Skip to Content
BuildingsBuildings
  • Article
  • Open Access

25 November 2026

34 Pages

Assessing Longitudinal Axial-Stiffness Transferability in Steel- and GFRP-Reinforced Concrete Beams: A Study-Aware Analysis of One-Way Shear Resistance

,
,
and
1
Department of Civil and Environmental Engineering, College of Engineering, Majmaah University, Al-Majmaah 11952, Saudi Arabia
2
Department of Civil Engineering, Faculty of Engineering, Assiut University, Assiut 71515, Egypt
*
Author to whom correspondence should be addressed.

Abstract

Whether longitudinal axial stiffness (Kl = ρE) adequately represents reinforcement effects on the shear resistance of steel- and GFRP-reinforced concrete beams remains uncertain. This study analyzed 82 rectangular beams without stirrups from six experimental programs (34 steel and 48 GFRP), a 63-beam reinforcement-configuration subset, and 29 T-section beams from a single external laboratory. Study-fixed-effects regression controlled for concrete strength, effective depth, the shear-span ratio, and program origin. Exponent asymmetry between ρ and E and a categorical GFRP term tested departures from the common-stiffness representation. Only two programs provided within-program material overlap in Kl. Leave-one-program-out analysis showed substantial study dependence: omitting the Halvonik program reduced exponent asymmetry from 0.078 to 0.032 and the residual GFRP effect from +26.6% to +11.2%. Fully enumerated wild-cluster sign-flip tests did not support a robust cross-program material effect. With six programs this test has limited resolution (minimum attainable p = 0.031), so non-rejection is not evidence of no material effect. Within pooled stiffness support (50 beams), exponent asymmetry was 0.091 and the residual GFRP effect was +31.3%, both with p = 0.0625. In the configuration subset, which excluded all specimens explicitly reported as having two reinforcement layers, δ decreased to 0.015 and the residual GFRP effect to +5.3% (95% confidence interval: −17.9% to +35.1%); neither material-sensitive extension was favored by AIC. Additionally excluding six specimens whose geometry implies, but whose sources do not report, a multilayer arrangement gave +7.2% (−13.8% to +33.4%). Leave-one-study-out and external T-section predictions showed no consistent benefit from material-sensitive extensions. Longitudinal axial stiffness is a parsimonious first-order predictor in the studied slender, stirrupless domain, but neither strict material neutrality nor a universal GFRP correction is established. The absence of a transferable material term does not imply equivalent shear mechanics in steel- and GFRP-reinforced beams.

1. Introduction

Glass-fiber-reinforced polymer (GFRP) bars are increasingly used as internal reinforcement where corrosion resistance, electromagnetic transparency, or reduced maintenance demands are important. Their tensile response differs fundamentally from that of conventional reinforcing steel: GFRP bars are linear-elastic to rupture, have a substantially lower elastic modulus, and exhibit different bond and transverse stiffness characteristics. These differences affect cracking and deformation and, in shear-critical members, can modify the relative contribution of aggregate interlock, the compression zone, residual tensile transfer, and dowel action. Recent synthesis of GFRP beam design continues to identify the lower axial and bond stiffness of GFRP reinforcement as a principal reason for wider cracks and altered contributions of the shear-resisting mechanisms [1]. Earlier experimental and analytical studies likewise identified the reinforcement modulus, reinforcement amount, member depth, and the resulting crack response as central variables in fiber-reinforced polymer (FRP) shear behavior [2,3,4,5].
Early shear experiments therefore questioned whether steel-based expressions could be transferred directly to FRP-reinforced members. An early replicated test program [6] reported diagonal-tension failures in replicated GFRP-reinforced beams and attributed the unconservative predictions of the steel-based ACI expression to wider cracks, a smaller compression block, and reduced dowel action. Subsequent studies [7,8] investigated the effects of the longitudinal reinforcement amount, elastic modulus, and shear slenderness. Independent steel-versus-FRP comparisons and large-member programs [3,5] reinforced the conclusion that longitudinal reinforcement characteristics and member size materially influence shear resistance. These studies established that reinforcement properties cannot be ignored, but they did not produce a single interpretation of how material should enter a transferable shear model.
One influential interpretation is that the relevant reinforcement quantity is not material identity itself but longitudinal axial stiffness. Tureyen and Frosch [7] included a steel specimen whose tensile-reinforcement axial stiffness was intentionally made approximately equal to that of GFRP specimens. Later work showed that a simplified modified-compression-field-theory formulation, in which the longitudinal strain depends on the axial stiffness of the reinforcement, could be applied to beams flexurally reinforced with either steel or FRP [9]. A stiffness-based treatment of the longitudinal reinforcement also underlies the Canadian FRP shear provisions, and the mechanical basis of such formulations was later re-assessed against more than 300 FRP-reinforced beams [10]. In a different mechanics-based formulation, a compression-zone failure model was extended to FRP-reinforced beams by explicitly accounting for the distinct properties of FRP reinforcement [11]. Large database reviews and model assessments continue to treat the reinforcement ratio and elastic modulus as key shear variables [12,13,14,15], while the ACI and Canadian provisions use dedicated FRP formulations rather than a single categorical GFRP multiplier [16,17]; the reliability of such provisions, and of comparable national frameworks, has been assessed separately [18,19].
The experimental evidence, however, is not fully consistent with strict material neutrality of ρE. A size-effect program [20] reported a marked size effect in FRP-reinforced beams and related normalized shear strength to reinforcement axial stiffness. More recently, a later program [21] carried out a controlled comparison of steel- and GFRP-reinforced beams at a constant shear-slenderness ratio and found a strong relationship between shear resistance and longitudinal axial stiffness, while also reporting a different response per unit stiffness increase for GFRP and steel. A T-section program [22] further showed, through 29 T-section beams reinforced with steel or GFRP, that shear predictions remain sensitive to the adopted mechanical model and section characteristics. Recent experimental and analytical studies continue to report sensitivity to the reinforcement ratio, modulus, crack behavior, and the adopted design framework [23,24,25]. Taken together, the literature supports the importance of longitudinal stiffness, but it does not establish whether equal ρE is truly material-neutral across independent experimental programs.
The available FRP shear literature is now much broader than the six-program core used here for the controlled steel–GFRP question. Recent reviews assessed 147 members without stirrups [14], compiled 510 FRP-reinforced beams from more than 67 investigations [15], evaluated a 235-beam database [12], and surveyed 344 FRP-reinforced concrete (FRP-RC) shear tests for model evaluation and reliability calibration [13]. These larger databases are valuable for design-model calibration and for mapping broad parameter effects, but they combine different FRP types, geometries, detailing conventions, and laboratory programs. They therefore do not by themselves answer the narrower question addressed in this paper: whether steel and GFRP require different transferable effects after longitudinal axial stiffness and experimental-program dependence are controlled.
A central difficulty is that GFRP and steel occupy different combinations of the reinforcement ratio and modulus. At the same longitudinal axial stiffness, the lower modulus of GFRP generally requires a larger reinforcement area. Equal axial stiffness therefore does not imply equal bar area, perimeter, crack spacing, dowel capacity, or reinforcement distribution. Experimental work has shown that reinforcement layering and bar arrangement can themselves alter shear behavior [21,26]. A pooled comparison that assigns every remaining difference to a binary steel/GFRP variable may consequently confound material identity with reinforcement quantity or arrangement. A second difficulty is statistical: published databases often contain many beams but relatively few independent experimental programs, so beam-level significance can overstate the strength of cross-study evidence. A model may also improve in-sample fit without improving prediction for an unseen laboratory program.
The present study treats material neutrality as a testable restriction rather than assuming it or fitting a new material coefficient. The primary objective is to determine whether the reinforcement ratio and elastic modulus can be represented by Kl = ρE after accounting for concrete strength, size, shear slenderness, and study origin. Secondary objectives are to test whether a categorical GFRP term adds transferable predictive information and whether reinforcement configuration acts as a boundary condition. Because these questions are identifiable only where steel and GFRP occupy comparable covariate ranges, common support in longitudinal axial stiffness is quantified explicitly. The analysis combines a six-program rectangular-beam core, exponent-asymmetry and material diagnostics, study-aware sensitivities, leave-one-study-out (LOSO) validation, and an external 29-beam T-section transfer test. The aim is not to propose another empirical GFRP factor, but to assess the evidence for the equal-exponent restriction and its predictive transfer.
Relative to earlier stiffness-based studies [7,9,10,21], the contribution is methodological and diagnostic rather than a new design expression. The equal-exponent restriction implied by Kl = ρE is tested directly as a free parameter δ inside experimental programs, instead of being built into a mechanics formulation [9,10] or checked only within a single series [7,21]. The experimental program, rather than the individual beam, is treated as the unit of replication for both inference and validation, and the effect of ignoring that structure is quantified on the same data. Common support in Kl is also mapped explicitly, so that the general influence of Kl (identified from within-program variation) can be separated from material differences that appear only where steel and GFRP specimens actually overlap. The practical aim is therefore to state what the available paired steel–GFRP evidence can and cannot support: whether a categorical GFRP correction is transferable, and where the reinforcement ratio or arrangement, rather than material identity, may account for apparent material effects.

2. Database and Methods

2.1. Study Scope and Inclusion Criteria

The primary database was restricted to reinforced concrete beams in which the longitudinal reinforcement was either conventional steel or GFRP. Hybrid steel–GFRP longitudinal reinforcement was excluded because the available conventional stirrupless hybrid evidence was concentrated in a single experimental program and could not support a study-independent interaction term. Carbon-fiber-reinforced polymer (CFRP) and aramid-fiber-reinforced polymer (AFRP) specimens contained in otherwise eligible studies were also excluded so that the material comparison remained specifically steel versus GFRP.
The strict core comprised rectangular, normal-weight concrete beams tested monotonically without transverse reinforcement in the critical shear span. Specimens were required to have a shear-span-to-effective-depth ratio a/d ≥ 2.5 and a governing shear-type failure. These rules were adopted to reduce direct arching action and to keep the core mechanically coherent. Beams with a/d approximately 2.4–2.43 were retained separately for threshold sensitivity rather than moved into the core after inspecting the results. T-section specimens were likewise reserved for external geometry validation. Deep beams, beams with shear reinforcement, nonconventional concrete systems, and non-shear governing failures were not used in the primary model.
The resulting strict rectangular core contains 82 beams from six independent experimental programs: 34 steel-reinforced and 48 GFRP-reinforced beams. The programs span early replicated GFRP tests [6], direct steel–FRP comparisons [7,8,21], and a size-effect program [20]. Table 1 summarizes the evidence base used for the primary analysis, and Table 2 defines the principal variables used in the analysis.
Table 1. Experimental programs included in the strict rectangular core. Panel A: geometry, shear span, concrete strength, and loading; Panel B: longitudinal reinforcement by program and material.
Table 2. Principal variables used in the analysis.
Database selection followed a sequential screening procedure. The reason for each exclusion is recorded in Supplementary Table S1. Candidate programs were drawn from the FRP shear databases and reviews cited above [12,13,14,15,29], their source lists, and recent experimental programs. The decisive requirement was a paired-program design: a program entered the core only if it tested both steel- and GFRP-reinforced stirrupless beams under the same experimental conditions. This requirement follows from the inferential structure rather than from convenience. Under study fixed effects, a GFRP-only or steel-only program supplies no information on the categorical material term γ, because its material contrast is absorbed by its own intercept. Its contribution to the exponent-asymmetry test is likewise limited to the combined reinforcement-ratio exponent, so it cannot separate material identity from reinforcement quantity. Most specimens in the larger compilations [12,13,14,15] come from FRP-only programs and therefore cannot address the within-program steel–GFRP contrast that is the subject of this paper. The remaining criteria—no transverse reinforcement in the critical span, a rectangular normal-weight concrete section, monotonic simply supported testing, a/d ≥ 2.5, shear-governed failure, and specimen-level data verifiable in the primary source—were applied in that order. Paired programs that failed a later criterion were not discarded without record: the T-section program [22] was retained for external validation and the near-threshold program [24] for a/d sensitivity.
Expansion of the core with additional paired programs was considered and remains desirable, but it was not feasible under the present eligibility rules. Paired steel–GFRP programs of stirrupless rectangular beams are scarce relative to FRP-only programs in the published record. Relaxing the rules would increase the number of beams, yet it would also introduce precisely the sources of heterogeneity—stirrups, flanges, arching action, fiber-reinforced or lightweight concrete—that the study-aware design seeks to exclude. The adequacy of the present core is therefore claimed only for two distinct questions. The general association between Kl and shear strength is identified from within-program variation across all six programs (82 beams), and its stability is checked by deleting each program in turn (Section 3.2). Material differences at comparable Kl, by contrast, are identified directly only by the 17 beams from the two programs that lie in within-program common support (Table 3). Conclusions concerning material effects are limited accordingly.
Table 3. Within-program common support in longitudinal axial stiffness.
The material scope was restricted to steel and GFRP for three reasons. First, the paper asks whether a categorical GFRP correction, of the kind sometimes proposed for design, remains necessary once Kl is controlled. GFRP is the FRP type most widely used as internal reinforcement and is the material addressed by dedicated design provisions [16]. Second, each additional FRP type introduces a new material identity together with a new modulus range, bar surface, and bond and transverse stiffness characteristics. Including CFRP, AFRP, or BFRP specimens could broaden the modulus range and provide additional material comparisons. Modulus variation may nevertheless remain associated with the fiber type and bar-product characteristics. Whether the exponent-asymmetry and material terms could be distinguished would need to be assessed from the within-program variation and overlap in the expanded database. Third, BFRP-reinforced stirrupless beams appear mainly in FRP-only programs [3], which do not provide the within-program steel comparison required here. A multi-material extension is nevertheless a natural next test of the stiffness representation and is identified as future work in Section 3.6. Such an extension would require a separate fiber-type term and replicated programs that include more than one FRP type together with steel companions.

2.2. Data Extraction, Provenance, and Audit

The analysis unit was the physical beam. Where a published program reported repeated shear outcomes from the same physical beam, the repeated outcomes were retained in the source audit and combined to a beam-level response before the cross-study analysis, preventing repeated outcomes from being treated as independent specimens. Each record retained a study identifier and beam identifier so that experimental-program dependence could be modeled explicitly.
The specimen-level data were audited directly against the original publications, including checks of geometry, reinforcement, concrete strength, shear resistance, and failure classification. The 82 strict-core beams were classified into two mutually exclusive provenance categories (Supplementary Tables S2 and S3). First, 68 rows were verified at the specimen level from the original publications: 7 Tureyen and Frosch beams [7], 12 Tariq and Newhook beams [27], 12 Halvonik GFRP beams [21], 6 Alam and Hussein beams [20], 10 El-Sayed et al. beams [8,28], and 21 Yost et al. beams [6]. The Alam and Hussein rows were checked directly against the original full text and its tabulated data [20]. Of the ten El-Sayed rows, the six normal-strength Series I–III specimens were verified directly against the primary article and its tabulated data [8], where the reported integer bar schedules reproduce the printed reinforcement ratios and axial stiffnesses exactly; the four high-strength SH/GH rows were verified in the same authors’ companion primary experimental report [28], which reports those specimens and their row-level reinforcement, concrete strength, and experimental shear resistance. Second, 14 additional Halvonik steel rows were verified directly for geometry, reinforcement area, concrete strength, paired shear outcomes, and failure information, but were classified separately because the primary paper does not report the steel elastic modulus Es. Full-text review confirms that the only moduli it states numerically are the concrete modulus and the GFRP Ef = 46.2 GPa, with Es entering only through the modular ratio Ef/Es of the Eurocode-based design models the study evaluates, for which 200 GPa is the prescribed design value. These rows therefore use Es = 200 GPa as an explicit working assumption aligned with the source’s own design framework, and carry a 190–210 GPa sensitivity. The 21 Yost et al. rows were obtained directly from the original article [6], whose own figure and table of specimen details provide the cross-sectional details and shear-failure loads for all specimens. The adopted concrete strength was 36.3 MPa, as used by the authors in their calculations at the time of testing. Designs 5FRP and 6FRP used three #7 bars (1161 mm2), and the steel design used four #5 bars (794 mm2). These values were used consistently throughout the analyses and are documented in the supplementary workbook. Thus, all 82 strict-core beams were verified against the original publications. For 68 beams, all variables used in the analysis were directly verified at the specimen level; for the remaining 14 beams, the only unresolved source quantity was the steel elastic modulus Es, which was addressed through the stated sensitivity analysis. The Halvonik program contributed 26 of the 82 core beams and included the two-layer reinforcement configurations considered in the configuration sensitivity analysis. The original study reported 24 tests on 12 GFRP beams and 28 tests on 14 steel beams, with two shear outcomes reported for each physical beam. The paired outcomes were therefore averaged so that each physical beam entered the analysis once. The reported beam geometry was b = 95 mm, d = 100 mm, a = 300 mm, and a/d = 3.0, with a concrete compressive strength of f′c = 31.5 MPa. Because the concrete properties were reported as averages of three samples tested at the time of beam testing, the same reported strength was assigned to the corresponding Halvonik beams [21]. In the Halvonik et al. [21] test program, beams A7, B5, and B6 had an overall depth of 145 mm to accommodate two reinforcement layers while maintaining an effective depth of d = 100 mm. For Alam and Hussein, the published rounded Kl values were retained. Because ρ and Al were not reported independently, they were derived from Kl/E and Al = ρbwd using the reported effective bar modulus. The supplementary workbook identifies these derived quantities separately from directly reported values. These provenance classifications are used only to document data origin and do not affect specimen weighting or inclusion in the primary core.
An inconsistency was identified in the ordering of the experimental shear values reported by Alam and Hussein [20]. Their tabulated results do not align unambiguously with the printed specimen order, whereas their specimen-level results report Vexp explicitly for each FRP specimen. The database therefore adopted the latter specimen-specific assignments. The remaining steel values were assigned consistently with the corresponding reinforcement series and specimen ordering. No experimental value was modified; the resolution concerned only the association of published values with specimen identifiers. Both the alternative reading and the adopted assignments are documented in the Source Audit worksheet of the supplementary workbook.

2.3. Variables, Normalization, and Common Support

The experimental shear response was expressed as nominal shear strength vu rather than total load so that beams of different width and effective depth could be compared on a common stress basis:
v u   =   V u b w   d
where Vu is the experimental shear force at failure, bw is the web width, and d is the effective depth. The longitudinal reinforcement ratio and longitudinal axial stiffness were defined as
ρ = A l b w   d
K l = ρ E
where Al is the area of longitudinal tensile reinforcement and E is the elastic modulus of the corresponding steel or GFRP reinforcement. Kl therefore has stress units and represents reinforcement axial stiffness normalized by the effective concrete section bw d. The primary regression response was ln(vu), used throughout as shorthand for ln[vu/(1 MPa)]. Continuous predictors were represented logarithmically because the principal mechanical effects are expected to act multiplicatively and because the database spans more than one order of magnitude in Kl. All logarithms were written as dimensionless ratios using fixed reference values: K0 = 1000 MPa, ρ0 = 0.01, E0 = 100 GPa, f0 = 40 MPa, d0 = 100 mm, and (a/d)0 = 3.0 (Supplementary Table S4). These values are round scaling constants chosen within the range of the strict-core database; they are not fitted parameters or code thresholds. K0 = ρ0E0 by construction. For the study-fixed-effects inference, the continuous log predictors were subsequently centered within the experimental program. Consequently, the fixed reference constants cancel under within-study centering and do not affect the fitted slopes, material diagnostics, confidence intervals, or predictions; they serve only to make the displayed equations dimensionless and interpretable.
Because a material comparison is only informative where the covariate ranges overlap, the distribution of Kl was examined by material and experimental program before inference. The coverage plot is retained as a diagnostic rather than treated as evidence of a material effect.
Study fixed effects remove program-level offsets, but they cannot create steel–GFRP comparability where the two materials occupy disjoint Kl ranges within a program. Common support was therefore assessed explicitly. For each experimental program, the steel and GFRP support intervals were defined by their observed minimum and maximum Kl values; the within-program overlap interval was the intersection of those two ranges, and the numbers of steel and GFRP beams inside that interval were counted (Table 3). A direct-support subset retained only observations lying inside their own program-specific overlap interval. A less stringent pooled-support sensitivity retained every core beam within the global intersection of the steel and GFRP ranges, 719.8 ≤ Kl ≤ 3437.8 MPa (n = 50), and refitted the study-aware material and exponent-asymmetry diagnostics. The direct-support subset was used primarily as an identification diagnostic because it contained only 17 beams from two programs. After excluding every source-reported two-layer configuration and recalculating the within-program support intervals, no steel–GFRP common support remained in the 63-beam configuration subset.
Overlapping Kl ranges should not be mistaken for comparability. Where steel and GFRP beams come from different laboratories, matching their Kl values does not remove the differences between those laboratories in concrete mixture and aggregate, curing, specimen fabrication, loading and support details, instrumentation, and the definition of failure. A steel beam from one program and a GFRP beam from another with the same Kl therefore differ in material and in laboratory at the same time, and no amount of numerical overlap separates the two. This is why the direct-support subset admits only pairs from the same program, and why the pooled-support sensitivity, which allows cross-laboratory pairs, is interpreted as a range restriction rather than as a controlled comparison. Even within one program, overlap removes laboratory effects only to the extent that the steel and GFRP specimens were cast, tested, and evaluated under the same conditions.

2.4. Primary Study-Aware Model

The primary model was specified before the final robustness analyses as a study-fixed-effects log-linear relation. Study fixed effects were preferred to interpreting a random-effect variance because the strict core contains only six independent experimental programs. The model was
ln ( v u ) = α j + β K   ln ( K l K 0 ) + β c   ln ( f ′ c f 0 ) + β d   ln ( d d 0 ) + β a / d   ln ( ( a / d ) ( a / d ) 0 ) + ε
where αj is a program-specific intercept and ε is the within-study residual; K0, f0, d0, and (a/d)0 are the fixed reference values defined in Section 2.3. Continuous predictors were centered within the experimental program for inference, so the material-related tests primarily use within-program contrasts while the fixed intercepts absorb program-level differences in concrete characterization, loading details, laboratory procedures, and other unmeasured study characteristics. Because subtracting a fixed logarithmic reference and then centering within the study is algebraically equivalent to centering the unscaled logarithm directly, the selected reference values have no effect on the estimated slopes. The principal coefficients were evaluated by effect magnitude, confidence interval, information criteria (Akaike information criterion, AIC), residual behavior, and transferability rather than by p-value alone.
Because study fixed effects identify continuous slopes only from variation within experimental programs, coefficient identification was checked explicitly. For each continuous predictor, the contribution of each program to the within-study centered sum of squares was calculated. The primary model was then refitted six times, each time omitting one complete experimental program, and the stability of βK, βc, βd, and βa/d and the design-matrix condition number were examined. These diagnostics distinguish variables that are adequately supported across programs from nuisance controls whose numerical coefficients depend strongly on one program.

2.5. Material-Sensitive Tests of the Axial-Stiffness Representation

The assumption Kl = ρE imposes an important restriction: the reinforcement ratio and elastic modulus enter with the same exponent. Let η0 denote the baseline linear predictor from Equation (4), excluding ε. To test the restriction directly, the model was augmented by an exponent-asymmetry term:
ln ( v u )   =   η 0   +   δ [ ln ( ρ ρ 0 )   −   ln ( E E 0 ) ]   +   ε
Because ln(Kl/K0) = ln(ρ/ρ0) + ln(E/E0) when K0 = ρ0E0 = 1000 MPa, Equation (5) is equivalent to fitting separate exponents βρ = βK + δ and βE = βK − δ. The equal-exponent restriction corresponds to δ = 0; testing this null is not a formal equivalence test. This parameterization is preferable to interpreting ρ and E as unrelated predictors because it tests the exact mechanical restriction of interest. As in the baseline model, the logarithmic terms are centered within the experimental program for inference, so the numerical choices of ρ0 and E0 do not alter δ.
A categorical GFRP indicator IGFRP was added separately to the same baseline predictor as a diagnostic:
ln ( v u )   =   η 0   +   γ   I GFRP   +   ε
The term γ was not treated as a candidate design multiplier merely because it improved in-sample fit. A universal material correction was considered supportable only if its magnitude was stable to the predefined sensitivity analyses and if it improved prediction of experimental programs not used for fitting. The material-indicator model was also compared with a reinforcement-ratio extension to determine whether a continuous physical variable could account for the same apparent difference.
Information criteria were computed with the maximum-likelihood residual variance ( σ ^ 2 = RSS / n ), treating the study intercepts, the slopes, and σ as estimated parameters; ΔAIC is reported as AIC(baseline) − AIC(extension), so positive values favor the extension in sample. Under the unbiased variance convention the near-zero configuration-subset values change sign, which does not alter the interpretation because both lie well inside the ΔAIC < 2 range of no meaningful preference.
One identification limit of this parameterization should be stated explicitly. Within an experimental program, the elastic modulus is effectively a property of the reinforcement type rather than of the individual specimen: 99.98% of the within-study variance in ln E in the strict core lies between the steel and GFRP groups, against 28.9% for ln ρ. After study fixed effects and the four physical controls are partialled out, the exponent-asymmetry regressor and the categorical GFRP indicator are therefore almost perfectly aligned, with a residual correlation of 0.997 in the strict core and 0.994 in the reinforcement-configuration subset. In this database δ and γ are consequently near-reparameterizations of a single steel–GFRP contrast rather than independent diagnostics, and their close agreement across scenarios should be read as one body of evidence expressed in two ways rather than as mutual corroboration. It follows that δ cannot be interpreted mechanically as evidence that ρ and E carry genuinely different exponents; separating those exponents would require within-program variation in E that is independent of the reinforcement type, which no program in the present core provides. This limitation is itself an instance of the paper’s central point, that material identity, reinforcement quantity, and reinforcement configuration are not separately identified in the available experimental record.
Two regressors that carry almost the same information cannot be distinguished by the data, so whichever one is included absorbs the effect of the other. In the present core, the steel beams are exactly the high-modulus beams and the GFRP beams are exactly the low-modulus beams, so “an effect of being GFRP” and “an effect of a lower modulus than the ρE product allows for” describe the same steel–GFRP contrast. When δ and γ agree, as they do in every scenario examined in Section 3.3, they are reporting this one contrast twice, not confirming each other. Separating them would require beams of the same material with different moduli, or of different materials with the same modulus, tested within one program. The reach of the material conclusions should be judged with two numbers in mind: only 17 of the 82 beams lie in within-program steel–GFRP common support, and the two material diagnostics are correlated at 0.997 after adjustment.

2.6. Sensitivity Analyses and Boundary Conditions

The complete 82-beam core remained the primary dataset. A 63-beam reinforcement-configuration sensitivity set was formed by excluding every specimen explicitly reported by its original source as having two layers of longitudinal reinforcement. In the Halvonik et al. program, beams A7, B5, and B6 used two reinforcement layers and had an overall depth of 145 mm while maintaining an effective depth of d = 100 mm, accounting for six physical beams. El-Sayed et al. explicitly reported two-layer longitudinal reinforcement throughout the relevant test programs. The normal-strength article states that the clear spacing between the two reinforcement layers was 30 mm for all beams, while the companion high-strength article reports two bottom reinforcement layers for all nine beams. Accordingly, all ten El-Sayed specimens included in the present core were excluded from the configuration sensitivity set. Tureyen and Frosch show the Series 2 specimens ρ = 1.92% with two layers of longitudinal reinforcement and a total depth of 427 mm, compared with 406 mm for the single-layer specimens. Accordingly, V-S-2, V-G1-2, and V-G2-2 were classified as two-layer specimens, whereas the Series 1 specimens and V-D-2 were classified as single-layer specimens. This accounts for three additional beams excluded from the configuration sensitivity set. Yost et al. show all seven reinforcement designs in a single layer. In contrast, Alam and Hussein and Tariq and Newhook do not explicitly report the longitudinal-reinforcement layer arrangement for their specimens. Alam and Hussein provide only a generic test-setup schematic and report a 40 mm clear cover, while Tariq and Newhook represent the longitudinal reinforcement schematically and report only the total reinforcement area. Accordingly, the layer arrangement of their 18 core specimens was recorded as “not reported.” These specimens were retained in the configuration sensitivity set because the exclusion criterion was restricted to specimens explicitly identified by their original sources as having two reinforcement layers. For six of these specimens—Alam and Hussein G-500 and G-650 and the four Tariq and Newhook beams with ρ = 1.54%—the reported reinforcement could not be accommodated in a single layer at the stated cover while satisfying the CSA A23.3-04 minimum clear-spacing requirement. For the four Tariq and Newhook specimens, the reduction in effective depth from 346 to 325 mm at unchanged overall depth provides additional evidence of a multilayer arrangement. However, because the reinforcement layer arrangement was not explicitly reported in the original sources, these observations were treated as geometric inferences only. The six specimens therefore remained classified as “not reported” and were retained in the configuration sensitivity set. Accordingly, the 19 specimens explicitly reported as having two layers of longitudinal reinforcement were excluded, leaving a 63-beam configuration-sensitivity subset drawn from five experimental programs. Because the subset was defined solely on the basis of source-reported reinforcement configuration, specimens with unreported layer arrangements were retained. The source flags B5.2b, B6.1a, and B6.2a as unusually high responses and associates this behavior with the two-layer GFRP arrangement; a beneficial two-layer response was also reported for steel A7. No physical beam was deleted from the predefined core on that basis: paired test outcomes were first aggregated to the physical-beam level, and the configuration sensitivity removes complete source-reported two-layer configurations rather than selectively deleting high individual outcomes. Additional sensitivities removed the Halvonik A4.2 physical beam associated with an author-identified side-test outlier; every specimen whose source records flexural yielding before diagonal-tension failure, namely Tureyen and Frosch V-D-2 and El-Sayed SN-0.9; both A4.2 and the yielded specimens together; and the Alam and Hussein program as a whole-program sensitivity because it contributes most of the within-study depth variation. Halvonik steel Es was varied from 190 to 210 GPa. A further 14 rectangular beams with a/d approximately 2.4–2.43, drawn from two programs [20,24], were retained as a near-threshold sensitivity set, with shear-flexural cases separately identified. The 12 specimens contributed by [24] were verified row by row against the original article. The paper reports the reinforcement ratio, bar schedule, concrete strength, and maximum load for each beam. Because the specimens were tested under a single midspan point load, the experimental shear force was taken as one half of the reported maximum load. The specimen drawing in the source article [24] shows a single bottom reinforcement layer with 40 mm cover, and its specimen table reports d = 350 mm for all 12 specimens. These beams were therefore classified as source-reported single-layer specimens. Finally, the exponent-asymmetry and categorical-material models were refitted after omitting each complete experimental program, both for the strict core and for the pooled common-support subset, to test whether the apparent material-sensitive estimates were stable to whole-program deletion.
Because 18 specimens in the configuration subset have unreported arrangements, two further sensitivities bracket the effect of that uncertainty (Supplementary Table S5). The first removes from the 63-beam subset the six specimens whose reported reinforcement cannot be placed in one layer at the stated cover (Alam and Hussein G-500 and G-650 and the four Tariq and Newhook beams with ρ = 1.54%), leaving 57 beams from five programs. The second retains only specimens whose sources explicitly report a single layer, leaving 45 beams from three programs (Halvonik et al., Tureyen and Frosch, and Yost et al.). The second subset has too few programs for informative few-cluster or leave-one-study-out inference, because its sign-flip p-value cannot fall below 2/23 = 0.25 and two training programs cannot identify the size and slenderness controls; its estimates are therefore reported descriptively.
Program-level leverage was quantified separately by leave-one-program-out refitting. Each experimental program in turn was removed in full, and the exponent-asymmetry parameter and the categorical GFRP coefficient were re-estimated on the remaining programs for both the strict core and the pooled common-support subset. This diagnostic asks a different question from the coefficient-stability refits of Section 3.2, which concern the continuous controls: it tests whether the apparent material signal itself is reproduced across independent laboratories, or is carried by one of them.

2.7. Statistical Inference with Few Experimental Programs

Conventional cluster-robust standard errors were calculated at the experimental-program level. Because the number of independent programs was small, inference for the material-sensitive coefficients δ and γ was supplemented by fully enumerated Rademacher wild-cluster sign-flip tests. Under each null restriction, residuals from the restricted model were multiplied by study-level weights of +1 or −1, and the unrestricted model was refitted for every possible sign pattern. The enumeration was performed separately for each analysis specification. Thus, G = 6 programs yielded 26 = 64 sign patterns, G = 5 yielded 25 = 32, and G = 7 yielded 27 = 128 (Supplementary Table S6).
For the two-sided test based on the absolute test statistic, sign-reversed patterns are mirror pairs, so the minimum attainable non-zero p-value is 2/2G: 0.0625 for five programs, 0.03125 for six programs, and 0.015625 for seven programs. Consequently, a five-program specification cannot attain p < 0.05, irrespective of effect magnitude. Full enumeration removes Monte Carlo error, but the validity of the procedure still depends on the assumptions underlying cluster-level sign symmetry and independence.
The sign-flip p-values were therefore treated as few-cluster sensitivity diagnostics rather than as standalone evidence of absence or presence of a material effect. Interpretation emphasized effect magnitude, confidence intervals, common support, and out-of-study transferability. Conventional cluster-robust p-values and confidence intervals used a t(G − 1) reference distribution as a finite-sample convention; given the small number of programs, these intervals were interpreted together with the fully enumerated sign-flip results.

2.8. Transferability Assessment

Transferability was evaluated by LOSO validation using a prediction model that was deliberately distinct from the study-fixed-effects model used for inference (Supplementary Table S7). For each fold, the complete held-out experimental program was removed before fitting. The remaining programs were then fitted by study-balanced weighted least squares with a single common intercept and no study-dummy terms. If training program j contained nj beams, every beam in that program received weight wij = 1/nj, so each training program contributed a total weight of one regardless of its specimen count. The Kl-only prediction model used the same physical predictor set—ln(Kl), ln(f′c), ln(d/100), and ln(a/d)—with one common training intercept; the alternative models replaced the reinforcement representation with separate ρ/E effects or added a categorical GFRP indicator. No observations from the held-out program were used to estimate coefficients, centering constants, a program intercept, or any recalibration factor. Thus, an unseen study was not predicted by assigning it the reference-study fixed effect or by setting an unknown study dummy to zero; rather, it was predicted from the common intercept and slopes learned only from the remaining programs. Predictions were generated on the log scale and transformed as vpred = exp(ŷ), without a retransformation/smearing correction. The same procedure was applied to the strict 82-beam core and, after every source-reported two-layer specimen had been removed before fold construction, to the 63-beam reinforcement-configuration subset, which contains five programs and therefore five folds. Performance was summarized by mean Vexp/Vpred, mean absolute percentage error (MAPE) = mean(|vexp − vpred|/vexp) × 100, root-mean-square error (RMSE) in nominal shear stress, and the proportions satisfying 0.80 ≤ Vexp/Vpred ≤ 1.20 and 0.70 ≤ Vexp/Vpred ≤ 1.30. Training was therefore balanced by experimental program, whereas the reported overall prediction metrics pool all held-out beam predictions, with each beam entering exactly once.
Back-transforming a log-scale prediction by exp(ŷ) estimates the conditional median rather than the conditional mean of vu. Under approximately normal log-scale errors, the mean exceeds the median by the factor exp(σ2/2). With the study-weighted training residual standard deviation of 0.142 (core) and 0.122 (configuration subset), this factor is 1.010 and 1.007, and the corresponding nonparametric smearing factors are 1.011 and 1.008. The uncorrected predictions are therefore expected to be biased low in the mean by about 1%, which is small relative to the between-program differences reported in Section 3.4. As a check, each LOSO fold was repeated with a fold-specific smearing factor estimated from its training residuals; the resulting metrics are reported in Supplementary Table S8.
A separate published program comprising 29 slender T-section beams without transverse reinforcement—13 steel-reinforced and 16 GFRP-reinforced specimens [22]—was reserved for external geometry-transfer assessment. The specimen-level data were verified against the original publication, including the shear-span ratio, web width, effective depth, concrete strength, reinforcement properties, and experimental shear resistance. The model calibrated on the predefined 82-beam rectangular core was then applied to these T-section beams without recalibration or introduction of a T-section correction factor. The predefined core model was used for this external assessment because it represents the primary model of the study, whereas the 63-beam set was defined only as a reinforcement-configuration sensitivity analysis. Prediction bias and MAPE were evaluated overall and separately for steel and GFRP. An ordinary least-squares regression of ln(Vexp/Vpred) on an intercept and IGFRP was then used as a descriptive within-program residual comparison, with a conventional t reference on 27 residual degrees of freedom. This comparison assesses whether transfer bias differs by material within that program; it cannot separate section geometry from laboratory-specific conditions: if both reinforcement types exhibit a similar residual shift, the shared discrepancy provides no direct evidence for a universal GFRP correction.
This T-section set is external to the calibration data, but all 29 beams come from one laboratory. Its overall bias therefore combines the effect of section geometry with the conditions of that laboratory, and the steel–GFRP residual comparison within it is a same-laboratory comparison rather than an independent validation of material neutrality.

2.9. Reproducibility and Analysis Framework

The analysis used a predefined core of 82 beams from six experimental programs, with source provenance, derived variables, model specifications, and sensitivity analyses documented systematically (Supplementary Table S9). Model assessment included within-study explanatory performance, collinearity, residual diagnostics, and observation-level influence; diagnostic plots are provided in Supplementary Figures S1–S4. Robustness was evaluated through fully enumerated wild-cluster sign-flip tests, common-support and reinforcement-configuration analyses, source-provenance checks, and whole-program deletion. Transferability was assessed using leave-one-study-out prediction and an independent T-section program.
No observations were removed from the primary analysis. The 63-beam configuration subset was examined as a mechanistically motivated sensitivity defined entirely by source-reported reinforcement arrangement. Conclusions were based on consistency across effect estimates, study-aware uncertainty, sensitivity analyses, and predictive performance, rather than on any single exclusion or significance threshold.
During the preparation of this manuscript, the authors used ChatGPT (GPT-x, OpenAI) and Claude Fable 5.2 (Anthropic) to refine the wording and the presentation of figures and to assist with cross-checking the pertinent literature. These tools were not used to generate the data, the analyses or the results. The authors reviewed and edited the AI-assisted content and take full responsibility for the content of this publication.

3. Results and Discussion

3.1. Database Coverage and Axial-Stiffness Trends

The strict core contained 82 beams from six programs (34 steel, 48 GFRP), spanning Kl = 303–4762 MPa, d = 100–608 mm, f′c = 31.5–63.0 MPa, and a/d = 2.50–4.08. Within-program material overlap in Kl was sparse: four programs had none; Halvonik overlapped at 1786–3438 MPa and Tureyen and Frosch at 720–778 MPa. Only 17/82 beams lay within study-specific steel–GFRP common support (Figure 1; Table 3).
Figure 1. Common support in longitudinal axial stiffness by experimental program. Yost et al. [6], Tureyen & Frosch [7], Tariq & Newhook [27], El-Sayed et al. [8,28], Alam & Hussein [20], and Halvonik et al. [21].
In the configuration subset, all four overlapping Halvonik GFRP beams are B5/B6 two-layer configurations and the overlapping Tureyen Series 2 specimens are also two-layer, so a replicated material effect is not estimable from direct within-program overlap alone. As a less stringent sensitivity, restricting the full core to the pooled steel–GFRP support interval 719.8–3437.8 MPa retained 50 beams and gave δ = 0.091 (95% confidence interval (CI) 0.047 to 0.135) and a residual GFRP effect of +31.3% (17.6% to 46.5%), with a fully enumerated six-study sign-flip p-value of 0.0625 for both diagnostics. The positive point estimates therefore persist under pooled range restriction, and are larger than in the full core; the restriction neither produces robust cross-study inference nor resolves the absence of replicated within-program overlap in four programs.
A clear positive association between nominal shear strength vu and Kl was observed for both reinforcement materials (Figure 2). The relationship should not be interpreted as a single universal curve, because member size, shear slenderness, concrete strength, and study origin also vary across the database [29]. Nevertheless, the common positive trend supports the long-standing mechanics view that longitudinal reinforcement stiffness is relevant to shear resistance in both steel- and FRP-reinforced members [7,9,10,11]. The highest GFRP shear strengths in the core occurred in the Halvonik two-layer configurations [21]; these beams were retained in the predefined primary analysis and later treated explicitly as a configuration boundary condition rather than being removed from the database.
Figure 2. Nominal shear strength versus longitudinal axial stiffness in the strict rectangular core.

3.2. Study-Aware Effects of Stiffness, Size, and Shear Slenderness

The primary study-fixed-effects model estimated a positive within-program association of longitudinal axial stiffness. The coefficient of ln(Kl) was βK = 0.265 (cluster standard error (SE) = 0.030; conventional cluster p < 0.001; 95% CI 0.188 to 0.343; Table 4). Because both response and stiffness were log-transformed, a 10% increase in Kl corresponds to an increase of approximately 2.6% in nominal shear strength when the other modeled variables and study effect are held fixed. More importantly for transferability, βK remained between 0.245 and 0.284 in all six leave-one-study-out coefficient refits (Table 5), indicating that the positive stiffness association is not dependent on any single experimental program.
Table 4. Primary study-fixed-effects model for nominal shear strength.
Table 5. Leave-one-study-out stability of the primary model coefficients.
The effective-depth and shear-span coefficients are less transferable. Alam and Hussein contributed 97.6% of within-study ln(d) variation, Tariq and Newhook 99.75% of ln(a/d) variation, and El-Sayed et al. 58.6% of within-study ln(f′c) variation. Deleting the first two programs changed βd from −0.511 to −4.995 or βa/d from −0.893 to +1.379 and raised the condition number of the within-study design from 17 to 95 and 309, respectively (Table 5); the concrete-strength exponent is likewise a single-program estimate, which is why it is reported with a wide interval and is not interpreted as a transferable law. Accordingly, d and a/d are retained as physically motivated adjustment controls rather than independently generalizable exponents [30,31].
The distinction between including d and a/d as regression predictors and establishing a transferable size-effect or slenderness law is therefore essential. The fitted βd and βa/d adjust the within-program comparisons for the depth and slenderness variation that each program contains; they are not estimates of a general size-effect exponent, which would require several programs with independent within-program variation in d. The quantities of primary interest are nevertheless robust to the two programs that carry this variation. Deleting Alam and Hussein or Tariq and Newhook changes βK only from 0.265 to 0.270 and 0.284 (Table 5) and the residual GFRP effect only from +26.6% to +24.6% and +25.0% (Supplementary Table S10), so the stiffness and material diagnostics are not artifacts of the unstable size and slenderness coefficients.
For practice, the fitted βd and βa/d should not be adopted to build or recalibrate a shear design equation. Each is estimated almost entirely from one program, changes by an order of magnitude or reverses sign when that program is removed, and describes the depth or slenderness trend of that program’s specimens rather than a size or arch-action law. A design expression built on them would extrapolate one laboratory’s trend to all members, and it would carry none of the safety formats, material resistance factors, or reliability calibration on which code provisions rest [16,17,18]. Size and slenderness effects in design should continue to be taken from mechanics-based provisions calibrated on purpose-designed series [20,30,31].
A control-omission sensitivity supports this interpretation. Removing d changed the full-core exponent-asymmetry estimate negligibly (δ = 0.079) and left the residual GFRP effect at approximately +26.9%. Removing a/d reduced δ to 0.062 and the residual GFRP effect to approximately +20.9%; omitting both controls gave similar values (δ = 0.063; GFRP effect ≈ +21.5%). Thus, the weak identification of a/d affects the magnitude of the material diagnostics, but it does not reveal a larger hidden material effect. The primary model retains both d and a/d because they are mechanically relevant confounder controls, while their fitted coefficients are not used as independent evidence of universal size or shear-span laws.
Model diagnostics support use of the regression as a study-adjusted inferential model rather than a design law. Overall R2 = 0.905, adjusted R2 = 0.893, within-study R2 = 0.703, residual standard deviation (SD) = 0.130, and variance inflation factors (VIFs) = 1.04–1.07 (Supplementary Table S11). Residual plots showed no systematic mean trend, although the Q-Q plot had some upper-tail departure (Supplementary Figures S1–S3). Five observations exceeded Cook’s 4/n threshold, but deleting them individually kept βK = 0.259–0.273 and deleting all five gave βK = 0.272 (Supplementary Figure S4).

3.3. Axial-Stiffness Representation and Residual Material Effects

The central question is not whether Kl influences shear strength, but whether the reinforcement ratio and elastic modulus can be represented by their common product ρE across steel and GFRP. In the full 82-beam core, relaxing the equal-exponent restriction gave an exponent-asymmetry estimate δ = 0.078 (95% CI 0.016 to 0.139). The unrestricted model reduced AIC by 22.00 and the conventional six-cluster test gave p = 0.023. Taken alone, this result would suggest that the reinforcement ratio and modulus do not act through an exactly common exponent.
With only six independent experimental programs, the conventional result should be treated cautiously [32,33,34]. The 64-pattern Rademacher wild-cluster sign-flip sensitivity gave p = 0.25 (Table 6; Figure 3), so the apparent departure from δ = 0 is not stable under the few-study check. This does not show that δ is zero: the reference distribution is coarse, with a minimum attainable non-zero two-sided p-value of 0.03125. The data therefore do not support a transferable unequal-exponent correction across studies, but they also do not demonstrate exact axial-stiffness equivalence.
Table 6. Robustness of the equal-exponent restriction and residual material-effect tests.
Figure 3. Robustness of the exponent-asymmetry test of the equal-exponent restriction.
In the 63-beam configuration subset, δ fell to 0.015 (95% CI −0.075 to 0.105), the conventional cluster p-value rose to 0.667, and the fully enumerated sign-flip p-value was 0.8125. The unequal-exponent specification is now penalized rather than favored in sample (ΔAIC = −1.36), so once every source-reported two-layer specimen is removed the data give no in-sample support for relaxing the equal-exponent restriction. Removing A4.2, the yielded specimens, both, or Alam did not change that. Because the subset contains five programs, its minimum non-zero enumerated p-value is 0.0625, and the further Alam-excluded case has four programs and a floor of 0.125; neither can attain p < 0.05 regardless of effect size.
The categorical diagnostic showed the same domain dependence. The full core gave an apparent +26.6% GFRP effect (95% CI +7.4% to +49.2%; ΔAIC = 22.73), with a fully enumerated sign-flip p-value of 0.1875. In the configuration subset, the estimate fell to +5.3% (95% CI −17.9% to +35.1%), ΔAIC = −1.17, and the fully enumerated sign-flip p-value was 0.8125 (Figure 4; Table 6). Because no formal equivalence margin was prespecified [35], these results neither prove equality nor support a stable universal material correction. As noted in Section 2.5, δ and the categorical GFRP term are near-collinear in this database, so the two sets of columns in Table 6 should not be read as independent confirmation of one another.
Figure 4. Sensitivity of the residual GFRP effect across analysis scenarios.
This sensitivity is mechanically plausible because equal Kl does not imply equal reinforcement geometry. Owing to the lower elastic modulus of GFRP, matching ρE usually requires a larger reinforcement area. Changes in bar area, number of bars, perimeter, spacing, and vertical layer position can affect crack spacing, longitudinal-strain gradients, bond demand, and dowel engagement [36,37] even when the scalar product ρE is similar. Experimental studies have identified the reinforcement amount, crack response, and bar arrangement as relevant to shear behavior [3,4,5,14,23,26,38]. A categorical GFRP coefficient can therefore absorb configuration and product effects that are correlated with material identity rather than caused by material identity alone.
The Halvonik two-layer beams deserve separate attention because layering and common support overlap in that program. A7 was intentionally detailed with two steel layers, while the higher-ratio GFRP series B5/B6 also required two layers; total depth was increased so that d remained 100 mm. Halvonik et al. identified unusually high responses for B5.2b, B6.1a, and B6.2a and linked them to the two-layer GFRP arrangement; their steel series also showed a beneficial two-layer response for A7. This supports treating reinforcement layout as a sensitivity condition. At the same time, the four Halvonik GFRP beams that overlap the steel Kl range are the B5/B6 two-layer beams. Removing them therefore changes configuration and material overlap together. The resulting reductions in δ and the GFRP coefficient cannot be assigned to layering alone.
Common-support restriction does not make the material effect smaller. In the pooled interval, where steel and GFRP are most comparable in Kl, the residual GFRP estimate rises to +31.3%, with conventional cluster p = 0.001 and a large AIC improvement (Table 6). Yet the six-study sign-flip sensitivity gives p = 0.0625. The +5.3% estimate from the configuration subset was obtained without within-program steel–GFRP common support, so its material-effect interpretation relies on the assumed regression form. In this database, better Kl comparability and cleaner configuration control point in different directions, so their effects cannot be separated.
Program deletion makes this dependence especially clear. Removing Halvonik et al. reduces δ from 0.078 to 0.032 and the residual GFRP effect from +26.6% to +11.2% in the strict core. In pooled common support, the corresponding changes are 0.091 to 0.054 and +31.3% to +19.2%. Removing any other program leaves the strict-core GFRP estimate between +24.6% and +30.6% and the pooled-support estimate between +29.9% and +35.9%. The large material coefficient is therefore carried mainly by the Halvonik program (Figure 5). The present data cannot determine whether that leverage reflects material, the two-layer layout, or their coincidence, but it does not justify a universal +30% GFRP correction.
Figure 5. Leave-one-program-out leverage on the residual GFRP effect. Yost et al. [6], Tureyen & Frosch [7], Tariq & Newhook [27], El-Sayed et al. [8,28], Alam & Hussein [20], and Halvonik et al. [21].
The uncertain arrangements do not change this picture. Removing the six specimens whose reported reinforcement implies more than one layer gave δ = 0.022 (95% CI −0.058 to 0.102) and a residual GFRP effect of +7.2% (−13.8% to +33.4%), with sign-flip p = 0.75 for both and negative ΔAIC values (Table 6). Retaining only the 45 explicitly single-layer specimens gave δ = 0.030 (−0.065 to 0.126) and +9.5% (−16.5% to +43.6%), with ΔAIC values of 0.21 and 0.37. The point estimates move modestly upward as the subset narrows, but all intervals include zero and none of the in-sample criteria favors a material-sensitive extension. The residual material effect in configuration-controlled data is therefore small and imprecisely estimated whichever way the unreported arrangements are treated.
In practical terms, the existing database can answer the general question of whether shear strength increases with Kl, and it shows that it does at a stable rate across programs. It cannot answer whether GFRP needs its own correction, because the apparent GFRP signal in the full core comes mainly from the Halvonik program. That program contributes most of the directly comparable steel–GFRP beams, and its highest GFRP responses coincide with two-layer arrangements. Any material coefficient fitted to the full core would therefore largely restate one laboratory’s result, and it would be unsafe to transfer it to members with different reinforcement layouts, depths, or concrete. A credible material correction, if one exists, will require several independent programs with matched Kl and controlled layering.
The a/d threshold sensitivity tested whether the principal conclusion depended on the strict core cutoff. Adding 14 rectangular beams with a/d approximately 2.4–2.43 increased the database to 96 beams and produced larger point estimates: δ = 0.080 and an apparent GFRP effect of +28.0%. Yet the fully enumerated seven-program sign-flip p-values were 0.0625 for both δ and the material term. The signal therefore strengthened descriptively as the database moved toward the range in which arching action becomes more important [39,40], but it still did not provide robust few-study evidence for a universal material correction.
When every source-reported two-layer configuration and the two shear-flexural near-threshold cases were also excluded, the cleaner 75-beam sensitivity gave δ = 0.029 and a residual GFRP effect of +10.7%, with a fully enumerated sign-flip p-value of 0.4375 for both. This pattern is compatible with sensitivity to shear slenderness and reinforcement configuration, whose separate contributions are not identified by these subset comparisons. It also shows that the central interpretation is not an artifact of choosing a/d = 2.5 as the strict-core boundary.

3.4. Cross-Study and External Transferability

For the 82-beam core, LOSO evidence was mixed. Kl-only had the lowest MAPE (19.43% versus 19.78% for separate ρ/E and 19.87% for +GFRP) and the highest ±20% coverage, whereas the extensions had slightly lower RMSE (0.290 versus 0.302 MPa) and higher ±30% coverage (Table 7). Thus, no full-core model dominated across metrics.
Table 7. Leave-one-study-out prediction metrics. Panel A: overall metrics by model; Panel B: error distribution by material.
The 63-beam configuration subset gives a sharper descriptive parsimony result. Here, the Kl-only model produced an overall mean Vexp/Vpred ratio of 0.968, MAPE = 16.56%, and RMSE = 0.193 MPa. Separating ρ and E increased MAPE to 17.67% and RMSE to 0.210 MPa, while adding a categorical GFRP indicator increased MAPE to 17.96% and RMSE to 0.214 MPa. In the configuration subset, the Kl-only model achieved the lowest MAPE and RMSE and the highest ±20% coverage, whereas the separate ρ/E model achieved the highest ±30% coverage (90.5% versus 88.9% for the Kl-only model; Table 7). The evidence against additional material-sensitive complexity is strongest in this configuration-controlled domain, not in the full 82-beam core.
Because the MAPE differences among model forms are small, their uncertainty was assessed at the level of experimental programs. A program-level bootstrap of the held-out predictions (10,000 resamples of complete programs) yielded a MAPE difference (extension minus Kl-only) of +0.35 percentage points (95% interval −0.43 to +1.54) for the separate ρ/E model and +0.44 (−0.44 to +1.86) for the GFRP-indicator model in the full core, and +1.12 (−0.33 to +2.83) and +1.41 (−0.17 to +3.23) in the configuration subset (Supplementary Table S12). Every interval includes zero. The Kl-only model is therefore the more parsimonious choice without loss of accuracy, yet the data do not establish that it is more accurate. The ranking of model forms should be read as a descriptive result rather than as a statistically meaningful difference.
The distribution of held-out errors is summarized in Table 7, Panel B and Figure 6a. For the full core, the Kl-only model gave a mean Vexp/Vpred of 1.001 but a median of 0.937, a coefficient of variation (CoV) of 25.6%, and a 5th–95th percentile range of 0.71–1.55. Of the beams, 64.6% were overpredicted (Vexp/Vpred < 1), and the mean is pulled upward by a smaller number of strongly underpredicted beams. Performance was nearly identical for the two materials: mean Vexp/Vpred = 0.998 for steel and 1.003 for GFRP, CoV = 25.7% for both, and MAPE = 19.5% and 19.3%. In the configuration subset the GFRP errors exceeded the steel errors (MAPE 18.3% versus 14.0%; CoV 23.4% versus 16.6%), but the GFRP-indicator model did not reduce them (Supplementary Table S13). The difference therefore reflects the programs in which GFRP specimens predominate rather than a correctable material offset. By program, mean Vexp/Vpred ranged from 0.71 (Alam and Hussein, all beams overpredicted) and 0.82 (Yost et al.) to 1.26 (Tariq and Newhook) and 1.34 (El-Sayed et al.), confirming that the dominant error component is a program-level offset. Applying fold-specific smearing factors shifted the mean ratios by about 1% and left the ordering of the three model forms unchanged on MAPE (Supplementary Table S8).
Figure 6. Leave-one-study-out prediction: (a) experimental versus predicted nominal shear strength for the 82-beam core (Kl-only model; each program predicted from the other five; marker shape denotes material and color denotes program); (b) held-out-program MAPE for the three model forms in the 63-beam reinforcement-configuration subset. Yost et al. [6], Tureyen & Frosch [7], Tariq & Newhook [27], El-Sayed et al. [8,28], Alam & Hussein [20], and Halvonik et al. [21].
More importantly, differences among experimental programs were much larger than differences among model forms. Held-out-study MAPE for the Kl-only formulation ranged from 6.4% for Halvonik et al. to 38.9% for Alam and Hussein, with intermediate values of 9.7% for Tureyen and Frosch, 19.4% for Yost et al., and 19.6% for Tariq and Newhook (Figure 6b, Supplementary Table S14); El-Sayed et al. does not appear because its specimens are all source-reported two-layer. Such variation can arise from concrete mixture, aggregate characteristics, loading configuration, reinforcement product, bond surface, measurement convention, or failure classification [41,42]. These program-level effects are substantially larger than the predictive gain of either candidate material correction.
This result is methodologically important for shear databases. Random specimen splits would allow beams from the same experimental program to appear in both calibration and validation sets, masking study-specific offsets and overstating transferability [43,44]. The present LOSO procedure is stricter in two respects: a complete program is withheld, and the prediction fit contains no program-specific intercepts at all. Each held-out program is therefore predicted with the common intercept and slopes learned from the other programs under equal total training weight per study. The resulting error includes both imperfect transfer of the physical slopes and any unmodeled baseline shift of the unseen laboratory; this is intentional because such a shift is unavailable in genuine prospective prediction. On that criterion, no formulation dominates the predefined 82-beam core across all metrics, while the simpler Kl representation is the most accurate on every metric in the configuration-controlled subset.
The external T-section program provides a conceptually different transfer test because both material and section geometry are present outside the rectangular calibration domain [22]; flange geometry is itself known to influence shear transfer [45]. Without refitting or introducing a T-section correction, the core Kl model predicted the 29 T-section beams with an overall mean Vexp/Vpred ratio of 0.853, MAPE = 19.44%, and RMSE = 0.168 MPa; all 29 predictions were within ±30% (Figure 7; Table 8). Mean Vexp/Vpred was 0.838 for steel and 0.865 for GFRP, with corresponding MAPE values of 21.25% and 17.97%. Training the same model on the 63-beam configuration subset instead raises the overall MAPE to 32.86%, because that subset retains only four specimens near the effective depth of the T-section beams; the material comparison below is unchanged by the choice.
Figure 7. External T-section predictions from the rectangular core Kl model. Dashed lines show the mean Vexp/Vpred of each material; their near coincidence indicates a shared program-level offset.
Table 8. External T-section validation metrics.
The external T-section results show little evidence of a material-specific transfer error. The descriptive within-program residual GFRP difference was +3.3% (95% CI −5.5% to +13.0%; conventional beam-level p = 0.455), while the ρ/E and GFRP-indicator extensions increased the overall MAPE to 21.92% and 22.73%. Steel and GFRP therefore shifted in nearly the same direction when the rectangular-beam model was applied to T-sections. The shared overprediction is compatible with section geometry or program-specific conditions, which cannot be separated in this single external program [46,47], in line with the critical-shear-crack interpretation discussed for this program [22].
A flange changes the shear-resisting mechanisms mainly through the compression chord. It enlarges the uncracked compression zone, allows the critical shear crack to extend into the flange so that part of the shear is carried there, and modifies the crack inclination and the location of the critical section [45,46,47]. These effects generally increase shear capacity relative to a rectangular web of the same width, so a rectangular model normalized by bwd would be expected to underpredict T-sections. The observed overprediction of about 15% for both materials therefore cannot be explained by the flange contribution alone. Other conditions of the T-section program must contribute, such as its concrete, its narrow web (bw = 150 mm), and its loading and measurement conventions. Because a material-specific source would shift steel and GFRP by different amounts, whereas the mean offsets here are 0.838 and 0.865 and differ by only +3.3% (95% CI −5.5% to +13.0%), the shared bias points to geometry or laboratory conditions rather than to the reinforcement material (Figure 7).
The two methodological choices that separate this analysis from pooled database practice can be quantified directly on the present core. Table 9 reports the same two material-sensitive terms under three inference treatments. Pooling the 82 beams and treating them as independent observations gives δ = 0.068 and a residual GFRP effect of +22.4%, both with beam-level p < 0.001. Introducing study fixed effects and clustering by experimental program leaves the point estimates almost unchanged, at 0.078 and +26.6%, but widens the intervals so that conventional significance becomes marginal, and the fully enumerated sign-flip sensitivity then returns p = 0.25 and 0.1875. Ignoring study structure therefore changed the point estimates little but markedly narrowed the uncertainty; the principal consequence of beam-level pooling in this dataset was overstated precision rather than a large shift in the fitted material coefficients. The same applies to validation design: random ten-fold splitting of the configuration subset gives a mean absolute percentage error of 10.3%, against 16.6% when a complete program is held out, so random splitting understates prediction error for an unseen laboratory about 38% (MAPE 10.3% versus 16.6%; equivalently, the held-out error is about 1.6 times the random-split error). Both comparisons are descriptive rather than inferential, but they indicate that beam-level significance and random-split accuracy are not safe summaries of cross-study evidence in databases with this structure.
Table 9. Apparent evidence for material-sensitive terms under three inference treatments, strict 82-beam core.
The pooled OLS rows use ordinary least squares on all 82 beams with no study effects and conventional beam-level degrees of freedom (df = 76); the study-aware rows are the models reported in Table 6. Dashes indicate that the sign-flip procedure returns a p-value for the restriction rather than a point estimate.
When a shear database combines specimens from a few laboratories, the laboratory, not the beam, should be the unit of replication. In practice this means fitting program effects or clustering by program, using inference that remains valid with few clusters, and validating by withholding complete programs. Beam-level p-values and random-split accuracies should not be reported as evidence of transferability, because in the present data they overstate precision and understate error for a new laboratory.

3.5. Stiffness-Matched Comparison and Implications for Shear Modeling

The deliberately stiffness-matched comparison in the Tureyen and Frosch program offers a transparent specimen-level check that does not rely on cross-study adjustment. Steel specimen V-D-2 had Kl = 719.8 MPa and GFRP specimen V-G2-2 had Kl = 721.5 MPa, a difference of only 0.23% (Table 10), yet their normalized responses vu/√f′c differed by approximately 14.7%. In contrast, GFRP specimen V-G1-2 had Kl = 778.4 MPa, about 8.1% above V-D-2, but its normalized response was only about 3.3% higher. V-D-2 also experienced steel yielding together with diagonal-tension failure, which cautions against treating any one pair as definitive evidence of exact equivalence. Removing V-D-2 from the broader analysis did not change the central inference. Panel B of Table 10 shows what equal Kl does and does not equalize. The cracked-section neutral-axis depth ratio, which depends on the reinforcement only through ρE, is practically identical for V-D-2 and V-G2-2 (0.193 and 0.195). In contrast, V-G2-2 carries 5.3 times the bar area of V-D-2, in two layers rather than one, with a correspondingly larger bar perimeter and dowel cross-section. The 14.7% higher normalized response of V-G2-2 occurs with different reinforcement quantities and arrangements, despite nearly equal calculated cracked-elastic neutral-axis depths. This comparison is consistent with the configuration effects discussed in Section 3.3; it does not establish equal compression-zone depths at failure, particularly because V-D-2 experienced steel yielding.
Table 10. Stiffness-matched comparison within the Tureyen and Frosch program. Panel A: normalized response; Panel B: reinforcement and section details.
V-D-2 is best regarded as a boundary case of the core rather than as an ordinary member of it. It meets every inclusion criterion and fails in diagonal tension, but its steel yielded at failure. It is also the only steel specimen deliberately matched to GFRP in Kl, and it has the lowest steel reinforcement ratio in the database (0.36%). Statistically it is not unusual: its residual in the primary model is −0.004 on the log scale, and its held-out prediction ratio is 0.958. Removing this single physical specimen leaves βK unchanged at 0.265. It raises δ from 0.078 to 0.088 and the residual GFRP effect from +26.6% to +29.8%, with sign-flip p-values of 0.28 and 0.25, and it leaves the ordering of the LOSO model forms unchanged (MAPE 19.57%, 19.75%, and 19.82%). Removing it together with the second yielding specimen, El-Sayed SN-0.9, corresponds to the “Strict core − yielded” row of Table 6. By comparison, removing the author-flagged Halvonik outlier A4.2 changes δ only to 0.079 and the GFRP effect to +27.2%. No single specimen therefore alters the pattern of results. Because V-D-2 lies at the lower edge of steel common support, its removal slightly enlarges the apparent full-core material effect, which is the expected direction when the only matched steel comparator is withdrawn.
The matched Tureyen–Frosch comparison helps place the database results in context. Here, calling Kl = ρE “material-neutral” does not mean that steel and GFRP have identical crack patterns, bond response, dowel action, or deformation [48,49]. It means that Kl works as a useful first-order reinforcement descriptor and that a material indicator has not improved predictive transfer consistently. This is compatible with stiffness-based treatments [9,10], while leaving room for models that retain additional mechanical variables [50,51], including compression-zone shear models [11] and recent strain-based approaches [25].
The mechanical basis of this interpretation can be stated more precisely. The reinforcement ratio and the elastic modulus influence one-way shear resistance through partly different mechanisms. The modulus governs the reinforcement strain at a given force and therefore the crack opening, the longitudinal strain at the critical section, and the depth of the uncracked compression zone; in the cracked-elastic idealization, the neutral-axis depth depends on the reinforcement only through ρE/Ec, which is the mechanical reason why Kl enters strain-based and compression-zone shear models [9,10,11,25]. The reinforcement ratio, by contrast, is realized through a particular number, diameter, and arrangement of bars, which determine the total bar perimeter available for bond, the crack spacing, and the dowel cross-section and its transverse stiffness [36,37,48]. Because the GFRP modulus is roughly one-fifth that of steel, matching Kl requires about five times the bar area, so matched-Kl GFRP specimens necessarily differ from their steel companions in bar number or diameter, perimeter, and often layering. Kl can therefore represent the compression-zone and strain-controlled crack-opening contributions to first order, but it cannot represent differences in bond, crack spacing, and dowel action that follow from the different bar quantity and arrangement. The source observations agree with this reading. All core specimens of both materials failed in diagonal tension or shear (with the two flagged yielding cases), so the nominal failure mode does not discriminate between materials; Yost et al. attributed the lower capacity of GFRP-reinforced beams to wider cracks, a smaller compression block, and reduced dowel action [6]; El-Sayed et al. attributed the reduced shear strength to the low modulus of the FRP bars [8]; and Halvonik et al. reported a larger shear gain per unit increase in Kl for GFRP than for steel and linked the highest GFRP responses to two-layer arrangements [21]. As noted in Section 2.5, the database cannot separate these mechanisms statistically, because 99.98% of the within-study variance in ln E lies between the steel and GFRP groups; the exponent-asymmetry and GFRP terms are therefore summaries of the combined steel–GFRP contrast and not estimates of separate ρ and E mechanisms. Accordingly, the finding that material-sensitive models did not provide a consistent predictive advantage is evidence about the statistical sufficiency of Kl as a first-order predictor in this domain; it is not evidence that steel- and GFRP-reinforced members share the same crack patterns, deformations, or distribution of shear-transfer actions.
For design-oriented modeling, added terms should be retained only when they provide stable and independently validated predictive improvements. If a shear model already includes longitudinal reinforcement stiffness, member size, concrete strength, and shear-span geometry, a GFRP multiplier should not be added solely because it improves a pooled fit [52,53]. It should remain stable across reinforcement configurations and improve prediction in independent programs. The coefficient was unstable, and predictive improvement was not consistent across datasets and metrics. This conclusion does not replace or challenge the FRP design provisions [16,17], which include safety formats and FRP-specific design considerations outside the scope of the present regression analysis. Related investigations of steel-reinforced concrete members have also examined the contribution of embedded steel to joint-panel shear under cyclic loading [54]. While the loading regime, member type, and resisting mechanisms differ from those of the slender stirrupless beams considered here, the work underscores the sensitivity of shear transfer to the presence and detailing of steel.

3.6. Limitations and Research Needs

The main limitation is the restricted within-program overlap in steel–GFRP Kl, which constrains separation of material and reinforcement-layout effects; inference therefore remains conditional on the sampled programs and covariate ranges. The small number of independent programs, reconstructed or assumed inputs, and the single T-section validation program further bound generalization. Future studies should prioritize matched-Kl comparisons under controlled geometry, concrete, and loading conditions, with systematic variation in the reinforcement ratio and layer arrangement. Coordinated measurements of crack development, bar strain, and bond–slip response across independent laboratories would strengthen mechanistic interpretation and establish broader applicability.
Three further limitations follow from the database design. First, the core was not expanded beyond the six paired programs, because additional eligible paired steel–GFRP programs were not identified under the stated criteria (Section 2.1; Supplementary Table S1); any future expansion would require all analyses to be repeated, and the present estimates should be regarded as provisional with respect to new programs. Second, the analysis is restricted to steel and GFRP; whether Kl represents CFRP, AFRP, or BFRP reinforcement equally well was not tested, and such a test would require programs that include more than one FRP type together with steel companions. Third, the layer arrangement of 18 core specimens is not reported in their sources; the arrangement sensitivities in Section 3.3 bound, but do not remove, this uncertainty. For design application, Kl is supported only as a first-order statistical descriptor within the studied domain; it is not a substitute for the FRP-specific provisions and safety formats of the governing codes [16,17].
Whether the findings extend to other FRP bars can only be anticipated. For CFRP products whose elastic modulus is closer to that of steel than that of the GFRP bars considered here, matching Kl at the same section geometry would require more similar reinforcement areas. This could reduce differences in bar quantity and layering and may favor transferability of the Kl representation, although this remains a hypothesis requiring experimental verification. AFRP and BFRP bar properties depend on the particular product, and differences in the elastic modulus, surface treatment, bond, and transverse stiffness may affect shear behavior; a larger size effect has been reported for BFRP-reinforced beams [3]. For these materials, the present conclusion that Kl is a sufficient first-order descriptor should not be assumed without testing. Verification would require purpose-designed programs in which, within one laboratory, steel, GFRP, and one alternative FRP are tested at matched Kl with the same number of bars and a single layer wherever possible, at two or more effective depths and with replicates. Crack kinematics, bar strains, and dowel displacements should be measured so that the stiffness-related and bond-related contributions can be separated.

4. Conclusions

Within the slender, stirrupless domain examined in this study, Kl = ρE provided a parsimonious first-order representation of longitudinal reinforcement effects, and the material-sensitive extensions did not show a consistent transferable predictive advantage. Limited within-program common support and sensitivity to individual experimental programs nevertheless prevent this finding from being interpreted as proof of strict material neutrality. Where material-specific treatment is required, the present results suggest that reinforcement configuration and associated mechanics should be considered explicitly rather than represented by a universal categorical multiplier fitted to pooled data. These conclusions are based on an 82-beam, six-program core, targeted sensitivity analyses, leave-one-study-out validation, and external T-section transfer assessment.
  • Longitudinal axial stiffness was a positive within-program predictor with stable estimates across program deletions. The full-core estimate was βK = 0.265 and remained 0.245–0.284 across whole-program deletions. By contrast, the fitted d and a/d coefficients were strongly program-dependent and are best treated as adjustment controls rather than transferable exponents.
  • Direct material identification remains limited: four of six programs have disjoint steel–GFRP Kl ranges, only 17/82 beams lie in study-specific common support, and no within-program steel–GFRP common support remains in the 63-beam configuration subset. Whole-program deletion also exposed strong study leverage: excluding Halvonik reduced the strict-core δ from 0.078 to 0.032 and the residual GFRP effect from +26.6% to +11.2%; in pooled common support, the corresponding estimates fell from 0.091 to 0.054 and from +31.3% to +19.2%. Non-rejection in the fully enumerated few-cluster sign-flip sensitivity cannot be interpreted as material equality, while the large pooled material coefficient is not stable enough to support a transferable GFRP correction. Because δ and the GFRP term are correlated at 0.997 after adjustment, they constitute one material diagnostic rather than two.
  • Reinforcement configuration is a plausible boundary condition, but it is partly confounded with material common support. In the 63-beam configuration subset, which removes every specimen its source reports as two-layer, δ was 0.015 and the residual GFRP effect +5.3% (95% CI −17.9% to +35.1%), and AIC favored neither extension. Excluding six specimens whose geometry implies an unreported multilayer arrangement gave +7.2% (95% CI −13.8% to +33.4%), and retaining only explicitly single-layer specimens gave +9.5% (−16.5% to +43.6%). Because forming this subset changes both reinforcement arrangement and material common support, and because two programs covering 18 core specimens do not report the arrangement at all, the smaller estimates cannot be attributed uniquely to layering.
  • The principal interpretation was not sensitive to the a/d = 2.5 cutoff. Near-threshold analyses increased the apparent material effects descriptively, but the fully enumerated few-cluster sign-flip sensitivity remained non-robust; the configuration-controlled, shear-only 75-beam sensitivity gave δ = 0.029 and a residual GFRP effect of +10.7% (sign-flip p = 0.4375).
  • Predictive transferability did not support additional material-sensitive complexity. Full-core LOSO performance was metric-dependent; in the configuration-controlled subset, the Kl-only model gave the lowest MAPE and RMSE and the highest ±20% coverage, whereas the separate ρ/E model gave the highest ±30% coverage. External prediction of 29 T-section beams also favored the simpler model descriptively: steel and GFRP showed similar residual bias, the residual material difference was +3.3% (p = 0.455), and the material-sensitive extensions increased prediction error. Program-level bootstrap intervals for the MAPE differences between model forms all included zero, so the advantage of the simpler model is one of parsimony rather than demonstrated accuracy; held-out errors had a CoV of about 25% and were dominated by program-level offsets.
Accordingly, Kl = ρE is supported as a parsimonious first-order predictor within the studied slender, stirrupless domain, while neither strict material neutrality nor a universal GFRP-specific multiplier is established. Purpose-designed, replicated matched-stiffness experiments are needed to separate material from reinforcement configuration. The statistical usefulness of Kl as a first-order predictor should not be read as evidence of equivalent shear behavior of steel- and GFRP-reinforced members, nor as a replacement for FRP-specific design provisions.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/buildings16234732/s1. File S1 (PDF): Supplementary Information, containing Tables S1–S14 and Figures S1–S4. Table S1: Sequential database screening criteria and their consequences; Table S2: Datasets represented in the supplementary workbook; Table S3: Mutually exclusive source-provenance categories of the strict core; Table S4: Fixed reference values used to express the logarithmic predictors; Table S5: Sensitivity of material diagnostics to the treatment of unreported reinforcement arrangements; Table S6: Fully enumerated sign-flip exceedance counts and p-values; Table S7: Selected elements of the LOSO prediction protocol; Table S8: Leave-one-study-out metrics without and with a fold-specific smearing retransformation correction; Table S9: Location of supporting information in the 26-sheet workbook; Table S10: Whole-program deletion sensitivity of material-related estimates; Table S11: Selected primary-model diagnostic quantities; Table S12: Program-level bootstrap of differences in held-out MAPE between model forms (10,000 resamples of complete programs); Table S13: Leave-one-study-out errors by held-out program (82-beam core) and by material (core and 63-beam subset); Table S14: Held-out-program predictions from the Kl-only model on the 63-beam reinforcement-configuration subset; Figure S1: Residuals versus fitted ln(vu); Figure S2: Residuals versus ln(d/100); Figure S3: Normal Q–Q plot of studentized residuals; Figure S4: Cook’s distance by observation, including the 4/n reference line.

Author Contributions

Conceptualization, N.M.A. and Y.G.E.; methodology, A.F. and A.A.; software, N.M.A., A.A. and A.F.; validation, N.M.A., Y.G.E. and A.F.; formal analysis, A.F., N.M.A. and Y.G.E.; investigation, A.F., A.A. and N.M.A.; resources, Y.G.E.; data curation, N.M.A. and A.F.; writing—original draft preparation, N.M.A. and A.F.; writing—review and editing, A.F., A.A., Y.G.E. and N.M.A.; visualization, N.M.A., A.A. and A.F.; supervision, A.F. and Y.G.E.; project administration, N.M.A.; funding acquisition, Y.G.E. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Deanship of Postgraduate Studies and Scientific Research at Majmaah University (R-2026-561).

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The Supplementary File contains the data and analyses supporting this study, including source provenance, specimen-level records, reported reinforcement arrangements or explicit identification of missing information, derived variables, statistical and prediction methods, model diagnostics, sensitivity analyses, prediction summaries, and numerical figure data. It covers the 82-beam strict rectangular core, 14 near-threshold specimens, and 29 external T-section beams. Supplementary Figures S1–S4 are included in the Supplementary Information File.

Acknowledgments

The authors extend the appreciation to the Deanship of Postgraduate Studies and Scientific Research at Majmaah University for funding this research work through the project number (R-2026-561).

Conflicts of Interest

The authors declare no conflicts of interest.

Nomenclature

a/dshear-span-to-effective-depth ratio
Alarea of longitudinal tensile reinforcement
bwweb width
deffective depth
Eelastic modulus of the longitudinal reinforcement
f′cconcrete cylinder compressive strength
Klnormalized longitudinal axial stiffness, ρE
vunominal shear strength, Vu/(bw d)
Vuexperimental shear force at failure
αjprogram-specific intercept for experimental program j
βK, βc, βd, βa/dfitted exponents on Kl, f′c, d, and a/d
η0baseline linear predictor from Equation (4), excluding ε
IGFRPbinary material indicator (1 = GFRP; 0 = steel)
εwithin-study residual
γcategorical GFRP coefficient (material-identity diagnostic)
δexponent-asymmetry parameter; δ = 0 denotes the equal-exponent restriction
ρlongitudinal reinforcement ratio, Al/(bw d)
AICAkaike information criterion
LOSOleave-one-study-out
MAPEmean absolute percentage error
RMSEroot-mean-square error
VIFvariance inflation factor

References

  1. Szinvai, S.; Kovács, T. The challenges of GFRP RC beam design for limit states. Struct. Concr. 2026, 27, 7635–7653. [Google Scholar] [CrossRef] [Scilit]
  2. Gao, D.; Zhang, C. Shear strength calculating model of FRP bar reinforced concrete beams without stirrups. Eng. Struct. 2020, 221, 111025. [Google Scholar] [CrossRef] [Scilit]
  3. Jumaa, G.B.; Yousif, A.R. Size Effect in Shear Failure of High Strength Concrete Beams without Stirrup reinforced with Basalt FRP Bars. KSCE J. Civ. Eng. 2019, 23, 1636–1650. [Google Scholar] [CrossRef] [Scilit]
  4. Elghandour, B.; Eltahawy, R.; Shedid, M.; Abdelrahman, A. Prediction of shear strength for CFRP reinforced concrete beams without stirrups. Eng. Struct. 2023, 284, 115946. [Google Scholar] [CrossRef] [Scilit]
  5. Abdul-Salam, B.; Farghaly, A.S.; Benmokrane, B. Mechanisms of shear resistance of one-way concrete slabs reinforced with FRP bars. Constr. Build. Mater. 2016, 127, 959–970. [Google Scholar] [CrossRef] [Scilit]
  6. Yost, J.R.; Gross, S.P.; Dinehart, D.W. Shear Strength of Normal Strength Concrete Beams Reinforced with Deformed GFRP Bars. J. Compos. Constr. 2001, 5, 268–275. [Google Scholar] [CrossRef] [Scilit]
  7. Tureyen, A.K.; Frosch, R.J. Shear Tests of FRP-Reinforced Concrete Beams without Stirrups. ACI Struct. J. 2002, 99, 427–434. [Google Scholar] [CrossRef] [Scilit]
  8. El-Sayed, A.K.; El-Salakawy, E.F.; Benmokrane, B. Shear Strength of FRP-Reinforced Concrete Beams without Transverse Reinforcement. ACI Struct. J. 2006, 103, 235–243. [Google Scholar] [CrossRef] [Scilit]
  9. Baghi, H.; Barros, J.A.O.; Kaszubska, M.; Kotynia, R. Shear behavior of concrete beams reinforced exclusively with longitudinal glass fiber reinforced polymer bars: Analytical model. Struct. Concr. 2018, 19, 162–173. [Google Scholar] [CrossRef] [Scilit]
  10. Razaqpur, A.G.; Spadea, S. Shear Strength of FRP Reinforced Concrete Members with Stirrups. J. Compos. Constr. 2015, 19, 04014025. [Google Scholar] [CrossRef] [Scilit]
  11. Dinh, N.H.; Roh, Y.-S.; Truong, G.T. Shear strength model of FRP-reinforced concrete beams without shear reinforcement. Structures 2024, 64, 106520. [Google Scholar] [CrossRef] [Scilit]
  12. Gao, D.; Zhang, C. A Model for Shear Strength of FRP Bar Reinforced Concrete Beams without Stirrups. Adv. Civ. Eng. 2020, 2020, 8881463. [Google Scholar] [CrossRef] [Scilit]
  13. Tarawneh, A.; Saleh, E.; Alghossoon, A.; Naser, M.Z. Proposing a one-way shear design model for FRP-RC members: Evaluation and reliability calibration. Eng. Struct. 2023, 292, 116527. [Google Scholar] [CrossRef] [Scilit]
  14. Alguhi, H.; Tomlinson, D.G. One-Way Shear Strength of FRP–Reinforced Concrete Members Without Stirrups: Design Provision Review. J. Compos. Constr. 2021, 25, 04021016. [Google Scholar] [CrossRef] [Scilit]
  15. Ali, A.H.; Mohamed, H.M.; Chalioris, C.E.; Deifalla, A.F. Evaluating the shear design equations of FRP-reinforced concrete beams without shear reinforcement. Eng. Struct. 2021, 235, 112017. [Google Scholar] [CrossRef] [Scilit]
  16. ACI Committee 440. Building Code Requirements for Structural Concrete Reinforced with Glass Fiber-Reinforced Polymer (GFRP) Bars—Code and Commentary (ACI CODE-440.11-22); American Concrete Institute: Farmington Hills, MI, USA, 2022. [Google Scholar]
  17. CSA Group. Design and Construction of Building Structures with Fibre-Reinforced Polymers (CSA S806-12, Reaffirmed 2021); Canadian Standards Association: Toronto, ON, Canada, 2021. [Google Scholar]
  18. Nasrollahzadeh, K.; Aghamohammadi, R. Reliability analysis of shear strength provisions for FRP-reinforced concrete beams. Eng. Struct. 2018, 176, 785–800. [Google Scholar] [CrossRef] [Scilit]
  19. Dinh, N.H.; Kim, S.-H.; Choi, K.-K. Evaluation of KDS 14 Draft Model for One-Way Shear Strength of Slender Concrete Members Reinforced with Fiber-Reinforced Polymer (FRP) Rebars. Int. J. Concr. Struct. Mater. 2025, 19, 63. [Google Scholar] [CrossRef] [Scilit]
  20. Alam, M.S.; Hussein, A. Size Effect on Shear Strength of FRP Reinforced Concrete Beams without Stirrups. J. Compos. Constr. 2013, 17, 507–516. [Google Scholar] [CrossRef] [Scilit]
  21. Halvoník, J.; Borzovič, V.; Lániová, D. Comparison of shear behaviour of concrete beams reinforced with GFRP bars and steel bars. Structures 2022, 43, 657–668. [Google Scholar] [CrossRef] [Scilit]
  22. Kaszubska, M.; Kotynia, R. Selected Shear Models Based on the Analysis of the Critical Shear Crack for Slender Concrete Beams without Shear Reinforcement. Materials 2022, 15, 8259. [Google Scholar] [CrossRef] [Scilit]
  23. Mistretta, F.; Puppio, M.L.; Camata, G.; Nanni, A. Analytical and experimental shear evaluation of GFRP-reinforced concrete beams. Mater. Struct. 2023, 56, 173. [Google Scholar] [CrossRef] [Scilit]
  24. Ahmed, Z.O.; Abdulrahman, A.S. Shear Performance of GFRP Reinforced Concrete Beams Without Transverse Reinforcement. Sulaimani J. Eng. Sci. 2026, 12, 75–95. [Google Scholar] [CrossRef] [Scilit]
  25. Dinh, N.H.; Pham, H.H.; Kim, S.-H.; Choi, K.-K. Strain-based analytical model for predicting one-way shear strength of slender FRP-reinforced concrete beams with and without transverse reinforcement. Compos. Struct. 2026, 389, 120404. [Google Scholar] [CrossRef] [Scilit]
  26. Krall, M.; Polak, M.A. Concrete beams with different arrangements of GFRP flexural and shear reinforcement. Eng. Struct. 2019, 198, 109333. [Google Scholar] [CrossRef] [Scilit]
  27. Tariq, M.; Newhook, J.P. Shear Testing of FRP Reinforced Concrete without Transverse Reinforcement. In Proceedings of the Annual Conference of the Canadian Society for Civil Engineering, Moncton, NB, Canada, 4–7 June 2003; pp. 1330–1339. [Google Scholar]
  28. El-Sayed, A.K.; El-Salakawy, E.F.; Benmokrane, B. Shear Capacity of High-Strength Concrete Beams Reinforced with Fiber-Reinforced Polymer Bars. ACI Struct. J. 2006, 103, 383–389. [Google Scholar] [CrossRef] [Scilit]
  29. Liang, X.; Peng, J.; Ren, R. A state-of-the-art review: Shear performance of the concrete beams reinforced with FRP bars. Constr. Build. Mater. 2023, 364, 129996. [Google Scholar] [CrossRef] [Scilit]
  30. Jumaa, G.B.; Yousif, A.R. Size effect on the shear failure of high-strength concrete beams reinforced with basalt FRP bars and stirrups. Constr. Build. Mater. 2019, 209, 77–94. [Google Scholar] [CrossRef] [Scilit]
  31. Jumaa, G.B.; Yousif, A.R. Numerical modeling of size effect in shear strength of FRP-reinforced concrete beams. Structures 2019, 20, 237–254. [Google Scholar] [CrossRef] [Scilit]
  32. Cameron, A.C.; Miller, D.L. A Practitioner’s Guide to Cluster-Robust Inference. J. Hum. Resour. 2015, 50, 317–372. [Google Scholar] [CrossRef] [Scilit]
  33. MacKinnon, J.G.; Nielsen, M.Ø.; Webb, M.D. Cluster-robust inference: A guide to empirical practice. J. Econom. 2023, 232, 272–299. [Google Scholar] [CrossRef] [Scilit]
  34. Canay, I.A.; Santos, A.; Shaikh, A.M. The Wild Bootstrap with a ‘Small’ Number of ‘Large’ Clusters. Rev. Econ. Stat. 2021, 103, 346–363. [Google Scholar] [CrossRef] [Scilit]
  35. Lakens, D. Equivalence Tests: A Practical Primer for t Tests, Correlations, and Meta-Analyses. Soc. Psychol. Personal. Sci. 2017, 8, 355–362. [Google Scholar] [CrossRef] [Scilit]
  36. Barris, C.; Torres, L.; Vilanova, I.; Miàs, C.; Llorens, M. Experimental study on crack width and crack spacing for Glass-FRP reinforced concrete beams. Eng. Struct. 2017, 131, 231–242. [Google Scholar] [CrossRef] [Scilit]
  37. Huber, P.; Huber, T.; Kollegger, J. Investigation of the shear behavior of RC beams on the basis of measured crack kinematics. Eng. Struct. 2016, 113, 41–58. [Google Scholar] [CrossRef] [Scilit]
  38. Imjai, T.; Guadagnini, M.; Garcia, R.; Pilakoutas, K. A practical method for determining shear crack induced deformation in FRP RC beams. Eng. Struct. 2016, 126, 353–364. [Google Scholar] [CrossRef] [Scilit]
  39. Peng, F.; Cai, Y.; Yi, W.; Xue, W. Shear behavior of two-span continuous concrete deep beams reinforced with GFRP bars. Eng. Struct. 2023, 290, 116367. [Google Scholar] [CrossRef] [Scilit]
  40. Li, Z.; Li, Y.; Yi, W.-J.; Huang, Y.; Zhou, Y.; Zhang, W.-X. Shear Mechanism and Size Effect of RC Deep Beams without Stirrups Based on Crack Kinematics in Tests. J. Struct. Eng. 2023, 149, 04023159. [Google Scholar] [CrossRef] [Scilit]
  41. Huber, T.; Huber, P.; Kollegger, J. Influence of aggregate interlock on the shear resistance of reinforced concrete beams without stirrups. Eng. Struct. 2019, 186, 26–42. [Google Scholar] [CrossRef] [Scilit]
  42. Montoya-Coronado, L.A.; Ribas, C.; Ruiz-Pinilla, J.G.; Cladera, A. Time-history analysis of aggregate interlock in reinforced concrete beams without stirrups. Eng. Struct. 2023, 283, 115912. [Google Scholar] [CrossRef] [Scilit]
  43. Roberts, D.R.; Bahn, V.; Ciuti, S.; Boyce, M.S.; Elith, J.; Guillera-Arroita, G.; Hauenstein, S.; Lahoz-Monfort, J.J.; Schröder, B.; Thuiller, W.; et al. Cross-validation strategies for data with temporal, spatial, hierarchical, or phylogenetic structure. Ecography 2017, 40, 913–929. [Google Scholar] [CrossRef] [Scilit]
  44. Wakjira, T.G.; Al-Hamrani, A.; Ebead, U.; Alnahhal, W. Shear capacity prediction of FRP-RC beams using single and ensenble ExPlainable Machine learning models. Compos. Struct. 2022, 287, 115381. [Google Scholar] [CrossRef] [Scilit]
  45. Ayensa, A.; Oller, E.; Beltrán, B.; Ibarz, E.; Marí, A.; Gracia, L. Influence of the flanges width and thickness on the shear strength of reinforced concrete beams with T-shaped cross section. Eng. Struct. 2019, 188, 506–518. [Google Scholar] [CrossRef] [Scilit]
  46. Cladera, A.; Marí, A.; Ribas, C.; Bairán, J.; Oller, E. Predicting the shear–flexural strength of slender reinforced concrete T and I shaped beams. Eng. Struct. 2015, 101, 386–398. [Google Scholar] [CrossRef] [Scilit]
  47. Ribas González, C.R.; Fernández Ruiz, M. Influence of flanges on the shear-carrying capacity of reinforced concrete beams without web reinforcement. Struct. Concr. 2017, 18, 720–732. [Google Scholar] [CrossRef] [Scilit]
  48. Autrup, F.; Jørgensen, H.B.; Hoang, L.C. Dowel action of the tensile reinforcement in RC beams without shear reinforcement: Novel experimental investigation and mechanical modelling. Eng. Struct. 2023, 279, 115471. [Google Scholar] [CrossRef] [Scilit]
  49. Gomes, T.A.; de Resende, T.L.; Cardoso, D.C.T. Shear-transfer mechanisms in reinforced concrete beams with GFRP bars and basalt fibers. Eng. Struct. 2023, 289, 116299. [Google Scholar] [CrossRef] [Scilit]
  50. Cavagnis, F.; Fernández Ruiz, M.; Muttoni, A. A mechanical model for failures in shear of members without transverse reinforcement based on development of a critical shear crack. Eng. Struct. 2018, 157, 300–315. [Google Scholar] [CrossRef] [Scilit]
  51. Costa, G.; Campos, C.M.O.; Martha, L.F.; Cardoso, D.C.T. Novel Multiaction Model for Shear Strength Prediction of Reinforced Concrete Beams: Development and Application to Elements with FRP Bars and FRC. J. Compos. Constr. 2025, 29, 04024092. [Google Scholar] [CrossRef] [Scilit]
  52. Karim, M.R.; Islam, K.; Billah, A.H.M.M.; Alam, M.S. Shear Strength Prediction of Slender Concrete Beams Reinforced with FRP Rebar Using Data-Driven Machine Learning Algorithms. J. Compos. Constr. 2023, 27, 04023003. [Google Scholar] [CrossRef] [Scilit]
  53. Marani, A.; Nehdi, M.L. Predicting shear strength of FRP-reinforced concrete beams using novel synthetic data driven deep learning. Eng. Struct. 2022, 257, 114083. [Google Scholar] [CrossRef] [Scilit]
  54. Xiang, P.; Lin, Y.; Huang, W.; Ding, F.; Ye, B.; Deng, Z. Investigation on Shear Capacity of Joints between Steel Reinforced Concrete Special-Shaped Column and Reinforced Concrete Beam. Front. Mater. 2020, 7, 588296. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.