Skip to Content
DiagnosticsDiagnostics
  • Article
  • Open Access

24 November 2026

23 Pages

CBCT-Based Radiomics and Machine Learning Differentiation of Maxillary Sinus Mucous Retention Cyst, Radicular Cyst, and Periapical Cemento-Osseous Dysplasia

,
,
,
and
1
Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Harran University, Şanlıurfa 63300, Türkiye
2
Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Harran University, Şanlıurfa 63300, Türkiye
3
Yüreğir Karşıyaka Oral and Dental Health Hospital, Adana 01000, Türkiye
*
Author to whom correspondence should be addressed.

Abstract

Background/Objectives: This study evaluated the performance of machine learning algorithms based on radiomic features extracted from cone-beam computed tomography images for the three-class classification of maxillary sinus mucous retention cysts, radicular cysts, and periapical cemento-osseous dysplasia. Methods: This single-centre retrospective study included 119 lesions from 119 patients, comprising 41 mucous retention cysts, 39 radicular cysts, and 39 cases of periapical cemento-osseous dysplasia. Radicular cysts and mucous retention cysts were histopathologically confirmed; dysplasia labels were based on archived diagnoses. Following manual three-dimensional segmentation, 107 radiomic features were extracted, and eight machine learning algorithms were evaluated. The primary analysis was performed using repeated nested stratified cross-validation in a development cohort of 95 cases, whereas the secondary evaluation was conducted in a held-out internal test cohort of 24 cases. Results: The highest balanced accuracy in the development cohort was achieved by Support Vector Machine (0.910 ± 0.069), whereas Extra Trees achieved the highest macro-averaged one-vs-rest area under the receiver operating characteristic curve (0.983 ± 0.018). In the internal test cohort, Support Vector Machine, Light Gradient Boosting Machine, Random Forest, Extreme Gradient Boosting, and Gradient Boosting each correctly classified 23 of 24 cases, achieving accuracy and balanced accuracy of 0.958. Conclusions: Machine learning models based on cone-beam computed tomography radiomic features demonstrated high internal performance in differentiating the three lesion groups. These findings support proof-of-concept technical feasibility but do not establish a clinically viable classification framework. Superiority over experienced clinicians and incremental diagnostic value beyond conventional radiological assessment or established radiomic approaches were not evaluated and remain unestablished. Independent multicentre validation and comparative clinical evaluation are required before clinical implementation.

1. Introduction

Accurate identification of lesions in the maxillofacial region is important for treatment planning and follow-up. Maxillary sinus mucous retention cysts and periapical cemento-osseous dysplasia may be incidental radiographic findings [1,2]. The diagnostic assessment of these entities and radicular cysts requires consideration of anatomical location, radiographic appearance, and clinical context [1,2,3]. These entities do not constitute a uniform three-way differential diagnosis in routine practice.
Radicular cysts are common inflammatory periapical lesions [3,4]. Periapical radiography, panoramic imaging, and cross-sectional imaging are used to evaluate these lesions and their extent [3,4]. Their diagnosis is relevant to treatment planning, although lesion type alone does not determine management: nonsurgical endodontic treatment, decompression, or surgical management may be considered according to the clinical situation [3,4,5].
A maxillary sinus mucous retention cyst is a benign mucosal lesion that typically appears as a rounded, dome-shaped soft-tissue mass, commonly along the sinus floor. Such cysts are often detected incidentally on radiographic examinations [1].
Periapical cemento-osseous dysplasia can present as radiolucent lesions or lesions with central radiodensity; fibrous tissue and mineralised cemental material have been described histologically [6]. Clinical assessment, including pulp testing, is important when interpreting these appearances, because misdiagnosis may lead to unnecessary treatment [2].
A common feature of these lesions is the central role of radiological assessment in the diagnostic process. For periapical cemento-osseous dysplasia, integrating radiographic findings with clinical assessment helps avoid misdiagnosis and unnecessary treatment [2]. Radiomics has been investigated as a quantitative approach to characterising imaging features [7,8,9]; whether it provides additional diagnostic value beyond experienced visual interpretation requires direct comparative evaluation. The clinical considerations described above concern specific diagnostic contexts, such as assessment of a periapical lesion or clarification of the relationship of a lesion to the maxillary sinus; they do not imply that all three entities are routinely competing diagnoses in the same patient. Their inclusion in a single classification task provides an exploratory comparison across distinct lesion categories, rather than a direct simulation of a defined clinical diagnostic dilemma.
Radiomics is an image-analysis approach that enables the extraction of high-dimensional quantitative features from medical images, thereby transforming images into a source of candidate quantitative imaging biomarkers [9,10]. Radiomic analyses may include first-order intensity measures, shape descriptors, and texture features describing spatial grey-level relationships [11]. Previous studies have applied CBCT-based radiomics to the classification of odontogenic lesions [7,8]. The present study explores an application of established radiomic features and machine learning algorithms to three lesion groups; it does not introduce a new AI architecture, segmentation technology, or feature-extraction method, nor does it establish incremental diagnostic gain over a classical radiomics reference approach.
The primary aim of this single-centre retrospective pilot study was to evaluate the performance of eight machine learning algorithms based on radiomic features extracted from CBCT images in three-class classification of maxillary sinus mucous retention cysts, radicular cysts, and periapical cemento-osseous dysplasia using repeated nested stratified cross-validation. The secondary aims were to assess model performance in a held-out internal test cohort and to describe exploratory feature-importance rankings. The scope was an exploratory three-class comparison using established methods, rather than the development of a new AI technology. The rationale for this comparison was to examine radiomic separability across three biologically and anatomically distinct lesion categories. This design evaluates technical feasibility within a restricted set of labels; it does not establish that the three-class task is clinically necessary or that radiomics improves routine diagnosis.

2. Materials and Methods

2.1. Study Design and Ethical Approval

This retrospective, analytical, archive-based observational study was conducted using CBCT images obtained from the archives of the Department of Oral and Maxillofacial Radiology of the institution. The study protocol was approved by the Gaziantep University Non-Interventional Clinical Research Ethics Committee (Decision No. 2026/232; 6 May 2026), and the study was conducted in accordance with the principles of the Declaration of Helsinki. As the study used archived CBCT images that had previously been acquired for clinical indications, including the evaluation of cystic and other maxillofacial lesions, assessment of impacted teeth, surgical planning, and similar purposes, no additional imaging was performed for research purposes and patients were not exposed to any additional radiation. All data were anonymised before analysis, and personally identifiable information was removed from the research dataset.

2.2. Study Population and Sample

The study population comprised CBCT records available in the imaging archive of the Department of Oral and Maxillofacial Radiology of the institution. Cases were identified retrospectively using histopathological records for radicular cysts and maxillary sinus mucous retention cysts, and clinical and radiographic diagnostic records for periapical cemento-osseous dysplasia. Cases that did not meet the eligibility criteria were not included. The final study sample comprised 119 cases, including 41 mucous retention cysts, 39 radicular cysts, and 39 cases of periapical cemento-osseous dysplasia. Verified counts of the records initially screened and cases excluded for each reason were not available for reporting.
  • Inclusion criteria
Cases were included if they met the following criteria:
  • availability of CBCT images from individuals aged 6 years or older;
  • retrospective images available in the institutional archive and eligible for use within the scope of the ethics committee approval;
  • presence of a diagnostic label for mucous retention cyst, radicular cyst, or periapical cemento-osseous dysplasia in the archive records;
  • lesion boundaries sufficiently well defined on CBCT images;
  • adequate image quality to allow segmentation of a region of interest (ROI) or volume of interest (VOI) suitable for radiomic analysis;
  • images acquired using a standardised CBCT imaging protocol; and
  • absence of metal artefacts in the lesion region severe enough to interfere with evaluation.
  • Exclusion criteria
Cases were excluded if they met any of the following criteria:
  • lesions with an uncertain or inconclusive diagnosis, or the coexistence of multiple pathologies;
  • images unsuitable for ROI/VOI segmentation or in which lesion boundaries could not be delineated;
  • images with severe metal artefacts, motion artefacts, or technical deficiencies that could affect radiomic analysis;
  • cases with a history of previous surgical intervention in the region of interest or other procedures that could alter lesion morphology; or
  • individuals with a history of systemic disease or medication use that could substantially affect the structure of the jawbone or the relevant anatomical region.
Diagnostic classification and data recording
Following the archive review, eligible cases were classified into three groups:
  • mucous retention cyst,
  • radicular cyst, and
  • periapical cemento-osseous dysplasia.
Diagnostic classification was based on group-specific reference standards. For radicular cysts, the reference diagnosis was the diagnosis recorded in the lesion-specific histopathology report; confirmation was available for 39/39 cases (100%). For maxillary sinus mucous retention cysts, the reference diagnosis was likewise established from the lesion-specific histopathology report; confirmation was available for 41/41 cases (100%). For PCOD, published clinico-radiographic descriptions identify a lesion centred in the periapical, tooth-bearing region and associated with a vital tooth as key diagnostic considerations. PCOD is commonly asymptomatic, and its radiographic appearance may progress from radiolucent to mixed and then predominantly radiopaque as the lesion matures; clinical and radiographic correlation and follow-up help distinguish it from endodontic periapical disease [2]. In this retrospective study, no additional clinical examinations or pulp vitality tests were performed for research purposes. According to the archived clinical records, the tooth associated with each PCOD lesion had been assessed during routine care and recorded as vital. The archived records indicated that the PCOD diagnosis was based on clinical and radiographic assessment and that follow-up had been recommended. However, symptom status and each individual radiographic criterion were not documented in a standardised manner across all records, so their presence could not be independently verified for every case. Accordingly, PCOD labels reflect the original archived diagnoses and were not reassigned using a uniform, prospectively specified rule. None of the 39 PCOD cases had histopathological confirmation (0/39; 0%). Thus, 80/119 lesions (67.2%) were histopathologically confirmed, and 39/119 (32.8%) were classified using archived diagnoses without histopathological confirmation. The archived dysplasia diagnoses were used as the reference labels rather than diagnoses assigned by the segmentation observer or generated by the machine learning models. These record-based labels should not be interpreted as evidence that a uniform, prospectively specified clinical and radiographic diagnostic rule was applied across all dysplasia cases. The reference standard was therefore heterogeneous across the three diagnostic groups. Cases with uncertain or conflicting diagnoses or with the possibility of more than one pathology were excluded from the study.
Information on age, sex, lesion location, and diagnostic group available in the archive records was recorded; these variables were not included as predictors in the machine learning models.

2.3. CBCT Imaging Protocol

All CBCT images evaluated in this study were acquired using a Castellini X-Radius Trio Plus unit (Imola, Italy). Imaging was performed according to the manufacturer’s recommended standard acquisition protocol using 70 kVp, 10 mA, and an exposure time of 32 s. Images were reconstructed using IRYS 15.0 (Imola, Italy) software with a voxel size of 0.3 mm and evaluated in the axial, coronal, and sagittal planes. Image acquisition and device calibration were performed in accordance with the manufacturer’s standard protocols, and efforts were made to maintain imaging parameters as consistently as possible across cases.

2.4. Preparation of CBCT Images

CBCT data from cases meeting the inclusion criteria were exported from the archive in Digital Imaging and Communications in Medicine (DICOM) format. All images were acquired using the same CBCT unit and standard imaging protocol and reconstructed with an isotropic voxel size of 0.3 mm. Before radiomic analysis, all images were evaluated using the same workflow and included in the analysis while preserving the original imaging parameters.

2.5. Lesion Segmentation

All segmentation procedures were performed using the open-source 3D Slicer software (version 5.11.0; Brigham and Women’s Hospital, Boston, MA, USA). Each lesion was segmented three-dimensionally by simultaneously evaluating the axial, coronal, and sagittal planes. An ROI/VOI encompassing the entire lesion volume was created for each lesion.
Lesion boundaries were delineated using manual slice-by-slice segmentation with simultaneous evaluation of the axial, coronal, and sagittal planes. Segmentation was performed according to the visible lesion boundaries on CBCT images without disclosure of the diagnostic labels to the observer. For each case, a three-dimensional ROI/VOI encompassing the entire volume of the identified lesion was created. Surrounding anatomical structures not belonging to the lesion and areas containing prominent artefacts were excluded from the ROI/VOI. The same segmentation approach was applied to mucous retention cysts, radicular cysts, and periapical cemento-osseous dysplasia, with the entire lesion volume segmented along the visible boundaries of the predefined lesion. The overall workflow was therefore semi-automated: manual lesion delineation preceded computational radiomic feature extraction and machine learning classification.
All segmentations were performed by a single oral and maxillofacial radiologist with two years of experience in dentomaxillofacial radiology, following a standardised segmentation protocol. The observer was blinded to the diagnostic labels during segmentation; anatomical location and lesion appearance remained visible on the CBCT images. Each case was segmented once by a single radiologist. No repeat segmentation by the same observer or independent segmentation by a second observer was performed; therefore, intraobserver and interobserver reproducibility could not be assessed. No dedicated analysis of radiomic feature stability under segmentation variation or changes in CBCT acquisition or reconstruction parameters was conducted.
Representative examples of manual three-dimensional segmentation are shown in Figure 1 for periapical cemento-osseous dysplasia, Figure 2 for radicular cyst, and Figure 3 for mucous retention cyst.
Figure 1. Representative CBCT images of the manual three-dimensional segmentation of periapical cemento-osseous dysplasia before radiomics analysis.
Figure 2. Representative CBCT images of the manual three-dimensional segmentation of a radicular cyst before radiomics analysis.
Figure 3. Representative CBCT images of the manual three-dimensional segmentation of a mucous retention cyst before radiomics analysis.

2.6. Image Preprocessing

All CBCT images were acquired using the same device and standard imaging protocol and reconstructed with an isotropic voxel size of 0.3 mm. No additional voxel resampling, Laplacian of Gaussian filtering, or wavelet transformation was applied during radiomic analysis. Only the original images were analysed. A fixed bin width of 25 was used for grey-level discretisation, and the symmetric grey-level co-occurrence matrix (GLCM) option was used for GLCM calculations. These parameters were applied consistently across all cases.
Radiomic feature extraction:
Following completion of the segmentation procedures, radiomic features were automatically extracted using the Radiomics module in 3D Slicer (version 5.11.0). The following feature classes were evaluated for each lesion:
  • First-order histogram features: grey-level statistics including intensity distribution, mean, median, entropy, energy, and uniformity;
  • Shape features: morphological parameters including volume, surface area, sphericity, elongation, and flatness;
  • Grey-level co-occurrence matrix (GLCM) features;
  • Grey-level run-length matrix (GLRLM) features;
  • Grey-level size-zone matrix (GLSZM) features;
  • Neighbouring grey-tone difference matrix (NGTDM) features; and
  • Grey-level dependence matrix (GLDM) features.
A total of 107 radiomic features extracted exclusively from the original images were included in the analysis. No features were extracted from filtered or transformed images. The resulting radiomic data were transferred to an electronic database and prepared for statistical analysis.

2.7. Primary Study Endpoint

The primary endpoint of the study was balanced accuracy calculated using repeated nested stratified cross-validation within the development cohort. Secondary endpoints included accuracy, macro F1-score, Matthews correlation coefficient (MCC), Cohen’s κ, and macro-averaged one-vs-rest (OvR) receiver operating characteristic area under the curve (ROC-AUC), as well as performance in the held-out internal test cohort and exploratory model-based feature-importance rankings.

2.8. Machine Learning-Based Classification Analysis

All radiomic features obtained in the study were combined into a single electronic database, and machine learning analyses were performed using the Python (version 3.13.16) programming language (Python Software Foundation, Wilmington, DE, USA). The scikit-learn (version 1.6.1), XGBoost (version 3.4.1), and LightGBM (version 4.6.0) libraries were used for the analyses. The data were initially assessed for missing values; when missing observations were present, median imputation was applied. All radiomic features were subsequently standardised using StandardScaler to prevent differences in feature scales from affecting model performance. Imputation and standardisation were incorporated into a scikit-learn pipeline to ensure that preprocessing parameters were determined exclusively from the corresponding training data within each cross-validation training fold. No feature selection or dimensionality reduction was performed in the primary analysis; all 107 radiomic features were retained. Correlation-based feature filtering was evaluated separately as a sensitivity analysis. In that analysis, the filter was incorporated into the modelling pipeline and fitted exclusively on the corresponding training partition, including each inner training fold during hyperparameter optimisation. Non-varying features were removed, and features were retained in input-column order only when their absolute Spearman correlation with every previously retained feature was below 0.90. The fitted transformation was then applied to the corresponding validation partition without re-estimating the correlations or feature subset. The held-out test cohort was not used to determine which features were retained. Accordingly, the analyses were considered exploratory model development.
The dataset was stratified to preserve class distributions and divided into an 80% development cohort and a 20% held-out test cohort. The development cohort comprised 95 cases, whereas the held-out test cohort comprised 24 cases. The three-class classification problem included the mucous retention cyst, radicular cyst, and periapical cemento-osseous dysplasia groups. The held-out test cohort was not used for model development, hyperparameter optimisation, cross-validation, generation of learning curves, or feature-importance analysis and was used only for final internal evaluation after completion of all model-development procedures.
Random Forest, Extra Trees, Support Vector Machine (SVM), XGBoost, Gradient Boosting, Logistic Regression, K-Nearest Neighbours (KNN), and LightGBM algorithms were evaluated for classification. To reduce variability in model performance attributable to sample splitting and to limit optimism bias associated with hyperparameter optimisation, the primary performance analysis was conducted exclusively within the development cohort using repeated nested stratified cross-validation. In the outer cross-validation loop, five-fold stratified cross-validation was repeated 10 times, yielding a total of 50 outer validation folds for each model. Within each outer training fold, optimal hyperparameters were independently determined using five-fold stratified GridSearchCV. The prespecified primary performance metric for hyperparameter optimisation was balanced accuracy.
These algorithms were selected to represent regularised linear classification (Logistic Regression), nonlinear kernel classification (SVM), distance-based classification (KNN), randomised tree ensembles (Random Forest and Extra Trees), and boosting approaches (Gradient Boosting, XGBoost, and LightGBM).

2.9. Model Performance Evaluation

In the primary performance evaluation, accuracy, balanced accuracy, macro F1-score, MCC, Cohen’s κ, and macro-averaged OvR ROC-AUC were calculated. Performance values obtained across the outer validation folds were reported as mean ± standard deviation (Table 1). The standard deviation describes variability across outer validation folds and is not a confidence interval for performance in the target population. The distribution of balanced accuracy values across the outer validation folds was additionally presented using boxplots (Figure 4), and comparative results of the models across all primary performance metrics were visualised using a heatmap (Figure 5).
Table 1. Repeated nested stratified cross-validation performance in the development cohort (n = 95). Values are mean ± standard deviation across 50 outer validation folds (five folds repeated 10 times).
Figure 4. Distribution of balanced accuracy across 50 outer validation folds obtained using repeated nested stratified five-fold cross-validation with 10 repetitions in the development cohort (n = 95). The dashed horizontal line represents the chance-level balanced accuracy for the three-class classification task (0.33).
Figure 5. Heatmap of mean classification performance metrics obtained across 50 outer validation folds of the repeated nested cross-validation analysis in the development cohort (n = 95). Values represent the mean accuracy, balanced accuracy, macro F1-score, Matthews correlation coefficient, Cohen’s κ, and macro-average One-vs-Rest ROC-AUC for each model. The displayed means correspond to Table 1; fold-to-fold standard deviations are reported in that table.
After completion of the nested cross-validation analysis, the final hyperparameters for each algorithm were determined using five-fold GridSearchCV on the entire development cohort (Table 2). The final models were trained on all 95 cases in the development cohort and evaluated once on the held-out test cohort of 24 cases, which had not been used at any stage of model development.
Table 2. Final model hyperparameters selected by five-fold GridSearchCV on the full development cohort (n = 95), using balanced accuracy as the optimisation metric.
Performance in the held-out test cohort was evaluated using accuracy, balanced accuracy, macro F1-score, MCC, Cohen’s κ, and macro-averaged OvR ROC-AUC. To estimate uncertainty around these performance metrics, a stratified percentile bootstrap analysis with 2000 resamples, preserving the class distribution, was performed, and 95% confidence intervals were calculated (Table 3). Bootstrap intervals were calculated from fixed test predictions without model refitting. Perfect separation in the observed test sample can yield an AUC interval of 1.000–1.000 when the same observations are resampled; this does not indicate certainty of perfect performance in new patients.
Table 3. Performance in the held-out internal test cohort (n = 24; eight cases per diagnostic group). Values are point estimates with 95% stratified percentile bootstrap confidence intervals (2000 resamples).
Multiclass ROC analyses were performed using the OvR approach, and class-specific ROC curves for each diagnostic group, together with macro-averaged ROC curves, were generated (Figure 6). Confusion matrices based on case counts were also generated (Figure 7). Learning curves were constructed using only the development cohort for the three models with the highest balanced accuracy in the primary nested cross-validation analysis (Figure 8).
Figure 6. One-vs-rest (OvR) receiver operating characteristic (ROC) curves for the eight models in the held-out internal test cohort (n = 24; eight cases per group). From left to right, panels show Group 1 (mucous retention cyst), Group 2 (radicular cyst), Group 3 (periapical cemento-osseous dysplasia), and the macro-average. The horizontal axis is the false-positive rate (1-specificity), and the vertical axis is the true-positive rate (sensitivity). Legends report AUC values; macro-averaged values correspond to Table 3. The dashed diagonal indicates chance discrimination.
Figure 7. Confusion matrices for the eight models in the held-out internal test cohort (n = 24; eight cases per group). Rows indicate reference-standard classes and columns indicate predicted classes; cell values are raw case counts. Group 1: mucous retention cyst; Group 2: radicular cyst; Group 3: periapical cemento-osseous dysplasia. Panel headings show accuracy (Acc) and macro-averaged OvR AUC, as reported in Table 3. AUC values derive from prediction scores rather than the displayed class counts.
Figure 8. Learning curves of the three models with the highest mean balanced accuracy in the primary nested cross-validation analysis: Support Vector Machine, Extra Trees, and Gradient Boosting. Training and cross-validation balanced accuracy are shown according to increasing training-set size using the development cohort only. Blue circles indicate training scores and orange squares indicate cross-validation scores. These development-cohort curves are distinct from the held-out test results.

2.10. Feature Importance Analysis

For the feature importance analysis, model-based importance scores from the Random Forest, Extra Trees, XGBoost, Gradient Boosting, and LightGBM algorithms were used. Importance values from each model were normalised within that model, and the mean normalised importance score across models was calculated for each feature. The 20 features with the highest mean importance scores are presented in Figure 9. This approach was used to generate a common exploratory ranking across model families; the importance scores were not interpreted as indicating the direction of effect, class-specific differences, independent diagnostic biomarkers, or causal relationships. Averaging normalised importance scores across algorithms was a descriptive aggregation and was not a test of sampling stability or statistical significance.
Figure 9. Top 20 radiomic features ranked according to mean normalised model-based feature importance (%) across Random Forest, Extra Trees, XGBoost, Gradient Boosting, and LightGBM models. Error bars represent the standard deviation of normalised importance scores across models, not variability across sampling iterations or cross-validation folds; they do not establish ranking stability or statistical significance. Feature-importance analysis was performed using the development cohort only.

2.11. Feature-Set and Stability Analyses

SVM, Extra Trees, and Logistic Regression were compared using shape-only (14 features), first-order-only (18), texture-only (75), combined (107), volume-only (MeshVolume), and shape-plus-first-order (32) inputs. SVM and Extra Trees represented the leading primary models for balanced accuracy and AUC, respectively, and Logistic Regression provided a regularised linear comparator. Each configuration used the same 50 outer development folds and five-fold inner hyperparameter optimisation, with imputation and standardisation fitted within the pipeline. The test cohort was excluded from these comparisons. Performance was summarised as mean ± standard deviation across outer folds.
A seventh configuration applied correlation filtering to the combined features. Within each pipeline training subset, including inner training folds, non-varying features were removed and features were retained in input-column order only if their absolute Spearman correlation with all previously retained features was below 0.90. Development-cohort correlations were summarised separately for descriptive purposes.
For the combined SVM and Extra Trees models, permutation importance was measured on each outer validation fold as the decrease in balanced accuracy over 10 permutations per feature. Ranking stability was summarised using pairwise Spearman correlation and Jaccard overlap of positive-importance sets with average rank ≤ 10; undefined comparisons were omitted. These are descriptive measures because validation folds overlap. Test predictions were also inspected at the individual-case level.

3. Results

A total of 119 cases were included in the final analysis. Of these, 41 were classified as mucous retention cysts, 39 as radicular cysts, and 39 as periapical cemento-osseous dysplasia. A total of 107 radiomic features were extracted from each case, and no missing feature values were identified in the dataset. Following stratified data splitting, 95 cases were allocated to the development cohort and 24 to the held-out test cohort. The held-out test cohort included eight cases from each diagnostic group.

3.1. Repeated Nested Cross-Validation Results

In the 10-times repeated five-fold nested stratified cross-validation analysis performed on the development cohort, the SVM model achieved the highest mean performance for balanced accuracy, the prespecified primary performance metric. The mean accuracy of the SVM was 0.908 ± 0.070, balanced accuracy was 0.910 ± 0.069, macro F1-score was 0.908 ± 0.070, MCC was 0.869 ± 0.099, and Cohen’s κ was 0.862 ± 0.104. The macro-averaged OvR AUC for the SVM was 0.975 ± 0.026 (Table 1).
In terms of balanced accuracy, the SVM was followed by Extra Trees (0.908 ± 0.064), Gradient Boosting (0.907 ± 0.066), Random Forest (0.905 ± 0.069), and XGBoost (0.903 ± 0.057). Balanced accuracy values for Logistic Regression, LightGBM, and KNN were 0.889 ± 0.071, 0.887 ± 0.064, and 0.880 ± 0.064, respectively (Table 1; Figure 4).
For macro-averaged OvR AUC, the highest mean value was achieved by Extra Trees (0.983 ± 0.018). Random Forest achieved an AUC of 0.982 ± 0.022, followed by SVM (0.975 ± 0.026), Logistic Regression (0.973 ± 0.025), Gradient Boosting (0.971 ± 0.032), XGBoost (0.967 ± 0.033), LightGBM (0.966 ± 0.032), and KNN (0.953 ± 0.039) (Table 1; Figure 5). Thus, the SVM achieved the highest mean performance according to balanced accuracy, the prespecified primary performance metric, whereas Extra Trees achieved the highest mean ROC-AUC.
The distribution of nested cross-validation results showed that all models performed substantially above the chance-level balanced accuracy of 0.33 for the three-class classification problem (Figure 4). When the overall performance profiles of the models were considered, SVM, Extra Trees, Gradient Boosting, and Random Forest generally demonstrated high and comparable classification performance within the development cohort (Figure 5).

3.2. Hyperparameter Optimisation and Learning Curves

Following completion of nested cross-validation, the optimal hyperparameters for each model were determined using the final GridSearchCV performed on the entire development cohort (Table 2). SVM, Extra Trees, and Gradient Boosting, which achieved the highest balanced accuracy values in the primary nested cross-validation analysis, were included in the learning-curve analysis (Figure 8).
The learning curves showed that cross-validation scores generally remained high as the training sample size increased, while the gap between training and validation performance tended to decrease. However, given the limited sample size, these curves were not interpreted as direct evidence of future performance improvement or generalisability.

3.3. Held-Out Test Cohort Performance

After completion of all model-development and hyperparameter-optimisation procedures, the final models were evaluated on the held-out test cohort of 24 cases. SVM, LightGBM, Random Forest, XGBoost, and Gradient Boosting each correctly classified 23 of the 24 cases, achieving an accuracy of 0.958 and a balanced accuracy of 0.958. For these models, the macro F1-score was 0.958, MCC was 0.940, and Cohen’s κ was 0.938 (Table 3).
In the stratified bootstrap analysis, the 95% confidence intervals (CIs) for accuracy and balanced accuracy for these models were 0.875–1.000, while the 95% CIs were 0.870–1.000 for the macro F1-score, 0.832–1.000 for MCC, and 0.812–1.000 for Cohen’s κ (Table 3).
SVM and LightGBM achieved a macro-averaged OvR AUC of 1.000 in the held-out test cohort. The AUC was 0.999 for Random Forest (95% CI: 0.992–1.000), 0.997 for Logistic Regression (95% CI: 0.984–1.000), 0.992 for XGBoost (95% CI: 0.964–1.000), 0.991 for Extra Trees (95% CI: 0.961–1.000), 0.990 for Gradient Boosting (95% CI: 0.953–1.000), and 0.983 for KNN (95% CI: 0.948–1.000) (Table 3; Figure 6).
In the held-out test cohort, Logistic Regression achieved an accuracy of 0.917, balanced accuracy of 0.917, macro F1-score of 0.915, MCC of 0.884, and Cohen’s κ of 0.875. For KNN, accuracy, balanced accuracy, and macro F1-score were all 0.917, while MCC and Cohen’s κ were both 0.875. Extra Trees showed lower classification performance in the held-out cohort than the other models, with an accuracy of 0.875, balanced accuracy of 0.875, macro F1-score of 0.875, MCC of 0.815, and Cohen’s κ of 0.812 (Table 3).
Confusion matrix analysis showed that SVM, Random Forest, XGBoost, Gradient Boosting, and LightGBM correctly classified 23 of the 24 cases. Each of these five models made one Group 1-to-Group 3 error. SVM and Random Forest misclassified the same case, whereas XGBoost, Gradient Boosting, and LightGBM misclassified a different case. Two cases were misclassified by Logistic Regression and KNN, whereas three cases were misclassified by Extra Trees. None of the models misclassified any Group 2 cases (Figure 7). The ROC analyses also supported the high discriminative performance of the models in the held-out test cohort (Figure 6). However, given the limited sample size of the held-out test cohort, these findings were considered secondary internal test results rather than independent confirmation of the primary nested cross-validation findings.

3.4. Radiomic Feature Importance Analysis

The 20 radiomic features with the highest mean importance scores were identified by combining normalised model-based importance values derived from the tree-based algorithms (Figure 9). First-order intensity features, texture features derived from GLCM, GLDM, GLRLM, and NGTDM, and the shape feature SurfaceVolumeRatio were represented among the highest-ranked features. Because this ranking did not indicate the direction of effect or identify the diagnostic group in which individual feature values were higher, the findings were interpreted solely as exploratory and hypothesis-generating. Highly ranked features were not interpreted as statistically significant or independently informative biomarkers.

3.5. Feature-Set and Stability Results

Feature-set comparisons are presented in Table 4 and Table 5. Balanced accuracy ranged from 0.619 to 0.653 for volume-only models and from 0.727 to 0.763 for shape-only models. First-order-only models achieved 0.904 ± 0.072 for SVM, 0.911 ± 0.060 for Extra Trees, and 0.889 ± 0.060 for Logistic Regression; the corresponding combined-feature values were 0.910 ± 0.069, 0.908 ± 0.064, and 0.889 ± 0.071. Adding texture to shape-plus-first-order inputs changed mean balanced accuracy by +0.009, +0.003, and −0.009, respectively.
Table 4. Balanced accuracy in feature-set comparisons.
Table 5. Macro-averaged one-vs-rest AUC in feature-set comparisons.
The development cohort contained 411 feature pairs with absolute Spearman correlation ≥ 0.90. Correlation filtering retained 35–40 features in the outer-training refits and yielded balanced accuracies of 0.886 ± 0.071 for SVM, 0.907 ± 0.057 for Extra Trees, and 0.903 ± 0.074 for Logistic Regression. Mean pairwise importance-rank correlations were 0.031 for SVM and 0.038 for Extra Trees; mean positive top-10 Jaccard overlaps were 0.068 and 0.045, respectively (Table 6).
Table 6. Cross-fold stability of permutation importance in combined-feature models.

4. Discussion

In this single-centre retrospective pilot study, the performance of eight machine learning algorithms based on 107 radiomic features extracted from CBCT images was evaluated for the three-class classification of maxillary sinus mucous retention cysts, radicular cysts, and periapical cemento-osseous dysplasia. In the repeated nested stratified cross-validation analysis, SVM achieved the numerically highest balanced accuracy; however, the performances of the leading models were comparable. High-performance values were also obtained in the held-out internal test cohort of 24 cases from the same institution. Nevertheless, given the absence of demonstrated statistical superiority among the models, the small test sample, and the lack of external validation, these results should not be interpreted as evidence of clinical validity, but rather as exploratory internal-validation findings supporting technical feasibility. The potential contribution is limited to the exploratory comparison of these lesion groups within a single dataset; evaluating eight existing algorithms does not itself constitute methodological innovation. The practical relevance of this comparison remains unestablished in the absence of clinical benchmarks.
Previous studies have investigated CT- and CBCT-based quantitative image analysis for differentiating odontogenic and periapical lesions [3,7,8,12]. İçöz et al. evaluated 161 histopathologically confirmed odontogenic cysts; sphericity and GLSZM large area emphasis differed across all pairwise comparisons [7]. Sha et al. reported a test accuracy of 0.711 and class-specific AUCs of 0.781–0.849 for their three-class CBCT model [8]. Using multi-slice CT, Yomtako et al. reported AUCs of 0.727 for SVM and 0.701 for a decision tree in a chronologically separated, same-institution validation cohort [3]. In a CBCT study, Çetin et al. reported 90% accuracy for RadC-CNN [12]. These values describe different study designs and evaluation settings. The higher values observed in the present study should not be interpreted as evidence of algorithmic superiority, as differences in diagnostic groups, reference standards, imaging protocols, feature-selection procedures, and validation designs limit direct comparisons of model performance.
Duyan Yüksel et al. compared 101 histopathologically confirmed nasopalatine duct cysts with 101 age- and sex-matched normal nasopalatine ducts. Using 11 selected features, SVM achieved a test AUC of 1.00, with the other reported test metrics also equal to 1.00 [13]. Their matched binary comparison of a normal structure with a cyst differs from the present three-class lesion comparison. These results should therefore be interpreted within their respective diagnostic tasks and validation designs; neither a high reported value nor a difference between studies establishes performance in routine clinical practice.
The three diagnostic groups differ in anatomical location, tissue composition, and radiographic appearance. These differences may contribute substantially to their separability using radiomic features. Although anatomical location was not included as an explicit predictor, the extracted features may indirectly capture location-associated characteristics. Restricting feature extraction to the segmented lesion does not establish independence from anatomical context, because lesion shape, size, and internal intensity or texture patterns may covary with the anatomical compartment. The models may therefore distinguish broad anatomical and morphological patterns rather than features specific to the underlying pathological process. The models were not evaluated after adjustment for anatomical location, lesion volume, or other potentially relevant covariates. The relative contributions of anatomical location, general morphology, and pathology cannot be disentangled by the present analysis. The observed performance therefore cannot be interpreted as evidence of lesion-specific biological signatures independent of these factors. Rather, the findings demonstrate exploratory discrimination among the three lesion groups within the present dataset. Studies involving clinically competing diagnoses in comparable anatomical settings, with explicit assessment of size and morphological effects, are needed to establish whether radiomics provides additional diagnostic information. Group-specific age and sex distributions and detailed lesion-location frequencies are not presented. Their absence limits assessment of baseline comparability between the diagnostic groups and of the representativeness of the study population. Potential demographic differences and their contribution to the observed classification performance cannot therefore be assessed from the reported results. Excluding age, sex, and location from the model inputs does not establish that their potential influence is absent.
In the exploratory feature importance analysis, the presence of first-order intensity features together with GLCM-, GLDM-, GLRLM-, and NGTDM-based texture features among the highest-ranked features suggested that the models utilised information from multiple feature families. However, model-based importance values do not indicate the direction of effect, class-specific distributions, independent contributions, or statistical significance. In addition, the cross-fold stability of individual importance rankings was low (Table 6), which further supports cautious interpretation. Consequently, the ranking may depend on the sampled patients and the allocation of importance among correlated predictors. Averaging scores across algorithms does not establish sampling stability, and the between-model standard deviations in Figure 9 should not be interpreted as uncertainty estimates from repeated sampling. The findings of Lozano González et al., showing that parameters such as energy and NGTDM contrast were associated with lesion volume and erosion, support the possibility that these features may also be influenced by morphological characteristics [11]. Similarly, the importance of the SurfaceVolumeRatio feature may reflect differences in anatomical shape in addition to pathology. In addition, the cross-fold stability of individual importance rankings was low (Table 6), which further supports cautious interpretation. Therefore, the feature ranking should not be interpreted as a direct biological explanation but rather as a hypothesis-generating finding requiring validation in independent datasets. Feature-importance rankings cannot substitute for these comparisons or identify independent, validated biomarkers.
First-order-only models performed similarly to combined-feature models, whereas volume-only and shape-only models achieved lower balanced accuracy. The descriptive comparisons did not show a consistent incremental benefit from texture features across the three models. Limited stability of individual importance rankings and substantial feature correlation support cautious interpretation of individual feature contributions.
The finding that SVM achieved the highest balanced accuracy, whereas Extra Trees achieved the highest AUC in nested cross-validation, demonstrates that model rankings may vary with the performance metric. The differences between the leading models were small, and definitive superiority of any single model should not be claimed. Repeated nested cross-validation does not increase the number of independent patients or eliminate uncertainty arising from the limited sample. In the internal test cohort, 95.8% accuracy represented 23 correctly classified cases out of 24; one additional misclassification would reduce accuracy to 91.7%. With only eight cases per class, one misclassification changes class-specific sensitivity by 12.5 percentage points. Consequently, the test estimates are sensitive to the composition of this small cohort and may change substantially in another sample. The 24 test cases provide limited representation of the variability encountered in clinical practice. Repeated resampling of these cases does not supply additional independent test observations. These findings should therefore be regarded as exploratory internal performance estimates, not as evidence of established clinical diagnostic accuracy, and require confirmation in larger, independent cohorts.
Although SVM and LightGBM achieved a macro-averaged OvR AUC of 1.000 in the internal test cohort, each model misclassified one of the 24 cases. AUC measures discrimination based on prediction-score rankings rather than correctness of every assigned class label. The bootstrap confidence intervals of 1.000–1.000 should not be interpreted as certainty about performance in new patients. Resampling a small cohort with perfect observed separation may yield degenerate intervals that inadequately represent uncertainty beyond that sample. These results do not establish flawless diagnostic performance.
Several algorithms yielded identical aggregate classification metrics in the 24-patient internal test cohort. Such metrics have limited resolution in a small sample, and identical accuracy or confusion-matrix counts do not establish identical patient-level predictions or decision boundaries. AUC values differed among these models, indicating that their ranking performance was not uniformly identical. SVM and Random Forest misclassified the same case, whereas XGBoost, Gradient Boosting, and LightGBM misclassified a different case. Each model made one Group 1-to-Group 3 error, which explains the identical aggregate confusion matrices. Agreement across algorithms should not be interpreted as independent confirmation of robustness, because all models were developed and evaluated using the same patients, reference labels, and predictor set.
The strengths of this study include the fact that the 119 cases were obtained from 119 distinct patients, data splitting was performed at the patient level, preprocessing steps within the pipeline were learned exclusively from the training data, and hyperparameter optimisation was performed within independent inner folds of the nested cross-validation procedure. The exclusion of the held-out cohort from model development, hyperparameter selection, and feature importance analysis also ensured separation of the evaluation data from the model-development process. Nevertheless, the held-out cohort was derived from the same institution and archive, and all images were acquired using the same CBCT imaging system under consistent settings. It therefore constitutes internal held-out validation, not independent external validation. Neither this evaluation nor nested cross-validation establishes generalisability to patients from other institutions or to different imaging systems and acquisition protocols. The absence of a complete numerical account of screening and exclusions limits transparency of the case-selection process and assessment of potential selection bias. Restricting inclusion to cases meeting the diagnostic and imaging eligibility criteria may have favoured more readily classifiable lesions, potentially limiting the applicability of the reported performance to routine clinical populations.
The reference standard differed across diagnostic groups. All radicular cysts and maxillary sinus mucous retention cysts were histopathologically confirmed, whereas periapical cemento-osseous dysplasia was classified using archived diagnostic records without histopathological confirmation. Misclassification of the archived dysplasia diagnoses cannot be excluded, and its frequency and effect on model performance could not be quantified from the available reference-standard information. Incorrect reference labels could affect both model training and performance evaluation; the direction and magnitude of any resulting bias remain uncertain. Concern about reliance on image-based diagnostic labels therefore applies primarily to the dysplasia group rather than to the entire cohort. To the extent that CBCT findings informed the archived dysplasia diagnoses, classification performance may partly reflect agreement with the original radiographic interpretation rather than accuracy against an independent reference standard. Patient-level separation of the development and test cohorts does not eliminate this potential dependence. This heterogeneity in diagnostic verification should be considered when interpreting overall three-class performance.
The use of 107 radiomic predictors in 95 development patients raises concerns about model complexity, overfitting, and feature redundancy. The relevance of evaluating modelling choices is illustrated by Parmar et al., who compared the performance and stability of feature-selection and classification methods in CT radiomics [14]. Within cross-validation, each model was fitted on a subset of these 95 patients, further limiting the number of observations available for fitting relative to the predictor count. All 107 radiomic features were used in the primary models. Correlation filtering was assessed separately as a sensitivity analysis. Stability across alternative preprocessing settings was not evaluated. Training-partition preprocessing and nested hyperparameter optimisation limit information leakage and tuning-related optimism, but do not establish the absence of overfitting or eliminate uncertainty associated with the limited sample and high-dimensional predictor set. The 24-case internal test cohort provides only limited evidence about performance beyond the development data and cannot establish generalisability to other clinical populations. Neither nested cross-validation nor this internal evaluation controls for anatomical or volumetric differences between diagnostic groups. The reported performance should therefore be interpreted as exploratory and requires confirmation in larger, independent, multicentre cohorts.
Segmentation was performed by a single radiologist with two years of experience who was blinded to the diagnostic labels. Blinding did not conceal anatomical location or lesion appearance and does not establish reproducibility. Neither intraobserver nor interobserver reproducibility was assessed; consequently, the sensitivity of the extracted features and model predictions to segmentation variability remains unknown. Differences in boundary placement by another observer, or by the same observer on repeat segmentation, could alter the included voxels and consequently the shape, intensity, and texture features used by the classifiers. Such changes could affect feature-importance rankings and individual predictions, but their magnitude and direction were not quantified. Using one observer throughout the dataset may also introduce a consistent observer-specific segmentation pattern that internal validation does not test across observers. Therefore, the reported performance should be interpreted within the segmentation conditions evaluated in this study and cannot be assumed to persist with repeated or independently performed segmentation. Future studies should obtain independent segmentations from multiple observers and repeated segmentations from the same observer. They should assess agreement between lesion contours and separately evaluate the stability of extracted radiomic features and classification results under these segmentation variations. Agreement between contours alone would not establish that the resulting features and model predictions are reproducible.
The use of a single CBCT unit and a consistent acquisition protocol limited technical heterogeneity within the dataset but did not establish robustness across devices, acquisition parameters, or reconstruction settings. Studies of conventional CT have demonstrated sensitivity of radiomic features to acquisition and reconstruction settings [15,16]. Comparisons using digital phantom and CT/MR patient data have also shown that Image Biomarker Standardisation Initiative (IBSI) compliance does not guarantee agreement between software implementations [17]. These findings motivate technical validation but do not directly establish robustness or variability for the CBCT protocol used here. No external validation across different CBCT hardware and software combinations, reconstruction platforms, or acquisition techniques was performed. No dedicated assessment of radiomic feature repeatability or stability under these variations was conducted. CBCT intensity variability is particularly relevant given the high ranking of intensity-based features. Lee et al. reported improved cross-validated AUC after dentin-based intensity normalisation for differentiating granulomas and radicular cysts [18]. This supports further evaluation of intensity normalisation and harmonisation; it does not validate cross-device transfer of the present models. Transferability to other hardware and software combinations and acquisition protocols remains unestablished.
The semi-automated workflow requires a clinician to identify and manually delineate a lesion before feature extraction and classification; it does not provide automatic lesion detection or segmentation. A potential use, subject to independent validation in a clinically relevant population, would be to present the model output as supplementary information after segmentation of an already identified lesion, with the clinician retaining responsibility for interpretation and management. This is a proposed use scenario, not a clinical application demonstrated by the present study. The current classifier assigns cases to one of three predefined categories and has not been evaluated for lesions outside those categories. No segmentation-time or total processing-time results are reported, and workflow efficiency was not evaluated against routine assessment. Manual segmentation adds an operator-dependent step; whether model assistance saves time or improves decisions remains unknown.
High discriminative performance alone does not imply clinical utility. The radiomic models were not compared directly with expert radiologists interpreting CBCT images or with conventional radiological assessment, including a simple baseline based on radiological and anatomical findings. Consequently, the added diagnostic value of these models over expert interpretation or conventional radiological assessment has not yet been established. High internal classification performance does not demonstrate improved diagnostic decisions or benefit when the models are used alongside routine assessment. The high classification performance may partly reflect the differences in anatomical location and gross radiographic morphology among the three lesion groups. Although anatomical location was not entered as an explicit predictor, the groups were not matched for location or conventional imaging appearance, and these characteristics may be reflected indirectly in the radiomic features extracted from the lesion volumes. Therefore, the present analysis cannot determine whether the models learned lesion-specific quantitative characteristics or relied partly on image patterns associated with anatomical location and morphology. The results should not be interpreted as evidence that the models capture clinically meaningful tissue characteristics beyond those apparent on conventional CBCT assessment. Future studies should evaluate clinically overlapping lesion groups and compare radiomic models with location- and morphology-based approaches and expert interpretation. The study does not identify a clinical situation in which dentists must routinely choose among these three diagnoses using a single classifier. Its restricted three-class task also does not represent the full range of lesions encountered in practice. Accordingly, the potential contribution is hypothesis generation for subsequent studies of clinically competing diagnoses, rather than demonstrated assistance with treatment selection, avoidance of unnecessary intervention, or improved patient outcomes. The involvement of a radiologist in segmentation does not constitute a clinician-performance comparison. Intra- and interobserver reproducibility of lesion segmentation was not assessed; therefore, the potential effect of observer-related variability on the extracted radiomic features and model performance cannot be excluded. Furthermore, calibration of the predicted model probabilities and the potential clinical consequences of misclassifications were not evaluated. Future studies should compare radiomic models, conventional baseline approaches, and experienced readers on the same cases using clearly defined reference standards. Reader studies should assess interpretation both with and without model assistance, alongside calibration, total workflow time, and the consequences of diagnostic errors, before drawing conclusions about added clinical value or efficiency.

5. Conclusions

Machine learning models based on CBCT-derived radiomic features demonstrated high internal discriminative performance among the three lesion groups in this single-centre dataset. However, uncontrolled anatomical and morphological differences, heterogeneous group-specific reference standards, the high feature-to-case ratio, the small internal test cohort, the absence of demonstrated segmentation and feature reproducibility, and the lack of external validation limit interpretation. These findings support proof-of-concept technical feasibility for an exploratory three-class comparison using established methods. They do not establish a clinically viable classification framework or a new AI technology. No direct comparison with expert radiologists or conventional radiological assessment was performed. Superiority over expert interpretation and incremental diagnostic value beyond conventional radiological and anatomical assessment or established radiomic approaches therefore remain unestablished. Independent, multicentre external validation using datasets acquired across different hardware and software combinations and acquisition protocols, together with clinical benchmarking, is required before clinical application. Until such evaluation is available, clinical utility and generalisability remain unestablished.

Author Contributions

Conceptualization, M.E.D. and M.U.; methodology, M.E.D. and M.U.; investigation, M.H.Y.; data curation, M.H.Y.; formal analysis, B.T.Ç.; writing—original draft preparation, M.E.D., M.U., İ.S., M.H.Y. and B.T.Ç.; writing—review and editing, M.E.D., M.U., İ.S., M.H.Y. and B.T.Ç. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Gaziantep University Non-Interventional Clinical Research Ethics Committee (Decision No. 2026/232; 6 May 2026).

Data Availability Statement

The datasets generated and/or analysed during the current study are available from the corresponding author on reasonable request.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
AUCArea Under the Curve
CBCTCone-Beam Computed Tomography
CIConfidence Interval
DICOMDigital Imaging and Communications in Medicine
GLDMGrey-Level Dependence Matrix
GLCMGrey-Level Co-Occurrence Matrix
GLRLMGrey-Level Run-Length Matrix
GLSZMGrey-Level Size-Zone Matrix
ICCIntraclass Correlation Coefficient
IBSIImage Biomarker Standardisation Initiative
KNNK-Nearest Neighbours
LightGBMLight Gradient Boosting Machine
MCCMatthews Correlation Coefficient
NGTDMNeighbouring Grey-Tone Difference Matrix
OvROne-vs-Rest
ROCReceiver Operating Characteristic
ROIRegion of Interest
SVMSupport Vector Machine
VOIVolume of Interest
XGBoostExtreme Gradient Boosting

References

  1. Hadar, T.; Shvero, J.; Nageris, B.I.; Yaniv, E. Mucus retention cyst of the maxillary sinus: The endoscopic approach. Br. J. Oral Maxillofac. Surg. 2000, 38, 227–229. [Google Scholar] [CrossRef] [Scilit]
  2. Senia, E.S.; Sarao, M.S. Periapical cemento-osseous dysplasia: A case report with twelve-year follow-up and review of literature. Int. Endod. J. 2015, 48, 1086–1099. [Google Scholar] [CrossRef] [Scilit]
  3. Yomtako, S.; Watanabe, H.; Kuribayashi, A.; Sakamoto, J.; Miura, M. Differentiation of radicular cysts and radicular granulomas via texture analysis of multi-slice computed tomography images. Dentomaxillofac. Radiol. 2024, 53, 281–288. [Google Scholar] [CrossRef] [Scilit]
  4. Kadam, N.S.; de Ataide, I.d.N.; Raghava, P.; Fernandes, M.; Hede, R. Management of large radicular cyst by conservative surgical approach: A case report. J. Clin. Diagn. Res. 2014, 8, 239–241. [Google Scholar] [CrossRef] [Scilit]
  5. Tian, F.-C.; Bergeron, B.E.; Kalathingal, S.; Morris, M.; Wang, X.Y.; Niu, L.N.; Tay, F.R. Management of large radicular lesions using decompression: A case series and review of the literature. J. Endod. 2019, 45, 651–659. [Google Scholar] [CrossRef] [Scilit]
  6. Thakkar, N.S.; Horner, K.; Sloan, P. Familial occurrence of periapical cemental dysplasia. Virchows Arch. A Pathol. Anat. Histopathol. 1993, 423, 233–236. [Google Scholar] [CrossRef] [Scilit]
  7. İçöz, D.; Çetin, B.; Dinç, K. Application of radiomics features in differential diagnosis of odontogenic cysts. Dentomaxillofac. Radiol. 2025, 54, 180–187. [Google Scholar] [CrossRef] [Scilit]
  8. Sha, X.; Wang, C.; Sun, J.; Qi, S.; Yuan, X.; Zhang, H.; Yang, J. CBCT radiomics features combine machine learning to diagnose cystic lesions in the jaw. Dentomaxillofac. Radiol. 2025, 54, 381–388. [Google Scholar] [CrossRef] [Scilit]
  9. Linton-Reid, K.; Chen, M.; Martell, M.B.; Posma, J.M.; Aboagye, E.O. Radiomics in clinical radiology: Advances, challenges, and future directions. Clin. Radiol. 2026, 92, 107165. [Google Scholar] [CrossRef] [Scilit]
  10. Darbari Kaul, R.; Sacks, P.L.; Thiel, C.; Rimmer, J.; Kalish, L.; Campbell, R.G.; Marín, N.P. Radiomics of the paranasal sinuses: A systematic review of computer-assisted techniques to assess computed tomography radiological data. Am. J. Rhinol. Allergy 2025, 39, 147–158. [Google Scholar] [CrossRef] [Scilit]
  11. Lozano González, Ó.; Salas Orozco, M.F.; Mancera, J.T.; Martínez Cuéllar, N.G.; Patiño Marín, N. Radiomic parameters in periapical lesions: A CBCT analysis evaluating volumetric size, cortical expansion, erosion, and shape. Eur. Endod. J. 2024, 9, 394–404. [Google Scholar] [CrossRef] [Scilit]
  12. Çetin, B.; İçöz, D.; Dinç, K.; Kayadibi, İ. Radiomics-based differential diagnosis of radicular cysts and apical granulomas on CBCT images using RadC-CNN architecture. Diagnostics 2026, 16, 1428. [Google Scholar] [CrossRef] [Scilit]
  13. Duyan Yüksel, H.; Büyük, B.; Evlice, B. Diagnosis of nasopalatine duct and nasopalatine duct cyst in CBCT images: A radiomics-based machine learning approach. Dentomaxillofac. Radiol. 2026, 55, 184–193. [Google Scholar] [CrossRef] [Scilit]
  14. Parmar, C.; Grossmann, P.; Bussink, J.; Lambin, P.; Aerts, H.J.W.L. Machine learning methods for quantitative radiomic biomarkers. Sci. Rep. 2015, 5, 13087. [Google Scholar] [CrossRef] [Scilit]
  15. Midya, A.; Chakraborty, J.; Gönen, M.; Do, R.K.G.; Simpson, A.L. Influence of CT acquisition and reconstruction parameters on radiomic feature reproducibility. J. Med. Imaging 2018, 5, 011020. [Google Scholar] [CrossRef] [Scilit]
  16. Jha, A.K.; Mithun, S.; Jaiswar, V.; Sherkhane, U.B.; Purandare, N.C.; Prabhash, K.; Rangarajan, V.; Dekker, A.; Wee, L.; Traverso, A. Repeatability and reproducibility study of radiomic features on a phantom and human cohort. Sci. Rep. 2021, 11, 2055. [Google Scholar] [CrossRef] [Scilit]
  17. Paquier, Z.; Chao, S.L.; Acquisto, A.; Fenton, C.; Guiot, T.; Dhont, J.; Levillain, H.; Gulyban, A.; Bali, M.A.; Reynaert, N. Radiomics software comparison using digital phantom and patient data: IBSI-compliance does not guarantee concordance of feature values. Biomed. Phys. Eng. Express 2022, 8, 065008. [Google Scholar] [CrossRef] [Scilit]
  18. Lee, Y.; Chen, R.Q.; Yan, H.; Mupparapu, M.; Lure, F.; Li, J.; Setzer, F.C. Dentin-normalized cone-beam computed tomography radiomics within a periapical lesion differential diagnosis system for differentiating granulomas and radicular cysts. J. Endod. 2026, 52, 1861–1868. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.