Abstract
Hydraulic short-circuit (HSC) operation is an important approach to enhancing the operational flexibility of pumped-storage power plants (PSPPs). However, under this new operating mode, the flow characteristics in the bifurcated pipe deteriorate significantly, posing a threat to the efficiency of the piping system and potentially affecting the inflow conditions for the turbine. In this study, six improved bifurcated pipe models were designed, and their internal flows under pumping, generating, and HSC modes were numerically simulated. Entropy production theory and vortex identification method were employed for flow field analysis. The results show that local modifications confined to the bifurcation are insufficient to simultaneously improve energy characteristics across different modes. In contrast, the bypass pipe enables early flow diversion, weakening the original high-dissipation regions while introducing controllable additional losses. M6 achieves an average energy loss reduction of 47.85% in the mid-to-high flow split ratio range (FSR > 0.3). A strong correlation is observed between vortex suppression and energy loss reduction: the bypass pipe substantially shortens the main vortex length at the inlet section of the generating branch, while simultaneously inducing new shear vortices at the junction; adjustment of its installation position is expected to further shorten their extension, thereby ensuring the normal operation of the turbine. This study provides a new technical pathway for extending the operating range of HSC operation and contributes to enhancing the grid-regulation capability of PSPPs.
1. Introduction
As wind and solar power are integrated into the grid on a large scale, the role of hydropower in grid regulation has become increasingly prominent, making the enhancement of its flexibility a current research focus [1,2,3,4]. Hydraulic short-circuit (HSC) operation, a novel approach to enhancing the operational flexibility of pumped storage power plants, enables the simultaneous operation of pumps and turbines [5]. This strengthens the plants’ capacity to regulate power consumption and improves their frequency regulation support for the grid, garnering widespread attention in recent years [6,7].
The high-pressure bifurcated pipe is a critical flow passage component under hydraulic short-circuit operation. Previous studies have shown that the fluid undergoes sharp turning and wall impingement in the bifurcation region, which can induce intense vortices (e.g., Dean vortices) that significantly deteriorate the local flow patterns [8,9,10,11]. Therefore, this operation mode poses new challenges to the efficient operation of the hydraulic system, making it necessary to carry out geometric improvements to enhance the applicability under complex operating conditions. Regarding bifurcation optimization research, previous studies have provided valuable references:
Huber et al. [12] combined model experiments with numerical simulations to investigate the hydraulic characteristics of a T-junction in the Kops 2 power plant under various operating modes, including generating, pumping, and HSC. They attempted to reduce local head losses and vortex intensity by introducing a relatively smooth transition at the intersection of the main pipe and the branch pipe. This optimization showed only a slight advantage in generating mode, while its hydraulic performance deteriorated in pumping and HSC modes.
Campero et al. [13] further focused on the flow uniformity in T-junctions under HSC mode. By establishing a multi-indicator evaluation system that includes parameters such as axial velocity distribution and root-mean-square (RMS) of velocity fluctuations, they proposed an engineering criterion for the minimum distance between the bifurcation and the turbine spiral casing inlet, aiming to balance the reduction in construction costs with the assurance of stable turbine operation.
Wang et al. [14] proposed a flat-bottomed bifurcation design in which the bottoms of the main pipe, cone pipe, and branch pipes are set at the same elevation to address the ponding issue during maintenance periods. Numerical simulation results show that the internal flow pattern of the new bifurcation remains highly similar to that of the original design, with the increase in head loss being slightly higher but still within an acceptable range; moreover, the overall structure exhibits no significant stress concentration and meets the strength requirements of the relevant specifications.
Radulescu [15] combined experiments with numerical simulations to optimize the geometry of bifurcations in oil pipelines. Using particle image velocimetry (PIV) to observe streamline curvature, parasitic vortices, and flow separation regions, these features were used to inversely modify the bifurcation shape. The optimized bifurcation achieved a 2.1% reduction in local head loss, demonstrating the feasibility of geometry optimization based on flow visualization.
Although the above studies provide valuable guidance for bifurcated pipe optimization, research specifically addressing HSC operation remains relatively limited. This work examines a Y-shaped crescent-rib bifurcated pipe, widely used in hydropower systems. Without significantly affecting conventional pumping and generating modes, the flow and energy characteristics under HSC mode are enhanced by improving the pipe geometry, thereby enhancing its multi-condition applicability and better serving grid regulation needs.
2. Numerical Model and Methodology
2.1. Description of Geometry and Boundaries
The original model is a standard Y-shaped crescent-rib bifurcated pipe, denoted as M0, consisting of a main pipe, two branch pipes, and a bifurcation. The main pipe has a diameter of 5.2 m, and the two branch pipes have diameters of 3.6 m. The bifurcation adopts a common tangent sphere design with a sphere diameter of approximately 6.2 m, within which a crescent rib is embedded as a stiffening beam.
There are six improved models in total, which can be divided into two categories based on the region of adjustment:
- Adjusting the bifurcation region. M1 adopts a smooth transition between the main pipe and branch pipes, rather than the common tangent sphere design; M2 is derived from the original model by removing the crescent rib; M3 enlarges the diameter of the common tangent sphere to 7.9 m. To ensure comparability, none of the three models includes the crescent rib.
- Adding a bypass pipe between the two branch pipes. Based on M0, a 3.6 m diameter bypass pipe is added between the two branch pipes, and the configurations are denoted as M4, M5, and M6 in ascending order of the central angle of the bypass pipe centerline.
Figure 1 presents the original model, along with the key regional features of the six improved models. In addition, arrows of different colors in M0 indicate the flow directions under different operation modes.
Figure 1.
Original and improved bifurcated pipe models.
The computational boundary conditions for the three-dimensional flow field are set according to actual operating modes. A pressure boundary is uniformly applied at the cross-section of the main pipe to satisfy the head requirement of the upper reservoir, with a magnitude of 4.25 MPa. Velocity boundaries are applied at the cross-sections of the two branch pipes to accommodate the adjustment of flow direction and velocity. A no-slip wall boundary condition is adopted for the pipe walls. For HSC mode, the flow split ratio (FSR) is defined to quantify the flow distribution between the different pipelines:
where and denote the flow rates in the generating branch and the pumping branch, respectively, and the flow split ratio is their ratio.
Table 1 presents the boundary conditions for various operating modes and the corresponding FSRs for each HSC operating point.
Table 1.
Bifurcated pipe operation modes and corresponding boundary conditions.
2.2. Theory and Methods
2.2.1. Governing Equations and Turbulence Model
Given the incompressibility of water, the governing equations for mass and momentum conservation within the pipeline system are as follows:
In this study, numerical simulations of various bifurcated pipe models were conducted using ANSYS Fluent 2022R1 software. The Reynolds-Averaged Navier–Stokes (RANS) equations were solved using the SST k-ω model, selected for its capability to capture complex flow features, including rotating shear flows, boundary layer flows with significant adverse pressure gradients, and secondary flows [16]. The governing equations are as follows [17]:
where is fluid density; is turbulence kinetic energy per unit mass; is the specific kinetic energy dissipation rate; is time; ( = 1, 2, 3) is coordinate component; ( = 1, 2, 3) is fluid velocity component; is dynamic viscosity; is the eddy viscosity coefficient; is the turbulent kinetic energy production term, defined as , which prevents the over-prediction of turbulence in stagnation regions; is a blending function, used to achieve a smooth transition between the near-wall region ( model) and the far-field region ( model); and the remaining parameters are model constants.
2.2.2. Entropy Production Theory
The entropy production theory is widely applied in evaluating energy losses in hydraulic machinery [18,19]. Compared to indicators such as pressure drop and efficiency, the entropy production rate clearly reveals the distribution of local losses. Based on their specific physical meanings, the entropy production rate can be categorized into the direct dissipation term (EPDD), turbulent dissipation term (EPTD), and wall shear term (EPWS), with the expressions given as follows [20,21,22]:
where denotes EPDD, denotes EPTD, denotes EPWS, is the temperature 298.15 K, is the effective dynamic viscosity of fluid, which combines turbulent viscosity and dynamic viscosity , denotes the wall shear stress, denotes the velocity at the centroid of the first near-wall grid layer.
Based on the findings of Xia et al. [11], the turbulent dissipation term dominates the flow losses in the bifurcated pipe and serves as a key indicator for evaluating local losses in the piping system. However, since the fluctuating velocity cannot be measured directly, the turbulent dissipation term is typically approximated using the turbulence kinetic energy per unit mass k, and the specific dissipation rate ω. The formula can be expressed as (with = 0.09) [23]:
2.2.3. Energy Loss Rate
We define the concept of energy loss rate to characterize the energy loss within the pipeline system under different operating modes. The energy at a specified cross-section is represented by the product of total pressure and flow rate, and the content of the formula is adjusted according to the specific operating modes. A generalized formula can be expressed as:
where the energy loss rate (ELR) represents the ratio of energy lost to the total input energy, denotes the total energy input, and denotes the total energy output.
2.3. Grid Independence and Turbulence Model Comparison
Grid independence verification was conducted based on the original model M0. Boundary layer refinement was applied to the near-wall regions across the entire flow domain, and refinement was also implemented in the complex bifurcation mainstream region. Using the energy loss rates under typical HSC (FSR ≈ 0.5), pumping, and generating conditions as evaluation criteria, six grid models were generated, and the final grid number for M0 was determined to be 2.38 million. The grid independence verification results are shown in Figure 2.
Figure 2.
Grid independence verification (data from [11]).
The same grid strategy was applied to models M1–M3, resulting in grid numbers of 2.29 million, 2.36 million, and 3.09 million, respectively. Considering the significant change in flow topology for the models with an added bypass pipe, local refinement was further extended to the bypass pipe. The grid numbers for models M4–M6 are 3.70 million, 3.91 million, and 3.98 million, respectively. Here, model M6 is taken as a representative to show the grid details, as presented in Figure 3.
Figure 3.
Grid details (M6 model as an example).
To enhance the confidence in the numerical results in the absence of experimental validation, three widely used models (SST k-ω, RNG k-ε, and Realizable k-ε) were selected to simulate various operating points under the HSC mode, with all other parameters kept strictly identical. Figure 4 presents the computed ELR curves and their relative standard deviations (RSD). Except for a few operating points (e.g., at FSR = 0.37), the three sets of ELR curves exhibit good consistency (RSD < 10%). The results from the more universally applicable SST k-ω model were adopted for subsequent analyses.
Figure 4.
Turbulence model comparison.
3. Results
3.1. Pumping and Generating Modes
Figure 5 and Figure 6 respectively show the internal flow patterns and EPTD contours of the seven models under pumping and generating modes. For the pumping mode, the loss of M0 mainly originates from the impingement of the incoming flows from the two branch pipes at the bifurcation, forming strong vortices and inducing energy dissipation. The remaining six models exhibit similar flow and loss characteristics in this region as well. For M4–M6, additional energy dissipation occurs at the junctions between the bypass pipe and the branch pipes, and this dissipation becomes increasingly pronounced as the bending degree of the bypass pipe increases.
Figure 5.
(a) Flow patterns and (b) EPTD distributions in different bifurcated pipe models under pumping mode.
Figure 6.
(a) Flow patterns and (b) EPTD distributions in different bifurcated pipe models under generating mode.
For the generating mode, the loss of M0 mainly originates from the energy dissipation caused by flow separation on both sides of the rib and around the outer wall of the pipe in the bifurcation. For M1–M3, due to the removal of the crescent rib, flow separation and energy loss occur only around the outer pipe wall, and the loss level tends to increase with the size of the bifurcation. For M4–M6, the main differences still lie in the junctions between the bypass pipe and the branch pipes; however, compared with the pumping mode, the energy dissipation in this region is significantly weakened.
Figure 7 further presents the energy loss rates of the seven models under pumping and generating modes, where the energy loss rates of M0 under both modes (indicated by dashed lines) serve as the reference baseline.
Figure 7.
Energy loss rate for different bifurcated pipe models under pumping and generating modes.
M1 improves the energy characteristics under generating mode, while its energy loss increases under pumping mode. The reason is that the direct smooth transition between the main pipe and the branch pipes effectively ensures well-attached flow, thereby reducing the energy dissipation caused by flow separation under generating mode. However, under pumping mode, due to the lack of buffering effect from the spherical cavity, the flow converges directly in a smaller space, resulting in stronger shear interaction between the two high-velocity streams, which consequently leads to higher energy dissipation.
M2 is the closest to M0 in terms of model configuration, with the smallest change in loss. The slight decrease in energy loss under generating mode is attributed to the elimination of flow separation near the rib.
M3 exhibits the most significant increase in energy loss under pumping mode, with a rise exceeding 60%. The reason lies in that the sudden expansion and sudden contraction caused by the excessively large spherical cavity induce complex flows such as strong secondary flows. These additional flow structures couple with the original impinging flow, further aggravating flow disorder and thus leading to higher energy dissipation. For the generating mode, although similar effects exist, the flow tends to separate rather than impinge, resulting in lower vortex intensities, and therefore the change in energy loss remains insignificant.
For M4–M6, the flow from the two branch pipes inevitably enters the bypass pipe, where it turns and impinges at the junctions, inducing flow separation and thus leading to additional energy loss. This loss characteristic is more pronounced under pumping mode, due to the smaller angle between the bypass pipe inlet and the branch inflow, which more readily induces flow into the bypass pipe. Compared with M0, the maximum increase in energy loss is kept within 17.38% under pumping mode and 12.54% under generating mode. Overall, the rise in energy loss remains relatively modest.
3.2. HSC Mode
The reduction in energy losses within the bifurcated pipe directly decreases the pressure drop in the piping system. Under the same upstream and downstream water levels, this translates to an increase in available head, or equivalently, a reduced flow demand for the same turbine power output. Under HSC mode, this relationship is of particular importance. Based on a combined consideration of turbine operational performance and the overall regulation capability of the hydraulic system, the flow split ratio can be divided into three ranges: high, medium, and low. Typical operating conditions from each range are selected for analysis.
3.2.1. High Flow Split Ratio Range (0.7 < FSR < 1.0)
In this FSR range, most of the water from the pump flows into the turbine, enabling the turbine to operate in an efficient range, but the overall input power regulation range of the system is relatively limited. The following analysis takes the case with FSR = 0.85 as an example.
Figure 8 presents the flow patterns and EPTD contours of the seven models at FSR = 0.85. As shown in Figure 8b, the high dissipation region of M0 is mainly located at the inlet section from the bifurcation to the generating branch, with a small portion near the wall of the main pipe. Under this operating condition, most of the fluid experiences flow around rib, impingement, and turning, forming strong vortices that induce high-intensity viscous dissipation. A small amount of fluid flows along the wall into the main pipe, shearing with the stagnant water and causing additional energy loss.
Figure 8.
(a) Flow patterns and (b) EPTD distributions in different bifurcated pipe models under HSC mode (FSR = 0.85).
The energy loss regions of M1–M3 are generally similar to those of M0, but with some differences. For M2, the removal of the rib eliminates the flow-around effect, reducing the vortex intensity in the generating branch and improving the flow. However, the absence of the rib also weakens the guiding effect, aggravating the flow disorder into the main pipe and increasing the loss. M1 adopts a smooth transitional connection, which weakens the sudden expansion effect as the flow passes from the pumping branch to the bifurcation, and indirectly provides a guiding effect on the flow entering the main pipe. Meanwhile, the wall-attached turning of the flow in a smaller space also suppresses the vortex development within the generating branch, thereby reducing energy loss in both pipes. M3 adopts a larger spherical cavity design, reducing the velocity in the most severely deteriorated flow region and thereby also helping to mitigate energy dissipation.
For M4–M6, the early diversion through the bypass pipe significantly reduces the flow velocity and vortex intensity in the bifurcation, and markedly shrinks the high dissipation region. However, this also introduces additional losses caused by flow separation at the bypass pipe and its junctions. Reducing the angle between the incoming flows from the two branch pipes and the bypass pipe is the key to suppressing flow separation losses; therefore, the high dissipation regions from M4 to M6 show a decreasing trend. For M6, only a small high dissipation region is distributed at the inlet section of the bypass pipe, and the overall energy dissipation of the piping system remains at a relatively low level.
3.2.2. Medium Flow Split Ratio Range (0.3 < FSR < 0.7)
In this FSR range, the flow rates to the turbine and the upper reservoir are comparable, balancing efficient turbine operation and favorable input power regulation. The case with FSR ≈ 0.50 is analyzed below.
Figure 9 presents the flow patterns and EPTD contours of the seven models at FSR = 0.49. Compared with the FSR = 0.85 case, the locations of the high dissipation regions of M0 at this operating condition are generally consistent. The main differences lie in that the high dissipation region on the generating branch side is noticeably reduced, while that on the main pipe side extends further downstream. Overall, the energy loss mechanisms in the two regions do not change significantly; the differences are primarily reflected in the variation in energy loss intensity caused by the change in flow rate.
Figure 9.
(a) Flow patterns and (b) EPTD distributions in different bifurcated pipe models under HSC mode (FSR = 0.49).
For M1–M3, the analysis follows a similar rationale to that for the FSR = 0.85 case. However, for M4, there is no visible flow activity inside the bypass pipe, indicating that its flow-diversion effect has become negligible. Consequently, the high dissipation region at the inlet section of the generating branch remains almost unchanged compared with M0. Meanwhile, additional energy dissipation due to flow shear exists at the junctions between the bypass pipe and the two branch pipes. For M5 and M6, the bypass pipe still performs the flow diversion function, and the latter exhibits better diversion effectiveness, resulting in a notable reduction in the high dissipation region at the inlet of the generating branch.
3.2.3. Low Flow Split Ratio Range (0 < FSR < 0.3)
In this FSR range, most of the water from the pump enters the upper reservoir, with only a small portion flowing to the turbine. At this condition, the overall input power regulation level is relatively high, but the turbine faces safety risks such as vibration and cavitation. The threshold FSR = 0.3 represents the current technical limit of wide-load operation retrofits, while the range below 0.3 is a regime that requires further extension of low-load capability. The following analysis takes the case with FSR = 0.12 as an example.
Figure 10 presents the flow patterns and EPTD contours of the seven models at FSR = 0.12. As shown in Figure 10b, the high dissipation region of M0 is mainly located at the inlet section from the bifurcation to the main pipe. Under this operating condition, most of the fluid experiences impingement and turning, generating strong secondary flows and thereby causing high-intensity energy dissipation in the main pipe region. Due to the low flow rate in the generating branch, its energy dissipation characteristics are not prominent.
Figure 10.
(a) Flow patterns and (b) EPTD distributions in different bifurcated pipe models under HSC mode (FSR = 0.12).
The high dissipation regions of M1–M3 similarly shift to the main pipe side, though their distribution patterns differ. The removal of the rib in M2 weakens the flow guidance, leading to increased flow disorder and greater loss in the main pipe. In M1, the absence of a spherical cavity design forces the flow to turn within a smaller space, resulting in more pronounced velocity gradients (Figure 10a) and a more concentrated high dissipation region. M3 benefits from the buffering effect of a larger spherical cavity, which reduces velocity differences within the deteriorated flow region and weakens fluid shear, as reflected by lower EPTD magnitudes. However, the sudden expansion–sudden contraction geometry induces more complex vortices, extending the overall range of the dissipation region.
For M4–M6, the high dissipation regions are located in the main pipe side and at the junction between the bypass pipe and the generating branch. Of particular note is that for M4 and M5, the flow direction in the bypass pipe is opposite to the design intent (from the generating branch to the pumping branch), leading to increased flow velocity in the pumping branch. The resulting strong shear interaction between the reverse flow and the mainstream induces high energy dissipation along the inner wall of the pumping branch. For M6, the bypass pipe functions as intended for flow diversion, thereby reducing the flow velocity at the bifurcation and shrinking the high dissipation region.
3.2.4. Summary of HSC Mode Results
As the FSR decreases, the primary energy dissipation regions of M1–M3 all exhibit a shift from the generating branch toward the main pipe, with more severe energy losses in the generating branch at high FSR range. M1 limits the vortex development in the bifurcation through a smooth transitional connection, thereby primarily improving the energy loss in the generating branch. M2 reduces the flow-around effect into the generating branch by removing the rib, but this also weakens the flow guidance into the main pipe. M3 reduces the flow velocity in the deteriorated flow region by enlarging the spherical cavity, but simultaneously induces more complex vortex structures in the main pipe.
The distribution of high dissipation regions for M4–M6 follows a similar trend with FSR as that of M1–M3, but with two main differences: (1) at high FSR range, energy loss in the generating branch is significantly reduced; and (2) additional energy loss is introduced within the bypass pipe and at its junctions with the branch pipes. The bypass pipe is more effective at high FSR range, whereas its performance deteriorates at low FSR range; increasing the bending degree of the bypass pipe can enhance its applicability over a wider range of FSR.
Figure 11 further presents the energy loss rate curves of the seven models under HSC mode as FSR varies, with the curve of M0 shown as a black solid line serving as the reference baseline.
Figure 11.
Energy loss rate for different bifurcated pipe models under HSC mode.
For M1, when FSR > 0.3, the ELRs show a significant improvement, with an average reduction of 35.95%; whereas at FSR < 0.3, the ELRs increase by 14.05%.
M2 exhibits an improvement only at FSR = 1, with a reduction of 23.44%; at most other operating points, the ELRs show an increase compared with M0, averaging 10.54%.
The optimization effect of M3 is demarcated at FSR ≈ 0.5: above this value, ELRs decrease by 31.70% on average; below it, they deteriorate substantially, increasing by 63.04%.
For both M4 and M5, the ELR curves show improvement at FSR > 0.5, with M5 achieving a greater reduction (52.02%) than M4 (32.81%); at FSR < 0.5, the two curves are quite close, and both experience increased energy losses of 21.52% and 15.70%, respectively.
Most notably, M6 exhibits only a slight increase in energy loss at FSR < 0.3 (with an average rise of 6.02%), while achieving an average reduction of 47.85% when FSR > 0.3, with the reduction becoming more pronounced at higher FSR values and peaking at 76.15% at FSR = 1. Moreover, the ELR curve of M6 remains generally flat without significant fluctuations, indicating that this model maintains favorable energy performance across the full FSR range, with relatively low energy losses even under low-FSR conditions.
4. Discussion
4.1. Bypass Pipe Diversion Characteristics
The flow rates in the bypass pipes of M4–M6 under HSC mode are extracted, with the direction from the pumping branch to the generating branch defined as positive and the reverse as negative. The ratios of the bypass flow rate (Qbp) to the inlet flow rate of the pumping branch (Qpb) are plotted versus FSR, as shown in Figure 12.
Figure 12.
Bypass pipe flow-diversion performance for M4–M6 under HSC mode.
The three curves in Figure 12 exhibit generally consistent trends. As the FSR decreases, the flow-diversion performance of the bypass pipe gradually weakens for all models. When FSR drops below 0.4, reverse flow occurs in the bypass pipes of M4 and M5, contrary to the design intent. This reverse flow is primarily attributed to the increasing velocity difference between the two branch pipes at lower FSR. The generating branch—with lower flow rate—exhibits a higher static pressure, while the pumping branch maintains a lower static pressure due to higher velocity. The resulting pressure differential drives the reverse flow. Moreover, a more curved bypass pipe offers greater flow resistance. This also explains why almost no reverse flow occurs in M6.
Among the three models, M6 demonstrates the best diversion performance: in the high FSR range above 0.7, the bypass flow ratio remains above 40%, reaching a maximum of 63.6%. However, even for M6, additional energy loss inevitably occurs in the low FSR range as well as under pumping and generating modes. If valves are installed at the junctions between the bypass pipe and the two branch pipes, the on/off status of the bypass pipe can be controlled according to the actual operating conditions, thereby extending its applicability to a wider range.
4.2. Energy Improvement Characteristics
M6 exhibits better performance in both flow diversion and energy characteristics compared to M4 and M5. To further validate the energy improvement achieved by the bypass pipe, this section presents a comparative analysis of energy loss variations between M6 and M0 in key flow regions.
Based on the preceding analysis, the primary loss regions of the original bifurcated pipe M0 under HSC mode are concentrated in the inlet section of the generating branch and the main pipe, denoted as R1 and R2, respectively. The remaining low-dissipation regions are collectively designated as R3. With the introduction of the bypass pipe, additional energy dissipation occurs within the bypass pipe itself and at its junctions with the two branch pipes, denoted as R4. The distribution of these regions is illustrated in Figure 13.
Figure 13.
Loss region distribution in the bifurcated pipe under HSC mode.
By integrating the entropy production rate of the turbulent dissipation term (EPTD) over each region, the composition of energy losses in each region is obtained, as presented in Figure 14. For M0, the total loss increases with rising FSR, particularly beyond FSR = 0.49; for M6, the total loss first increases and then decreases, reaching its minimum at FSR = 0.85. These trends are consistent with the ELR curves, also confirming the validity of using EPTD alone to characterize the overall energy loss.
Figure 14.
Comparison of regional energy losses between M0 and M6 at FSR = 0.12, 0.49, and 0.85.
From the perspective of regional contributions, for M0, as FSR increases, the loss proportion of R1 continues to rise while that of R2 decreases, indicating a migration of the primary dissipation region from the main pipe to the generating branch. For M6, the early flow diversion through the bypass pipe effectively reduces the high-intensity dissipation in R1 and R2, but simultaneously introduces additional losses in R4. Notably, at FSR = 0.85, although the loss proportion of R4 reaches 43.4%, the substantial reduction in R1 and R2 still leads to the lowest total loss. These results confirm that the bypass pipe plays an important role in improving the energy characteristics under HSC mode, particularly at higher FSR.
4.3. Vortex Within the Generating Branch
Under HSC mode, the unstable vortices induced within the generating branch may extend to the turbine inlet and affect the inflow conditions. Shortening this extension helps reduce the risk of vibration and fatigue caused by non-uniform inflow, thereby indirectly supporting the safe operation of the turbine. This section analyzes the vortex evolution within this branch for both the original and six improved models.
Figure 15a presents the vortex evolution within the generating branch of M0 under HSC mode with varying FSR; Figure 15b further quantifies the variation in the ratio of vortex length to generating branch length with FSR. It should be noted that the vortex length is measured based on the main vortex structures with well-defined morphology in the mainstream region, in order to accurately characterize the actual extent of vortex extension toward the downstream of the branch. The results show that the vortex length increases continuously with rising FSR, reaching the branch outlet at FSR = 0.85, which may affect the normal operation of the turbine.
Figure 15.
Vortex lengths within the generating branch of M0 versus FSR. (a) Vortices identified by the Q-criterion (Q = 2). (b) Lv: vortex length; Lgb: length of the generating branch (from bifurcation center to branch outlet).
The operating point with the longest vortex length (FSR = 0.85) is selected to further compare the vortex morphology and statistical length within the generating branch across the seven models, as shown in Figure 16.
Figure 16.
(a) Vortices identified by the Q-criterion (Q = 2) within the generating branch of M0–M6 (HSC, FSR = 0.85). (b) Ratio of vortex length to generating branch length.
For M1–M3, the vortex morphology generally corresponds to the distribution of energy losses. Under this condition, the high-dissipation region is primarily concentrated in the generating branch. Both M1 and M3 exhibit reduced energy losses, indicating improved flow conditions in the generating branch, with vortex lengths of 0.62 and 0.73 times the branch length, respectively. Among them, M1 achieves better energy improvement, accompanied by a shorter vortex length. In contrast, M2 shows higher energy losses than M0 near this operating point, with the vortex still extending to the branch outlet and exhibiting a larger spatial scale.
For M4–M6, the vortices originate mainly from two sources. One is located at the inlet section of the generating branch, where the bypass flow diversion significantly reduces energy losses in this region, and the vortex length is markedly shorter than that of M0–M3 (refer to the black dashed line in Figure 16a), with this trend becoming more pronounced as the curvature of the bypass pipe increases. The other source is at the junction between the bypass pipe and the generating branch, caused by shear effects from the converging flows. The vortex lengths in this region show minor differences among the three models, extending to 0.69, 0.79, and 0.76 times the branch length, respectively. Among them, M4 exhibits a slightly shorter vortex extension but a larger spatial scale, primarily due to a stronger impingement shear in the vertical direction. Since these vortices originate from the junction region, adjusting the bypass pipe installation position is expected to further shorten their extension.
5. Conclusions
This study focuses on the widely used Y-shaped crescent-rib bifurcated pipe in PSPPs. Based on the original configuration, six improved models were designed, and their internal flow under pumping, generating, and HSC modes was numerically simulated. Combined with entropy production theory and vortex identification method, the energy loss characteristics and vortex evolution within the piping system were systematically analyzed. The main conclusions are as follows:
- Modifications confined solely to the common tangent sphere size and the presence of the rib are insufficient to simultaneously improve energy characteristics across different modes. Under pumping and generating modes, none of the three models significantly reduces energy loss, with M3 even increasing by over 60% during pumping. Under HSC mode, only M1 shows improvement—35.95% average reduction for FSR > 0.3, but a 14.05% increase for FSR < 0.3. M2 exhibits virtually no improvement, while M3 shows a notable reduction for FSR > 0.5, but surges by 63.04% for FSR < 0.5.
- The addition of a bypass pipe effectively improves the energy characteristics under HSC operation, with its effectiveness highly dependent on the FSR range and the curvature of the bypass pipe. Through early flow diversion, the bypass pipe reduces the original high-dissipation regions, while introducing controllable additional losses within the bypass pipe and at its junctions. M6 exhibits the best energy performance, as reflected by its flat ELR curve—reducing losses by 47.85% on average for FSR > 0.3, while increasing by only 6.02% for FSR < 0.3. The adaptability under multiple operating conditions can be further enhanced by installing valves.
- The vortex length within the generating branch generally increases with rising FSR, reaching the outlet at FSR = 0.85. A strong correlation is observed between flow improvement and energy loss reduction: M1 and M3 exhibit reduced losses with vortex lengths shortened to 0.62 and 0.73 times the branch length, while M2 shows increased losses without effective vortex suppression. The introduction of the bypass pipe substantially shortens the main vortex at the inlet section of the generating branch, while simultaneously inducing new shear vortices at the junction; adjustment of its installation position is expected to further shorten vortex extension.
The bifurcation modifications and bypass pipe scheme proposed in this study are currently at a conceptual design stage. The primary objective is to verify the feasibility of improving the flow and energy characteristics of the bifurcated pipe under HSC operation, thereby providing a reference for future piping designs. The potential impacts of the additional piping and possible valves on structural design, hydraulic transients, and overall plant efficiency require further research and evaluation.
Author Contributions
S.Z.: Conceptualization; Data curation; Formal analysis; Methodology; Software; Writing—original draft. M.X.: Conceptualization; Data curation; Formal analysis; Methodology; Software; Writing—review and editing. S.L.: Funding acquisition; Project administration; Supervision. F.J.: Funding acquisition; Project administration; Supervision. J.Y.: Conceptualization; Project administration; Resources; Supervision; Writing—review and editing. Z.W.: Conceptualization; Resources; Supervision; Writing—review and editing. All authors have read and agreed to the published version of the manuscript.
Funding
This study was supported by the scientific research project of China Yangtze Power Co., Ltd. (project number: 3423020004).
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.
Conflicts of Interest
Shang Zhu, Ming Xia, Shizhe Liu, Fangxu Ji and Jing Yang were employed by the company China Three Gorges Corporation. The authors declare that this study received funding from China Yangtze Power Co., Ltd. The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article or the decision to submit it for publication.
References
- Joshi, P.; Rao, A.B.; Banerjee, R. Review of Solar PV Deployment Trends, Policy Instruments, and Growth Projections in China, the United States, and India. Renew. Sustain. Energy Rev. 2025, 213, 115436. [Google Scholar] [CrossRef] [Scilit]
- Koondhar, M.A.; Albasha, L.; Mahmoud, S.A.; Amin, L.G.; Mahariq, I. Comparative Analysis of Onshore, Offshore, and Floating Wind Turbines for Renewable Energy Systems: A Review. Ocean Eng. 2026, 343, 123243. [Google Scholar] [CrossRef] [Scilit]
- Jiang, J.; Ming, B.; Liu, P.; Huang, Q.; Guo, Y.; Chang, J.; Zhang, W. Refining Long-Term Operation of Large Hydro–Photovoltaic–Wind Hybrid Systems by Nesting Response Functions. Renew. Energy 2023, 204, 359–371. [Google Scholar] [CrossRef] [Scilit]
- Lin, M.; Shen, J.; Cheng, C.; Lü, Q.; Wang, Y. Long-Term Multi-Objective Optimal Scheduling for Large Cascaded Hydro-Wind-Photovoltaic Complementary Systems Considering Short-Term Peak-Shaving Demands. Energy Convers. Manag. 2024, 301, 118063. [Google Scholar] [CrossRef] [Scilit]
- Landry, C.; Nicolet, C.; Badina, C.; Pichon, H.; Drommi, J.-L. Contribution for the Roadmap of Hydraulic Short Circuit Implementation: Case of Grand-Maison Pumped Storage Power Plant. IOP Conf. Ser. Earth Environ. Sci. 2022, 1079, 012107. [Google Scholar] [CrossRef] [Scilit]
- Cui, Z.; Guo, W. Coordinated Operation of Grid-Connected Hybrid System Composed of Pumped Storage and Wind under Hydraulic Short Circuit Operation Mode. Energy 2026, 342, 139638. [Google Scholar] [CrossRef] [Scilit]
- Cui, Z.; Guo, W. Hydraulic Superposition of Hybrid Pumped Storage System Considering Successive Load Rejections under Generation and Hydraulic Short Circuit. Renew. Energy 2025, 240, 122206. [Google Scholar] [CrossRef] [Scilit]
- Decaix, J.; Mettille, M.; Drommi, J.-L.; Hugo, N.; Münch-Alligné, C. Computation Fluid Dynamics Investigation of the Flow in Junctions: Application to Hydraulic Short Circuit Operating Mode. LHB 2023, 109, 2290025. [Google Scholar] [CrossRef] [Scilit]
- Decaix, J.; Mettille, M.; Hugo, N.; Valluy, B.; Münch-Alligné, C. CFD Investigation of the Hydraulic Short-Circuit Mode in the FMHL/FMHL+ Pumped Storage Power Plant. Energies 2024, 17, 473. [Google Scholar] [CrossRef] [Scilit]
- Morabito, A.; Vagnoni, E. CFD-Based Analysis of Pumped Storage Power Plants Implementing Hydraulic Short Circuit Operations. Appl. Energy 2024, 369, 123474. [Google Scholar] [CrossRef] [Scilit]
- Xia, M.; Zhu, S.; Ding, W.; Kang, Z.; Yang, J.; Wang, Z. Analysis of Flow and Structural Characteristics of Y-Shaped Bifurcated Pipe with Crescent Rib Under Hydraulic Short-Circuit Mode. Water 2026, 18, 1304. [Google Scholar] [CrossRef] [Scilit]
- Huber, B.; Korger, H.; Fuchs, K. Hydraulic Optimization of a T-Junction-Hydraulic Model Tests and CFD-Simulation. In Proceedings of the 31st IAHR World Congress, Seoul, Republic of Korea, 11–16 September 2005. [Google Scholar]
- Campero, P.; Beck, J.; Jung, A. Analysis of the Flow at a T-Bifurcation for a Ternary Unit. IOP Conf. Ser. Earth Environ. Sci. 2014, 22, 042013. [Google Scholar] [CrossRef] [Scilit]
- Wang, Y.; Shi, C.; Wu, H.; Zhang, Q.; Su, K. Flat-Bottomed Design Philosophy of Y-Typed Bifurcations in Hydropower Stations. Struct. Eng. Mech. 2016, 57, 1085–1105. [Google Scholar] [CrossRef] [Scilit]
- Radulescu, V. Experimental and Numerical Modeling of Viscous Fluid Flow in Bifurcated Long Pipes for Oil Transport. In Proceedings of the Volume 1: Fluid Applications and Systems; Fluid Measurement and Instrumentation, Virtual, Online, 13–15 July 2020; American Society of Mechanical Engineers: New York, NY, USA, 2020; p. V001T01A024. [Google Scholar]
- Jin, F.; Luo, Y.; Zhao, Q.; Cao, J.; Wang, Z. Energy Loss Analysis of Transition Simulation for a Prototype Reversible Pump Turbine during Load Rejection Process. Energy 2023, 284, 129216. [Google Scholar] [CrossRef] [Scilit]
- Menter, F.R. Two-Equation Eddy-Viscosity Turbulence Models for Engineering Applications. AIAA J. 1994, 32, 1598–1605. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhou, L.; Hang, J.; Bai, L.; Krzemianowski, Z.; El-Emam, M.A.; Yasser, E.; Agarwal, R. Application of Entropy Production Theory for Energy Losses and Other Investigation in Pumps and Turbines: A Review. Appl. Energy 2022, 318, 119211. [Google Scholar] [CrossRef] [Scilit]
- Pu, W.; Wang, X.; Wang, W.; Ji, L.; Li, W.; Agarwal, R. A Review of Research on Hydro-Turbine Energy Loss Based on Entropy Generation Theory. Flow Meas. Instrum. 2026, 111, 103407. [Google Scholar] [CrossRef] [Scilit]
- Herwig, H.; Kock, F. Direct and Indirect Methods of Calculating Entropy Generation Rates in Turbulent Convective Heat Transfer Problems. Heat Mass Transf. 2006, 43, 207–215. [Google Scholar] [CrossRef] [Scilit]
- Schmandt, B.; Herwig, H. Internal Flow Losses: A Fresh Look at Old Concepts. J. Fluids Eng. 2011, 133, 051201. [Google Scholar] [CrossRef] [Scilit]
- Ji, L.; Li, W.; Shi, W.; Tian, F.; Agarwal, R. Effect of Blade Thickness on Rotating Stall of Mixed-Flow Pump Using Entropy Generation Analysis. Energy 2021, 236, 121381. [Google Scholar] [CrossRef] [Scilit]
- Zhou, J.; Xu, L.; Zhang, Y.; Zheng, Y.; Li, C.; Zang, W.; Zhang, Z. Analysis of Vortex Evolution in the Stall Region of Pump-Turbines in Pump Mode: Based on Model Testing and CFD. Renew. Energy 2026, 256, 124410. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.