Abstract
This paper proposes a novel axially parallel salient pole hybrid excitation synchronous generator (PSPHESG) for small and medium hydropower (SMHP). To prevent irreversible demagnetization of the permanent magnets (PMs), while improving the power density and reducing the volume compared with those of a conventional electrically excited synchronous generator equipped with an AC exciter, a salient pole series hybrid excitation machine is axially integrated with an electrically excited machine, with the latter serving as the power compensation section. The basic structure and operating principles of the proposed PSPHESG are introduced. Finite-element analysis (FEA) is used to investigate the magnetic field distribution and no-load characteristics. Moreover, the phase angle deviation characteristics and output performances under load are analyzed, showing favorable voltage output capability over a wide load range during steady-state operation. Finally, the anti-demagnetization capability of the PM is studied under field forcing (FF) and de-excitation (DE). The results confirm that the PSPHESG not only provides good constant-voltage capability but also effectively avoids irreversible PM demagnetization during FF and DE, indicating its promising applicability to SMHP systems.
1. Introduction
The global transition toward renewable energy and distributed power systems has accelerated the deployment of small and medium hydropower (SMHP). This trend has expanded the application scale of hydrogenerators. Meanwhile, increasingly stringent requirements for grid-connection stability and economic performance have created a pressing need for generating equipment with good voltage-regulation capability, high power density, and compact structure [1,2,3,4].
At present, hydrogenerators are dominated by electrically excited synchronous generators (EESGs) with salient-pole rotors. By using continuously adjustable field current, EESGs can flexibly control the air-gap magnetic field and provide a wide voltage-regulation range. However, such generators generally require an additional AC exciter and a rotating rectifier, and they suffer from considerable excitation loss. These features lead to large volume, low power density, and reduced output efficiency, increasing system complexity and compromising the reliability of the generating system [5,6,7]. By contrast, permanent magnet synchronous generators (PMSGs) employ high-performance rare-earth permanent magnets (PMs), enabling higher power density, higher efficiency, and a more compact structure [8,9]. Nevertheless, because the air-gap magnetic field produced by PMs is essentially fixed, a full-power converter is required to regulate the output voltage, which increases the system cost [10]. The difficulty of regulating the air gap magnetic field therefore limits the application of high-performance PMSGs in SMHP.
Hybrid excitation synchronous generators (HESGs) provide a direct route to this compromise by combining a PM with a controllable wound-field source [11,12,13,14]. For hydropower generators, the key issue is not only whether the output voltage can be adjusted, but also how the two excitation sources share the main flux path, excitation loss, thermal burden, and fault-duty requirements. Existing HESG topologies can therefore be understood from the viewpoint of magnetic coupling between the PMs and field windings (FWs), which are summarized as follows.
(1) When the PMs and FWs excitations are coupled through a common main magnetic path, as shown in Figure 1a, the rotor can be made compact and the available space can be used efficiently. This configuration is particularly attractive for salient-pole machines because PMs and FWs can be placed within the rotor pole region. However, the electrically excited flux is forced through the PMs, resulting in limited flux-regulation efficiency and increased risk of irreversible PM demagnetization [15,16,17].
Figure 1.
Equivalent magnetic circuit models of different structures. (a) Series magnetic circuit. (b) Parallel magnetic circuit. (c) Structural parallel. , —magnetomotive forces (MMF) of PM and FW; —armature winding flux linkage; , —magnetic fluxes produced by PM and FW; and , , , , —magnetic reluctances of the PM, FW, rotor, air gap, and stator.
(2) An alternative strategy is to provide an auxiliary flux path for the FWs, as shown in Figure 1b. By diverting the excitation flux away from the PMs, this topology can reduce the excitation burden imposed on the PMs and improve demagnetization robustness. However, the benefit is obtained at the expense of additional bypass iron, flux barriers, and leakage paths. As a result, the machine tends to be more structurally complex and bulky, while its manufacturing and assembly costs also increase [18,19,20].
(3) Structure-parallel HESGs, as represented in Figure 1c, separate the PMs and FWs completely while connecting the armature windings of the two parts in series. Such an arrangement is favorable for output voltage synthesis because the two parts can contribute independently to the terminal voltage. Nevertheless, the improved magnetic decoupling is usually accompanied by a longer axial stack length [21,22,23,24].
Therefore, the structure-parallel HESGs generally offer superior flux regulation capability to series magnetic circuit HESGs while maintaining a simpler structure than that of parallel magnetic circuit HESGs. The axially parallel machines reported in [21,22] combined PM machine with doubly salient machine (DSM) design to achieve bidirectional field control through independent excitation paths. Although this concept improves controllability, the relatively low torque density of the DSM at hydropower speed requires a larger radial size to satisfy the power demand. A radially integrated topology combining PM machine and flux modulation machine design was reported in [25], offering improved structural compactness and reduced weight. However, the introduced gearbox brings additional maintenance requirements, which are undesirable for unattended or long-cycle hydropower operation. In summary, generators for SMHP must provide field forcing (FF) and de-excitation (DE) under fault conditions, as well as long-term operating stability, and existing HESGs remain inadequate in regards to both structure and performance.
A series-connected HESG for automotive applications was proposed in [26], in which PMs embedded in the pole shoes of the salient-pole rotor and FWs wound around the pole bodies jointly regulate the magnetic field, improving rotor utilization and power density, providing the design concept for the present work. In order to fully combine the advantages of the above machine structures, and considering that the risk of PM demagnetization in series flux path HESGs is more prominent in SMHP, this paper proposes a novel axially parallel salient pole hybrid excitation synchronous generator (PSPHESG). In this topology, the electrically excited machine part (EEMP) compensates part of the output power, reducing the core saturation of the hybrid excitation machine part (HEMP), dispersing the reverse excitation field passing through the PMs, and the temperature rise caused by excitation loss. The flux-regulation efficiency and output power of the generator are also improved. Section 2 introduces the machine structure and operating principles. Section 3 investigates the magnetic field, no-load and on-load output characteristics via finite-element analysis (FEA), reveals the phase angle deviation of the phase voltage, and assesses the loss distribution and efficiency. Finally, Section 4 evaluates the anti-demagnetization capability of the PMs under fault conditions. The results show that the proposed PSPHESG is a promising candidate for SMHP.
2. Proposed PSPHESG Topology and Operating Principles
The following section presents the structure of the proposed PSPHESG and the connection topology of armature windings (AWs) and FWs. The voltage-regulation principles are discussed on the basis of the no-load equivalent magnetic circuit model. In addition, the design considerations for the axially parallel combination and the basic principle of voltage superposition are described.
2.1. Topology
The 3-D structure of the proposed PSPHESG is shown in Figure 2. The left side is the series HEMP, in which the PMs adopt a combined V-shaped and straight-shaped arrangement, while the right side is the EEMP. The two rotors are mounted on the same shaft, and the two stators share one set of AWs that are directly connected at the end. This configuration reduces copper usage and decreases both end winding resistance and leakage inductance. In addition, to provide sufficient space for winding the FWs, a certain axial gap is reserved between the rotors and stators of the HEMP and EEMP, which decouples the magnetic fields and temperature rises of the two parts and reduces the usage of the stator core. The winding layout of the HEMP and EEMP are shown in Figure 3. Both parts adopt a 6-pole/72-slot configuration and contain six pole-phase groups. The AWs uses a short-pitch distributed winding with a coil pitch of 10 slots to suppress the fifth- and seventh-order space harmonics. The FW adopts a concentrated-winding arrangement, which improves space utilization and simplifies manufacturing. The vertical dashed line in Figure 3 denotes the A-phase winding axis, and the axis of each pole-phase group is aligned with the center of the corresponding rotor pole. The main parameters of the proposed PSPHESG are listed in Table 1.
Figure 2.
3-D structure of the proposed PSPHESG.
Figure 3.
Winding layout of HEMP and EEMP.
Table 1.
Main parameters of the proposed PSPHESG.
2.2. Voltage-Regulation Principle
The voltage-regulation principle of the proposed PSPHESG is shown in Figure 4a. In Figure 4a, the AWs and FWs of the HEMP AWHEMP, FWHEMP and the EEMP AWEEMP, FWEEMP are connected in series, and the FWs are supplied by a contactless excitation system to realize brushless operation and provide a DC excitation source capable of satisfying the steady-state excitation requirement, as well as the FF and DE functions [27]. When the terminal voltage is too high, a reverse field current is injected so that the EEMP generates a reverse voltage, and the series superposed resultant voltage decreases. Conversely, when the terminal voltage is too low, positive excitation is applied, and the resultant voltage increases, thereby enabling flexible output voltage regulation. To analyze the voltage-regulation capability of the PSPHESG more accurately, the no-load equivalent magnetic circuit model is established, as shown in Figure 4b. According to the magnetic circuit model, the flux per pole of the HEMP and EEMP can be expressed as
where , , .
Figure 4.
Block diagram of the voltage-regulation principle. (a) Schematic of the circuit structure. (b) Equivalent magnetic circuit model. , , —MMFs of PM and FW in HEMP and EEMP; —equivalent magnetic reluctance of PM; , , , —magnetic reluctances of FW, rotor, air gap, and stator in HEMP; , , , —magnetic reluctances of FW, rotor, air gap, and stator in EEMP.
The total flux linkage of the AWs is as follows:
where is the number of series turns per phase; and denote the AWs flux linkages of the HEMP and EEMP, respectively.
The induced electromotive force (EMF) can be expressed as
Therefore, bidirectional voltage regulation can be realized by adjusting the field current and hence, the excitation MMF.
2.3. Design Criteria
The design flowchart of the PSPHESG is shown in Figure 5. First, all rated specifications, including the rated power, output voltage, power factor, and rotational speed, are determined. Based on these specifications, appropriate topologies are then selected for HEMP and EEMP. Secondly, The HEMP is designed to provide the major portion of the output power. Under permanent-magnet-only excitation, its output power should account for no less than 70% of the rated power. Based on the conventional design theory of PMSG, the preliminary stator radial dimensions and the axial stack length of the HEMP are calculated using Equation (5). The HEMP and EEMP are designed with identical radial dimensions to facilitate coaxial assembly. Considering the operating conditions and the requirement for preventing irreversible PM demagnetization, an N40UH PM grade is selected. The dimensions of the V-shaped PMs are subsequently determined using Equation (6).
Figure 5.
Design flowchart of PSPHESG. (a) Basic flowchart. (b) Spearman correlation analysis.
The EEMP serves as the power-compensation and voltage-regulation unit, and its axial stack length is determined by the following three constraints: (a) the output power of the EEMP should not exceed 30% of the rated power, thereby maximizing the overall power density; (b) the forward flux-regulation coefficient should be no lower than 60% to ensure sufficient excitation capability under grid faults; and (c) the residual voltage during de-excitation should not exceed 10% of the rated voltage. Finally, the axial stack length of the EEMP is determined through iterative magnetic-circuit calculations and saturation verification.
where denotes the stator inner diameter, is the effective core length, represents the per-unit full-load electromotive force, is the rated power, denotes the calculated pole-arc coefficient, is the air-gap flux-density waveform factor, represents the armature winding factor, is the rotational speed, denotes the linear electric loading, the air-gap magnetic loading, and is the rated power factor.
where denotes the machine saturation coefficient, is the air-gap coefficient, represents the air-gap length, is the relative permeability of the PM, denotes the PM operating-point flux density, is the remanent flux density of the PM, represents the leakage-flux coefficient, is the pole pitch, and denotes the axial length of the PM.
Finally, the excitation currents required under steady-state, FF, and DE conditions, along with the numbers of turns in the excitation windings of the HEMP and EEMP, need to be determined. Considering the multiple operating conditions of hydropower systems, the PSPHESG should satisfy the following requirements: when the load fluctuates within a small span, the field current should be adjusted within a certain range to stabilize the terminal voltage; when a grid fault causes the system voltage to drop sharply, the field current should be rapidly increased to 1.6–2 times its rated value to partially restore the generator terminal voltage and supply a large amount of reactive power to prevent grid-voltage collapse, with a duration of 10–20 s; when an interphase or ground short-circuit fault occurs in the stator winding at the generator terminal, the circuit breaker trips, and the generator becomes unloaded, but the EMF still exists. In this case, a large reverse current must be injected into the FW to de-excite the machine. The equivalent design criterion is given by Equation (7).
where , , and denote the field currents under steady-state, FF, and DE conditions, respectively; and denote the numbers of FW turns of the HEMP and EEMP.
Once all the basic parameters have been determined, a multi-objective optimization analysis is performed on the initial design. Several key structural parameters are selected as design variables, including the V-shaped PM-included angle , the stator-slot opening width , the PM width and thickness , the stack-length ratio between the HEMP and EEMP, and the excitation-winding turns ratio . The optimization objectives comprise the cogging torque and torque ripple , which are closely associated with vibration and noise; the total harmonic distortion THD of the no-load EMF, which characterizes the output-voltage quality; the flux-regulation coefficient kf, which reflects the voltage-regulation capability; and the sum of the iron loss and PM loss , which is related to the output efficiency. In this way, the major performance aspects of the machine are considered simultaneously. Because the optimization procedure involves a large number of steps, only the sensitivity analysis between the design variables and the optimization objectives is presented in this paper. The corresponding Spearman correlation coefficient is shown in Figure 5b. A larger indicates a stronger correlation between the two indicators. It can be observed that k1 exhibits strong correlations with kf and . In addition, and show relatively high correlation coefficients with THD The variation in hpm also has a significant influence on . Among all the optimization objectives, the exhibits the weakest correlations with the design variables. Therefore, in the subsequent simulation analysis, the machine performance can be further improved by appropriately adjusting the value of , , , and .
In addition, effective EMF superposition can be achieved between the HEMP and EEMP when the following conditions are satisfied: (1) identical electrical frequency; (2) identical phase number; and (3) identical initial phase angle of the no-load EMF. Since both parts are three-phase machines, and the initial phase angle of the no-load EMF can be ensured by design and manufacturing, only the equality of electrical frequency must be satisfied, which can be expressed as
where is the electrical frequency, and denote the speed and pole-pair number of the HEMP; and denote the speed and pole-pair number of the EEMP.
Since the rotors of the two parts are coaxially connected, it can be obtained that
By combining Equations (8) and (9), it can be deduced that
Therefore, the HEMP and EEMP must have the same number of pole pairs.
3. Electromagnetic Performance Analysis
To investigate the electromagnetic performance of the PSPHESG, the magnetic field distribution, no-load output characteristics, voltage phase angle deviation, and on-load output characteristics are analyzed via FEA. Due to fact that the flux path of the HEMP and EEMP are relatively independent, the 2-D field-circuit coupled model can be used instead of the 3-D model to analyze the output characteristics and improve simulation efficiency [22]. The loss and efficiency of the PSPHESG are also investigated.
3.1. Analysis of Magnetic Field
Figure 6 shows the flux distribution and flux density contours of the HEMP and EEMP under different field currents. The flux density distributions of V-shaped PM and combined PM are compared in Figure 6a,b. Compared with the V-shaped PM, the combined PM structure produces higher flux density at the pole center and tooth region, indicating a certain flux-concentrating effect and hence, higher power density. In the HEMP, the PM and FW flux jointly pass through the pole body. In the flux-enhancing mode, the flux density in this region increases markedly, whereas it remains relatively low in the flux-weakening mode, demonstrating good flux-regulation capability. In the EEMP, when the field current is 35 A and −35 A, the flux density in the pole body and tooth region remains low (approximately 1.03 T), indicating that the EEMP can withstand a large field current without magnetic saturation.
Figure 6.
Flux distribution and flux density contours of HEMP and EEMP. (a) HEMP with If = 35 A. (b) HEMP with If = −35 A. (c) EEMP with If = 35 A and −35 A.
The corresponding air-gap flux density waveforms are shown in Figure 7. According to the principle of minimum reluctance, the flux of the V-shaped PM structure is mainly distributed on both sides of the magnet. This feature produces a magnetic field distribution with a weak center and strong sides at the pole, causing air-gap flux density distortion and a waveform close to a rectangular shape. In the combined PM structure, the flux-concentrating effect of the straight PM concentrates the flux in the pole-center region, and the air-gap flux density waveform becomes closer to a sinusoid. Therefore, the combined PM structure can provide a more favorable air-gap flux density distribution, and it is selected as the HEMP structure in this paper.
Figure 7.
Air-gap flux density waveforms of HEMP and EEMP. (a) HEMP with If = 35 A. (b) HEMP with If = −35 A. (c) EEMP with If = 35 A and −35 A.
Due to fact that the HEMP contributes the larger proportion of the output power in the PSPHESG, the torque ripple of the PSPHESG mainly originates from the cogging torque generated by the HEMP. The cogging torque of the HEMP under different field currents is shown in Figure 8. When a negative field current is applied, the air-gap flux density waveform is distorted to a certain extent (Figure 7b), increasing the amplitudes of specific harmonics related to cogging torque and thereby increasing the cogging torque. Under no excitation and positive excitation, the cogging torque is relatively small.
Figure 8.
Cogging torque of HEMP.
3.2. No-Load Output Characteristics
Figure 9 shows the superposed no-load phase EMF waveforms of the PSPHESG under different field currents. The phase EMFs of the HEMP and EEMP have the same electrical frequency and initial phase angle and can therefore be linearly superposed. When the field current is positive, the phase EMFs of the HEMP and EEMP are in the same direction, which helps increase the output voltage and restore the terminal voltage under grid-fault conditions. When the field current is negative, the phase EMFs of the HEMP and EEMP are opposite, which suppresses the voltage under short-circuit fault conditions. The fundamental and harmonic amplitudes of the superposed phase EMF waveforms at field currents of −120 A and 85 A, obtained by Fourier transform, are shown in Figure 10. At −120 A, the fundamental components of the two parts are superposed in opposite directions, significantly reducing the fundamental amplitude of the resultant phase EMF. Meanwhile, because the third harmonic of the HEMP is relatively large and the third harmonics of the two parts are superposed in the same direction, the third harmonic of the PSPHESG increases. Nevertheless, the RMS value of the phase EMF is approximately 15% of the rated phase voltage, which essentially achieves the DE effect and meets practical engineering requirements. Conversely, at 85 A, the fundamental components of the two parts are superposed in the same direction, while the third harmonics are superposed in opposite directions. As a result, the fundamental amplitude of the PSPHESG increases, and the third harmonic is suppressed, which is beneficial for restoring the system voltage in FF mode.
Figure 9.
Superposed no-load phase EMF waveforms.
Figure 10.
Harmonic amplitudes of the no-load phase EMF. (a) If = −120 A. (b) If = 85 A.
Figure 11 presents the no-load characteristics of the PSPHESG at different speeds. When the field current is 0 A, the no-load phase EMF is generated entirely by the PMs and increases with increasing field current, indicating good voltage-regulation capability. When the field current exceeds 85 A, the cores of the two parts tend to saturate, and the increase in the no-load phase EMF becomes small. When the field current decreases to −120 A, the no-load phase EMF is almost cancelled, and the machine enters the DE state.
Figure 11.
No-load characteristic.
To more accurately evaluate the voltage-regulation capability of the PSPHESG, the flux-regulation coefficient is introduced and defined as
where and denote the RMS phase voltages of the PSPHESG under hybrid excitation and pure PM excitation, respectively. Figure 12 shows the with variation of field current at different speeds. The speed has almost no influence on the . at no load. Under positive excitation near magnetic saturation, the reaches 63.7%. As the field current increases in the negative direction, the coefficient also increases negatively and reaches a maximum of −96.9%, indicating that the armature magnetic field is almost eliminated, confirming the wide flux-regulation range of the PSPHESG.
Figure 12.
γ versus field current.
3.3. Phase Angle Deviation
Under load conditions, the difference between the flux path structures of the rotors of the two parts produces a significant time-phase shift between the phase voltages of the HEMP and EEMP, which in turn affects the voltage synthesis and power output of the whole machine [25,28].
Figure 13 shows the d-axis and q-axis inductances of the HEMP and EEMP versus the field current. In the HEMP, the d-axis flux path is affected by the PMs and therefore, has a relatively small inductance, whereas the q-axis flux closes through the rotor core path, resulting in a larger inductance and an inverse saliency characteristic. In contrast, the EEMP has no PMs, and the d-axis reluctance is smaller. Therefore, under the same armature current, the armature reaction levels of the two parts are different, leading to phase angle deviation between their phase voltages.
Figure 13.
Inductances of HEMP and EEMP versus field current at load. (a) D-axis inductance. (b) Q-axis inductance.
The AW flux linkages of the HEMP and EEMP at no load and load are shown in Figure 14. At no-load operation, the flux linkages of the two parts are in phase and have relatively large amplitudes. At load operation, the demagnetizing effect of the armature reaction significantly reduces the flux linkage amplitudes, with a larger decrease in the EEMP, indicating stronger armature reaction in the EEMP. In addition, the load flux linkages lag those of their no-load counterparts by a certain phase angle.
Figure 14.
AW flux linkages of HEMP and EEMP at no-load and load (If = 35 A). (a) HEMP. (b) EEMP.
Figure 15a further illustrates the phase voltage waveforms of the HEMP, EEMP, and PSPHESG at rated load. The phase voltage of the PSPHESG is the sum of the phase voltages of the HEMP and EEMP, and the phase difference between the two parts affects the sinusoidal quality of the PSPHESG phase voltage waveform. The fundamental waveforms and harmonic amplitudes obtained by the Fourier decomposition of Figure 15a are shown in Figure 15b,c. Since the HEMP phase voltage leads the EEMP phase voltage by a certain angle, the fundamental amplitude of the PSPHESG is smaller than the arithmetic sum of their fundamental amplitudes, which indicates that the phase deviation weakens the effective voltage superposition and is an important factor influencing the output voltage of the PSPHESG. In addition, the HEMP is affected by q-axis armature reaction and exhibits a relatively high total harmonic distortion (THD). After superposition, the third harmonic of the PSPHESG is relatively large; however, triplen harmonics do not appear in the terminal voltage.
Figure 15.
Phase voltage waveforms and phase angle deviation at load (If = 35 A). (a) Original waveforms. (b) Fundamental waveforms. (c) Harmonic amplitudes and THD.
The phasor relationships shown in Figure 16 theoretically explain the load-voltage phase angle deviation phenomenon. Neglecting the stator winding resistance, the corresponding phasor equations are expressed as
Figure 16.
Phasor diagrams of HEMP, EEMP, and PSPHESG at load. (a) HEMP. (b) EEMP. (c) PSPHESG (δee > 90°). (d) PSPHESG ( < 90°). (, , —no-load induced EMFs of HEMP, EEMP, and PSPHESG; , , —phase voltages of HEMP, EEMP, and PSPHESG; I—phase current; , —d-axis and q-axis currents; , , —d-axis and q-axis synchronous reactance of HEMP, EEMP, and PSPHESG; , , —power angles of HEMP, EEMP, and PSPHESG; —internal power factor angle; —power factor angle; —core length of EEMP).
The internal power factor angle ψ and power angle δ are expressed as
where Ud and Uq denote the projections of the phase voltage on the d-axis and q-axis, respectively.
From Figure 16a and Equation (17), it can be seen that the phase of mainly depends on the power angle . The presence of PMs yields a relatively large , while the d-axis inductance is relatively low, is always less than 90°, and leads the . However, only the FW is present in the EEMP, and is relatively small such that , causing to exceed 90°, as shown in Figure 16b. As a result, leads the , and their superposition gives ; the corresponding phasor diagram is shown in Figure 16c. It should be noted that is positively correlated with . Since , the magnitude of and decrease as and increase, the magnitude of , therefore, increases only slightly. In Figure 16d, when is sufficiently large such that , the magnitude of increases markedly as and increase, improving the degree of effective superposition.
3.4. On-Load Output Characteristics
Figure 17 shows the with variation of field current at different loads. As the load impedance decreases, the voltage produced by pure PM excitation becomes smaller, resulting in a higher . Increasing the field current can raise the at rated load to more than 90%.
Figure 17.
γ versus field current at load ( = 1000 r/min; is rated load impedance).
The open-loop external characteristics of the PSPHESG under different field currents are shown in Figure 18. For a fixed field current, the output voltage decreases as the load current increases because of the armature reaction, internal voltage drop, and the phase deviation between the HEMP and EEMP. This voltage droop represents the natural load characteristic under fixed excitation and does not correspond to the regulated terminal-voltage characteristic in practical operation. At the rated load current of 509.13 A, the operating point shifts from A to B as the field current increases from 0 A to 35 A, indicating that the rated voltage of 6.3 kV lies within the adjustable voltage range and that the PSPHESG has sufficient flux-regulation capability to maintain the rated terminal voltage under load.
Figure 18.
Output voltage versus load current (n = 1000 r/min).
The constant-voltage characteristic of the generator is affected by load and power factor (PF), and the field current must be adjusted to maintain a stable output voltage. Figure 19 shows the regulation characteristics of the PSPHESG including variation of PF with an output voltage of 6.3 kV. The PSPHESG can deliver a constant voltage over a wide PF range. A lower PF strengthens the demagnetizing armature reaction and therefore, requires a larger field current for voltage stabilization. At the rated PF (0.9), voltage stabilization during load fluctuation within a certain range can be achieved with a relatively small field-current range, indicating effective constant voltage characteristics under steady-state condition. Figure 20 shows the output power versus field current at different PFs with an output voltage of 6.3 kV. For the same field current, the output power decreases as the PF decreases. This is because no armature reaction exists at PF = 1, whereas armature reaction limits the output-power capability when PF < 1.
Figure 19.
Regulation characteristics (UO = 6.3 kV; n = 1000 r/min).
Figure 20.
Output power versus field current (UO = 6.3 kV; n = 1000 r/min).
Figure 21 shows the loss and efficiency of the PSPHESG versus field current at an output voltage of 6.3 kV. The losses mainly include copper loss (AW and FW loss), iron loss, and PM loss, while mechanical loss and windage loss are neglected. Copper loss accounts for the dominant portion of the total loss, whereas iron loss and PM loss are relatively small. As the field current increases, the total loss increases significantly, but the efficiency changes only slightly and remains above 96%.
Figure 21.
Loss and efficiency versus field current (UO = 6.3 kV; n = 1000 r/min).
To evaluate the comprehensive performance of the proposed PSPHESG against conventional solutions for SMHP, a quantitative comparison is conducted under a unified 5 MW, 1000 r/min, 6.3 kV, 50 Hz rated condition. Power density is calculated based on the total stator core volume to ensure a consistent and fair comparison across topologies. Parameters of conventional topologies are derived from published literature and industrial design standards, and the results are summarized in Table 2. As shown in Table 2, although the proposed PSPHESG requires a relatively large amount of permanent-magnet material, it achieves comparatively high power density and rated efficiency, which is beneficial for reducing its long-term operating cost.
Table 2.
Performance comparison of different generator topologies.
4. PM Demagnetization Analysis
During long-term operation, the generator may encounter various operating conditions that threaten machine safety, among which irreversible PM demagnetization is the most severe [29]. It is therefore necessary to evaluate and analyze PM demagnetization under steady-state operation, FF, and DE. In addition, a partition can be installed in the gap between the HEMP and EEMP so that their temperature rise and magnetic field do not affect each other. Thus, only the HEMP needs to be considered in the PM demagnetization analysis.
There are many potential causes of PM demagnetization, among which high temperature and reverse magnetic field are the main factors [30]. In this paper, the losses of each component obtained from the finite-element analysis (Maxwell) are imported as thermal loads into Ansys Workbench to calculate the PM temperature rise. The prerequisites are as follows: (1) the worst-case condition is considered, with the ambient temperature set to 40 °C; (2) axial forced-air cooling is adopted. The temperature-field results are then imported back into Maxwell to analyze PM demagnetization under the simultaneous effects of temperature rise and reverse magnetic field. The bidirectionally coupled electromagnetic–thermal analysis flowchart is shown in Figure 22. Before the temperature-rise calculation, the material properties of the machine components must be defined, as listed in Table 3.
Figure 22.
Flowchart of the PM demagnetization analysis.
Table 3.
The material properties of HEMP.
In addition, the PM grade is N40UH. Its intrinsic demagnetization curves (J-H) and demagnetization curves (B-H), with variation in temperature, are shown in Figure 23.
Figure 23.
Demagnetization curves of N40UH with variation in temperature. Solid lines show intrinsic demagnetization curves (J-H); dashed lines show demagnetization curves (B-H).
4.1. Steady State
The generator operates under steady-state conditions for most of the service time. During this period, the PMs are affected by both the demagnetizing field of the armature reaction and the temperature rise caused by their own eddy current loss and heat conducted from other components. The temperature-field simulation time is set to 18,000 s, and the steady-state PM temperature versus load current under different cooling air velocities is shown in Figure 24. A higher cooling air velocity significantly reduces the steady-state PM temperature. However, due to the fact that heat transfer inside the PMs is limited by the thermal resistance of the rotor structure, the temperature does not decrease proportionally with air velocity. The maximum temperature (83.92 °C) is selected for PM demagnetization analysis, and the minimum flux density of the PMs is shown in Figure 25. The minimum PM flux density is 0.58 T, which is higher than the knee-point flux density at 100 °C (−0.4 T), indicating no demagnetization risk.
Figure 24.
PM temperature versus load current.
Figure 25.
Minimum PM flux density.
4.2. FF
When FF is required, the armature current is usually large. Therefore, the FF condition is simulated by connecting a small load impedance at the machine terminals. Under this condition, the PMs are subjected to a large reverse armature field. In addition, the increased space harmonics passing through the PMs lead to considerable PM eddy-current loss, and the injected field current of 85 A further raises the temperature around the PMs. Since FF lasts only 20–30 s, a duration of 40 s is used for the temperature-rise calculation. Before the FF condition occurs, the generator is assumed to operate in the steady state, and the maximum steady-state temperature (83.92 °C) is taken as the initial temperature. Considering cost, the cooling air velocity is set to 10 m/s. Figure 26 shows the PM temperature-rise curves under different loads under FF condition. The PM temperatures remain below the maximum operating temperature (180 °C). The minimum flux density of the PMs at the corresponding maximum temperature is shown in Figure 27. Under low load impedance conditions, the minimum flux density is higher than the knee point flux density of the demagnetization curve at the corresponding temperature, indicating that irreversible demagnetization does not occur under FF conditions.
Figure 26.
PM temperature rise at different loads ( = 85 A).
Figure 27.
Minimum PM flux density at different loads.
4.3. DE
When DE is required, the generator is in the no-load state. The PM temperature rise caused by eddy-current loss can then be neglected, and the demagnetization risk mainly arises from the large reverse excitation field and the heat conducted from the FW. The field current required for DE is −120 A. Although the loss generated by the FW causes a large temperature rise, the steady-state PM temperature is only 53.2 °C because of the low thermal conductivity of the rotor core. The resulting PM demagnetization coefficient is shown in Figure 28, and its expression is given in Equation (18). A larger coefficient indicates more irreversible demagnetization, while a value of 1 indicates no demagnetization. As shown in Figure 28, the minimum demagnetization coefficient is 0.9893, corresponding to a demagnetization rate of only approximately 1.07%. Some corner regions exhibit a slightly smaller coefficient of 0.9860; however, these regions are very small, and the difference in coefficient is limited, so their effect can be neglected.
where and denote the initial remanence and equivalent remanence after demagnetization of PMs, respectively.
Figure 28.
PM demagnetization coefficient. (a) Demagnetization coefficient curve. (b) Demagnetization coefficient contour.
5. Conclusions and Discussion
This paper proposes and analyzes a novel axially parallel hybrid excitation synchronous generator as an alternative to electrically excited machine designs in order to meet the requirements of the SMHP systems for high power density, wide-range voltage regulation, and safe operation under fault conditions. The topology combines a HEMP and an EEMP mounted on the same shaft. While retaining the high-power-density advantage of PM machines, it improves voltage-regulation capability and reduces the PM demagnetization risk under FF and DE conditions. The main conclusions are as follows.
(1) The two machine parts can achieve effective no-load EMF superposition. The finite-element results show that the combined PM structure improves the air-gap flux density distribution of the HEMP and that the EEMP does not exhibit obvious saturation under either positive or negative excitation. The maximum positive and negative flux regulation coefficient of the PSPHESG reach 63.7% and −96.9%, respectively, demonstrating a wide flux-regulation range.
(2) On load, the difference in armature reaction between the HEMP and EEMP produces a phase relationship such that leads , and lags , weakening the effective superposition of voltages. The phasor analysis shows that reasonable adjustment of the EEMP core length and field current can improve load-voltage synthesis, but saturation, volume, and cost constraints must be considered.
(3) The load output results verify the steady-state constant-voltage capability of the PSPHESG. At the rated PF, increasing the field current from 0 A to 35 A is sufficient to compensate for the terminal voltage drop, and a 6.3-kV output voltage can be maintained under different PFs. The loss is dominated by copper loss, and the efficiency remains above 96%.
(4) The coupled electromagnetic–thermal analysis shows that the PMs do not exceed the demagnetization risk boundary under steady-state, FF, or DE conditions. Under the DE condition, the minimum demagnetization coefficient is 0.9893, corresponding to a demagnetization rate of approximately 1.07%. Therefore, the proposed structure can realize FF and DE functions while avoiding obvious irreversible demagnetization.
Author Contributions
Conceptualization, J.L.; methodology, J.L.; software, J.L.; validation, J.L.; formal analysis, J.L. and B.S.; investigation, J.L.; resources, Z.J.; data curation, B.S.; writing—original draft preparation, J.L.; writing—review and editing, Z.J.; visualization, J.L.; supervision, Z.J.; project administration, Z.J.; funding acquisition, Z.J. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
Data will be made available on request.
Acknowledgments
The authors would like to thank Zhijun Jiang for his valuable guidance and continuous support throughout this research.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Kougias, I.; Aggidis, G.; Avellan, F.; Deniz, S.; Lundin, U.; Moro, A.; Muntean, S.; Novara, D.; Pérez-Díaz, J.I.; Quaranta, E.; et al. Analysis of emerging technologies in the hydropower sector. Renew. Sustain. Energy Rev. 2019, 113, 109257. [Google Scholar] [CrossRef] [Scilit]
- Liszka, D.; Krzemianowski, Z.; Węgiel, T.; Borkowski, D.; Polniak, A.; Wawrzykowski, K.; Cebula, A. Alternative Solutions for Small Hydropower Plants. Energies 2022, 15, 1275. [Google Scholar] [CrossRef] [Scilit]
- Borkowski, D. Analytical Model of Small Hydropower Plant Working at Variable Speed. IEEE Trans. Energy Convers. 2018, 33, 1886–1894. [Google Scholar] [CrossRef] [Scilit]
- Gao, J.; Dai, L.; Liu, X.; Du, X.; Luo, D.; Huang, S. Variable-Speed Hydropower Generation: System Modeling, Optimal Control, and Experimental Validation. IEEE Trans. Ind. Electron. 2021, 68, 10902–10912. [Google Scholar] [CrossRef] [Scilit]
- Noland, J.K.; Nuzzo, S.; Tessarolo, A.; Alves, E.F. Excitation System Technologies for Wound-Field Synchronous Machines: Survey of Solutions and Evolving Trends. IEEE Access 2019, 7, 109699–109718. [Google Scholar] [CrossRef] [Scilit]
- Nuzzo, S.; Bolognesi, P.; Decuzzi, G.; Giangrande, P.; Galea, M. A Consequent-Pole Hybrid Exciter for Synchronous Generators. IEEE Trans. Energy Convers. 2021, 36, 368–379. [Google Scholar] [CrossRef] [Scilit]
- Xia, Y.; Huang, H.; Zhu, Z.; Guo, H.; Chen, Y. Brushless Excitation Principle and Experimental Verification of Hybrid Excitation Synchronous Generator Based on Harmonic Magnetic Field. IEEE Access 2022, 10, 85146–85153. [Google Scholar] [CrossRef] [Scilit]
- Borkowski, D.; Węgiel, T.; Kisielewski, P.; Liszka, D. Universal Modular Permanent Magnet Synchronous Generator for Small Low-Head Hydropower Plants. IEEE Trans. Energy Convers. 2023, 38, 2884–2894. [Google Scholar] [CrossRef] [Scilit]
- Di Dio, V.; Cipriani, G.; Manno, D. Axial Flux Permanent Magnet Synchronous Generators for Pico Hydropower Application: A Parametrical Study. Energies 2022, 15, 6893. [Google Scholar] [CrossRef] [Scilit]
- Zhu, Z.Q.; Cai, S. Overview of Hybrid Excited Machines for Electric Vehicles. In Proceedings of the 2019 Fourteenth International Conference on Ecological Vehicles and Renewable Energies (EVER); IEEE: Monte-Carlo, Monaco, 2019; pp. 1–14. [Google Scholar]
- Zhu, Z.Q.; Cai, S. Hybrid excited permanent magnet machines for electric and hybrid electric vehicles. Trans. Electr. Mach. Syst. 2019, 3, 233–247. [Google Scholar] [CrossRef] [Scilit]
- Liu, Y.; Zhang, Z.; Zhang, X. Design and Optimization of Hybrid Excitation Synchronous Machines with Magnetic Shunting Rotor for Electric Vehicle Traction Applications. IEEE Trans. Ind. Appl. 2017, 53, 5252–5261. [Google Scholar] [CrossRef] [Scilit]
- Liu, Y.; Zhang, Z.; Wang, C.; Gao, H. Optimization and Performance Improvement of a Hybrid Excitation Synchronous Machine with Modular Magnetic-Shunting Rotor. IEEE Trans. Ind. Electron. 2020, 67, 4381–4390. [Google Scholar] [CrossRef] [Scilit]
- Mörée, G.; Leijon, M. Overview of Hybrid Excitation in Electrical Machines. Energies 2022, 15, 7254. [Google Scholar] [CrossRef] [Scilit]
- Hua, H.; Zhu, Z.Q. Comparative Study of Series and Parallel Hybrid Excited Machines. IEEE Trans. Energy Convers. 2020, 35, 1705–1714. [Google Scholar] [CrossRef] [Scilit]
- Hua, H.; Zhu, Z.Q.; Zhan, H. Novel Consequent-Pole Hybrid Excited Machine with Separated Excitation Stator. IEEE Trans. Ind. Electron. 2016, 63, 4718–4728. [Google Scholar] [CrossRef] [Scilit]
- Wang, D.; Zhang, D.; Xue, D.; Peng, C.; Wang, X. A New Hybrid Excitation Permanent Magnet Machine with an Independent AC Excitation Port. IEEE Trans. Ind. Electron. 2019, 66, 5872–5882. [Google Scholar] [CrossRef] [Scilit]
- Hua, H.; Zhu, Z.Q. Novel Parallel Hybrid Excited Machines with Separate Stators. IEEE Trans. Energy Convers. 2016, 31, 1212–1220. [Google Scholar] [CrossRef] [Scilit]
- Cai, S.; Zhu, Z.Q.; Mipo, J.-C.; Personnaz, S. A Novel Parallel Hybrid Excited Machine with Enhanced Flux Regulation Capability. IEEE Trans. Energy Convers. 2019, 34, 1938–1949. [Google Scholar] [CrossRef] [Scilit]
- Yu, J.; Zhu, S.; Liu, C.; Wang, K. Analysis of a novel hybrid excitation synchronous generator with AC field winding. IEEE Trans. Energy Convers. 2025, 40, 1190–1202. [Google Scholar] [CrossRef] [Scilit]
- Geng, W.; Zhang, Z.; Jiang, K.; Yan, Y. A New Parallel Hybrid Excitation Machine: Permanent-Magnet/Variable-Reluctance Machine with Bidirectional Field-Regulating Capability. IEEE Trans. Ind. Electron. 2015, 62, 1372–1381. [Google Scholar] [CrossRef] [Scilit]
- Sun, L.; Zhang, Z.; Yu, L.; Gu, X. Development and Analysis of a New Hybrid Excitation Brushless DC Generator with Flux Modulation Effect. IEEE Trans. Ind. Electron. 2019, 66, 4189–4198. [Google Scholar] [CrossRef] [Scilit]
- Li, X.; Shen, F.; Yu, S.; Xue, Z. Flux-Regulation Principle and Performance Analysis of a Novel Axial Partitioned Stator Hybrid-Excitation Flux-Switching Machine Using Parallel Magnetic Circuit. IEEE Trans. Ind. Electron. 2021, 68, 6560–6573. [Google Scholar] [CrossRef] [Scilit]
- Miao, Z.; Zhang, Z.; Geng, W.; Liu, Y. Electromagnetic Torque Performance Analysis of a Parallel Hybrid Excitation Machine with Axial Paralleling of Permanent Magnet Part and Variable Reluctance Part. IEEE Trans. Magn. 2017, 53, 8207704. [Google Scholar] [CrossRef] [Scilit]
- Xue, H.; Zhang, Z.; Liu, Y.; Gao, H.; Yao, Y. A decoupled flux path hybrid excitation DC generator combining direct-drive permanent magnet and geared flux modulation machines. IEEE Trans. Ind. Electron. 2025, 72, 188–197. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Y.; Zhang, X.; Ren, J.; Meng, F.; Wu, J.; Pang, X.; Liu, W.; Kong, Z. Analysis of electromagnetic performance of permanent magnet and convex pole electromagnetic hybrid excitation generator. IEEE Trans. Energy Convers. 2024, 39, 1216–1229. [Google Scholar] [CrossRef] [Scilit]
- Liu, J.; Jiang, Z.; Yin, Z.; Shao, B. Design of a Contactless Excitation System Based on High-Power Rotary Transformers. J. Electr. Eng. Technol. 2026, 21, 3813–3830. [Google Scholar] [CrossRef] [Scilit]
- Sun, L.; Zhang, Z.; Yu, L.; Gu, X.; Vansompel, H.; Sergeant, P. Design and Analysis of Hybrid Excitation Generators for Aircraft Applications Under Limiting Open-Circuit Voltage. IEEE Trans. Transp. Electrif. 2022, 8, 3390–3400. [Google Scholar] [CrossRef] [Scilit]
- Gyftakis, K.; Rasid, S.; Skarmoutsos, G.; Mueller, M. The Demagnetization Harmonics Generation Mechanism in Permanent Magnet Machines with Concentrated Windings. IEEE Trans. Energy Convers. 2021, 36, 2934–2944. [Google Scholar] [CrossRef] [Scilit]
- Baranski, M.; Szelag, W.; Lyskawinski, W. Experimental and Simulation Studies of Partial Demagnetization Process of Permanent Magnets in Electric Motors. IEEE Trans. Energy Convers. 2021, 36, 3137–3145. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.