 30 ADC counts, so a median size equal to the channel count of the plane means that the whole plane is above the threshold. Core is the fraction of the cluster amplitude within three channels of its peak, divided by the value a perfectly uniform illumination of the same width would give; 1.00 means no core at all. It is quoted for the planes that are lit edge to edge, the ones the column before it counts; the two columns that follow give the same separation explicitly. The centroid spread is the standard deviation of the reconstructed position over the sample, quoted separately for the planes that are lit edge to edge and for the rest, and it is what the direction fit has to work with. The last two columns give the median amplitude per channel inside the cluster.
The consequence for the centroid is before the two last columns of Table 7. Where the plane is lit end to end, the centroid moves by 1.2 to 2.3 channels over the whole sample, against 11 to 18 channels where the cluster is localized. A truncated lateral distribution reports the illuminated aperture, not the particle, and reports the same aperture event after event; three such centroids are nearly collinear whatever the arrival direction, so the fitted slope collapses: the median is 0.08 for the 713 events whose three X planes are all lit end to end against 0.39 for the rest, and one fifth of them return , which by Equation (2) places the azimuth exactly on a detector axis.
This closes a circle with the alignment of Section 3.4, whose offsets are fixed by requiring the mean measured position in each plane to vanish. When most of the sample reports the same fixed centroid in each plane, that requirement maps those centroids onto a common horizontal line: with the published offsets, the mean position of the edge-to-edge events is , and mm in planes 3, 5 and 7, three numbers that agree to within a sixth of a channel, so the line through them has slope and the whole population sits within about a degree of the vertical. The zero-slope population is therefore created by the alignment, and the four-fold azimuthal structure follows from it. The objection Section 4.3 raises against itself and dismisses it as correct, though not by the route considered there: the two observables are different, but they are linked through a population whose centroid carries no position information.
The test is direct. We remove every event in which any plane is lit from edge to edge, which leaves 199 of the 990, take one additive iteration of Equation (4) on that sub-sample alone, and repeat the whole reconstruction. One part of the outcome is guaranteed in advance and we say so before quoting it: forcing the mean position to zero in every plane forces the mean slope of the fitting sample to zero, and the first harmonic is the leading order of the direction of the mean slope, so must fall. The exercise was therefore also repeated on one half of the sub-sample, chosen by event number, with the flatness quoted for the other half, which the alignment never saw. Table 8 collects all of it. Under the published alignment, the properly illuminated sub-sample already gives against the 15.77 of the full sample, with no refitting of anything; re-deriving the alignment on it gives 1.31 on 190 events, and the held-out half gives on 93. The first harmonic falls to the counting-statistics floor, which is the part that is not evidence; the second, against a floor of 0.128, is times the floor and below the 95th percentile of 0.25 at that sample size, so it is neither established nor excluded. What can be said is that the azimuthal distribution of that sub-sample is compatible with uniformity where that of the full sample is not, and that the chain 15.77, 2.00, 1.18 contains one step that involves no fitting and one that is measured out of sample.
Table 8.
Azimuthal flatness of the clean 3 + 3 sample by illumination class. is Equation (5) over bins, expectation 1 with standard deviation 0.24. The harmonics are the fit of Equation (6) with bootstrap uncertainties. The last column is the amplitude that counting statistics alone return for an isotropic sample of the same size [36]. Localized denotes the events in which no plane is lit from edge to edge; the last two rows split those events in half, deriving the alignment on one half and measuring the other, which the alignment has never seen. The two halves hold 100 and 99 of the 199 events; 93 of each still reconstruct as clean 3 + 3 tracks under the re-derived offsets, the same attrition that takes 199 events to 190 in the row above. Re-derived alignment means one additive iteration of Equation (4) taken on the properly illuminated events only, after which the whole reconstruction was repeated; the sample size changes slightly because the selection itself depends on the fit.
The third row of the table shows the mechanism from the other side. Under the re-derived offsets the edge-to-edge events no longer return zero slope but a common non-zero one, and , so instead of four axial peaks, they give a single peak at , exactly the direction those slopes define; over the whole re-aligned sample, which they dominate, that reads as and . No choice of offsets makes these events behave; they can only be removed.
The slope comb behaves the same way: the fraction of tracks within a tenth of a step of a tooth is 0.31 in X and 0.30 in Y among the events with a plane-lit edge-to-edge and 0.18 and 0.23 among the rest, against the 0.20 of a continuous distribution, and the factor of 2.4 excess in the 12– zenith bin falls to 1.3. What Section 3.3 predicts for three-point tracks, a lattice too dense to resolve, is what the properly illuminated sub-sample shows.
The sub-sample also admits the comparison with a simulation that the sample as a whole does not. A detector-level Monte Carlo, described in the Supplementary Material, generates straight tracks isotropic in azimuth with a parent, digitizes the transverse coordinate through the inverse of Equation (3) at the measured plane positions, carries per-channel efficiencies measured on the data by tag and probe, and passes the synthetic records through the same four reconstruction calls; the geometric acceptance of the stack is 124 m2 sr for . The parent index is fixed by the median reconstructed zenith angle alone, so the azimuth is a prediction. Matching the properly illuminated sub-sample requires , a value consistent with a shower-triggered population, whereas matching the full sample would require , which nothing physical produces; and with the simulation returns scaled to the size of the data sample against the 1.18 measured out-of-sample, with and . The modulation that the geometry and the measured efficiencies predict is therefore below the statistical floor of a sample of this size. The one number not compatible with it is the second harmonic, in the data against 0.043 in the simulation, a difference that is not significant at this sample size.
Two limits should be stated plainly. The sub-sample is 199 events of 990, so its harmonic uncertainties are twice those of the full sample, and 153 of them come from 2021: the illumination mixture itself changes between seasons, and that is what makes appear season-dependent in Section 4.3. The re-derived offsets rest on those same events, with standard errors of 107 mm in X and 185 mm in Y, so we do not propose them as the alignment of the instrument; we report them because repeating the reconstruction with them is the test that identifies the mechanism, and both sets are released in the configuration. The cure is a selection that requires a localized cluster before a plane enters the direction fit, with an alignment derived under that selection, and implementing it needs more data than the two seasons analyzed here.
4.5. Simulated Response to Single Particles
Everything measured above is the response to air-shower cores, mixtures of species arriving together, so it cannot say what the calorimeter does with a proton as opposed to a muon. That separation requires a simulation, and one has been carried out for this revision with Geant4 [37]: five species—protons, neutrons, muons, electrons and alpha particles—run independently, 1000 events each, at the same initial kinetic energy of 100 GeV, incident vertically at a fixed point inside the active area, with the energy deposited in each of the nine chamber rows recorded. Figure 6 gives the mean profile of each species normalized to its own total, .
Figure 6.
(Color online.)Simulated response of the calorimeter to single particles of five species, 1000 Geant4 events each at 100 GeV initial kinetic energy, incident vertically at a fixed point. (a) Mean energy deposited per chamber row, normalized to the total of that species over the nine rows; rows 1 and 2 are the gamma block, rows 3–9 are the hadron block. Row 9 is shaded: the simulation carries the full mechanical stack, but that row is not connected to the readout and contributes to no measurement in this paper. The quantity plotted is deposited energy, whereas the measured profile of Figure 3 is in ADC counts, so the two are comparable in shape and not in scale. (b) Total deposited energy event by event, each histogram normalized to the events of its own species, with equal-width bins in . The dotted lines mark the two thresholds at which the three classes part company, and the percentages are the best accuracy a single cut on this one variable reaches; within the hadron class no cut does better than chance.
Panel (a) separates the species by shape. For 100 GeV electrons 44.3% of the deposit falls in row 1 and 55.6% in row 2, and less than 0.02% of the total reaches rows 3 to 9: the electromagnetic cascade is contained by the gamma block and the 220 mm lead target beneath it. The maximum falls in row 2 rather than row 1, which is consistent with the depth scale of Table 1, those rows lying at 5.3 and 8.0 radiation lengths against a shower maximum near 9 at this energy. Muons deposit between 9.6 and 12.0% in every row, the reference against which a single-particle track in the data should be read. The profile is flatter than those figures suggest: the per-row medians of the event-by-event deposit agree to 4%, and the rise of the means with depth is the growing hard tail of delta rays and bremsstrahlung accompanying the muon, not a change in the ionization itself. The hadrons are broader and reach into the hadron block: the proton peaks in row 3 at 20.8%, the neutron one row earlier at 23.0%, and the alpha in row 2 at 26.2% and falls fastest of the three, 1.2% against the proton’s 2.4% by row 9. That ordering is what superposition gives, since 100 GeV of alpha is 25 GeV per nucleon, so its cascade develops earlier and dies sooner.
Panel (b) is what decides whether the shapes are of any use for telling one particle from another, and it answers in two parts. Across the three classes, the total deposit alone is nearly sufficient: MeV for electrons, , and MeV for protons, neutrons and alphas, and MeV for muons, where the quoted spreads are event-to-event standard deviations and not errors on the means. A single threshold on that one number distinguishes electrons from muons in every event of the sample, electrons from any hadron in 98.2 to 98.6% of events, and muons from any hadron in 97.2 to 98.5%. Within the hadron class it does nothing at all: the best single cut separates protons from neutrons in 52.3% of events, protons from alphas in 52.8% and neutrons from alphas in 51.6%, against the 50% that guessing returns. The mean profiles of the three hadron species differ, in other words, while their event-by-event distributions of total deposit do not.
One limit goes with the figure and should be read before its numbers are used elsewhere. The particles are single and normally incident at one energy, not shower cores, so the curves are not a prediction of Figure 3 and are not offered as one. What the figure supports is the separation of electromagnetic, hadronic and penetrating components, which is the distinction the two-tier design of this instrument was built to make; it does not support identification of a hadron species, and the prototype classifier carried in the released code, which attempts exactly that, remains unused for any result in this paper.
5. Discussion and Limitations
The results of Section 4 establish that the pipeline reconstructs the calorimeter’s response sensibly across all three of the axes relevant to its science program. The limits of the present analysis bound the conclusions that can be drawn from it and define the work that would extend it.
The most consequential open item is the absolute energy calibration. The pipeline propagates the ionization amplitudes through the reconstruction and can express a deposited energy in physical units, but the conversion factor relating the digitized amplitude to an energy is not yet fixed: the value inherited with the data and an independent estimate from the detector documentation differ by three orders of magnitude, and we have not been able to resolve that discrepancy from the information available. The correct procedure is to calibrate the amplitude scale against the signal of a minimum-ionizing particle, whose most probable energy loss in the argon chambers is calculable, and to anchor the scale on the position of the minimum-ionizing peak in the data, as sampling calorimeters are routinely calibrated [38]. Until that is done, any energy quoted by the pipeline is on an uncalibrated ADC scale, which is why the longitudinal profile of Section 4.1 is presented in those units and why we do not report an energy spectrum. The calibration is a defined procedure, but it must be completed before the calorimeter’s energy response can be used quantitatively.
A second limitation is set by the detector’s granularity and was already visible in the transverse profile. With a 120 mm pitch, the calorimeter resolves the ordering of the two blocks: binned at the pitch, the electromagnetic deposit of the gamma block is measurably narrower. It does not resolve the intrinsic transverse structure of an electromagnetic shower, for the reason given in Section 4.2. The lateral profile therefore establishes where the energy is concentrated and how the blocks compare. This boundary is intrinsic to the instrument and cannot be recovered by analysis.
A third limitation attaches to the longitudinal result. Plane occupancy is defined by an amplitude threshold, and Section 4.1 shows that the per-projection difference it exposes depends on that threshold, reversing for the deepest pair of planes when the threshold is raised from 5 to 30 counts. Separating a genuine difference in chamber efficiency from the baseline that the section assembly adds to an X channel requires a per-channel calibration of the chamber response, which the present processing does not attempt. Until that is done, the longitudinal profile should be read as the response of the instrument and its readout together, and the depth dependence within one projection, where the definition is held fixed, carries more weight than the comparison between the two.
The angular measurement carries a limitation of its own. Because the deepest planes yield a usable cluster in only about a third of the events at the analysis thresholds (Section 3.3), most tracks are reconstructed from two points in a projection, and the direction of a two-point track is quantized by the channel pitch and the short lever arm. The clean sample on which the angular results rest, tracks with three points in each projection, is therefore a minority of the reconstructed events, 990 in the present data, and it is drawn preferentially from the events that deposit most, as Section 4.4 makes explicit. The resulting azimuthal resolution is modest. It is not, however, what limits the isotropy that can be demonstrated: Section 4.4 shows that the of Section 4.3 is set by the plane illumination and not by the granularity, and that the granularity alone permits . A larger data set would improve the statistics of the clean sample but not its per-track resolution, which is fixed by the geometry; the resolution itself could only be improved by using the lower planes more effectively or by incorporating additional constraints, which we have not attempted here.
The residual azimuthal modulation of the clean sample is now accounted for, and what remains is a limit on the sample rather than on the explanation. Section 4.4 shows that both harmonics are produced by the events in which a plane is lit from edge to edge: the second, together with the four-fold term, by centroids that report the aperture and are placed on a zero-slope line by the alignment, and the first by the residual misalignment that the same events conceal. The events that remain give a uniform azimuth. They are, however, only 199 of the 990, and the fraction differs between the two seasons by a factor of three, so the azimuth of this instrument becomes a usable observable only after the selection is tightened to require a localized cluster in every plane entering the fit, the alignment is re-derived under that selection, and enough data are accumulated for the surviving sample to be larger than the one analyzed here. Until then the azimuthal distribution should be read as a monitor of reconstruction quality, which is how it is used in this paper, and not as a measurement of arrival directions. Separately, the absolute azimuthal reference of the instrument is not established: the orientation of the detector X axis relative to the north has not been surveyed, so all azimuths here are given in the detector frame and any conversion to right ascension carries an unknown constant rotation. Fixing this requires a site survey or a calibration against a known celestial source, and it is a prerequisite for any use of the reconstructed directions in celestial coordinates.
The last two items are matters for future development and not limitations of the present results. The extension of the track seeding to the deepest planes was necessary to obtain three-point tracks. It also increases the rate at which the finder produces short spurious tracks in high-multiplicity shower events, where the lower planes carry several disconnected clusters. These inflate the number of multi-track events but do not affect the single-track angular sample used here, and a dedicated treatment of shower-axis reconstruction in multi-track events is left for later work. The particle classification carried in the pipeline, likewise, was written against an earlier arrangement of the planes and needs to be revised for the hadron-block tracking adopted here before it can be used; we have not relied on it for any result in this paper. Indeed, with the direction fit restricted to the three planes of each hadron-block projection, the classifier’s penetrating-muon category can no longer be populated at all.
The natural next step for the analysis is a quantitative comparison with simulation. The detector-level Monte Carlo of Section 4.4 is deliberately minimal: it carries the geometry, the digitization of Equation (3) and the measured per-channel efficiencies, and it puts one channel per crossed plane. That is the right model for a localized cluster and no model at all for the plane-wide illumination that dominates the clean sample, which is why it reproduces the properly illuminated sub-sample and nothing else. Describing the rest requires a cascade. The collaboration has developed a Geant4 [37] model of the ADRON-55 calorimeter, Hadr55, that transports the particles of a simulated air shower through the detector geometry [8], and this is the appropriate tool both for correcting the zenith distribution for geometric acceptance and for validating the longitudinal and transverse response against a full description of the cascade. Section 4.5 takes the first step of that program, the response to single particles of fixed species and energy; what it does not supply, and what the shower model must, is the response to a core of mixed composition arriving over the angular and energy range the trigger accepts, together with the trigger efficiency that the summed-amplitude condition of Section 2.2 implies. It is also what would settle the lateral question directly: whether the edge-to-edge illumination is the expected response of this calorimeter to the showers that trigger the station, in which case the pipeline needs a cluster-shape requirement, or whether part of it is a common-mode artifact of the readout, in which case the raw signal needs a baseline correction that the present assembly does not apply. The pipeline has been written with this comparison in mind. It produces the same per-plane observables that a simulated event passed through the same reconstruction would yield: occupancy, deposited energy, lateral profile and reconstructed angles. Data and simulation can therefore be compared after identical processing. That comparison is the subject of a dedicated follow-up study; carrying it out, together with the acceptance correction of the angular distribution and the absolute energy calibration, would turn the characterization presented here into a fully calibrated description of the instrument.
6. Conclusions
We have described an open, reproducible analysis pipeline for the ADRON-55 ionization calorimeter at the Tien Shan station and used it to characterize the detector’s response to cosmic rays. The pipeline takes the instrument from its raw per-section data to three-dimensional tracks and per-plane observables. Its methodological content lies in three data-driven procedures that we found necessary for unbiased results: the correct assembly of the overlapping chamber sections into a position measurement; a channel-to-position calibration together with a track-based alignment of the planes; and an automatic selection of good data-taking runs that removes periods with inactive readout cameras. Each of these was arrived at by confronting the reconstruction with the data rather than by assumption, and each leaves a measurable trace in the reconstructed quantities.
Applied to events from the 2021 and 2023 seasons, the pipeline retains 243,746 good-run events, reconstructs a three-dimensional direction in 65,609 of the 86,433 quality-selected events, and delivers a clean sample of 990 single tracks with three active planes in each projection. Once per-channel normalization and pitch-matched binning are applied, the longitudinal and lateral response measured on the good-run sample behaves as expected for a crossed-plane ionization calorimeter, and it exposes a per-projection efficiency offset that depends on the threshold at which a channel is counted as hit and that motivates a dedicated chamber calibration. The azimuthal flatness of the clean sample improves by close to two orders of magnitude over the uncorrected pipeline, from to . The residual is then traced to its source. In most events of that sample, a plane is illuminated from edge to edge and carries no core, so its centroid reports the aperture and not the particle; because the alignment fixes the mean position to zero, those events are placed on a zero-slope line and their azimuth on a detector axis. Removing them lowers the flatness statistic to 2.0 under the published alignment, and to 1.2 on events held out of an alignment re-derived on the rest, at which point the first harmonic sits at the level that counting statistics alone produce and a simulation carrying the measured channel efficiencies reproduces the sample with an isotropic parent. The second harmonic of that sub-sample, against a floor of , is neither established nor excluded at this sample size. What the residual modulation of the full sample measures is thus the illumination of the planes, not the sky and not the slope lattice. The integrity audit added here, covering duplicated and misfiled raw files, closes the remaining bookkeeping gap between the recorded and the analyzable datasets.
The code and the raw data are released with persistent identifiers so that the analysis can be repeated and extended. With the absolute energy scale still to be fixed against the minimum-ionizing peak and the geometric acceptance still to be corrected with the collaboration’s Geant4 model [8], the characterization presented here is the foundation on which a fully calibrated description of the instrument, and a modern study of EAS-core absorption, can be built.
Supplementary Materials
The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/app16199816/s1, Section S1, the sensitivity of the angular results to the heuristic quality selection, with the scan of the grade thresholds and of the five weights (Table S1); Section S2, the sensitivity to the tracking parameters of Table 2 (Table S2); Section S3, the detector-level Monte Carlo, its measured per-channel efficiencies, and the single tuned parameter inside them; Section S4, the run-to-run reproducibility of the released pipeline.
Author Contributions
Conceptualization, Z.S. and T.S.; methodology, Z.S.; software, Z.S.; validation, Z.S. and K.M.; formal analysis, Z.S.; investigation, K.M. and Y.M.; resources, T.S. and Y.T.; data curation, Z.S.; writing—original draft preparation, Z.S.; writing—review and editing, T.S., A.A., K.M., D.K., Y.T., A.U. and Y.M.; visualization, Z.S.; supervision, T.S.; project administration, A.A. and D.K.; funding acquisition, T.S. and D.K. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the Science Committee of the Ministry of Science and Higher Education of the Republic of Kazakhstan, grant number AP23488396.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The analysis pipeline, including all reconstruction modules and the diagnostic scripts used to derive the calibrations, is released under the BSD 3-Clause license and archived with a persistent identifier on Zenodo, DOI: https://doi.org/10.5281/zenodo.21631377. The raw event data used in this work, 263 daily files holding 291,358 event records from the 2021 and 2023 seasons, are archived separately on Zenodo under a CC-BY-4.0 license, DOI: https://doi.org/10.5281/zenodo.21701891. Both identifiers are concept DOIs and always resolve to the most recent version. Development of the code is hosted at https://github.com/zhakansadykov/ADRON-55 (accessed on 25 September 2026). The per-event output of the Geant4 study behind Figure 6 is released with the code, under data/simulation, together with the script that draws the figure from it.
Acknowledgments
The authors thank the staff of the Tien Shan High-Mountain Scientific Station for operating the HADRON-55 complex and maintaining the raw data archive. During the preparation of this manuscript, the authors used Claude Opus 5, a large language model developed by Anthropic, as a writing aid: to improve the English, to restructure and rewrite passages of the authors’ draft, and to check the internal consistency of the figures quoted in the text. The study design, the data, the analysis, and the interpretation are the authors’ own. Every number reported here was produced by the released pipeline and can be reproduced from the archived raw data. The authors have reviewed and edited all output and take full responsibility for the content of this publication.
Conflicts of Interest
The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.
Abbreviations
The following abbreviations are used in this manuscript:
| EAS | Extensive air shower |
| ADC | Analog-to-digital converter |
| DAQ | Data acquisition |
| MIP | Minimum-ionizing particle |
| RMS | Root-mean-square |
| CV | Coefficient of variation |
References
- Sveshnikova, L.G.; Chubenko, A.P.; Mukhamedshin, R.A.; Popova, N.S.; Nikolskaya, N.M.; Yakovlev, V.I. On Abnormal Absorption of the Hadron Component of EAS Cores in Lead and Possible Explanations. arXiv 2007, arXiv:astro-ph/0701219. [Google Scholar]
- Shaulov, S.B.; Vil’danova, L.I.; Kupriyanova, E.A.; Ryabov, V.A.; Shepetov, A.L. Scaling Violation in Interaction of Cosmic Ray Hadrons and the Nature of the 3 PeV Knee in the Spectrum of Primary Cosmic Rays. J. Phys. G Nucl. Part. Phys. 2021, 48, 125202. [Google Scholar] [CrossRef] [Scilit]
- Kopenkin, V.V.; Managadze, A.K.; Rakobolskaya, I.V.; Roganova, T.M. Alignment in γ-Hadron Families of Cosmic Rays. Phys. Rev. D 1995, 52, 2766–2774. [Google Scholar] [CrossRef] [Scilit]
- Iskakov, B.A.; Argynova, A.K.; Beisenova, A.D.; Zhautykov, B.O.; Idrisova, T.K.; Novolodskaya, O.A.; Piscal, V.V.; Ryabov, V.A.; Sadykov, T.K.; Sadykov, J.T.; et al. “HADRON-55” Complex Setup for Study of Hadron Interactions within the Central Part of Cosmic Ray Extensive Air Showers (EAS) Cores. J. Instrum. 2020, 15, C12002. [Google Scholar] [CrossRef] [Scilit]
- Chubenko, A.P.; Shepetov, A.L.; Antonova, V.P.; Beisembayev, R.U.; Borisov, A.S.; Dalkarov, O.D.; Kryakunova, O.N.; Mukashev, K.M.; Mukhamedshin, R.A.; Nam, R.A.; et al. New Complex EAS Installation of the Tien Shan Mountain Cosmic Ray Station. Nucl. Instrum. Methods Phys. Res. A 2016, 832, 158–178. [Google Scholar] [CrossRef] [Scilit]
- Mukhamedshin, R.; Sadykov, T.; Serikkanov, A.; Argynova, A.; Iskakov, B.; Argynova, K.; Mahmet, H.; Novolodskaya, O.; Idrissova, T.; Zhukov, V.; et al. Studies of Anomalous Phenomena in the Development of Electron–Nuclear Cascades in the EAS Cores Registered by a Modernized Complex Installation at Mountain Altitudes. Appl. Sci. 2023, 13, 2507. [Google Scholar] [CrossRef] [Scilit]
- Sadykov, T.; Mukhamedshin, R.; Galkin, V.; Argynova, A.; Almenova, A.; Argynova, K.; Makhmet, K.; Novolodskaya, O.; Idrissova, T.; Zhukov, V.; et al. First Results of Studying EAS Cores Using a High-Mountain Ionization Calorimeter. Particles 2024, 7, 40–51. [Google Scholar] [CrossRef] [Scilit]
- Sadykov, T.; Yelemessov, O.; Mukhamedshin, R.; Galkin, V.; Argynova, A.; Argynova, K.; Makhmet, K.; Zhukov, V.; Ryabov, V.; Khussainov, Y. Simulations of the EAS Development in the Atmosphere and Detectors for Experiments with the High-Altitude Ionization Calorimeter ADRON-55. Particles 2024, 7, 768–779. [Google Scholar] [CrossRef] [Scilit]
- Mukhamedshin, R.; Sadykov, T.; Galkin, V.; Argynova, A.; Almenova, A.; Muratov, D.; Makhmet, K.; Zhukov, V.; Ryabov, V.; Piscal, V.; et al. Study of High-Altitude Coplanarity Phenomena in Super-High-Energy EAS Cores with a Thick Calorimeter. Particles 2025, 8, 74. [Google Scholar] [CrossRef] [Scilit]
- Argiró, S.; Barroso, S.L.C.; Gonzalez, J.; Nellen, L.; Paul, T.; Porter, T.A.; Prado, L., Jr.; Roth, M.; Ulrich, R.; Veberič, D. The Offline Software Framework of the Pierre Auger Observatory. Nucl. Instrum. Methods Phys. Res. A 2007, 580, 1485–1496. [Google Scholar] [CrossRef] [Scilit]
- Haungs, A.; Kang, D.; Schoo, S.; Wochele, D.; Wochele, J.; Apel, W.D.; Arteaga-Velázquez, J.C.; Bekk, K.; Bertaina, M.; Blümer, J.; et al. The KASCADE Cosmic-Ray Data Centre KCDC: Granting Open Access to Astroparticle Physics Research Data. Eur. Phys. J. C 2018, 78, 741. [Google Scholar] [CrossRef] [Scilit]
- Wilkinson, M.D.; Dumontier, M.; Aalbersberg, I.J.; Appleton, G.; Axton, M.; Baak, A.; Blomberg, N.; Boiten, J.-W.; da Silva Santos, L.B.; Bourne, P.E.; et al. The FAIR Guiding Principles for Scientific Data Management and Stewardship. Sci. Data 2016, 3, 160018. [Google Scholar] [CrossRef] [Scilit]
- Smith, A.M.; Katz, D.S.; Niemeyer, K.E. Software Citation Principles. PeerJ Comput. Sci. 2016, 2, e86. [Google Scholar] [CrossRef] [Scilit]
- Sandve, G.K.; Nekrutenko, A.; Taylor, J.; Hovig, E. Ten Simple Rules for Reproducible Computational Research. PLoS Comput. Biol. 2013, 9, e1003285. [Google Scholar] [CrossRef] [Scilit]
- Fabjan, C.W.; Gianotti, F. Calorimetry for Particle Physics. Rev. Mod. Phys. 2003, 75, 1243–1286. [Google Scholar] [CrossRef] [Scilit]
- Navas, S.; Amsler, C.; Gutsche, T.; Hanhart, C.; Hernández-Rey, J.J.; Lourenço, C.; Masoni, A.; Mikhasenko, M.; Mitchell, R.E.; Patrignani, C.; et al. Review of Particle Physics. Phys. Rev. D 2024, 110, 030001. [Google Scholar] [CrossRef] [Scilit]
- Mukashev, K.M.; Arginova, A.K.; Baisenova, A.D.; Iskakov, B.A.; Mukhamedshin, R.A.; Novolodskaya, O.A.; Piskal, V.V.; Ryabov, V.A.; Sadykov, T.K.; Serikkanov, A.S.; et al. Search for Structures in the Distribution of Particles from the Central Area of Wide Atmospheric Showers Conducted on the Adron-55 Installation. Phys. Sci. Technol. 2019, 6, 75–83. [Google Scholar] [CrossRef] [Scilit]
- ATLAS Collaboration. Topological Cell Clustering in the ATLAS Calorimeters and Its Performance in LHC Run 1. Eur. Phys. J. C 2017, 77, 490. [Google Scholar] [CrossRef] [Scilit]
- Strandlie, A.; Frühwirth, R. Track and Vertex Reconstruction: From Classical to Adaptive Methods. Rev. Mod. Phys. 2010, 82, 1419–1458. [Google Scholar] [CrossRef] [Scilit]
- Lynch, G.R.; Dahl, O.I. Approximations to Multiple Coulomb Scattering. Nucl. Instrum. Methods Phys. Res. B 1991, 58, 6–10. [Google Scholar] [CrossRef] [Scilit]
- Blobel, V. Software Alignment for Tracking Detectors. Nucl. Instrum. Methods Phys. Res. A 2006, 566, 5–13. [Google Scholar] [CrossRef] [Scilit]
- Blobel, V.; Kleinwort, C.; Meier, F. Fast Alignment of a Complex Tracking Detector Using Advanced Track Models. Comput. Phys. Commun. 2011, 182, 1760–1763. [Google Scholar] [CrossRef] [Scilit]
- CMS Collaboration. Alignment of the CMS Tracker with LHC and Cosmic Ray Data. J. Instrum. 2014, 9, P06009. [Google Scholar] [CrossRef] [Scilit]
- Harris, C.R.; Millman, K.J.; van der Walt, S.J.; Gommers, R.; Virtanen, P.; Cournapeau, D.; Wieser, E.; Taylor, J.; Berg, S.; Smith, N.J.; et al. Array Programming with NumPy. Nature 2020, 585, 357–362. [Google Scholar] [CrossRef] [Scilit]
- Virtanen, P.; Gommers, R.; Oliphant, T.E.; Haberland, M.; Reddy, T.; Cournapeau, D.; Burovski, E.; Peterson, P.; Weckesser, W.; Bright, J.; et al. SciPy 1.0: Fundamental Algorithms for Scientific Computing in Python. Nat. Methods 2020, 17, 261–272, Correction in Nat. Methods 2020, 17, 352. https://doi.org/10.1038/s41592-020-0772-5. [Google Scholar] [CrossRef] [Scilit]
- Hunter, J.D. Matplotlib: A 2D Graphics Environment. Comput. Sci. Eng. 2007, 9, 90–95. [Google Scholar] [CrossRef] [Scilit]
- Astropy Collaboration. Astropy: A Community Python Package for Astronomy. Astron. Astrophys. 2013, 558, A33. [Google Scholar] [CrossRef] [Scilit]
- Astropy Collaboration. The Astropy Project: Sustaining and Growing a Community-Oriented Open-Source Project. Astrophys. J. 2022, 935, 167. [Google Scholar] [CrossRef] [Scilit]
- Wilson, E.B. Probable Inference, the Law of Succession, and Statistical Inference. J. Am. Stat. Assoc. 1927, 22, 209–212. [Google Scholar] [CrossRef]
- Brown, L.D.; Cai, T.T.; DasGupta, A. Interval Estimation for a Binomial Proportion. Stat. Sci. 2001, 16, 101–133. [Google Scholar] [CrossRef] [Scilit]
- Künsch, H.R. The Jackknife and the Bootstrap for General Stationary Observations. Ann. Stat. 1989, 17, 1217–1241. [Google Scholar] [CrossRef] [Scilit]
- Makhmet, K.; Sadykov, T.; Galkin, V.; Mukhamedshin, R.; Argynova, A.; Tautayev, Y.; Kantarbayeva, D.; Piscal, V. Sensitivity of the “Hadron-55” Ionization Calorimeter to the Mass Composition of Primary Cosmic Rays in the Knee Region. Universe, 2026; submitted.
- Abeysekara, A.U.; Alfaro, R.; Alvarez, C.; Arceo, R.; Arteaga-Velázquez, J.C.; Avila Rojas, D.; Belmont-Moreno, E.; BenZvi, S.Y.; Brisbois, C.; Capistrán, T.; et al. All-Sky Measurement of the Anisotropy of Cosmic Rays at 10 TeV and Mapping of the Local Interstellar Magnetic Field. Astrophys. J. 2019, 871, 96. [Google Scholar] [CrossRef] [Scilit]
- Rossi, B. Interpretation of Cosmic-Ray Phenomena. Rev. Mod. Phys. 1948, 20, 537–583. [Google Scholar] [CrossRef] [Scilit]
- Gaisser, T.K.; Engel, R.; Resconi, E. Cosmic Rays and Particle Physics, 2nd ed.; Cambridge University Press: Cambridge, UK, 2016. [Google Scholar] [CrossRef] [Scilit]
- Linsley, J. Fluctuation Effects on Directional Data. Phys. Rev. Lett. 1975, 34, 1530–1533. [Google Scholar] [CrossRef] [Scilit]
- Agostinelli, S.; Allison, J.; Amako, K.; Apostolakis, J.; Araujo, H.; Arce, P.; Asai, M.; Axen, D.; Banerjee, S.; Barrand, G.; et al. GEANT4—A Simulation Toolkit. Nucl. Instrum. Methods Phys. Res. A 2003, 506, 250–303. [Google Scholar] [CrossRef] [Scilit]
- Aaboud, M.; Aad, G.; Abbott, B.; Abdallah, J.; Abdinov, O.; Abeloos, B.; Abhayasinghe, D.K.; Abidi, S.H.; AbouZeid, O.S.; Abraham, N.L.; et al. Operation and Performance of the ATLAS Tile Calorimeter in Run 1. Eur. Phys. J. C 2018, 78, 987. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.