Abstract
The T-head square-neck one-side bolt (TSOB) provides a cost-effective and convenient fastening solution for hollow-section column (HSC) connections. However, its ultimate resistance, particularly when internal stiffeners are adopted, has not yet been sufficiently clarified. In this study, finite element simulations combined with theoretical derivation are used to evaluate the ultimate strength of TSOB bolted connections incorporating inner stiffeners. The results indicate that strain hardening considerably increases the connection resistance, with the ultimate strength being approximately 50–70% higher than the corresponding yield strength, indicating potential for optimization of material efficiency. The parametric analysis further reveals that for H-steel stiffeners, the ultimate resistance is mainly governed by the stiffener length, flange width, and flange thickness. Specifically, the length and flange width exhibit quadratic influences, whereas the flange thickness shows an approximately linear effect. For octagon-steel stiffeners, the resistance is primarily controlled by the stiffener length and wall thickness, with the length following a quadratic trend and the wall thickness showing a linear relationship, while the width of the connecting face has only a marginal influence. Based on the observed failure mechanisms, a unified calculation approach is developed by introducing reduction factors for the effective punching area, with values ranging from 0.67 to 0.78. The proposed model is verified against finite element results, and the average prediction error is less than 9%. The findings provide a practical basis for strength evaluation and configuration optimization of internally stiffened TSOB-bolted HSC connections.
1. Introduction
Steel structures are widely used in prefabricated buildings because of their high strength-to-weight ratio and efficient assembly process [1,2]. Beam-to-column joints in steel frames are generally realized using either welded or bolted connections. Welded joints are still commonly adopted for structures subjected mainly to static loading; nevertheless, under seismic action, their susceptibility to brittle fracture and the relatively low efficiency of material utilization may lead to safety concerns [3]. Compared with welded joints, bolted connections usually exhibit semi-rigid behavior and better energy dissipation capacity, which makes them more suitable for prefabricated steel structures requiring seismic resistance [4].
At present, most bolted beam-to-column connection systems have been developed for H-shaped steel columns, whereas their use in hollow section columns (HSCs) remains relatively limited. The main reason for this is that conventional high-strength bolts (CHBs) require access from both sides during installation, which is difficult to achieve in closed hollow sections. However, HSCs are structurally attractive because they can provide comparable flexural stiffness in two principal directions and thus show favorable seismic adaptability [5,6]. This mismatch between structural advantages and installation limitations highlights the need for reliable one-side bolting systems for HSC connections.
In recent years, one-side bolting technology has developed rapidly and has provided new possibilities for steel beam-to-HSC joints. These fasteners can be installed from one side of the column wall while maintaining mechanical performance close to that of conventional high-strength bolts under key loading conditions. Among the commonly studied systems, the Hollo-Bolt, Extended Hollo-Bolt (EHB), and Ajax One-side Bolt (AOB) are the most representative. Each of these systems improves the applicability of bolted joints in closed-section members through different anchorage or mechanical locking mechanisms.
For Hollo-Bolt connections, Ghobarah et al. [7] and Elghazouli et al. [8] investigated the joint stiffness, resistance, and cyclic behaviour, while Wang et al. [9,10,11] further examined the semi-rigid response, seismic performance, and progressive-collapse resistance of Hollo-Bolt endplate joints connected to hollow and concrete-filled steel tube columns. For EHB connections, Tizani et al. [12,13] evaluated their applicability in beam-to-CFST joints, whereas Pitrakkos et al. [14,15] investigated their tensile and combined tension-shear behavior. Mahmood et al. [16] proposed a strength and stiffness model for EHB joint components, and Cabrera et al. [17] studied the relationship between tightening torque and bolt preload. Regarding AOB connections, Thai et al. [18] and Waqas et al. [19] examined the flexural behavior, stiffness, and strength of endplate joints, while Hosseini et al. [20,21] investigated their static and fatigue shear performance. Overall, these studies have demonstrated that one-side bolting systems can provide feasible solutions for HSCs. However, their practical application may still be restricted by relatively complex anchorage mechanisms, specialized installation requirements, or proprietary components.
To address these limitations, Wang et al. [22] proposed the T-head square-neck one-side bolt (TSOB). The TSOB is similar in general form to a conventional high-strength bolt, but it uses a specially shaped T-head and square neck, as illustrated in Figure 1. Its installation does not require specially developed tools, which makes the connection more economical and convenient for engineering applications. The installation procedure for the TSOB is shown in Figure 2.
Figure 1.
T-head square-neck one-side bolt.
Figure 2.
Steps for installing TSOB (Note: the arrows indicate the displacements of the bolt or nut).
Wang et al. [22] conducted tensile tests on TSOB bolted T-stub-to-HSC connections and proposed a modified Gomes model for predicting their yield resistance. Subsequently, Sun et al. [23,24] investigated the flexural and cyclic behavior of TSOB endplate connections, demonstrating their satisfactory moment resistance, deformation capacity, and seismic performance. To improve the local force transfer in HSCs, Sun et al. [25,26] further examined internally stiffened TSOB beam-to-column connections under monotonic and cyclic loading, respectively, and confirmed the beneficial role of internal stiffeners in enhancing connection resistance and hysteretic performance. Hou et al. [27] investigated the bending behavior of TSOB-bolted T-stub joints and proposed a method for predicting their flexural resistance.
Nevertheless, studies on the ultimate strength of TSOB connections remain limited. Because of strain hardening, the ultimate resistance of the connection can be considerably higher than its yield resistance, and the use of ultimate strength may provide a more economical basis for design [28]. Previous studies [9,10] have also shown that when steel beams are directly connected to HSCs or CFSTs using one-side bolts, large stress concentration and local deformation may occur in the column wall within the joint region, thereby affecting the bearing capacity and stiffness of the connection. Therefore, inner stiffeners are required in the joint core region to improve the force transfer mechanism. Ref. [29] predicted the ultimate strength of TSOB bolted T-stub to HSC connections without considering the contribution of inner stiffeners. On this basis, the present study investigates the ultimate strength of TSOB-bolted T-stub-to-HSC connections with inner stiffeners using validated finite element models (FEMs).
2. Finite Element Model
In Eurocode 3 [30], the component method divides beam-to-column joints into tensile, compressive, and shear regions. The overall joint behavior is then evaluated by assembling the mechanical responses of individual components. In this study, attention is focused on the tensile region of TSOB connections with inner stiffeners, and the corresponding mechanical idealization is presented in Figure 3. Similar T-stub-based modelling approaches have been adopted in previous studies [29,31,32,33].
Figure 3.
Origin of T-stub model [29].
2.1. Establishment
The FEMs were developed in ABAQUS 2022 [34], with the geometric and mechanical characteristics of the specimens reproduced as accurately as possible. Two types of internal stiffeners were considered in this study, namely, an H-steel stiffener and an octagon-steel stiffener, as shown in Figure 4. Since the investigated connections are symmetric with respect to both the longitudinal and transverse central planes, only one-quarter of the whole connection was modelled, in order to improve computational efficiency. These two symmetry planes pass through the centerline of the bolt gauge distance and the centerline of the bolt pitch distance, respectively. The model was composed of four main parts: the HSC, T-stub, TSOBs, and internal stiffener, as illustrated in Figure 5.
Figure 4.
Geometric parameters of TSOB-bolted T-stub-to-HSC connection with inner stiffener (Note: the arrows indicate the displacements of the T-stub).
Figure 5.
FEMs built in finite element software ABAQUS 2022 [34].
All components were discretized using three-dimensional eight-node reduced-integration solid elements (C3D8R). Considering both numerical accuracy and computational cost, refined meshes were adopted in regions where stress concentration and large local deformation were expected, including the TSOBs and bolt-hole areas. The mesh size in these critical zones was set to 3 mm, while a relatively coarse mesh with a size of 8 mm was used in the remaining regions.
The boundary conditions applied in the FEMs are presented in Figure 6. Symmetric displacement constraints were assigned to the two symmetry planes. The end section of the HSC was coupled to a reference point, and all translational and rotational degrees of freedom of this reference point were restrained. Similarly, the end of the T-stub was coupled to another reference point, where the displacement loading was imposed. The loading direction was consistent with the axial direction of the T-stub web. The analyses were performed using the “Dynamic, Explicit” procedure in ABAQUS. The boundary conditions were defined in the initial step, while the displacement load was applied in the subsequent analysis step. In the contact property definition, hard contact was adopted in the normal direction, whereas tangential behavior was described using the Coulomb friction model. The friction coefficient was taken as 0.3, following the recommendation of the Code for Design of Steel Structures (GB 50017-2017) [35].
Figure 6.
Boundary conditions and mesh distribution.
Since the present study mainly focuses on the local deformation and failure of the HSC wall and the internal stiffener, the Johnson–Cook material model was adopted for these two components. Significant plastic deformation and strain hardening may develop in the bolt-hole region of the HSC and stiffener at the ultimate state; therefore, a constitutive model capable of representing their nonlinear response at relatively large strains was required. By contrast, in the present models, the T-stub and TSOBs mainly function as load-transfer components. Within the investigated parameter range, no dominant failure or severe strain localization was observed in these components. Therefore, a bilinear elastic–plastic material model was adopted for the T-stub and TSOBs, which was considered sufficient to represent their mechanical response while improving computational efficiency.
2.2. Validation
2.2.1. Introduction of Tests
The reliability of the proposed FEM was examined using the tensile test results reported by Wang et al. [22]. In their study, TSOB-bolted T-stub-to-HSC connections were tested under tensile loading. As illustrated in Figure 7, each specimen was mainly composed of an HSC, a T-stub, and TSOBs. The material properties adopted in the present numerical models were consistent with those used in the validated TSOB connection model reported in ref. [29]. The HSC and internal stiffeners were assigned the material properties of the 7 mm HSST wall, with a measured yield strength of 380.19 Mpa and an ultimate strength of 501.27 MPa. The T-stub was assigned the material properties of the 30 mm T-stub flange, with a measured yield strength of 274.82 Mpa and an ultimate strength of 370.06 MPa. The TSOBs were fabricated from 40Cr alloy steel and were modelled using a yield strength of 740.09 Mpa and an ultimate strength of 833.49 Mpa. In the present validation, two specimens showing HSC wall yielding accompanied by bolt-hole punching were selected for comparison. These two specimens had almost identical geometric dimensions except for the bolt-hole arrangement.
Figure 7.
Specimen in ref. [22].
The T-stub flange had a cross-section of 200 mm × 280 mm and a thickness of 30 mm. The HSC section was 200 mm × 200 mm, with a wall thickness of 7 mm, a total length of 1000 mm, and an external corner radius of 20 mm. The bolt gauge distance and pitch distance were 100 mm and 130 mm, respectively. The bolt hole were both designed to be 2 mm larger than the bolt head. The bolt hole pattern included vertical and horizontal layouts, as shown in Figure 8. The specimen labels followed the format “bolt-hole type and diameter–HSC wall thickness–T-stub flange thickness”, where “TH” and “TV” denote horizontal and vertical bolt-hole arrangements, respectively.
Figure 8.
Bolt hole layouts for TSOBs [29].
2.2.2. Results of Validation
The comparison between the FEMs and the experimental results is presented in Figure 9 and Table 1. The numerical load–displacement curves generally agree well with the corresponding test curves, indicating that the model can reasonably capture the tensile response of the connection. As shown in Figure 10, the simulated failure patterns are also consistent with those observed in the tests. Both the experimental and numerical results show pronounced out-of-plane plastic deformation of the HSC connection face, bolt-hole punching, and inward deformation of the HSC side walls.
Figure 9.
Comparison of load–displacement curves of specimens in ref. [22].
Table 1.
Characteristic values of tests and FEMs.
Figure 10.
Comparison of failure modes of specimens in ref. [22].
According to Table 1, the ultimate strength predicted by the FEM was 283.15 kN for specimen TV20-7-30, compared with the experimental value of 318.07 kN, giving an error of −10.98%. For specimen TH20-7-30, the predicted ultimate strength was 324.38 kN, while the test value was 338.24 kN, corresponding to an error of −4.10%. The remaining differences between the FEM and test results may be attributed to several factors. The material parameters adopted in the numerical model were based on representative material data and could not fully reflect the variability of the actual steel properties among individual specimens. In addition, the contact interaction and friction coefficient were simplified in the FEM, which may affect the local load transfer and slip behavior between the TSOB, T-stub, and HSC. Nevertheless, the numerical load–displacement responses and failure modes agree well with the test observations, and the average error of −7.54% indicates that the developed FEM has sufficient accuracy for the subsequent parametric analysis.
3. Parametric Analysis
The ultimate strength of TSOB-bolted T-stub-to-HSC connections strengthened with internal stiffeners was further examined through parametric analysis. The investigated parameters were mainly associated with the configuration of the internal stiffener. Two stiffener forms were considered in this study: H-steel stiffeners and octagon-steel stiffeners. For the H-steel stiffener, the main parameters included the stiffener length lh, flange width th,f, flange thickness th,w, and section form, as indicated in Figure 4a. For the octagon-steel stiffener, the parameters included the stiffener length lo, connecting face width W, and wall thickness to,w, as shown in Figure 4b. In addition, the influence of the contact condition between the HSC and the internal stiffener was also considered.
In all FEMs used for the parametric study, the T-stub flange thickness was set to 30 mm to reduce the deformation of the T-stub. Therefore, the T-stub mainly served to transfer the applied load to the HSC, TSOBs, and inner stiffener. The HSC had a section of 200 mm × 200 mm, a wall thickness of 7 mm, a length of 600 mm, and an external corner radius of 20 mm. The bolt pitch distance was 130 mm, while two gauge distances, namely 70 mm and 100 mm, were considered. The material properties adopted in the parametric analysis were consistent with those used in the validated FEM. Unless otherwise specified, a 2 mm installation gap was reserved on the side of the internal stiffener without bolts. Horizontal bolt-hole layouts were adopted in this study because previous research [22] indicates that such an arrangement provides higher ultimate strength than a vertical layout. The FEMs in the parametric analysis were generally named according to the format “parameter name–parameter value”. For instance, “lh-600” denotes the model in which only the H-steel stiffener length was changed to 600 mm, while the other parameters remained unchanged within the same parameter group.
3.1. Effect of H-Steel Stiffener
3.1.1. Effect of Length lh
The influence of the H-steel stiffener length on the ultimate strength of the TSOB connection was studied, as shown in Figure 11 and Table 2. The considered values of lh ranged from 250 mm to 600 mm. When the stiffener length was smaller than 500 mm, the ultimate strength of the connection generally increased with increasing lh, and the growth rate also became slightly larger. This indicates that, within this range, the relationship between the ultimate strength and the H-steel stiffener length can be approximately described by a quadratic trend.
Figure 11.
Effect of length lh on connection bearing capacity.
Table 2.
Ultimate strength with different lengths lh.
However, when the stiffener length exceeded 500 mm, the ultimate strength began to decrease as lh continued to increase. This phenomenon is mainly related to the boundary restraint of the HSC. As the H-steel stiffener comes close to the ends of the HSC, the displacement and rotational constraints at both ends of the column begin to affect the deformation of the stiffener more significantly. The deformation patterns shown in Figure 12 also confirm this influence. For a relatively short H-steel stiffener, the flange tends to move inward toward the web under the out-of-plane deformation of the HSC connection face. When the stiffener length approaches the full length of the HSC, this inward movement is restrained because the end regions of the HSC experience limited deformation. As a result, the strengthening effect of the H-steel stiffener is not fully mobilized.
Figure 12.
The deformation with different lengths lh.
Therefore, in practical design, the length of the H-steel stiffener should not be taken as equal to the full HSC length. For the models investigated in this subsection, failure occurred mainly in the HSC and H-steel stiffener. The HSC failure mode remained wall yielding accompanied by bolt-hole punching, while the H-steel stiffener exhibited flange deformation together with local punching around the bolt holes.
3.1.2. Effect of Flange Width th,f
The influence of the H-steel stiffener flange width on the ultimate strength of the TSOB connection is presented in Figure 13 and Table 3. In this group of models, th,f varied from 120 mm to 160 mm. The results show that changing the flange width had a noticeable effect on the tensile resistance of the connection. The ultimate strength increased from 669.26 kN to 699.07 kN as the flange width increased, with a difference of 29.81 kN between the minimum and maximum values.
Figure 13.
Effect of flange width th,f on connection bearing capacity.
Table 3.
Ultimate strength with different flange widths th,f.
It can also be observed that the increase in ultimate strength became more pronounced with increasing th,f. Therefore, the relationship between the ultimate strength and the flange width of the H-steel stiffener may be approximately represented by a quadratic trend. For all models in this group, the main deformation still developed in the HSC and the H-steel stiffener. The HSC exhibited wall yielding accompanied by bolt-hole punching, while the H-steel stiffener showed local punching around the bolt holes together with inward movement of the flange toward the web.
3.1.3. Effect of Flange Thickness th,w
Figure 14 shows the effect of the H-steel stiffener flange thickness on the ultimate strength of the TSOB connection. The flange thickness was increased from 3 mm to 11 mm, and the corresponding numerical results are summarized in Table 4. Compared with the flange width, the flange thickness had a more significant influence on the connection resistance. As th,w increased, the ultimate strength increased almost linearly. Specifically, when the flange thickness increased from 3 mm to 11 mm, the ultimate strength was enhanced by 364.96 kN.
Figure 14.
Effect of flange thickness th,w on connection bearing capacity.
Table 4.
Ultimate strength with different flange thicknesses th,w.
The deformation and failure characteristics of this group were generally consistent with those observed in the previous parameter studies. Local deformation occurred mainly in the HSC wall and the H-steel stiffener. The HSC failure was still characterized by wall yielding and bolt-hole punching. Meanwhile, the flange of the H-steel stiffener moved toward the web, and local punching was also observed around the bolt-hole region of the stiffener.
For comparison, additional unstiffened TSOB connection models were established and are analyzed in the present study. In these models, the internal stiffener was removed. The comparison in Figure 15 further shows that the strengthening effect of the H-steel stiffener was closely related to the HSC wall thickness. When the HSC wall thickness was relatively small, the connection with the H-steel stiffener had a higher ultimate strength than the corresponding connection without an inner stiffener. This is because the dominant failure mode in this case was governed by HSC wall yielding and bolt-hole punching, and the stiffener could effectively improve the resistance of the locally deformed column wall. However, when the HSC wall thickness became larger, the failure tended to shift toward the TSOB itself. In this situation, the ultimate strength was controlled mainly by the bolt capacity, and increasing the HSC wall thickness had limited influence on the connection resistance.
Figure 15.
Comparison of ultimate strength with and without H-steel stiffener.
For HSC wall thicknesses of 10 mm, 12 mm, and 14 mm, the ultimate strength of the connection without an inner stiffener was higher than that of the connection with an H-steel stiffener, and the difference became larger as the wall thickness increased. This phenomenon may be attributed to the slight relative slip between the HSC and the H-steel stiffener under tensile loading. By contrast, an HSC with an increased wall thickness behaved as a continuous single component, which is more favorable for resisting local deformation.
3.1.4. Effect of Section Shape
The section configuration of the internal stiffener also affects the load-transfer mechanism of the TSOB connection. For the H-steel stiffener, the two flanges connected to the beam side can transfer the tensile force toward the opposite side of the HSC in a relatively uniform manner. Nevertheless, this type of stiffener requires additional installation space, which may increase the difficulty of assembly in practical applications.
To evaluate the influence of the shape of the stiffener section, the performance of the H-steel stiffener was compared with that of a cross-steel stiffener, as shown in Figure 16. The corresponding load–displacement curves are presented in Figure 17. It can be seen that the ultimate strength of the connection with the H-steel stiffener was slightly higher than that of the connection with the cross-steel stiffener, with a difference of 18.16 kN.
Figure 16.
TSOB-bolted T-stub-to-HSC connection with cross-steel stiffener (Note: the arrows indicate the displacements of the T-stub).
Figure 17.
Effect of section shape on connection bearing capacity.
The ultimate strengths provided by the two types of inner stiffeners were generally close, indicating that both section forms can effectively enhance the connection resistance. However, the displacement corresponding to the peak load was smaller for the H-steel stiffener than for the cross-steel stiffener. This may be because the cross-steel stiffener can better restrain the deformation of the HSC side walls, leading to a larger deformation capacity before the connection reaches its maximum strength.
Based on the above comparison, the H-steel stiffener can be regarded as a more suitable section form for the internally stiffened TSOB connection considered in this study, because it provides slightly higher ultimate strength and enables a more direct load-transfer path.
3.2. Effect of Octagon-Steel Stiffener
3.2.1. Effect of Length lo
The influence of the octagon-steel stiffener length on the ultimate strength of the TSOB connection was investigated, as presented in Figure 18 and Table 5. In this group of models, the length lo was varied from 200 mm to 600 mm. The results indicate that the ultimate strength generally increased with increasing stiffener length, although the growth rate gradually decreased and the curve tended to become flatter. Therefore, the relationship between the ultimate strength and the length of the octagon-steel stiffener can be approximately described by a quadratic trend.
Figure 18.
Effect of length lo on connection bearing capacity.
Table 5.
Ultimate strength with different lengths lo.
For the models considered in this subsection, failure mainly occurred in the HSC and the octagon-steel stiffener. The HSC still exhibited wall yielding accompanied by bolt-hole punching. The octagon-steel stiffener showed a similar local failure pattern, mainly characterized by yielding of the connecting face and punching around the bolt holes.
Unlike the H-steel stiffener, the octagon-steel stiffener did not show an evident reduction in ultimate strength when its length approached the full length of the HSC. This suggests that the end restraint of the HSC had a relatively limited influence on the mechanical response of the octagon-steel stiffener. The difference can be explained by the different section forms of the two stiffeners. The H-steel stiffener is an open-section member, and its flanges are more sensitive to the deformation and boundary conditions of the HSC. As the stiffener length changes, the flange deformation also changes accordingly. Since no side plates are provided to restrain the flange movement, the HSC end regions can significantly affect the deformation of the H-steel stiffener.
In contrast, the octagon-steel stiffener is a closed-section component. Its deformation behavior is closer to that of the HSC itself. Under the tensile action transmitted by the TSOBs, the main deformation is concentrated in the connecting face, while the deformation near the stiffener ends remains relatively small, as shown in Figure 19. This closed-section characteristic explains why the length of the octagon-steel stiffener has a more stable influence on the connection strength.
Figure 19.
The deformation with different lengths lo.
3.2.2. Effect of Connecting Face Width W
The effect of the connecting face width of the octagon-steel stiffener on the ultimate strength of the TSOB connection is shown in Figure 20 and Table 6. In this group of models, the connecting face width W was varied from 120 mm to 160 mm. The results indicate that changing W had only a limited influence on the ultimate strength of the connection. The difference between the maximum and minimum ultimate strengths was 12.17 kN, while the average value and standard deviation were 642.60 kN and 4.97 kN, respectively.
Figure 20.
Effect of connecting face width W on connection bearing capacity.
Table 6.
Ultimate strength with different connecting face widths W.
This small variation suggests that the connecting face width of the octagon-steel stiffener was not a governing parameter for the ultimate resistance of the TSOB connection within the investigated range. For all models in this group, failure mainly occurred in the HSC and the octagon-steel stiffener. The HSC failure mode was still characterized by wall yielding accompanied by bolt-hole punching. For the octagon-steel stiffener, yielding of the connecting face and punching around the bolt holes were observed.
3.2.3. Effect of Wall Thickness to,w
Figure 21 presents the influence of the octagon-steel stiffener wall thickness on the ultimate strength of the TSOB connection. The wall thickness to,w was increased from 3 mm to 11 mm, and the corresponding results are listed in Table 7. Unlike the connecting face width, the wall thickness had a significant effect on the connection resistance. The ultimate strength increased almost linearly as to,w increased. When the wall thickness increased from 3 mm to 11 mm, the ultimate strength rose from 494.89 kN to 908.66 kN, with an increase of 413.77 kN.
Figure 21.
Effect of wall thickness to,w on connection bearing capacity.
Table 7.
Ultimate strength with different wall thicknesses to,w.
The failure locations of this group were mainly concentrated in the HSC and the octagon-steel stiffener. The HSC continued to fail through wall yielding and bolt-hole punching. The octagon-steel stiffener showed yielding of the connecting face together with local punching around the bolt holes. The improvement in ultimate strength with increasing wall thickness can be attributed to the enlargement of the effective punching area around the bolt holes in the octagon-steel stiffener, which enhanced its resistance to local failure.
The ultimate strengths of connections with octagon-steel stiffeners were further compared with those of connections without inner stiffeners but with equivalent wall thicknesses, as shown in Figure 22. When the wall thicknesses were 16 mm and 18 mm, failure of the unstiffened connections occurred in the TSOBs, which was beyond the main concern of this study. Therefore, only the connections with wall thicknesses of 10 mm, 12 mm, and 14 mm were compared. For these cases, the ultimate strength of the connection without an inner stiffener was higher than that of the connection with an octagon-steel stiffener, and the difference increased as the wall thickness became larger.
Figure 22.
Comparison of ultimate strength with and without octagon-steel stiffener.
This phenomenon may be related to the slight relative slip between the octagon-steel stiffener and the HSC under tensile loading. By contrast, an HSC with an equivalent increased wall thickness behaves as an integral single component, which allows a more continuous force-transfer path and thus provides greater resistance.
Overall, the results indicate that the H-steel stiffener can effectively improve the load-transfer path between the TSOBs and the HSC wall and restrain the out-of-plane deformation of the connection face. Consequently, the development of local HSC wall yielding and bolt-hole punching is delayed, resulting in an enhanced ultimate resistance of the connection. The strengthening effect is mainly governed by the stiffness and geometric configuration of the stiffener, particularly the flange thickness.
3.3. Effect of Contact Relationship
The influence of the contact condition between the HSC and the internal stiffener on the ultimate strength of the TSOB connection was also examined. In practical construction, the inner stiffener must usually be fixed inside the HSC before the connection is assembled, so as to ensure its position during installation. Plug welding is a commonly used method for this purpose. In this method, narrow slots are first opened on the back face of the HSC. The inner stiffener is then pushed into the joint region using a long-rod hydraulic jack and finally welded to the HSC through the prepared slots [27].
The H-steel stiffener was selected as a representative case to evaluate the effect of different contact treatments. The load–displacement responses of the two models are compared in Figure 23. These two models had the same geometric dimensions, and no installation gap was reserved between the HSC and the inner stiffener. The only difference was the contact definition at the back side of the inner stiffener. In one model, general contact was adopted between the inner stiffener and the HSC, whereas in the other model, the two components were connected using a “tie” constraint.
Figure 23.
Effect of contact relationship on connection bearing capacity.
As shown in Figure 23, the model with the “tie” constraint exhibited a lower ultimate strength than the model using general contact. The reduction in ultimate strength was 41.16 kN, corresponding to approximately 5.96%. This result indicates that plug welding may slightly reduce the tensile resistance of the connection, but the reduction is limited. Therefore, considering the requirements of practical installation, plug welding can still be regarded as an acceptable fixing method for the inner stiffener.
It should be noted that the internally stiffened TSOB connections investigated in the present study have not yet been directly verified by dedicated experiments. The numerical models were developed by introducing internal stiffeners into the validated unstiffened TSOB connection model while retaining the same TSOB geometry, material properties, contact definition, boundary conditions, and governing HSC wall failure mechanism. Therefore, the present results provide a comparative numerical assessment of the strengthening effects of the H-steel and octagon-steel stiffeners. Further experimental studies are required to validate the detailed deformation behavior and resistance prediction of internally stiffened TSOB connections.
4. Calculation of Ultimate Strength
4.1. Ultimate Strength of TSOB Connections
For TSOB connections strengthened with internal stiffeners, the main failure components are the HSC wall and the inner stiffener. The HSC fails through wall yielding accompanied by bolt-hole punching, which is consistent with the failure mechanism observed in TSOB connections without internal stiffeners. Although the two stiffener types showed some differences in local deformation, their failure can generally be described as bolt-hole punching combined with connecting face deformation. Therefore, the ultimate strength of internally stiffened TSOB connections is mainly governed by punching failure around the bolt holes in both the HSC and the inner stiffener.
Based on Eurocode 3 [30], the punching shear resistance around a bolt hole can be evaluated using Equation (1).
where Bp,Rd denotes the design punching shear resistance of the bolt head or nut; dm is the smaller mean value of the across-points and across-flats dimensions of the bolt head or nut, tp represents the thickness of the plate under the bolt head or nut; fu is the ultimate tensile strength of the HSC material, and γM2 is the partial safety factor.
However, Equation (1) was originally developed for conventional high-strength bolts and is not directly suitable for TSOB connections [29]. This is mainly because the TSOB has a different bolt-head shape and bolt-hole geometry from a conventional high-strength bolt, resulting in a different clamping area and punching mechanism. Therefore, a modified calculation method is required in order to evaluate the ultimate strength of TSOB connections with inner stiffeners.
In ref. [29], the ultimate strength of TSOB connections without internal stiffeners was predicted by considering the punching resistance around the bolt holes. The ultimate resistance can be expressed as follows:
where Fu denotes the ultimate strength of the TSOB connection, Aev is the effective punching area of the bolt holes in the HSC, and fu represents the ultimate tensile strength of the HSC material. The effective punching area can be obtained from the theoretical punching area by introducing a reduction factor, as follows:
where Av is the theoretical punching area of the bolt holes, and χ is the reduction factor. The theoretical punching area can be derived from the geometric relationship shown in Figure 24, as expressed in Equation (4).
where dh is the bolt-hole diameter, ra is the aspect ratio of the bolt head, es is the installation clearance, and tw is the wall thickness of the HSC. For TSOB connections without internal stiffeners, the reduction factor χ is related to the HSC parameters and can be calculated using Equation (5).
where ms denotes the side margin of the bolt hole, g is the bolt gauge distance, and the other symbols have the same meanings as defined above.
Figure 24.
Details of TSOB and bole hole [29].
Although Equations (2)–(5) can provide reasonable predictions for TSOB connections without inner stiffeners, they are not directly applicable to connections strengthened with internal stiffeners. This is because the load-bearing mechanism of the stiffened connection is governed not only by punching failure in the HSC wall, but also by punching failure in the inner stiffener. Therefore, the ultimate strength of the internally stiffened TSOB connection should be evaluated by considering the combined contribution of the HSC and the stiffener, as expressed in Equation (6).
where Aev,H and Aev,S are the effective punching areas of the bolt holes in the HSC and inner stiffener, respectively; fu,H and fu,S are the ultimate tensile strengths of the HSC and inner stiffener materials, respectively. The effective punching areas Aev,H and Aev,S can still be determined based on Equations (3) and (4). However, the reduction factor χ in the internally stiffened connection cannot be directly calculated using Equation (5) and thus needs to be re-evaluated.
When punching failure occurs, the bolt holes in both the HSC and the inner stiffener experience local expansion due to surrounding plastic deformation. This expansion reduces the actual contact area between the T-head of the TSOB and the edge of the bolt hole. The reduction factor χ is therefore introduced to describe the ratio between these two areas.
The deformation characteristics around the bolt holes in the inner stiffener are generally consistent with those in the HSC at the ultimate state. Accordingly, the same reduction factor is assumed for the bolt holes in the HSC and the inner stiffener. To determine the appropriate value of χ, the finite element results were further analyzed. The empirical reduction factors χe for connections with H-steel stiffeners and octagon-steel stiffeners are summarized in Table 8 and Table 9, respectively. The material of the inner stiffener was taken to be the same as that of the HSC, and the ultimate tensile strength fu was 501.27 MPa according to ref. [22]. In these tables, Aev represents the combined effective punching area of the HSC and inner stiffener, while Av denotes the corresponding combined theoretical punching area. The results show that χe remains within a relatively stable range, varying from 0.691 to 0.777 for the H-steel stiffener and from 0.670 to 0.741 for the octagon-steel stiffener.
Table 8.
Empirical values of the reduction factor χe for TSOB connections with H-steel stiffener.
Table 9.
Empirical values of the reduction factor χe for TSOB connections with octagon-steel stiffener.
To further establish a reduction factor with broader applicability, the influence of each stiffener parameter on χ was examined separately. The following subsections discuss the reduction factor for H-steel stiffeners and octagon-steel stiffeners, respectively.
4.1.1. The Reduction Factor χ for H-Steel Stiffener
For TSOB connections with H-steel stiffeners, the reduction factor χ is shown in Equation (7).
The reduction factor for the H-steel stiffener can be decomposed into several parts, as expressed in Equation (8).
where χlh, χhf, χhw, and χHSC represent the effects of the H-steel stiffener length, flange width, flange thickness, and HSC-related parameters on the reduction factor, respectively. It should be noted that these terms are introduced as normalized empirical influence terms for identifying the relative effects of individual parameters, rather than as independent physical area ratios. The ultimate strength Fu in the following intermediate expressions is used only as the numerical response variable for establishing parameter-dependent relationships under the condition that the remaining variables are kept constant.
When the influence of H-steel stiffener length on the reduction factor χ is evaluated, the effects of the remaining parameters can be regarded as constant. Based on Equations (7) and (8), the length-related component χlh can therefore be expressed as follows:
where C1 is a constant.
The corresponding ultimate strengths Fu were obtained from the FEMs and are listed in Table 2. As discussed above, the length of the H-steel stiffener has a clear influence on the ultimate resistance of the TSOB connection. Since it is recommended that the stiffener length is not close to the full HSC length in practical applications, cases in which the H-steel stiffener approaches the HSC length are not considered in the fitting process. As shown in Figure 25, the relationship between Fu and lh can be approximately described by a quadratic function. The fitted expression is given as follows:
Figure 25.
Fitting of Fu and lh.
By substituting Equation (10) into Equation (9), the length-related reduction factor χlh can be obtained as follows:
The influence of the H-steel stiffener flange width on the reduction factor was also examined. Similarly, when the flange width th,f was taken as the investigated variable, the effects of the other parameters were treated as constants. Thus, according to Equations (7) and (8), the flange-width-related component χhf can be written as follows:
where C2 is a constant.
The finite element ultimate strengths corresponding to different flange widths are summarized in Table 3. Figure 26 shows that th,f has a noticeable influence on Fu. The numerical results indicate that Fu varies approximately according to a quadratic relationship with the flange width. The fitted equation between Fu and th,f is expressed as follows:
Figure 26.
Fitting of Fu and th,f.
Substituting Equation (13) into Equation (12), the reduction factor component associated with the flange width can be calculated as follows:
The flange thickness of the H-steel stiffener was also considered in the derivation of the reduction factor. When th,w was selected as the variable, the influence of other parameters was again assumed to remain constant. The flange-thickness-related component χhw can therefore be expressed using Equations (7) and (8).
where C3 is a constant.
The values of Fu obtained from the FEMs are given in Table 4. As shown in Figure 27, the flange thickness has a significant effect on the ultimate strength of the connection. Different from lh and th,f, the relationship between Fu and th,w is approximately linear within the investigated range. The fitted expression is as follows:
Figure 27.
Fitting of Fu and th,w.
By substituting Equation (16) into Equation (15), the flange-thickness-related reduction factor can be written as follows:
Considering the combined influence of the H-steel stiffener length, flange width, flange thickness, and the HSC-related parameters, the overall reduction factor χ can be expressed as follows:
where A is a constant.
The influence of the HSC-related parameters on the reduction factor has already been considered in ref. [29]. Therefore, χHSC can be calculated as follows:
The value of A is obtained from the empirical values of the reduction factor χe in Table 8, taking the minimum value. Rather than adopting the average value or an unconstrained fitted value, the minimum empirical value is selected to ensure a conservative prediction of the connection resistance. Since A directly affects the calculated reduction factor χ, a smaller value of A results in a lower effective punching area and, consequently, a lower predicted ultimate strength. This treatment reduces the possibility of overestimating the resistance of TSOB connections with H-steel stiffeners within the investigated parameter range. Further, the reduction factor χ can be calculated by the following equation:
Equation (20) is mainly applicable to TSOB connections in which the internal stiffener is an H-steel stiffener. For this type of connection, the HSC failure mode is still characterized by wall yielding accompanied by bolt-hole punching. In addition, the H-steel stiffener shows local punching around the bolt holes, and its flange tends to move inward toward the web. In Equation (20), the added coefficient is an empirical calibration term obtained from the finite element results for H-steel stiffened connections. The geometric parameters in this expression are expressed in millimeters.
4.1.2. The Reduction Factor χ for Octagon-Steel Stiffener
For TSOB connections strengthened with octagon-steel stiffeners, the reduction factor χ expressed in Equation (21).
The reduction factor for the octagon-steel stiffener can be divided into several components, as follows:
where χlo, χW, χow, and χHSC denote the effects of the octagon-steel stiffener length, connecting face width, wall thickness, and HSC-related parameters on the reduction factor, respectively.
When the length lo of the octagon-steel stiffener is selected as the investigated variable, the effects of the other parameters can be regarded as constants. According to Equations (21) and (22), the length-related component χlo can therefore be written as follows:
where C4 is a constant.
The ultimate strengths Fu corresponding to different values of lo were obtained from the finite element results listed in Table 5. As shown in Figure 28, the length of the octagon-steel stiffener has a clear influence on the ultimate strength of the TSOB connection. The relationship between Fu and lo can be approximately described by a quadratic function, and the fitted expression is given as follows:
Figure 28.
Fitting of Fu and lo.
Substituting Equation (24) into Equation (23), the reduction factor component associated with the stiffener length can be obtained as follows:
In exploring the effect of the connecting face width of the octagon-steel stiffener on the reduction factor χ, the other parameters can be treated as a constant, and χW is given by Equations (21) and (22) as follows:
The influence of the connecting face width W was then considered. When W is treated as the variable, the effects of the remaining parameters on χ are assumed to be constant. Thus, the width-related component χW can be expressed as follows:
where C5 is a constant.
The finite element values of Fu for different connecting face widths are summarized in Table 6. As indicated in Figure 29, the connecting face width of the octagon-steel stiffener has no obvious influence on the ultimate strength within the investigated range. The fitted curve between Fu and W is therefore close to a horizontal line, and the corresponding expression can be written as follows:
Figure 29.
Fitting of Fu and W.
By substituting Equation (27) into Equation (26), the reduction factor component related to the connecting face width is obtained as follows:
The wall thickness to,w of the octagon-steel stiffener was also introduced into the reduction factor model. When to,w was selected as the variable, the effects of the other parameters were kept unchanged. Based on Equations (21) and (22), the wall-thickness-related component χow can be expressed as follows:
where C6 is a constant.
The ultimate strengths obtained from the FEMs are presented in Table 7. Figure 30 shows that the wall thickness of the octagon-steel stiffener significantly affects the ultimate strength of the connection. Within the studied range, Fu increases approximately linearly with to,w. The fitted equation between Fu and to,w is given as follows:
Figure 30.
Fitting of Fu and to,w.
Substituting Equation (30) into Equation (29), the wall-thickness-related reduction factor can be calculated as follows:
By combining the effects of stiffener length, connecting face width, stiffener wall thickness, and HSC-related parameters, the overall reduction factor χ for the octagon-steel stiffener can be written as follows:
where B is a constant. The term χHSC can be calculated using Equation (19).
The value of B is determined from the empirical reduction factors χe listed in Table 9. To obtain a conservative prediction, the minimum empirical value is adopted. Accordingly, the final expression for calculating the reduction factor of TSOB connections with octagon-steel stiffeners is obtained as follows:
Equation (33) is mainly applicable to TSOB connections in which the internal stiffener is an octagon-steel stiffener. For this type of connection, the HSC failure mode remains wall yielding accompanied by bolt-hole punching, while the octagon-steel stiffener fails mainly through yielding of the connecting face and local punching around the bolt holes. The added coefficient in Equation (33) is an empirical calibration term obtained from the finite element results for octagon-steel stiffened connections. Its dimensional form corresponds to the adopted unit of millimeters for the geometric parameters, ensuring that the final reduction factor χ remains dimensionless.
4.2. Validation of Equations
To verify the applicability of the proposed equations for predicting the ultimate strength of TSOB connections with inner stiffeners, additional FEMs were established with various geometric parameters. The detailed parameters of these models are listed in Table 10 and Table 11. The specimens were named according to the format “type of inner stiffener–number”, where “H” represents the H-steel stiffener and “O” represents the octagon-steel stiffener.
Table 10.
Parameters of specimens with H-steel stiffener used to validate the equation.
Table 11.
Parameters of specimens with octagon-steel stiffener used to validate the equation.
The ultimate strengths calculated using the proposed equations were compared with the corresponding finite element results. In addition, the predictions obtained from Equation (1) in Eurocode 3 [30] were also included for comparison. The comparison results for the H-steel stiffener and octagon-steel stiffener are summarized in Table 12 and Table 13, respectively, and the overall comparison is illustrated in Figure 31.
Table 12.
Comparison of FEM results and theoretical predictions for specimens with H-steel stiffener.
Table 13.
Comparison of FEM results and theoretical predictions for specimens with octagon-steel stiffener.
Figure 31.
Comparison of FEMs and theoretical predictions.
For the TSOB connections with H-steel stiffeners, the proposed equation provided relatively accurate and conservative predictions. The average error was −6.30%, with a standard deviation of 0.06, and the maximum error was −16.73%. For the connections with octagon-steel stiffeners, the average error was −8.60%, the standard deviation was 0.03, and the maximum error was −12.04%. The deviations may be attributed to the simplified unified reduction-factor expressions, which cannot fully account for the local stress redistribution, deformation compatibility, and contact interaction between the HSC and the internal stiffener for all geometric configurations. Further experimental and numerical investigations are needed to refine the proposed model and improve its applicability. These results indicate that the proposed method can reasonably estimate the ultimate strength of TSOB connections strengthened with different types of internal stiffeners.
By contrast, the calculation method given in Eurocode 3 [30] generally overestimated the ultimate strength of the investigated TSOB connections. This is mainly because Equation (1) was developed for conventional high-strength bolts, while the TSOB has a different T-head geometry and bolt-hole configuration. As a result, the actual clamping and punching areas of the TSOB differ from those assumed in the Eurocode 3 equation.
Overall, the proposed equations show good agreement with the finite element results, as also reflected in Figure 31. Therefore, the proposed calculation method can be used to evaluate the ultimate strength of TSOB-bolted T-stub-to-HSC connections with inner stiffeners within the parameter ranges considered in this study.
5. Conclusions
In this study, the ultimate strength of TSOB-bolted T-stub-to-HSC connections strengthened with internal stiffeners was investigated through finite element analysis and theoretical derivation. Two stiffener configurations, namely an H-steel stiffener and an octagon-steel stiffener, were considered. The effects of key geometric parameters on the connection resistance were examined, and calculation equations for the ultimate strength were developed based on the observed failure mechanisms. The main conclusions can be summarized as follows:
- (1)
- The validated FEM reasonably reproduced the load–displacement response and the characteristic failure mode of the tested TSOB connections. For the internally stiffened models, failure was mainly governed by HSC wall yielding accompanied by bolt-hole punching, while local deformation and punching also developed in the internal stiffener near the bolt-hole region.
- (2)
- Internal stiffeners improved the local load-transfer path between the TSOBs and the HSC wall and restrained the out-of-plane deformation of the connection face. Their strengthening effect was more evident when the HSC wall was relatively thin, because the connection resistance was then mainly governed by local wall yielding and bolt-hole punching.
- (3)
- For H-steel stiffeners, flange thickness had the most significant influence on the ultimate resistance, while stiffener length and flange width showed relatively moderate effects. For octagon-steel stiffeners, stiffener length and wall thickness were the principal governing parameters, whereas the connecting face width had only a limited influence within the investigated range.
- (4)
- The numerical load–displacement responses showed a clear post-yield strengthening stage. The ultimate resistance was approximately 50–70% higher than the corresponding yield resistance, indicating that strain hardening and the progressive mobilization of the HSC wall and internal stiffener made a significant contribution to the ultimate behavior of the connections.
- (5)
- Unified calculation methods were developed for the H-steel and octagon-steel stiffener configurations by introducing reduction factors for the effective punching area. The proposed equations provided conservative predictions of the FEM results. It should be noted that the internally stiffened configurations investigated in this study have not yet been directly validated by dedicated experiments. Future work should therefore focus on experimental verification of internally stiffened TSOB connections and further investigation of their deformation capacity and cyclic behavior.
Author Contributions
Conceptualization, L.S.; Methodology, S.L., J.K. and F.N.; Software, J.K.; Validation, S.L., J.K. and F.N.; Formal analysis, S.L.; Investigation, S.L. and S.W.; Resources, L.S.; Data curation, S.L., J.K. and F.N.; Writing—original draft, S.L.; Writing—review & editing, S.W. and L.S.; Visualization, L.S.; Supervision, S.W. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.
Data Availability Statement
The original contributions presented in the study are included in the article, further inquiries can be directed to the corresponding author.
Conflicts of Interest
The authors declare no conflict of interest.
References
- Chu, Y.; Chen, X.; Zhong, Y.; Xia, H. Seismic fragility analysis of the steel frame with new layered assembled joints. Structures 2023, 58, 105380. [Google Scholar] [CrossRef] [Scilit]
- Papargyriou, I.; Mojtabaei, S.M.; Hajirasouliha, I.; Becque, J.; Pilakoutas, K. Cold-formed steel beam-to-column bolted connections for seismic applications. Thin-Walled Struct. 2022, 172, 108876. [Google Scholar] [CrossRef] [Scilit]
- Miller, D.K. Lessons learned from the Northridge earthquake. Eng. Struct. 1998, 20, 249–260. [Google Scholar] [CrossRef] [Scilit]
- Derakhshan, H.; Shekastehband, B. Seismic performance of bolted T-stub beam-to-box column connection. Structures 2023, 56, 104873. [Google Scholar] [CrossRef] [Scilit]
- Wang, W.; Li, L.; Chen, D. Progressive collapse behaviour of endplate connections to cold-formed tubular column with novel slip-critical blind bolts. Thin-Walled Struct. 2018, 131, 404–416. [Google Scholar] [CrossRef] [Scilit]
- Chen, C.C.; Lin, C.C.; Tsai, C.L. Evaluation of reinforced connections between steel beams and box columns. Eng. Struct. 2004, 26, 1889–1904. [Google Scholar] [CrossRef] [Scilit]
- Ghobarah, A.; Mourad, S.; Korol, R.M. Moment-rotation relationship of blind bolted connections for HSS columns. J. Constr. Steel Res. 1996, 40, 63–91. [Google Scholar] [CrossRef] [Scilit]
- Elghazouli, A.Y.; Málaga-Chuquitaype, C.; Castro, J.M.; Orton, A.H. Experimental monotonic and cyclic behaviour of blind-bolted angle connections. Eng. Struct. 2009, 31, 2540–2553. [Google Scholar] [CrossRef] [Scilit]
- Wang, J.; Zhang, L.; Spencer, B.F. Seismic response of extended end plate joints to concrete-filled steel tubular columns. Eng. Struct. 2013, 49, 876–892. [Google Scholar] [CrossRef] [Scilit]
- Wang, J.; Chen, L. Experimental investigation of extended end plate joints to concrete-filled steel tubular columns. J. Constr. Steel Res. 2012, 79, 56–70. [Google Scholar] [CrossRef] [Scilit]
- Wang, W.; Li, L.; Chen, D.; Xu, T. Progressive collapse behaviour of extended endplate connection to square hollow column via blind Hollo-Bolts. Thin-Walled Struct. 2018, 131, 681–694. [Google Scholar] [CrossRef] [Scilit]
- Tizani, W.; Al-Mughairi, A.; Owen, J.S.; Pitrakkos, T. Rotational stiffness of a blind-bolted connection to concrete-filled tubes using modified Hollo-bolt. J. Constr. Steel Res. 2013, 80, 317–331. [Google Scholar] [CrossRef] [Scilit]
- Tizani, W.; Wang, Z.Y.; Hajirasouliha, I. Hysteretic performance of a new blind bolted connection to concrete filled columns under cyclic loading: An experimental investigation. Eng. Struct. 2013, 46, 535–546. [Google Scholar] [CrossRef] [Scilit]
- Pitrakkos, T.; Tizani, W. Experimental behaviour of a novel anchored blind-bolt in tension. Eng. Struct. 2013, 49, 905–909. [Google Scholar] [CrossRef] [Scilit]
- Pitrakkos, T.; Tizani, W.; Cabrera, M.; Salh, N.F. Blind bolts with headed anchors under combined tension and shear. J. Constr. Steel Res. 2021, 179, 106546. [Google Scholar] [CrossRef] [Scilit]
- Mahmood, M.; Tizani, W. A component model for column face in bending of extended HolloBolt connections. J. Constr. Steel Res. 2021, 182, 106655. [Google Scholar] [CrossRef] [Scilit]
- Cabrera, M.; Tizani, W.; Ninic, J.; Wang, F. Experimental and numerical analysis of preload in Extended Hollo-Bolt blind bolts. J. Constr. Steel Res. 2021, 186, 106885. [Google Scholar] [CrossRef] [Scilit]
- Thai, H.T.; Uy, B.; Yamesri; Aslani, F. Behaviour of bolted endplate composite joints to square and circular CFST columns. J. Constr. Steel Res. 2017, 131, 68–82. [Google Scholar] [CrossRef] [Scilit]
- Waqas, R.; Uy, B.; Thai, H.T. Experimental and numerical behaviour of blind bolted flush endplate composite connections. J. Constr. Steel Res. 2019, 153, 179–195. [Google Scholar] [CrossRef] [Scilit]
- Hosseini, S.M.; Mamun, M.S.; Mirza, O.; Mashiri, F. Behaviour of blind bolt shear connectors subjected to static and fatigue loading. Eng. Struct. 2020, 214, 110584. [Google Scholar] [CrossRef] [Scilit]
- Hosseini, S.M.; Mashiri, F.; Mirza, O. Research and developments on strength and durability prediction of composite beams utilising bolted shear connectors (Review). Eng. Fail. Anal. 2020, 117, 104790. [Google Scholar] [CrossRef] [Scilit]
- Wang, P.; Sun, L.; Zhang, B.; Yang, X.; Liu, F.; Han, Z. Experimental studies on T-stub to hollow section column connection bolted by T-head square-neck one-side bolts under tension. J. Constr. Steel Res. 2021, 178, 106493. [Google Scholar] [CrossRef] [Scilit]
- Sun, L.; Liang, Z.; Wu, L.; Li, C.; Liu, Y.; Liu, M.; Liu, F.; Wang, P. Experimental and theoretical modeling for predicting bending moment capacity of T-head square-neck one-side bolted endplate to tube column connection. J. Build. Eng. 2021, 43, 103104. [Google Scholar] [CrossRef] [Scilit]
- Sun, L.; Liang, Z.; Wang, Q.; Zhu, H.; Wang, P.; Liu, Y.; Liu, F. Seismic response on T-head square-neck one-side bolted endplate connection of beam to square tubular column. Eng. Struct. 2021, 246, 113077. [Google Scholar] [CrossRef] [Scilit]
- Sun, L.; Liang, Z.; Cai, M.; Liu, X.; Wang, P. Experimental investigation on monotonic bending behaviour of TSOBs bolted beam to hollow square section column connection with inner stiffener. J. Build. Eng. 2022, 46, 103765. [Google Scholar] [CrossRef] [Scilit]
- Sun, L.; Liang, Z.; Cai, M.; Liu, C.; Wang, P.; Liu, M.; Liu, F. Seismic behaviour of TSOBs bolted I-beam to hollow section square column connection with inner stiffener. J. Build. Eng. 2022, 51, 104260. [Google Scholar] [CrossRef] [Scilit]
- Hou, G.; Shang, Y.; Zhang, L.; Sun, L.; Wu, J.U.; Lu, Y.; Zhu, A.; Mou, Y. Bending performance of bolted beam-column joints with T-stubs. J. Constr. Steel Res. 2025, 226, 109280. [Google Scholar] [CrossRef] [Scilit]
- Özkılıç, Y.O.; Topkaya, C. The plastic and the ultimate resistance of four-bolt extended end-plate connections. J. Constr. Steel Res. 2021, 181, 106614. [Google Scholar] [CrossRef] [Scilit]
- Hou, G.; Kong, J.; Sun, L.; He, M.; Cheng, F.; Li, H.; Mou, Y. Ultimate strength determination of T-stub to hollow section column using TSOBs. J. Constr. Steel Res. 2025, 226, 109309. [Google Scholar] [CrossRef] [Scilit]
- EN 1993-1-8; Design of Steel Structures-Part1-8: Design of Joints. European Committer for Standardization. CEN: Brussel, Belgium, 2005.
- Lee, J.; Goldsworthy, H.M.; Gad, E.F. Blind bolted T-stub connections to unfilled hollow section columns in low rise structures. J. Constr. Steel Res. 2010, 66, 981–992. [Google Scholar] [CrossRef] [Scilit]
- Faella, C.; Piluso, V.; Rizzano, G. Structural Steel Semi-Rigid Connections: Theory, Design and Software; CRC Press: Boca Raton, FL, USA, 2000. [Google Scholar]
- Coelho, A.M.G.; Silva, L.S.D.; Bijlaard, F.S.K. Ductility analysis of bolted extended end plate beam-to-column connections in the framework of the component method. Steel Compos. Struct. 2006, 6, 33–53. [Google Scholar] [CrossRef] [Scilit]
- Abaqus-Inc. Abaqus User Manual, Version 2022 EF; Abaqus-Inc.: Palo Alto, CA, USA, 2022.
- GB 50017-2017; Code for Design of Steel Structure. China Architecture & Building Press: Beijing, China, 2017. (In Chinese)
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.