Skip to Content
You are currently on the new version of our website. Access the old version .
BuildingsBuildings
  • Article
  • Open Access

9 November 2026

43 Pages

Numerical Analysis of a Novel Integral Composite Frame Beam with End-Plate Connection

,
,
,
and
1
College of Civil Engineering, Tongji University, Shanghai 200092, China
2
College of Civil Engineering, Fuzhou University, Fuzhou 350116, China
3
School of Architecture and Urban-Rural Planning, Fuzhou University, Fuzhou 350116, China
*
Authors to whom correspondence should be addressed.

Abstract

Composite frame beams utilize the composite action between steel beams and concrete slabs to improve bearing capacity and stiffness. However, the longitudinal slab reinforcement is generally interrupted by the steel column, limiting the slab contribution at the beam end under negative bending. Consequently, composite beams are often conservatively designed as bare steel beams, which may underestimate actual capacity and increase the risk of a strong-beam-weak-column mechanism. Existing solutions provide continuous force transfer by welding the slab reinforcement directly to the steel column. However, this detail may reduce the local stability and strength of the column flange and complicate on-site construction. To address these issues, this study proposes an integral composite frame beam with end-plate connections (ICFB-EP), in which the reinforcement is anchored to end plates bolted to the steel column. A finite element modelling approach validated against published experiments was used to investigate the monotonic response under positive and negative bending. Parametric analyses examined the effects of reinforcement diameter, concrete strength, column flange width, and steel beam dimensions. The ICFB-EP exhibited greater ultimate moment resistance and initial rotational stiffness than the corresponding bare steel beams, with approximately 25% higher ultimate moment resistance under negative bending in the comparisons examined. Reinforcement anchorage provided greater benefits under negative than positive bending. Failure was governed by tensile fracture and local compressive buckling of the lower beam flange under positive and negative bending, respectively. The existing calculation method overestimated the effective slab width at the beam end under positive bending; a revised expression was therefore proposed based on the numerical results to support the design of the ICFB-EP.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.