Skip to Content
LifeLife
  • Article
  • Open Access

25 November 2026

20 Pages

Cardiopulmonary Exercise Testing Profile and Peak Work Rate-Based Screening for Low Fitness in Individuals with Stroke-Related Disability in South Korea

,
and
1
Department of Healthcare and Public Health Research, National Rehabilitation Research Institute, National Rehabilitation Center, Ministry of Health and Welfare, Seoul 01022, Republic of Korea
2
Department of Safety and Health, Wonkwang University, Iksan 54538, Republic of Korea
*
Authors to whom correspondence should be addressed.

Abstract

Background: Low cardiorespiratory fitness after stroke limits physical activity and independence; however, cardiopulmonary exercise testing profiles, including ventilatory indices and comparisons with Korean reference values, have not been described in individuals with stroke in South Korea. Methods: This cross-sectional study analyzed baseline incremental cycle ergometer tests of 45 individuals with stroke from a clinical trial (KCT0005782). Results: Peak oxygen uptake was 16.8 ± 5.5 mL/kg/min, corresponding to 54.2% of the US-derived and 57.8% of the Korean reference values; 37.8% fell below 15 mL/kg/min, a published threshold proposed for independent living. Only 13.3% reached a peak respiratory exchange ratio of ≥1.10, indicating symptom-limited rather than maximal capacity. Age (β = −0.42) and balance function (β = 0.39) were associated with peak oxygen uptake. A peak work rate of ≤48.3 W (failure to complete the 50 W stage) identified low capacity with an area under the curve of 0.95 (apparent sensitivity, 94.1%; specificity, 89.3%; bootstrap optimism-corrected, 89.8% and 87.6%), whereas the American College of Sports Medicine equation showed significant proportional bias. Conclusions: Fitness was approximately half that of healthy Koreans, and peak cycling work rate may be a practical preliminary screening indicator where gas analysis is unavailable, pending external validation.

1. Introduction

Stroke is a leading cause of death and disability worldwide. In 2021, an estimated 93.8 million people were living with stroke and 11.9 million new strokes occurred, with incidence and prevalence rising in East Asia [1]. In South Korea, stroke is the second leading cause of death; although the age-standardized incidence has declined, the total number of stroke events continues to increase because of rapid population aging [2]. Consequently, the number of individuals living in the community with stroke is growing, and long-term maintenance of function and secondary prevention have become central goals of rehabilitation. The American Heart Association and American Stroke Association recommend regular aerobic exercise for stroke survivors and pre-participation exercise testing to ensure safe and individualized exercise prescription [3]. In Korea, the evidence-based clinical practice guideline for stroke rehabilitation has also been revised to emphasize rehabilitation for motor recovery [4].
Cardiorespiratory fitness in stroke survivors is markedly lower than that of age- and sex-matched healthy individuals. A systematic review reported peak oxygen uptake (VO2peak) values of 8–22 mL/kg/min after stroke, corresponding to only 26–87% of those of healthy controls [5]. This reduction reflects a combination of central factors, such as comorbid cardiovascular disease, and peripheral factors, including atrophy of the paretic muscles, changes in muscle fiber type, increased intramuscular fat, and reduced capillary density [6,7]. In a systematic review dominated by Asian patients, the prevalence of sarcopenia increased from 15.8% before stroke to 51.6% within 1 month of onset [7]. Low cardiorespiratory fitness restricts daily physical activity [8] and is associated with post-stroke fatigue [9], creating a vicious cycle of further deconditioning. Moreover, cardiorespiratory fitness is a strong independent predictor of mortality regardless of age, sex, and race, with each 1-MET increase associated with a 14% lower risk of death [10,11]. When VO2peak falls below approximately 15–18 mL/kg/min, maintaining independent daily living becomes difficult [12]. Accurate assessment of cardiorespiratory fitness in individuals with stroke is therefore essential for both functional prognosis and exercise prescription.
Cardiopulmonary exercise testing (CPET) with respiratory gas analysis is the gold standard for assessing cardiorespiratory fitness. In addition to VO2peak, CPET provides indices that help to interpret the mechanisms of exercise limitation, such as ventilatory efficiency (the minute ventilation/carbon dioxide output [V̇E/VCO2] slope), the oxygen uptake efficiency slope (OUES), and end-tidal carbon dioxide pressure [13,14]. Among these, OUES and the V̇E/VCO2 slope are submaximal indices that depend less on maximal effort and are therefore particularly useful in populations that rarely reach maximal exercise [14,15]. However, CPET results in stroke research have mostly focused on VO2peak and heart rate, and ventilatory responses remain poorly characterized [16]. A systematic review of 60 studies also noted that most did not adequately follow CPET guidelines, making comparisons between studies difficult, and a review of measurement properties found little high-quality evidence [17,18]. Cycle ergometry is the most widely used test modality in stroke because it is safe for individuals with balance impairment [17,19].
Four gaps remain in the existing literature. First, most data have been derived from North American and European cohorts [5,16,19,20], and comprehensive CPET profiles including ventilatory indices are lacking for community-dwelling individuals with stroke in South Korea. Moreover, the age-related decline in cardiorespiratory fitness is smaller in healthy Koreans than in Western populations, so percent-predicted values calculated from Western equations may misrepresent the degree of impairment in Koreans [21]; no study has compared the fitness of Korean individuals with stroke against Korean reference values. Second, the effects of age and sex on post-stroke cardiorespiratory fitness are inconsistent; for example, an analysis of 62 individuals with chronic stroke found no sex difference in VO2peak [16]. Third, gas analyzers are rarely available in community rehabilitation settings, and fitness is often estimated from work rate alone, typically with the American College of Sports Medicine (ACSM) leg cycling equation [22]. This equation assumes the mechanical efficiency of healthy individuals, and its validity in stroke, in which exercise efficiency is altered, has not been sufficiently tested. In Korea, two-thirds of community-dwelling individuals with stroke exercise, yet only 21% have ever used a community exercise facility, with concerns about exercise-related accidents and a lack of facilities as the main barriers [23]. A simple and safe fitness screening tool applicable in community settings is therefore needed. Fourth, fitness levels among individuals with stroke are highly heterogeneous, and identifying fitness subgroups could inform future individualized exercise approaches.
Accordingly, this study aimed, in community-dwelling individuals with stroke in South Korea, to (1) comprehensively describe the CPET profile, including ventilatory efficiency and OUES, and its relative level against US-derived and Korean reference values and by sex; (2) examine age-related differences and factors associated with VO2peak; (3) evaluate the accuracy of peak cycling work rate for identifying individuals with a VO2peak below 15 mL/kg/min, a published threshold proposed for independent living, and the agreement of the ACSM metabolic equation; and (4) explore CPET-derived clusters using unsupervised cluster analysis. We hypothesized that VO2peak would be substantially lower than predicted values, that age would be the strongest correlate, and that peak cycling work rate would identify individuals with low fitness with high accuracy.

2. Materials and Methods

2.1. Study Design and Participants

This cross-sectional study analyzed baseline data from an exercise intervention trial registered with the Clinical Research Information Service (CRIS) of the Republic of Korea (KCT0005782), and it is reported in accordance with the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement [24]. The Institutional Review Board of the National Rehabilitation Center approved the protocol (approval number NRC014022015), and all participants provided written informed consent before participation. The trial was conducted in 2015, and its registration with CRIS (14 January 2021) was completed after data collection had ended. The participants in the present analysis were drawn from the same 2015 trial cohort as those in a previously published randomized trial [25], which compared multicomponent exercise with or without power training and reported post-intervention changes in cardiorespiratory fitness, physical function, and muscle strength. The present study used only the baseline (pre-intervention) data of this cohort and reports analyses that were not included in that publication: the complete CPET profile, including ventilatory indices and OUES; comparisons with US-derived and Korean reference values; factors associated with VO2peak; the accuracy of peak work rate for identifying low fitness, with internal validation of the cut-off; agreement of the ACSM equation; and exploratory clustering. All CPET variables were recalculated from the raw data for the present analysis.
Participants were individuals with stroke who were enrolled in the exercise program at the rehabilitation sports center of N Hospital in Seoul, South Korea. The inclusion criteria were (1) a diagnosis of stroke, (2) the ability to follow verbal instructions and communicate, and (3) voluntary participation. The exclusion criteria were (1) neurological disorders other than stroke (e.g., Parkinson’s disease), (2) orthopedic problems of the lower extremities, and (3) other cardiopulmonary diseases. This criterion referred to cardiopulmonary diseases other than stroke; the specific diagnoses were not itemized in the trial records available for this analysis. Participants with elevated blood pressure were not excluded (see Section 3.1). The analysis included 45 participants (29 men and 16 women) whose baseline CPET was performed between 5 June and 9 July 2015; all participants with an analyzable baseline CPET record were included, and screening logs (numbers approached and screened) were not available for this secondary analysis. All 45 baseline tests were included in the analyses of peak variables; slope indices and ΔVO2/ΔWR were available for 44 and 30 tests, respectively (Section 2.3). Clinical characteristics, including stroke type, side of hemiparesis, time since stroke onset, Berg Balance Scale (BBS) score, 6 min walk distance (18 m course), Timed Up and Go (TUG) time, Korean version of the Modified Barthel Index (K-MBI), Korean Trunk Impairment Scale (K-TIS), and isometric knee extension strength of the paretic leg (HUR, Kokkola, Finland), were obtained from the trial records; these data were missing for one participant (6 min walk distance for two). Information on the use of walking aids, lower-limb motor impairment scales, spasticity, recurrent stroke, prior rehabilitation exposure, and habitual physical activity was not available in the trial records. Smoking status, hemoglobin concentration, diagnosed comorbidities (e.g., hypertension, coronary heart disease, and heart failure), medications (e.g., β-blockers), and resting heart rate were likewise not available. Height and body mass were measured, and body mass index (BMI) was calculated as body mass (kg) divided by height squared (m2). BMI was categorized according to the Asia–Pacific criteria (<23, 23–24.9, and ≥25 kg/m2, corresponding to normal weight, overweight, and obesity, respectively), which are recommended for Asian populations because cardiometabolic risk increases at lower BMI values than in European populations [26,27]. Resting systolic and diastolic blood pressure were obtained from the trial records. Balance was assessed with the BBS (0–56 points; higher scores indicate better balance), walking capacity with the 6 min walk test on an 18 m course, functional mobility with the TUG test (time to rise from a chair, walk 3 m, turn, return, and sit down), activities of daily living with the K-MBI (0–100 points), trunk control with the K-TIS (0–23 points), and isometric knee extension strength of the paretic leg with a rehabilitation dynamometer.

2.2. Cardiopulmonary Exercise Testing

Each participant performed a graded exercise test on a cycle ergometer with static wall fixation (Angio CPET, Lode B.V., Groningen, the Netherlands). CPET with respiratory gas analysis is the gold-standard test of cardiorespiratory fitness; it is objective, noninvasive, and widely used in clinical practice [11,13], and it has been reported to be safe and feasible in individuals with stroke [16,19]. Participants wore a face mask, and the gas analysis system (K4b2, COSMED, Rome, Italy) measured respiratory gases continuously on a breath-by-breath basis and stored them as 10 s averages. The K4b2 system has been validated against the Douglas bag method for measuring oxygen uptake over a wide range of exercise intensities [28]. Before each test, we calibrated the gas analyzers with ambient air and a reference gas and calibrated the flowmeter with a 3 L syringe, following the manufacturer’s instructions.
After a 2 min warm-up at 0 W, the work rate was increased by 10 W every minute in a stepwise incremental protocol; participants were instructed to maintain a pedaling cadence of 60 rpm throughout the test. The test was terminated when participants could no longer continue because of fatigue or symptoms or could not maintain 60 rpm for ≥10 s (symptom-limited), in accordance with the ACSM termination criteria [22]. In accordance with these criteria, tests were terminated on the basis of participants’ symptoms and pedaling cadence rather than gas-exchange variables. Heart rate telemetry linked to the gas analyzer yielded valid data in only 7 of the 45 tests; therefore, heart rate-based effort criteria were not applied. Details of seating adjustment, trunk support, foot fixation, assistance to the paretic limb, familiarization, and monitoring of blood pressure, oxygen saturation, and perceived exertion, as well as the reasons for test termination and adverse events, were not systematically documented in the records available for this analysis.

2.3. Derived Variables

All variables were recalculated from the 10 s averaged raw data using a uniform algorithm rather than device-generated values. Before analysis, 10 s intervals with implausible values indicating mask leakage or signal loss (VO2 ≤ 50 mL/min or V̇E ≤ 1 L/min) were removed, and the one test stored breath by breath was averaged into consecutive 10 s bins. Cardiorespiratory fitness was evaluated as VO2peak, defined as the highest 30 s (three consecutive 10 s intervals) rolling average (rolling averages were calculated only when all three intervals were present) and expressed in absolute (mL/min) and relative (mL/kg/min) terms; peak metabolic equivalents (METs) were calculated as VO2peak divided by 3.5. Peak carbon dioxide output (VCO2peak), peak minute ventilation (V̇Epeak), respiratory exchange ratio (RER), respiratory rate, tidal volume, and end-tidal carbon dioxide pressure were each determined independently as the highest 30 s rolling average and could therefore occur at a different time from VO2peak; the dead space to tidal volume ratio was taken from the VO2peak window. Peak work rate was defined operationally as the highest work rate sustained during the test and was calculated using the Kuipers equation to account for partially completed final stages in the stepwise protocol (Equation (1)) [29]:
Wpeak = Wcompleted + (t/60) × 10
where Wcompleted is the work rate (W) of the last completed stage and t is the time (s) spent in the final stage. Predicted VO2max was calculated with the cycle ergometer equation of the Fitness Registry and the Importance of Exercise National Database (FRIEND) (Equation (2)) [30,31]:
VO2maxpred = 45.2 − 0.35 × age − 10.9 × sex − 0.15 × weight(lb) + 0.68 × height(in) − 0.92
where sex is coded as 1 for men and 2 for women, and the last term (0.46 × 2) is the cycle ergometer correction. To evaluate fitness relative to Koreans, sex-specific reference equations derived from 2646 healthy Korean adults were also applied (Equation (3)) [21]. Because these equations are based on treadmill testing, values were converted to cycle-equivalent values by dividing by 1.15, following the conversion used in the original study [21]:
VO2maxKR = (50.54 − 0.26 × age)/1.15 (men); (40.0 − 0.22 × age)/1.15 (women)
Ventilatory efficiency was assessed using the slope of the linear regression of V̇E (L/min) on VCO2 (L/min) during exercise (V̇E/VCO2 slope) and the lowest 30 s average of V̇E/VCO2 (nadir). OUES was calculated as the slope of the regression of VO2 (mL/min) on log10V̇E [15]. The increase in oxygen uptake relative to work rate (ΔVO2/ΔWR) was calculated excluding the first minute of exercise to account for the delay in oxygen uptake kinetics [32]. Slope indices were derived only for tests with ≥60 s of exercise (V̇E/VCO2 slope and OUES; one test was excluded), and ΔVO2/ΔWR only for tests with ≥3 completed work stages (n = 30). End-tidal carbon dioxide pressure (PETCO2) was obtained during the first 30 s of exercise and at its peak, and the dead space to tidal volume ratio (VD/VT) at peak exercise.
The functional thresholds were as follows. A VO2peak of 15 mL/kg/min, proposed in the literature as the minimum required for independent living in older adults [12], was used as a reference threshold for low aerobic fitness; it was not validated against functional independence in this cohort, and values below it indicate reduced aerobic fitness rather than demonstrated functional dependency. Sex-specific thresholds (18 mL/kg/min for men and 15 mL/kg/min for women) were applied in a sensitivity analysis [12]. Values <85% of predicted were defined as reduced cardiorespiratory fitness. A V̇E/VCO2 slope of ≥34 was defined as ventilatory inefficiency [14], and a peak RER of ≥1.10 as attainment of maximal effort [13]. VO2 estimated from work rate was calculated using the ACSM leg cycling equation (Equation (4)) [22]:
VO2 (mL/kg/min) = 1.8 × (W × 6.12)/body mass (kg) + 7
Two tests in which the RER exceeded 1.10 during the first 30 s of exercise were flagged for possible hyperventilation or calibration problems. These tests were retained in the main analysis and excluded in a sensitivity analysis to examine the robustness of the results.

2.4. Statistical Analysis

Continuous variables are presented as mean ± standard deviation and median (interquartile range), and categorical variables as frequency (%) with Wilson 95% confidence intervals (CIs). Normality was assessed using the Shapiro–Wilk test. Sex differences were compared using Welch’s t-test or the Mann–Whitney U test, with Cohen’s d as the effect size, and the Holm method was applied to correct for multiple comparisons across 21 CPET variables. Percent-predicted values based on the FRIEND and Korean references were compared using the Wilcoxon signed-rank test. Age groups (<50, 50–64, and ≥65 years) were compared using one-way analysis of variance when normality and homogeneity of variance (Levene’s test) were satisfied and the Kruskal–Wallis test otherwise, followed by Bonferroni-corrected Mann–Whitney U tests; associations with age as a continuous variable were assessed using Spearman’s correlation (ρ). Partial correlations adjusted for age and sex were used to examine associations between VO2peak and other indices.
Factors associated with VO2peak (mL/kg/min) were examined using multiple linear regression with age, sex, and body mass index (Model 1); these analyses were exploratory and describe statistical associations rather than independent biological determinants. A prediction equation was derived by adding peak work rate (Model 2). To examine stroke-specific correlates, BBS score, time since onset (log-transformed), stroke type, and side of hemiparesis were added to Model 1 using complete cases, and a final model retaining age, sex, and BBS score was fitted (Model 3). Regression assumptions were checked using variance inflation factors (VIFs), the Shapiro–Wilk test of residuals, the Breusch–Pagan test, and Cook’s distance, and heteroscedasticity-robust (HC3) standard errors were also calculated. The prediction model was internally validated using the bootstrap optimism-corrected coefficient of determination (R2; 1000 resamples) and the leave-one-out cross-validated root mean square error (RMSE). The two simplified equations (Equations (5) and (6)) were validated separately in the same manner; for Equation (6), the predicted absolute VO2peak was divided by each participant’s body mass so that R2 and RMSE were calculated on the relative (mL/kg/min) scale.
The ability of peak work rate (W and W/kg) to identify a VO2peak of <15 mL/kg/min was evaluated using the area under the receiver-operating characteristic (ROC) curve (AUC), with 95% CIs from 2000 bootstrap resamples; the optimal cut-off was determined using the Youden index [33]. Because the cut-off was selected and evaluated in the same sample, the entire selection procedure was internally validated: in each of 1000 bootstrap samples, the Youden-optimal cut-off was re-selected, and its sensitivity and specificity in the bootstrap sample were compared with those obtained by applying it to the original sample to estimate optimism; the distribution of re-selected cut-offs was summarized, and leave-one-out cross-validation was performed by re-selecting the cut-off without each participant and classifying that participant. Agreement between ACSM-estimated and measured VO2peak was assessed using Bland–Altman analysis [34]; proportional bias was tested by regressing the differences in the means, and the intraclass correlation coefficient for absolute agreement ICC(2,1),was calculated [35]. The VO2 response to work rate was analyzed using the average of the last 30 s of each stage completed for ≥40 s in a linear mixed-effects model with random intercepts and slopes. Stage-level ACSM estimates were calculated with each participant’s body mass before averaging. Because fewer participants contributed at higher stages, the within-person difference between measured and ACSM-estimated VO2 was also modeled against work rate (linear mixed-effects model with random intercepts), and the comparison was repeated in participants who reached ≥60 W.
Exploratory CPET-derived clusters were identified using k-means cluster analysis of five standardized variables (VO2peak/kg, peak work rate, OUES/kg, V̇E/VCO2 slope, and peak RER). The number of clusters (k = 2–5) was selected using the silhouette coefficient, robustness was examined against Ward’s hierarchical clustering using the adjusted Rand index (ARI), and the results were visualized using principal component analysis. Between-cluster comparisons of the clustering variables are descriptive and were not used to validate the clusters. Two-sided p < 0.05 was considered significant. Analyses were performed using Python 3.12 (SciPy 1.17, statsmodels 0.15, pingouin 0.7, and scikit-learn 1.8).

3. Results

3.1. Participant Characteristics

Of the 45 participants, 29 (64.4%) were men, and the mean age was 55.4 ± 12.0 years (range, 20–77 years). The mean body mass index was 24.9 ± 3.5 kg/m2, and 40.0% had a body mass index of ≥25 kg/m2. Men were taller and heavier than women, whereas age, age-group distribution, and body mass index did not differ by sex (Table 1). Of the participants with available clinical data, 24 had hemorrhagic stroke and 24 had left hemiparesis; the median time since onset was 24 months (interquartile range [IQR] 11–102; range 4–261), and the median BBS score was 49 (IQR 40–52). The median 6 min walk distance was 256.5 m (IQR 182.7–326.7), the TUG time was 15.2 s (10.4–18.4), the K-MBI score was 93 (88.8–97.0), and paretic knee extension strength was 14.0 kg (6.9–20.9). Resting systolic and diastolic blood pressure were 124.5 ± 13.1 and 79.9 ± 9.9 mmHg, respectively (n = 44), and 11 participants (25.0%) had values of ≥140/90 mmHg. These characteristics did not differ by sex.
Table 1. Characteristics of the participants.

3.2. Cardiopulmonary Exercise Testing Profile and Sex Differences

The median test duration was 320 s (5.3 min), and the peak work rate was 56.9 ± 26.8 W (0.87 ± 0.38 W/kg). VO2peak was 1107 ± 436 mL/min and 16.8 ± 5.5 mL/kg/min (4.8 ± 1.6 METs), corresponding to 54.2 ± 19.2% of the FRIEND-predicted value and 57.8 ± 16.0% of the Korean reference value (Table 2). The Korean predicted value was on average 3.0 mL/kg/min lower than the FRIEND-predicted value, and the percent-predicted values differed significantly between the two references (Wilcoxon p < 0.001). The peak RER was 1.01 ± 0.10; only 6 participants (13.3%) reached ≥1.10, and 24 (53.3%) reached ≥1.00. Because few participants met the maximal-effort criterion and 26 (57.8%) exercised for <6 min, VO2peak in this study represents a symptom-limited peak value that may underestimate maximal cardiorespiratory capacity. The V̇E/VCO2 slope was 30.8 ± 4.4, mostly within the normal range, and ΔVO2/ΔWR was 12.3 ± 2.8 mL/min/W.
Table 2. Cardiopulmonary exercise testing profile of individuals with stroke (N = 45).
Men had greater absolute exercise capacity than women, including peak work rate (d = 1.19), absolute VO2peak (d = 0.90), V̇Epeak (d = 1.02), and peak tidal volume (d = 1.44), and these differences remained significant after correction for multiple comparisons (Figure 1). Relative VO2peak was higher in men (18.0 vs. 14.5 mL/kg/min, p = 0.030), but this difference was not significant after correction (Holm p = 0.360). Percent-predicted VO2peak based on FRIEND tended to be higher in women (62.5% vs. 49.7%, p = 0.066), but this tendency disappeared when the Korean reference was applied (men, 56.2%; women, 60.8%; p = 0.395). The V̇E/VCO2 slope, V̇E/VCO2 nadir, OUES/kg, and ΔVO2/ΔWR did not differ by sex.
Figure 1. Distribution of key cardiopulmonary exercise testing indices by sex. (A) VO2peak (dashed lines, 15 and 18 mL/kg/min); (B) peak work rate; (C) V̇E/VCO2 slope (dashed line, 34); (D) VO2peak as a percentage of the FRIEND-predicted value (dashed line, 85%). Boxes indicate medians and interquartile ranges, and dots indicate individual values.

3.3. Age-Related Differences and Factors Associated with Peak Oxygen Uptake

VO2peak decreased stepwise across age groups (<50 years, 19.6; 50–64 years, 17.1; ≥65 years, 12.1 mL/kg/min; p = 0.001), and the ≥65-year group had significantly lower values than both younger groups (Table 3). Peak work rate, V̇Epeak, and OUES showed the same pattern. Percent-predicted VO2peak based on FRIEND did not differ across age groups (p = 0.076; ρ = −0.18), whereas with the Korean reference, the ≥65-year group (47.8%) had a significantly lower percentage than the 50–64-year group (61.9%; p = 0.045). Thus, compared with the Korean reference, in which the age-related decline is smaller, older individuals with stroke showed greater impairment not only in absolute but also in relative fitness (Figure 2). The V̇E/VCO2 slope was positively correlated with age (ρ = 0.40), although the difference across age groups was not significant (p = 0.067). The proportion with a VO2peak of <15 mL/kg/min was 81.8% in the ≥65-year group, markedly higher than in those aged <50 years (20.0%) and 50–64 years (26.3%; p = 0.002).
Table 3. Cardiopulmonary exercise testing indices by age group.
Figure 2. Measured VO2peak and US-derived and Korean reference values by age. Dots and solid lines indicate measured values and sex-specific regression lines; dotted lines indicate FRIEND cycle-predicted values calculated using sex-specific mean body size; dash-dotted lines indicate Korean reference values converted to cycle-equivalent values [21]. The gray dashed line indicates 15 mL/kg/min.
In partial correlations adjusted for age and sex, VO2peak was strongly associated with peak work rate (r = 0.80, 95% CI 0.66–0.89) and OUES (r = 0.65, 95% CI 0.43–0.80), but not with body mass index (r = 0.09, p = 0.548) or the V̇E/VCO2 slope (r = −0.01, p = 0.969). In multiple regression (Model 1), age was most strongly associated with VO2peak (standardized β = −0.54, p < 0.001), with VO2peak decreasing by 0.25 mL/kg/min per year of age (Table 4). Male sex was associated with higher VO2peak at a borderline level (β = 0.25, p = 0.047; HC3 p = 0.061), and body mass index was not significant. The three variables explained 39.5% of the variance in VO2peak. All VIFs were ≤1.02, residual normality (p = 0.46) and homoscedasticity (p = 0.51) were satisfied, and the maximum Cook’s distance was 0.26.
Table 4. Multiple linear regression analysis for VO2peak (mL/kg/min).
Among the clinical characteristics, VO2peak did not differ by stroke type (hemorrhagic, 16.5 ± 4.8; ischemic, 16.7 ± 6.2 mL/kg/min; p = 0.908) or side of hemiparesis (right, 15.2 ± 4.6; left, 17.7 ± 5.9 mL/kg/min; p = 0.123) and was not correlated with time since onset (ρ = 0.02, p = 0.891), whereas it was positively correlated with BBS score (ρ = 0.58, p < 0.001; partial ρ adjusted for age and sex = 0.49, p = 0.001). When BBS score, time since onset, stroke type, and side of hemiparesis were added to Model 1, only age and BBS score remained significant (R2 = 0.545). In Model 3, age (β = −0.42, p = 0.001), BBS score (β = 0.39, p = 0.002), and male sex (β = 0.24, p = 0.042) together explained 50.4% of the variance in VO2peak, 13.6 percentage points more than Model 1 fitted to the same participants (Table 4). Participants with a BBS score of ≤40 had lower VO2peak than those with a score of >40 (12.9 ± 4.4 vs. 17.9 ± 5.2 mL/kg/min, p = 0.008), and 9 of 12 (75.0%) were below 15 mL/kg/min. Resting systolic and diastolic blood pressure were not associated with VO2peak after adjustment for age and sex (partial r = 0.23, p = 0.146, and r = 0.12, p = 0.443, respectively), VO2peak did not differ between participants with and without blood pressure of ≥140/90 mmHg (16.5 vs. 16.6 mL/kg/min, p = 0.978), and adding systolic blood pressure to Model 3 did not materially change the coefficients for age or BBS score (BBS, B = 0.241, p = 0.002).
In Model 2, which added peak work rate, only peak work rate was a significant predictor (β = 0.88), and age, sex, and body mass index were no longer significant. The model explained 78.1% of the variance (optimism-corrected R2 = 0.73), with a standard error of the estimate of 2.69 and a cross-validated RMSE of 2.99 mL/kg/min. The simple prediction equation using peak work rate alone is given in Equation (5) (R2 = 0.751; standard error of the estimate, 2.77), and the equation for absolute VO2peak in Equation (6) (R2 = 0.839; standard error of the estimate, 179 mL/min):
VO2peak (mL/kg/min) = 6.66 + 0.177 × peak work rate (W)
VO2peak (mL/min) = −471 + 12.12 × peak work rate (W) + 13.59 × body mass (kg)
When validated separately, Equation (5) had an optimism-corrected R2 of 0.74 and a leave-one-out RMSE of 2.91 mL/kg/min. When the predictions of Equation (6) were divided by each participant’s body mass, the relative-scale R2 was 0.79 (optimism-corrected, 0.77) and the leave-one-out RMSE was 2.71 mL/kg/min. Across participants, the relative VO2peak predicted by Equation (6) differed from that predicted by Equation (5) by −2.9 to +1.5 mL/kg/min, and the difference was inversely correlated with body mass (r = −0.61), indicating that the same absolute work rate corresponds to a lower relative VO2peak in heavier individuals.

3.4. Functional Fitness Classification and Screening by Peak Work Rate

Overall, 37.8% of participants had a VO2peak of <15 mL/kg/min, and 42.2% (men, 41.4%; women, 43.8%) fell below the sex-specific thresholds (18 mL/kg/min for men and 15 mL/kg/min for women) (Table 5). Peak METs were <5 in 48.9%, VO2peak was <85% of predicted in 95.6% according to both references, and 25.0% had a V̇E/VCO2 slope of ≥34. The proportion below 15 mL/kg/min did not differ by sex (34.5% vs. 43.8%, Fisher p = 0.749).
Table 5. Classification against published fitness thresholds and accuracy of peak work rate for identifying low capacity (N = 45).
Peak work rate showed excellent apparent discrimination for a VO2peak of <15 mL/kg/min (AUC 0.95, 95% CI 0.87–1.00; Figure 3). At the Youden-optimal cut-off of ≤48.3 W, which in this protocol corresponds to failure to complete the 50 W stage (≤50 s at 50 W), the apparent sensitivity, specificity, positive predictive value, and negative predictive value were 94.1% (16/17), 89.3% (25/28), 84.2% (16/19), and 96.2% (25/26), respectively. After internal validation that re-selected the cut-off in each bootstrap sample, the optimism-corrected sensitivity and specificity were 89.8% and 87.6%, respectively; the re-selected cut-off had a median of 48.3 W (IQR 43.3–48.3 W; 95% range 36.7–55.0 W). In leave-one-out cross-validation with re-selection of the cut-off, sensitivity was 82.4% (14/17) and specificity 89.3% (25/28). Peak work rate relative to body mass (cut-off ≤ 0.74 W/kg) showed similar discrimination (AUC 0.94, 95% CI 0.85–1.00).
Figure 3. Receiver-operating characteristic curves of peak work rate (W) and peak work rate per body mass (W/kg) for identifying a VO2peak of <15 mL/kg/min. The red dot indicates the Youden-optimal cut-off (≤48.3 W; apparent sensitivity 94.1%, specificity 89.3%).

3.5. Work Rate–Oxygen Uptake Relationship and Agreement of the ACSM Equation

In the linear mixed-effects model, the increase in VO2 with work rate was 0.183 mL/kg/min/W (95% CI 0.172–0.195), with an intercept of 6.08 mL/kg/min (Figure 4A). At low work rates (10–40 W), measured VO2 was 0.5–1.0 mL/kg/min lower than the ACSM estimate, whereas it was higher at ≥70 W. Within participants, the difference between measured and ACSM-estimated VO2 increased by 0.20 mL/kg/min per 10 W (p < 0.001), and among the 21 participants who reached ≥60 W, the difference was −0.89, −0.34, and 0.00 mL/kg/min at 20, 40, and 60 W, respectively, indicating that the pattern was not explained solely by the change in the contributing sample at higher stages. In the Bland–Altman analysis, the mean bias between ACSM-estimated and measured VO2peak was small (−0.17 mL/kg/min, 95% CI −1.00 to 0.67, p = 0.688), with 95% limits of agreement of −5.62 to 5.29 mL/kg/min (Figure 4B). However, proportional bias was significant (slope −0.28, p = 0.001): the ACSM equation overestimated VO2peak by 1.63 ± 0.82 mL/kg/min in the lowest tertile and underestimated it by 2.08 ± 3.37 mL/kg/min in the highest tertile. The ICC(2,1) was 0.84 (95% CI 0.73–0.91), but only 60.0% of the estimates were within ±10% of the measured values.
Figure 4. Work rate–oxygen uptake relationship and agreement of the ACSM equation. (A) VO2 during the last 30 s of each stage. Gray lines indicate individuals, the black line indicates the mean ± standard deviation, and the orange dashed line indicates the mean of ACSM leg cycling estimates calculated with each participant’s body mass; the numbers at the bottom indicate the participants who completed ≥40 s at each stage (stages with n ≥ 5 are shown). (B) Bland–Altman plot of ACSM-estimated versus measured VO2peak. The solid line indicates the mean bias, the dashed lines indicate the 95% limits of agreement, and the orange line indicates the proportional-bias regression.

3.6. Exploratory CPET-Derived Clusters

In the k-means cluster analysis, the two-cluster solution had the highest silhouette coefficient (0.32; indicating limited separation), whereas the three-cluster solution separated only a single outlier. Agreement with Ward’s hierarchical clustering was good (ARI 0.74). The first principal component (54.8% of variance) represented aerobic capacity, characterized by VO2peak, peak work rate, and OUES/kg, and the second (24.9%) reflected RER and the V̇E/VCO2 slope (Figure 5). Compared with the moderate-fitness cluster (n = 20), the low-fitness cluster (n = 24) was older (61.0 vs. 48.3 years), included more women (50.0% vs. 15.0%) and more individuals aged ≥65 years (41.7% vs. 5.0%), and had a higher V̇E/VCO2 slope and lower peak RER (Table 6). Because these indices were clustering variables, their between-cluster differences are expected by construction and do not validate the clusters. All participants with a VO2peak of <15 mL/kg/min belonged to the low-fitness cluster. The low-fitness cluster also had lower BBS scores than the moderate-fitness cluster (42.8 ± 9.2 vs. 50.2 ± 4.2, p = 0.003), whereas stroke type, side of hemiparesis, and time since onset did not differ.
Figure 5. Two exploratory CPET-derived clusters shown in the principal component space of five indices. The first principal component reflects aerobic capacity, and the second reflects higher RER and lower V̇E/VCO2 slope.
Table 6. Characteristics of exploratory CPET-derived clusters.

3.7. Sensitivity Analyses

Excluding the two flagged tests yielded nearly identical VO2peak values (16.9 ± 5.4 mL/kg/min, n = 43) and regression coefficients (age, −0.239; sex, 2.62). When the analysis was restricted to the 24 participants who reached a peak RER of ≥1.00, VO2peak was 18.6 ± 6.0 mL/kg/min and peak work rate was 69.4 W.

4. Discussion

This study comprehensively described the CPET profile, including ventilatory indices, of community-dwelling individuals with stroke in South Korea and, for the first time, compared it with Korean reference values. There were five main findings. First, VO2peak was about half the predicted value according to both US-derived and Korean references, and four in ten participants fell below a published threshold proposed for independent living (15 mL/kg/min). Second, age and balance function were the main correlates of VO2peak, and against the Korean reference, older individuals also showed greater relative impairment. Third, most participants terminated the test before reaching the maximal effort criterion, whereas ventilatory efficiency was relatively preserved. Fourth, a peak cycling work rate of ≤48.3 W (failure to complete the 50 W stage) identified low-fitness individuals with high apparent accuracy that remained good after internal validation of the cut-off selection, whereas the ACSM equation showed significant proportional bias. Fifth, an exploratory low-fitness cluster predominantly comprising older adults and women was identified.
The VO2peak in this study (16.8 mL/kg/min) and its percentage of the predicted value (54%) fall within the range reported in a systematic review (8–22 mL/kg/min, or 26–87% of healthy controls) [5]. They are also similar to those of a North American chronic stroke cohort tested on a cycle ergometer [16] and to the baseline value of the exercise group in a randomized trial of community-dwelling individuals more than 6 months after stroke (18 ± 5 mL/kg/min) [20]. These findings confirm that cardiorespiratory fitness is markedly reduced in individuals with stroke in South Korea. More clinically important is that about half of the participants had peak METs of <5. Because daily activities such as brisk walking and stair climbing require 3–5 METs [22], these individuals use a large proportion of their maximal capacity for ordinary activities, which can lead to a vicious cycle of fatigue, activity avoidance, and further deconditioning [8,9].
The analysis using Korean reference values has important implications for clinical practice in Korea. Because the age-related decline in cardiorespiratory fitness is smaller in healthy Koreans than in Western populations, Western equations set relatively low predicted values for older Koreans [21]. Indeed, with the FRIEND reference, percent-predicted VO2peak did not differ across age groups and tended to be higher in women, whereas with the Korean reference, the sex difference disappeared and the relative impairment of those aged ≥65 years became evident. This suggests that relying solely on Western equations may underestimate the fitness loss of older individuals with stroke. In the same reference study, directly measured VO2max values of Korean patients with coronary heart disease were 25.9 mL/kg/min in men in their 50s, 25.5 mL/kg/min in men in their 60s, and 22.3 mL/kg/min in women in their 60s [21]. When the values of our participants were converted to treadmill-equivalent values in the same manner (×1.15), they were 21.0, 17.0, and 14.9 mL/kg/min, respectively, lower even than those of patients with coronary heart disease, the primary target population of cardiac rehabilitation. Although the small number of participants in each age stratum warrants caution, this result suggests that individuals with stroke in Korea require systematic fitness assessment and exercise intervention comparable to or exceeding those provided in cardiac rehabilitation. However, the Korean reference values were estimated from treadmill performance rather than measured by gas analysis, and we applied a further conversion (÷1.15) to obtain cycle-equivalent values; comparisons with this reference should therefore be regarded as approximate.
Only 13.3% of participants reached the maximal effort criterion (RER ≥ 1.10), and the median test duration was 5.3 min. In contrast, the mean V̇E/VCO2 slope was 30.8, with 75% of participants in the normal range, and it was not associated with VO2peak after adjustment for age and sex. This suggests that many participants stopped exercising before reaching their cardiopulmonary limits, possibly because of motor impairment, fatigue of the paretic lower limb, or inability to maintain the required cadence. However, reasons for termination were not systematically recorded, and without measurements such as cardiac output or muscle oxygenation, the principal limiting factor cannot be determined. VO2peak values in this study should therefore be interpreted as symptom-limited peak values that may underestimate maximal cardiorespiratory capacity, particularly in participants with short tests. A peripheral contribution would be consistent with reports of changes in muscle mass and fiber characteristics after stroke [6] and with the rapid increase in sarcopenia after onset reported in a review dominated by Asian patients [7]. It also agrees with a randomized trial in which training-induced improvements in VO2peak were explained by an increase in the arteriovenous oxygen difference rather than cardiac output [20], and with the report that individuals with stroke are less likely than those with coronary artery disease to reach an intensity sufficient for exercise prescription [19]. In such settings, OUES, which depends less on maximal effort, may be a useful complementary index [14,15]; in this study, OUES was strongly correlated with VO2peak after adjustment for age and sex (r = 0.65).
Balance function was the only stroke-specific characteristic associated with VO2peak after adjustment for age and sex. Stroke type, side of hemiparesis, and time since onset were not related to VO2peak, whereas each 10-point higher BBS score corresponded to an approximately 2.5 mL/kg/min higher VO2peak, independent of age and sex. This is consistent with, but does not establish, a role of neuromuscular impairment, rather than the type or chronicity of stroke, in limiting exercise capacity in this population [6,20]. Moreover, three-quarters of participants with a BBS score of ≤40 were below the 15 mL/kg/min threshold, indicating that individuals with poor balance may warrant priority for fitness assessment.
Age was most strongly associated with VO2peak, and 82% of those aged ≥65 years were below the threshold. Because the 15 mL/kg/min threshold is an absolute value, older individuals cross it first when stroke-related loss is added to age-related decline. Even in healthy individuals, VO2max declines by about 5 mL/kg/min per decade [12], and as noted above, older individuals had greater relative impairment compared with the Korean reference. Older individuals with stroke therefore carry the double burden of aging and stroke and may warrant priority for fitness assessment and intervention; whether their low aerobic fitness translates into functional dependency was not assessed in this study.
Sex differences were observed mainly in absolute body-size-related indices. Men had higher peak work rate, absolute VO2peak, V̇Epeak, and tidal volume, but the difference in relative VO2peak was not significant after multiple-comparison correction. This is consistent with a chronic stroke study that found no sex difference in VO2peak but greater ventilation and tidal volume in men [16]. Nevertheless, women had lower absolute fitness and were overrepresented in the exploratory low-fitness cluster; whether sex-specific assessment criteria are needed should be examined in larger samples.
A quarter of participants had a V̇E/VCO2 slope of ≥34, and this index was positively correlated with age. In heart failure and cardiovascular disease, a high V̇E/VCO2 slope predicts poor prognosis [14]. In individuals with stroke, ventilatory inefficiency may reflect comorbid cardiopulmonary disease or abnormal ventilatory control, so this subgroup may warrant further cardiovascular evaluation. The prognostic significance of this index in stroke remains unestablished.
The most practical contribution of this study is a preliminary criterion for identifying individuals with low fitness without gas analysis. Peak cycling work rate explained 75% of the variance in VO2peak, and a cut-off of ≤48.3 W (failure to complete the 50 W stage) identified a VO2peak of <15 mL/kg/min with an AUC of 0.95 and an apparent negative predictive value of 96.2%; that is, in this sample, individuals who completed the 50 W stage were unlikely to have a VO2peak below this threshold. Because the cut-off was selected in the same sample, the optimism-corrected sensitivity (89.8%) and specificity (87.6%) are more realistic estimates, and the threshold should be regarded as preliminary until externally validated. It is also protocol-dependent: it was obtained with 10 W/min stages on a wall-fixed ergometer at 60 rpm, and work rate and VO2peak were measured during the same symptom-limited test, so a gas-free assessment would need to reproduce the protocol, cadence requirement, and termination criteria. Moreover, an absolute work rate does not account for body size—48.3 W corresponds to 0.97 W/kg in a 50 kg individual but 0.60 W/kg in an 80 kg individual—and Equation (6) indicated that the same work rate corresponds to a lower relative VO2peak in heavier individuals. After external validation, this criterion could serve as a simple screening indicator in community rehabilitation institutions, public health centers, and sports facilities for people with disabilities in Korea, where gas analyzers are rarely available. Given that concern about accidents during exercise is a main reason why Korean individuals with stroke avoid community exercise facilities [23], objectively confirming fitness with a simple cycle test and providing a safe exercise intensity may also help to increase facility use. In contrast, the ACSM equation was accurate at the group level but showed proportional bias, overestimating VO2peak by approximately 1.6 mL/kg/min (approximately 0.5 MET) in those with the lowest fitness. If exercise intensity is set as a percentage of the estimated VO2peak, the most vulnerable individuals may be prescribed a higher intensity than intended. This bias can be explained by the failure to reach a steady state at low work rates in the 1 min stage protocol and by the increased oxygen cost at higher work rates due to factors such as co-contraction; the within-person analysis showed that this pattern was not merely a consequence of fewer participants contributing at higher stages. Indeed, ΔVO2/ΔWR (12.3 mL/min/W) was higher than the commonly reported value of approximately 10 mL/min/W [32]. The stroke-specific prediction equations derived in this study (optimism-corrected R2 0.74–0.77) could complement the ACSM equation in practice after external validation.
The exploratory cluster analysis suggested two groupings with limited separation. All participants below the threshold belonged to the low-fitness cluster, which had a higher proportion of older adults and women and a higher V̇E/VCO2 slope. Because treatment responses and training tolerance were not evaluated, these clusters should not be used to assign specific exercise prescriptions; whether such groups differ in their response to training requires prospective testing. Existing evidence indicates that combined aerobic and resistance training improves both cardiorespiratory fitness and muscle strength after stroke [36], that high-intensity walking training is effective in chronic stroke [37], and that aerobic and mixed training improve VO2peak by 3.16 mL/kg/min on average, with moderate-to-high-intensity sessions of 45 min, three times per week for at least 8 weeks recommended [38,39].
This study has several strengths. CPET was directly measured in individuals with stroke, and all indices were recalculated from raw data using a standardized algorithm rather than device-generated values. Multiple aspects were analyzed, including ventilatory efficiency, OUES, functional thresholds, screening accuracy, equation validity, exploratory clusters, and comparison with Korean reference values, and the robustness of the results was confirmed with internal validation and sensitivity analyses.
This study also has limitations. First, the sample of 45 participants from a single program limits generalization to all individuals with stroke in Korea. Second, stroke severity was characterized by balance, walking, trunk function, daily living, and paretic knee strength. Motor impairment scales, spasticity, use of walking aids, comorbidities, medications, and habitual physical activity were not available, nor were smoking status, hemoglobin concentration, β-blocker use, and resting heart rate, which can influence VO2peak and heart rate responses; these factors could therefore not be examined as potential confounders, although resting blood pressure was not associated with VO2peak. Third, the 1 min stage protocol did not allow a steady state at low work rates, and because many tests were short, most participants’ ventilatory threshold could not be reliably determined; furthermore, few participants met the maximal-effort criterion, valid heart rate data were available for only 7 tests, and test positioning, monitoring, reasons for termination, and adverse events were not systematically documented, so VO2peak represents a symptom-limited value whose limiting factors could not be identified. Fourth, the Korean reference values were estimated from treadmill performance rather than measured by gas analysis and were further converted to cycle-equivalent values (÷1.15) and may therefore contain error, and the threshold for independent living was derived from data on older adults and was not validated against functional independence in this cohort; actual independence in daily living and subsequent dependency were not assessed; cycle-based CPET reference values for Korean adults are needed. Fifth, the screening cut-off was derived and evaluated in the same sample; although internal validation that re-selected the cut-off reduced optimism, the cut-off is protocol-dependent and requires external validation. Sixth, the regression and cluster analyses were exploratory, and the cluster-based groupings were not tested against treatment response or outcomes. Finally, the cross-sectional design precludes causal inference. Future multicenter studies in Korean cohorts of individuals with stroke, including clinical information and standardized ramp protocols in accordance with guidelines [13,17], are needed to externally validate the screening criterion and prediction equation proposed here.

5. Conclusions

The cardiorespiratory fitness of community-dwelling individuals with stroke in South Korea is approximately half of the predicted value according to both US-derived and Korean references, and four in ten fall below a published aerobic fitness threshold proposed for independent living. Age and balance function, but not stroke type or time since onset, were associated with VO2peak. Low aerobic fitness was concentrated among those aged ≥65 years, and using only Western equations may underestimate the relative impairment of older individuals. Most participants stopped before reaching the maximal effort criterion, while ventilatory efficiency remained relatively preserved; thus, the measured values represent symptom-limited peak capacity. A peak cycling work rate of ≤48.3 W (failure to complete the 50 W stage) is a promising but preliminary, protocol-dependent criterion for identifying individuals with low fitness without gas analysis, whereas the ACSM equation overestimates fitness in those with low capacity and should be used with caution for exercise prescription. These findings provide a basis for community-based fitness assessment in individuals with stroke in Korea; the screening criterion and prediction equations require external validation, and the implications for functional independence and training response remain to be tested.

Author Contributions

Conceptualization, D.K., S.-D.E. and J.P.; methodology, D.K. and J.P.; formal analysis, D.K. and J.P.; investigation, D.K.; data curation, D.K.; writing—original draft preparation, D.K.; writing—review and editing, D.K. and J.P.; visualization, D.K.; project administration, D.K. and S.-D.E.; funding acquisition, S.-D.E. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Korea National Rehabilitation Research Institute, Korea National Rehabilitation Center, Ministry of Health and Welfare (grant number 15-C-01).

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Board of the National Rehabilitation Center (protocol code NRC014022015; date of approval: 14 April 2015). The analyzed data were obtained at baseline from a trial registered with the Clinical Research Information Service (KCT0005782; date of registration: 14 January 2021).

Data Availability Statement

The data presented in this study are available on request from the corresponding author due to privacy restrictions.

Acknowledgments

The authors thank all participants for their time and effort.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

ACSMAmerican College of Sports Medicine
AUCarea under the curve
BBSBerg Balance Scale
CIconfidence interval
CPETcardiopulmonary exercise testing
FRIENDFitness Registry and the Importance of Exercise National Database
ICCintraclass correlation coefficient
METsmetabolic equivalents
OUESoxygen uptake efficiency slope
PETCO2end-tidal carbon dioxide pressure
RERrespiratory exchange ratio
RMSEroot mean square error
ROCreceiver-operating characteristic
VD/VTdead space to tidal volume ratio
V̇Eminute ventilation
VCO2carbon dioxide output
VO2peakpeak oxygen uptake
ΔVO2/ΔWRincrease in oxygen uptake relative to work rate

References

  1. GBD 2021 Stroke Risk Factor Collaborators. Global, regional, and national burden of stroke and its risk factors, 1990–2021: A systematic analysis for the Global Burden of Disease Study 2021. Lancet Neurol. 2024, 23, 973–1003. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Moon, J.; Seo, Y.; Lee, H.H.; Lee, H.; Kaneko, F.; Shin, S.; Kim, E.; Yum, K.S.; Kim, Y.D.; Baek, J.H.; et al. Incidence and case fatality of stroke in Korea, 2011–2020. Epidemiol. Health 2024, 46, e2024003. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Billinger, S.A.; Arena, R.; Bernhardt, J.; Eng, J.J.; Franklin, B.A.; Johnson, C.M.; MacKay-Lyons, M.; Macko, R.F.; Mead, G.E.; Roth, E.J.; et al. Physical activity and exercise recommendations for stroke survivors: A statement for healthcare professionals from the American Heart Association/American Stroke Association. Stroke 2014, 45, 2532–2553. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Kim, D.Y.; Ryu, B.; Oh, B.M.; Kim, D.Y.; Kim, D.S.; Kim, D.Y.; Kim, D.K.; Kim, E.J.; Lee, H.Y.; Choi, H.; et al. Clinical practice guideline for stroke rehabilitation in Korea—Part 1: Rehabilitation for motor function (2022). Brain Neurorehabil 2023, 16, e18. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Smith, A.C.; Saunders, D.H.; Mead, G. Cardiorespiratory fitness after stroke: A systematic review. Int. J. Stroke 2012, 7, 499–510. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Billinger, S.A.; Coughenour, E.; MacKay-Lyons, M.J.; Ivey, F.M. Reduced cardiorespiratory fitness after stroke: Biological consequences and exercise-induced adaptations. Stroke Res. Treat. 2012, 2012, 959120. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Inoue, T.; Ueshima, J.; Kawase, F.; Kobayashi, H.; Nagano, A.; Murotani, K.; Saino, Y.; Maeda, K. Trajectories of the prevalence of sarcopenia in the pre- and post-stroke periods: A systematic review. Nutrients 2023, 15, 113. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Fini, N.A.; Holland, A.E.; Keating, J.; Simek, J.; Bernhardt, J. How physically active are people following stroke? Systematic review and quantitative synthesis. Phys. Ther. 2017, 97, 707–717. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Larsson, P.; Bidonde, J.; Olsen, U.; Gay, C.L.; Lerdal, A.; Ursin, M.; Mead, G.E.; Edvardsen, E. Association of post-stroke fatigue with physical activity and physical fitness: A systematic review and meta-analysis. Int. J. Stroke 2023, 18, 1063–1070. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Kokkinos, P.; Faselis, C.; Samuel, I.B.H.; Pittaras, A.; Doumas, M.; Murphy, R.; Heimall, M.S.; Sui, X.; Zhang, J.; Myers, J. Cardiorespiratory fitness and mortality risk across the spectra of age, race, and sex. J. Am. Coll. Cardiol. 2022, 80, 598–609. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Ross, R.; Blair, S.N.; Arena, R.; Church, T.S.; Després, J.P.; Franklin, B.A.; Haskell, W.L.; Kaminsky, L.A.; Levine, B.D.; Lavie, C.J.; et al. Importance of assessing cardiorespiratory fitness in clinical practice: A case for fitness as a clinical vital sign: A scientific statement from the American Heart Association. Circulation 2016, 134, e653–e699. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Shephard, R.J. Maximal oxygen intake and independence in old age. Br. J. Sports Med. 2009, 43, 342–346. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Balady, G.J.; Arena, R.; Sietsema, K.; Myers, J.; Coke, L.; Fletcher, G.F.; Forman, D.; Franklin, B.; Guazzi, M.; Gulati, M.; et al. Clinician’s guide to cardiopulmonary exercise testing in adults: A scientific statement from the American Heart Association. Circulation 2010, 122, 191–225. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Guazzi, M.; Arena, R.; Halle, M.; Piepoli, M.F.; Myers, J.; Lavie, C.J. 2016 focused update: Clinical recommendations for cardiopulmonary exercise testing data assessment in specific patient populations. Circulation 2016, 133, e694–e711. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Baba, R.; Nagashima, M.; Goto, M.; Nagano, Y.; Yokota, M.; Tauchi, N.; Nishibata, K. Oxygen uptake efficiency slope: A new index of cardiorespiratory functional reserve derived from the relation between oxygen uptake and minute ventilation during incremental exercise. J. Am. Coll. Cardiol. 1996, 28, 1567–1572. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Billinger, S.A.; Taylor, J.M.; Quaney, B.M. Cardiopulmonary response to exercise testing in people with chronic stroke: A retrospective study. Stroke Res. Treat. 2012, 2012, 987637. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. van de Port, I.G.L.; Kwakkel, G.; Wittink, H. Systematic review of cardiopulmonary exercise testing post stroke: Are we adhering to practice recommendations? J. Rehabil. Med. 2015, 47, 881–900. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Wittink, H.; Verschuren, O.; Terwee, C.; de Groot, J.; Kwakkel, G.; van de Port, I. Measurement properties of maximal cardiopulmonary exercise tests protocols in persons after stroke: A systematic review. J. Rehabil. Med. 2017, 49, 689–699. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Marzolini, S.; Oh, P.; McIlroy, W.; Brooks, D. The feasibility of cardiopulmonary exercise testing for prescribing exercise to people after stroke. Stroke 2012, 43, 1075–1081. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Moore, S.A.; Jakovljevic, D.G.; Ford, G.A.; Rochester, L.; Trenell, M.I. Exercise induces peripheral muscle but not cardiac adaptations after stroke: A randomized controlled pilot trial. Arch. Phys. Med. Rehabil. 2016, 97, 596–603. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Jang, W.Y.; Kim, W.; Kang, D.O.; Park, Y.; Lee, J.; Choi, J.Y.; Roh, S.Y.; Na, J.O.; Choi, C.U.; Rha, S.W.; et al. Reference values for cardiorespiratory fitness in healthy Koreans. J. Clin. Med. 2019, 8, 2191. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. American College of Sports Medicine. ACSM’s Guidelines for Exercise Testing and Prescription, 12th ed.; Ozemek, C., Ed.; Wolters Kluwer: Philadelphia, PA, USA, 2025. [Google Scholar]
  23. Lee, J.L.; Kim, Y.; Huh, S.; Shin, Y.I.; Ko, S.H. Status and barriers of physical activity and exercise in community-dwelling stroke patients in South Korea: A survey-based study. Healthcare 2024, 12, 697. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. von Elm, E.; Altman, D.G.; Egger, M.; Pocock, S.J.; Gøtzsche, P.C.; Vandenbroucke, J.P. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: Guidelines for reporting observational studies. Lancet 2007, 370, 1453–1457. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Kang, D.; Park, J.; Eun, S.-D. Comparing the effects of multicomponent exercise with or without power training on the cardiorespiratory fitness, physical function, and muscular strength of patients with stroke. J. Sports Med. Phys. Fit. 2022, 62, 722–731. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. World Health Organization Regional Office for the Western Pacific. The Asia-Pacific Perspective: Redefining Obesity and Its Treatment; Health Communications Australia: Sydney, Australia, 2000. [Google Scholar]
  27. WHO Expert Consultation. Appropriate body-mass index for Asian populations and its implications for policy and intervention strategies. Lancet 2004, 363, 157–163. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. McLaughlin, J.E.; King, G.A.; Howley, E.T.; Bassett, D.R., Jr.; Ainsworth, B.E. Validation of the COSMED K4 b2 portable metabolic system. Int. J. Sports Med. 2001, 22, 280–284. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Kuipers, H.; Verstappen, F.T.; Keizer, H.A.; Geurten, P.; van Kranenburg, G. Variability of aerobic performance in the laboratory and its physiologic correlates. Int. J. Sports Med. 1985, 6, 197–201. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. de Souza e Silva, C.G.; Kaminsky, L.A.; Arena, R.; Christle, J.W.; Araújo, C.G.S.; Lima, R.M.; Ashley, E.A.; Myers, J. A reference equation for maximal aerobic power for treadmill and cycle ergometer exercise testing: Analysis from the FRIEND registry. Eur. J. Prev. Cardiol. 2018, 25, 742–750. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  31. Kaminsky, L.A.; Imboden, M.T.; Arena, R.; Myers, J. Reference standards for cardiorespiratory fitness measured with cardiopulmonary exercise testing using cycle ergometry: Data from the Fitness Registry and the Importance of Exercise National Database (FRIEND) Registry. Mayo Clin. Proc. 2017, 92, 228–233. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Sietsema, K.E.; Stringer, W.W.; Sue, D.Y.; Ward, S. Wasserman & Whipp’s Principles of Exercise Testing and Interpretation, 6th ed.; Wolters Kluwer: Philadelphia, PA, USA, 2020. [Google Scholar]
  33. Youden, W.J. Index for rating diagnostic tests. Cancer 1950, 3, 32–35. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Bland, J.M.; Altman, D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1, 307–310. [Google Scholar] [CrossRef] [Scilit]
  35. Koo, T.K.; Li, M.Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 2016, 15, 155–163. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Lee, J.; Stone, A.J. Combined aerobic and resistance training for cardiorespiratory fitness, muscle strength, and walking capacity after stroke: A systematic review and meta-analysis. J. Stroke Cerebrovasc. Dis. 2020, 29, 104498. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Boyne, P.; Billinger, S.A.; Reisman, D.S.; Awosika, O.O.; Buckley, S.; Burson, J.; Carl, D.; DeLange, M.; Doren, S.; Earnest, M.; et al. Optimal intensity and duration of walking rehabilitation in patients with chronic stroke: A randomized clinical trial. JAMA Neurol. 2023, 80, 342–351. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Nindorera, F.; Leveque, C.; Meyer, E.; Balestra, C.; Theunissen, S. Optimizing physical fitness in chronic stroke patients: The impact of exercise training modality and dosage on maximal and sub-maximal fitness—A systematic review and meta-analysis. J. Rehabil. Med. 2025, 57, jrm43359. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Saunders, D.H.; Sanderson, M.; Hayes, S.; Johnson, L.; Kramer, S.; Carter, D.D.; Jarvis, H.; Brazzelli, M.; Mead, G.E. Physical fitness training for stroke patients. Cochrane Database Syst. Rev. 2020, 3, CD003316. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.