Review Reports
- Karel Saksl 1,2,*,
- Róbert Kočiško 1 and
- Adam Lupták 4
- et al.
Reviewer 1: Anonymous Reviewer 2: Eusebiu-Viorel Șindilar Reviewer 3: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsIn the manuscript, the authors investigated a Zn–0.1Mg alloy after processing using a two-stage equal channel angular pressing (ECAP) method. The authors carefully investigated the mechanical properties using uniaxial tensile tests at various strain rates, and also examined the microstructure and phase composition using synchrotron hard X-ray diffraction and transmission electron microscopy (TEM). The paper is well written and contains interesting results, on the basis of which significant conclusions are drawn. The manuscript will be of interest to researchers in the field of biodegradable materials.
I have the following comments on the manuscript:
- Materials and Methods. Mechanical Properties Analysis. “The tensile tests were carried out using an electromechanical testing machine H300KU Tinius Olsen (Tinius Olsen Testing Machine Company, 1065 Easton Road, Horsham, PA 19044, USA) at three different strain rates: 0.001 s⁻¹, 0.00025 s⁻¹, and 0.0001 s⁻¹.” It is unclear whether the test rate was constant during the tensile test. When the length of the sample increases, the traverse rate must be increased to maintain a constant deformation rate. Or is the initial rate indicated in this case? The authors must specify it.
- Figure 2. The labels on the x and y axes are completely invisible. Correction is required.
- Figure 3b. The red scale mark is completely invisible. Correction is required.
- Discussion. “The application of severe plastic deformation led to significant grain refinement from the initial size of >30 μm down to submicron dimensions.” Why don't the authors specify the final grain size here?
- Discussion. “…further hindered by fine Mg₂Zn₁₁ phase particles…”. How fine are the particles? Authors must specify the particle size.
- Discussion. “A further objective was to investigate whether this material could be brought into a superplastic state, i.e., achieving elongation ε > 200% at room temperature [45].” There is an error in source 45. This DOI has other authors, although the book title is correct.
- Discussion. “A further objective was to investigate whether this material could be brought into a superplastic state, i.e., achieving elongation ε > 200% at room temperature [45].” Why do authors use the value 200% as an indicator of the superplastic state? Typically, the rate sensitivity index m is also of great importance.
- Discussion. “This exceptional result indicates a high plastic reserve of the material, which can be further enhanced either by microalloying (e.g., with Li, Mn, Ca) or by additional plastic deformation.” I think that here the authors must explain the possible increase in plasticity due to microalloying with these elements.
Author Response
We would like to thank the reviewers for their thoughtful and constructive comments, which have helped us improve the clarity, rigor, and presentation of our manuscript.
Comment 1: Materials and Methods. Mechanical Properties Analysis. “The tensile tests were carried out using an electromechanical testing machine H300KU Tinius Olsen (Tinius Olsen Testing Machine Company, 1065 Easton Road, Horsham, PA 19044, USA) at three different strain rates: 0.001 s⁻¹, 0.00025 s⁻¹, and 0.0001 s⁻¹.” It is unclear whether the test rate was constant during the tensile test. When the length of the sample increases, the traverse rate must be increased to maintain a constant deformation rate. Or is the initial rate indicated in this case? The authors must specify it.
Response 1: Thank you for the remark. During each tensile test the crosshead (traverse) speed was kept constant; therefore, the values reported (0.001 s⁻¹, 0.00025 s⁻¹, 0.0001 s⁻¹) refer to the nominal initial engineering strain rates, computed from the crosshead speed and the initial gauge length. We have clarified this in the revised Methods section.
Comment 2: Figure 2. The labels on the x and y axes are completely invisible. Correction is required.
Response 2: The Figure 2 has been replaced with the updated version
Comment 3: Figure 3b. The red scale mark is completely invisible. Correction is required.
Response 3: The Figure 3 has been replaced with the updated version
Comment 4: 4. Discussion. “The application of severe plastic deformation led to significant grain refinement from the initial size of >30 μm down to submicron dimensions.” Why don't the authors specify the final grain size here?
Response 4: Thank you for pointing this out. We now report the final grain size explicitly.
Comment 5: 5. Discussion. “…further hindered by fine Mg₂Zn₁₁ phase particles…”. How fine are the particles? Authors must specify the particle size.
Response 5: Thank you for the suggestion. We have quantified the size of the Mg₂Zn₁₁ particles from TEM micrographs (Fig. 8d and Fig. 9d) using the equivalent circular diameter. The particles are nanometric: the number-weighted mean diameter is ~60 nm. These values have been added to the Discussion.
Comment 6: Discussion. “A further objective was to investigate whether this material could be brought into a superplastic state, i.e., achieving elongation ε > 200% at room temperature [45].” There is an error in source 45. This DOI has other authors, although the book title is correct.
Response 6: Thank you, we corrected the reference.
Comment 7: Discussion. “A further objective was to investigate whether this material could be brought into a superplastic state, i.e., achieving elongation ε > 200% at room temperature [45].” Why do authors use the value 200% as an indicator of the superplastic state? Typically, the rate sensitivity index m is also of great importance.
Response 7: Thank you for this important point. We used ε > 200% only as a pragmatic benchmark of very high ductility frequently employed in the superplasticity literature; however, we agree that elongation alone is not sufficient to establish a superplastic regime. Superplastic flow is typically associated with high strain-rate sensitivity (m ≳ 0.3–0.5) and grain-boundary-sliding; some authors also adopt a more stringent elongation threshold (ε ≥ 400%). We have rephrased the text to reflect this and now refer to “superplastic-like ductility” at room temperature unless m is quantified. Appropriate references have been added.
Comment 8: Discussion. “This exceptional result indicates a high plastic reserve of the material, which can be further enhanced either by microalloying (e.g., with Li, Mn, Ca) or by additional plastic deformation.” I think that here the authors must explain the possible increase in plasticity due to microalloying with these elements.
Response 8: Thank you for the suggestion. We now clarify how microalloying with Li, Mn and Ca can increase plasticity in Zn-based alloys.
(i) Li forms nanoscale LiZn₄ precipitates (≈10–30 nm) that refine/stabilize ultrafine grains and raise work-hardening; Li strongly strengthens Zn but may reduce ductility unless balanced by processing or by Mn additions.
(ii) Mn effectively increases elongation (up to ~84% reported in binary Zn–Mn) by grain refinement and activation of tensile twinning, which sustains strain hardening.
(iii) Ca additions can generate fine CaZn₁₃ dispersions that pin grain boundaries and stabilize ultrafine grains; when CaZn₁₃ is fine and well dispersed, significant ductility gains (≈49% EL) have been reported, whereas coarse particles are detrimental—hence the benefit is processing- and size-distribution-dependent.
We have added a concise, mechanism-based explanation and citations to the Discussion.
Reviewer 2 Report
Comments and Suggestions for AuthorsGeneral Feedback:
The overall structure and flow are strong.
Terminology is appropriate for the field.
Sentence structures are mostly clear and correct.
Your writing is scientifically rigorous, well-structured, and mostly free of major errors. The majority of issues are minor formatting or stylistic in nature, often due to line breaks.
With just a few edits, this text would be well-suited for publication in a scientific journal.
Comments for author File:
Comments.pdf
Your writing is scientifically rigorous, well-structured, and mostly free of major errors. The majority of issues are minor formatting or stylistic in nature, often due to line breaks.
With just a few edits, this text would be well-suited for publication in a scientific journal.
Author Response
We reply on all the comments in the attached file
Author Response File:
Author Response.pdf
Reviewer 3 Report
Comments and Suggestions for AuthorsThis study investigates Zn0.1Mg that was processed using a two-step ECAP route: a first pass at 150 °C, followed by a second pass at room temperature. Uniaxial tensile tests were performed at three strain rates. The microstructure and phase composition were analysed using synchrotron X-ray diffraction and TEM. ECAP processing was found to enhance strength and ductility, with up to 240% elongation observed at the lowest strain rate. The analysis revealed a supersaturated Zn matrix with a minor Mg₂Zn₁₁ phase, an ultrafine-grained microstructure, and activation of non-basal slip systems.
The paper presents interesting results based on high-quality methods. The research makes a valuable contribution to the field. The study is performed with confidence. The methodology is generally sound. However, the paper lacks structure in terms of choosing the right focus for the introduction and discussion based on the results obtained. The results, especially those concerning the microstructure/grain size, need to be clearer and presented based on statistical methods. Furthermore, to confirm the potential of Zn alloys for a new generation of biodegradable implants, more than just mechanical tests must be performed, such as degradation and biocompatibility tests. The lack of strain hardening is neither discussed critically nor mentioned. Also, please discuss the need for superplasticity in relation to the 15–18% you summarise as required.
Before publication, the paper needs to be improved. Please see the suggestions and recommendations, as well as the aspects of the discussion that are unclear.
Introduction
- introduction focuses too much on permanent, you could start straight away with biodegradable metals, there is no need to compare with permanent hip implants – this is not the product Zn alloys might replace
- table 1 needs references, either one, in case all data are from one source or more than one, when the table is based on many references
- you claim, table 1 shows that materials must not induce adverse local or systemic inflammation, gas bubble formation etc. Where do you see this?
- line 98-99: I am not so sure about Ca-based systems
- instead of focusing on permanent materials the Introduction should be extended on introducing to Zn-Mg based alloys and especially on extending introduction to superplasticity and severe plastic deformation
Materials and Methods
- for the ECAP deformation is the deformation speed missing
- (a) (b) (c) (d) is oversized in Figure 1, so Figure 2
- please add the number of tensile specimens per condition and deformation speed, this is important for the statistics
- please add to the figure caption of Figure 2 what there is shown: sample, diffraction pattern etc and it should be part of the results
- line 200: fundamental could be removed
- I guess, the underlined parts in lines 215 and 223-225 can be removed
- please add to Table 2 the standard deviation to all data
- highly recommended is to the light optical microstructure – it is of value to evaluate the TEM images, but the microstructure of lower magnification is important for the basic understanding
- Figure 4a and b: please add the meaning of the different colours and in Figure 4c the font size of the label needs to be higher, so for all the axis
- line 265: before with “3.3 Analysis of First-Order Elastic Residual Strains and Stresses” investigated residual strain and stress there is no introduction to this topic, no motivation, no literature
- line 306: please explain what is the difference between the substructure and the grain size? …how did you evaluate the average grain size? …an average value needs to have a standard deviation – only with this you can discuss the difference … how many grains have been measured?
Discussion
- the first paragraph (lines 344-359) is clearly part of the Introduction, please move it
- please check if the paragraph in lines 360-366 agrees with the motivation presented at the end of the Introduction
- please check line 370: why do you mention further enhancement by microalloying with Li, Mn and Ca?
- line 395/396: here you claim no significantly change in crystallite size, being ~ 1 µm – however, your discussion is based on grain refinement
- see lines 396 and 414: you should not discuss grain refinement in such an amount when you do not see it yourself, plus by not providing statistically verified measurements. What do you mean with grain size being comparable with crystallite size… you discuss grain refinement mainly on the basis of literature, not on your own results … since the studies from the literature are applying different process parameter and/or alloys, this is not really comparable
Conclusion
- the first part of the “conclusion” does not contain any of your results and findings and does not belong in a conclusion
- finding 1. when comparing to the annealed stage, it might be better to characterise it
- finding 4. In your discission you speak of a grain size not changing around 1 µm, here you say 0.5 to 1 µm, please revise – still nit sure if you mean no grain size change or refinement
- finding 6. Please be very carefully with saying that your results confirm the potential for a new generation of biodegradable implants – that needs the investigation of more aspects, especially biocompatibility
Author Response
We reply on all comments in the attached document
Author Response File:
Author Response.pdf
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThe authors corrected and significantly improved the manuscript. I think the manuscript can be accepted for publication.
Author Response
Comments 1: The authors corrected and significantly improved the manuscript. I think the manuscript can be accepted for publication.
Response 1: Thank you very much
Reviewer 3 Report
Comments and Suggestions for AuthorsStatistical data - individual standard deviation should be provided insteat of an overall percentage (<5%) value - mainly that made my decision to MAJOR
Author Response
Comments 1: Statistical data - individual standard deviation should be provided insteat of an overall percentage (<5%) value - mainly that made my decision to MAJOR
Response 1: Thank you. We have revised Table 2 to report individual standard deviations for each value (mean ± SD).