Energy Cascade Utilization in a Building-Integrated Photovoltaic–Thermal Catalytic-Dehumidification System for Indoor Environment Regulation

,
,
,
,
,
and
1
College of Urban Construction, Nanjing Tech University, Nanjing 210009, China
2
Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230026, China
*
Author to whom correspondence should be addressed.
Buildings2026, 16(23), 4783;https://doi.org/10.3390/buildings16234783 
(registering DOI)
This article belongs to the Special Issue Indoor Air Quality, Indoor Environment and Energy Application of Sustainable Building

Abstract

The conflict between building operational energy consumption and indoor environmental quality (IEQ) presents a critical challenge in sustainable building design. To address this, we propose a building-integrated photovoltaic–thermal catalytic-dehumidification (PV-TC/DH) system that achieves energy cascade utilization through a “purification-first, dehumidification-second” series configuration. The key feature is the cascaded use of solar thermal energy: PV-generated low-grade heat (~40–60 °C) is first used to raise the temperature of the α-MnO2 thermal catalyst and to preheat the airflow, after which the heated airflow transfers its remaining sensible heat to the downstream MIL-101(Cr) layer for MOF regeneration; the adsorption heat released during night-time MOF operation provides a further, moisture-limited heating contribution. The same low-grade heat raises the operating temperature of the α-MnO2 catalytic layer, and the catalyst is active at low temperature in its own right; because the fitted activation energy is only 6.78 kJ/mol, the additional rate gained between 10 and 50 °C is modest (of order 20%), and the larger benefit of the heat lies in the regeneration of the downstream MOF layer. A transient heat and mass transfer model, validated separately for the PV-TC wall and for the PV-DH roof, was developed, and a multi-objective optimization framework (NSGA-II combined with TOPSIS) was established to identify balanced configurations. For the reference configuration in Nanjing, the simulated annual photovoltaic generation is 4532 kWh and the annual clean-air delivery is 276,129 m3; the annual dehumidification totals are not compared between cities, because the daily and annual accumulations have not been reconciled. In Nanjing the simulated cooling and heating outputs amount to 600 kWh and 665 kWh per year; these quantities are not season-matched and are therefore reported as energy outputs rather than as demonstrated load reductions, and the simple payback period of 2.5 years is a static estimate in which the sorbent is costed at the material cost of MIL-101(Cr) synthesized in our laboratory, so it remains an order-of-magnitude indication rather than a demonstrated economic case. The optimization suggests that design parameters may need to be adapted to local solar availability and humidity, but the resulting preferences are provisional, since several optima lie on the prescribed bounds. The results are model predictions for a prescribed operating sequence: no room-level heat and moisture balance was solved, so indoor thermal comfort, indoor humidity and occupant exposure are not quantified. The work indicates that building-integrated energy cascade systems can reduce the operational energy demand of an envelope, and offers an indicative pathway towards low-energy buildings rather than a demonstrated route to net-zero-energy buildings.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.