The rapid regional vulnerability assessment of reinforced concrete (RC) building inventory is often undertaken using sample structures selected based on limited criteria such as topology, construction date, and material type. In more detailed vulnerability assessment studies, the lateral force-resisting system, dimensions, and reinforcement of structural members are considered. However, the internal orientation of vertical structural members may significantly impact the accuracy of the vulnerability assessment of existing buildings and thus deserves further consideration. The seismic performance of twelve existing buildings with different RC configurations and column orientations is thus investigated in this study, aiming to assess their impact on the anticipated seismic risk. A refined fiber-based modeling approach and two sets of natural earthquake records, representing the seismicity of the study area, are adopted to capture seismic demands effectively. The relative seismic performance of different building configurations and column orientations is assessed using fragility functions derived from a large number of multi-record incremental dynamic analyses, considering realistic performance limit states. An uncertainty-weighted performance indicator was employed to enable effective comparisons of seismic performance among the benchmark buildings. It is concluded that column orientation significantly influences the dynamic characteristics and seismic performance of RC buildings, with differences in the predominant vibration periods of up to 100% and in the performance indicator of up to 54% and 88% for the short- and long-period seismic scenarios, respectively. The study illustrates the importance of considering various structural configurations, column layouts, and seismic scenarios to arrive at reliable seismic vulnerability estimates at the urban scale.
1. Introduction
The lessons learned from the magnitude Mw 7.8 and 7.5 Kahramanmaraş earthquake sequence that devastated Türkiye and Syria on February 6, 2023, reminded the engineering community to strive towards reliable seismic loss assessment and risk mitigation policies for the built environment in earthquake-prone regions [1,2]. The observed damage and collapse of structures in the aftermath of this earthquake included a large number of substandard reinforced concrete (RC) buildings [3,4]. The inadequate seismic performance of substandard buildings is due to the fact that the structural system cannot meet the seismic performance objectives intended by modern seismic design standards. The implications of neglecting the seismic risk of substandard structures are catastrophic, particularly for critical structures such as educational buildings that could be used as post-earthquake shelters [1,5,6,7]. The high number of students in school buildings can also increase the death toll during an earthquake. Therefore, a reliable seismic performance assessment of substandard educational buildings with different structural systems and configurations under the anticipated seismic scenarios is essential to help decision-makers deploy effective retrofit schemes to mitigate unacceptable seismic risk (e.g., [7,8,9]). Substandard RC buildings exhibit limited lateral resistance and are vulnerable to several failure modes under earthquake loads. The common deficiencies in this class of buildings due to inadequate seismic design are related to overall stiffness, strength, and ductility [10]. These deficiencies are mainly related to the lateral force-resisting system (LFRS), and in many cases, to its vertical structural members [11]. Therefore, the structure’s lateral performance should be verified for inadequate stiffness, strength, or ductility.
Procedures and standards are available for the seismic evaluation and retrofit of existing buildings and bridges [12,13]. Previous studies also focused on the seismic performance assessment and retrofit of substandard RC structures [14,15,16,17]. However, there is a lack of vulnerability assessment studies in several parts of the world, particularly related to substandard buildings with different LFRS configurations and vertical structural member orientations. The most realistic seismic assessment procedures recommended by seismic evaluation guidelines and adopted in previous studies mainly focus on the inelastic response of the structure under anticipated earthquake scenarios. Inelastic time-history analysis using a wide range of input ground motions representing the study region is recommended to capture the inelastic seismic response realistically [10]. To evaluate the inelastic seismic performance of the structure effectively, acceptable performance levels should be defined. Performance-based standards and guidelines have a range of performance levels that can be used to allow immediate occupancy (IO) after an earthquake or just to meet a collapse prevention (CP) performance level. However, substandard buildings evaluated against a certain performance level, such as CP, are expected to have more deficiencies than a similar code-conforming structure [11]. Therefore, performance limit state (PLS) criteria for substandard buildings with different configurations should be based on selected structures that represent the exposed inventory, since failure modes are influenced by several factors, including local design provisions and construction trends.
Fragility functions represent the probability of attaining or exceeding specified damage states as a function of ground motion intensity (GMI); hence, they play a crucial role in seismic loss estimations. Consequently, the approaches to deriving vulnerability relations have been the subject of focused research. Analytical approaches are extensively used for deriving fragility functions as they rely on dynamic response simulations to evaluate structural damage rather than observations or judgments. Several techniques for developing vulnerability functions from simulated structural damage were used in previous studies, with different modeling approaches, analysis methods, and performance levels [18]. Effective analytical techniques usually adopt detailed numerical models of the exposed structures, multi-record incremental dynamic analysis (MRIDA) procedure, and a wide range of earthquake records to represent the ground motion uncertainties and seismo-tectonic characteristics of the study region. Thus, the present study effectively uses different components previously discussed and recommended in vulnerability studies in the methodology adopted to assess the seismic performance of substandard buildings probabilistically. It is noteworthy that the MRIDA procedure involves incrementally scaling multiple ground motion records, representing two seismic scenarios, to assess structural response at different intensity levels, from elastic behavior until reaching structural collapse. Although this procedure requires substantial computational effort and requires the cautious selection and scaling of ground motion records, it enables a comprehensive assessment of nonlinear structural responses across different performance levels and effectively accounts for variations in ground motion characteristics and their influence on seismic demand [19]. This approach has also been adopted in several previous seismic performance and vulnerability assessment studies [20,21,22]. Recent studies have also explored data-driven approaches for predicting seismic damage in RC structures and highlighted the importance of integrating structural performance assessment with reliability and risk assessment to support rehabilitation and retrofitting decisions [23,24].
Regional seismic vulnerability assessments of RC buildings commonly rely on representative structures selected based on general characteristics, such as building topology, construction period, and structural system. The internal orientation of vertical structural members within the building plan is often overlooked, despite its potential influence on seismic response. Variations in column orientation may affect lateral stiffness and strength, consequently introducing uncertainties in seismic vulnerability assessment. This study addresses this issue by assessing the seismic performance of substandard school buildings with different configurations and column orientations to estimate their potential impact on seismic losses in a region of moderate seismicity selected as the case study. The study achieves its objective using detailed fiber-based (FB) numerical models of twelve benchmark structures. Fragility functions are derived using MRIDAs and a wide range of input ground motions representing two seismic scenarios pertaining to the selected study area to provide insights into the relative damage of structures with different configurations and column orientations at different performance levels.
2. Case Study Structures
This study focuses on the seismic performance of substandard school buildings with different configurations and vertical structural member orientations constructed before an earthquake that caused extensive damage to old structures in Egypt in 1992 [25,26]. After this date, major revisions took place to the seismic design provisions in Egypt [27,28]. Therefore, the Faiyum district, Egypt, was selected as the study area in the present study. This area is 130 km southwest of Cairo. The building database for this study was collected using several site visits to help collect the information needed for this study, including structural and soil characteristics. Figure 1 depicts the distribution of the surveyed buildings in the study area. The survey statistics indicate that most school buildings are 3–5-story RC moment-resisting frame (MRF) buildings constructed on silty clay soil. In addition, one-third of the buildings were built before 1992 and thus considered substandard structures. The surveyed structures also indicated that the school inventory includes the four building configurations shown in Figure 2. A uniform building height of three stories was adopted for all configurations, consistent with the range identified in the field survey, to ensure a constant number of stories across all building configurations. Finally, the three column orientations considered for each of the four benchmark school buildings are illustrated in Figure 3 for configuration M1 as a representative example.
Figure 1.
Distribution of school buildings in the selected study area.
Figure 2.
Configuration and dimensions of benchmark structures to represent surveyed school buildings in the study area.
Figure 3.
Investigated column orientations: (a) longitudinal alignment, (b) transverse alignment, and (c) mixed alignment (illustrated for configuration M1 and adopted for the four benchmark structures).
The selection of a representative structural configuration from the surveyed buildings is necessary given the substantial computational effort required by the detailed modeling and analysis procedures employed in this study to assess the seismic vulnerability of substandard buildings using realistic modeling and analysis techniques, as explained hereafter. Twelve benchmark buildings were selected according to their configurations and column arrangement. The twelve case studies result from different combinations of the four MRF buildings and the column layouts shown in Figure 2 and Figure 3, respectively. The layout of the buildings consists of several segments separated by expansion joints. Each selected building has a total height of 11.4 m, comprising a 5.0 m ground story and upper stories of 3.2 m each, as illustrated in Figure 2. The main LFRSs are RC MRFs, with the buildings founded on silty clay soil. The floor system is a solid slab. Live loads and loading from floor finishes are 5.0 kN/m2 and 1.5 kN/m2, respectively. The concrete cube strength and steel yield strength are 25 MPa and 240 MPa, respectively. A sample of reinforcement details of different structural members in building M4 with column layout ‘a’ (M4-a) is depicted in Figure 4. These substandard school buildings were constructed before 1992 without seismic provisions; hence, the MRFs in the longitudinal and transverse directions do not satisfy the capacity design principles recommended by modern provisions.
Figure 4.
Sample of the reinforcing steel for the benchmark structure M4 with column layout ‘a’ (M4-a); ∅ refers to ‘rebar diameter’.
3. Structural Idealization
Detailed FB numerical models were developed for the benchmark buildings to capture the inelastic seismic response of the selected substandard RC structures when subjected to strong ground motions. A verified inelastic analysis platform, which effectively predicts the large displacement behavior of space frames under static and dynamic loading, was employed in the present study [29]. The adopted inelastic analysis platform was verified and used in several large research projects covering substandard RC buildings and modern high-rise structures, among others [11,17,18]. Each structural member is modeled using four cubic elasto-plastic beam-column elements with distributed plasticity, using two Gauss integration points per element. The cubic elasto-plastic elements are distributed along each member in ratios of 15%, 35%, 35%, and 15% to provide fine discretization near the member ends. The element cross-sections are divided into several fibers, and the cross-section response is assembled from the responses of the individual fibers. The FB models also consider material and geometrical nonlinearities, including second-order P–Δ effects arising from the interaction between vertical gravity loads and lateral displacements [29]. The floor slabs are modeled using inelastic frame elements with equivalent sections defined considering the beams and the effective slab width, thickness, and reinforcement. This modeling approach effectively captures out-of-plane deformations and the development of plastic hinges without imposing rigid diaphragm constraints, thereby providing a more realistic representation of the benchmark buildings with different column orientations. The concrete cyclic behavior is represented using the Mander-based uniaxial nonlinear constant-confinement concrete model implemented in the adopted software [29,30]. The confinement factors for column and beam sections are calculated based on the actual transverse reinforcement detailing to account for the limited confinement of such substandard buildings. Confined concrete properties are assigned to the core regions of the RC sections, while unconfined concrete is considered for the cover regions. Concrete tensile strength is neglected to improve numerical stability, as previous sensitivity analyses based on shake-table tests indicated that this assumption has a limited influence on the global nonlinear structural response [31]. An elasto-plastic model with a kinematic hardening rule for the yield surface is selected to represent the steel reinforcement [29]. The adopted cyclic concrete model incorporates stiffness and strength degradation at the material level within the fiber sections [29]. Hysteretic energy dissipation is inherently accounted for through the nonlinear cyclic response of the structural elements [29].
Actual strength is used to model the material response rather than nominal strengths. Based on the expected critical response, inelastic pushover analysis (POA) is employed to evaluate the nonlinear lateral response and monitor the progressive development of structural damage [32,33], while MRIDA is used to assess the seismic response under incrementally scaled ground motions. Both analyses are conducted in the X (longitudinal) direction. In the dynamic analysis, inertia effects are accounted for by applying lumped mass elements in the same manner as for gravity loads. The columns of the five benchmark structures are considered fixed at the foundation level. In addition to permanent loads, the benchmark structures are subjected to transient loads, consisting of accelerations that vary in the time domain. The numerically dissipative Hilber–Hughes–Taylor integration algorithm, for which accuracy is not affected by the time step length, was adopted in the present study to solve the equations of motion [29].
4. Input Ground Motion Setups and Impact of Structural Members’ Orientations on Dynamic Characteristics
Two groups of natural earthquake records were selected for the vulnerability assessment of the benchmark structures, as shown in Table 1 and Figure 5. Twenty natural records were selected to fit the design code response spectra for the case study region for a 10% probability of exceedance in 50 years [28,34]. The selected ground motions represent two seismic scenarios, namely (i) short-period ground-motion records (Scenario S) and (ii) long-period ground-motion records (Scenario L). The accelerograms were selected from the Pacific Earthquake Engineering Research Center database [35]. The elastic response spectra of the selected natural records and the design response spectra for 10% probability of exceedance are shown in Figure 5. It can be seen that the mean spectra effectively matched the two seismic scenarios recommended by the design code [28]. As per the recommendations of modern seismic codes and previous studies, the mean spectra were not less than the design response spectrum for periods ranging from 0.2 to 2.0 times the average fundamental period of the benchmark structures, as presented later in this study [36]. As shown in Table 1, ten records representing Scenario S were selected with moment magnitudes (Mw) ranging from 5.38 to 6.69, high peak ground acceleration-to-peak ground velocity (a/v) ratios (>1.2 g/m/s), and peak ground acceleration (PGA) values from 0.17 to 0.33 g. For the ten records representing Scenario L, input ground motions were selected with Mw ranges from 6.30 to 7.62, low and intermediate a/v ratios (<1.2 g/m/s), and PGA values between 0.13 and 0.27 g.
Table 1.
Selected earthquake records to represent short-period and long-period ground-motion scenarios (Scenarios S and L).
Figure 5.
Response spectra of the design code and selected ground-motion records, along with their mean spectra and the predominant period range of the benchmark buildings: (a) Scenario S and (b) Scenario L.
Figure 5 depicts the predominant period range of the benchmark buildings. Figure 6 presents the periods of vibration of the first three modes of the reference buildings. Figure 7 also pictorially explains the impact of changing the column orientation on the dynamic characteristics, spectral acceleration, and seismic response of building M1 as a representative example. It is confirmed from Figure 5, Figure 6 and Figure 7 that changing the column orientations significantly shifts the predominant period of vibration of the benchmark structures by up to 100%. This variation is primarily attributed to changes in lateral stiffness. The longest periods occur when the shorter cross-sectional dimensions of the columns are aligned with the direction of analysis in configuration (b), resulting in lower lateral stiffness. Conversely, aligning the longer cross-sectional dimensions with the analysis direction in configuration (a) increases the second moment of area and lateral stiffness, leading to the shortest periods, while configuration (c), featuring mixed column orientations, exhibits intermediate periods.
Figure 6.
Periods of vibration (Sec.) of the twelve benchmark buildings (M1 to M4) with the column layouts ‘a‘, ‘b‘, and ‘c‘.
Figure 7.
Impact of column orientation on the dynamic characteristics, spectral acceleration, and seismic response of building M1.
Moreover, Figure 8 presents the distributions of spectral accelerations derived from the response spectra of ground motion records for each seismic scenario across the twelve benchmark structures. The results demonstrate that variations in the fundamental periods resulting from changes in column orientation lead to differences in the corresponding spectral accelerations, with the magnitude of these differences depending on the characteristics of the ground motion scenarios. These findings highlight the importance of further investigating the influence of column orientation on the seismic response and fragility of the benchmark structures under different seismic scenarios.
Figure 8.
Distributions of spectral accelerations derived from the response spectra of ground motion records for each seismic scenario across the twelve benchmark structures, highlighting the significant influence of column orientation on the anticipated seismic response.
Seismic vulnerability assessment involves various sources of uncertainty that may significantly influence the predicted structural response and associated fragility estimates. Monte Carlo simulation can be employed to account for multiple sources of uncertainty; however, computational effort increases rapidly when increasing the range of benchmark structures. Previous studies concluded that the most important source of uncertainty in vulnerability assessment is related to the input ground motions, particularly when focusing on a specific class of structures [37]. Therefore, this study focused on uncertainty related to input ground motions representing different seismic scenarios. Meanwhile, uncertainties associated with material properties and analytical modeling were considered deterministic, considering the detailed FB numerical models and the analysis procedure adopted in the present study.
The vulnerability assessment of the selected benchmark structures was carried out using MRIDA. The developed FB models of the benchmark structures were assessed under the effect of the two selected input ground motion sets (Table 1 and Figure 5). Each scenario was scaled to different PGA levels to investigate the seismic performance of reference structures from elastic behavior until reaching structural collapse. The direct PGA scaling method was selected because it links seismic forces directly to input accelerations while preserving the records’ essential spectral features. This straightforward approach provides a common intensity measure suitable for comparing the seismic performance of different building configurations and column orientations without requiring structure-specific scaling intensity measures. Although the PGA scaling method does not explicitly account for the frequency content of ground motions relative to the vibration periods of the investigated structures, which may lead to variations in the predicted seismic demands among earthquake records scaled to the same PGA, the present study employs a large number of earthquake records representing two seismic scenarios to investigate how variations in ground-motion frequency content influence the seismic response of the benchmark structures.
To improve the accuracy of the vulnerability curves and attain all limit states, a scaling increment of 0.10 g was selected for the Scenario S ground motions. Fifteen analyses were conducted for each building-input ground motion, starting at a PGA of 0.10 g and ending at 1.50 g. This range encompasses the design earthquake intensity (DEI) of 0.15 g specified for the study area [28]. Figure 5 shows that the two ground motion sets selected in the present study have different spectral amplification at various periods. Therefore, the scaling approach above-mentioned is inappropriate for the Scenario L earthquakes since a lower level of PGAs is needed to reach the collapse limit states compared with the PGAs used with the Scenario S ground motions. A scaling factor of 0.05 g was thus selected for the Scenario L input ground motions.
5. Selection of Performance Limit States Using Different Analysis Procedures
Three PLSs were adopted in the present study: IO, life safety (LS), and CP [13]. The interstory drift ratio (IDR) is the main global damage measure (DM). The IDRs corresponding to the IO, LS, and CP PLSs adopted by seismic design guidelines for code-conforming concrete MRFs are 1%, 2%, and 4%, respectively [38]. Because these IDR limits are non-conservative for substandard buildings with limited strength and ductility, previous studies adopted the reduced IDR values of 0.5%, 1%, and 2%, respectively, for low- and medium-rise substandard buildings based on the column rotations proposed in ASCE [39]. Based on shake-table testing and dynamic response simulation, other studies recommended different IDR limits for pre-seismic code MRFs associated with IO, LS, and CP PLSs of 0.39%, 1.48%, and 2.96%, respectively [11,16].
In the present study, POA and MRIDA were adopted to assess both local and global system response, in addition to predicting the PLSs of the benchmark structures. The yielding of tensile steel bars was monitored throughout the POA process. Plastic hinge (PH) formation is considered when the strain of the main reinforcing steel exceeds the yield strain. For MRIDA, the ultimate confined concrete strain is also monitored for possible local failure from concrete crushing. The IDRs corresponding to the local and global damage indices obtained from POA and MRIDA serve as part of the selection approach used to define the PLSs for the investigated buildings. The estimated PLSs are compared with those proposed in the design guidelines and previous studies. The IO PLS is estimated locally from the first indication of PH formation, while it is estimated globally from MRIDA curves based on the point of initial deviation from elastic response. The CP threshold is defined as the point at which the stiffness degrades to 20% of its initial elastic value. The LS PLS, which falls between the IO and CP, represents ‘significant damage’ sustained by the structure while accounting for a reasonable margin of safety against collapse. This margin is 50% of the CP PLS [13,17,38].
A sample of the capacity curves and IDR distributions obtained from POA is depicted in Figure 9a. The sequence of PH formation in columns and the corresponding maximum IDRs are monitored, and IDRs at the first indication of yielding in columns are recorded for the twelve benchmark structures, as depicted in Figure 9b. Although the hinging mechanism at the ground story is observed at high IDRs, it is shown in Figure 9b that this is an expected failure mode in substandard educational structures. However, this failure criterion is observed at a relatively higher IDR than those suggested in previous studies for substandard buildings (e.g., 4.0% for building M1-a).
Figure 9.
Sample results from inelastic pushover analysis (POA) and multi-record incremental dynamic analysis (MRIDA) for the M1-a benchmark building: (a) capacity curve and interstory drift ratio (IDR) distribution, (b) sequence of column plastic hinge formation under POA and IDR at the first indication of column yielding, and (c) MRIDA curves using Scenario L earthquake records and the predicted collapse points for M1-a.
Regression analyses were conducted for the results obtained from MRIDAs under twenty input ground motions to predict the IO and CP PLSs. Figure 9c shows the MRIDA curves using Scenario L earthquake records for the M1-a building as a representative example. Table 2 summarizes the results of the regression analyses at the 16th and 50th percentiles for the twelve benchmark buildings. The variability in performance limits under different ground motions is shown in the analysis results presented in Table 2. Figure 10 depicts the distribution of the IO and CP limit states obtained from the twelve benchmark structures and the two earthquake scenarios investigated in the present study. These distributions suggest that a lognormal distribution is appropriate for fitting the MRIDA results. Accordingly, Figure 11 depicts the lognormal distributions of the IO and CP PLSs obtained from the POA and MRIDA results for both earthquake scenarios (i.e., Scenarios S and L). The results indicate that the IO distributions are generally concentrated, whereas the CP distributions exhibit greater variability, reflecting differences in the structural responses under the investigated seismic scenarios.
Table 2.
Performance limit states (PLSs) of benchmark structures obtained from the regression analysis of the MRIDA results.
Figure 10.
Distribution of immediate occupancy (IO) (a) and collapse prevention (CP) (b) PLSs of twelve benchmark structures and twenty input ground motions representing seismic Scenarios S and L.
Figure 11.
Lognormal distributions of the IO (a) and CP (b) PLSs of twelve benchmark structures and twenty input ground motions representing seismic Scenarios S and L.
The PLS results obtained from the POA, MRIDA, and those recommended by previous studies and design guidelines are summarized in Table 3 [11,16,38,39]. The PLSs derived from the POA and MRIDA are determined using the 16th percentile of the IDRs obtained for the twelve buildings, assuming a lognormal distribution. The POA and MRIDA results show that the most conservative IDR at the IO PLS is 0.33%. The adopted IDR at the CP PLS is 2.96%, based on the most conservative value from the present study’s MRIDA results and those recommended in previous studies. The IO and CP PLSs of the benchmark structures are consistent with those recommended in recent studies based on shake-table testing and simulation of substandard RC MRFs [11,16]. Finally, the LS PLS is 50% of the CP PLS [13,38]. Compared with the IDR values of 1%, 2%, and 4% associated with the IO, LS, and CP performance levels in ASCE 41, the selected thresholds are slightly conservative, particularly for the LS and CP PLSs [38]. The observed differences between the present study and ASCE 41 IDR values, especially for the IO PLS, are attributed to the reinforcing steel used in the case study substandard buildings (i.e., fy = 240 MPa), which results in early yielding and reduced strength and ductility compared with well-designed structures. This discussion shows that conservative PLSs were adopted in the present study based on regression analyses of the inelastic simulation results obtained from POA and MRIDA, in addition to the values adopted in previous studies. The methodology adopted lends weight to the performance criteria selected in the present study.
Table 3.
Comparisons of the PLSs obtained from POA and MRIDA with those recommended by previous studies.
6. Fragility Assessment of Buildings with Different Configurations and Structural Members’ Orientations
Fragility functions were developed in the present study for the twelve benchmark structures using MRIDA and two sets of input ground motions to represent Scenarios S and L. The fragility function represents a relationship between the GMI measure and the probability of reaching PLS. The fragility functions, which follow a lognormal distribution, are derived considering the drift capacity and demand and the uncertainties associated with demand, drift capacity, and the imperfection of numerical modeling [18,40]. As discussed above, the most important source of uncertainty is related to seismic demand and is accounted for using the selected range of input ground motions. The uncertainties associated with material properties and analytical modeling are considered deterministic parameters, with values of 0.3 and 0.2, respectively, based on the recommendations of previous studies [21,40].
The input ground motions selected in the present study represent two specific seismic scenarios. Hence, the GMI measure used for developing the fragility curves is the PGA. This scaling method was adopted in the present work since it is consistent with the approach employed by design codes and in several previous studies [11,17,18]. Figure 12 shows the relationship between DM and GMI for the M1 to M4 benchmark structures with column orientation ‘a’ based on MRIDAs performed using Scenario L earthquake records. Several GMI-IDR points obtained from MRIDAs are plotted for each benchmark building. The mean of the DM as a function of GMI is determined by the regression analysis for each of the two seismic scenarios. The statistical distributions obtained from MRIDAs are used to calculate the limit state exceedance probabilities (LSEPs) at different GMI levels used for developing fragility relationships [40].
Figure 12.
Relationship between the damage measure and ground motion intensity for the M1 to M4 benchmark structures with column orientation ‘a’, using MRIDAs along with the IO, LS, and CP PLSs shown as dotted lines (sample results using Scenario L records).
Figure 13 compares the fragility relationships derived using Scenarios S and L for the substandard building configurations M1 to M4 with the structural members’ orientations ‘a’ to ‘c’. The fragilities are derived for three PLSs: IO, LS, and CP. The higher impact of Scenario L on the seismic response of the benchmark structures is shown in Figure 13, particularly for column layouts ‘a’ and ‘c’. The slopes are steeper, and the LSEP is much higher under the effect of the Scenario L input ground motions than under the Scenario S earthquake records. The response of benchmark structures with column layout ‘b’ does not follow the same trend for some structures. This is due to the lower lateral stiffness and strength of buildings with this structural member’s orientation, which significantly elongate the periods of vibration and change the spectral amplification of these benchmark buildings compared with structures with column layouts ‘a’ and ‘c’.
Figure 13.
Developed fragility relations of twelve benchmark structures with different configurations, M1 to M4, and structural member orientations, (a–c), using MRIDAs and twenty earthquake records representing two earthquake scenarios, Scenarios S and L.
Given the fragility estimates, ground motion intensities represented by PGA at three different LSEPs, namely 16%, 50%, and 84% for earthquake Scenarios S and L, were calculated and are depicted in Figure 14. It is shown that the GMIs required to reach the three LSEPs of 16%, 50%, and 84% for the twelve benchmark buildings are much higher under earthquake Scenario S than under Scenario L. The results presented in Figure 14 reflect the greater severity of earthquake Scenario L and its higher impact on the benchmark buildings due to higher spectral amplifications of the Scenario L earthquake records than their short-period counterparts, as confirmed by Figure 5, Figure 7 and Figure 8. Figure 15 compares the median GMIs corresponding to 16%, 50%, and 84% LSEPs across the three damage PLSs (IO, LS, and CP) for earthquake Scenarios S and L. Figure 14 and Figure 15 show that for earthquake Scenario S, the median GMIs at 50% LSEP are 0.08 g, 0.39 g, and 0.80 g for the IO, LS, and CP PLSs. The results highlight the vulnerability and limited safety margins of the gravity-load-designed benchmark structures under Scenario L. For the LS PLS, the median GMIs corresponding to 16% and 50% LSEPs are 0.11 g and 0.18 g, respectively. Considering the DEI of 0.15 g, which falls between these two values, the probability of exceeding the LS PLS is between 16% and 50%, indicating limited safety margins. On the other hand, under Scenario S, the corresponding GMIs are 0.25 g and 0.39 g, respectively, both exceeding the DEI of 0.15 g. Consequently, the probability of exceeding the LS PLS at the DEI is less than 16%, indicating a higher safety margin compared with Scenario L.
Figure 14.
Ground motion intensity (GMI) corresponding to limit state exceedance probabilities (LSEPs) of 16% (left), 50% (middle), and 84% (right) for earthquake Scenario S (top) and Scenario L (bottom).
Figure 15.
Impact of earthquake scenario on median ground motion intensities (GMIs) at 16%, 50%, and 84% limit state exceedance probabilities (LSEPs).
Moreover, Figure 14 confirms the significant impact of the structural configuration and vertical members’ orientations on the seismic performance and LSEPs of the substandard benchmark buildings for the IO, LS and CP PLSs. The GMIs corresponding to 16%, 50% and 84% LSEPs vary for different building configurations and within each group of benchmark structures with column layouts ‘a’ to ‘c’. This is due to the impact of the LFRS and structural members’ orientation on the lateral stiffness and strength of the building, which in turn changes the elastic and inelastic periods of vibration and corresponding spectral amplification. The results presented in Figure 13, Figure 14 and Figure 15 confirm that the rapid vulnerability assessment of RC buildings merely based on their topologies and construction materials may result in gross errors in estimating seismic losses, particularly under the effects of different seismic scenarios.
7. Quantifying the Seismic Performance
Since the LSEPs estimated using the fragility functions vary across PLSs and under the two seismic scenarios, and as the uncertainty associated with the fragilities increases when moving from the IO to the CP PLSs, a reliable indicator is needed to translate the fragility functions into a seismic performance index. The following performance indicator (PI) was adopted in this study based on the median GMI (Mi) at PLS (i) and a weighting factor for different PLSs calculated using their standard deviation (SDi) as follows:
where n is the total number of limit states considered, and (SDi) is the standard deviation used as a weighting factor for different limit states to account for the associated uncertainties. The proposed approach assigns more weight to PLSs with lower dispersion in their fragility distributions, reflecting greater confidence in their estimated seismic capacities, while reducing the weight of PLSs exhibiting greater dispersion and uncertainty. The PI value represents an uncertainty-weighted measure of seismic capacity, with higher values indicating better seismic performance, as the structure can sustain greater ground motion intensities before reaching the considered PLSs. Figure 16 presents the PI values obtained for the investigated structural buildings under both earthquake Scenarios S and L, allowing for a comparative assessment of their seismic performance. As shown in Figure 16, PI values are consistently higher under earthquake Scenario S than under Scenario L, indicating better seismic performance under Scenario S ground motions. Noticeable variations were observed among the investigated school building configurations and vertical structural members’ orientations under each seismic scenario. These variations highlight the significant influence of the internal orientation of vertical structural members on seismic performance, even for buildings with identical structural typologies and construction materials. For building configurations M1 to M4, the internal orientation of vertical structural members resulted in differences in PI ranging from 22% to 88% for seismic Scenario L and 24% to 54% for Scenario S (Figure 16). The results of the present study confirm that neglecting the internal orientation of vertical structural members leads to inaccurate predictions of seismic performance, and consequently, substantial errors in regional seismic loss estimation.
Figure 16.
Comparison of the performance indicator (PI) values of the investigated structural models under earthquake Scenarios S and L.
8. Conclusions
The seismic performance of existing buildings with different reinforced concrete configurations and column orientations constructed in a medium seismicity region was investigated in this study. A refined fiber-based modeling approach was adopted, and two sets of earthquake records were selected to represent the seismic scenarios that the study region is exposed to. Two types of analyses, inelastic pushover analysis (POA) and multi-record incremental dynamic analysis (MRIDA), were conducted to assess both local and global system responses, in addition to predicting the performance limit states (PLSs) of the benchmark structures. The relative seismic performance of different building configurations was described using fragility functions and an uncertainty-weighted performance indicator (PI) to compare the seismic performance of the investigated buildings under the two earthquake scenarios. Based on the results obtained, the following conclusions were drawn:
- •
- The internal orientation of vertical structural members had a significant influence on the dynamic characteristics of the benchmark buildings, shifting their predominant periods of vibration by up to 100%, resulting in spectral acceleration amplifications.
- •
- The seismic scenario significantly influenced the fragility curves and safety margins of the investigated buildings. The long-period ground-motion scenario (Scenario L) generally resulted in higher probabilities of exceeding the investigated PLSs than the short-period ground-motion scenario (Scenario S). At the design earthquake intensity of 0.15 g, the probability of exceeding the LS PLS ranged between 16% and 50% under Scenario L compared with less than 16% under Scenario S.
- •
- The uncertainty-weighted PI showed lower vulnerability under Scenario S than under Scenario L. The variations in PI values among the benchmark buildings also confirmed that column internal orientations resulted in differences in the PI ranging from 22% to 88% for seismic Scenario L and 24% to 54% for Scenario S for the M1 to M4 buildings, despite exhibiting identical structural typologies and construction materials.
- •
- The findings of the present study demonstrated that rapid regional vulnerability assessments based merely on building topologies and construction materials could result in substantial errors in seismic loss estimation. The influence of structural configurations, column orientations, and earthquake scenarios on the seismic performance of the case study structures highlights the importance of considering these parameters to improve the reliability of urban-scale seismic vulnerability assessments. From a practical perspective, engineers can incorporate column orientation as an additional parameter in regional seismic vulnerability assessments by identifying the orientations of vertical structural members using available structural drawings or field surveys. Representative buildings can then be selected based on their structural configurations and column orientations to develop fragility functions under realistic seismic scenarios, thereby improving the reliability of regional seismic vulnerability and loss estimates.
Finally, while this study provides insights into the influence of different column orientations on the seismic performance of existing substandard school buildings, future studies could investigate a wider range of building configurations and three-dimensional structural response under bidirectional seismic excitation. Furthermore, more refined performance limit states that account for the shear capacity of structural members, as well as the influence of masonry infill walls, could be adopted to provide a more realistic representation of the seismic behavior of such substandard buildings.
Author Contributions
Conceptualization, S.E. and A.M.; methodology, S.E. and A.M.; software, S.E. and A.M.; validation, M.F.A., S.E. and A.M.; formal analysis, S.E. and A.M.; investigation, M.F.A., S.E. and A.M.; resources, S.E. and A.M.; data curation, M.F.A., S.E. and A.M.; writing—original draft preparation, M.F.A., S.E. and A.M.; writing—review and editing, M.F.A., S.E. and A.M.; visualization, M.F.A., S.E. and A.M.; supervision, A.M.; project administration, A.M.; funding acquisition, A.M. All authors have read and agreed to the published version of the manuscript.
Funding
This research work was financially supported by the United Arab Emirates University under research grant No. 12N165.
Data Availability Statement
The data used to support the findings of this study are available upon request.
Acknowledgments
This research work was financially supported by the United Arab Emirates University under research grant No. 12N165. The support provided by United Arab Emirates University is gratefully acknowledged.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
| a/v | Peak Ground Acceleration-to-Peak Ground Velocity |
| CP | Collapse Prevention |
| DEI | Design Earthquake Intensity |
| DM | Damage Measure |
| FB | Fiber-Based |
| GMI | Ground Motion Intensity |
| IDR | Interstory Drift Ratio |
| IO | Immediate Occupancy |
| LFRS | Lateral Force-Resisting System |
| LS | Life Safety |
| LSEP | Limit State Exceedance Probability |
| MRIDA | Multi-Record Incremental Dynamic Analysis |
| MRF | Moment-Resisting Frame |
| Mw | Moment Magnitude |
| PGA | Peak Ground Acceleration |
| PH | Plastic Hinge |
| PI | Performance Indicator |
| PLS | Performance Limit State |
| POA | Pushover Analysis |
| RC | Reinforced Concrete |
| Scenario L | Long-Period Ground-Motion Scenario |
| Scenario S | Short-Period Ground-Motion Scenario |
References
- Altıok, T.Y.; Şevik, M.; Demir, A. Seismic performance of retrofitted and non-retrofitted RC school buildings after the February 6th, 2023, Kahramanmaraş earthquakes. Bull. Earthq. Eng. 2025, 23, 1017–1052. [Google Scholar] [CrossRef] [Scilit]
- Işık, E.; Karaçam, R.; Harirchian, E.; Hadzima-Nyarko, M. Comparative Analysis of Post-Earthquake Damage and Structural Irregularities in RC Buildings: Field Evidence from the 2023 Kahramanmaraş (Türkiye) Earthquakes. Buildings 2026, 16, 1140. [Google Scholar] [CrossRef] [Scilit]
- Bayraktar, A.; Bayraktar, S.; Núñez, T.R.; Brzev, S.; Ventura, C.E.; Yang, T.Y.; Akköse, M.; Hökelekli, E.; Taş, Y. Correlation of seismic demand and performance for severely damaged low-rise buildings during the February 2023 Kahramanmaraş, Türkiye, earthquake sequence. Soil Dyn. Earthq. Eng. 2026, 203, 109999. [Google Scholar] [CrossRef] [Scilit]
- Yenidogan, C. Seismic performance of SI and conventional healthcare facilities during the February 6, 2023, earthquakes: Validation of SI system response per the TSDC-2018. Eng. Struct. 2026, 357, 122167. [Google Scholar] [CrossRef] [Scilit]
- Elnashai, A.S.; Gencturk, B.; Kwon, O.-S.; Hashash, Y.M.; Kim, S.J.; Jeong, S.-H.; Dukes, J. The Maule (Chile) earthquake of February 27, 2010: Development of hazard, site specific ground motions and back-analysis of structures. Soil Dyn. Earthq. Eng. 2012, 42, 229–245. [Google Scholar] [CrossRef] [Scilit]
- Gautam, D.; Adhikari, R.; Rupakhety, R.; Koirala, P. An empirical method for seismic vulnerability assessment of Nepali school buildings. Bull. Earthq. Eng. 2020, 18, 5965–5982. [Google Scholar] [CrossRef] [Scilit]
- Tïmurlenk, P.; Uysal, Y.; Arslan, H.D.; Arslan, M.H. Multistage evaluation of strengthening strategies for achieving adequate seismic performance in reinforced concrete school buildings. Structures 2026, 84, 110977. [Google Scholar] [CrossRef] [Scilit]
- Elnashai, A.S.; Hajjar, J.F. Mid-America Earthquake (MAE) Center Program in Consequence-Based Risk Management. In Proceedings of the Eighth National Conference on Earthquake Engineering, 100th Anniversary Earthquake Conference: Managing Risk in Earthquake Country, San Francisco, CA, USA, 18–22 April 2006. [Google Scholar]
- Kim, S.; Choi, I.; Lee, K.; Shin, J. A rapid decision making process of retrofit scheme for seismically-vulnerable reinforced concrete school buildings using simple information. Structures 2025, 77, 109174. [Google Scholar] [CrossRef] [Scilit]
- Elnashai, A.S.; Di Sarno, L. Fundamentals of Earthquake Engineering: From Source to Fragility, 2nd ed.; John Wiley & Sons, Ltd.: West Sussex, UK, 2015; p. 347. [Google Scholar]
- Mwafy, A.M.; AlMorad, B. Verification of performance criteria using shake table testing for the vulnerability assessment of reinforced concrete buildings. Struct. Des. Tall Spec. Build. 2019, 28, e1601. [Google Scholar] [CrossRef] [Scilit]
- FHWA. Seismic Retrofitting Manual for Highway Structures: Part 1—Bridges; PFHWA-HRT-06-032; Research, Development, and Technology Turner-Fairbank Highway Research Center: McLean, VA, USA, 2006. [Google Scholar]
- ASCE/SEI-41; Seismic Evaluation and Retrofit of Existing Buildings, ASCE/SEI 41-23. American Society of Civil Engineers: Reston, VA, USA, 2023.
- Kahrizi, M.; TahamouliRoudsari, M. Seismic performance of school buildings in 2017 Ezgeleh Earthquake, Iran. Bull. N. Z. Soc. Earthq. Eng. 2020, 53, 70–82. [Google Scholar] [CrossRef] [Scilit]
- Ahmad, S.; Khan, R.A. Seismic Performance of a heritage school building. Procedia Eng. 2017, 173, 1763–1770. [Google Scholar] [CrossRef] [Scilit]
- Joseph, R.; Mwafy, A.; Alam, M.S. Shake-table testing and numerical simulation to select the FRCM retrofit solution for flexure/shear deficient RC frames. J. Build. Eng. 2023, 69, 106248. [Google Scholar] [CrossRef] [Scilit]
- Ghazal, H.; Mwafy, A. Seismic fragility assessment of an existing multi-span RC bridge equipped with risk mitigation systems. Buildings 2022, 12, 982. [Google Scholar] [CrossRef] [Scilit]
- Mwafy, A.; Hussain, N.; El-Sawy, K. Seismic performance and cost-effectiveness of high-rise buildings with increasing concrete strength. Struct. Des. Tall Spec. Build. 2015, 24, 257–279. [Google Scholar] [CrossRef] [Scilit]
- Vamvatsikos, D.; Cornell, C.A. Incremental dynamic analysis. Earthq. Eng. Struct. Dyn. 2002, 31, 491–514. [Google Scholar] [CrossRef] [Scilit]
- Mwafy, A.; Khalifa, S. Effect of vertical structural irregularity on seismic design of tall buildings. Struct. Des. Tall Spec. Build. 2017, 26, e1399. [Google Scholar] [CrossRef] [Scilit]
- Alwaeli, W.; Mwafy, A.M.; Pilakoutas, K.; Guadagnini, M. Rigorous versus less-demanding fragility relations for RC high-rise buildings. Bull. Earthq. Eng. 2020, 18, 5885–5918. [Google Scholar] [CrossRef] [Scilit]
- Ji, J.; Elnashai, A.S.; Kuchma, D.A. Seismic fragility relationships of reinforced concrete high-rise buildings. Struct. Des. Tall Spec. Build. 2009, 18, 259–277. [Google Scholar] [CrossRef] [Scilit]
- Lazaridis, P.C.; Kavvadias, I.E.; Demertzis, K.; Iliadis, L.; Vasiliadis, L.K. Interpretable machine learning for assessing the cumulative damage of a reinforced concrete frame induced by seismic sequences. Sustainability 2023, 15, 12768. [Google Scholar] [CrossRef] [Scilit]
- Zare, S.; Najafi, M. Artificial Intelligence for Structural Condition Assessment and Rehabilitation: Recent Advances and Future Directions. Buildings 2026, 16, 3401. [Google Scholar] [CrossRef] [Scilit]
- Badawi, H.S.; Mourad, S.A. Observations from the 12 October 1992 Dahshour earthquake in Egypt. Nat. Hazards 1994, 10, 261–274. [Google Scholar] [CrossRef] [Scilit]
- Thenhaus, P.C.; Sharp, R.V.; Celebi, M.; Ibrahim, A.; Van de Pol, H. Reconnaissance report on the 12 October 1992 Dahshour, Egypt, earthquake. In United States Geological Service (USGS) Survey Open File Report; U.S. Geological Survey: Reston, VA, USA, 1993; pp. 93–181. [Google Scholar]
- Mehanny, S.; El Howary, H. Assessment of RC moment frame buildings in moderate seismic zones: Evaluation of Egyptian seismic code implications and system configuration effects. Eng. Struct. 2010, 32, 2394–2406. [Google Scholar] [CrossRef] [Scilit]
- ECP-201; Egyptian Code for Calculating Loads and Forces in Structural and Masonry Works. HBRC: Cairo, Egypt, 2012.
- Elnashai, A.S.; Papanikolaou, V.; Lee, D. Zeus-NL—A System for Inelastic Analysis of Structures—User Manual; University of Illinois at Urbana-Champaign: Urbana, IL, USA, 2012. [Google Scholar]
- Mander, J.B.; Priestley, M.J.; Park, R. Theoretical stress-strain model for confined concrete. J. Struct. Eng. 1988, 114, 1804–1826. [Google Scholar] [CrossRef] [Scilit]
- Sousa, R.; Almeida, J.P.; Correia, A.A.; Pinho, R. Shake table blind prediction tests: Contributions for improved fiber-based frame modelling. J. Earthq. Eng. 2020, 24, 1435–1476. [Google Scholar] [CrossRef] [Scilit]
- Krawinkler, H.; Seneviratna, G. Pros and cons of a pushover analysis of seismic performance evaluation. Eng. Struct. 1998, 20, 452–464. [Google Scholar] [CrossRef] [Scilit]
- Mwafy, A.; Elnashai, A.S. Static pushover versus dynamic collapse analysis of RC buildings. Eng. Struct. 2001, 23, 407–424. [Google Scholar] [CrossRef] [Scilit]
- EN 1998-1:2004; Eurocode 8: Design of Structures for Earthquake Resistance. General Rules, Seismic Actions and Rules for Buildings. CEN: Brussels, Belgium, 2004.
- PEER. PEER Ground Motion Databas. Available online: http://peer.berkeley.edu/nga (accessed on 1 January 2026).
- ASCE/SEI-7; Minimum Design Loads and Associated Criteria for Buildings and Other Structures, ASCE/SEI 7-22. American Society of Civil Engineers: Reston, VA, USA, 2022.
- Kwon, O.S.; Elnashai, A.S. The effect of material and ground motion uncertainty on the seismic vulnerability curves of RC structure. Eng. Struct. 2006, 28, 289–303. [Google Scholar] [CrossRef] [Scilit]
- ASCE/SEI-41; Seismic Rehabilitation of Existing Buildings, ASCE/SEI 41-06. American Society of Civil Engineers: Reston, VA, USA, 2006.
- Ramamoorthy, S.K.; Gardoni, P.; Bracci, J.M. Seismic Fragility and Confidence Bounds for Gravity Load Designed Reinforced Concrete Frames of Varying Height. J. Struct. Eng. 2008, 134, 639–650. [Google Scholar] [CrossRef] [Scilit]
- Wen, Y.K.; Ellingwood, B.R.; Bracci, J. Vulnerability Function Framework for Consequence-Based Engineering; University of Illinois at Urbana-Champaign: Urbana, IL, USA, 2004. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.