Ultra-High-Speed Permanent Magnet Synchronous Motors in Fuel Cell Air Compressors

,
,
and
Institute of Novel Semiconductor, Shandong University, Jinan 250100, China
*
Author to whom correspondence should be addressed.

Abstract

Driven by the rapid development of automotive fuel cells, compact and lightweight system demands require upgraded centrifugal air compressors, as conventional high speed motors at 50,000–80,000 rpm within 15 kW fail to meet current specifications. Since motor size and weight are dominated by torque, raising the rotational speed to improve power density has become the mainstream direction for ultra high speed permanent magnet synchronous motors (HSPMSMs), targeting over 100,000 rpm and 30 kW for fuel cell air compressor applications. This paper presents an 18-slot 2-pole HSPMSM with parallel magnetization, which achieves 35 kW rated power at 100,000 rpm. Electromagnetic performance, rotor mechanical strength, thermal behavior and rotor dynamics are systematically optimized by simulations and experiments.

1. Introduction

Driven by the advancement of new energy vehicles, proton exchange membrane fuel cells (PEMFCs) have become the leading vehicular fuel cell technology. They offer high efficiency, low emissions, and low noise via direct chemical-to-electrical energy conversion [1,2,3]. A typical PEMFC system consists of the stack, hydrogen/oxygen supply, thermal management, power conversion, and control units. Within this architecture, the air compressor must satisfy multiple stringent requirements. These include high efficiency, compactness, oil free operation, wide flow and pressure ranges, low acoustic noise, shock and vibration resistance, and fast dynamic response. Consequently, centrifugal air compressors have become the mainstream and market dominant solution. Figure 1a,b presents its schematic and performance map. To meet these demands, boosting motor power density to 10 kW/kg is critical. This is achieved by raising the rotational speed to 100–120 krpm [4,5] and the output power to 25 kW [6,7,8]. However, this pursuit of increased power density and ultra high speed introduces prominent challenges. These challenges particularly concern thermal management [9] and efficiency optimization for subsequent design phases. From the high speed motor design perspective, current research focuses on structural configuration optimization, the application of low iron-loss silicon steel laminations, and rotor mechanical integrity. These efforts aim to address key issues related to motor reliability, efficiency, and acoustic noise under high speed operating conditions [10,11]. Nevertheless, these studies do not cover all aspects of high speed motor engineering. In particular, the manufacturing processes of stators and rotors, along with the fabrication-oriented adaptations required for stable wide range operation, remain insufficiently explored and warrant further investigation.
Figure 1. Centrifugal air compressor: (a) Centrifugal Air Compressor schematic diagram. (b) Air compressor performance map.
Furthermore, such motors normally operate within an ultra high speed range from 90,000 to 150,000 r/min [12,13]. This operation leads to critical challenges, such as concentrated loss distribution, severe temperature rise, and substantial mechanical loads on the rotor structure. Additionally, the high temperature compressed air on the discharge side further worsens the motor thermal field. It significantly increases the risk of irreversible demagnetization of the permanent magnets and thus limits the overall service life of the system [14,15]. While existing studies mainly concentrate on electromagnetic and thermal field simulations, the practical manufacturing concerns are overlooked. Specifically, the systematic manufacturing processes for high speed motors remain inadequately addressed. The structural forming and thermal dissipation channel machining under multi-physics coupling conditions also require more attention [16,17,18,19]. Existing research on high-speed driving systems for fuel cell centrifugal air compressors can be categorized into aerodynamic optimization of two-stage compression units, multi-physics design of high speed motors, and integrated system control. Guo et al. proposed a corrected specific speed multi-objective optimization method for two-stage series centrifugal compressors, which greatly widened the efficient operating range of the 100 kW fuel cell air supply device [16]. But the matching loss of driving motors was not incorporated into the design cycle. Aiming at the torque coupling interference of turbine recovery type compressors, Zhong et al. designed an improved optimal sliding mode controller to enhance speed tracking stability, yet the model simplified the two-stage impeller aerodynamic nonlinear coupling effect under off-design conditions [19]. At present, few studies carry out collaborative optimization of two-stage compressor aerodynamics and matched high speed motors covering the whole working condition, which restricts the overall energy efficiency improvement of fuel cell air supply subsystems.
The electromagnetic torque of an electric motor T e is a function of various factors, including the structural parameters of the motor, the winding configuration, spatial permeance distribution, and both electric and magnetic loading. The power of an electric motor is P e . This relationship can be mathematically expressed as shown:
T e = P e ω e = K · α · K a m · K d p · A · B δ · ( D 2 L )
where T e , P e , ω e , D, and L are the electromagnetic torque, electromagnetic power, speed, outer diameter, and length of core, respectively. K is a constant. α , K a m , K d p , A, and B δ are the pole arc coefficient, waveform coefficient of magnetic flux density, winding factor, electric loading, and magnetic loading, respectively. The electromagnetic torque of a radial-flux permanent-magnet motor is fundamentally limited by the air gap shear stress. This shear stress is proportional to the product of the electric loading A and the magnetic loading B δ . For a given shear stress, the torque scales linearly with the motor’s active volume, which is defined as D 2 L , where D is the stator bore diameter and L is the active axial length. Equation (1) illustrates that the ratio of the electromagnetic power P e to the rotational speed n e is proportional to the motor’s volume. This relationship implies that, under a constant power constraint, increasing the motor’s rotational speed allows for a reduction in its physical volume. Conversely, for a fixed motor volume, a higher rotational speed enables a greater power output. This fundamental principle serves as the cornerstone for designing compact, high power density motors, which are essential components in fuel cell air compressor systems.
This paper presents a systematic optimization of slot-pole configurations for ultra high speed motors. Given the ultra high speed operating limit, a 2-pole topology is adopted. The slots per pole per phase range from 1 to 4, yielding four distinct configurations. These include the 6-slot/2-pole, 12-slot/2-pole, 18-slot/2-pole, and 24-slot/2-pole designs. Their performance is compared based on main pole harmonics, armature magnetic field harmonics, induced eddy current loss, and vibration and noise characteristics. The results reveal that the 18-slot/2-pole configuration effectively suppresses tooth harmonics and armature field harmonics. This configuration also reduces air gap harmonic content and eddy current losses. Consequently, it significantly improves the motor’s electromagnetic and acoustic performance. To further enhance the vibration and noise performance, a parallel magnetized magnetic pole structure is proposed to suppress the harmonic content of the no-load air gap flux density. A comprehensive evaluation is conducted covering the motor’s electromagnetic characteristics, harmonic features, structural integrity, and temperature field. A dedicated design and optimization process for ultra high speed motors is thereby established. Prototype tests validate the effectiveness of the proposed approach. The results confirm that the motor achieves high efficiency, low noise, and superior reliability. Consequently, the motor has been mass-produced and widely recognized by industrial customers.
This paper focuses on the high speed motor design for fuel cell centrifugal air compressors. The key performance indicators are analyzed in Section 2. A motor configuration is proposed with three slots per pole per phase, an axially segmented rotor, and parallel magnetization. This design aims to achieve high efficiency, low noise, and reliable high speed operation. Section 3 investigates the thermal management, rotor structural reliability, and rotor dynamics. Section 4 develops a high speed motor with high efficiency, low noise, and high reliability. Its performance is validated through prototype tests to ensure it meets practical application and mass-production requirements. Finally, Section 5 summarizes the main innovations and research conclusions.

2. The Performance Analysis of HSPMSMs

2.1. The Loss of High Speed Motor

High speed centrifugal compressors are typically driven by permanent magnet synchronous motors (PMSMs), with operational speeds frequently exceeding 50,000 rpm. The dominant loss components in such machines encompass stator copper loss, stator iron loss, rotor eddy current loss, stray loss, and windage and friction losses. Based on the fundamental principles of Faraday’s law of electromagnetic induction, the alternating magnetic flux induces circulating eddy currents within the silicon steel laminations [20]. The resultant total eddy loss can be derived by integrating the loss density over the core volume. Consequently, the classical iron loss separation model, which decomposes losses into hysteresis and eddy current components via the standard Steinmetz two-term method, is widely adopted for high speed motor loss calculation [20,21]. It should be noted that this analytical framework is established under the following simplifying assumptions: the silicon steel operates strictly within its linear magnetization region while minor high-frequency losses below 1 kHz are neglected. And only alternating magnetization is considered, thereby excluding rotational iron losses—a valid approximation for the stator yoke and teeth of ultra high speed motors subject to unidirectional alternating flux. The hysteresis and eddy current loss coefficients are empirically obtained via material B-H curve testing across the rated frequency range; and the motor is presumed to operate under a sinusoidal air gap fundamental magnetic field without entering deep magnetic saturation. The copper loss is determined by the stator winding resistance and the armature current, which is expressed as:
P c u = 3 · I 2 · R
where I and R are RMS value of armature current and armature resistance. The eddy current loss arises from the circulating currents induced by the alternating magnetic flux within the silicon steel laminations. It is expressed as:
P w = K w · f 2 · B d 2 · V / r
where K w , f, B d , V and r are the eddy current loss coefficient, electrical frequency, fundamental magnetic flux density, volume of the stator core and electrical resistivity of silicon steel, respectively. Based on Faraday electromagnetic induction law, alternating magnetic flux induces circulating eddy current inside silicon steel sheet [20]. The hysteresis loss is attributed to the energy dissipation during the cyclic magnetization of the core material. It is expressed as:
P h = K h · f · B a · V
where K h and B are the hysteresis loss coefficient and fundamental magnetic flux density, respectively. Basic synchronous machine fundamental frequency-speed relation is given by [22,23]:
n e = 60 p · f
where n e and p are mechanical rotational speed and number of pole pairs, respectively. From Equations (3) and (4), it is evident that increases in electrical frequency f significantly raise iron loss, thereby degrading motor efficiency and increasing thermal stress. Equation (5) further reveals that for a given mechanical speed, electrical frequency is directly proportional to the number of pole pairs. Therefore, to minimize iron loss and improve motor efficiency, high speed motors are typically designed with a reduced number of pole pairs. To guarantee mechanical strength, HSPMSM rotors are commonly fitted with high-strength metallic sleeves as shown in Figure 2, yet high-frequency harmonics induce substantial loss in the sleeve and core, triggering severe heating and magnet overheating. For a HSPMSM with 20 kW and 80,000 rpm, rotor loss reach 300 W to 500 W, driving magnet temperatures over 180 °C; thus, high-temperature samarium-cobalt (SmCo) magnets rated for 250 °C to 300 °C are widely adopted to address this issue.
Figure 2. Schematic Diagram of HSPMSMs.

2.2. Segmented Rotor Analysis

Rotor eddy current losses are intrinsically governed by both the electrical resistivity and geometric thickness of the constituent materials. In engineering practice, axial segmentation of the rotor is widely adopted as an effective countermeasure to mitigate such losses [24]. To quantitatively evaluate this suppression effect, this paper employs three dimensional finite element (3D FE) electromagnetic field simulations. The simulation results reveal that the eddy current loss of an integral (unsegmented) rotor exceeds 500 W. Axially segmenting the rotor sleeve, combined with the incorporation of insulating layers, effectively disrupts the axial eddy current path and drastically attenuates the loss. As illustrated in Figure 3, the incremental reduction in eddy current losses becomes negligible once the rotor is divided into more than four segments. Consequently, a four segment rotor configuration is deemed sufficient to fulfill the practical engineering requirements for high speed motor applications. The aforementioned analysis is conducted within a 3D transient electromagnetic simulation framework. A mesh independence verification was also conducted, as presented in Table 1. In this model, the retaining sleeve is composed of Inconel 718 with an electrical conductivity of 1.1 × 10 6 S/m, while the rotor employs SmCo26HE permanent magnets featuring a conductivity of 6.25 × 10 5 S/m. The adjacent segmented magnets are bonded using an insulating adhesive, which serves the dual purpose of mechanical fixation and electrical isolation.
Figure 3. The simulation of segmented rotor. (a) Integral Rotor (b) Four-Segment Rotor (c) Loss trend versus number of segments.
Table 1. Grid independence verification results.

2.3. Harmonic Analysis Under No-Load Conditions

Electromagnetic torque in electrical machines mainly originates from the fundamental magnetic field, while abundant harmonic components induce additional losses, mechanical vibration and acoustic noise, especially in ultra high speed motors. As a result, harmonic suppression—specifically, minimizing the distortion of the magnetic field waveform—is a critical consideration in the design of such motors. This study focuses on the effect of the slot-to-pole ratio on harmonic content. Given that the number of pole pairs p = 1 in this design, the impact of varying stator slot counts can be directly analyzed. The number of slots per pole per phase is defined by:
Z ′ = Z 2 m p
where Z, m and p are total number of stator slots, number of stator phases and number of pole pairs, respectively. Increasing the number of slots per pole per phase (SPP) facilitates a more optimal stator winding distribution, thereby effectively mitigating armature magnetic field harmonics. To determine the optimal slot-pole combination, this section presents the harmonic spectra under no-load conditions. In this comparative analysis, the stator outer diameter, axial length, and rotor structure are maintained constant; only the slot number and slot geometry are varied. Consequently, four pole-slot combination schemes are established for the motor, namely, 6-slot/2-pole, 12-slot/2-pole, 18-slot/2-pole, and 24-slot/2-pole configurations, corresponding to SPP values ranging from 1 to 4. It is noteworthy that all other design parameters-including rated power, torque output, air gap length, current density, supply voltage, and cooling system specifications-re strictly preserved across all schemes to ensure a fair and consistent comparison.
Under no-load conditions, the radial electromagnetic forces in electrical machines predominantly arise from the interaction between the fundamental magnetic field established by the main poles and the harmonic components introduced by the stator teeth-commonly referred to as tooth harmonics. These force harmonics constitute a major source of vibration and acoustic noise, particularly in high speed motor applications. The no-load radial force can be quantitatively evaluated using the Maxwell stress tensor method. The motor analyzed in this section features an inner-rotor radial-flux topology, and the axial end-leakage flux is neglected to facilitate a two-dimensional air gap field analysis. The air gap magnetic field is described in a cylindrical coordinate system ( r ,   θ ) . Given that the electric field energy is negligibly small compared with the magnetic field energy, only the magnetic stress component is taken into account. Accordingly, the radial normal stress component of the Maxwell stress tensor is equivalent to the radial electromagnetic force density per unit area acting on the stator inner surface:
F r ( θ ,   t ) = B r 2 ( θ ,   t ) − B t 2 ( θ ,   t ) 2 μ 0
where F r denotes the radial electromagnetic force density per unit air gap area in N/m 2 , B r and B t represent the radial and tangential components of the air gap flux density in T, respectively, μ 0 is the vacuum permeability ( 4 π × 10 − 7 H/m), θ denotes the mechanical circumferential angle in radians, and t represents the time in seconds. Under no-load conditions, the stator winding current is zero, and the excitation magnetic field in the air gap is exclusively generated by the rotor permanent magnets. The corresponding radial and tangential flux density components can be expressed via the Fourier series decomposition as follows:
B r 0 ( θ ,   t ) = ∑ v = 1 , 3 , 5 , … B r v cos ( v p θ − v ω e t − φ r v ) B t 0 ( θ ,   t ) = ∑ v = 1 , 3 , 5 , … B t v sin ( v p θ − v ω e t − φ t v )
where v is the spatial harmonic order of the rotor permanent magnet field; p denotes the number of pole pairs (specifically, p = 1 for the proposed 18-slot/2-pole HSPMSM); ω e is the electrical angular velocity in rad/s; B r v and B t v represent the amplitudes of the radial and tangential flux densities of the v-th PM harmonic, respectively; and φ r v and φ t v denote the corresponding initial phase angles of the radial and tangential PM flux density harmonics. Stator slotting periodically modulates the effective air gap length; consequently, the air gap permeance constitutes a spatial periodic function and can be expanded into a Fourier series as:
Λ ( θ ) = Λ 0 + ∑ k = 1 ∞ Λ k cos ( k Z 1 θ )
Considering the slotting effect, the actual modulated air gap flux density is obtained by multiplying the ideal PM flux density by the permeance function, which is expressed as:
B r 0 , Λ ( θ ,   t ) = B r 0 ( θ ,   t ) · Λ ( θ ) B t 0 , Λ ( θ ,   t ) = B t 0 ( θ ,   t ) · Λ ( θ )
Substituting the slot-modulated flux density into Equation (7), for engineering analysis, the quadratic term of the small slot harmonic amplitude Λ k 2 is negligible, and the squared permeance function Λ 2 ( θ ) can be approximated as:
Λ 2 ( θ ) ≈ Λ 0 2 + 2 Λ 0 ∑ k = 1 ∞ Λ k cos ( k Z 1 θ )
where Λ 0 denotes the average air gap permeance, Λ k represents the amplitude of the k-th slot harmonic permeance, k is the order of the slot permeance harmonic, and Z 1 is the total number of stator slots. Consequently, the full expression of the no-load radial force density is derived as:
F r 0 ( θ ,   t ) = Λ 0 2 2 μ 0 ( B r 0 2 − B t 0 2 ) + Λ 0 μ 0 ∑ k = 1 ∞ Λ k ( B r 0 2 − B t 0 2 ) cos ( k Z 1 θ )
In this equation, the first term represents the radial force excited by the mutual interaction of the PM magnetic field harmonics under a smooth air gap condition. The second term corresponds to the additional vibration excitation source induced by the stator tooth harmonics, which is the dominant contributor to the no-load acoustic noise of the motor. By applying the fundamental trigonometric identities cos 2 α = ( 1 + cos 2 α ) / 2 and sin 2 α = ( 1 − cos 2 α ) / 2 , the term B r 0 2 − B t 0 2 can be expanded accordingly. The resulting time-varying harmonic terms contain a spatial angle 2 v p θ , thereby yielding the spatial order of the PM self-coupling force waves as:
r 1 = 2 v p
Furthermore, by employing the product-to-sum identity cos A cos B = [ cos ( A + B ) + cos ( A − B ) ] / 2 , the cross-coupling between the PM field harmonics and the slot permeance harmonics generates additional slot-modulated force waves. The spatial order of these force components is determined as:
r 2 = | 2 v p ± k Z 1 |
Substituting the specific design parameters p = 1 and Z 1 = 18 into Equations (13) and (14) reveals that the dominant low-order force waves correspond to the 2nd, 18th, and 20th spatial orders. The experimental data listed in Table 2.
Table 2. Comparison of harmonic orders in No-Load Air Gap flux density and radial force.
The analysis of no-load air gap flux density and harmonics simulation under different pole-slot combination are shows in Figure 4 and Figure 5, and the radial force table can be derived from these results. These radial force components play a critical role in generating electromagnetic vibration and noise, especially in ultra high speed permanent magnet synchronous motors (HSPMSMs). Understanding the origin and magnitude of these harmonics is essential for optimal slot-pole design and vibration suppression.
Figure 4. Analysis of No-Load Air Gap flux density. (a) 6 slots and 2 poles. (b) 12 slots and 2 poles. (c) 18 slots and 2 poles. (d) 24 slots and 2 poles.
Figure 5. Harmonics simulation under Different Pole-Slot combination.
According to the Maxwell stress tensor, the radial force density in electrical machines comprises multiple spatial harmonics that rotate over time, generating periodic radial vibrations and noise—a primary source of electromagnetic vibration and acoustic noise in high speed inner-rotor motors. Based on air gap flux density harmonic analysis and the derived formulas, Table 2 identifies the fundamental field harmonics r 1 and slot harmonics r 2 , with the low-order force waves from their interaction obtained via r 1 ± r 2 . As shown in Table 2, under no-load conditions, when the number of slots per pole per phase (SPP) equals 1, the waveform of the main pole magnetic field approximates a rectangular shape, resulting in substantial harmonic content. This leads to the generation of low-order radial force waves. Referring to the vibration modes illustrated in Figure 6, these low-order force components align with the natural frequencies of the stator’s lower-order vibration modes. Consequently, electromagnetic excitation in this range readily induces mechanical resonance in the stator structure. In contrast, when SPP ≥ 2 , the no-load air gap flux density waveform approaches a sinusoidal shape. This improvement in magnetic field quality shifts the dominant tooth harmonic components to higher spatial orders, resulting in high-order radial force waves. These high-order components generally do not align with the natural frequencies of the stator’s low-order vibration modes, thereby significantly reducing the likelihood of resonant excitation and minimizing vibration and noise.
Figure 6. The analyze of radial force mode shape.

2.4. Harmonic Analysis Under Load Conditions

Under load conditions, the stator windings are excited by three-phase alternating currents, which introduces an armature reaction magnetic field that superimposes onto the permanent magnet field. It is noteworthy that both the Maxwell stress tensor formulation in Equation (7) and the slot-modulated permeance function remain valid for this operating state. However, the radial force waves in PMSMs originate not only from the interaction between the main field and stator tooth harmonics, but also from the armature reaction field excited by the stator currents. Consequently, by applying trigonometric product-to-sum identities to the electromagnetic field interactions, several additional radial force components are introduced under load conditions. The spatial harmonic orders of the armature magnetic field are derived as follows:
n = ( 6 k + 1 ) p
where k and p are a non-negative integer and number of pole pairs, respectively. As indicated by Equation (15), the superposition of the armature reaction field with the rotor’s main magnetic field generates numerous additional harmonic components. The analysis of no-load air gap flux density and harmonics simulation under different pole-slot combination are shows in Figure 7 and Figure 8. These interactions significantly increase the number of radial force wave components compared to the no-load condition, thereby amplifying the electromagnetic excitation spectrum. This increase in electromagnetic excitation enhances the potential for vibration and noise, particularly if any of the new force wave frequencies coincide with the natural frequencies of the stator structure. Thus, harmonic suppression and optimal electromagnetic design are even more critical in loaded operating scenarios to avoid resonance and ensure quiet, stable operation.
Figure 7. Analysis of Load Air Gap flux density. (a) 6 slots and 2 poles. (b) 12 slots and 2 poles. (c) 18 slots and 2 poles. (d) 24slots and 2 poles.
Figure 8. Harmonics simulation under Different Pole-Slot combination.
Under load conditions, the total air gap flux density is established by the superposition of the permanent magnet (PM) field and the armature reaction field, which can be expressed as:
B r ( θ ,   t ) = B r 0 ( θ ,   t ) + B r a ( θ ,   t ) B t ( θ ,   t ) = B t 0 ( θ ,   t ) + B t a ( θ ,   t )
where B r a and B t a denote the radial and tangential components of the armature reaction flux density, respectively. The armature reaction field components can be decomposed into Fourier series as follows:
B r a ( θ ,   t ) = ∑ u B r u cos ( u p θ + u ω e t − φ r u ) B t a ( θ ,   t ) = ∑ u B t u sin ( u p θ + u ω e t − φ t u )
where u represents the spatial harmonic order of the armature reaction field; B r u and B t u are the amplitudes of the radial and tangential flux density of the u-th armature harmonic, respectively; and φ r u and φ t u denote the corresponding initial phase angles of these components.
For three-phase integer-slot concentrated windings, the spatial harmonic orders of the armature magnetic field satisfy u = ( 6 k ± 1 ) p . By substituting the total air gap flux density from Equation (11) and the slot-modulated permeance function into the Maxwell stress tensor formula defined in Equation (7), the total radial force density under load conditions is expressed as:
F r ( θ ,   t ) = Λ 2 ( θ ) 2 μ 0 ( B r 0 + B r a ) 2 − ( B t 0 + B t a ) 2
Expanding the quadratic bracket yields three physically independent force components. It follows that:
( B r 0 + B r a ) 2 − ( B t 0 + B t a ) 2 = ( B r 0 2 − B t 0 2 ) + ( B r a 2 − B t a 2 ) + 2 ( B r 0 B r a − B t 0 B t a )
Consequently, the total radial force F r is decomposed into the superposition of three distinct terms, as expressed by F r = F r 0 + F r a + F r 0 a . The first term, F r 0 = Λ 2 ( θ ) ( B r 0 2 − B t 0 2 ) / ( 2 μ 0 ) , represents the permanent magnet self-coupling radial force, which is identical to the no-load component derived in Equation (12). The second term, F r a = Λ 2 ( θ ) ( B r a 2 − B t a 2 ) / ( 2 μ 0 ) , corresponds to the armature field self-coupling radial force, which arises from the mutual interaction among different armature magnetic harmonics. The third term, F r 0 a = Λ 2 ( θ ) ( B r 0 B r a − B t 0 B t a ) / μ 0 , denotes the cross-coupling radial force between the permanent magnet field and the armature reaction field. This cross-coupling component is recognized as the dominant newly added vibration excitation source under rated load conditions.
Following the trigonometric product-to-sum transformations applied to the three force components, all possible spatial orders of the load radial force waves can be summarized into a unified analytical expression:
r = | a · 2 v p ± b · 2 u p ± k Z 1 | , a ,   b ∈ { 0 ,   1 }
Within Equation (20), a = 1 ,   b = 0 corresponds to force waves generated by the self-coupling of permanent magnet harmonics, whereas a = 0 ,   b = 1 corresponds to those generated by the self-coupling of armature reaction harmonics. The case a = 1 ,   b = 1 represents the force waves arising from the cross-coupling between the PM and armature harmonics. Additionally, the term ± k Z 1 signifies the extra spatial orders introduced by the stator slot permeance modulation.
Compared with the no-load operating state, the cross-coupling term 2 v p + 2 u p gives rise to abundant new low-order force wave components, which significantly intensify the radial electromagnetic excitation. This is consistent with the harmonic order data listed in Table 3.
Table 3. Comparison of harmonic orders in load Air Gap flux density and radial force.
Table 4 presents the harmonic content of the air gap flux density under different slot-pole combinations. A higher harmonic content leads to stronger radial force waves due to increased electromagnetic interaction, which in turn results in elevated levels of vibration and acoustic noise and the eddy current loss.
Table 4. Total harmonic distortion of air gap flux density.
It is observed that both the total harmonic distortion (THD) of the air gap flux density and the eddy current losses exhibit a significant reduction as the number of slots per pole per phase (SPP) increases. The minimum values for both metrics are achieved at an SPP of 3, while a further increase to 4 yields no continuous improvement. Considering that higher slot counts inevitably increase manufacturing complexity, the 18-slot/2-pole configuration is ultimately selected as the optimal compromise between fabrication feasibility and electromagnetic performance. By integrating the preceding radial force analysis with the THD evaluation, it is evident that an SPP of 3 effectively circumvents the emergence of low-order spatial radial force waves while substantially mitigating air gap field harmonics, thereby suppressing motor vibration and acoustic noise. Consequently, this study adopts the 18-slot/2-pole pole-slot combination, a configuration that offers a well-balanced trade-off across rotor harmonic suppression, loss minimization and radial force attenuation [24].

2.5. Analysis of Different Magnetization Methods

With rotor geometry and magnet material fixed, magnetization direction governs the main magnetic field. Considering mechanical strength and magnetization feasibility, an integral magnetic-pillar rotor is adopted to regulate permanent magnet flux orientation. Figure 9a illustrates various magnetization strategies for rotor-mounted magnet rings. Focusing on the integral permanent magnet structure as the analysis object, radial magnetization results in a main pole magnetic field that closely resembles a rectangular waveform. After applying Fourier decomposition, the harmonic spectrum—shown in Figure 9b—reveals that the dominant harmonic orders follow the pattern 2(r + 1)p, where r is an integer and p is the number of pole pairs. This yields prominent harmonic components at the 3rd, 5th, 7th, 9th, and 11th orders, all of which contribute negatively to motor performance by increasing core losses, heating, vibration, and noise. For a magnetic pillar rotor structure with non-uniform magnet thickness, employing parallel magnetization enables a flux-focusing effect. In this configuration, the magnetization direction aligns with the primary flux path, resulting in a sinusoidal magnetic field distribution. This leads to a higher peak air gap flux density, significantly reduced harmonic content, and improved utilization of the permanent magnet material. Figure 9c presents the measured surface magnetic field waveform of a parallel-magnetized magnetic pillar rotor, which clearly exhibits near-ideal sinusoidal characteristics with minimal harmonic distortion. Halbach magnetization concentrates magnetic flux in the air gap to form a unidirectional field and an approximately sinusoidal flux waveform. Nevertheless, it demands precise magnetic domain alignment, leading to complicated fabrication. Segmented approximation further raises manufacturing difficulty and weakens rotor mechanical reliability. Therefore, Halbach magnetization is excluded from the scope of this study.
Figure 9. The regulate permanent magnet flux orientation. (a) Common magnetizing methods for permanent magnets. (b) Air Gap flux density rectangular wave and Fourier analysis. (c) Measured air gap flux density waveform.

3. Thermal Management and Structure Strength Analysis

3.1. Thermal Management

This paper adopts a motor configuration of 18 slots and 2 poles, with the following rated specifications in Table 5.
Table 5. The parameter of this HSPMSM.
Based on comprehensive loss calculations and thermal management simulations, the thermal performance of the high speed electric machine is illustrated in Figure 10. Table 6 and Table 7 presents thermal boundary conditions, heat transfer coefficients and relevant parameters of cooling medium. Under the proposed thermal management scheme, the heat dissipation process primarily relies on two paths: stator-to-housing thermal conduction via an interference fit, where an internal water-cooling jacket actively extracts the heat, and rotor-stator air gap convection, where the gas flow generated by the centrifugal compressor provides effective cooling for both the stator windings and the rotor permanent magnets. According to the preceding electromagnetic analysis, the rated losses—comprising 550 W of copper loss, 140 W of core loss, and 30 W of rotor eddy current loss—are assigned to their respective components after applying appropriate distribution correction factors. The steady-state thermal network simulation at rated conditions yields the following results: the maximum winding temperature is 174 °C, corresponding to a calculated temperature rise of 95 K above the 70 °C ambient condition; the actual measured winding temperature reaches 165 °C, yielding a deviation of approximately 5% from the theoretical prediction, which comfortably stays within the 180 °C limit designated for Class H insulation. Additionally, the rotor sleeve temperature is maintained at 160 °C, which is well within the safe operating range for stainless steel, while the permanent magnet temperature reaches 170 °C, remaining significantly below the 250 °C thermal capability of the samarium cobalt magnets, thereby confirming the thermal robustness of the rotor magnetic assembly.
Figure 10. Simulation of thermal management for the HSPMSM. (a) The radial temperature display. (b) Axial temperature display. (c) Temperature evolution.
Table 6. Stator Housing Water Cooling Parameters.
Table 7. Rotor Air Cooling Parameters.

3.2. Rotor Analysis

At ultra high speeds, severe centrifugal force may induce structural failure of the rotor and bring potential mechanical hazards [25]. To address this, a monolithic magnetic pole structure with an outer stainless steel retaining sleeve is adopted to guarantee rotor mechanical reliability under high speed operation. Inconel 718 nickel-based alloy is selected as the material of the retaining sleeve. Structural simulation is conducted for verification. Figure 11a presents the rotor assembly with a 0.06 mm unilateral interference fit between the sleeve and magnetic poles, while Figure 11c shows the stress distribution at 120,000 rpm. The key results are:
Figure 11. The rotor schematic diagram of ultra-high-speed PMSMs and simulation analysis. (a) Schematic diagram of rotor. (b) Rotor deformation analyze. (c) Rotor stress analyze.
  • Maximum sleeve stress: 856 MPa—below the 1275 MPa tensile strength of stainless steel. The mechanical stress safety factor is greater than 1.4.
  • Magnet stress: 30 MPa (tensile)/50 MPa (compressive)—both below the 70 MPa limit of samarium cobalt magnets-SmCo26HE. The mechanical stress safety factor is greater than 2.33.
All critical stress values remain within material strength limits, confirming the structural reliability of the rotor under maximum speed operation.
It can be seen from Table 8 that the retaining sleeve material retains high strength from ultra low temperature (−250 °C) to medium-high temperature (700 °C), satisfying the demand of extreme environmental conditions.
Table 8. Variation of Mechanical Properties of Inconel 718 with Temperature.
Figure 11b presents the simulated deformation results of the rotor assembly under high speed operation. The diametral interference magnitude between the rotor retaining sleeve and permanent magnetic poles ranges from 0.1 mm to 0.12 mm. The shrink-fitting process is adopted with a shrink-fitting temperature of 650 °C. The analysis reveals a radial expansion of 0.0587 mm in the stainless steel sleeve and a slight inward deformation of 0.001 mm in the permanent magnets. The combined deformation of 0.0597 mm closely aligns with the initial 0.06 mm interference fit, indicating that the fit remains effectively intact even under extreme centrifugal forces. Importantly, a contact stress of 80 MPa is maintained between the sleeve and the magnets, ensuring continued mechanical engagement and structural coherence at maximum speed. This residual contact pressure confirms the reliability of the interference fit and the overall integrity of the rotor design. High speed motor rotors are slender and prone to bending deformation; material non-uniformity, machining and assembly errors also induce rotor eccentricity. Excessive eccentricity enlarges rotor deflection, and resonance arises when the rotational frequency approaches the first-order natural frequency, deteriorating stability, vibration and noise performance. Modal analysis in Figure 12 gives a first-order natural frequency of 6428 Hz, corresponding to a critical speed of 385,680 rpm. As the maximum operating speed of 120,000 rpm is far lower than this critical speed, resonance is effectively avoided across the full operating range.
Figure 12. Rotor model analysis.
Beyond critical speed evaluation, comprehensive rotor dynamic analysis must also incorporate the effects of gyroscopic moments and rotational damping, especially in high-speed regimes. The general form of the governing formula of motion for rotor dynamics is given by:
F = [ M ] [ U ″ ] + [ C ] [ U ′ ] + [ K ] [ U ]
where F ,   U ,   M ,   C ,   K are external force vector, displacement vector, mass matrix, damping matrix and stiffness matrix, respectively. To account for gyroscopic coupling and spin softening effects, the formula is reformulated as:
F = [ M ] [ U ″ ] + { [ C ] + [ G ] } [ U ′ ] + { [ K ] + [ B ] } [ U ]
where G ,   B are gyroscopic effect matrix and spin softening matrix, respectively. This modified formula comprehensively models the dynamic behavior of the rotor by describing the interaction between external forces, inertial effects, damping, stiffness, and rotational dynamics.
This study conducts a comprehensive rotor dynamics analysis of the electric motor by examining the 1st to 6th modal orders and performing dynamic simulations across the full operating range from 0 to 130,000 rpm. The results are illustrated in Figure 13 as a Campbell diagram. Figure 14 presents air bearings stiffness and parameters. Modal analysis in Figure 13 reveals that the first six natural frequencies vary slightly with speed, demonstrating high rotor rigidity and negligible softening effect. The first bending mode avoids overlap with excitation frequency, keeping the critical speed far above the operating range. This chapter elaborates the HSPMSM thermal and structural design via simulations. Winding and magnet temperature rises, as well as rotor mechanical stress, remain within permissible limits, validating thermal performance and structural integrity. Rotor dynamic analysis further verifies resonance avoidance throughout the speed range for stable high speed operation.
Figure 13. Campbell Diagram of rotor dynamics.
Figure 14. Air bearings stiffness and parameters.

4. Electric Machine Testing and Performance Analysis

4.1. Electric Machine Testing and Performance Analysis

The high speed rotor assembly of the air compressor undergoes precision dynamic balancing calibration. The rotor has a total mass of 1.28 kg and and this is presented in Figure 15. Based on this mass, the rotor requires a balance grade of G1, which corresponds to a high precision balance level for ultra high speed rotating machinery. The target design operating speed is 99,999 rpm. A symmetrical tolerance allocation scheme is applied to the two correction planes. The allowable residual unbalance tolerance is set to 0.06 g·mm for each plane. The balancing test is conducted at a verification speed of 2403 rpm. The measured residual unbalance of the two correction planes is 46.0 mg·mm at phase 302° and 12.5 mg·mm at phase 272°, respectively. These values are both well below the allowable tolerance threshold. Consequently, the corresponding mass correction values for material removal are 1.84 mg at phase 302° and 0.417 mg at phase 272°, respectively. This extremely low residual unbalance after calibration effectively suppresses vibration excitation under ultra high speed operation. It also reduces dynamic bearing loads and operating noise. Therefore, the balancing process provides a reliable mechanical foundation for stable rotor operation at speeds approaching 100,000 rpm.
Figure 15. Dynamic balancing test.
Design and development of an 18-slot/2-pole HSPMSM for fuel cell centrifugal compressors is presented. This motor achieves 35 kW rated power at 100,000 rpm, featuring a rotor structure with high-strength stainless steel sleeve, parallel-magnetized solid cylindrical magnets, and air bearings for low-friction high speed performance.
Key design parameters are summarized in Table 9. Figure 16 shows the overall design and partial details of the HSPMSM, where Figure 16a shows the prototype of the centrifugal air compressor, Figure 16b presents the stator of HSPMSM and Figure 16c illustrates the rotor of HSPMSM.
Table 9. Required motor parameters.
Figure 16. Prototype of the centrifugal air compressor with HSPMSM. (a) The centrifugal compressor. (b) The stator of HSPMSM. (c) The Rotor for HSPMSM.

4.2. Motor Performance

Figure 17a simulates the 18-slot/2-pole parallel-magnetized motor with a metal retaining sleeve, yielding stator tooth flux density of 0.8–0.9 T and yoke flux density of 0.6–0.7 T, achieving high magnetic utilization without saturation. Figure 17b provides the motor efficiency map, with a peak efficiency of 97.6%. The high-efficiency region (over 95%) covers 2–3 Nm and 3000–100,000 rpm, fully encompassing the rated operating point and validating practical efficiency performance. The motor features a back-EMF coefficient of 2.99 V/kRPM. Figure 17c shows an ideally sinusoidal back-EMF waveform with low harmonic distortion, which ensures smooth torque output and reduces acoustic noise. Key results for no-load radial force waveforms are provided in Table 10. Key results for load radial force waveforms are provided in Table 11. Radial force analysis agrees with Section 2, where the 20th spatial order dominates the force spectrum. Loaded radial force amplitude is markedly higher than under no-load conditions. The 18-slot/2-pole topology effectively suppresses low-order radial forces to reduce vibration and noise, well matching theoretical expectations.
Figure 17. (a) Electromagnetic configuration schematic. (b) Efficiency map. (c) Simulation b EMF / K e = 2.99 V / krpm .
Table 10. Values of noload radial Force for different time and space orders.
Table 11. Values of load radial Force for different time and space orders.

4.3. Experimental Validation

Figure 18 displays the measured back-EMF waveform of the manufactured motor prototype. The back-EMF exhibits excellent sinusoidal characteristics with low harmonic distortion. The measured back-EMF constant is 2.8 V/kRPM, which is in good agreement with the theoretical value with a deviation of only 6%, thus verifying the accuracy of the electromagnetic design. In addition, other measured motor parameters are listed in Table 12. As illustrated in Figure 19, the proposed design yields a superior efficiency for the air compressor. Figure 20 further verifies that the system operates free from resonance throughout the entire speed range.
Figure 18. Prototype B_EMF/ K e is 2.8 V/Krpm.
Table 12. Measured motor parameters.
Figure 19. Measured System Efficiency of Air Compressor.
Figure 20. Measured noise levels of the air compressor at different rotational speeds.

4.4. Reliability Verification of the Air Compressor

The endurance test was conducted under a cyclic operating profile comprising four successive stages: acceleration from zero speed to idle speed, a holding period, acceleration from idle speed to maximum speed, another holding period, and a subsequent shutdown. Specifically, the acceleration times to idle speed and maximum speed are maintained below 1 s and 3 s, respectively, with a 2 s holding duration applied after each acceleration stage, while the shutdown phase is completed within 10 s. As shown in Figure 21, following 100,000 consecutive start-stop cycles, the air compressor continued to operate normally without any observed faults. Post-test measurements confirmed that all dynamic response times—including the start-up time (zero to idle speed), loading time (idle to maximum speed), and shutdown time—remained strictly within the aforementioned thresholds. Based on these satisfactory test results, the air compressor was deemed to have successfully passed the qualification criteria.
Figure 21. Start-stop test.
This study optimizes the slot-pole combination to suppress noise and eddy current loss, while rotor segmentation further reduces losses and improves efficiency. The parallel magnetized pole structure enhances flux concentration and air gap flux density, boosting output power within limited dimensions. A well designed rotor configuration also guarantees stable operation, satisfying the high power density demands of air compressor applications.

5. Conclusions

Fuel cell technology advancement raises the demand for high speed air compressor motors. This paper investigates the key design aspects of an HSPMSM for fuel cell centrifugal compressors and draws the following conclusions:
  • Pole-slot combination strongly affects harmonic losses and NVH performance; the three-slots-per-pole-per-phase configuration optimally suppresses low-order harmonics and improves vibration behavior.
  • Rotor segmentation effectively reduces core losses, with four-segment structure achieving the best balance of performance and manufacturability.
  • Magnetization mode greatly affects air gap flux density. The use of monolithic magnet poles with parallel magnetization is recommended, as it effectively suppresses harmonic distortion while improving magnetic flux utilization.
  • The adoption of a high-strength stainless steel retaining sleeve significantly enhances rotor structural integrity under extreme centrifugal forces.
Based on the proposed design, a prototype motor was developed and analyzed in terms of thermal, electromagnetic, mechanical, and dynamic characteristics. Experimental results show that the winding and permanent magnet temperatures remain within safe operating limits, the maximum operating speed is well below the first critical speed, and the rotor stresses satisfy the material strength requirements. The prototype fabrication and testing verify the feasibility and reliability of the proposed design scheme.

Author Contributions

Conceptualization, Z.S.; methodology, Z.S.; software, Z.S.; validation, J.H.; formal analysis, Z.S.; investigation, Z.S.; resources, Z.S.; data curation, Z.S.; writing—original draft preparation, Z.S.; writing—review and editing, Z.S. and G.W.; visualization, Z.S. and W.T.; supervision, J.H.; project administration, Z.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The original contributions presented in the study are included in the article. Further inquiries can be directed to the corresponding author.

Acknowledgments

The authors sincerely thank Zijie Xu and Beijing Bolken Energy Technology Inc. for providing essential experimental data and key technical parameters. Their valuable support greatly facilitated the experimental verification and research improvement of this work.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Cappiello, A.; Ciais, V.; Pini, M. A Multi-Point Preliminary Design Method for Centrifugal Compressor Stages of Fuel Cell-Based Propulsion Systems. Int. J. Turbomach. Propuls. Power 2025, 10, 39. [Google Scholar] [CrossRef] [Scilit]
  2. Wang, Z.; Zhao, R.; Zhu, Z.; Zhuge, W.; Zhang, Y. A novel multi-objective optimization scheme of electric turbo compressor system in hydrogen fuel cell. Energy 2024, 309, 133096. [Google Scholar] [CrossRef] [Scilit]
  3. Xing, J.; Xu, Y.; Zhang, J.; Li, Y.; Jiang, X. A Reliable and Efficient I-f Startup Method of Sensorless Ultra-High-Speed SPMSM for Fuel Cell Air Compressors. Actuators 2024, 13, 203. [Google Scholar] [CrossRef] [Scilit]
  4. Zhao, W.; Wang, X.; Gerada, C.; Zhang, H.; Liu, C.; Wang, Y. Multi-Physics and Multi-Objective Optimization of a High Speed PMSM for High Performance Applications. IEEE Trans. Magn. 2018, 54, 8106405. [Google Scholar] [CrossRef] [Scilit]
  5. He, T.; Zhu, Z.Q.; Xu, F.; Bin, H.; Wu, D.; Gong, L.; Chen, J. Comparative Study of 6-Slot/2-Pole High-Speed Permanent Magnet Motors with Different Winding Configurations. IEEE Trans. Ind. Appl. 2021, 57, 5864–5875. [Google Scholar] [CrossRef] [Scilit]
  6. Iida, T.; Takemoto, M.; Ogasawra, S.; Orikawa, K.; Sato, I.; Kokubun, H.; Toba, A.; Syuto, M. Investigation of Enhancing Output Power Density in Ultra-High-Speed Motors with Concentrated Winding Structure. In Proceedings of the 2020 IEEE Energy Conversion Congress and Exposition (ECCE), Detroit, MI, USA, 11–15 October 2020; pp. 262–269. [Google Scholar] [CrossRef] [Scilit]
  7. Kim, J.-H.; Im, S.-Y.; An, S.-M.; Cha, K.-S.; Lim, M.-S. Comparative Study of Various Slot Pitches for 2-Pole 6-Slot Ultra-high-Speed Permanent Magnet Synchronous Motors. IEEE Trans. Magn. 2023, 59, 8202505. [Google Scholar] [CrossRef] [Scilit]
  8. Pu, T.; Du, G.; Tong, J.; Huang, N.; Li, N.; Xu, W. Comparison of Rotor Strength of Various Rotor Structures for Ultra-high-speed Permanent Magnet Synchronous Motor. In Proceedings of the 2021 IEEE 4th Student Conference on Electric Machines and Systems (SCEMS), Huzhou, China, 1–3 December 2021; pp. 1–6. [Google Scholar] [CrossRef] [Scilit]
  9. Krasopoulos, C.T.; Ioannidis, A.S.; Kremmydas, A.F.; Karafyllakis, I.A.; Kladas, A.G. Convection Heat Transfer Coefficient Regression Models Construction for Fast High-Speed Motor Thermal Analysis. IEEE Trans. Magn. 2022, 58, 8206905. [Google Scholar] [CrossRef] [Scilit]
  10. Credo, A.; Fabri, G.; Villani, M.; Popescu, M. Adopting the Topology Optimization in the Design of High-Speed Synchronous Reluctance Motors for Electric Vehicles. IEEE Trans. Ind. Appl. 2020, 56, 5429–5438. [Google Scholar] [CrossRef] [Scilit]
  11. Ou, J.; Liu, Y.; Doppelbauer, M. Comparison Study of a Surface-Mounted PM Rotor and an Interior PM Rotor Made From Amorphous Metal of High-Speed Motors. IEEE Trans. Ind. Electron. 2021, 68, 9148–9159. [Google Scholar] [CrossRef] [Scilit]
  12. Wang, L.; Wu, Y.; Guo, Y.; Feng, J.; Peng, X. Analysis of the cooling performance based on the three-dimensional magnetic-thermal coupling in high-speed permanent magnet synchronous motor. J. Traffic Transp. Eng. (Engl. Ed.) 2025, 12, 1397–1414. [Google Scholar] [CrossRef] [Scilit]
  13. Xing, E.; Gao, Q.; Dong, Y.; Bai, W. Design and Optimization of Support and Drive System for Magnetic Levitation Air Compressor for Fuel Cells. Actuators 2025, 14, 26. [Google Scholar] [CrossRef] [Scilit]
  14. Zhang, H. Design and research of an ultra-high speed centrifugal air compressor for hydrogen fuel cell aircraft. Int. J. Interact. Des. Manuf. 2025, 19, 8381–8394. [Google Scholar] [CrossRef] [Scilit]
  15. Fodorean, D. High-Speed Electric Motors for Fuel Cell Compressor System Used for EV Application—Review and Perspectives. Appl. Sci. 2026, 16, 476. [Google Scholar] [CrossRef] [Scilit]
  16. Guo, Y.; Yang, X.; He, L.; Ju, Q.; Hou, Y.; Chen, S. Experimental study on expanding the efficient operating range of two-stage series high-speed centrifugal air compressors. Case Stud. Therm. Eng. 2025, 75, 107144. [Google Scholar] [CrossRef] [Scilit]
  17. Lee, M.S.; Kang, S.H.; Lee, S.G.; Yoon, Y.D. Identification of D–q inductances and initial rotor position in high-speed motors for fuel-cell air compressors in consideration of voltage distortions. J. Power Electron. 2025, 25, 1855–1865. [Google Scholar] [CrossRef] [Scilit]
  18. Zhang, Q.; Yang, D.; Kong, Q.; Sun, X.; Hu, Z. A super-high-speed PM motor drive for centrifugal air compressor used in fuel cell unmanned aerial vehicle. IET Electr. Power Appl. 2023, 17, 1459–1468. [Google Scholar] [CrossRef] [Scilit]
  19. Zhong, S.; Ou, K.; Jin, Z.; Zhang, Q.; Zhang, X.; Wang, Y.-X. Improved optimal sliding mode control and operating strategy for turbine-based air compressor in automotive fuel cells with driving cycles analysis. Energy 2025, 324, 135743. [Google Scholar] [CrossRef] [Scilit]
  20. Shen, Q.; Zhou, Z.; Li, S.; Liao, X.; Wang, T.; He, X.; Zhang, J. Design and Analysis of the High-Speed Permanent Magnet Motors: A Review on the State of the Art. Machines 2022, 10, 549. [Google Scholar] [CrossRef] [Scilit]
  21. Tian, Y.; Liang, S.; Wang, F.; Tian, J.; Chen, K.; Liu, S. Analysis of Rotor Lamination Sleeve Loss in High-Speed Permanent Magnet Synchronous Motor. Machines 2025, 13, 236. [Google Scholar] [CrossRef] [Scilit]
  22. Uzhegov, N.; Kurvinen, E.; Nerg, J.; Pyrhönen, J.; Sopanen, J.T.; Shirinskii, S. Multidisciplinary Design Process of a 6-Slot 2-Pole High-Speed Permanent-Magnet Synchronous Machine. IEEE Trans. Ind. Electron. 2016, 63, 784–795. [Google Scholar] [CrossRef] [Scilit]
  23. Yi, F.; Su, Q.; Feng, C.; Wang, X.; Yang, L.; Zhou, J.; Fan, Z.; Jiang, S.; Zhang, Z.; Yu, T.; et al. Response Analysis and Stator Optimization of Ultrahigh-Speed PMSM for Fuel Cell Electric Air Compressor. IEEE Trans. Transp. Electrif. 2023, 9, 5098–5110. [Google Scholar] [CrossRef] [Scilit]
  24. Du, G.; Zhou, Q.; Liu, S.; Huang, N.; Chen, X. Multiphysics Design and Multiobjective Optimization for High-Speed Permanent Magnet Machines. IEEE Trans. Transp. Electrif. 2020, 6, 1084–1092. [Google Scholar] [CrossRef] [Scilit]
  25. Shao, Y.; Wang, X.; Gao, Q.; Li, Y. Rotor Strength Analysis of Ultra-High Speed Permanent Magnet synchronous Motor. In Proceedings of the 2019 22nd International Conference on Electrical Machines and Systems (ICEMS), Harbin, China, 11–14 August 2019; pp. 1–4. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics